20091218112714 j Yee 1 z

download 20091218112714 j Yee 1 z

of 40

Transcript of 20091218112714 j Yee 1 z

  • 8/13/2019 20091218112714 j Yee 1 z

    1/40

    EXCELL PRECISION CO., LTD.

    FB530/FB630

    (Conversion)Dot MatrixPrinter Indicator

    User Manual

    EXCELL PRECISION CO., LTD. 2009. All rights reserved worldwide.

    The information contained herein is the property of EXCELL PRECISION CO., LTD. and is

    supplied without liability for errors or omissions. No part may be reproduced or used except as

    authorized by contract or other written permission. The copyright and the foregoing restriction on

    reproduction and use extend to all media in which the information may be embodied.

  • 8/13/2019 20091218112714 j Yee 1 z

    2/40

  • 8/13/2019 20091218112714 j Yee 1 z

    3/40

    FB530/FB630 ZSME3000001591

    EXCELL PRECISION CO., LTD.

    Table of ContentsInstructions for Use .................................................................................................................... 2

    Preparing to Use the Indicator ................................................................................................... 2

    Chapter 1 General Introduction ................................................................................................. 3

    1-1 Display Description ........................................................................................................... 3

    1-2 Power Descr iption ............................................................................................................. 4

    1-3 Keypad Description ........................................................................................................... 5

    Chapter 2 General Operation Description................................................................................. 6

    2-1 Backlight Function ............................................................................................................ 6

    2-2 Weighing Mode.................................................................................................................. 6

    (1). Units Select ion............................................................................................................... 6

    (2). Check Weighing Mode .................................................................................................. 6(3). Totalizing........................................................................................................................ 8

    (4). Zero Funct ion................................................................................................................. 8

    (5). Tare Function ................................................................................................................. 9

    (6). Printing Funct ion (only for FB model) ....................................................................... 10

    2-3 Counting Funct ion .......................................................................................................... 12

    (1). Sampl ing ...................................................................................................................... 12

    (2). Check Weighing........................................................................................................... 12

    (3). Totalizing...................................................................................................................... 12

    Chapter 3 General Funct ion Setting ........................................................................................ 13

    Check weighing configuration ............................................................................................. 14

    RS-232 Interface (opt ion) and Mini Printer Output Setting ................................................ 15

    Exit Setting Mode .................................................................................................................. 25

    Weight Hold Mode setting .................................................................................................... 26

    G value Calibration ................................................................................................................ 28

    Load Cell Pin Description (input signal) ................................................................................. 29Option Function Description.................................................................................................... 30

    Error Messages ......................................................................................................................... 30

    Appendix 1 ASCII Code Table ............................................................................................... 31

    Appendix 2 7-Segment Display Characters ......................................................................... 32

    Appendix 3 Printer Installat ion.............................................................................................. 33

    Appendix 4 Load Hook Installation ....................................................................................... 34

  • 8/13/2019 20091218112714 j Yee 1 z

    4/40

    FB530/FB630 ZSME3000001592

    EXCELL PRECISION CO., LTD.

    Instructions for Use1. The indicator should not be drenched by rain or water. (If it gets wet carelessly, please

    wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for

    service.

    2. Please keep the indicator in a cool and dry place. Do not store at high temperatures or

    humid places.

    3. Please keep the indicator clean and free from insect infestation.

    4. To avoid impact and it is to be used under designated pressure (the weight put on the

    platter can not exceed the maximum capacity of the indicator)

    5. If the indicator is not going to be used for some time, please clean it and store it in a

    plastic bag in dry condition. A desiccant sachet may be included to prevent moisture from

    building up. The internal rechargeable battery should be recharged every three months.

    6. Any suggestion for the product is warmly welcome.

    Preparing to Use the Indicator1. Put the indicator on a firm and flat surface for accurate weighing reading. Adjust the four

    leveling feet to get the leveling bubble at the center of the circle.

    2. The indicator must be used under a stable temperature and stable air flow. Avoid direct

    sunlight onto the indicator or near the air-conditioning outlet.

    3. Indicator must be used under individual socket to avoid the interference of other electric

    appliances.

    4. Remove any weight that might be on the platter before the indicator is switched on.

    5. The indicator requires 15 ~ 20 minutes warm up before operation to ensure best

    accuracy.

    6. Please note that when symbol appears on the screen, the indicator needs to be

    recharged.

    Thank you for purchasing EXCELL (Conversion)

    Dot Matrix Printer Indicator. To guide you to use

    our product correctly, please read the user manual

    carefully to avoid mis-operating this product.

