IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

72
1 11111 soffst INGENIEURBÜRO FÜR TECHNOLOGIE TRANSFER DIPL.-ING. B. P. SCHULZ-HEISE TTI Trans Tech International © 2021 IBH Link IoT Training IBH Link IoT Manual Version 5.20

Transcript of IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Page 1: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

1 11111 soffst I N G E N I E U R B Ü R O F Ü RTECHNOLOGIE TRANSFERDIPL. -ING. B. P. SCHULZ-HEISE

TTI Trans Tech International© 2021 IBH Link IoT Training

IBH Link IoT

Manual

Version 5.20

Page 2: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link IoT Training TTI Trans Tech International© 2021

IBHsoftec GmbH

Turmstr. 77

64760 Oberzent / Beerfelden

Tel.: +49 6068 3001

Fax: +49 6068 3074

[email protected]

www.ibhsoftec.com

TTI Ingenieurbüro für

Technologie Transfer

Dipl. Ing. B. Peter Schulz-Heise

Tel.: +49 6061 3382

Fax: +49 6061 71162

TTI@ schulz-heise.com

www.schulz-heise.com

Windows® is a registered trademark of Microsoft® Corporation. TeamViewer® is a registered trademark of TeamViewer AG, Göppingen. Simatic® S5, Step® 5, Simatic® S7, Step® 7, S7-200®, S7-300®, S7-400®, S7-1200®; S7-1500® and GRAPH® 5 are registered trademarks of Siemens Aktiengesellschaft, Berlin and Munich. Image source: © Siemens AG 2001, All rights reserved. Product names are trademarks of their respective owners.

Page 3: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Version V5.20 Contents Page I

.....................................................

...........................................

..............................................

..........................................

TTI Trans-Tech International© 2021

................................

............................................................................................

........................................................................

................

IBH Link IoT Training

................................................................

....................................................

................................

................................................

.............................................................

......................................................

Contents

..............................................

....................

Contents

................................

............................................................

................................................................

I

..............................

1 IBH Link IoT setup

..................................................................

..........................................................

................

1-1

.............................................................

............

1.1 Installation and connection

................................................................

.........................................................................

1-1

....................................................

...........................

1.2 Configuration of the IP addresses (default setting)

................................

................................................................................

...........

1-2

................................

....................................

Standard IP-Address configuration:

................................

..................................

...........................................................

......................

1-3

................................

.............................................

1.3 Login browser window

................................

..................................................................................................

...................

1-3

................................................................

...........Language selection ................................................................

..........................................................

..................

1-4

................................

............

...................

Remember me

................................

..........................................................

.....................

1-4

................................................................

Login 1-4

Change Password 1-4

1.4 Network browser window 1-5

1.4.1 Management Level Settings 1-5 1.4.2 Setting the IP address - management level 1-6 1.4.3 Control Level Settings 1-6

Control level with adapted IP addresses 1-7 1.4.4 802.1x settings 1-7 1.4.5 Apply network adjustments 1-8

1.5 TeamViewer IoT activation 1-8

Team Viewer IoT tab 1-9

PC preparations – connected to the Ethernet port of the Management Level 1-9

Install IBHNet-IoT software 1-10 1.5.1 Opening the TeamViewer IoT Management Console 1-11

Assignment token dialog box 1-11

Insert assignment token 1-12

Assignment token taken from TeamViewer IoT 1-13

Copy the TeamViewer ID 1-13 1.5.2 Establishing a connection 1-15

Error messages starting process 1-16

Error messages starting the process 1-17

Activate the start process again 1-17 1.5.3 TeamViewer IoT – Logfile 1-18 1.5.4 Teamviewer IoT – MQTT settings 1-19

1.6 TeamViewer IoT License IBH Link UA 1-19

1.7 Security browser window 1-20

Server Security 1-21

Reverse Connection 1-21

Firewall 1-22

Web Configuration 1-22

1.8 Certificates browser window 1-23

1.9 Time settings browser window 1-23

1.10 System browser window 1-24

Page 4: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Page II Contents Version V5.20

.....................................

.........................................................................

......

...........................

..........................................................................

IBH Link IoT Training

.................

................................

...................................

..........................

..........

TTI Trans-Tech International© 2021

................................................................

.................

................................

..................

.........................

..........................................................................

.................

................................

..................................

1.10.1 Device information

.........................

..........................................................................

.................

................................

...............

1-25

................................

....................................

1.10.2 Backup and restoring the configuration

...........................................................................

......................................................................................

......

1-25

................................

.......................................................

Backup configuration

...................................

........................................................

...........................

1-25

................................................................

.........................

Restore the IBH Link IoT configuration

..........................................................

..........................................

1-26

................................

.......................................

Firmware Update

................................

.........................

....................................................

.....................

1-27

................................................................

.........................

1.10.3 Restart the IBH Link IoT

........................................................................

.................................................

................................1-30................................

.............................................

1.11 Diagnosis Browser window

................................

...........................................

.......................................................................

1-30

.....................................

........

Network diagnostics

................................................................

1-30

Download recording for evaluation with Wireshark 1-32

System logs 1-32

1.12 MicroSD browser window 1-33

1.13 IBH Link IoT default factory configuration 1-34

1.14 Open the Wiki 1-35

Open WIKI website 1-35

2 Access to controls (devices) connected to the portsof the control level 2-1

2.1 Remote IBH Link UA with connected CPUs 2-1

2.1.1 Local PC 2-1

2.1.2 Check IBH Link S7++ settings 2-3

2.1.3 Two or more IBH Link S7++ in one Subnet 2-5

2.1.4 Check IBH Link S5 ++ settings 2-6

2.1.5 STEP 7 Simatic Manager – CPU 416 S7e 2-8

Set interface 2-8

Status S7 CPU 416 2-8

2.1.6 STEP 7 Simatic Manager –CPU 312 S7e – 2-9

2.1.7 TIA Portal V16 – PLC 1500 TIA16e 2-10

Online & diagnostics – Online access window 2-10

Extended go online access – Online access dialog box 2-11

Search – Go online 2-13

Status CPU 1500 – data block CounterData [DB5] 2-13

2.1.8 PLC 1200 TIA16d – IP-Address 10.0.13.91 2-14

Online & diagnostics – Online access window 2-14

Extended go online access – Online access dialog box 2-15

Search – Go online 2-17

Status CPU 1200 – data block CounterData [DB5] 2-18

CPU 312 TIA16e– IoT S7++2 – IP address 10.0.13.26 2-18

Online & diagnostics – Online access window 2-19

Extended go online access – Online access dialog box 2-20

Search – Go online 2-21

Status CPU 300 – data block Counter Data [DB2] 2-22

2.1.9 CPU 416 TIA 16e – (IP-Adresse 10.0.13.9) 2-22

Online & diagnostics – Online access window 2-23

Extended go online access – Online access dialog box 2-24

Search – Go online 2-25

Status CPU 416 – data block CounterData [DB2] 2-25

S5 for Windows – CPU103-S5++ IoT – IP address 10.0.13.94 2-26

Status S5 CPU 103 2-26

2.2 Access to a PC - Remote Desktop. 2-26

Page 5: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Version V5.20 Contents Page III

..............................

...........................................

........................................

.............................................

............................................................................

TTI Trans-Tech International© 2021 IBH Link IoT Training

2.2.1 Preparation of IBH Link IoT and Server (PC) 2-27 2.2.2 Local PC (client) 2-27

Establish remote desktop connection 2-29

Remote computer Certificate verification 2-30 PLC Examples-Projects (PLC-Programs) III

PLC Examples-Projects (PLC-Programs)

PLC controlIP address Control

levelProgramming

system

CPU 416 S7e 10.0.13.11 STEP 7 Simatic ManagerCPU 312 S7e S7++1 / 10.0.13.25

PLC 1500 TIA16e 10.0.13.90

TIA Portal V16PLC 1200 TIA16e 10.0.13.91

CPU 312 TIA16e S7++2 / 10.0.13.26

CPU 416 TIA16e 10.0.13.9

S5 CPU 103U

Counter S5W.S5PS5++1 / 10.0.13.27 S5 for Windows

Page 6: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Page IV Contents Version V5.20

IBH Link IoT Training TTI Trans-Tech International© 2021

Page 7: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

1

nnnn

• *

Chapter 1 IBH Link IoT setup Page 1-1

TTI Trans Tech International© 2020

1 IBH Link IoT setup

1.1 Installation and connection

The IBH Link IoT is designed for DIN rail mounting:

The power is supplied via the included plug.

Power supply: 24VDC / 0.2A

IBH Link IoT Training

ATTENTION!

A supply voltage of 12VDC to 36VDC is to be used for the

operation of the IBH Link IoT. A higher supply voltage may

destroy the device.

The IBH Link IoT has two (2) interfaces,

which are separated by a firewall and

having separate MAC addresses, which

are designed for data exchange within

the management level or in the process

level.

The interface of the process level

consists of a 3-port switch.

Page 8: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link loT embedded

aTeamViewer Gateway Internet of •Th-n

Product no.: 3240 Serial no.: 001077

Power Suppty: 24VDC / 0.2Ä PI ta t Pl _L.

Ta: 0°C...+60°C vert. mounted Ta: 0°C...+40°C hor. mounted

Ethernet default configuration: Port 1: DHCP ' Port 2-4: 192.168.1.14

111111i1; softec Oberzent/Beerfelden, Turmstr. 77 D-64760

GERMANY www.iblisoftec.c,orn [email protected] +49 6068 3001

C E Made in Germany

Page 1-2 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

1.2 Configuration of the IP addresses (default setting)

With the IBH Link IoT default factory setting the configuration can be

done with an up-to-date web browser. The Ethernet ports 2 to 4 have

the IP address 192.168.1.14.

The Ethernet port 1 can only be used to configure the IBH Link IoT if

a DHCP server assigns the IP address, and a DNS server resolves

the name by specifying the hostname

http://ibhlink-iot_<serial number>

(Example: http://ibhlink-iot_001077)

No additional applications or drivers are required.

The following information is printed on the IBH Link IoT housing.

Default logon data

Username: admin

Password: admin

Page 9: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Management Level

Control Level

(Machine level)

■ IBH Link loT

- e 19.2.168.1.14/7_=J ••• Q erl 1111 El •: 0 E

single-core j

Login

The password is case-sensilive.

User name A.,[enter) Enter your user reine admin

Password , di enter Enter your password admin

Rememher me Keeps login for 2 weeks LJ

Login iddi(=),ck

Lost password

111111111111sottec tronvibhsoflec.coal Contact Wiki

IBH Link loT omborklad Yo.aorivicroogr C.Iteeeaw

TeamViewer Internet of Things

Chapter 1 IBH Link IoT setup Page 1-3

(e.g., 192.168.1.10).

TTI Trans Tech International© 2020 IBH Link IoT Training

Standard IP-Address configuration:

Level Port Address

Management Level Port 1 Hostname: ibhlink-iot_<serial number>

Control Level Port 2 - 4 192.168.1.14

1.3 Login browser window

Note:

With the IBH Link IoT default factory setting the configuration can be

made using an Internet browser (Microsoft Edge, FireFox, Internet

Explorer, etc.):

• Via the management level (port 1) with the host name if the port is

connected to a network with a DHCP server and DNS server.

• Via the ports of the control level. The connected network must

have the sub-address 192.168.1.nn.

Or the connected PC a has a fixed IP address from the subnet

192.168.1.nn

Page 10: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

r.adi 1242

Important information about HTFP access

With unencrypted connections, it is possible that personal information can be

revealed.

Therefore we recommend to disahle HUP in the 'Security' page.

Important information about the Password

; Currently a default password used

1. lt is highly recommended to change the

password.

IBH Link loT Network

E1 C

Network

(tonfirm1/2 6w.,

0 6 192.168.1.14/?_=/nehvork

Logout Update pa

a °gement Level Control Level Viewer 10

Update password Enier a new paßswold below

ad mit cannolbe changed

Passveord Ente! yOUF password

Choose Password valid

Repeat password valid

Ok Can.'

111111111111sottec wrvw ihsofleo com Contact Wiki

0

0

(confirm 1/21f0Tic

11•01riel

0

In m B :4 0 E

re

IBH,Fire loT

Tetter

Page 1-4 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Language selection

The languages English, German and

Japanese are available in the browser window.

Remember me

If this login is marked, no username and password will be requested

when the same browser window is called up again. This setting

remains in effect for up to two weeks.

Login

When you click Login, the following security messages are displayed

one after the other.

After the security messages have been confirmed, we recommend

changing the password.

Change Password

For security reasons, the password should be changed. The

username may also be changed.

In the open browser window Management level / control level klick

the button Update password.

Page 11: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Choose Password Too short 4.4111,4,11, 4.

■ 1,92 IBH Link loT - Network X

e er tele ele_i

[Network]

ü 11 Yti. fites

Time settings

I) Ei 192.168.1.14,f?_=inetwork +4.4.

Liiagnostics

MicroSD

Logout Update password.

r Management Level I

802.1X

Network Configuration

Endpoint URL or DHCP

IP address

Subnet mask

opc.tcp:Mbhlink-iot_001077:48010

-Global System Contiguration

Hostname ibhlink-iot_001077

Port 49010

Default gateway

Nameserver 1

Nameserver 2

Apply 1 Revert

11111111Bilsoftec vermibhsoftec.corn Contact Wiki

}

CO 0 :4 0 E

TearnViewer IoT

no ehanges possible if DHCP selected Wel

110 lijrn ' d Team i!.1

single-core

.e i . CITeamViewer

Internet-of Things

T

Chapter 1 IBH Link IoT setup Page 1-5

TTI Trans Tech International© 2020 IBH Link IoT Training

If the password is not long enough or

if you have not entered enough

different characters (A - Z; 0 - 9; special characters), the background

is "red". For security reasons, the password must be 12 or 16

characters long.

The browser access username cannot be changed.

1.4 Network browser window

1.4.1 Management Level Settings

Port 1 Network Configuration and Global System Configuration.

With DHCP disabled, the Network Configuration and Global

System Configuration may be modified. The hostname can always

be adjusted.

Note:

The management level (port 1) must have a different subnet

address than the subnet address of the control level (port 2 to

port 4) so that it is unequivocally which connection must be

established via which Ethernet interface.

Page 12: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

"

I8H Link loT- Network

192.168.1.14/7_=/fletwork ler Im ecoldE

• Network

Jurity

Certificates

settings

2m

liostics

Mic_

Logout Update password

C Management Level Control Level 802.1X

Network Configuration

Endpoint URL opc.tcp://ibhlink-iot_001077:48010

oY not marked DHCP

IP address

Subnet mask 192.158.178.14

255.255.255.0

Global System Configuration

Hostname

Port

Default gateway

Nameserver 1

Nameserver 2

ibhlink-iot_001077

48010 192./61179.1

192.169.179.1

113.0.13.1

tonfirm}_

Applyille(Revert

1111111113Hsoftec www.ibhsoftec.com Contact Wiki

>can be adjusted

TeomViewer IoT

IBH Link loT etnbet.lee, Tearnviewer GAtewav

TeamViewer Internet of etre 1

❑ X

III \ CD ® 0 E

single-co

Page 1-6 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

1.4.2 Setting the IP address - management level

By clicking the Apply button, the changed settings of the

management level are applied to the IBH Link IoT. Since the IBH

Link IoT web browser was accessed via the IP address of the control

level, the changes are displayed immediately after they have been

accepted. It is not necessary to reopen the IBH Link IoT web

browser.

The screen shot shows the settings of the management level for

access from an external PC.

1.4.3 Control Level Settings

The network configuration for ports 2 to 4 (control level) and global

system settings can be adjusted. If DHCP is deactivated, the network

configuration and global system settings can be changed. The host

name can always be changed.

By clicking the Apply button, the changed settings of

the control level are applied to the IBH Link IoT. The

execution of the change is displayed.

Since the web browser of the IBH Link IoT was accessed via the IP

address of the control level, access to the web browser of the IBH

Link UA can only take place via the changed IP address of the

control level or the IP address of the management level.

Page 13: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

1

■ IBH Link UA - Network

—> C'

MIN" Network

curity

40r , r4ificates

settings

io st cs

3

& 10.0.13.14,e_./ne.ork *

Update password

r Management Level If Control Level ir 802.1X

Network Configuration

TeamViewer IoT

Endpoint URL opc.tcp://ibhlink-iot:48010 • was changed cieseiected opc.tcp://10.0.13.14:48010 Or

DHCP

IP address

Subnet mask

10.0.1114

255.255.255.0

Global System Configuration

Hostname

Port

Default gateway

Nameserver 1

Nameserver 2

Apply Revert

1111111113Hsoftec www.ibhsoftec.com Contact Wiki

IBH Link loT

®-> e

ffleas ■CNetworkj

ibhlinkua_iot

48010

192.168.178.1 was changed

192.168.178.1

10.0.19.1

was changed

V P 10.0.13.14/?_=/network *

Logout Update password

Management Level Control Level TeamViewer IoT

802.1X-Security

Select 802.1X security Status Legitimation Identity

Select CA certificate (pem)

Upload CA certificate

Select user certificate (pem)

Upload user certificate

Select user secret key (key)

Upload user secret key

User secret key password

Deactivated Deactivated TLS

Browse... No file selected.

Upload CA certificate

Browse... No file selected.

Upload user certificate

Browse... No file selected.

Upload the user secret key

Save configuration

Global System Configuration —

Hostname

Port

Default gateway

Nameserver 1

Nameserver 2

Apply I Revert

IIIIIIIIBHsoftec www.ibhsoftec.com Contact Wiki

ibhlink-iot

48010

192.168.178.1

192.168.178.1

10.0.13.1

CD (2) 0

singto-core

IBH Link loT embed4.4

r:21 TeamViewer In te:•net o` Things

III\

single-core

Select the interface for 802.1X security or deactivate The current state Select the legitimation algorithm (currently only TLS) The username

Select the CA certificate in PEM format

Select the user certificate in PEM Format

Select the user secret key in KEY format

The pasword of the user secret key

0 IBHr.Linkt.loT

3 Internet

Chapter 1 IBH Link IoT setup Page 1-7

TTI Trans Tech International© 2020 IBH Link IoT Training

Control level with adapted IP addresses

The IBH Link IoT browser window was accessed via the IP address

specified at the control level. After logging in, the control level

browser window is displayed with the changed addresses.

