    Units for mobile telecommunication

    applications, split versions, indoor & outdoor

    packaged units, range from 1,5 20 kW, withFree Cooling and the new FULL INVERTER DC

    Brushless versions in R410a.

    TELECOMRANGE

    1-16 broch telecom eng 6-02-2013 10:36 Pagina 1

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    2/16

    15' 45' 15' 45'0 30' 30'1h 2h

    20

    30

    40

    50

    60

    70

    Black-Out - Power Loss

    C

    95% 60%

    CLIMAVENETA

    TELECOMRANGE

    2 l 3 TELECOMRANGE

    OPERATING RELIABILITY AND CONTINUITY

    Constructional rationality plus the proven high quality of

    the components ensure that Climavenetas units offer:

    - Continuous operation

    (24 hours a day, 365 days a year)

    - Design life of over 10 years.

    - MTBF and MTTR values at the top of their category.

    HIGH SENSIBLE COOLING CAPACITYNo latent cooling required.

    Since the technological rooms are unmanned, the

    latent heat values remain almost zero. Thus, the

    requested S.H.R. values (Sensible and Total Cooling

    Capacity Ratio) are 95%, compared to typical S.H.R

    values around 60% in the manned premises.

    BLACK-OUT MANAGEMENTUPS connections system (24/48V DC)

    For the double power supply versions (UPS, 48V DC),

    instant activation of the FreeCooling function in theevent of a blackout.

    Unmanned premises with almost

    nil latent heat value.

    Required S.H.R. 95%

    Manned premises with latent

    heat value.

    Required S.H.R. 60%

    Shelter Inside Temperature

    System On

    Without Free Cooling

    With Free Cooling

    Time

    1-16 broch telecom eng 6-02-2013 10:36 Pagina 2

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    3/16

    60

    50

    40

    30

    20

    10

    0

    -50 Hz 100 200 500

    frequency

    1K 2K 5K 10K 20K(L) (A)

    decibeldB

    decibeldB

    25

    30

    40

    50

    60

    70

    80

    6 kW 15 kW9 kW 6 kW 15 kW9 kW 6 kW 15 kW9 kW

    HED + HC ATMED

    MID

    MICROPROCESSOR CONTROLStand-By and Alarm management

    The microprocessor allows:

    - easy use by the operator

    - management of the unit in stand-by

    - automatic rotation on a time basis

    - alarm rotation

    - alarm management and transmission

    - LAN management between connected units

    - connection to supervisor systems (SMS)

    - double power supply management

    - multi-language management

    - test function management

    MINIMUM SOUND EMISSION

    The sound emission reduction of air conditioning units

    is one of the greatest needs of telephone units in urban

    areas.

    Climaveneta has therefore made a new range of high-

    efficiency air conditioners featured by a strong sound

    emission reduction:

    Sound proofing delivery plenum

    Antivibrating feet

    Compressor inside a sound proofing boxwith lead

    Sound proofing recirculating fans cap

    Fan speed condenser regulator

    Autotransformer to reduce vibration

    Measurement on outside with evaporating fan only in Free Cooling.

    Measurement on outside during recirculation.

    Others/Competitors

    Climaveneta

    1-16 broch telecom eng 6-02-2013 10:36 Pagina 3

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    4/16

    CLIMAVENETA

    TELECOMRANGE

    TELEPHONE EXCHANGES, SHELTERS, CABINETS:THE MODERN APPLICATIONS ARECHARACTERIZED BY SPECIFIC NEEDS, WHICH

    REQUIRE THE MOST SUITABLE ANDTECHNOLOGICALLY ADVANCED SOLUTIONS.

    The constant attention to the market in order to closely monitor and

    anticipate the needs and tendencies of the consumer has lead to the

    creation of Telecom Range.

    This new range of high-efficiency solutions, such as split air

    conditioners, indoor and outdoor packaged units are available in Free

    Cooling versions with capacities from 1,5 to 20 kW.

