Units for mobile telecommunication
applications, split versions, indoor & outdoor
packaged units, range from 1,5 20 kW, withFree Cooling and the new FULL INVERTER DC
Brushless versions in R410a.
TELECOMRANGE
1-16 broch telecom eng 6-02-2013 10:36 Pagina 1
-
8/11/2019 TELECOM RANGE_ENG.pdf
2/16
15' 45' 15' 45'0 30' 30'1h 2h
20
30
40
50
60
70
Black-Out - Power Loss
C
95% 60%
CLIMAVENETA
TELECOMRANGE
2 l 3 TELECOMRANGE
OPERATING RELIABILITY AND CONTINUITY
Constructional rationality plus the proven high quality of
the components ensure that Climavenetas units offer:
- Continuous operation
(24 hours a day, 365 days a year)
- Design life of over 10 years.
- MTBF and MTTR values at the top of their category.
HIGH SENSIBLE COOLING CAPACITYNo latent cooling required.
Since the technological rooms are unmanned, the
latent heat values remain almost zero. Thus, the
requested S.H.R. values (Sensible and Total Cooling
Capacity Ratio) are 95%, compared to typical S.H.R
values around 60% in the manned premises.
BLACK-OUT MANAGEMENTUPS connections system (24/48V DC)
For the double power supply versions (UPS, 48V DC),
instant activation of the FreeCooling function in theevent of a blackout.
Unmanned premises with almost
nil latent heat value.
Required S.H.R. 95%
Manned premises with latent
heat value.
Required S.H.R. 60%
Shelter Inside Temperature
System On
Without Free Cooling
With Free Cooling
Time
1-16 broch telecom eng 6-02-2013 10:36 Pagina 2
-
8/11/2019 TELECOM RANGE_ENG.pdf
3/16
60
50
40
30
20
10
0
-50 Hz 100 200 500
frequency
1K 2K 5K 10K 20K(L) (A)
decibeldB
decibeldB
25
30
40
50
60
70
80
6 kW 15 kW9 kW 6 kW 15 kW9 kW 6 kW 15 kW9 kW
HED + HC ATMED
MID
MICROPROCESSOR CONTROLStand-By and Alarm management
The microprocessor allows:
- easy use by the operator
- management of the unit in stand-by
- automatic rotation on a time basis
- alarm rotation
- alarm management and transmission
- LAN management between connected units
- connection to supervisor systems (SMS)
- double power supply management
- multi-language management
- test function management
MINIMUM SOUND EMISSION
The sound emission reduction of air conditioning units
is one of the greatest needs of telephone units in urban
areas.
Climaveneta has therefore made a new range of high-
efficiency air conditioners featured by a strong sound
emission reduction:
Sound proofing delivery plenum
Antivibrating feet
Compressor inside a sound proofing boxwith lead
Sound proofing recirculating fans cap
Fan speed condenser regulator
Autotransformer to reduce vibration
Measurement on outside with evaporating fan only in Free Cooling.
Measurement on outside during recirculation.
Others/Competitors
Climaveneta
1-16 broch telecom eng 6-02-2013 10:36 Pagina 3
-
8/11/2019 TELECOM RANGE_ENG.pdf
4/16
CLIMAVENETA
TELECOMRANGE
TELEPHONE EXCHANGES, SHELTERS, CABINETS:THE MODERN APPLICATIONS ARECHARACTERIZED BY SPECIFIC NEEDS, WHICH
REQUIRE THE MOST SUITABLE ANDTECHNOLOGICALLY ADVANCED SOLUTIONS.
The constant attention to the market in order to closely monitor and
anticipate the needs and tendencies of the consumer has lead to the
creation of Telecom Range.
This new range of high-efficiency solutions, such as split air
conditioners, indoor and outdoor packaged units are available in Free
Cooling versions with capacities from 1,5 to 20 kW.