The screen shot shows the settings of the control level for access

from an external PC.

1.4.4 802.1x settings

The IBH Link IoT provides IEEE 802.1X for authentication and

authorization in IEEE 802 networks.

Page 14: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

802.1X-Security

Select 802.1X security Status Legitimation Identity

Select CA certificate (pem)

Information

■ i

(open I select Select the interface for 802.1X security or deactivate

Management Level

Deactivated merk

Management Level

Control Level

Changing the hostname requires a rebnot_ Reboot Now?

(cor m\AhLok Cancel

Access to Control Level with TeamViewer loT via the Internet.

..14114x. /A

‘1,

Management Level

Control Level PLC controls, devices with

Ethernet Ports

— 0 X

ft * • Loading_.

CE

0

Page 1-8 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

The activated settings in the 802.1X window can be assigned to the

network connections at the control level or the management level.

The configuration of the IEEE 802.1X security settings can be saved.

1.4.5 Apply network adjustments

Click the Apply button to save the adjustments done in the

Management level tab, Control level tab, 802.1X tab, or

TeamViewer IoT tab. The Apply button should be clicked for each

tab separately. Confirm the displayed note to adopt the changes.

The transfer of the adjusted settings is displayed

in the upper right corner of the browser window.

Since the changes require a restart of the IBH

Link IoT, a corresponding information is

displayed.

1.5 TeamViewer IoT activation

The TeamViewer software is pre-installed in the IBH Link IoT. This

offers the possibility of being able to access almost all devices

(PLCs) connected at the Control level of the IBH Link IoT anytime

and anywhere.

Complex modem solutions

or the use of a PC on site

are a thing of the past.

To establish a connection

via TeamViewer-IoT, the

Ethernet subnet of the

Management level must

have access to the

Internet.

Page 15: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

(:›

■ gä IBH Link UA - Network X 1.1

0 10.0.13.14/?_=/network • • • C) III\ CD

Logout Update password single-core

Network)

Se 'dtv

C c

Dt C S

1,11u.D

r Management Level

TeamViewer loT r Control Level 802T.F1 reeamViewer IoT1

Status is reported back by

TeamViewerl D WT amViewer loT

Assignment Token

Group

TeamViewer auto start

Log level

Proxy settings

Proxy address (IP:Port)

Internet access over proxy

Info s, }hasto be configured

Start I Stop I New assign I Remove assignmert I Download logfite I Delete logfite I MQTT settings

Global System Configuration

Hostname ibhlink-iot Port 48010 Default gateway 192.168.178.1 1 Nameserver 1 192.168.178.1 Nameserver 2 10.0.13.1

Apply I Revert I

IIIIIIIIBHsoftec www.ibbsoft3c.com Contact Wiki

.0 IBH Link loT emb146.4 Twmviever

0 TeamViewer Internet of Things

About TeamViewer X

Version: 15.13.6 (32-bit)

Date: Dec 142020 14:35:50 TeanWiewer ID: 1000.000000

Chapter 1 IBH Link IoT setup Page 1-9

TTI Trans Tech International© 2020 IBH Link IoT Training

The IBH Link IoT manages two subnet addresses separated by a

firewall, each with its own MAC address.

Ethernet areas:

Level Port

must be in different subnets

Management Level Port 1

Control Level Port 2 - 4

Team Viewer IoT tab

If the Internet must be accessed via a proxy, the address can be

entered in the form Proxy: Port or User: Password @ Proxy: Port.

The proxy access to the Internet must be activated.

PC preparations – connected to the Ethernet port of the Management Level

To use the access options of the pre-installed TeamViewer IoT

software, the following conditions must be met:

TeamViewer software version 15.13.6

or newer must be installed on the PC

that is to be used to access the external

IBH Link IoT.

Page 16: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

-

Connection Extras Help Feedback

Sign In

Don, have an account?

Remote Control

>r, Remote Management

••• t1.1 Meet.

1=113 egi Cha

Augnnented Reality

Getting Started

3 TeamViewer

Info about IBHNet-lol

Passmercl

S gn In

o Keep rne signed in

Forgot password

Sign Up

Single Sign-On Logln

• Ready to rennen (secure connection,

01311Net-IoT Agent 41.11)

IBHsoftec Gesellschaft für Automatisierungstechnik mbH

Turmstrasse 77 D-64760 Oberzeneeerfelden

Phone: +49 6060 3001 Fax: +49 6060 3074

[email protected] wmalbhsoftec.com [email protected] mlellehsoftec.com

rick OK Copyright (C)IEHsoftec GmbH 1993-2021

•-* ' .nnect

Aus

you already a TeamViewer

tmer?

Please sign in here with your TeamViewer

account to use the full functionality.

IBHNet-loT

i 113HNet - loTTray - 113Hsoftec GmbH

Ready

16:30

l i ' e 1̀' 2020-09-03 1 1

IBHN et-I dr Tray - IBH softec GmbH Service stopped

•v. e L [1'

16:30 2020 -439 - 03

i IBHNet-loTTray - IBHsoftec GmbH Sent:10604 Received:10433

13.36 1- 1 e 2020-11-23

Page 1-10 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

A TeamViewer account with a corresponding license must be ready

for activation.

Install the IBHNet-IoT-Setup.exe software on the PC. This software is

available for download at

https://download.ibhsoftec.com/neutral/IBHNet-IoT-Setup.exe

It is important that the latest

software version of the

IBHNet-IoT Agent is always

installed.

Install IBHNet-IoT software

Double-click the IBHNet-IoT icon created during

installation. The ibhsoftec-agent-service is

started.

The service is displayed in the IBHNet-IoT Tray

in the task bar. It may be necessary to change

the properties of the taskbar to display the icon.

Pointing to the icon, displays the

readiness of the service.

If the symbol indicates a stopped

service, it must be started.

Once the connection has

been established, the IBHNet-

IoT tray symbol has a green

corner at the bottom left and

transmission data is displayed

Page 17: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

TeamViewer Management Coi X

e er ä https://loginteamviewerscons/Logen/PapUpficereturnUr1=%2' ••• Cr I III \ CD e E

Free loT 8 Connect AnyThing, AnyWhere, AnyTime

Whether you're lccated an Greenland or in downtown Manhatten, have a million-clollar budget or just a great idea, TeamViewer lets you jurnp-start your loT journey with free access to a maximum of 2 loT endpoints.

Share this

0 0 0

EI Tee ter

TeaniviewerlOTHOMB

DRICF,IMMARY

Meers

0 0

fl fl

3111:11111

Datunenteen

Cethng Seiof

0 10

Assignmenttoken

Mrigneriblaneusdbammilhedemze-becatuorrl.

5-C ei.

1.1001111

0

O TeamViewer Internet of Things

Sign In hont have TeamViewer account yet? Sign up here.

Email

[email protected]

Password to compeete

Keep me signed in

Sign In

Forgot password?

Iß 0m 0 E

et

ao .>

[email protected] Engllsh Contacl Us

Lisenseil

Assignrnenttoken (acky

10 0- < 0

Assignment token

Help

API Key

Assignmen1-104:en

Log 001

Assignment loken is used to assign the device to the account.

Renew anklicken

Veit. Copy

anklicken)

1..1011131anaril

Chapter 1 IBH Link IoT setup Page 1-11

TTI Trans Tech International© 2020 IBH Link IoT Training

1.5.1 Opening the TeamViewer IoT Management Console

Use the link https://teamviewer-iot.com/en/ to open the TeamViewer

Internet of Things login page and log in.

After logging into the TeamViewer IoT Management Console, open

the Assignment token dialog box.

Assignment token dialog box

Page 18: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

V

uniCIM Copy

I8 IBH Link UA - Network X

0 -> 10.0.13.14/?_=/network

r.7e1M -411 Logout r Update password

Network]Security

Certificates

tics

YYCY

Management Level 1 I Control Level

TeamViewer loT

Status is reim'"by

TeamViewerlD TeamViewer loT

Assignment Token

Group

TeamViewer auto start

Log level

Proxy settings

ler ± IiI\ CD ®

single-core

802.1X CTeamViewer

re Copied Assignment tokert i

TTi to complete 2 open1eele Info " If the log level is changed, the TeamViewer agent 1

must he restarted to apply the changes.

Proxy address (IP:Port) fitl in if necessary

Internet access over proxy

C121.31

Start I , Stop I , 1110W assign 1 , Remove assignment I Download logfile I iDelete logfile I MQTT settings

Global System Contiguration

Hostname

Port

Default gateway

Nameserver 1

Harnesen/er 2

Apply1 Revert1

1 111111111111sottec wywvibhsoftec.com Contact Wiki

ibhlink-lot

48010 I

192.168.178.1

192.168.178.1

10.0.13.1

TeamViewer® IoT End-User License Agreement

TeamViewer® loT End-User License Agreement

You find the Full version of the loT EULA here => http://wmv.teamviewercom/link/?ur1=653670

This End-user License Agreement including its Annex ("EULA") applies to you and TeamViewer Germany GmbH ("TeamViewer" or "We") for the licensing and use of our software, which includes the TeamViewer software and all versions, features, applications and modules thereto ("Software"). This EULA also covers any associated media, printed materials and electronic documentation that we make available to you (with our Software and "Product"). Future releases of our Product may warrant amendments to this EULA.

BV CLICKING "ACCEPT", DOvvHDI, D1[16 OR OTHERWISE USING OUR SOFTWARE, YOU AGREE TO ALL TERMS AND OHDITIONS OF THIS EULA. IF YOU DO NOT AGREE TO AN OF THE TERMS OF THIS EULA, PLEASE IMMEDHÄTELY PETUP[1, DELETE DR DESTROY ALL COPIES OF OUR SOFTWARE IN YOUR POSSESSION.

If you want to use this software, you have to agree to the terms stated in http://wKetteamviewercom/link/?ur1=653670

(confirrn>.,k, Accept Reject

• IBH Link loT embedded reamview er GaltIWAV

TeamViewer Internet el Things

cl ick

An assignment token and a group name must Ire provided to aS5 i g n the device to TeamViewer.

Page 1-12 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

By clicking the Copy icon, the Assignment token,

shown with several dots, is copied to the Windows

clipboard.

Insert assignment token

The Assignment token must be copied into the field with the same

name in the IBH Link IoT browser window Network/TeamViewer IoT.

Enter the group name and mark that the TeamViewer is switched on

automatically.

Clicking the New assign

button opens the

TeamViewer IoT End-User License Agreement.

Page 19: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Toner

Accept

Assignment active

Progress:

Activating TeamViewer connection

• IBH Link UA Network

® e

[Network)

Security

Certificates

Time settings

System

Diagnostics

MicroSD

10.0.13.14/?_=/nehvork

( Management Level

TeamViewer lo

Status

TeamViewerlD

Assignment Token

Group

Team‘inver auto stad

Log lsvel

pety sehmga

Prag), address OP.Pod)

Internet access mar grimm 2

Control Level I I Mg .) (

7222222222

Info

reporma bam Im Teereviewer mr

— ❑

e 0

TeamViewer loT

Start Stop [New 7h 1, Remove assignment Download logfile Delete logfile NIQTZattina,

Global System C nfigurati n

ostname

an

Default gateway

ameserver 1

ameserver 2

Apply Revert

1111111111Hsoftec wrvw ibbsoftec com Contact Wiki

• IM ICH Link 04 -Network

(I) e

1

1:211=2111 Security

Certificates

Time settings

System

Diagnostics

MicroSD

CD 10.0.13.14/?_=/network

lthink-1ot

98010

192.160.170.1

192.168.178.1

Logou Update password

Management Level

TeamViewer loT

Status

TeamViewerlD

Assignment Token

Gmup

TeamViewer auto statt

og level

Pro,y sellings

Proxy address (IP. Port)

TTI

2 Info

gogY

113H Li

O

— ❑

± III \ m Z) 0 E

Internet access over prosy ❑

Chapter 1 IBH Link IoT setup Page 1-13

TTI Trans Tech International© 2020 IBH Link IoT Training

TeamViewer IoT End-User License Agreement

To apply the settings, the TeamViewer IoT end

user license agreement must be accepted by

clicking the button Accept.

The online connection to the TeamViewer IoT server is established.

Assignment token taken from TeamViewer IoT

If the assignment token has been accepted,

the status and the TimeViewerID with the

name are displayed in the web browser

window Network/TeamViewer IoT.

Copy the TeamViewer ID

Copy the TeamViewer ID number to the Windows clipboard.

Note!The transmission of the Assignment token to TeamViewer can

take some time.

Page 20: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Close TeamViewer connection,..

Agents...

Help... " 1(click)

Homepage...

Informaticn...

Klose IEHNIet-loTTray

jriglit Mick

1620 11 et (1) 2020-09-03

Teamviewer-Shortcuts X

Connection

Display name Teamviewer-URL

IBH Link IoT teamviewer8://remotecontrolihemotecontrolid=22222222228iforwardports=[31711:localhost:31711:3] is inserted

Connection

Display name: IBH Link IoT freery selectable

Teamviewer ID:

4 oliok

2222222222 insert(I)

Add to list I Remove from list

Oconfirn

Properties OK Cancel

Properties X

Language

German cv: Egg

Ethernet card with Internet Access

'GIntee) Ethernet Connection (2) 2193

—Teamviewer Connection establishrnent

Local Port [31711 Timeout 110000

confimt

OK Cancel

Page 1-14 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Right-click on the IBHNet-IoT Tray icon to open the context menu.

The Agents… command opens the TeamViewer Shortcuts dialog

box.

Insert the TeamViewer ID number in the field of the same name.

The display name is transferred to the TeamViewer account. This

name can be used to establish a connection to the IBH Link IoT via

the Internet.

Clicking the Properties button, a dialog box appears with the details

of the network card via which the IBH Link IoT is connected.

By clicking the Add to list button, the display name and the

TeamViewer ID are adopted. The dialog box is closed with OK.

The installation of TeamViewer IoT in the IBH Link IoT is now

complete.

Page 21: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

TeamViewer

Connection Extras Help Feedback

Pete loT

Q Search

Recent Connections

+-4 Remote Control 9 ibhlink-iot

9 ibhlinkua_sc

X Remote Management 9 V Meine Computer

(IILINI Meeting TTI

9 ibhlink-iot

El: Computers & Contacts 1111 ibhlinkua_sc

I> Offline (2)

cp

Chat

Augmented Reality

TeamViewer • Ready to tonnett (secure connection)

TeartWiewer

❑ X

Insert partner ID Connect •••

IBH Link loT eck)

Close TeamViewer connertion...

Agents...

Help...

Homepage...

Wiki...

Information...

Ciose IBHNet-IoTTray

i iright dicke IBHNet-IoTTray - IBHsoftec GmbH Ready

16:30

(I) 2020-M-03 L

Chapter 1 IBH Link IoT setup Page 1-15

TTI Trans Tech International© 2020 IBH Link IoT Training

1.5.2 Establishing a connection

A connection to the IBH Link IoT and thus to the PLC controls and

other devices that are connected to the ports of the control level can

be established via the Internet from any PC.

The IBHNet-IoT software must be installed on this PC.

TeamViewer must be started, and you have

logged into the TeamViewer account.

Registered TeamViewer IoT account.

Right-click on the IBHNet-IoT Tray icon to open the context menu.

The devices registered with the TeamViewer account are listed in

the upper area of the context menu.

The connection is established with a click on the desired device (IBH

Link IoT).

Page 22: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Progess

ead current configuration

— Comected ageit

Rernote=ibblinkuasic Address =10.0.13.99 Mask =255.255.255.0

r Progress

Configuration complete

— Connected agent

Lemote=bhlin ot Address=10.0 4 talask=255.255.25 31

istening port: 31711 allonied ips: 192.168.179.0/24 OK CanCel

r Network Connections

.o All .., k Netw...

Orgernze »

jr - IBHNet-loT lere IBHNet-lciT

lerWreGuard Tunnel

TL-Net NTP-N et Intel(R) Ethernet Connection (2) 1...

4 items 1 item seleded

v

a 0

0 ibblinkua_qc- feanwiewer -

gnie transfer Remote AppControl Port Forwarding

Login

User name Enter yourusernarne adnirn

Password

Rernemberme Ke fl emri weerts 2

Login1PC

Lost oassword

111111111illsoftec rww.ibbsofteccom Contact

IBH Link UA

Page 1-16 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

The establishment of the connection is displayed.

After the connection has been successfully established, the IBH Link

IoT appears as a WireGuard Tunnel under the network adapters of

the PC.

From now on, all controls and devices that are connected via the

Control Level of the IBH Link IoT can be reached.

Error messages starting process

Note!

Windows use two names for network

adapters, the Name given by the

Hardware or the FriendlyName.

• WireGuard Tunnel

• Wintun Userspace Tunnel

The different names are therefore

displayed in the screenshots.

Page 23: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

TeamViewer

Connection Extras Help

Pete

Remote Control

Remote Management

Starting Teamviewer Mo

Feedback

TeamViewer Authentication

O Please enter the password that is displayed an your partner's computer.

Password;

0 Advanced Log On Cancel

Tearnviewer stark progress

Co

Ch

Augmented Reality

My Computers

TeamViewer Authenticating...

IBH Link loT

Close TeamViewer connection...

Agent...

Help..

Homepage...

Wiki...

Information,..

Close IBHNet-loTTray

76%

IBHNet-loTTray - IBHsoftec GmbH dight clicleReady

16:30 ,N In lt Ek IfU <1) 2020-09-03 L.-1

13 X

r'isert partner ID Abort

leise

GMD

Cancel

wll

IBHNet-IoTTray - IBHsoftec GmbH Service stopped

Chapter 1 IBH Link IoT setup Page 1-17

TTI Trans Tech International© 2020 IBH Link IoT Training

Error messages starting the process

Activate the start process again

After the connection has been successfully

established, the IBHNet-IoT Tray icon in the

taskbar changes. It gets an additional green mark.

From the PC, whose IBHNet-IoT Tray Icon

shows the existing online connection, controls

(CPUs / devices) connected to the Control level

Note!During the TeamViewer start process it may happen that no

connection is established, and the error messages are displayed.

These error messages are to close with Cancel.

The starting process must be started again.

Page 24: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

(.open seiect

1,3,1,31 Info

Verbose

Info

TeannViewer

If the log level is changed, the TeamViewer agent musst be restarted to a p ply the chan g es.