    4 l 5 TELECOMRANGE

    1-16 broch telecom eng 6-02-2013 10:36 Pagina 4

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    5/16

    MED 0010091 pg. 12Packaged Air Conditioners Cooling capacity from 1,5 to 20 kW

    FREE COOLING

    LED 0010E0015E pg. 14Packaged Air Conditioners Cooling capacity from 2,5 to 5,7 kW

    FREE COOLING

    HED-HCAT 00110061 pg. 8Split-Air Conditioners Cooling capacity from 4,9 to 15,7 kW

    FREE COOLING

    MID 0010061 pg. 10Packaged Air Conditioners Cooling capacity from 1,5 to 14,8 kW

    FREE COOLING

    The latest range of products combines Climavenetas

    experience in research and development, with the

    quality and reliability of its products.

    This strictly depends on the constant improvement of

    the technology. Climaveneta has also an extensive sales

    network and a series of high standard after sales

    services which include: in-house technicians to provide

    back-up for the distribution network, training for

    external technicians, informative multimedia material,

    quality support for sales outlets and a user information

    service to guarantee quality.

    End-of-line testing on all units

    Dedicated project team for telephony products R&D and up of 200 technicians

    Customized solutions to customer specifications

    Accreditation service for direct orders

    Certification of unit specifications in the 8Climaveneta in-house climatic test chambers

    Training and technological testing on site

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 5

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    6/16

    CLIMAVENETA

    TELECOMRANGE

    Low operational costs and Low

    maintenance costs

    Free Cooling with the maximum level of

    energy saving

    Sound emission reduction thanks to low

    noise versions

    Continuous operation

    (24 hours a day, 365 days a year)

    Very high sensible cooling

    Precision control and reliability

    Microprocessor control (stand-by and alarm

    management)

    Back-up system and UPS system (24/48 VDC)

    Design life of over 10 years

    CLIMAVENETA TELECOM RANGE IS THE RESULT OF A RESEARCH ANDDEVELOPMENT PROJECT AMONG DIFFERENT TELECOMMUNICATIONCOMPANIES IN ORDER TO OFFER A NO-COMPROMISE SOLUTION.

    6 l 7 TELECOMRANGE

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 6

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    7/16

    Constant speed

    In case of low Hz Operation

    AC Inverter DC Inverter

    100%

    55%

    30%

    M

    ax70%

    M

    ax70%

    INVERTER TECHNOLOGY

    The inverter driven compressor, through variable frequency,

    modulates the power capacity provided, optimizing the

    performances at part load and increasing efficiency.

    A larger capacity can be reached at full load, thus ensuring

    that the required temperature will be reached in a shorter

    time. Afterwards temperature variations can be easily

    controlled with minimized energy consumption becauseonce the set is reached, the compressor works at part load,

    reducing energy consumption and effectively maintaining the

    desired conditions.

    In this respect the new Climaveneta TLC range represents

    the ultimate solution in air conditioning for the MOBILE

    TELEPHONY, thanks to the most updated compressors DC

    Inverter Brushless in all the units.

    These units make use of electronic thermostatic valves and

    the new generation of EC fans.

    Both solutions allow to perfectly adapt the units

    performance to the real requirements of the building even at

    part load, which represent more than 75% of the operatingtime of the system. This ensures an energy saving up to

    50% higher than solutions based on traditional ON/OFF

    compressors.

    LOW OPERATIONAL COSTS AND

    MAINTENANCE COSTS

    Choosing the correct, long lasting air conditioning systems

    for TLC applications should combine low initial investment

    and low operational and maintenance costs.

    For this reason the modern FULL INVERTER units deliver

    the best costs and benefits ratios, highlighting the meaning

    of the TCO (Total Cost of Ownership).

    As a consequence, payback time is 2 years compared to

    NON FULL INVERTER solutions where payback per unit of

    about 3000 units comes only after 10 years.

    50% SAVING:

    FREE COOLING + INVERTER

    It is well known that energy savings are guaranteed with

    FREE COOLING systems. Modern FULL INVERTER units

    with FREECOOLING combine the technology of modulation

    cooling resulting in a 35% energy saving.

    Annual Energy Consumption

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 7

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    8/16

    8 l 9 TELECOMRANGE

    SPLIT AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING

    TELECOMRANGE

    HED-HCAT00110061

    UNIT DESCRIPTIONThe split air conditioners for telecommunication shelters

    offer cooling capacity from 4,9 to 15,7 kW.