4 l 5 TELECOMRANGE
1-16 broch telecom eng 6-02-2013 10:36 Pagina 4
-
8/11/2019 TELECOM RANGE_ENG.pdf
5/16
MED 0010091 pg. 12Packaged Air Conditioners Cooling capacity from 1,5 to 20 kW
FREE COOLING
LED 0010E0015E pg. 14Packaged Air Conditioners Cooling capacity from 2,5 to 5,7 kW
FREE COOLING
HED-HCAT 00110061 pg. 8Split-Air Conditioners Cooling capacity from 4,9 to 15,7 kW
FREE COOLING
MID 0010061 pg. 10Packaged Air Conditioners Cooling capacity from 1,5 to 14,8 kW
FREE COOLING
The latest range of products combines Climavenetas
experience in research and development, with the
quality and reliability of its products.
This strictly depends on the constant improvement of
the technology. Climaveneta has also an extensive sales
network and a series of high standard after sales
services which include: in-house technicians to provide
back-up for the distribution network, training for
external technicians, informative multimedia material,
quality support for sales outlets and a user information
service to guarantee quality.
End-of-line testing on all units
Dedicated project team for telephony products R&D and up of 200 technicians
Customized solutions to customer specifications
Accreditation service for direct orders
Certification of unit specifications in the 8Climaveneta in-house climatic test chambers
Training and technological testing on site
1-16 broch telecom eng 6-02-2013 10:37 Pagina 5
-
8/11/2019 TELECOM RANGE_ENG.pdf
6/16
CLIMAVENETA
TELECOMRANGE
Low operational costs and Low
maintenance costs
Free Cooling with the maximum level of
energy saving
Sound emission reduction thanks to low
noise versions
Continuous operation
(24 hours a day, 365 days a year)
Very high sensible cooling
Precision control and reliability
Microprocessor control (stand-by and alarm
management)
Back-up system and UPS system (24/48 VDC)
Design life of over 10 years
CLIMAVENETA TELECOM RANGE IS THE RESULT OF A RESEARCH ANDDEVELOPMENT PROJECT AMONG DIFFERENT TELECOMMUNICATIONCOMPANIES IN ORDER TO OFFER A NO-COMPROMISE SOLUTION.
6 l 7 TELECOMRANGE
1-16 broch telecom eng 6-02-2013 10:37 Pagina 6
-
8/11/2019 TELECOM RANGE_ENG.pdf
7/16
Constant speed
In case of low Hz Operation
AC Inverter DC Inverter
100%
55%
30%
M
ax70%
M
ax70%
INVERTER TECHNOLOGY
The inverter driven compressor, through variable frequency,
modulates the power capacity provided, optimizing the
performances at part load and increasing efficiency.
A larger capacity can be reached at full load, thus ensuring
that the required temperature will be reached in a shorter
time. Afterwards temperature variations can be easily
controlled with minimized energy consumption becauseonce the set is reached, the compressor works at part load,
reducing energy consumption and effectively maintaining the
desired conditions.
In this respect the new Climaveneta TLC range represents
the ultimate solution in air conditioning for the MOBILE
TELEPHONY, thanks to the most updated compressors DC
Inverter Brushless in all the units.
These units make use of electronic thermostatic valves and
the new generation of EC fans.
Both solutions allow to perfectly adapt the units
performance to the real requirements of the building even at
part load, which represent more than 75% of the operatingtime of the system. This ensures an energy saving up to
50% higher than solutions based on traditional ON/OFF
compressors.
LOW OPERATIONAL COSTS AND
MAINTENANCE COSTS
Choosing the correct, long lasting air conditioning systems
for TLC applications should combine low initial investment
and low operational and maintenance costs.
For this reason the modern FULL INVERTER units deliver
the best costs and benefits ratios, highlighting the meaning
of the TCO (Total Cost of Ownership).
As a consequence, payback time is 2 years compared to
NON FULL INVERTER solutions where payback per unit of
about 3000 units comes only after 10 years.
50% SAVING:
FREE COOLING + INVERTER
It is well known that energy savings are guaranteed with
FREE COOLING systems. Modern FULL INVERTER units
with FREECOOLING combine the technology of modulation
cooling resulting in a 35% energy saving.
Annual Energy Consumption
1-16 broch telecom eng 6-02-2013 10:37 Pagina 7
-
8/11/2019 TELECOM RANGE_ENG.pdf
8/16
8 l 9 TELECOMRANGE
SPLIT AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING
TELECOMRANGE
HED-HCAT00110061
UNIT DESCRIPTIONThe split air conditioners for telecommunication shelters
offer cooling capacity from 4,9 to 15,7 kW.