1 If the log level i .hap-Jeci, the Te rriVievver be restarted to apply the changes.

(contirrn

Eci...yri load Ii:u Delete logfile MATT settings

(dick.Download the TeamViewer logfile for detail led inspection.

C:\Users\TRAppData \ Local \Temp\teamviewer-iot-agentjogfile.log.txt - Notepad++

File Edit Search View Encoding Language Settings Tools Macro Run Plugins Window ?

GAeusee,14gbalaclit%"-t ,tica lE,, 8 teamviewer-iot-agent_logfile.log.txt

22 Version: 23 ID: 2027546790 24 Loglevel: Info• (100) 25 License: 10000 26 Server: master7.teamviewer.com 27 IC: 1759993539 28 CPU: ARMv7•Processor•rev•10• (1, 71) 29 OS: Lx•The•Yogurt•Distri• (armv71) 30 IP: 192.168.178.89,10.0.13.89 31 MID:

beehive01ee6b78950b1fa9d4 502df4199d16<16f12cbbc5049298cf299c31e2848681175540699 7226130329afcb6d381dd71

32 MIDv: 1 33 Proxy—Settings: Type=0•IP=•User= 34 35 2020/12/2710:19:57.250• • •349•3070046224 NetWatchDogLinux. •using•RTLink•event•handler 36 2020/12/2710:19:57.251• • •349•3070046224 RemoteSettingsMDRelationshipWatchDog. •Device•is

a•managed•device

Normaltextfile length:111468 lines :163 Ln :1 Col : 1 Pos :1 Unix (LF) ULF-8 INS

81110►EIZi le

Ves

Page 1-18 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

ports can be accessed with the appropriate software (programming

system).

If the online connection to the IBH Link IoT cannot be established

because a required service has been stopped, this will be displayed.

1.5.3 TeamViewer IoT – Logfile

The log output can be adjusted.

The log output selected is stored in the IBH Link UA.

By clicking the Download logfile button, the saved states of the

TeamViewer IoT connections (error-free / faulty) can be displayed in

an editor or saved as a text file.

Since the evaluation of the log-file requires some specialist

knowledge, this diagnosis should be carried out in the event of a

malfunction using the IBHsoftec hotline.

To have a defined beginning of the log file, the stored file can be

deleted.

Page 25: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Open a dialog with MC1TTsettings for the TearnViewer cloud

MQTT settings

Establish connection to the TeamViewer IoT Cloud x

Connection to TeamViewer loT

Activate connection 2

Client Id:

Topic:

Create Cerbficates for the Client

Download the TeamViewer Aulhority Certificate

Download Certificate for the Client

Download private key for the Client

Ok

TeamViewer IoT

If the connection to the TeamViewer loT Cloud is changed, the TeamViewer agent nust be restarted to apply the changes.

Yes

Chapter 1 IBH Link IoT setup Page 1-19

TTI Trans Tech International© 2020 IBH Link IoT Training

1.5.4 Teamviewer IoT – MQTT settings

The MQTT option is only useful in conjunction with the IBH Link UA

from IBHsoftec.

Clicking the MQTT button opens the Establish

connection to the Teamviewer IoT cloud dialog box.

Details on the use of MQTT with the IBH Link UA is described on the

IBHsoftec WIKI website.

1.6 TeamViewer IoT License IBH Link UA

With the latest, freely available firmware the functionality of the IBH

Link UA is extended, to allow remote maintenance via TeamViewer

IOT.

This new feature allows to access nearly all PLC systems always and

everywhere.

Complex modem solutions or the use of a PC on site are obsolete.

To use this functionality with IBH Link UA, you need a TeamViewer

IoT license.

Use the following link to purchase a TeamViewer IoT license:

https://wiki.ibhsoftec.com/en/IBH_Link_IoT:TeamViewer_IoT_License_IBH_Link_UA

Page 26: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

®4 IBH Link UA - Security El X

o j 10.0.13.14fi_=fsecurity — 0tr III% CD ® 0

Logout Update password

Network

Securiti-rj

Time settings

System

Diagnostics

MicroSD

Server Security

2 None (not recommended)

3 Basic128Rsa1 5 (not recommended)

3 Basic266 (not recommended)

Basic266Sha256

gAes1213Sha256Rsa0aep pAes256Sha266RsaPss pPermit Anonyrnous Access without User

Authentication 3 Let a Client connect if the hostname in the

certificate does not match (not recommended) 3 Let a Client connect if the date in the certificate

does not apply (not recommended)

Reverse Connections

Add reverse connection Remove reverse connection

Firewall

3 Permit only OPC UA an Management Level

Webronfiguration

Permit HTTP access for the Webconfiguration

3 Use custom Certificates

Start creating new Keys

APPIY Revert

11111111Ellisoftec www.ibhsoftec.com Contact Wiki

APPIY Revert

Sign

Sign + Sign and Encrypt

Sign + Sign and Encrypt

Sign + Sign and Encrypt (Default = On)

F2pload Server Certificate

Generate new Keys

111 libeetlilialielr

0 Tea rnVi ewe r inernel of Things

(elick),„äh. LAPPIY

Page 1-20 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

1.7 Security browser window

The connection security between a client and a server is available for

selection in this window and can be specified.

The client queries the server's security configuration via

SecureChannel to then set up a communication channel in which the

security (confidentiality) and the completeness (integrity) of the

messages exchanged are guaranteed.

Note:

Encrypted messages prevent or at least make it exceedingly difficult for

untrustworthy third parties to read the content of the messages that are

exchanged between the OPC client and the OPC server.

Note:

After changes made in the security browser window, the buttons

and are activated.

If the change is to be adopted, click the Apply button.

Page 27: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Server Security)

2 None (not recommended) DBasic128Rsal5 (not recommended)

❑ Basic256 (not recommended)

2 Basic256Sha256 2 Aes128Sha256RsaOaep 2 Aes256Sha256RsaPss

0 2 Permit Anonymous Access without User Authentication

[❑ Let a Client connect if the hostname in the certificate does not match (not recommended)

❑ Let a Client connect if the date in the certificate does not apply (not recommended)

Sign

Sign

Sign + Sign and Encrypt •••• Sign Sign + Sign and Encrypt

(Default = On)

(open '

Sign

Sign

Sign and Encrypt

Sign + Sign and Encrypt

Chapter 1 IBH Link IoT setup Page 1-21

TTI Trans Tech International© 2020 IBH Link IoT Training

Server Security

There are different levels of encryption.

Is the security level for the client / server connection selected, in

addition the levels Sign, Sign and Encrypt as well as Sign + Sign

and Encrypt can be selected.

The security level is set by opening and

selecting.

Sign The messages contain security signs. It is

signed with the associated Private Key

of the Application Instance Certificate

of the client. Signed messages can detect

whether a received message has been manipulated by an

untrustworthy third party.

Sign und Encrypt The messages contain security tokens and are

encrypted. They are also encrypted with the Public Key of the

Application Instance Certificate of the server.

Sign + Sign and Encrypt The messages contain the security labels of

Sign and additionally those of the Sign and Encrypt definition.

Anonymous access without user authentication is allowed as a

standard and can be deactivated.

Settings can be made to allow client / server connections for security

reasons not recommend.

However, it has been shown that in some applications these settings

are unavoidable to establish a client / server connection.

Reverse Connection

In contrast to conventional client-server connections, in which the

client establishes the connection with the server, in the Reverse

Connection the server actively connects to the client.

An inverse server connection can be set up if the server is in a more

protected area behind a firewall than the client. To do this, enter the

Page 28: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Reverse Connections—

opc.tcp://192.168.1.14:48010 is inserted

Add reverse connection 1 Remove reverse connection

dick

Reverse Connection

Endpoint opc.tcp://192.168.1.14:48010 enter)

confirm

OK Cancel

Firewall

❑ Permit only OPC UA an Management Level

Webconfiguration

g Permit HTTP access for the Webconfiguration

Eluse custom Certificates Upload Server Certificate

Start creating new Keys 0 Generate new Keys

O ' upioaa Server Certificate

Page 1-22 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

endpoint URL of the client. This makes it easier to configure the

firewall. Of course, the client must support incoming server

connections.

Firewall

The firewall can be instructed to allow OPC UA connections on the

management level only. With a web browser it is no longer possible

to address / configure the IBH Link IoT via the management level

(Ethernet port 1).

Web Configuration

For security reasons, the configuration should only be accessed

using the secure transport encryption (HyperText Transfer Protocol

Secure - HTTPS).

Therefore, the option Permit HTTP access to the web

configuration should be deactivated.

All IBH Link IoT have the same parameter set

for negotiating the keys for encryption. This is usually not a problem.

However, it is possible to create a new parameter set for the

encryption.

If Use custom certificates is selected, a dialog box is opened via

the Upload Server Certificate button. Buttons are available for

searching, reading in, and installing the Server Certificate and

Private Key.

The button Generate new Keys opens a message that must be

confirmed to generate a new key.

The note must be observed, as the generation of a parameter set for

negotiating the keys for the encryption can take several hours.

Page 29: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

ON

■ ICH Link LIF, - Certificates X

Oe e

Network

Security

Certificates

10.0.13.14/?_./ceente Oft Iß CD 9 0 :Y E

smgle.coreir

Status Name Valid From Valid To Organization

E Server IBHIrkUelbhlInku.3_... 03/16/20 17:17:45

Trust RBJBC VIew Delete USW Server Certfficate

Time settings Download Cerecate for Ute Chent e

System

Diagnostics

MicroSD

03/15/25 17:17:45 Organization

Replace Server Certfficate Upload Certfficate from Chent or CA

Organization unit

Unt

Crenteanevxrvereertifirnte.All conneded clientsmuattruatthenea cerbficäteägän

Importani Information about date and time settings

CedlfiCAS will only work proper, If the 0100k Ia set correctly. Tour device repotts

2020-09-21 17.45.06

You should contInue only, lf the date and time settings are correct Othemse the Glock should be set fest.

Confinup9

11111111131k esoftec com Contact W1k1

am Cancel IBH Link loT nkedid*Ordlemy

TeamViewer wenretalihng

Chapter 1 IBH Link IoT setup Page 1-23

TTI Trans Tech International© 2020 IBH Link IoT Training

1.8 Certificates browser window

Certificates can be created, downloaded, or read into the designated

certificate store.

The existing certificates with data and status are displayed in the

window. Buttons are provided to trust, block or delete listed

certificates.

1.9 Time settings browser window

The date and time can be entered manually or automatically via the

time server.

Note:

The generation of a parameter set for negotiating keys for encryption

may take several hours.

Note: If a change has be made in the Time settings browser window the Apply

and Revert buttons are activated.

If the change is to be adopted, click the Apply button.

Note:All settings that can be made in the Certificates browser window

are intended for future firmware upgrades and are currently of no

significance.

Page 30: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

1111 ICH Link LIA-Tmese■ g-ree

Network

Security

Certificates

«fi rne settingsj

System

Septerbe

Mon T ed Thu

31 2

2020 »

Fr Sa un

54

Diagnostics 9

14 20

MicroSD 22 23 24 25 2726

28 29 30 2 3

5 7 8 9 10

mg, -

3 H 10.0.13.14/3_, ,thatear ckm, in 0 e 4 0

r Time 6 i135n s

et date and firne

Show firne In CTG

-firne 17,56,25

1 renete refed st t when poll reach delay effset setter

l ime =9 ersetunes

Get time from NTP semer

NTP Server et1

NTP Server 5,2

NTP Server 553

NTP Server 664

2

Rporstnectsrg

1.porstrrectsrg

2.perc1.nemorg

3.perc1.nemorg

Anolv Feuert I Show NTP statts6IdeM

IIIIIIIIBHsoftec wsvaibhsoflec cern Contact Wiki

+2a01.498:017:64 147.231.2.6 2 21 29 64 377 94.980 1.056 0.178

11319 bot UA-System ■

->cee

Network

10.0.13.14/7_, 42ockuprectors

091-[ .., 1

In 3 0 0

00399 in1 rrnafiSecurity Firmware Versinn [IBH Unk LA V5.211 Dec 29 2020 16 39 56]

Certificates Serial number 107711W neision [ 2.0.1 mag single-core 1

Time settings MAC address 1 50:20:54'.10:3C:22MAC addreee 2-4 50:20:F.1:1C:21:2A

System ) CPU lud 1%) 7.8

Diagnostics Mer, orY o sage (%) 25.0Temperature (°) 40.3

MicroSD VBAT 6V 5.03VVIN_24 23.92V

IBH Link loT P71 TearnViewer uzu

-

Backup and Rest re settings

Configureen Erle

Restore

Backup

Firmware Update Select fi rmware Eile

Upload Fmnware

Restall IBH Link UA

Reboot Reboot Restarts the derice All communcabon wich PLCs and OPC UA Chents will he taterrupled Chck only, if you are absolutoly sure

No fileseleded.

Downloch

Ne fik ededed.

Uploah Fmmeere

Configurahon fi le to testete previously earred settings. Typmali),

the (de narre I3. hohlmIsua-settingsAml.

Arier downloadms the configuratfion Erle Mhfinkoamettmes.sml, it la possäle to perform a furmvare update.

FIrmurere Hie ta perforrn en update Typically the tue narre

IM,Ilnkua-uptlataA3,3-rerision-type tat

APO,'

Page 1-24 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Clicking on NTP status displays the status of the transmitting time

servers with their IP address. Four (4) Time Servers are already

specified.

1.10 System browser window

The system browser window lists information about the IBH Link IoT.

Page 31: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

System

Device information

Firmware Version Serial number HW revision MAC address 1 MAC address 2-4 CPU load (%) Memory usage (%) Temperature (CC) VBAT_5V VIN_24

CIBH Link UA V5.20 Dec 28 2020 16:39:561 1077

r 2.0.1 imx6 single-core] 50:2D:F4:1D:3C:22 50:2D:F4:1C:21:2A 7.8 25.0 48.3 5.03V 23.92V

Firmware Version IBH Link UA V5.17 Nov 20 2020 13111:42

Serial number 1077

HW revision 2.0.1 imx6 single-core

MAC:: s

fiflAC address 2-4

CPU load

Memory usage (%) Temperature (°C) VBAT 5V VI N24

50:2D: F4:10:30:22

50:20:F4:1C:21:2A

8.8

25.0 48.3 5.03V 7, 3 GI

Download

Chapter 1 IBH Link IoT setup Page 1-25

TTI Trans Tech International© 2020 IBH Link IoT Training

1.10.1 Device information

Firmware version

The version number is important for the firmware update. Only a

firmware update with a higher version number should be carried out.

Serial number

The serial number gives the IBHsoftec hotline information about the

series and the age of the device.

HW revision

The HW revision specifies with which firmware version (HW2 SC or

HW2 QC) an update can be carried out (see page 1 - 22).

MAC addresses

The IBH Link IoT has two

separate MAC addresses.

One MAC address for the management level and another MAC

address for the three ports of the control level.

Hardware information

The current CPU load (%), Memory

usage (%) and Temperature (°C) as

well as an internal voltage (VBAT_5V)

and the supply voltage (VIN_24) of

the device are displayed.

1.10.2 Backup and restoring the configuration

In this field there are buttons to save or restore the IBH Link IoT

configuration. The backup function must be carried out prior the

firmware update.

Backup configuration

To save the configuration, click the Download button and

select Save As in the opened dialog box.

Page 32: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

[Backup and Restore settina

Configuration file

Restore

Backup

Firmware Update: Select firmware File

Upload Firmware

Browse... No file selected.

Upload Configuration]

Downtoadlig(diel.

Browse... No fi t

Upload Firmwa

Configuration file to restore previously saved settings.

Typically the file name is ibhlinkua-settings.xml.

After downloading the configuration file ibhlinkua-settings.xml, it is possible to perform a firmware update.

After downloading the configuration file ibhlinkua-settings.xml, it is possible to perform a firmware update.

ioniainud-upudi.e-vw, evisiurHypeun.

Opening ibhlinkua-settings.xml X

You have chosen to open:

ibhlinkua-settings.xml

which is: Extensible Markup Language (XML) from: https://10.0.13.14

What should Firefox do with this fRe?

(j_Qpen with

• Save File

mark (clickOK Cancel

4 Enter name of file to save to... X

This PC > Workshop (A) > IBH Link-loT Search 18H Link-loT

Organize • New folder

, Workshop (k.)

IBH Link-loT

File name

Save as type

Hi de Folders

Name Date modified Type

ibhlink-iot-settings.xmlnt 2020-09-21 19:32 XML File is inserted

v

ibhlink-iot-settings.xml is entered, can be changed

rot m

Backup and Restore settings

EConfiguration fite) Browse...

No file selected.

File Upload

No fite selected.

stick

L Browse.,. 1

o n fhti

PEE •

Size

45 KB

Save Cancel

Configuration file to restore previously saved

settings. Typically the file narrte is ibhlinkua-settings.xml.

s This PC Workshop (Pu) > IBH Link-loT v )0 Search IBH Link-loT

Organize v New folder

sr Workshop (k)

IBHI Link-loT

File name

Name

gEE -a 0 Date modified Type Size

ibhlink-iot-settings.xml 202049-21 19:32 XML File 45 KB

ibhlinkua-settings.xml 2520-09-21 19:41 mark)

v

XML File 45 l<13

ibhlink-iot-settings.xml je Insert" Extensible Markup Language (confirm)..k

2. pen Cancel

Page 1-26 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Specify the path and filename in the Save to dialog box and confirm

by clicking Save.

This procedure saves the existing settings.

Restore the IBH Link IoT configuration

An already saved configuration can be restored.

Click the Browse button. The File Upload dialog box

opens.

Page 33: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Backup and Restore settings

Configuration file

Restore

Backup

Etrowse.„ is inserted

Qhfink-iat-settings.xmll Configuration file to restore previously saved gettinng Tvnirallu thp file namp iG ihhlinkna-

After a configuration file to restore the settings has been selected,

Upload Configuration it must be uploaded, before it's contents can be applied.

Download

Information

IAH IBH Link UA - The latest Firmw

toi

Homepage

11‘.(BFri ceAfter downloading the configuration file ibhlinkua-settings.xml, it is possible to perform a firmware update.

Restoring the configuration X

Progress:

0%

Applying the configuration requires a reboot. Reboot Now?

