AD FD PROJECT NAME: OCEAN FRONT WALK ADDRESS: 1659 OCEAN FRONT WALK SANTA MONICA, CA 90401 OWNER: WILSHIRE SKYLINE PROJECT DESCRIPTION: REPLACEMENT OF NON-HISTORIC SLIDING WINDOWS WITH SINGLE HUNG FIBERGLASS WINDOWS. LOT SIZE: 4,975 SF BUILDING SF: 15,790 SF BLDG HEIGHT: +/- 48' - 2" NUMBER OF STORIES: 4 OCCUPANCY TYPE: R2 PROJECT INFORMATION 2013 CALIFORNIA BUILDING CODE BASED ON 2012 INTERNATIONAL BUILDING CODE 2013 CALIFORNIA ELECTRICAL CODE BASED ON 2012 NATIONAL ELECTRICAL CODE 2013 CALIFORNIA MECHANICAL CODE BASED ON 2012 UNIFORM MECHANICAL CODE 2013 CALIFORNIA PLUMBING CODE BASED ON 2012 UNIFORM PLUMBING CODE 2016 CALIFORNIA ENERGY CODE, TITLE 24, PART 6 BUILDING CODES USED PROJECT TEAM OWNER WILSHIRE SKYLINE 1775 N. ORANGE DR, SUITE 100 LOS ANGELES, CA 90028 323.651.1000 ALAN TZVIKA NISSEL ARCHITECT OMGIVNING 724 S SPRING ST #501 LOS ANGELES, CA 90014 213.596.5602 ROBERTO VAZQUEZ SHEET INDEX ARCHITECTURAL SYMBOLS DETAIL BUILDING SECTION WALL SECTION INTERIOR ELEVATION EXTERIOR ELEVATION ELEVATION MARK N13 WINDOW MARK DOOR MARK WALL TYPE WORK POINT NOTE ACCESSIBLE PATH OF TRAVEL FENCE EXIT SIGN ALIGN FINISHES SMOKE DETECTOR FIRE EXTINGUISHER AREA DRAIN FLOOR DRAIN FLOOR MATERIAL TRANSITION SECURITY OPENING PROPERTY LINE 1 A101 1 A101 1 A101 A900 A B C D 1 A101 KK 222.2 1 WPT SD FE FMC SITE: 1659 OCEAN FRONT WALK SANTA MONICA, CA 90401 VICINITY MAP ARCHITECTURAL ABBREVIATIONS DEMOLISH EXISTING NEW AIR CONDITIONING ANCHOR BOLT ACOUSTIC CEILING TILE AMERICANS WITH DISABILITIES ACT ADJACENT ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATELY ARCHITECT BOARD BRACE FRAME BLOCK BEAM BETWEEN CABINET CLOSET CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONTRACTOR CARPET COURSES CERAMIC TILE DISABLED ACCESS DOUBLE DIAMETER DIMENSION DOWN DOWNSPOUT DRAWING ELECTRICAL ELEVATOR EDGE OF SLAB EQUAL EXTERIOR FIRE EXTINGUISHER FINISH FLOOR FINISH FLOOR JOIST FLOOR (D) (E) (N) A/C AB ACT ADA ADJ AFF ALT ALUM APPROX ARCH BD BF BLK BM BTWN CAB CL CLG CLR CMU COL CONC CONT CONTR CPT CRS CT DAS DBL DIA DIM DN