They are direct expansion systems consisting of motor-operated condensers HCAT 00110061 combined with
indoor units HED 00110061 FC.
Suitable for horizontal installation, they are fitted with
external panels in electrogalvanized steel sheet painted by
cataphoretic process.
The units can be fitted with a Free Cooling damper, which
offers 30% energy savings compared to standard systems.
The evaporating section fan works on a direct current at 48
Volt to ensure operation in an emergency.
Climaveneta units are also made to ensure a standard level
of operation even under extreme environmental conditions
with temperatures up to +48C.
SPLIT
Free Cooling Mechanical
FEATURES Structure and paneling in galvanized cataphoretic coated steel for
maximum resistance to rust.
The reliability and functionality of the compressor and all othercomponents are guaranteed by leading companies in the telecoms sector.
External air intake for Free Cooling units with opening from 0 to 100%(optional).
Contacts for alarms and working state signal plots.
Universal terminal board for outside complete control of the PLC unity.
Adjustable fan speed (optional).
Condensing control for lower noise levels.
Safety pressure switches.
Condensing coil protection grills.
Availability of all accessories required for easy and correct installation,and for a complete and efficient air treatment system.
Electric heating (optional).
Remote terminal per standard provide, on board version (optional).
Serial cards for BMS interconnection (optional).
Humidity sensor (optional).
Condensate draining pump (optional).
1-16 broch telecom eng 6-02-2013 10:37 Pagina 8
-
8/11/2019 TELECOM RANGE_ENG.pdf
9/16
0011 0021 0031 0041 0051 0056 0061
230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50
4,94 6,36 8,43 9,71 10,63 14,28 15,77
4,94 5,65 6,77 9,17 9,53 12,47 13,76
1,18 1,62 2,27 2,37 2,72 3,64 4,1
1450 1450 1600 2450 2450 3200 3200
1450 1450 1600 2450 2450 3200 3200
0,24 0,24 0,29 0,32 0,32 0,48 0,48
0,2 0,2 0,24 0,32 0,32 0,48 0,48
2500 2500 2500 4000 4000 4900 4900
0,16 0,16 0,16 0,14 0,14 0,32 0,32
+48 +48 +48 +48 +48 +48 +48
-25 -25 -25 -25 -25 -25 -25
52 53 56 56 56 58 58
Indoor=27- 45%UR Outdoor=35C
Note
* Available in double configuration 230/1/50 or 400/3N/50
ON/OFF VERSION
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)
Design conditions
0031 0051 0061
230/1/50 230/1/50 400/3N/50
Min Max Min Max Min Max
4,34 9,73 4,84 12,61 6,97 17,3
4,34 7,29 4,84 11,02 6,97 15,64
0,75 2,38 0,78 3,18 1,1 4,23
1450 1450 1600 1600 2000 3900
1450 1450 1600 1600 2000 3900
0,15 0,29 0,18 0,36 0,26 0,52
0,12 0,24 0,16 0,32 0,2 0,4
2500 2500 2500 2500 8640 8640
0,16 0,16 0,32 0,32 0,45 0,45
+48 +48 +48 +48 +48 +48
-25 -25 -25 -25 -25 -25
56 56 58Indoor=27- 45%UR Outdoor=35C Indoor=27- 45%UR Outdoor=35C Indoor=27- 45%UR Outdoor=35C
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)Design conditions
HED HCAT
HED HCAT
0011 0021 0031 0041 0051 0056 0061
930 930 930 1050 1050 1050 1050
311 311 311 406 406 406 406
1500 1500 1500 1524 1524 1524 1524
0011 0021 0031 0041 0051 0056 0061
900 900 900 900 900 900 900
370 370 370 370 370 370 370
740 740 740 990 990 1240 1240
HED
Width mm
Depth mm
Height mm
HCAT
Width mm
Depth mm
Height mm
DIMENSIONS
DIMENSIONS
0031 0051 0061
930 930 930 930 1350 1350
311 311 406 406 406 406
1500 1500 1500 1500 1524 1524
0031 0051 0061
900 900 900 900 1700 1700
420 420 420 420 570 570
1290 1290 1290 1290 1470 1470
HED
Width mm
Depth mm
Height mm
HCAT
Width mm
Depth mm
Height mm
INVERTER VERSION
1-16 broch telecom eng 6-02-2013 10:37 Pagina 9
-
8/11/2019 TELECOM RANGE_ENG.pdf
10/16
10 l 11 TELECOMRANGE
PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING
UNIT DESCRIPTIONThe packaged air conditioners for telecommunication shelters
offer cooling capacity from 1,5 to 14,8 kW. They are directexpansion packaged systems for indoor installation, which
are fitted with external panels in electrogalvanized steel sheet
painted by cataphoretic process.