(confirrn )9111f0Tic Cancel I

di https://www.ibhsoftec.com/epages/63444704.sfien_GB/?ViewObjectPath.' •••

ec Homepage » Download » IBH Link UA

0 About us IBH Link UA 1.3 Products

Support

ce,ownload 44mark) Description

O S5/S7 for Windows 0 IBH Link loT O IBH OPC UAServer/Client 0 IBH OPC UA Editor

O IBH OPC Server 0 SoftPLC S7

O SoltPLC S5

CO IBH Link UA 0 IBHNet/ IBH Lin

dick

0 USB-S7 Adapter

0 IBH USB-S5 Adapter

0 S7-PCI315 O S7-CX315 / S7-CX317 0 USB S5/S7 Prommer

• IBH Link UA

Download Link

select according to the IBH Link loT hardware IBH Link UA Firmware V5.20 HW1

L ..1111V.In1111.311

Contact n Your basket is empty. S Ei

Administration via web browser. IBH Link UA Firmware V5.20 HW2 SC

IBH Link UA Firmware V5.20 HW2 QC

IBH OPC UA Editor V7.4.8

Documentation / Wiki

Manual

Samples

https://www.ibhsoftec.com/epages/63444704.suen_utv.uoje vatn-/mopsiros.4 tun/Lateg on ES/ uovvnioaa

Chapter 1 IBH Link IoT setup Page 1-27

TTI Trans Tech International© 2020 IBH Link IoT Training

Click Open to close the File Upload dialog box and click the Upload

Configuration button.

The progress of the upload is

displayed.

A restart is required to complete the configuration transfer.

Firmware Update

The following procedure is necessary to carry out a firmware update:

1. Save the configuration.

The existing configuration must be saved as

described above (click Download).

2. Download the firmware for the IBH Link UA from the

IBHsoftec homepage.

Page 34: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link UA Firmware V5.20 HWI

IBH Link UA Firmware V5.20 HVV2 SC

L System J Device information

Firmware Version IBH Link UA V6.17 Nov 20 2020 13:00:42 Serial number 1077 .40.number of CPU cores

HiPtF revision 2_0«1 imx6 single-core

IBH Link UA Firmware V5.20 HW.2 OC

Browne...

Firmware Update:Select firmware File

Upload Firmware

Browse.,. No file selected.

Blick

Upload Firmv,,are

Firmware file to perform an update. Typically the file name is ibhlinkua-update-vMX-revision-type.tar.

Choose File to Upload

♦ > This PC > Downloads Search Downloads

X

Organize Nebv folder

This PC Name Date modified Type Size

mg Desktop gfw-update-v5_20-sc.tar 05.01.2021 13:05 tar Archive 98.280 KB

Documents fwwpdate-v303.tar vNele,022.04.2017 12:56 tar Archive 42.120 KB

;97 Downloads

v

File name: fw-update-v5_20-sc.tar is inserted v Custom Files (*Aar)

(confirel Open Cancel

Page 1-28 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

There are three firmware versions available for download.

HW1

This firmware version is only intended for IBH Link UA's, not for IBH

Link IoT's.

HW2 SC

This is the firmware version for the IBH Link IoT having the following

HW revision shown in the System browser window:

A number separated by dots (2.0.1 - the last digit indicates the

number of CPU cores) and the addition imx6.

HW2 QC

This firmware version is only intended for IBH Link UA's, currently not

for IBH Link IoT’s.

3. Backup configuration.

Backup the IBH Link IoT configuration as described above.

4. Select the saved firmware file.

Click the Browse button. The File Upload dialog

box opens. Select the firmware file * .tar for uploading.

File Upload dialog box

The firmware file *.tar is displayed.

Page 35: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Firmware Update: Select firmware File Browse...

is inseed

Cw-update-v5_20-sc.trtarj

€11133 Upload Firmware Upload Firmware

Firmware file to perform an update. Typically the file name is ibhlinkua-update-vXXX-revision-type_tar.

After a firmware file to perform an update has been selected, it must be uploaded, before the newfirmware can be applied.

Important information about the firmware download

To update the firmware all communication must be cancelled. This may take a moment

The upload starb then Cancel nm?

coir eiLn Ok Cancel

Firmware Update: Select firmware File 29% Firmware file to perform an update_ Typically

the file name is ibhlinkua-update-vXXX-revision-type_tar.

Important information about the firmware download

Updating the firmware can take up to 2 Minutes. Do not remove Power from the IDH Link UA during that time.

The LEDs show the current update step. After the LEDs return ta normal operation the process has finished.

Update firmware now?

Firmwareupdate in progress.

Progress:

Preparing system for the firmware update

Firmwareupdate in progres

Progress:

Firmware update completed« There will be 3 reboots

100%

tonfirm Ok I Cancel I

Firmwareupdate in progress.

Progress:

The firmware update is active.

This will take approximately 2 Minutes. Please wait

8%

Chapter 1 IBH Link IoT setup Page 1-29

TTI Trans Tech International© 2020 IBH Link IoT Training

5. Click the Upload Firmware button to load the new firmware

into the IBH Link IoT. The new firmware is not yet accepted

(updated). Confirm the message.

The progress of loading the firmware update is displayed.

The loading of the firmware is indicated. If the

loading is completed, the following message is

displayed.

6. Confirm the message.

The firmware update process is indicated. In the upper-right

corner of the browser window Loading appears.

If the LEDs show normal operation, the browser window of the

IBH Link IoT must be reopened and the firmware updates is

completed.

Page 36: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

e " -

IBH Link loT

0 10.0.13.14/?_./backuprestore 0 ei

Network

Security

Certificates

Time settings

System]

Diagnostics mfrre7,9,n

CRestart IBH Link MD

Reboot Reboot I Restarts the device. All communication with PLCs and OPC UA

(ch lif Clients will be interrupted. Click only, if you are absolutely sure.

Logout Update password

rr System 11

rDevice information

Firmware Version IBH Link UA V5.20 Dec 28 202016:39:56 Serial number HW revision MAC address 1 MAC address 2-4 CPU load (%) Memory usage (%) Temperature (°c.)VBAT 5V VIN 24

1077 2_0.1 imx6 single-core 50 : 2D: F4:1D:3C:22 60:2D:F4:1C:21:2A 11.9 23.2 48.3 6.03V 23.92V

In m ® fie E

single-core

rRestarts the device. All communication with PLCs and OPC UA Clients will be interrupted. Click only, if you are absolutely sure.

111 IBH Link UA - Diagnostics

® ->

!MR • NetworkSecurity

Certifi ,

Tim

Diagnostics

NlicroSD

X ❑ X

D P 10.0.13.14/?_=/diaglistview *

Logout Update password

CNetwork diagnostics System Log

Diagnostic output

erster Hostname / IP Address: 192.168.1.15 Send Ping I Resolve hostname

Select or type Trace filier

Download Trace I Delete Trace

+ CD (a)

single-core

dick Send a ping to a host to test DNS and network connectivity

Page 1-30 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

In normal operation, the RUN LED is lit, the

SYS LED flashes, and the LED's Status

and Error are off.

1.10.3 Restart the IBH Link IoT

By clicking the Reboot button, the IBH Link IoT software is

restarted.

1.11 Diagnosis Browser window

The browser window Diagnosis has two tabs to display details about

established or faulty connections.

Network diagnostics

An ICMP ping is sent to the specified IP address (host name) by

clicking the Send ping button.

Page 37: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link UA- Diagnostics X

0 Pi 10.0.13.14/?_=/diaglistview ± III\ 0 (ID ii

MI. Network

Security

Certificates

Time settings

System

Diagnostic]

MicroSD

Logout I update password

Network diagnostics System Log

Diagnostic output

ping 192.168.1.15 - 192.168.1.15: [0], 84 bytes, 0.59 ms (0.59 avg, 0% loss) ot 192.168.1.15: (11, 84 bytes, 0.50 ms (0.54 avg, 0% lose) Ys 192.168.1.15: [2], 84 bytes, 0.52 ms (0.53 avg, 0% lose)

192.168.1.15 : mt/ro//%1oss 3/3/0%, min/avg/max 0.50/0.53/0.59••

single-core

Hostname / IP Address: 192.168.1.15

Select or type Trace fiker

Download Trace 1 Delete Trace 1

11111111lillsoftec wvvvv ibhsoftec com Contact Wiki

1

Send Plag 1 Resolve hostname 1

dick Start trace Stop trace

01 IBH Link loT embeellded Twenviewer Oatevav

r..+1 TeamViewer 16.41 Internet of Tfongs

95 IBH Link UA - Diagnostics X 0 X

® 0 /I' 10.0.13.14/?_=/diaglistview ler In ® E

-41 I * Logout 11 Update password single-core

S

Diagnosticsj

MicroSD

g->

rhietwork diagnostics 1 System Log

Diagnostic output

nslookup 192.168.1.15 «. Server: 192.168.178.1

Address 1: 192.168.178.1 fritz.box

o Name: 192.168.1.15 Address 1: 192.168.1.15

Hostname / IP Address: 192.168.1.15

Select or type Trace filier ••••

Download Trace 1 Delete Trace 1

11111111131Isoftec wwwibhsoflec.com Contact Wiki

Send Ping 1 Resolve hosiname

Start lrace Stop trace

IBH Link loT errebakled Tennenewer Gateway

TeamViewer 16...4 Internet of Things

IBH Link UA - Diagnostics X El X

Dr ei 10.0.13.141?_=fdiaglistview * 4, m 4

Network

Security

Certificates

Time settings

System

Diagnostics?

MicroSD

ut Update password

System Log

Diagnostic output

Hostname / IP Address: 192.168.1.15

i ethl host 192.168.1.14

Select or type Trace teer

-i eth0 -s0 -I port 48010

i ethl -s0 -I port 102

ethl -s0 -I port 502

ethl host 192.168.1.14

111111111311softec www.ibhsoftec.corn Contact Wiki

i ethl host 192.168.1.14

.1= 0

single-care

Send Ping 1 Resolve bösimme

'Start trace 1 S' top irace

dick Starts the network trace

Enter tcpdump trace filter for detailled logging

IBH Link IoT embedded Teamvier...er Gateway

TeamViewer 1 .4 Internet of Things

Chapter 1 IBH Link IoT setup Page 1-31

TTI Trans Tech International© 2020 IBH Link IoT Training

Resolve Hostname

Is the Wireshark diagnostic software installed on the

PC, a very extensive network analysis can be

carried out?

Page 38: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

i1 IBH Link UA - Diagnostics X ❑

—> C 13 i 10.0.13.14/7_=/diaglistview 4, In lD ® E

Network

Security

Certificates

Logout Update password

Network diagnostics

Diagnostic output

tcpdump pid: 9779

tcpdump exited with status

Time settings Hestname / IP Address:

System

Diagnostics

MicroSID

System Log

192.168.1.15

ethl holt 192.168.1.14

single-core

Send ging I Resolve hos1rarre1

-I ethl kost 192.168.1.14

rStoptraxe-tekra-91/,, Stops the network tracee

Download Trete 1 Erdete Trace

4 ick

Elownload Trace for InspectIon with VV1r.mhark

111111111311softec www_lbhseflec_com Contact Wie

Opening 18HLInklIA-Trace.pcap

You have chosen to open:

El IBHLinkUA-Trace.prAp

whIch is: pcap File

from: http://192.168.1.14

WIlat shoukl Firefox da with thk fite?

0 Open with [Wireshark (Standard)

0 ave File

5 cbck

9 c‘u Ple idt Search Meer incoOng Language SettIngs Tools Macro Run Plugins Winclow

• 0 • • '4 o eeeeLeLec,n.qo

OK Cencel

fere Ionrce 0.1nelon Protocol

42816.195278 192.168.1.10 192.168.1.14 HTTP

42916.267644 192.168.1.10 HUP

43016.249276 192.168.1.10 192.168.1.14 TCP

43116.389515 S7C11111

43215.394255 192.168.1.16 192.168.1.14 S7C11111

433 16.364350 TCP

434 16.484419 192.160.1.10 S7C11111

435 16.405263 192.168.1.14 57C111.1

436 16.405396 192.166.1.10 TCP

437 16.546137 192.168.1.12 57C111.1

438 16.573524 192.168.1.14 S7C01.1

439 16.573676 TCP

. 1: byte, 8. , 00 Mrtes 09702 N (480 bitt)

Start trace

1BH Link loT TeamViewer Itenneta6[01,

O ein Elio

1039 POST rhltd-30119x0r9BnoTO. HTTP/1.1 (application', -wo. -form euriencoded)

3519RP/1.1 20000 (text/jay. ,,. -iPt) 60 51540 . BO [KK] seg-51672 00k-50930 min-1023 Len,'

05 ROSCTR:plo6 ] runction4Read Var]

BI RO5CTR:[Ack_Oata] runction4Read Var]

54 39114 . 102 [KK] 509-520 Ack -460 Min-29200 Len,'

135 ROSCTR4006 ] runction4write Var]

70 RO5CTR:[Ack_Oata] Function4write Var]

54 34664 . 102 [KK] seg-1370 Ade-409 Min-457 Len,'

05 ROSCTR4006 ] Function:pread Var]

87 RO5CTIO[AckOata] runctior9[Read Var] 52320

54 . 102 [KK] 5,-1055 Ack-1123 900729200 Lenk

Ethernet II, Src: 5iemer9_13:23:c6 (00:16:19013:23:02), Ost: Phyter6e_15:a8:07 (50:2d:f4:15:a8:07)

Internet Protocol Version 4, Src: 192.168.1.29, Ost: 192.168.1.14

g TranallinniOn Central. Prertarra, 570 Peri: 09153, Ont Port: 102, 5e9: 1, Ack: 1, Len: 0

Mareie 502d 4415 a6 07 00 16 16 13 23 c6 OB 00 45 00

0010 00 26 Oa 66 00 00 le 06 Oe 9d c0 a6 1 1d c0 a6

0010 01 Oe c0 01 00 66 00 03 Ela 86 6c 5c 29 fa 50 10

0030 10 00 66 11 00 00 00 00 EM 00 00 00

• 7 If1-.1,111A-Tra,22-4.,, HProll:Default

Page 1-32 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Download recording for evaluation with Wireshark

By clicking on Download Trace and confirming the opening with

Wireshark, the Wireshark window - Trace is opened or can be saved

in a file. Since the evaluation of Wireshark-Trace requires some

specialist knowledge, this diagnosis should be carried out in the

event of a malfunction using the IBHsoftec hotline.

System logs

The IBH Link IoT diagnosis creates a log file in which IBH Link IoT

activities are recorded with a time stamp.

Buttons are provided to display the log file in an editor or to save it as

a text file or to delete it. In the event of a malfunction, an analysis can

be carried out using the IBHsoftec hotline.

Page 39: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

III ICH Link LIA Diagnostics X + -

® e

Network

Security

Certificates

Time settings

System

Diagnostics

MicroSD

io 0 13 14figg/diaglistview

Logou Update pasrord

Network diagnos

Logged Events

System Log I

± III\ CD 9 : 0 E

• 10. 3.2020 17:19:34 : Status Clx0 : System'. IBH Link 1JA stopped

15. 3.2020 17:19:48 : Status Clx0 : System'. IBH Link LIA started

15. 3.2020 17:20: 7 : Status Clx0 : Modbus : Modbos COnfiguration deleted

15. 3.2020 17:20: 7: Status 090: System'. IBH Link LIA stopped

15. 3.2020 17:20:10: Status 010: System : IBH Link UA started

15. 3.2020 17:22: Li : Status 010: OPC Client: Client configuration for opc.tcp:

15. 3.2020 17:22: 0 : Status 010: System : IBH link UA sbopped

15. 3.2020 17:22: 4 : Status 010: System : IBH Link UA started

15. 3.2020 17:22:39: Status 010: OPC Client: Client configuration for opc.tcp

15. 3.2020 17:22:39: Status 010: System , !BH Link UA stopped

15. 3.2020 17:22:52 : Status 010: System'. IBH Link UA started

• 15. 3.2020 17:25:33 : Status 010: System'. IBH Link :JA stopped

öownload log% I Clear systern log

111111111311softec wsti.iibhsoftec com Contact Wiki

MicroSD Card Slot

• 113H,Link loT 8 teer '

is

Important information ahout the SD Card formst

• The SD Card will be completely deleted I Format SD Card now7

• IN IBH Link 'JA Microgn

04 e tä

Network

Security

Certificates

Time settings

System

Diagnostics

MicroSD

(ecefirm )11M7371( Cancel

-

Forrnatting done.

Formatling done.

(confirm

0 10.0.13.14/7_ , /optsofMare HK CD 9 X 0 E

Logou Update passworcl

SD Card ormat ard

FOrrnat SD Cord not inseried' Activale Docker

IIIIIIIIDHsoftec wie/ WLsoflee com Contact Wiki

inaerl miero SO um and click

Deactivate Docker

1131-1,LinkloT

3 Teanwiewer iagnetging.,

1/2 11*-Ord

Chapter 1 IBH Link IoT setup Page 1-33

TTI Trans Tech International© 2020 IBH Link IoT Training

1.12 MicroSD browser window

The IBH Link IoT has a slot for a MicroSD card on

the back.

Information on formatting is displayed and must be confirmed.

Note:

The use of the MicroSD card is intended

for future firmware upgrades and

currently has no function.

Page 40: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IR 113H Link 94- MicruSD

O4

31 Network

Security

Certificates

Time settings

System

Diagnostics

MicroSD

X —

10.0.13.14/7_,/opteoftware

Logout Update passtvord

r SD Card

Format SD Card

Format GO Card

The SDCard is mounted. Filesystem: ext4

Disk idevimmcblk0: 7.4 Gift 7909408768 Bytes, 15448064 sectors Units: sectors of 1 *512=512 hytes Seetor size (logmalfphystal) 512 bytes / 512 bytes

I/O size (minimerniciptimel). 512 bytes / 512 bytes Disklabel type: dos

Disk identdier. 0x000951cb

Devise Boot Start End Sectors Size Icl Type /dsvfmmchlk0p1 2048 15448063 15446016 7.4G 83 Linux

Filesystem Type Size Used Availahle Use% Mounted an

/devfmmcblkOp1 ext4 7.2G 16.6h4 6.83 0% imrdisdeard

Activate Docker Deactivate Docker

111111111lilsoftec \Atari ihhsoftec.corn Contact Wiki

BH T Link lo

c TeamVievver Weinet of Things

Reset butten

axv

1 :1

-

tee

;;;K•Lt.1.r -101

Page 1-34 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

The formatted SD card will be mounted automatically.