DS DWG ELECT ELEV EOS EQ EXT FE FF FIN FJ FLR FLOOR MATERIAL CHANGE FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FIRE RESISTIVE FINISH SURFACE GAUGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GYPSUM BOARD HOSE BIB HOLLOW CORE HOLLOW CORE WOOD DOOR HEADER HOLLOW METAL HANDRAIL HEIGHT INSULATION INTERIOR JOIST LAMINATE LAVATORY LINOLEUM MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED METAL NOTE NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OWNER FURNISHED VENDOR INSTALLED OVERHEAD OPENING PROTECT IN PLACE PLASTIC LAMINATE FMC FOC FOF FOM FOS FR FS GA GALV GB GC GYP BD HB HC HCW HDR HM HR HT INS INT JST LAM LAV LIN MAX MECH MFR MIN MISC MO MTD MTL N NIC NTS OC OFCI OFOI OFVI OH OPNG PIP PLAM PAINT PAINTED QUANTITY RADIUS OR RISER REFLECTED CEILING PLAN ROOF DRAIN REFRIGERATOR REQUIRED REVISION OR REVISED ROOM RIGHT OF WAY RESTROOM SOLID CORE SOLID CORE WOOD SQUARE FEET SHEET SHEATHING SIMILAR SLOPE STAINLESS STEEL STEEL STRUCTURAL THREAD TO BE DETERMINED THRESHOLD THICK TRUSS JOINT TOP OF TOP OF CONCRETE TOP OF PLATE TOP OF SHEATHING TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WATER CLOSET WOOD WATER HEATER WATERPROOF WORK POINT PT PTD QTY R RCP RD REF REQ'D REV RM ROW RRM SC SCW SF SHT SHTG SIM SL ST STL STL STRUCT T TBD TH THK TJ TO TOC TOP TOS TOW TYP UNO VCT VERT VIF W WC WD WH WP WPT THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE COPYRIGHTED WORK OF OMGIVNING ARCHITECTS AND MAY NOT BE REPRODUCED WITHOUT WRITTEN PERMISSION. DATE: SCALE: SHEET TITLE: SHEET NUMBER: JOB NO.: REVISIONS: 1/4" = 1'-0" 6/20/18 11:06:39 AM G000 COVER SHEET OCEAN FRONT WALK 1659 OCEAN FRONT WALK SANTA MONICA, CA 90401 WINDOW REPLACEMENT WILSHIRE SKYLINE LOS ANGELES, CA 90028 1775 N. ORANGE DR, SUITE 100 18-001 G000 COVER SHEET D101 1ST & 2ND DEMOLITION FLOOR PLANS D102 3RD & 4TH DEMOLITION FLOOR PLANS D200 DEMOLITION ELEVATIONS A101 PROPOSED 1ST & 2ND FLOOR PLANS A102 PROPOSED 3RD & 4TH FLOOR PLANS A200 PROPOSED ELEVATIONS A800 WINDOW SCHEDULE AND DETAILS 3-31-19 3-31-19 08.03.18