The units can be fitted with a Free Cooling damper (optional),
which offers 30% energy savings compared to standard
systems. The evaporating section fan (optional) works on a
direct current at 48 Volt to ensure operation in an emergency.
Climaveneta units are also made to ensure a standard level of
operation even under extreme environmental conditions with
temperatures up to +48C.
Available in super silent version.
INDOOR
FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum
resistance to rust (upon request available in peraluman panels).
The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.
External air intake for Free Cooling units with opening from 0 to 100% (optional).
Universal terminal board for outside and complete control of the PLC unity.
Contacts for alarms and working state signal plots.
Double filter (a pre-filter for external air and one for internal one).
Adjustable fan speed(optional).
Condensing control for lower noise levels.
Safety pressure switches.
Differential air pressure switch for dirty filters or faulty fans.
Available with 48 VD/C fans.
Availability of all accessories required for easy and correct installation, for acomplete and efficient air treatment system.
Customer Assistance.
Electric heating (optional).
On board terminal as standard provide, remote terminal version (optional).
Serial cards for BMS interconnection (optional). Humidity sensor (optional).
Condensate draining pump (optional).
Free Cooling Mechanical Free Cooling Mechanical
TELECOMRANGE
MID 0010061
Upflow Dowflow
1-16 broch telecom eng 6-02-2013 10:37 Pagina 10
-
8/11/2019 TELECOM RANGE_ENG.pdf
11/16
001 003 004 0011 0021 0031 0041 0051 0056 0061
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50
1,95 2,91 3,45 4,94 6,09 8,14 9,52 10,64 13,77 14,82
1,42 2,67 2,88 4,94 5,49 6,72 8,64 9,07 12,46 12,93
0,6 0,81 0,98 1,18 1,69 2,33 2,35 2,78 3,51 4,09
300 700 700 1450 1450 1600 2200 2200 3200 3200
300 700 700 1450 1450 1600 2200 2200 3200 3200
0,04 0,115 0,115 0,2 0,2 0,24 0,22 0,22 0,28 0,28
0,04 0,12 0,12 0,2 0,2 0,24 0,32 0,32 0,4 0,4
500 1100 1100 2600 2600 2600 3700 3700 4500 4500
0,12 0,155 0,155 0,42 0,42 0,42 0,45 0,45 0,9 0,9
48 48 48 +48 +48 +48 +48 +48 +48 +48
-25 -25 -25 -25 -25 -25 -25 -25 -25 -25
49 52 52 53 53 54 56 56 60 61
Indoor=27- 45%UR Outdoor=35C
Note
* Available in double configuration 230/1/50 or 400/3N/50
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)
Design conditions
0031 0051 0061
230/1/50 230/1/50 400/3N/50
Min Max Min Max Min Max
4,34 9,53 4,84 12,25 6,58 15,05
4,34 7,09 4,84 10,68 6,26 12,81
0,75 2,37 0,78 3,18 1,1 4,66
800 1600 1600 3200 1600 3200
800 1600 1600 3200 1600 3200
0,14 0,24 0,22 0,4 0,22 0,4
0,12 0,24 0,13 0,26 0,13 0,26
2600 2600 4500 4500 4500 4500
0,42 0,42 0,45 0,45 0,45 0,45
+48 +48 +48 +48 +48 +48
-25 -25 -25 -25 -25 -25
31 51 61
Indoor=27- 45%UR Outdoor=35C
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)
Design conditions
MID
MID
001 003 004 0011 0021 0031 0041 0051 0056 0061
394 505 505 650 650 650 895 895 895 895
250 398 398 650 650 650 750 750 750 750
900 1265 1265 2075 2075 2075 2050 2050 2050 2050
MID
Width mm
Depth mm
Height mm
ON/OFF VERSION
INVERTER VERSION
DIMENSIONS
0031 0051 0061
650 895 895
650 750 750
2075 2050 2050
MID
Width mm
Depth mm
Height mm
DIMENSIONS
1-16 broch telecom eng 6-02-2013 10:37 Pagina 11
-
8/11/2019 TELECOM RANGE_ENG.pdf
12/16
12 l 13 TELECOMRANGE
OUTDOOR
Upflow Dowflow
TELECOMRANGE
MED 0010091
Free Cooling Mechanical Free Cooling Mechanical
PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING
FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum
resistance to rust (on request also available in peraluman panels).