1.13 IBH Link IoT default factory configuration

The button to reset the software to the default factory configuration is

located on the printed side of the IBH Link IoT, behind the middle

ventilation slot above the printing.

The reset procedure reset the IBH Link IoT is to the default factory

configuration with the current firmware loaded into the device.

Procedure:

• Power down the IBH Link IoT

• Press and hold the reset button

• Power up the IBH Link IoT

• Wait until all four LEDs turn red and go off

again

• Release the reset button

Note:

With a formatted SD card is in the IBH Link IoT, the currently

available IBH Link IoT configuration is saved on the SD card.

If the software is reset to the factory settings with the reset button,

the configuration saved on the SD card is transferred to the IBH Link

IoT at the end of the procedure.

Page 41: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link UA - Network X

( —>

te Network

Security

Certificat,

T

D

di 10.0.13.14/?_=/network • •

Logout Update password

IH\ CD A Ze 0 E

Management Level 1 i Control Level 3 02.1X 1 r TeamViewer IoT

Network Configuration

Endpoint URL or DHCP

IP address

Subnet mask

opc.tcp://ibhlink-ict 4,z,n 1 n 48010

opc.tcp://192.168 17, 1,1 4,1 11 1 1 ,011 1

192.168.178.14

255.255.255.0

r Glob31 System Configuration

1Hostnarne

Furt

Default gateway

Nameserver 1

Nameserver 2

Apply 1 Revert

111111111111softec www.ibhsoftec.com Contact Wiki

AM_ 410CIICK --f ittps://wiki.ibbsoftec.comien/Main_Page*IBH_Link_IJA

" 18Hsoftec Wiki English

ibhlink-iot

48U1U

192.168.178.1

192.168.178.1

10.0.13.1

https://eviki.ibhsofteccom/enNaini

IBH Link loT

I IPL

• Startup operations

• Manual

• TeamViewer loT License IBH Link loT

• TeamViewer loT License IBH Link LM

IBH Link loT embeckled Teamvierer Getewav

TeamViewer 151,nel 0` Ilnnq:

ti

Chapter 1 IBH Link IoT setup Page 1-35

TTI Trans Tech International© 2020 IBH Link IoT Training

1.14 Open the Wiki

IBHsoftec GmbH maintains a WIKI site on the Internet. An extra

section for the IBH Link IoT is provided. Here the use of the

IBH Link IoTA is described in detail.

If your PC is connected to the Internet, the WIKI page can be directly

called from the IBH Link IoT.

Open WIKI website

Page 42: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Page 1-36 IBH Link IoT setup Chapter 1

IBH Link IoT Training TTI Trans Tech International© 2020

Page 43: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

S5+♦1

Offligin FILM!

Ethernet laue

ä PLC 1500

S7++1

inemet bus

nie et bu

S7-CPU-1

IBH Link loT

Switch

I bus

57+

Management Level

ontro Le el

CPU 312 CPU 416-1

CPU 416-2

Ethernet bus

External PC

Access to the Control Level with

TeamVlewer loT via the Internet

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-1

TTI Trans Tech International© 2020 IBH Link IoT Training

2 Access to controls (devices) connected to the ports of the control level

The example demonstrates the possible to display the online status

of CPUs connected to the Control level of an IBH Link UA.

2.1 Remote IBH Link UA with connected CPUs

Several PLC programming systems for online access to the

individual controls are installed on the external PC.

PLC control IP address Control levelProgramming

system

CPU 416 S7e 10.0.13.11 STEP 7 Simatic ManagerCPU 312 S7e IoT S7++1 / 10.0.13.25

PLC 1500 TIA16e 10.0.13.90

TIA Portal V16PLC 1200 TIA16e 10.0.13.91

CPU 312 TIA16e IoT S7++2 / 10.0.13.26

CPU 416 TIA16e 10.0.13.9

S5 CPU 103Ue IoT S5++1 / 10.0.13.27 S5 for Windows

IBH Link IoTControl Level 10.0.13.14

Management Level DHCP

The Management Level port has direct access to the Internet.

The IBH Link UA TeamViewer IoT function has been activated on

the remote IBH Link UA as described in chapter 1.5.

2.1.1 Local PC

Several PLC programming software are installed on the local PC to

display the online status of the CPUs.

Page 44: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Te•irriVIe gfer

IBH Link loT., "IirKc7),

Close TeamViewer connection...

Agent,.

Help...

Homepage,,

Informaton..

Close IBHNet-loT Tray

rieht dick

ibhlinkua_qc TeamViewer O

UI File transfer Remote AppControl r r Ar -Air

Login

The password is case-sensitive.

User narre Enter your user narre

Password Enter your password

Remember rne Keeps log in for 2 weeks 1-1

Lagin

Lost password

1111111iiisoftec snvw.ibhsoftec.com Contact Wild

single-core

ISHNet-loTTray - IBIlsoftec GmbH Peack.

16:30 1) 2020-09-03 E: 1

C onnection establishment x

Progress [

Configuration complete

- Connected agent

Remote=ibblinkua_sc Address=10.0.13.89 Mask=255.255.255.0

istening non: 31711 allowed ipsi 192.168.179.0/24 Cancel

IBH Link UA embeddad OPC VA sener f client

ffl P UAA

Page 2-2 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

TeamViewer is installed on the local PC. There is access to a

TeamViewer account with the corresponding IoT license. The

IBHsoftec software IBHNet-IoT-Setup.exe is installed. The

TeamViewer ID of the Remote IBH Link UA and its name has been

inserted into the TeamViewer Shortcuts dialog box via the Agents…

command from the IBHNet-IoT Tray context menu.

• Start the TeamViewer software.

• Right click on the IBHNet-IoT

Tray icon to open the context

menu.

• With a click on IBH Link UA

SC, the connection to the

ibhlink-iot address is

established via the Internet.

The establishment of the connection is displayed and the Port

Forwarding of the Remote AppControl are displayed.

• Start the programming software (STEP 7, TIA, S5 for Windows etc.).

The examples show connections from the CPU to the control level of

an IBH Link IoT via an IBH Link S7++ or IBH Link S5++. It is

possible to check the connections and the settings of the IBH links.

Note:

To access the individual CPUs (devices) (e.g. status) no registration to

the IBH Link IoT is necessary.

Page 45: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBHNet-IoTTray - IBHsoftec GmbH Sent1lD604 Received:1D433

lana BHNrt

1 IBH Network settings X

File Stations IBH Links Options Help Station:

Station Name Address

loT S5++1 10.0.13.27:102

loT 57++2 PLC 416-VM1 PLC 416-VM2

Settings: —

10.0.13.26 10.0.13.11 10.0.13.9

mark

Lists the access names available an this PC. Doubleclick opens the properties.

Search and configure IBH Link S7, Plus, S7++ and S7++ HS devices.

New station dick

ange s a Ion ee esa Ion

IBH Link S7 IBH Link S5 I IBH Link 55++ Language

Close Version: 1.67 Help

1 Multiple Network Cards detected X

— Please choose the Network Card for the IBH Link search

Description 1 IP address 1 MAC address 1 Address 1 Intel(R ) Ethernet Connection (2)1219-V 192.168.178.10 30.5A-3A-57-2E-1C DHCP WireGuard Tunnel

mark)192.168.179.1 00.00.00.00.00.00 Static

Multiple Network Cards were detected in your PC. Please choose the Network card for the IBH Links search.

d confirm)

❑K I Cancel I Help I

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-3

TTI Trans Tech International© 2020 IBH Link IoT Training

2.1.2 Check IBH Link S7++ settings

CPUs of the S7-300 and S7-400 series not having a free Ethernet

interface can be connected to the IBH Link IoT via MPI bus via an

IBH Link S7++ via Ethernet (RFC 1006 protocol).

The IBH Link S7++ is an Ethernet converter. The protocol used is

standard TCP / IP. The user can benefit from all the advantages of

Ethernet without any problems.

If the connection to the IBH Link

IoT is established via the

Internet, the IBHNet-IoT tray

symbol has a green corner at the

bottom left, and transmission

data is displayed.

After starting Manage IBHNet Stations, the

IBH Network Settings dialog box opens.

Click the IBH Link S7 button to open the

Detect multiple network cards dialog box.

Dialog box IBH Network Settings

Mark WireGuard Tunnel and confirm with OK.

Page 46: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Multiple Network Cards detected

— Please choose the Network Card for the IBH Link search

Description IP address . - ..e• er 172.11154.1

1Wintun Userspace Tunnel 192.15:3.178.1 ne • 17 • A-"' • • I Hz 192.168.43.141)

Microsoft Wi-Fi Direct Virtual Adapter 115 0.0.0. Microsoft Wi-Fi Direct Virtual Adapter 146 0.0.0.C1

Multiple Network Cards were detected in your PC. Please choose the Network card for the IBH Links search.

IBHLinIs in the Iccal netyverk

Found IBHLinks.

MAC Address Serial N umher IR Address Station name

1 MAC address l Address 00-15-5D-BB-18-... Static HIHI: Hin-00 Static 78-213-46-813-F5-... DHCP 78-2B -46-BB-F5-... DHCP 7A-2B-46-BB-F5-... DHCP

OK I Cancel I Help

Search IP address range X

—Address range

Start Count:

1 150.1125 IP-Address

IBH Link (cfick 1 bebente

romfirm OK Cancel

E Configuration via Router 0.0.0.0

(dick

OK S 8 Search again h IP range Help I

Firmware

IBHLinks in the local network

—Found IBHLinks:

MAC Address TYP. j Serial Number 1 IP Address 1 Station name 00.02...42.21.56.GB r1L513MF1 25208 10.0.13.25 loT 57..1

is inserted

r Configuration via Router

ick)

OK Settings I Search again

Firmware V2.168

0.0.0.0

Search IR range I Help I

Page 2-4 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

In the IBH Links in the local network dialog box, click the Search

IP range button.

Searching for several IBH links is impossible over the Internet. In the

Search IP Range dialog box, enter the IP address of the

IBH Link S7++ to be searched and the number 1. When you click

OK, the connection to the IBH Link S7++ is established.

Information of the connected IBH Link S7++ are displayed.

Note!

Windows use two names for network adapters, the Name given by the

Hardware or the FriendlyName.

o WireGuard Tunnel

o Wintun Userspace Tunnel

Depending on the software using network adapter and the Windows status

the Hardware Name or the FriendlyName is displayed.

Page 47: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

181-1Link settings - 00025208 MAC: 00-02-A2-21-56-C8 X

Network MPI/Profibus 1 Time synchronisation 1 firmware 1 21 iagnosti

—Address settings:

Network name: S7++ 1 IP-Address

10 . 0 . 13 25 IBH Link S74-.

IP-Address: r Static

Subnet mask: 255 . 255 . 255 . 0 DHCP Boot-P

Gateway: 0 . 0 . 0 . 0

r IBHNet port (Port 1099 is always active): IV

Authentification

Username:

Password:

ladmin

Change password

— Options — r Configuration with NetPro/TIA

r DisableWeDserver

Save permanently Reboot 1 Cancel

18HLink settings - 00025208 MAC: 00-02-A2-21-56-C8 X

MPI/Profilms 1 Time synchronisation 1 firmware

(clickiNetwork statuJ'Diag

Diagno tics 1 Station

Jesting will attempt to establish a network connection to the IBH Link and read the current settings.

Test 1 1Lifelist OK

Station address: 10

Bus parameters: Baudrate: 187.5 kBit/s Tslot_Int: 415 Max. Tsdr: 400 Min. Tsdr: 20 Tset: 12 Tru n

— Bus Nodes

MPI-Address CPU 312

Fixed bus parameter settings C Automatic detection

MPI-Address IBM Link 374-.

A

0 ' 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 orr rrrrrrrirrrrrrrrrmrr rrrrrrr rrrrrrrrr grrrrrrrrrrrrrrrrrrrr wrrrrrrrrrrrrrrrrrrrr Elorrrrrrrrrrrrrrrrrrrr loorrrrrrrrrrrrrrrrrrrr uorrrrrrr Key

r Station passive

IBH Network settings El X

File Stations IBH Links Options Help — Station: Language

Station Name Diagnostics

MEMBMBBM NZZ loT S7++1 loT S7++ 2 PLC 416.VM1 PLC 416A/M2

Settings:

New station

IBH Link S7

Close

I Test and Settings *eiU:U .

Test and Setup X

— Test functions

Set PG/PC interface

Diagnostics

— Selected stations for STEP.7

MPI (open 1 select

loT PLC 416 loT S7++ 1 loT 57++2 PLC 416-VM1 PLC 416-VM2

Profibus

Accept

Read

dick.

Station active NI Station active ready

A lifelist of all connected nodes an the bus will be read

I Reboot 1 Cancel

If the IBHNet station can't be chosen over Set PG/PC Interface, li ke it is in the 11A, or due to lack ing user rights, the IBHNet station can be chosen in this dialog.

confirm Cancel

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-5

TTI Trans Tech International© 2020 IBH Link IoT Training

Click on the button Settings to display several tabs with information

on the connected IBH Link S7++.

2.1.3 Two or more IBH Link S7++ in one Subnet

The TIA Portal programming environment does not have a dialog to

select different IBH Link S7++. The selection must be performed

using the IBH Network Settings dialog box.

By clicking the Accept button, the IBHNet driver is given the IP

address. The TIA Portal, therefore, only has access to the assigned

CPU via the IBH Link S7++.

Page 48: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBHNet-loT Tray - IBHsoftec GmbH

Sent:15140 Re( eived:11657

I e'trii te KAekgl(

ri IBH Network settings

File Stations IBH Links Options Help Station:

Station Name Address

loT S7++1 loT S7++2 PLC 416N1,11 PLC 416N1,12

Settings: [

New station

10.0.13.25 10.0.13.26 10.0.13.11 10.0.13.9

Search and configure IBH Link S5++ devices from 2009 or neuer.

?dick station 1 Delete station

dick

Lists the access names available an this PC. Doubleclick opens the properties.

IBH Link S7 I IBH Link S5 I IBH Link S5++

Close Version: 1.67

Language

Help I

Multiple Network Ca rds detected X

Please choose the Network Card for the 16 H Link search

D escription

Intel(R ) Ethernet Connection (2) 1219-V

mark)

IP address MAC address

192.16E1.178.10 30-5A-3A-57-2E-1C

Multiple Network Cards Veele detected in your PC. Please choose the Network card for the IBH Links search.

• • • • • •

dick

OK Cancel Help

Address

DHCP

Page 2-6 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

2.1.4 Check IBH Link S5 ++ settings

CPUs of the S5 series not having a free Ethernet port can be

connected to the IBH Link IoT via the PG interface via an

IBH Link S5++ via Ethernet (RFC 1006 protocol).

The IBH Link S5++ is an Ethernet converter. The protocol used is

standard TCP / IP. The user can benefit from all the advantages of

Ethernet.

If the connection to the IBH Link IoT

is established via the Internet, the

IBHNet-IoT tray symbol has a green

corner at the bottom left, and

transmission data is displayed.

After starting IBHNet Manage Stations, the

IBH Network Settings dialog box opens. Click the

IBH Link S5++ button to open the Detect multiple

network cards dialog box.

Mark WireGuard Tunnel and confirm with OK.

Page 49: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

I 181-1 Link 55++ in the local network

Found IBM Link S5++

MAC Address Type Serial number IP Address Station name

Search IP addre. range

Address range

Start Count:

1 192.168.1.13 IP-Addre es

1811 Link S5++

tonfirm

D Configuration via Router

OK Settings

181-1Link S5++ in the local network

Found IBM Link 55++

MAC Address Type Serial number IP Address Station name

is inserted merk)

(enter)

clmkIsMect

OK r--Cancel

Search again

(dick

Firmware

Search P range ljelp

❑Confi guration via Router

OK

dick

Settings Search again Search IP range ljelp

Firmware

181-1 Link S5:. settings

Firmware:

Inside 1611 Link 55++:

Available for Download:

IP-Address settings:

X

I .64-Release

configfs-eth20-1.64-Release.tar.bz2

Download Firmware

IP-Address

Devicename: 55-103U 1136 Link S5,-4-

IP-Address: 10 0 13 : 27 ® Static

Subnet mask: 255 . 255 . 255 . 0 DHCP

Gateway: 192 . 168 . 1 . 1

Ports:

PU-Port: 10010

FetchiWrite TCP: 2002

RFC1006: 102

Save permanently

DeFault

Reboot Cancel

elChapter 2 Access to controls (devices) connected to the ports of the control

levPage 2-7

TTI Trans Tech International© 2020 IBH Link IoT Training

In the IBH Link S5++ in the local network dialog box, click the

Search IP range button.

Searching for several

IBH links is

impossible over the

Internet. In the

Search IP address

range dialog box,

enter the IP address

of the

IBH Link S5++ to be searched and the number 1.

When you click OK, the connection to the IBH Link S5++ is

established.

Information of the connected IBH Link S5++ are displayed.

Click on the button

Settings to

display information

on the connected

IBH Link S5++.

Note!

Windows use two names for network adapters, the Name given by the

Hardware or the FriendlyName.

o WireGuard Tunnel

o Wintun Userspace Tunnel

Depending on the software using network adapter and the Windows status

the Hardware Name or the FriendlyName is displayed.

Page 50: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

edt SIMATIC Manager - [CPU 416 S7e -- JoT-en \CPU 416 S7e]

BI File Edit Insert PLC View Options

2 CPU 416 S7e ä... igr es re, CPU 416

2 a CPU 416-3 PN/DP 2. g Counter

Source e Blocks

Press F1 to qet Help.

Window Help

Customize...

Access Protection

t. S7-Web2Pl.0

ie_t PG/PC Interface...

dick

Set PG/PC Interface

CAccess Path) LLDP / DCP I PNIO Adapter I Info 1 Access Point of the Application:

F INLINE (STEP 7) --> Wintun Userspace Tunnel.TCPIP.Auto.127]

(Standard for STEP 7)

Ctrl +Alt +E

A, X vQ

Interface Parameter Assignment Used:

(Wintun Userspace Tunnel. TCPIP.Auto.1

USB.S7USB.1 Wintun Userspace Tunne1.150.1 Wintun Userspace Tunnel.T CPI P.1 Wintun Userspace Tunnel.TCPIP.Auto.1

Properties... A Diagnostice...

select Copy...