    They are direct expansion systems consisting of motor-operated condensers HCAT 00110061 combined with

    indoor units HED 00110061 FC.

    Suitable for horizontal installation, they are fitted with

    external panels in electrogalvanized steel sheet painted by

    cataphoretic process.

    The units can be fitted with a Free Cooling damper, which

    offers 30% energy savings compared to standard systems.

    The evaporating section fan works on a direct current at 48

    Volt to ensure operation in an emergency.

    Climaveneta units are also made to ensure a standard level

    of operation even under extreme environmental conditions

    with temperatures up to +48C.

    SPLIT

    Free Cooling Mechanical

    FEATURES Structure and paneling in galvanized cataphoretic coated steel for

    maximum resistance to rust.

    The reliability and functionality of the compressor and all othercomponents are guaranteed by leading companies in the telecoms sector.

    External air intake for Free Cooling units with opening from 0 to 100%(optional).

    Contacts for alarms and working state signal plots.

    Universal terminal board for outside complete control of the PLC unity.

    Adjustable fan speed (optional).

    Condensing control for lower noise levels.

    Safety pressure switches.

    Condensing coil protection grills.

    Availability of all accessories required for easy and correct installation,and for a complete and efficient air treatment system.

    Electric heating (optional).

    Remote terminal per standard provide, on board version (optional).

    Serial cards for BMS interconnection (optional).

    Humidity sensor (optional).

    Condensate draining pump (optional).

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 8

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    9/16

    0011 0021 0031 0041 0051 0056 0061

    230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50

    4,94 6,36 8,43 9,71 10,63 14,28 15,77

    4,94 5,65 6,77 9,17 9,53 12,47 13,76

    1,18 1,62 2,27 2,37 2,72 3,64 4,1

    1450 1450 1600 2450 2450 3200 3200

    1450 1450 1600 2450 2450 3200 3200

    0,24 0,24 0,29 0,32 0,32 0,48 0,48

    0,2 0,2 0,24 0,32 0,32 0,48 0,48

    2500 2500 2500 4000 4000 4900 4900

    0,16 0,16 0,16 0,14 0,14 0,32 0,32

    +48 +48 +48 +48 +48 +48 +48

    -25 -25 -25 -25 -25 -25 -25

    52 53 56 56 56 58 58

    Indoor=27- 45%UR Outdoor=35C

    Note

    * Available in double configuration 230/1/50 or 400/3N/50

    ON/OFF VERSION

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)

    Design conditions

    0031 0051 0061

    230/1/50 230/1/50 400/3N/50

    Min Max Min Max Min Max

    4,34 9,73 4,84 12,61 6,97 17,3

    4,34 7,29 4,84 11,02 6,97 15,64

    0,75 2,38 0,78 3,18 1,1 4,23

    1450 1450 1600 1600 2000 3900

    1450 1450 1600 1600 2000 3900

    0,15 0,29 0,18 0,36 0,26 0,52

    0,12 0,24 0,16 0,32 0,2 0,4

    2500 2500 2500 2500 8640 8640

    0,16 0,16 0,32 0,32 0,45 0,45

    +48 +48 +48 +48 +48 +48

    -25 -25 -25 -25 -25 -25

    56 56 58Indoor=27- 45%UR Outdoor=35C Indoor=27- 45%UR Outdoor=35C Indoor=27- 45%UR Outdoor=35C

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)Design conditions

    HED HCAT

    HED HCAT

    0011 0021 0031 0041 0051 0056 0061

    930 930 930 1050 1050 1050 1050

    311 311 311 406 406 406 406

    1500 1500 1500 1524 1524 1524 1524

    0011 0021 0031 0041 0051 0056 0061

    900 900 900 900 900 900 900

    370 370 370 370 370 370 370

    740 740 740 990 990 1240 1240

    HED

    Width mm

    Depth mm

    Height mm

    HCAT

    Width mm

    Depth mm

    Height mm

    DIMENSIONS

    DIMENSIONS

    0031 0051 0061

    930 930 930 930 1350 1350

    311 311 406 406 406 406

    1500 1500 1500 1500 1524 1524

    0031 0051 0061

    900 900 900 900 1700 1700

    420 420 420 420 570 570

    1290 1290 1290 1290 1470 1470

    HED

    Width mm

    Depth mm

    Height mm

    HCAT

    Width mm

    Depth mm

    Height mm

    INVERTER VERSION

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 9

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    10/16

    10 l 11 TELECOMRANGE

    PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING

    UNIT DESCRIPTIONThe packaged air conditioners for telecommunication shelters

    offer cooling capacity from 1,5 to 14,8 kW. They are directexpansion packaged systems for indoor installation, which

    are fitted with external panels in electrogalvanized steel sheet

    painted by cataphoretic process.