The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.
External air intake for Free Cooling units with opening from 0 to 100%(optional).
Contacts for alarms and working state signal plots.
Universal terminal board for outside complete control of the PLC unity
Adjustable fan speed(optional).
Condensing control for lower noise levels.
Safety pressure switches.
Condensing coil protection grills.
Availability of all accessories required for easy and correct installation, for acomplete and efficient air treatment system.
Customer Assistance.
Electric heating (optional).
On board terminal as standard provide, remote terminal version (optional).
Serial cards for BMS interconnection (optional).
Humidity sensor (optional).
Condensate draining pump (optional).
UNIT DESCRIPTIONThe packaged air conditioners for telecommunication shelters
offer cooling capacity from 1,5 to 20 kW. They are direct
expansion packaged systems for outdoor installation.They are fitted with external paneling in electrogalvanized steel
sheet painted by cataphoretic process. The units can be fitted
with a Free Cooling damper (optional), which offers 30% energy
savings compared to standard systems.
The evaporating section fan works on a direct current at 48 Volt
to ensure operation in an emergency.
Climaveneta units are also made to ensure a standard level of
operation even under extreme environmental conditions with
temperatures up to +48C.
Available in super silent version.
1-16 broch telecom eng 6-02-2013 10:37 Pagina 12
-
8/11/2019 TELECOM RANGE_ENG.pdf
13/16
001 003 004 0011 0021 0031 0041 0051 0056 0061 0071 0091
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50
1,95 2,91 3,45 4,94 6,36 8,43 9,72 10,72 14,26 16,8 18,36 20,57
1,42 2,67 2,88 4,94 5,65 6,77 9,18 9,58 12,54 14,2 14,82 16,56
0,6 0,81 0,98 1,18 1,62 2,27 2,38 2,74 3,41 3,9 4,85 5,61
300 700 700 1450 1450 1600 2450 2450 3200 3500 3500 3900
300 700 700 1450 1450 1600 2450 2450 3200 3500 3500 3900
0,04 0,115 0,115 0,2 0,2 0,24 0,32 0,32 0,4 0,46 0,46 0,52
0,04 0,12 0,12 0,2 0,2 0,24 0,21 0,21 0,26 0,32 0,32 0,32
500 1100 1100 2500 2500 2500 4000 4000 4900 5900 5900 5900
0,12 0,155 0,155 0,16 0,16 0,16 0,29 0,29 0,78 0,45 0,45 0,45
48 48 48 +48 +48 +48 +48 +48 +48 +48 +48 +48
-25 -25 -25 -25 -25 -25 -25 -25 -25 -25 -25 -25
49 52 52 53 53 56 56 56 58 65 65 65
Indoor=27- 45%UR Outdoor=35C
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)
Design conditions
0031 0051 0091
230/1/50 230/1/50 400/3N/50
Min Max Min Max Min Max
4,34 9,53 4,95 12,56 7,96 17,6
4,34 7,22 4,95 10,97 7,96 15,45
0,75 2,37 0,78 3,18 1,18 4,49
1600 1600 3200 3200 3900 3900
1600 1600 3200 3200 3900 3900
0,24 0,24 0,4 0,4 0,52 0,52
0,12 0,24 0,13 0,26 0,2 0,4
2500 2500 4000 4000 5900 5900
0,16 0,16 0,29 0,29 0,45 0,45
+48 +48 +48 +48
-25 -25 -25 -25
52 58 62
Indoor=27- 45%UR Outdoor=35C
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor power input kW
Evaporator air flow m3/h
Freecooling air flow m3/h
Evaporator fan AC power input kW
Evaporator fan DC power input kW
Condenser max air flow m3/h
Condenser fan AC power input kW
Max ambient temperature C
Min ambient temperature C
Outdoor sound pressure level at 1mt dB(A)
Design conditions
MED
MED