Delete

Parameter assigment for the IE -PG access o your NDIS CPs with TCP/IP Protocol (RFC-1006))

difoonfirm)

OK Cancel Help

A SIMATIC Manager - [CPU 416 S7e -- A: \_loT-en \CPU 416 S7e]

a File Edit Insert PLC View Options Window Help

O

_

D R3 ei* < No Filter > 7.7/

7173) CPU 416 S7e IS System data 0.0131 013100 0-® CPU 416 FC5 0. DB2 Display counter data

H-® CPU 416-3 PN/DP CJ Counter

Source u Blocks

Press F1 to get Help. EWintun Userspace Tunnel.TCPIP.AuI

,Var - [Display counter data -- ©CPU 416 S71CPU 4151CPU 416-3 PN/DP1Counter ONLINE]

Table Edit Insert PLC Variable View Options Window Help

0.1

-12_1 DW-1511A1 xliblel -1-1 2_1( Ri.fi_Ig_1192117.1vil 622 4_11 2"_11.

Address Symbol Display forma'4rStatus valu'‘Moclify value 1 "Counting ON" IMEEI BOOL true true 2 M 2.5 I "Down" BOOL false 3 M 2.6 I "up" 800L true 4 M 2.0 I "Max" 800L false 5 M 2.1 I "Min" 800L false 6 1 MN 12 I "Countervalue" DEC 5574 7 ! M 2.3 ! "Count" 6 BOOL true true

CPU 416 S7ICPU 4161...1Ccunter IhU11 A

6' X

Page 2-8 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

2.1.5 STEP 7 Simatic Manager – CPU 416 S7e

The CPU 416 has an Ethernet port (IP address 10.0.13.11) and is

directly connected to the Control Level of the IBH Link IoT.

Set interface

Status S7 CPU 416

Page 51: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

SIMATIC Manager - [CPU 312 S7e JoT-en \CPU 312 S7e]

e File Edit Insert PLC View Options Window Help

DäntTeti 2 CPU 312 S7e

CPU 312 ö.® CPU 312

Ö„CI CPU 312 S7e Sources

.{e Blocks

Customize...

Access P rote ction

57-Web2PIC

inF I 'G/PC Interface... lie

dick

Set PG/PC Interface X

[Access Path j LLDP J DCP 1 PNIO Adapter l Ido I

Access Point of the Application:

L....70WLINE(STEP 7)

(Standard for STEP 7)

--> lEIHNet.MPI:j

Interface Parameter Assignment U sed:

11EIHNet.MPI.1

H •er-V Virtual Eth apter TC BHNet.MPI.1 EIHNet.PP1.1

selec

IBHNet.PROFIBUS.1

1

User parameter assignment (conyerted))

Lcontirm

v

dick 2

Properties..i

Diagnostics.

Copy...

Delete

OK Cancel

_

Ctrl +Alt+E

6 X

IBH Network (MPI) X

r Station: t open! selec

loT PLC 416

loT S7++ 2 PLC 416-VM1 PLC-416-V tonfirm

OK

4 IBH network settings I Cancel

SIMATIC Manager - [CPU 312 S7e A:1_1oT-en \CPU 312 Siel .11 — =' 1(O Ep File Edit Insert PLC View Options Window Help

D I E? I e ;;I r< No Filter >

0-9 CPU 312 S7e 23 System data 0.061 006100 D-B CPU 312 0. DB2 0. DB5

E IM CPU 312 .4ar CountingDisplay 0I) CPU 312 S7e

Ih) Sources ih' Blocks

Press F1 to get Help.

,Var - [Countin_gDiwlay ©CPU 312 S7e1CPU 3121CPU 3121CPU 312 S7e ONLINE;

raWn Table Edit Insert PLC Variable View Options Window Help

A DIW-1611g xl6blell-,IMYJN_g_le2dTells_l 22 411

mam

f. Address Symbol Display form Status=. eiN Modify value

• JKA 2.5 1 "Down" BOOL false

I IU 2.6 i "UP" BOOL ue

3 M 2.0 I "Max" BOOL alse

4 M 2.1 "Min"

5 i MW 12 1 "Level _1"

6 i CB2.DBW 0 I "CounterVaLies_1".MinValue _1

7 i CB2.DBW 2 1 "CounterVaLies_1".MaxValue _1

8 CB2.DBW 4 i "CounterVaLies V.Value 1

9 CB2.DBX 6.0 1 "CounterVaLies_1".Counting js_on _1 i BOOL : 111 tn.,,.. "

. BOOL fob°

DEC 7928

DEC 100

DEC 10000

DEC 7927

_ d x

CPU 312 S7ICPU 3121...1CPU 312 S7

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-9

TTI Trans Tech International© 2020 IBH Link IoT Training

2.1.6 STEP 7 Simatic Manager –CPU 312 S7e –

The CPU 312 is connected to the control level of the IBH Link IoT via

an LBH Link S7++ (IoT S7++ IP address 10.0.13.25).

Status S7 CPU 312

Page 52: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Devices

"1" PLC 1500 TIA16e

Add nee, device Devices & networks

ve Siemens - loT-en1PLC 1500 TIA16e1PLC 1500 TIA16e

Project Edit View insart Online Options Tools Window Help

3(a Saue Proi, X ,3 = X 0 1±1 4Wb LS ra.

=LM_ Devices

_11 PLC_1500 [CPU 1511-1 Phil

et Device configuration

JOnline 8, diagnostics

double-click)

vif, Siemens - lor-en1PLC 1500 TIA16eIPLC 1500 TIA16e

Project Edit View Insert Online

_21 3 u Save project ,

73. • _, PLC1500TIA16e

1,;, Add new device di, Devices & networks

• Eä, PLC_1500 (CPL 1511-1 PN]

. ,,..t Device ice confieuration

' ( 1.1 Online & diEgnostics doubie_cbck)

I ..1 Program blocks

I Technology Dbjects

I oi External source Files

I PLCtags

I Lif PLC data types

I Watch and forte tables

I % Online backups

re. Traces

/ Eil Device pro, data 2.4 Program info .74 PLC supervisions & alarms

g PLC alarm text lists

› Eil Local modu es

I Ungrouped devices

I j Security settings

I W Cross-device fuictions

,. e Common data

I re Documentatior settings

Goonline ige Go offline

PLC 1500 TIA16e PLC_1500 [CPU 1511-1 PN[

Diagnostics

Functions mark

Online access

Status

Offline

Online access

Type of the PCPC interface: e_PNIIE

Project tree

Devices

0

Options Tools Window

Go online Extended go online... Go offline

• Simulation

Ctrli-K

elick) Ctrl+bi

▪ Online & diagnostics Receive alarrns

PLCI5CIOTIA1

Add new device mark

Devices & networks • PLC_1500 [CPU 1511-1 PN]

_ 0 X

Totally Integrated Automation ?[4!E 2, 1J PORTAL

— ilä X

El Flash LED

(open 1 select

• I PCPC Interface: Wintun Userspace Tunnel 0 3Connection to intefaceisubnet: I Direct at slot '1 X1' • IM

0

Device address: 10.0.13.90

Go online

(open I select

PNilE

Please , e1P1-

PrelE

LLTeleService

Page 2-10 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

2.1.7 TIA Portal V16 – PLC 1500 TIA16e

There are several ways to establish an online connection in the TIA

Portal. The CPU of the opened project must have the same IP

address as the CPU that is connected to the IBH Link IoT / control

level.

The CPU 1500 is connected to the control level of the IBH Link IoT

(IP address 10.0.13.90).

1. Project tree / devices (PLC 1500) /

online & diagnostics.

The same command is available in the

Online menu. A double-click opens the

Online access window. Settings must be

made here.

2. Online / Extended go online...

The command opens the

Go online dialog box. There

are other ways to open the

Go online dialog box. The

required settings are

identical.

Online & diagnostics – Online access window

In the Online Access dialog box, select the settings as follows:

The Type of PG/PC interface must be selected

according to the hardware configuration of the

CPU.

Page 53: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

open select

Wintun Users■ ace Tunnel

F'lease

I ntel (R) Ethernet Co n n n (2 121 9-V

PLCSIM

•Vintun UserspEtce Tunnel

open 1 select Direct at slot '1 X1'

Please select... Direct at zlot '1 :x:1'PWIE

temens - loT-enUIC 1500 TIA16e1PIC 1500 TIA16e

Project Edit View Insert Online Options Tools Window Help

2 3E1 seveproject s X X ± cas, ± LE a 4,f Go online Go offline Liff tri E

Devices

r2.2

1

PLC 1500 TIA16e

Add new device

Devices & networks

PLC_1500 [CPU 1511-1 PN]

gt Device configuration

Y, Online & diacinostics

rin} Program blocks

Gid, Technology objects

la External source files

PLCtags

► rg PLC data types

Watch and forte tables

► 14‚, Online backups

Traces

Device proxy data

51,1 Program info

El. PLC supervisions & alarms

g PLC alarm text lists t Online card data

Local modules

Ungrouped devices

► j Security settings

Cross-device functions

! Common data

1E12 121 •

I% I •

TIA16e ► PLC_1500 [CPU 1511-1 PIA

Diagnostics

Functions

Online access

Status

Online access

Online -

Type of the PG/PC Interface:

PG/PC intedece:

Connection to interfece/subnet:

1 st getewey:

Device eddress:

_ 0 X

Totally Integrated Automation PORTAL

19Wintun Userspace Tunnel

Direct at slot '1 X1'

10.0.13.90

0, Go offline

Siemens - JOT-enliFIC 1500 TIA16e1PLC 1500 TIA16e

Project Edit View Insert Online Options Tools Window

Save project

Project tree

Devices

Name

PLC1500

Go online

Extended go online...

3 Go offline

Simulation

etr1-1-1(

Ctrl+M

ge Stop CPU utr -FZ. II

y, Online & diagnostics Ctrl-FD PLC 1500 TIA1 Eie n Receive alarms ire Add new device

figh Devices & networks

11 Lit PLC_1500 [CPU 1511-1 PN]

DY Device configuration

11. Online & diagnostics

11

111:erice

CPU 1511-1 PN

tonfirm

Go online

mark

GoOrdire Cancel

Flash LED.

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-11

TTI Trans Tech International© 2020 IBH Link IoT Training

Wintum Userspace Tunnel must

be specified as the PG / PC

interface if there is a direct

connection between the CPU and

IBH Link IoT / control level.

The physical location or the name of the Ethernet

connection must be specified at Connection to

interface/subnet.

The online connection to the CPU1500 is established.

Extended go online access – Online access dialog box

Page 54: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Configured access nodes of ..PLC_1500.

Dence I Crevice taue 15191 1 Interl.e Nee 1 Address Subnet

PLC_1500 CPU 151 PNIIE 1001390 PN/lEy1

Flash LED

Online status inforrnaton:

IP protocol

Type of the PG/PC Interface.

PG/PC Interface:

Connection to interlace/subnet:

tst gehewen,

Select tarnet device

Demce

Pl

Show devices with the same addresses

Devicetype I Ireclece type Addr. ITrandreer

Afe Set IP address in the project IP-Address CPU 1511-1 PN

merk IP address: 10 . 0 13 . 90 1

Subnet mask: 255 . 255 . 255 . 0

Use router

unrnark Router address: 0 0 0 0

IP address is set directly stehe device

2999 search

n Display only error [99999999

ßoOnline

(ceen 1 select

PNIIE

Please seien_

PNIIE

ILTeleService (espen 1 [wett

111.Wintun Userspace Tunnel

Please select..

Intel(R) Ethernet Connection (2) 1219-V

PLCSIM

Wintun Userspace Tunnel

(espen 1 Beige

Direct at slot '1 X1'

Please select... Direct at slot '1 :X1' PN/IE_1

(aper 1 select

Show devices with the same addresses

Show devices wich the same addresses Show all compatible devices Show accessible devices

Page 2-12 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

The Go online dialog box opens.

In the Go online dialog box select the following settings:

The Type of PG/PC interface must be selected

according to the hardware configuration of the

CPU.

Wintum Userspace Tunnel must

be specified as the PG / PC

interface if there is a direct

connection between the CPU and

IBH Link IoT / control level.

The physical location or the name of the Ethernet

connection must be specified at Connection to

interface/subnet.

Show device with the same

address must be selected as the

target device.

Deactivate IP address is set

directly on the device.

Note:If the command Show device with the same address is not

available, no connection to the CPU can be established.

In the hardware configuration of the CPU, the option IP address is

set directly at the device must be deactivated.

Page 55: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Go online

Configured access nodes of "PLC_1500"

Device Device type

PLC_1500 CPU 1511-1 PN

1

Slot

1 X1

Type of the PG/PC interface:

PG/PC interface:

Connection to interface/subnet:

1st gateway:

,,get device:

De,ice Devicetype Interfacetype

Interfacetype

PN/IE

Address

10.0.13.90

ifn Wintun Userspace Tunnel

Direct at slot '1 X1'

Online status information:

tron me

Configured access nodes of "PLC_l 500"

Device ,Device type

PLC_1500 CPU 1511-1 PN

iSubnet

PN/IE_1

open 1 select

opel ect

Show devices with the same addresses

Address rget device

Access address -

(click Itart search

D Display only error messages

üoOnline Cancel

Slot ;Interfacetype Address Subnet

1 X1 PN/IE 10.0.13.90 PN/IE_1

Type of the PG/PC interface:

PG/PC interface:

Connection to interface/subnet:

1 st gate,. .4y:

Select target device:

Device

• PNIIE

Ne Wintun Userspace Tunnel

Direct at slot '1 X1'

erö.

e

Show devices with the same addresses

Device type Interface type Address T3rget device

PLC_1500 CPU 1511-1 PN PN/IE T 10.0.13.90 PLC_1500

PN/IE

n Flash LED

Online status information:

0 Scan completed. 1 compatible devices of 1 accessible devices found.

2? Retrieving device information...

Ni Scan and information retrieval completed.

Access address

Start search

n Display only error messages

GoOnline

LC1500 TIA16e ► PLC_1500 [CPU 1511-1 PN] ► Program blocks ► CounterData 10051 X

4) »2 I I EE Keep actualvalues 5napshot litt 134, Copy snapshots to startvalues Ire _ _ cl Ick

CounterData Name Data type Offset I Start value Monit==. eiNCom ment

1 Static

2 • MinNol 500 1 Int E 0.0 1000 100 minimum counter reading (number) 3 — • hiloxNo1500 Int 2.0 10000 8000 maximum counter reading (number) 4 40 • Count1500 Bool 4.0 falle TRUE Counter is counting

5 40 • Counting0N1500 Bool 4.1 falle TRUE Enable counting

6 • CounteNalue1500 Int 6.0 0 6104 Ni.

1 CounterValue

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-13

TTI Trans Tech International© 2020 IBH Link IoT Training

Search – Go online

Clicking the Start search button attempts to establish an online

connection to the CPU.

If the CPU to be connected is found, further data exchange is

enabled with a click on the Go Online button.

The online connection to the CPU1500 is established.

Status CPU 1500 – data block CounterData [DB5]

Page 56: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Pr ject eint New nsen Online Options Tools Wi

J 39 save project • X figl T,1 X 10

Deviees

j PLC 1200 TIA1 re

Ani new clevice

Dences r.networks

‘' n PLC_1200 [CPU 1211C D4D4DC] 2( Deoce renkerayon

Onhne &dernom.

Pr ject Edit View Insert Online Options

J 3E1 G° .ifilne

Oeyices

PLC1goonm9e

NW Ade ne..., clev.

gevices Argnverb

PLC_1200 [CPU 1211C DC,DaDC]

ject Edit Wenn Insert Online Option I olr W ndow heir

Lt 3 Saue Pr.Ject . x k") ± 919 lt r.4 re)* nnffne Ire Go offline ig EN E! x-1 _Ll

Deyices

j PLC 1200 TAlbe

Add nmydevice

ega Deinen &neeyorks

PLC_1200[CUirriCOCIDODC]

gyoeviceconfigundon 0 Online & diagnesdoe,

h 1.0 Rogennblocks TiSrdsoble-rigki

1:4j. Technology objeCts

p. Ekternel saune nies

r [a Ftc.q5

r 1:a PLC date rypes

h SATT! and Ione tables

h gOnline backups

Denes

h Device proxy dna

Ei Program info

PLC supervisions & elerms

PLC alarm textlists

17I Local modales

GI Ungrouped dryner

Security settings

Crosndevice functions

Common data

r lin Documentation senings

i05005

Fundions MB!

Online access

Status

Offline

Tools Windo

Ct

CtrItM

p. ommea dien ostics arkr

ReCene alerm

Totally Integrated Automation

PORTAL

A -351-1. I n Flash LED

Online access

Type of the PGIPC Interface

PGIPCinterfece2

Connectionto interacenubnet:

1 st gateway:

LPNIIE

lairrintun Uienrann Tunnel

Direx at slot '1 X1'

100139

. 11. 10

e

(open 7 select

RWE

Please select._

PNfIE

y_ TeleService

Page 2-14 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

2.1.8 PLC 1200 TIA16d – IP-Address 10.0.13.91

There are several ways to establish an online connection in the TIA

Portal. The CPU of the opened project must have the same IP

address as the CPU that is connected to the IBH Link IoT / control

level.

The CPU 1200 is connected to the control level of the IBH Link IoT

(IP address 10.0.13.91).

1. Project tree / devices (PLC 1200) /

online & diagnostics.

The same command is available in

the Online menu. A double-click

opens the Online access window.

Settings must be made here.

2. Online / Extended go online...

The command opens the Go

online dialog box. There are

other ways to open the Go online

dialog box. The required settings

are identical.

Online & diagnostics – Online access window

In the Online Access dialog box, select the settings as follows:

The Type of PG/PC interface must be selected

according to the hardware configuration of the

CPU.