    The units can be fitted with a Free Cooling damper (optional),

    which offers 30% energy savings compared to standard

    systems. The evaporating section fan (optional) works on a

    direct current at 48 Volt to ensure operation in an emergency.

    Climaveneta units are also made to ensure a standard level of

    operation even under extreme environmental conditions with

    temperatures up to +48C.

    Available in super silent version.

    INDOOR

    FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum

    resistance to rust (upon request available in peraluman panels).

    The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.

    External air intake for Free Cooling units with opening from 0 to 100% (optional).

    Universal terminal board for outside and complete control of the PLC unity.

    Contacts for alarms and working state signal plots.

    Double filter (a pre-filter for external air and one for internal one).

    Adjustable fan speed(optional).

    Condensing control for lower noise levels.

    Safety pressure switches.

    Differential air pressure switch for dirty filters or faulty fans.

    Available with 48 VD/C fans.

    Availability of all accessories required for easy and correct installation, for acomplete and efficient air treatment system.

    Customer Assistance.

    Electric heating (optional).

    On board terminal as standard provide, remote terminal version (optional).

    Serial cards for BMS interconnection (optional). Humidity sensor (optional).

    Condensate draining pump (optional).

    Free Cooling Mechanical Free Cooling Mechanical

    TELECOMRANGE

    MID 0010061

    Upflow Dowflow

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 10

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    11/16

    001 003 004 0011 0021 0031 0041 0051 0056 0061

    230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50

    1,95 2,91 3,45 4,94 6,09 8,14 9,52 10,64 13,77 14,82

    1,42 2,67 2,88 4,94 5,49 6,72 8,64 9,07 12,46 12,93

    0,6 0,81 0,98 1,18 1,69 2,33 2,35 2,78 3,51 4,09

    300 700 700 1450 1450 1600 2200 2200 3200 3200

    300 700 700 1450 1450 1600 2200 2200 3200 3200

    0,04 0,115 0,115 0,2 0,2 0,24 0,22 0,22 0,28 0,28

    0,04 0,12 0,12 0,2 0,2 0,24 0,32 0,32 0,4 0,4

    500 1100 1100 2600 2600 2600 3700 3700 4500 4500

    0,12 0,155 0,155 0,42 0,42 0,42 0,45 0,45 0,9 0,9

    48 48 48 +48 +48 +48 +48 +48 +48 +48

    -25 -25 -25 -25 -25 -25 -25 -25 -25 -25

    49 52 52 53 53 54 56 56 60 61

    Indoor=27- 45%UR Outdoor=35C

    Note

    * Available in double configuration 230/1/50 or 400/3N/50

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)

    Design conditions

    0031 0051 0061

    230/1/50 230/1/50 400/3N/50

    Min Max Min Max Min Max

    4,34 9,53 4,84 12,25 6,58 15,05

    4,34 7,09 4,84 10,68 6,26 12,81

    0,75 2,37 0,78 3,18 1,1 4,66

    800 1600 1600 3200 1600 3200

    800 1600 1600 3200 1600 3200

    0,14 0,24 0,22 0,4 0,22 0,4

    0,12 0,24 0,13 0,26 0,13 0,26

    2600 2600 4500 4500 4500 4500

    0,42 0,42 0,45 0,45 0,45 0,45

    +48 +48 +48 +48 +48 +48

    -25 -25 -25 -25 -25 -25

    31 51 61

    Indoor=27- 45%UR Outdoor=35C

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)