Transcript of AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col...

Page 1: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

AD

FD

PROJECT NAME: OCEAN FRONT WALK

ADDRESS: 1659 OCEAN FRONT WALKSANTA MONICA, CA 90401

OWNER: WILSHIRE SKYLINE

PROJECT DESCRIPTION: REPLACEMENT OF NON-HISTORICSLIDING WINDOWS WITH SINGLE HUNGFIBERGLASS WINDOWS.

LOT SIZE: 4,975 SF

BUILDING SF: 15,790 SF

BLDG HEIGHT: +/- 48' - 2"

NUMBER OF STORIES: 4

OCCUPANCY TYPE: R2

PROJECT INFORMATION

2013 CALIFORNIA BUILDING CODE BASED ON 2012INTERNATIONAL BUILDING CODE

2013 CALIFORNIA ELECTRICAL CODE BASED ON 2012NATIONAL ELECTRICAL CODE

2013 CALIFORNIA MECHANICAL CODE BASED ON 2012UNIFORM MECHANICAL CODE

2013 CALIFORNIA PLUMBING CODE BASED ON 2012UNIFORM PLUMBING CODE

2016 CALIFORNIA ENERGY CODE, TITLE 24, PART 6

BUILDING CODES USED PROJECT TEAM

OWNERWILSHIRE SKYLINE1775 N. ORANGE DR, SUITE 100LOS ANGELES, CA 90028323.651.1000ALAN TZVIKA NISSEL

ARCHITECTOMGIVNING724 S SPRING ST #501LOS ANGELES, CA 90014213.596.5602ROBERTO VAZQUEZ

SHEET INDEXARCHITECTURAL SYMBOLS

DETAIL

BUILDING SECTION

WALL SECTION

INTERIOR ELEVATION

EXTERIOR ELEVATION

ELEVATION MARK

N13

WINDOW MARK

DOOR MARK

WALL TYPE

WORK POINT

NOTE

ACCESSIBLE PATH OF TRAVEL

FENCE

EXIT SIGN

ALIGN FINISHES

SMOKE DETECTOR

FIRE EXTINGUISHER

AREA DRAIN

FLOOR DRAIN

FLOOR MATERIALTRANSITION

SECURITY OPENING

PROPERTY LINE

1A101

1A101

1A101

A900

A

B

C

D

1A101

KK

222.2

1

WPT

SD

FE

FMC

SITE:1659 OCEAN FRONT WALKSANTA MONICA, CA 90401

VICINITY MAP

ARCHITECTURAL ABBREVIATIONSDEMOLISH EXISTING NEW

AIR CONDITIONINGANCHOR BOLT ACOUSTIC CEILING TILE AMERICANS WITH DISABILITIES ACTADJACENT ABOVE FINISHED FLOOR ALTERNATEALUMINUM APPROXIMATELYARCHITECT

BOARDBRACE FRAME BLOCKBEAMBETWEEN

CABINET CLOSET CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS CONTRACTOR CARPETCOURSESCERAMIC TILE

DISABLED ACCESSDOUBLE DIAMETERDIMENSIONDOWNDOWNSPOUTDRAWING

ELECTRICAL ELEVATOREDGE OF SLAB EQUAL EXTERIOR

FIRE EXTINGUISHERFINISH FLOORFINISH FLOOR JOIST FLOOR

(D) (E) (N) A/CABACT ADA ADJAFFALTALUMAPPROXARCH

BDBFBLKBMBTWN

CABCL CLGCLRCMUCOLCONCCONT CONTRCPTCRSCT

DAS DBLDIADIMDNDSDWG

ELECTELEVEOSEQEXT

FEFFFINFJFLR

FLOOR MATERIAL CHANGEFACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FIRE RESISTIVE FINISH SURFACE

GAUGEGALVANIZED GRAB BAR GENERAL CONTRACTOR GYPSUM BOARD

HOSE BIB HOLLOW CORE HOLLOW CORE WOOD DOOR HEADER HOLLOW METAL HANDRAILHEIGHT

INSULATIONINTERIOR

JOIST

LAMINATE LAVATORY LINOLEUM

MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUSMASONRY OPENINGMOUNTED METAL

NOTE NOT IN CONTRACT NOT TO SCALE

ON CENTEROWNER FURNISHED CONTRACTOR INSTALLED

OWNER FURNISHED OWNER INSTALLED OWNER FURNISHED VENDOR INSTALLED OVERHEAD OPENING

PROTECT IN PLACE PLASTIC LAMINATE

FMCFOCFOFFOMFOS FRFS

GA GALVGBGCGYP BD

HBHC HCWHDR HMHR HT

INSINT

JST

LAMLAV LIN

MAXMECHMFRMINMISCMOMTDMTL

NNICNTS

OCOFCIOFOIOFVIOHOPNG

PIPPLAM

PAINT PAINTED

QUANTITY

RADIUS OR RISER REFLECTED CEILING PLAN ROOF DRAINREFRIGERATORREQUIRED REVISION OR REVISEDROOM RIGHT OF WAY RESTROOM

SOLID CORE SOLID CORE WOOD SQUARE FEET SHEETSHEATHING SIMILAR SLOPESTAINLESS STEEL STEEL STRUCTURAL

THREAD TO BE DETERMINED THRESHOLD THICK TRUSS JOINT TOP OF TOP OF CONCRETE TOP OF PLATE TOP OF SHEATHING TOP OF WALL TYPICAL

UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD

WITH WATER CLOSET WOOD WATER HEATER WATERPROOF WORK POINT

PT PTD

QTY

R RCPRDREF REQ'DREVRMROWRRM

SCSCWSF SHTSHTGSIMSLST STLSTLSTRUCT

TTBDTH THKTJTOTOCTOP TOSTOWTYP

UNO

VCT VERTVIF

W WCWDWHWP WPT

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/4" = 1'-0"

6/20

/18

11:0

6:39

AM

G000

COVER SHEET

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659

OC

EA

N F

RO

NT

WA

LKS

AN

TA

MO

NIC

A, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

G000 COVER SHEET

D101 1ST & 2ND DEMOLITION FLOOR PLANS

D102 3RD & 4TH DEMOLITION FLOOR PLANS

D200 DEMOLITION ELEVATIONS

A101 PROPOSED 1ST & 2ND FLOOR PLANS

A102 PROPOSED 3RD & 4TH FLOOR PLANS

A200 PROPOSED ELEVATIONS

A800 WINDOW SCHEDULE AND DETAILS

3-31-193-31-19

08.03.18

Page 2: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

(E) WINDOW OR COMPONENT TO BEREMOVED

(E) WALL TO REMAIN

LEGEND

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

6/20

/18

11:0

6:28

AM

D101

1ST & 2NDDEMOLITION FLOOR

PLANS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659

OC

EA

N F

RO

NT

WA

LKS

AN

TA

MO

NIC

A, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0" 1DEMO 1ST FLOOR PLAN

1/8" = 1'-0" 2DEMO 2ND FLOOR PLAN

3-31-19

06.28.1808.03.18

Page 3: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

(E) WINDOW OR COMPONENT TO BEREMOVED

(E) WALL TO REMAIN

LEGEND

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

6/20

/18

11:0

6:42

AM

D102

3RD & 4THDEMOLITION FLOOR

PLANS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659

OC

EA

N F

RO

NT

WA

LKS

AN

TA

MO

NIC

A, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0" 1DEMO 3RD FLOOR PLAN

1/8" = 1'-0" 2DEMO 4TH FLOOR PLAN

3-31-19

06.28.1808.03.18

Page 4: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

4th FLOOR

3rd FLOOR

ROOF

2nd FLOOR

SIDEWALK

1st FLOOR

4th FLOOR

3rd FLOOR

2nd FLOOR

SIDEWALK

1st FLOOR

13

'-5 5

/8"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

9'-1

0 1

/2"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

9'-1

0 1

/2"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

13

'-5 5

/8"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

N2,TYP

N3, TYP

N1, TYP

N2, TYP

N1, TYP

N3, TYP

N1, TYP

N2, TYP

N1, TYP

N6, TYP

N5, TYP N4, TYP N2, TYP N7, TYP

N1.

N2.

N3.

N4.

N5.

N6.

N7.

NON-HISTORICAL SHUTTERS TO BE REMOVED,TYP.

ALUMINUM HORIZONTAL SLIDINGSASHWINDOWS TO BE REMOVED, TYP.

NON-HISTORIC FLOWER BOX TO BE REMOVED,TYP.

DOWNSPOUT TO REMAIN

MOULDING TO REMAIN

QUION CORNER DETAIL TO REMAIN

ORIGINAL SCALLOPED PARAPET TO REMAIN

NOTES

(E) WINDOW OR COMPONENT TO BEREMOVED

(E) WALL TO REMAIN

LEGEND

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

6/20

/18

11:0

6:32

AM

D200

DEMOLITIONELEVATIONS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659

OC

EA

N F

RO

NT

WA

LKS

AN

TA

MO

NIC

A, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0" 2WEST DEMO ELEVATON

1/8" = 1'-0" 1EAST DEMO ELEVATION

1/8" = 1'-0" 4NORTH DEMO ELEVATION

1/8" = 1'-0" 3SOUTH DEMO ELEVATION

3-31-19

06.28.1808.03.18

Page 5: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

NOT IN SCOPE

WINDOW TYPE

LEGEND

X

A.