Page 57: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

open select

123Wintun Users■ ace Tunnel

F'lease

I ntel (R) Ethernet Co n n c: n (2 I2 9-V

#al PLCSIM

•Vintun UserspEtce Tunnel

Dpe e I ect

Direct at slot '1 X1'

Please select... Direct at zlor1 :x:1' PrelE

temens - AIoT-enVIC 1 200 TIA1 6e1FIC 1 200 TIA1 6e

Project Edit View Insert Online Options Tools Window Help

3 8 Save projec.: X ± ± : jki Go online dir Go offline h? __F-] 3 X J _

1

Devices

1E12 PLC 1200 TIA16e

Add new device

Devices & networks

PLC_1200 [CPU 1211C DC/DC/DC]

Device configuration

t V.. Online & diagnostics

Program blocks

E Technology objects

la External source Files

PLCtags

Eg PLC data types

,c; ',Match and forte tables

Online backups

Traces

Device proxy data

kt Program info

PLC supervisions & alarms

g PLC alarm text lists

E Online card data

EI Local modules

Ungrouped devioes

j Security settings

Cross-device functions

! Common data

1121•

PLC 1200 TI PLC_1200 [CPU 1211C D U,I

=IM Diagnostics

Functions

Online access

Status

Online access

_ 0 X

Totally Integrated Automation PORTAL

Online 11 T3

n Flash LED

Type of the PG/PC interface2

PG/PC interface:

Connection to interiace/subnet:

1st gateway:

Device address:

a Siemens - loT-enTLC 1200 TIA160PLC 1200 TIA16e

Project Edit Viev." Insert Online

■ r 3 u Sage project

Project tree

Devices

PLC 1200 TIA1 6e

Add new device

Devices &networks

Lit PLC_121313 [CPU 12110 DC1+DVDC]

py Device configuration

Online & diagnostics

ILPNIIE Wintun Userspace Tunnel

Direct at slot '1 X1'

10.0.13.91

I • y„ Go offline

Options Tools Window

fil Go online

0 40 Go offline

Simulation

Extended go online... Ctrl+K

Ctrl+M

IIII Stop CPU Ctr +Shrft+Q

M Online & diagnostics Ctr1+1)

Receive alarms

Select devices for the online connection

Name

PLC_1 21:10

Interface type Rto online

CPU 1 21 1 C DCIDCIDC mark)

lllll 111

fioOnline Cencel

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-15

TTI Trans Tech International© 2020 IBH Link IoT Training

Wintum Userspace Tunnel must

be specified as the PG / PC

interface if there is a direct

connection between the CPU and

IBH Link IoT / control level.

The physical location or the name of the Ethernet

connection must be specified at Connection to

interface/subnet. This selection is only available

if a network is configurated.

The online connection to the CPU1200 is established.

Extended go online access – Online access dialog box

Page 58: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Configured access nodes of "FLC_1 200"

Device Devicetype Slot Interface type Address Subnet

PLC_1 200 CPU 1211C DCJD... 1 X1 PWIE 10.0.13.91

Type of the PG/PC interface:

Connection to interfaceisubnev

Ist gateway.!

Selecttarget device:

Device

Flash LED

Please select«..

Device type ( Interfacetype

Show devices with the same addresses

Address Targ et device

'.itart

'2 Information: Q Display only error messages

GoOnline

(open select:4411b,..,

Please select.... Pr4i1E

ILTeleSer...ice

(open i select

Wintun Userspace Tunnel

Please select.. Intel(R) Ethernet Connection (2) 1219-V'

PLCSI

Wintun Userspace Tunnel

(open 1 select

Show devices with the same addresses Show devices with the same addresses Show all compatible devices Show accessible de,iices

(.operi 1 select )rifi

1 X1 1

Plezi5e 5elect... Direct et slot '1 X1' FTVIE

Page 2-16 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

The Go online dialog box opens.

In the Go online dialog box select the following settings:

The Type of PG/PC interface must be selected

according to the hardware configuration of the

CPU.

Wintum Userspace Tunnel must

be specified as the PG / PC

interface if there is a direct

connection between the CPU and

IBH Link IoT / control level.

Show device with the same

address must be selected as the

target device.

The physical location or the name of the

Ethernet connection must be specified at

Connection to interface/subnet. This

selection is only available if a network is

configurated.

Note:If the command Show device with the same address is not

available, no connection to the CPU can be established.

In the hardware configuration of the CPU, the option IP address is

set directly at the device must be deactivated.

Page 59: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IP Iprotocol

elp Set IP address in the project IP-Address

CPU 1211Croark IP address: 10 . 0 . 13 . 91 J

&timet mask: 255 . 255 . 255 . 0

Ilse router

unmark Router :Adress: 0 . 0 . 0 . 0

liPitp IP address is set direotly at the device

0 an Ine

Configured access nodes of "PLC_1200"

Device Device type Slot Interfacetype

PLC_1200

Address Subnet

CPU 1211C DC/D... 1X1 PNIIE 10.0.13.91

Type of the PG/PC interface:

PG/PC interface:

Connection to interfaceJsubnet:

1 st gateway:

Wintun Userspace Tunnel

Direct at slot '1 X1'

(open iselect

(open f select),,

Select target device: Show devices wit

Device Devicetype Interface type Address Targetdevice

.1311 llAccess address MIIE

lash LED

Online status information:

0 an Ine

Configured access nodes of "PLC_1200"

Device De.,ce se Slot Interfacetype Address Subnet

PLC_1200 CPU 1211C DGD... 1 X1 PN/IE 10.0.13.91

@lick)1Lätart search

Display only error messages

,00nhne Cancel

Type of the PG/PC interface: ILPNIIE

COnneCtler,

Selecttarget device:

Device

PLC_1200

L Flash LED

Online status information:

0 Scan completed. 1 compatible devices of 1 accessible devices found. 2? Retrieving device information...

Scan and information retrieval completed.

PG/PC interface:

Ist gateway:

Wintun Userspace Tunnel

Direct at slot '1 X1'

Show devices with the same addresses

Device type Interface type (Address

CPU 1211C DGD... PNIIE 10.0.13.91

PNIIE Access address

Target device

PLC_1200

Start search

E Display only error messages

EMD GoOnline Cancel

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-17

TTI Trans Tech International© 2020 IBH Link IoT Training

Deactivate IP address is set directly on the device.

Search – Go online

Clicking the Start search button attempts to establish an online

connection to the CPU.

If the CPU to be connected is found, further data exchange is

enabled with a click on the Go Online button.

The online connection to the CPU1200 is established.

Page 60: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

PLC 1200 TIA1 6e ► PLC_1200 [CPU 1211C DCMCIDC] ► Program blocks ► Counterdato [DB5] —

lig EE Keep actual values

CountorData

la Snepshot «et Copy snapshots ► to startvalues

Start value Name —I Data type Offset flonitor value

1 Static

Com ment

2 -42 . MinNo1200 Int rili 0.0 1000 100 minimurn counter reading (number)

3 -Eil • Maie!, 2IXI Int 2.0 10000 800r1 maximum counter reading {number)

4 el • Count1200 Bool 4.0 TRUE Counter is counting

5 .füi • Counting0N1200 Boo' 4.1 .41111 Enable counting

6 -ell • CounterValuel 200 Int 6.0 0 \2° 4 1111I— CounterValue

IBH Network settings

File Stations IBH Links Options Help

—Station: Language Station Name

loT 55++1 loT 57, -1 loT 57+i- 2 PLC 416-VM1 PLC 416-VM2

—Settings.

New station

Ca:

IBH Link S7 I IBH Link

Close Verei

Diagnostics

Test and Settings 2

Test and Setup X

Test functions

Set PG/PC interface

Diagnostics

Selected stations for STEP.7

MPI i(open 1 seiest

MIME loT S7++ 1

PLC 416-VM1 select PLC 41B-VM2

Profibus

centum

Accept Cancel

Project Edit View Insert Online Options Tools

_1 3 61 Save Project 1, X T.Z. X 9 ±

Devices

CPU 312 TIA16e

Add new device

yr Devices & networks

S7-CPU 300 (CPU 312] )

gy Device configurati,

Program blocks

1

ve, Siemens - ci -en PU 312 TIA16ACPU 312 TIA1 6e

Project Edit View Insen

2 3 13 Save proje,i

Project tree

Devices

• CPU 312 TIA1 6e

fit Add new device Devices & networks

• :I 57-CPU 300 [CPU 312]

Online Options Tools Window

Go online Ctrl+K

E,Tended gc. online...

Go offline d ick) Ctrl+M

111 Simulation

g Online & diegnostics Ctrl+D

n Receive alarrn3

1

Page 2-18 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

Status CPU 1200 – data block CounterData [DB5]

CPU 312 TIA16e– IoT S7++2 – IP address 10.0.13.26

The CPU 312 is

connected to the control

level of the IBH Link IoT

via an IBH Link S7++

(IP address 10.0.13.26).

The IBH Link S7++ (IoT

S7++2 – IP address

10.0.13.26) must be

selected. The project

CPU is addressed via its

MPI address. The

IBHNet driver of the IBH

Link S7++ automatically

assigns the IP address

to the MPI address. The

IBH Link S7++ is connected to the IBH Link IoT / control level.

There are several ways to establish an online connection in the TIA

Portal.

1. Project tree / devices (S7-CPU

300) / online & diagnostics.

The same command is available in

the Online menu. A double-click

opens the Online access window.

Settings must be made here.

2. Online / Extended go

online...

The command opens the Go

online dialog box. There are

other ways to open the Go

online dialog box. The

required settings are identical.

Page 61: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

2{‚, Siemens - JoT-erACPU 312 TIA16ACPU 312 TIA16e _ 0 X

froject Edit yiew Insert Online Options Tools Window delp Totally Integrated Automation r3 61 saveproject . X cü 9. Go online Go offline ft? EM EN X PC

=Mai_Devices Mr

-‘111 _.] CPU 312 TIA16e

gi Add new device

1 Devices & networks

Ell S7-CPU 300 [CPU 312]

e 2,..t Device confieuration ..................

..... J. Online 8 diagnosticjg‹ double-click)

I el Program blocks

I Ei Technology objects

I oi External source files

I PLCtags

, e PLC data types

k i Watch and force tables

I EN Online backups

,. .re Traces

I Erj Device proxy data

lt Program info

PLC supervisions & alarms

k PLC alarm text lists

I EI Local modules

> 1,,, Ungrouped devices

I -1•Ö Security settings

I Wg Cross-device functions

I Eia Common data

E j Documentation settings

CPU 312 TIA16e ► S7-CPU 300 [CPU 312] —

Online access

► Diagnosti

► Functions mark)

Online access

Status

er,

Online access

Flash LED

Dopen / selectWIType of the PG/PC interface: y__ fel

PG/PC interface: I» IBHNet e 3 Connection to interf,,i,ubt,t: Direct at slot '2 X1' ' 0

ist gateway ' 0

LV' Go online

GED

(.Opera s e !ei:1r*

MP'

Please select...

MPI

9— TeleServi e (openi select

IBHNet

Please select... .531, PLCSIM

IBHNet

9?" IEHSoftPLC J

(open ! select

Direct et slot '2 X17,

Please select... Direct ;Bt SlOt '2 . :::1 ' PNIE21

2% Siemens :_loT-erACPU 312 TIA16ACPU 312 TIA16e _ 0 X

Project Edit View Insert Online Options Tools Window Help

3 Save project e X —) ( J n5 y I J Go online £6,9e Go offline Duft

-1-jaMML Devices

_] CPU 312 TIA16e

Add new device

Devices & networks

L S7-CPU 300 [CPU 312]

fit Device configuration

1e Online & diagnostics

Program blocks

Ei Technology objects

la External source files

PLCtags

► 'd PLC data types

► Watch and force tables

Online backups

Device proxy data

Program info

EI PLC supervisions & alarms

k PLC alarm text lists

Local modules

Ungrouped devices

Ungrouped devices

::••ö Security settings

► • Cross-device functions

► • Common data

Documentation settings

1 El 212 •

iagnostics

Functions

e ► 00 [CPU 312

n mark

Online access

Status

Online access

Type of the PG/PC interface:

PG/PC interface:

Connection to interface/subnet:

1st gateway

Device address:

MPI

191BHNet Direct at slot '2 X1'

2

g," Go offline

Totally Integrated Automation PORTAL

LI Flash LED

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-19

TTI Trans Tech International© 2020 IBH Link IoT Training

Online & diagnostics – Online access window

In the Online Access dialog box, select the settings as follows:

The Type of PG/PC interface must be

selected according to the hardware

configuration of the CPU (MPI interface).

IBHNet must be defined as the PG / PC interface

if an IBH Link S7 ++ is used as the connection

between CPU and IBH Link IoT / control level.

The physical location or the name of the Ethernet

connection is only available if a network is

configurated.

The online connection to the CPU312 is established.

Page 62: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Siemens - loT-eniCPU 312 TIA16eICPU 312 TIA16e

Project Edit View Insert Online

Save project

Project tree

Devices

r_e

2 CPU 312 TIA16e

Add new device

Devices & networks

• r_ I 57-CPU 300 [CPU 312]

DY Device configuration

Online & diagnostics

0 2 1 Go offline

2 Simulation

Options Tools Window

Go online

Extended go online...

la Stop CPU

4.! Online & diagnost

Receive alarms

Ctrl+K

cli k I

Go online

,' I:3sh LED

Online status information:

Name

37-CPU 300

Configured access nodes of "37-CPU 300"

Device Device type

S7-CPU 300 CPU 312

Device

Inleracetype

CPU 312

LAJIIHI

MIM

Slot Interface type

2 X1 MPI

1 Type of the PG/PC Interface:

PG/PC interface:

Connection to interfaceisubnet:

1 st gateway:

,,rg et device:

Please select...

GoOriline

Address iSubnet

2

Show devices with tl

Device type I Interface type I Address Target rie.ice

Go online

(mark)

Start

❑ Display only error messages

GoOnline Cancel

MPI

Please select...

MPI

ILTeleService

Cancel

(open ‚' select

Please select... 11. PLCSIM

MIBHSoftPLC

(opent select

Direct at slot '2 X1'

Please select... Direct at slot '2 PNJIE_1

Page 2-20 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

Extended go online access – Online access dialog box

The Go online dialog box opens.

In the Online Access dialog box, select the settings as follows:

The Type of PG/PC interface must be

selected according to the hardware

configuration of the CPU (MPI interface).

IBHNet must be defined as the PG / PC interface if an IBH Link S7++

is used as the connection between CPU and IBH Link IoT / control

level.

The physical location or the name of the Ethernet

connection is only available if a network is

configurated.

The physical location or the name of the Ethernet

connection is only available if a network is

configurated.

Page 63: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

(open i selecf

Show devices with the same addresses device_ with the 5arrie addre55es

Show all compatible devices Show accessible devices

0 an Ine

Configured access nodes of "37-CPU 300"

Device Device type Slot — Interface type I Address

S7-C.PI I Rnn C.F11 :317 9 X1 MPI

Seleo. tuiyet

Device

Online status information:

Go online

Type of the PGIPC interface:

PGIPC interface:

Connecton to interiaceisubnet:

1 .11 gateway:

10_ MPI

IVIIBHNet Directat slot '2 X1'

ISubnet

1::(open / select

eue

(open / aelect)ef.,

31.1uwdeviueb wiLFI lhe warne uLILIrebbeb

Device type Interface type Address

PNIIE Access address

Configured access nodes of "37-CPU 300"

Device

57-CPU 300

Target device

(cluck)Nrk Start search

CilDisplay only error messages

Device type i Slot I Interface type I Address

CFIJ 312 2 X1 MPI 2

Type of the PG/PC interface: MPI

PGIPC interface:

ConnectiDn to interface/subnett

1 st gateway:

Select target device:

Device Device type

Subne:

• 1111IBHNet • Directat slot '2 X1'

Show devices with the same addresses FZI

Interface type I Address

S7-CPU 300 CPU 312 MPI 2

- - MPI Access address

Flash LED

Target device

57-CPU 300

Start search

Online status information: D Display only error mEssages

0 Scan completec. 1 compatible devices of 1 accessible devices found.

rf? Retrieving device information...

rä Scan and information retrieval completed.

click GoOnline Cancel

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-21

TTI Trans Tech International© 2020 IBH Link IoT Training

Show device with the same

address must be selected as the

target device.

Search – Go online

Clicking the Start search button attempts to establish an online

connection to the CPU.

If the CPU to be connected is found, further data exchange is

enabled with a click on the Go Online button.

The online connection to the CPU300 is established.

Page 64: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

CPU 312 TIA16e f S7-CPU 300 [CPU 312] f Program blocks f Counter Data [D02]

e z„

Counter Data

Cre. Keep actualvalues Snapshot Meg. "4. Copy snapshots to startvalues kr _

( Name Data type Offset- 15ton value Monitor value Cornrnent [

1 • Static

2 -3 • Count I Bool

*

F . 0.0 0 TRUE Counter is counting

3 -.3 • CounteiValue Int 2.0 0 4917 CounterValue

4 -U • MinNo Int 4.0 100 100 minimum counter reeding (number)

5 -3 • MaxNo Int 6.0 10000 8000 maximum counter reading (number)

6 -0 • CountingON Bool 8.0 -rake TRUE Enable counting

Project Edit View Insert

Save project

Project tree

Devices

r_e

CPU 416 TIA 1 6e

Add new device

Project Edit View Insert Online Options Tools ve

u Save project X 31 X

Project tree I

Devices

re .

CPU 416 TIA 16e

' Add new device

Devices & networks

CPU 416 [CPU 416-3 PN/DP]

Di Device configuration

Online & diagnostics

.151 Program blocks

Online lOptions Tools Window

Go online CtrI4-K

orExtended go online...

»„Ir Go offline

1E Simulation

clisk

Online 8, diagnostii

p Receive alarrns

11M3

Devices & networks

• • • Lig CPU 416 [CPU 416-3 PN/DP]

double-click

Page 2-22 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

Status CPU 300 – data block Counter Data [DB2]

2.1.9 CPU 416 TIA 16e – (IP-Adresse 10.0.13.9)

There are several ways to establish an online connection in the TIA

Portal. The CPU of the opened project must have the same IP

address as the CPU that is connected to the IBH Link IoT / control

level.

The CPU 416 is connected to the control level of the IBH Link IoT (IP

address 10.0.13.9).

1. Project tree / devices

(CPU 416) / online &

diagnostics.

The same command is

available in the Online

menu. A double-click

opens the Online access

window. Settings must be

made here.

2. Online / Extended go online...

The command opens the Go online dialog box. There are

other ways to open the Go online dialog box. The required

settings are identical.