    Design conditions

    MID

    MID

    001 003 004 0011 0021 0031 0041 0051 0056 0061

    394 505 505 650 650 650 895 895 895 895

    250 398 398 650 650 650 750 750 750 750

    900 1265 1265 2075 2075 2075 2050 2050 2050 2050

    MID

    Width mm

    Depth mm

    Height mm

    ON/OFF VERSION

    INVERTER VERSION

    DIMENSIONS

    0031 0051 0061

    650 895 895

    650 750 750

    2075 2050 2050

    MID

    Width mm

    Depth mm

    Height mm

    DIMENSIONS

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 11

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    12/16

    12 l 13 TELECOMRANGE

    OUTDOOR

    Upflow Dowflow

    TELECOMRANGE

    MED 0010091

    Free Cooling Mechanical Free Cooling Mechanical

    PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION SHELTERSFREE COOLING

    FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum

    resistance to rust (on request also available in peraluman panels).

    The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.

    External air intake for Free Cooling units with opening from 0 to 100%(optional).

    Contacts for alarms and working state signal plots.

    Universal terminal board for outside complete control of the PLC unity

    Adjustable fan speed(optional).

    Condensing control for lower noise levels.

    Safety pressure switches.

    Condensing coil protection grills.

    Availability of all accessories required for easy and correct installation, for acomplete and efficient air treatment system.

    Customer Assistance.

    Electric heating (optional).

    On board terminal as standard provide, remote terminal version (optional).

    Serial cards for BMS interconnection (optional).

    Humidity sensor (optional).

    Condensate draining pump (optional).

    UNIT DESCRIPTIONThe packaged air conditioners for telecommunication shelters

    offer cooling capacity from 1,5 to 20 kW. They are direct

    expansion packaged systems for outdoor installation.They are fitted with external paneling in electrogalvanized steel

    sheet painted by cataphoretic process. The units can be fitted

    with a Free Cooling damper (optional), which offers 30% energy

    savings compared to standard systems.

    The evaporating section fan works on a direct current at 48 Volt

    to ensure operation in an emergency.

    Climaveneta units are also made to ensure a standard level of

    operation even under extreme environmental conditions with

    temperatures up to +48C.

    Available in super silent version.

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 12

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    13/16

    001 003 004 0011 0021 0031 0041 0051 0056 0061 0071 0091

    230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 * 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50

    1,95 2,91 3,45 4,94 6,36 8,43 9,72 10,72 14,26 16,8 18,36 20,57

    1,42 2,67 2,88 4,94 5,65 6,77 9,18 9,58 12,54 14,2 14,82 16,56

    0,6 0,81 0,98 1,18 1,62 2,27 2,38 2,74 3,41 3,9 4,85 5,61

    300 700 700 1450 1450 1600 2450 2450 3200 3500 3500 3900

    300 700 700 1450 1450 1600 2450 2450 3200 3500 3500 3900

    0,04 0,115 0,115 0,2 0,2 0,24 0,32 0,32 0,4 0,46 0,46 0,52

    0,04 0,12 0,12 0,2 0,2 0,24 0,21 0,21 0,26 0,32 0,32 0,32

    500 1100 1100 2500 2500 2500 4000 4000 4900 5900 5900 5900

    0,12 0,155 0,155 0,16 0,16 0,16 0,29 0,29 0,78 0,45 0,45 0,45

    48 48 48 +48 +48 +48 +48 +48 +48 +48 +48 +48

    -25 -25 -25 -25 -25 -25 -25 -25 -25 -25 -25 -25

    49 52 52 53 53 56 56 56 58 65 65 65

    Indoor=27- 45%UR Outdoor=35C

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)

    Design conditions

    0031 0051 0091

    230/1/50 230/1/50 400/3N/50

    Min Max Min Max Min Max

    4,34 9,53 4,95 12,56 7,96 17,6

    4,34 7,22 4,95 10,97 7,96 15,45

    0,75 2,37 0,78 3,18 1,18 4,49

    1600 1600 3200 3200 3900 3900

    1600 1600 3200 3200 3900 3900

    0,24 0,24 0,4 0,4 0,52 0,52

    0,12 0,24 0,13 0,26 0,2 0,4

    2500 2500 4000 4000 5900 5900

    0,16 0,16 0,29 0,29 0,45 0,45

    +48 +48 +48 +48

    -25 -25 -25 -25

    52 58 62

    Indoor=27- 45%UR Outdoor=35C

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor power input kW

    Evaporator air flow m3/h

    Freecooling air flow m3/h

    Evaporator fan AC power input kW

    Evaporator fan DC power input kW

    Condenser max air flow m3/h

    Condenser fan AC power input kW

    Max ambient temperature C

    Min ambient temperature C

    Outdoor sound pressure level at 1mt dB(A)