B.

SEE SHEETS A200 FOR WINDOW LOCATION

COMPLETENESS.

SEE SHEET A800 FOR WINDOW SCHEDULE AND

WINDOW DETAILS.

SHEET NOTES

F F FFGHHJJLLMMNPPP

C

C

C

C

AA BB CCAAAALZZLLZZYXXX

NOT IN SCOPE

DD

EE

EE

DD

Q K KQQQS

QQKKQRKK

A

A

Q K KQTST

QQTS

TUQQ

TT

QQ

TST

Q

A

D

A

K K VT

WST

NOT IN SCOPE

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

6/2

0/1

8 1

1:0

6:1

1 A

M

A101

PROPOSED 1ST & 2ND

FLOOR PLANS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659 O

CE

AN

FR

ON

T W

ALK

SA

NT

A M

ON

ICA

, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0"1

1ST FLOOR PLAN

1/8" = 1'-0"2

2ND FLOOR PLAN

3-31-19

06.28.1808.03.18

Page 6: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

Q K KQQQS

KKKKQRKK

A

A

Q K KQT

ST

QQT

ST

UQQ

TT

QQ

TST

Q

A

E

A

K K VT

W

ST

NOT IN SCOPE

Q K KQQQS

KKKKQRKK

A

A

Q K KQTST

QQTS

TUQQ

TT

QQ

TST

Q

A

E

A

K K VT

WST

NOT IN SCOPE

NOT IN SCOPE

WINDOW TYPE

LEGEND

X

A.

B.

SEE SHEETS A200 FOR WINDOW LOCATION

COMPLETENESS.

SEE SHEET A800 FOR WINDOW SCHEDULE AND

WINDOW DETAILS.

SHEET NOTES

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

6/2

0/1

8 1

1:0

6:1

5 A

M

A102

PROPOSED 3RD & 4TH

FLOOR PLANS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659 O

CE

AN

FR

ON

T W

ALK

SA

NT

A M

ON

ICA

, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0"1

3RD FLOOR PLAN

1/8" = 1'-0"2

4TH FLOOR PLAN

3-31-19

06.28.1808.03.18

Page 7: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

13

'-5 5

/8"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

9'-1

0 1

/2"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

4th FLOOR

3rd FLOOR

ROOF

2nd FLOOR

SIDEWALK

1st FLOOR

9'-1

0 1

/2"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

13

'-5 5

/8"

9'-1

0 1

/2"

9'-1

0 1

/2"

11

'-11

5/8

"

4th FLOOR

3rd FLOOR

2nd FLOOR

1st FLOOR

ROOF

4th FLOOR

3rd FLOOR

ROOF

2nd FLOOR

SIDEWALK

1st FLOOR

NEW, OPERABLE SINGLE HUNG WINDOWSN1.

NOTES

KK

QQ

U

V

TST

QQ

TST

W

TST

QQ

KK

CC BBAA AA AA

L Z Z L L Z Z

Y X X X

KKQQ

UV

TST

QQ

TST

W

TST

QQ

KK

KKQQ

UV

TST

QQ

TST

W

TST

QQ

KK

UV

N1,TYP

PT-1PT-1 PT-1PT-1

PT-1PT-1

PT-1 PT-1 PT-1

PT-1

PT-1

PT-1

CCCC

AA

AA

AA

B

B

N1, TYP

PT-1 PT-1

PT-1

PT-1

FFFFG

HHJJLL

MM

N

KKQQQQ

TSTKKQQ

KKQ

TSTQR

KK

PPP

KKQQQQ

TSTKKQQ

KKQ

TSTQR

KK

KKQQQQ

TSTKKQQ

KKQ

TSTQR

KK

N1, TYP

PT-1 PT-1PT-1PT-1

PT-1 PT-1PT-1PT-1

PT-1

PT-1 PT-1PT-1

PT-1

AAD

AA E

AA E

N1, TYP

PT-1

DDEEEEDD

PT-1

PT-1

PT-1

A.

