ReAquant™ Reagent System
Transcript of ReAquant™ Reagent System
ReAquant Reagent
System The ReAquant Reagent System represents a breakthrough in the titri-metric end-point determination of water (moisture) content. It consists of ReAquant Titrant and ReAquant Solvent. Used together, they offer distinct advantages over conventional Karl Fischer methods to analysts involved in the determination of "free" water for pharmaceutical, petro-chemical and industrial chemical quality control.
ReAquant Solvent Is a methanolic solution containing some components of the titration system, and is used for the dissolution and dilution of samples.
ReAquant Titrant Contains methanol and iodine. The approximate titer, as stated on the label, is 3.5 mg of water per milliliter.
Π No Odor Problem J. T. Baker ReAquant reagents are completely free of both pyridine and sulfur dioxide. Hence, no obnoxious or lasting odors are generated.
Π Expanded Range The ReAquant technique, under stringent laboratory testing, has been used successfully to determine the water content of a variety of materials, even troublesome samples such as ketones.
D Excellent Correlation In blind studies under a variety of conditions, the ReAquant system has been found to correlate exceptionally well with results obtained by conventional titration.
Sample A Β C
Water Content, % W/V By KF
Titration 2.43 0.85 2.20
By ReAquant Titration
2.33 0.82 2.27
Π Sharp Endpoint A sharp, non-fleeting endpoint is required for precise moisture titrations. The ReAquant buffered system of t i trant plus solvent fulfills this need both visually and electrometrically. Since sulfur dioxide is absent in ReAquant products, no yellow S 0 2 r complex is formed, facilitating the recognition of the visual endpoint. ReAquant endpoints also hold well once reached, lasting at least 20 seconds.
Π Rapid Reaction Time Quality control analysts in the industrial and pharmaceutical fields will benefit by using ReAquant reagents. The combination of stable t i trant and complementary solvent with built-in buffering capacity affords a rapid titration. This is a desirable feature in multi-sample moisture analysis.
CIRCLE 5 ON READER SERVICE CARD
Π ReAquant Procedure Titration using the ReAquant method requires no special equipment adaptation or complicated procedures. An apparatus or assembly used with conventional Karl Fischer titrations is recommended.
'Baker Analyzed'®ReAquant Titrant and ReAquant Solvent are supplied in 1-liter and 2.5-liter sizes.
J.T.Baker
Our75 ,hYear J. T. Baker Chemical Co. Laboratory Products Phillipsburg, NJ 08865 (201)859-2151
2 C&EN Oct. 1, 1979