Page 65: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

lemens - :UoT-erACPU 416 TIA16ACPU 416 TIA 16e

Project Edit View Insert Online Options Tools Window Help

EJ Saue project 3 X E X ± r i ± .5L1 17,4 Goonline ige Go offline d i? Emi Eff

2=1_

•j Devices

2

CPU416TIA16e

Add new device

Devices & networks

_rig CPU 416 [CPU 416-3 PN/DP]

fit Device configuration

Online 8i diagnostics,.....

HI-1 Pro gram blocks

rjg Technology objects

External source Files

PLCtags

L—g] PLC data types

Watch and forte tables

5iry Online backups

rze Traces

Device proxy data

1121 Program info

1 PLC supervisions & alarms

J PLC alarm text lists

Ei Local modules

Ungrouped devices

Security settings

Cross-device functions

Common data

► re nrinnmpntAtinn settings

I

_ 0 X

Totally Integrated Automation PORTAL

CPU 416 TIA 16e 1 CPU 416 [CPU 416-3 PN/DP[ —il X

Diagnostics

Functions mark

Online access

Status

Online access

Offline

Type of the PG/PC interface:

PG/PC interface:

Connection to interfaceisubnet:

1st gateway:

Device address:

0 Flash LED

PNIIE

• Wintun Userspace Tunnel

Direct at slot '2 X5'

10.0.13.9

Go online

dick)

open f seleceki

(open seleet

PNiIE

Please sel

PNiIE

ILTeleService

(open / select

Wintun Userspace Tunnel

Please sei ect....

tel Intel (R) Ethernet Connection (2) 121 9-V

PLCSIM

Wintun Users.pace Tunnel

(open seiect

Direct at slot '2 X5'

Please 3 elect... Direct at slot '-7' Pr'dflE _1

241, Siemens - A:NIoT-en‘CPU 416 TIA16ACPU 416 TIA 16e _ 0 X

Project Edit View Insert Online Options Tools Window Help

Saue Project Ie. X A±el Zei X = h ± ± y Ni Ui

Devices

CPU416TIA16e

Add new device

Devices & networks

CPU 416 [CPU 416-3 PKI/DP]

Device configuration

4. Online 8i diagnosticsi

Program bloch

Technology objects

External source Files

PLC tags

r2A PLC data types

Watch and forte tables

GU Online backups

Traces

rinj, Device proxy data

@I Program info

EI: PLC supervisions & alarms

g PLC alarm text lists

_re. Online card data

Local modules

► Ungrouped devices

gei Security settings

Cross-device functions

Common data

I <I

IU •

51•

Go online ger Go offline

CP ► CPU 416 [CPU 416-3 PNIDP]

TantrzerDiagnostics

Functions

Online access

Status

Online access

Online

Type of the PG/PC interface:

PG/PC interface:

Connection to interface/subnett

1st gateway:

Device address:

Totally Integrated Automation PORTAL

PNIIE

IraWintun Userspace Tunnel

Direct et slot '2 X5'

10.0.13.9

je Go offline

Flash L EIM DI

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-23

TTI Trans Tech International© 2020 IBH Link IoT Training

Online & diagnostics – Online access window

In the Online Access dialog box, select the settings as follows:

The Type of PG/PC interface must be selected

according to the hardware configuration of the CPU.

Wintum Userspace Tunnel must be

specified as the PG / PC interface if

there is a direct connection between the

CPU and IBH Link IoT / control level.

The physical location or the name of the

Ethernet connection must be specified at

Connection to interface/subnet. This selection

is only available if a network is configurated.

The online connection to the CPU 416 is established.

Page 66: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

In I

;,r1,.% Siemens - A IoT-en'CPU 416 TIA16e1CPU 416 TIA 16e

Project Edit View Insert Online

2 1' 61 Save project

Project tree

Devices

ji CPU 416 TIA 1 6e

Add new device

Devices & networks

CPU 416 [CPU 416-3 PN/DP]

111? Device configuration

Y, Online & diagnostics

Options Tools Window

Ar Go online

Extended go online...

Go offline

Simulation

!! Stop CPU

1,1 Online & diagno

Receive alarms

EMD

Flash LED

Online Melos informaton:

Configured access nodes of . 3,101M

Peeme

PP 616

Ctrl+K

Ctrl+M

e ect •evices or opernng t e an ine connection

Name

CPU 416

Deekempe 15b1 ln¢rlsetype lAddress

PP 016-3 PP/CP X1 lel

PP 0163 PP/CP 2X5 PN/le 100139

Type of the PG/P3 Interface:

PG/P3 Interface:

formeeton to mtedace/subnetr

1st gatewayr

Please selecer.

Interface tone 44 Go online

CPU 416-3 PN/DP

confirm

Sehnet

Show devices well the same addresses

Intedecempe Addems arger devde

2tart cearcH

GoOnline

mark

Cancel

(aper 1 seleet

Please select___

PNNE

ILTeleService

(leen 1 select

Wintun Llserspace Tunnel

Please select...

ritel (R) Ethernet Connection (2)1219-V

1111 PLCSIM

Wintun Us.erspace Tunnel

open 1 select

Show devices with the same addresses

Show devices with the 5a rrle addresses Show all compatible devices Show accessible devices

(aper 1 selest

)41111/4. Direct at slot '2 X5'

Please select... Direct at slot '2 X5' PrelE_1

Page 2-24 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

Extended go online access – Online access dialog box

The Go online dialog box opens.

In the Go online dialog box select the following settings:

The Type of PG/PC interface must be selected

according to the hardware configuration of the

CPU.

Wintum Userspace Tunnel must

be specified as the PG / PC

interface if there is a direct

connection between the CPU and

IBH Link IoT / control level.

Show device with the same

address must be selected as the

target device.

The physical location or the name of the

Ethernet connection must be specified at

Connection to interface/subnet. This selection

is only available if a network is configurated.

Page 67: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Configured access nodes of "CPU 41 6"

Device Device type Slot

CPU 41 6 CPU 416-3 PN/DP 2X1

CPU 416-3 PNIDP 2 X5

Type of the PG/PC interface:

PG/PC interface:

Connection to interfacelsubnet:

1 st gateway:

-iect target device:

Device

Online status information:

0 on Ine

Interface type

MPI

PNIIE

__PNIIE

Wintun Userspace Tunnel

Address

2

10.0.13.9

Direct at slot '2 X5*

Subnet

@pell/ aelect

(open/aelect),,

Show devices with the same addresser,

Device type Interfacetype I Address

Configured access nodes of "CPU 416"

Device Device type Slot Interfacetype

CPU 416 CPU 416-3 PN/DP 2 X1 MPI

CPU 416-3 PN/DP 2 X5 PNIIE

Target device

MICE Access addrei lleM

Type of the PG/PC interface:

PG/PC interface:

Connection to interiaceisubnet:

1 st gateway:

(ack).+Itart search

o Display only error messages

B=IEB =EM

Address Subnet

2

10.0.13.9

• lf» Wintun Userspace Tunnel

Direct at slot '2 X5'

Show devices with the same addresses

Device Device type Interface type Address Target device

Accessible device CPU 416-2 DP PN/IE9MF 1 10.0 13.9

— — PNIIE Access address

Flash LED

Online status information:

0 Scan completed. 1 compatible devices of 1 accessible devices found.

2? Retrieving device information...

2 Scan and information retrieval completed.

1

Start search

n Display only error messages

GoOnline Cancel

CPU 416 Tlit 16e h CPU 416 [CPU 416-3 MN] h Program blocks h CounterData [1:1821 OBX

e e gra E Keep saus' values jfa Snapshot är, Copy snapshots to startvalues

Co unterD ata

I

Name •

• MinVelue Int g0.0 100 100 rninirnurn counter value (number) • AlaWalue Int 2.0 10000 10000 maximum countervelue (number)

4 -a • Counting ON Sod 4.0 leise TRUE Counter is counting

5 :3 • CounteeValue Int 6.0 0 4 239 i Counter value

Stati c

Data type Offset Start .1. Monitor value Comrnent

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-25

TTI Trans Tech International© 2020 IBH Link IoT Training

Search – Go online

Clicking the Start search button attempts to establish an online

connection to the CPU.

If the CPU to be connected is found, further data exchange is

enabled with a click on the Go Online button.

The online connection to the CPU416 is established.

Status CPU 416 – data block CounterData [DB2]

Page 68: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IBH Link S5

n S5/57 for Windows° - Counter 55W -- A:\Counter 551.V.S5P

File PLC Find View Window Help

Online

S R FS FR K 63-11 Internal S5 PLC simulation

Internal S7 PLC simulatio Network

loT S5++

PLC 90/95/100 U (CPU 103) Used operands Free operands

1 1...% Program structure p+ i_ Trace back loTCPU416

6.0 loTS7++

6.ga STEP7. PLC 416-VM1

1±1.....v Kommunikationsanschluss (COM1)

v 4 X

-rne.

oTZ1.54-+

IP address:

I 10 . 0 . 13 . 94 )

Timeout.

Milliseconds Default

I131-1 Link 55 I 55 Lan IBH Link 55+j

Attention: This station settings will be changed also within the IBH network settings!

OK .1 Cancel I

PC block list v

Block 001

0 013 21 D 013 22 0 FB 5 D DB 2 D ss 1 <

ATA. Symbol Cycle

!All blocks jtj Marked: 1 total: 6 I Code length marke

Length Last Modification I Description 24 30.07.2020 17:28:27 Cycle 42 30.07.2020 17:50:56 42 30.07.202017:51:12

CounterControl 86 30.07.2020 17:54:24 Counter control CounterValues 16 30.07.2020 15:38:33 CounterValues

110 30.07.2020 17:52:47

Offline Online PC block list PLC block list

PLC 90/95/100 U (CPU 103) IM - INS

rir S5/S7 for Windows® - Counter SSW A:\Counter SSW.S5P o X

File PLC Block Edit InsertCtrkV Presentation Find View Window Help

® e sa. rS1 Clz

S Internal S5 PLC simulation Internal S7 PLC simulation Network

6.9 loT S5++

1±1-1M

DB 2 Status x

61. 11 DB 2

PLC 901951100 U (CPU 103) 0.M Used operands

1 1.-E1 Free operands 1...% Program structure

Trace back loTCPU416 loTS7++

1...13 PLC 416-VM1 STEP7® Communication port(COM1)

Off 1r 7111i Online

4.1 M21 AESR I/ 9.13 = STL CSF LAD

• uY IPI 4in ?

H Title: Counter values

Address

0 1 2

Contents

KF +100 KF +8000 KF +4234

Comment

; minimum numerical value S7 CPU 1 ; maximum numerical value S7 CPU 1 ; numerical value S7 CPU 1

PC block litt O. X

Block 0 os 1 0 OB 21 0 OB 22 0 FB 5

D BB 1

a M LiS Symbol Cycle

CounterControl

( PC block list DPLC block list

All blocks J, 4 Marked: 1 total: 6 I Code length markt

Length Last Modification Description 24 30.07.2020 17:28:27 Cycle 42 30.07.2020 17:50:56 42 30.07.2020 17:51:12 86 30.07.2020 17:54:24 Counter control

110 30.07.2020 17:52:47

PLC 90;95;100 U (CPU 103) CAPS NUM RF INS

Page 2-26 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

S5 for Windows – CPU103-S5++ IoT – IP address 10.0.13.94

Status S5 CPU 103

2.2 Access to a PC - Remote Desktop.

It should be possible to access a PC via an IBH Link IoT, which is

connected to the same subnet as the control level.

To ensure that the connection and the data traffic are secure,

TeamViewer uses end-to-end encryption using RSA public / private

key exchange and 256-bit AES session encryption. In addition, the

IBH Link IoT has a firewall between the management and control

level.

Page 69: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Client

Access to the Control Level with

TeamVIewer loT vla the Internet

Subnot 192.168.1"m

Management Level

Server' Subnet 10.0.13.11F1

control Level

IBH Link UA - Neteork

i&ii3 C e

• raune' Security

Certificates

001

0 ii 10.0.13.141?./nebvork

Time settings

System

Diagnostics

MicroSD

E sotorios

A Hnme

Find a selling

13=1

Display

Renrn IA--)sktop

Logout Update password

TeamView er loT

eamV1ewer Io

TeanNiewerlD

Aeeigne pot Token

Group

TeanNiewer uuto starr

Log level

Croxy Eeving

Proxy eddreee (IP: Pol)

Internet access over proxy 2

nel

TTI

2 Info e

111‘ m ® 0 I

Start Stop New assign Remove assignment Download logfite Delete logfile MQTT settings

— o X

Remote Desktop

Remote Desktop lets you tonnett to and control Ibis PC from a remate device by using a Remote Desktop client (available rar Windows, Android iOS and macOS). You'll be able to work from another device as if you were warking directly an MR PC.

Enable Remote Desktop

42.0)REMOTE CEgik:Cp

C C nig ectic n

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-27

TTI Trans Tech International© 2020 IBH Link IoT Training

Remote desktop refers to the

remote access to the desktop of

a computer. Application

programs are executed on one

computer (server) and displayed

and operated on another

computer (client). In contrast to

screen sharing, no user must

log on locally to the server.

A remote desktop session runs independently of any other session

that may be running.

2.2.1 Preparation of IBH Link IoT and Server (PC)

The management level port of the IBH Link UA has direct access to

the Internet. The TeamViewer IoT Status must be Online.

TeamViewer IoT Status

2.2.2 Local PC (client)

Remote Desktop is activated on the client PC. As an example,

Windows 10 - Settings.

The icon to start the remote desktop connection is

available in the start menu under Windows

accessories.

Page 70: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

IEHNet-loTTray- IBHscftec GmbH Ready

16:30 [—I(i) 2020-09-03

Te r

IBH Link loT dick

Close TeamViewer connection...

Agents...

Help...

Homepage..

Wiki...

Information...

Close IBHNet-loT Tray

)18HNet-loT Tray - IBHsoftec GmbH Ready

1620 .4e. IU el): ' 2020-09-03

Starting Teamviewer X

[Teamviewer start progress

43%

Cancel

Connection establishment

[Progress

Configuration complete

—Connected agent

Lpemote=ibhlink-iot Address=10.0.13.14 Mask=255.255.255.03

istening port: 31711 allowed ips: 192.168.179.0/24 OK Cancel I

Page 2-28 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

• The TeamViewer software is installed on this PC.

• The IBHNet-IoT software

is installed. The service is

displayed in the IBHNet-

IoT Tray in the task bar.

• The name (e.g. IBH Link UA SC) given in the TeamViewer-

Shortcut dialog box is transferred to the TeamViewer

account.

• Start the TeamViewer software with a

double-click.

• Right-click on the IBHNet-IoT Tray icon to open the context

menu. The devices registered with the TeamViewer account

are listed in the upper area of the context menu.

• With a click on IBH Link UA SC, the connection to the

ibhlinkua_sc address is established via the Internet.

The establishment of the connection is displayed.

Page 71: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

ibhlinkua_qc - TeamViewer X

la File transfer

[Ilei •

Login The password is case-sensitive_

Remote AppControl Port Vorward' ,

OPC server is running

User name Enter your user name

Password Enter your password

Remember me Keeps Jogin for 2 weeks 1- 1

Login

Lost password

111111111111softec www.ibbsoftec.com Contact Wiki

7 Remote Desktop Connection

IL Remote Desktop 9n,, Connection

Computer: Example: computerfabrikam.com

User name: None specified

The computer harne field is blank. Enter a full remote computer harne.

Show Qptions Cohnect

gle Remote Desktop Connection X

iL Remote Desktop '..«7›, Connection

(General Display Local Resources Experience Advanced

Logon settings

imt Enterthe name of the remote computer.

Computer: 10.0.1,

enter User narne: PSH

1

You will be asked for crederdials when you connect.

2 ',92n.

Connection settings Save the current connection settings to an RD P file or open a saved connection. 2

Saue I Save As... Open...

3 klick Hide Options Connect Help

quad-co

• IBH Link UA embedded OPC UA server / client

MeIDC UA

Help

teDeitcr c

levelChapter 2 Access to controls (devices) connected to the ports of the control Page 2-29

TTI Trans Tech International© 2020 IBH Link IoT Training

The establishment of the connection is displayed and the Port

Forwarding of the Remote AppControl are displayed.

To access the individual PCs (devices) no registration to the IBH

Link UA is necessary.

Establish remote desktop connection

Double-click the Remote Desktop Connection icon.

In the Remote Desktop Connection dialog box, click

the Show Options button.

Enter the computer (IP address)

and username in the opened

dialog box. These settings can be

saved. Clicking the Connect

button opens the dialog box for

entering the password.

Page 72: IBH Link IoT Sheet 1 - Alles für die S5 und S7 Welt

Windows Securib,r

Enter your credentials

These credenbals will be used to connect to T11-11.

Pein

Center)

TTI-YELLOWete

5 Remember me

Mare choi„,

OK .66

eonnrm

11 Remote Desktop Connedion X

11 The iclentey of the reimte computer campt he wertriech Do NI/ you at 1 orned anneel9

The remote computer Gould not be authenticated due to problems weh ns seantycertficate maybe unsafem proceed

Gerteste name

CQ Name in the certflicate form the rümpfe computer TTIll

Certrreate errom

The following tann were encountered while validating the remote computer% certificate

L1 The out ficate R not from a truCed cetifying authome

Da you warn to connect despitethese certrreate errom?

r , Den, ask me again for connections to Ohio computerj

Nes cartfiente.. ( rett Teh

Cancel

X

Do you wart to connect despfte these certificate errors?

2 hont ask me again for connections to this computer

General Ge Geritem naei

z ig certiReate information

This cx timt eertiReate isnot Trustee To erlabte [net. install this cerhhate n the Trustel lloot Certikalion mthoritesstore.

issved t. -rn-ii

issued he Tnell

valid hon. 2020-0,18 to 2021-0320

...I Cedir.....

si 10.0.133 - gerngedecktopoetrindung +1 .111 ,P X —

fl i

I ...<

Page 2-30 Access to controls (devices) connected to the ports of the control level Chapter 2

IBH Link IoT Training TTI Trans Tech International© 2020

Enter User and Password dialog box

The establishment of the connection is displayed.

Remote computer Certificate verification

If the certificate of the remote computer is not known, a

corresponding message is displayed.

The existing

certificate on the

remote computer

can be viewed.

If the remote computer / certificate is trustworthy, the connection can

be established (click Yes).

The corresponding option must be activated so that there is no

further inquiry when the connection to the PC is established again.

The remote computer's desktop appears. All programs on the PC can

be executed.