B.

C.

SEE SHEETS A200 FOR WINDOW LOCATION

COMPLETENESS.

SEE SHEET A800 FOR WINDOW SCHEDULE AND

WINDOW DETAILS.

ENTIRE FACADE INCLUDING QUIOINING,

WINDOW TRIM, DOWNSPOUTS AND RAILINGS TO

BE PAINTED PT-1 UNO.

SHEET NOTES

WINDOW TYPE

PAINT WEDDING VEIL #2125-70 BY

BENJAMIN MOORE OR APPROVED EQUAL

LEGEND

X

PT-1

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

1/8" = 1'-0"

8/3

/18 1

1:1

1:0

8 A

M

A200

PROPOSED

ELEVATIONS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659 O

CE

AN

FR

ON

T W

ALK

SA

NT

A M

ON

ICA

, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

1/8" = 1'-0"4

PROPOSED NORTH ELEVATION

1/8" = 1'-0"1

PROPOSED EAST ELEVATION 1/8" = 1'-0"

3PROPOSED SOUTH ELEVATION

1/8" = 1'-0"2

PROPOSED WEST ELEVATION

3-31-19

08.03.18

Page 8: AD FD FMC OCEAN FRONT WALK · adj aff alt alum approx arch bd bf blk bm btwn cab cl clg clr cmu col conc cont contr cpt crs ct das dbl dia dim dn ds dwg ... 1/8" = 1'-0" 2 demo 4th

ABC

VIF

+/- 4' - 9"

VIF

+/-

4' -

10"

DE

VIF

+/- 2' - 10"

VIF

+/-

1' -

5"

FGHJ

VIF

+/- 3' - 8"

VIF

+/-

5' -

0"

VIF

+/- 3' - 4"

VIF

+/-

4' -

4"

K

VIF

+/- 3' - 4"

VIF

+/-

4' -

10"

L

VIF

+/- 2' - 6"

VIF

+/-

3' -

7"

VIF

+/- 2' - 2"

VIF

+/-

3' -

4"

VIF

+/- 3' - 4"

VIF

+/-

3' -

7" VIF

+/- 2' - 8"

VIF

+/-

2' -

2"

VIF

+/- 2' - 2"

VIF

+/-

4' -

10"

P

VIF

+/- 4' - 9"

VIF

+/-

5' -

6"

Q

VIF

+/- 2' - 10"

VIF

+/-

3' -

6"

R

VIF

+/- 2' - 8"

VIF

+/-

3' -

4"

S

VIF

+/- 4' - 7"

VIF

+/-

4' -

10"

T

VIF

+/- 1' - 6"

VIF

+/-

4' -

10"

U

VIF

+/- 2' - 6"

VIF

+/-

3' -

6"

V

VIF

+/- 4' - 9"

VIF

+/-

5' -

0"

W

VIF

+/- 1' - 6"

VIF

+/-

3' -

6"

X

VIF

+/- 3' - 0"

5' -

6"

Y

VIF

+/- 2' - 6"

VIF

+/-

5' -

10"

Z

VIF

+/- 3' - 0"

VIF

+/-

3' -

7"

VIF

+/- 2' - 10"

VIF

+/-

2' -

0"

AA

VIF

+/- 2' - 2"

VIF

+/-

2' -

0"

VIF

+/- 2' - 10"

VIF

+/-

3' -

2"

BB

VIF

+/- 2' - 2"

VIF

+/-

3' -

2"

CC

M

VIF

+/- 2' - 6"

VIF

+/-

5' -

5"

N

VIF

+/- 1' - 10"

VIF

+/-

3' -

7"

VIF

+/- 8' - 0"

VIF

+/-

5' -

0"

DD

VIF

+/- 2' - 0"

VIF

+/-

7' -

0"

EE

STEP 1. ATTACH SILL STRIPALIGNED WITH OPENING &EXTEND OUT BEYOND OPENING

STEP 3. PLACE WINDOW INTOOPENING W/ NAIL FIN. OVER SILL &JAMB STRIPS. SEAL W/COMPATIBLE SEALANT. INSTALLHEAD STRIP OVER NAIL ON FIN.