    Design conditions

    MED

    MED

    001 003 004 0011 0021 0031 0041 0051 0056 0061 0071 0091

    394 505 505 960 960 960 990 990 990 1120 1120 1120

    250 398 398 500 500 500 600 600 600 780 780 780

    900 1265 1265 1700 1700 1700 2100 2100 2100 2240 2240 2240

    MED

    Width mm

    Depth mm

    Height mm

    Note

    * Available in double configuration 230/1/50 or 400/3N/50

    ON/OFF VERSION

    DIMENSIONS

    0031 0051 0091

    960 990 1120

    500 600 780

    1700 2100 2240

    MED

    Width mm

    Depth mm

    Height mm

    DIMENSIONS

    INVERTER VERSION

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 13

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    14/16

    Mechanical Free Cooling

    14 l 15 TELECOMRANGE

    PACKAGED AIR CONDITIONERS FOR TELECOMMUNICATION CABINETFREE COOLING

    OUTDOOR/INDOOR

    FEATURES Structure and paneling in galvanized cataphoretic coated steel for maximum

    resistance to rust (on request also available in peraluman panels).

    The reliability and functionality of the compressor and all other componentsare guaranteed by leading companies in the telecoms sector.

    External air intake for the Free Cooling with opening from 0 to 100%(optional).

    Available both in electro-mechanic version and electronic version.

    Contacts for alarms and working state signal plots.

    Universal terminal board for outside complete control of the PLC unity

    Double filter (a pre-filter for external air and one for internal one).

    Adjustable fan speed (optional).

    Condensing control for lower noise levels.

    Safety pressure switches.

    Condensing coil protection grills.

    Availability of all accessories required for easy and correct installation, and fora complete and efficient air treatment system.

    Available both electromechanical version and electronic version.

    Customer Assistance.

    Electric heating (optional).

    On board terminal per standard provide, remote terminal version (optional).

    Serial cards for BMS interconnection (optional).

    Humidity sensor (optional).

    Condensate draining pump (optional).

    UNIT DESCRIPTIONPackaged air conditioners for telecommunication CABINETS

    come in from the 2.5 kW to the 5,5 kW size.

    They are direct expansion packaged systems for outdoor

    installation. They are fitted with external panels inelectrogalvanized steel sheet painted with cataphoretic

    process or in peraluman panels on request.

    The units can be fitted with a Free Cooling damper, which

    offers 30% energy savings compared to standard systems.

    The evaporating section fan works on direct current at 48V to

    ensure operation in an emergency.

    Climaveneta units are also made to ensure a standard level of

    operation even under extreme environmental conditions with

    temperatures up to +46C.

    TELECOMRANGE

    LED 0010E0015E

    1-16 broch telecom eng 6-02-2013 10:37 Pagina 14

  • 8/11/2019 TELECOM RANGE_ENG.pdf

    15/16

    0010-0010E 0015-0015E

    220/1/50

    2,5 5,7

    2,2 5,2

    0,84 1,6

    0,10 0,40

    0,18 0,9

    0,1 0,14

    470 1500

    500 1600

    750 2000

    50 53

    36 39

    46 46

    1 1,5

    Power supply V/Ph/Hz

    Total cooling capacity kW

    Sensible cooling capacity kW

    Compressor AC power input kW

    Condenser AC power input kW

    Evaporator AC power input kW

    Evaporator fan DC power input (48VDC) kW

    Freecooling air flow m3/h

    Evaporator air flow m3/h

    Condenser max air flow m3/h

    Outdoor sound pressure level at 1mt dB(A)

    Outdoor sound pressure level at 5mt dB(A)

    Max ambient temperature C

    Electric heating kW

    LED

    0010 0010E 0015-0015E

    600 750 1000

    600 750 800

    353 353 410

    LED

    Width mm

    Depth mm

    Height mm

    DIMENSIONS