001 003 004 0011 0021 0031 0041 0051 0056 0061 0071 0091
394 505 505 960 960 960 990 990 990 1120 1120 1120
250 398 398 500 500 500 600 600 600 780 780 780
900 1265 1265 1700 1700 1700 2100 2100 2100 2240 2240 2240
MED
Width mm
Depth mm
Height mm
Note
* Available in double configuration 230/1/50 or 400/3N/50
ON/OFF VERSION
DIMENSIONS
0031 0051 0091
960 990 1120
500 600 780
1700 2100 2240
MED
Width mm
Depth mm
Height mm
DIMENSIONS
INVERTER VERSION
1-16 broch telecom eng 6-02-2013 10:37 Pagina 13
-
8/11/2019 TELECOM RANGE_ENG.pdf
14/16
Mechanical Free Cooling
14 l 15 TELECOMRANGE
PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION CABINETFREE COOLING
OUTDOOR/INDOOR
FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum
resistance to rust (on request also available in peraluman panels).
The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.
External air intake for the Free Cooling with opening from 0 to 100%(optional).
Available both in electro-mechanic version and electronic version.
Contacts for alarms and working state signal plots.
Universal terminal board for outside complete control of the PLC unity
Double filter (a pre-filter for external air and one for internal one).
Adjustable fan speed (optional).
Condensing control for lower noise levels.
Safety pressure switches.
Condensing coil protection grills.
Availability of all accessories required for easy and correct installation, and fora complete and efficient air treatment system.
Available both electromechanical version and electronic version.
Customer Assistance.
Electric heating (optional).
On board terminal per standard provide, remote terminal version (optional).
Serial cards for BMS interconnection (optional).
Humidity sensor (optional).
Condensate draining pump (optional).
UNIT DESCRIPTIONPackaged air conditioners for telecommunication CABINETS
come in from the 2.5 kW to the 5,5 kW size.
They are direct expansion packaged systems for outdoor
installation. They are fitted with external panels inelectrogalvanized steel sheet painted with cataphoretic
process or in peraluman panels on request.
The units can be fitted with a Free Cooling damper, which
offers 30% energy savings compared to standard systems.
The evaporating section fan works on direct current at 48V to
ensure operation in an emergency.
Climaveneta units are also made to ensure a standard level of
operation even under extreme environmental conditions with
temperatures up to +46C.
TELECOMRANGE
LED 0010E0015E
1-16 broch telecom eng 6-02-2013 10:37 Pagina 14
-
8/11/2019 TELECOM RANGE_ENG.pdf
15/16
0010-0010E 0015-0015E
220/1/50
2,5 5,7
2,2 5,2
0,84 1,6
0,10 0,40
0,18 0,9
0,1 0,14
470 1500
500 1600
750 2000
50 53
36 39
46 46
1 1,5
Power supply V/Ph/Hz
Total cooling capacity kW
Sensible cooling capacity kW
Compressor AC power input kW
Condenser AC power input kW
Evaporator AC power input kW
Evaporator fan DC power input (48VDC) kW
Freecooling air flow m3/h
Evaporator air flow m3/h
Condenser max air flow m3/h
Outdoor sound pressure level at 1mt dB(A)
Outdoor sound pressure level at 5mt dB(A)
Max ambient temperature C
Electric heating kW
LED
0010 0010E 0015-0015E
600 750 1000
600 750 800
353 353 410
LED
Width mm
Depth mm
Height mm
DIMENSIONS