STEP 2. ATTACH JAMB STRIPS EVEN WITHOPENING SIDES & ABOVE HEAD & BELOWSTRIP

STEP 4. INSTALL MOISTURE BARRIERBEGINNING AT THE BOTTOM W/ LAYER 1 SOIT LAYS BENEATH THE SILL STRIP.CONTINUE W/ THE ADDITIONALOVERLAPPING LAYERS UP THE WALL OVERTHE JAMB & HEAD STRIPS

1

2

3

SEE PLAN FORWALL TYPE

(E) 5/8" GYP. BD.

(E) BEAM/HEADER

DRYWALLCORNER BEAD,TYP.

(E) STRUCT. SHEATHING

(E) 5/8" EXT. GYP.SHEATHING, WHEREOCCURS

(E) EXT. PLASTER ONLATH OVER MOISTUREBARRIER

SELF ADHEREDWINDOWFLASHING

FBGL NAIL-ONFRAME

CONT. SEALANT

A8006

4A800

5/8" GYP. BD.

EXT. PLASTER ONLATH OVERMOISTURE BARRIER

PLASTERDRIP EDGE

EXTERIOR INTERIOR

NOTE: FOR EXACT PROFILE DIMENSIONS, REFER TO DETAIL 6/A800

6" VIF

FBGL NAIL-ON FRAME

SELF ADHEREDWINDOWFLASHING

(E) 5/8" EXT GYPSHEATHING

(E) EXT PLASTER ONLATH OVERMOISTURE BARRIER

(E) STRUCT SHEATHING

PAINTED MDFSILL

(E) 5/8"GYP. BD.

SEE PLAN FORWALL TYPES

CONT.SEALANT

PTD 1 1/2" MDFTRIM

A8005

+/- 1x4 FIBER CEMENTTRIM TO MATCHORIGINAL HISTORICPROFILE - SEAL ALLFASTENERS

4A800

WOOD BLOCKING

5/8" GYP. BD.

5/8" EXT GYPSHEATHING

EXTERIOR

INTERIOR

NOTE: FOR EXACT PROFILE DIMENSIONS, REFER TO DETAIL 5/A800

6" VIF

WINDOW FLASHINGMEMBRANE LAPPEDOVER WINDOW FLANGE

BED OF SEALANT

SHEATHING SUBSTRATEOR FRAMING

GENERIC FBGLWINDOW FRAME

WINDOW FLANGE

CONT. SEAL ALLATTACHMENTS

MOISTURE BARRIERLAPPED OVER FLASHING

REFER TO DETAIL3/A800 FORCOMPLETE EXTENTSOF EXTERIOR WALL BED OF SEALANT

SHEATHING SUBSTRATEOR FRAMING

GENERIC FBGLWINDOW FRAME

WINDOW FLANGE

CONT. SEAL ALLATTACHMENTS

WINDOW FLASHINGMEMBRANE LAPPED OVERMOISTURE BARRIER

REFER TO DETAIL2/A800 FOR COMPLETEEXTENTS OF EXTERIORWALL

WINDOW ABBREVIATIONSFBGLF/FTEMP

FIBERGLASSFACTORY FINISH - WHITE TEMPERED GLASS

FINISH INTENT OF SINGLE-HUNG WINDOW :MILGRAD SINGLE-HUNG SERIES 3210 ORAPPROVED EQUAL

TH

IS D

RA

WIN

G A

ND

TH

E IN

FO

RM

AT

ION

CO

NT

AIN

ED

HE

RE

IN A

RE

TH

E C

OP

YR

IGH

TE

D W

OR

K O

F O

MG

IVN

ING

AR

CH

ITE

CT

S A

ND

MA

Y N

OT

BE

RE

PR

OD

UC

ED

WIT

HO

UT

WR

ITT

EN

PE

RM

ISS

ION

.

DATE:

SCALE:

SHEET TITLE:

SHEET NUMBER:

JOB NO.:

REVISIONS:

As indicated

7/18

/18

11:1

7:53

AM

A800

WINDOW SCHEDULEAND DETAILS

OC

EA

N F

RO

NT

WA

LK

06.20.18

1659

OC

EA

N F

RO

NT

WA

LKS

AN

TA

MO

NIC

A, C

A 9

0401

WINDOW REPLACEMENT

WILSHIRE SKYLINE

LOS ANGELES, CA 90028

1775 N. ORANGE DR, SUITE 100

18-001

WINDOW SCHEDULE

WINDOWMARK OPERATION

OPENING SIZE

MATERIAL FINISH GLAZING

DETAIL REFERENCES

GUARDRAIL COMMENTSWIDTH HEIGHT HEAD JAMB SILL

A SINGLE HUNG 4' - 9" 4' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS AT 27" IN LIEU OF 42". OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

AA SINGLE HUNG 2' - 2" 2' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

B SINGLE HUNG 3' - 8" 5' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

BB SINGLE HUNG 2' - 10" 3' - 2" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

C SINGLE HUNG 2' - 10" 1' - 5" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

CC SINGLE HUNG 2' - 2" 3' - 2" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

D SINGLE HUNG 2' - 2" 3' - 4" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

DD SINGLE HUNG 8' - 0" 5' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

E SINGLE HUNG 2' - 2" 4' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS AT 27" IN LIEU OF 42". OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

EE SINGLE HUNG 2' - 0" 7' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

F SINGLE HUNG 2' - 10" 2' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

G SINGLE HUNG 2' - 8" 2' - 2" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

H SINGLE HUNG 3' - 4" 4' - 4" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILL EXCEEDS MAXIMUM 44" FOR EMERGENCY EGRESS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

J SINGLE HUNG 3' - 4" 3' - 7" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

K SINGLE HUNG 3' - 4" 4' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS AT 27" IN LIEU OF 42". OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

L SINGLE HUNG 2' - 6" 3' - 7" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

M SINGLE HUNG 2' - 6" 5' - 5" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

N SINGLE HUNG 1' - 10" 3' - 7" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

P SINGLE HUNG 4' - 9" 5' - 6" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

Q SINGLE HUNG 2' - 10" 3' - 6" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

R SINGLE HUNG 2' - 8" 3' - 4" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

S SINGLE HUNG 4' - 7" 4' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS AT 27" IN LIEU OF 42". OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

T SINGLE HUNG 1' - 6" 4' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS AT 27" IN LIEU OF 42". OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

U SINGLE HUNG 2' - 6" 3' - 6" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

V SINGLE HUNG 4' - 9" 5' - 0" FBGL F/F TEMP 3/A800 3/A800 2/A800 No EXISTING NON-COMPLIANT WINDOW SILLS. OWNER TO OBTAIN MODIFICATION TO ALLOW FOR THEIR NON-COMPLIANT USE TO BE GRANDFATHERED.

W SINGLE HUNG 1' - 6" 3' - 6" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

X SINGLE HUNG 3' - 0" 5' - 6" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

Y SINGLE HUNG 2' - 6" 5' - 10" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

Z SINGLE HUNG 3' - 0" 3' - 7" FBGL F/F TEMP 3/A800 3/A800 2/A800 No

3" = 1'-0" 4

WINDOW INSTALLATION & FLASHINGPROCEDURE

3" = 1'-0" 3

WINDOW HEAD (JAMB SIM) @ PLASTER -DETAIL

3" = 1'-0" 2WINDOW SILL @ PLASTER - DETAIL

12" = 1'-0" 6

WINDOW FLASHING HEAD - NAIL-ON FRAME -DETAIL

12" = 1'-0" 5

WINDOW FLASHING SILL - NAIL-ON FRAME -DETAIL

WINDOW SCHEDULE & LEGEND1

3-31-19

08.03.18