  • 8/13/2019 20091218112714 j Yee 1 z

    5/40

    FB530/FB630 ZSME3000001593

    EXCELL PRECISION CO., LTD.

    Chapter 1 General Introduction

    1-1 Display Description

    Changes of Range indication mode

    The indicator with 2-segment specification:

    6 is Range 1 5 is Range 2

    : High limit value

    : OK value (The value between HI and LO limit value)

    : Low limit value

    : kg or g unit

    : Pound unit

    : Taiwan and Hong Kong units: Counting mode indication

    : Percentage: Zero indication

    : Net weight indication

    : Low battery power indication

    1 : Stable indication

    2 : Pretare mode indication

    3 : Accumulation mode indication

    4 : Printer ready indication (Mini Printer connection)

    5: Samples insufficient indication

    6 : Unit weight insufficient indication

    7 : Viss unit (Burma unit)

    1 2 3 4 75 6

  • 8/13/2019 20091218112714 j Yee 1 z

    6/40

    FB530/FB630 ZSME3000001594

    EXCELL PRECISION CO., LTD.

    1-2 Power Description

    Power Selection

    1. 6 V / 4 Ah Rechargeable battery

    2. 110 / 220 V 15%AC Main power

    Recharge Voltage

    1. AC 110 V +10% , -15%

    2. AC 220 V +10% , -15%

    Power Consumpt ion

    State Power ConsumptionContinue Operation

    Timedo not print(indicator + Load Cell + 2 sides

    backlight + Mini Printer)Less than 55 mA Over 70 hoursWith a load cell

    (350 )

    printing(indicator + Load Cell + 2 sides

    backlight + Mini Printer)Less than 350 mA Over 10 hours

    (indicator + Load Cell) 26 mA About 180 hours

    (indicator + Load Cell + frontdisplay backlight)

    32 mA About 140 hoursWithout aprinter

    (indicator + Load Cell +reardisplay backlight) 40 mA About 110 hours

    Only RS-232Card

    About 20 mA

    Low Power Alarm

    Please note when the ( ) symbol keeps flashing on the left down corner of the display, the

    batteries should be charged.

    The indicator will turn off automatically after 5 ~10 hours (approximately 1~2 hours with

    backlight on), when the low battery warning symbol shows up. The indicator must be fully

    charged, before operating again.

    When the low battery warning symbol shows up, please charge the indicator immediately for

    fear of weight instability.

    The indicator becomes unstable because of the large power consumption. Not be allowed

    taking off the battery when equipped with mini printer.

    EEPROM Power (for model with mini printer)

    When using the rechargeable battery but AC power and the voltage is below 3 V, the data of

    date, time, etc in RTC IC will disappear in 24 hours.

  • 8/13/2019 20091218112714 j Yee 1 z

    7/40

    FB530/FB630 ZSME3000001595

    EXCELL PRECISION CO., LTD.

    1-3 Keypad Description

    : Press this key to select the required unit from the preset units.

    : Press this key to preset the HI, OK, LO value.

    : Press this key to accumulate the weight value or others.

    : Press this key to deduct the container weight.

    : Press this key to preset tare value.

    :Press this key to recall the accumulation value, preset value and pretare value.

    :Press this key to clear the accumulation value, preset value and pretare value.

    : Press this key to zero the indicator.

    : Press this key to confirm.

    : Press this key to light up the backlight.

    : Press this key to enter into counting mode.

    : Press this key to sample.

    : Press this key to print the total data.

    : Press this key to input the numbers (0 ~ 9).

    : Press this key to advance the paper.

  • 8/13/2019 20091218112714 j Yee 1 z

    8/40

    FB530/FB630 ZSME3000001596

    EXCELL PRECISION CO., LTD.

    Chapter 2 General Operation Description2-1 Backlight Function

    Press key to choose the display backlight mode:

    . Auto Backlight mode. When the weight is over 10d or any key is

    pressed, the display backlight will be switched on. When the weight

    returns to zero (the weight on platform is less than 10d), the display

    backlight will switch off after 10 seconds.

    . Display backlight is on all the time.

    . Display backlight is off.2-2 Weighing Mode

    (1). Units Selection

    The selected unit will be memorized when you turn the indicator off. And the memorized unitwill appear after you turn on the indicator next time.

    (2). Check Weighing Mode

    1. Preset High limit, Low limit and Beeper value operation

    Use and key to preset values.

    For example:

    Preset Low limit ( Low limit >10d ) e.g. Low limi t = 20 kg

    Press key the display shows .

    Press key 1 time the display shows .Press key 2 times the display shows .

    Press key 4 times the display shows .

    Preset High limit ( High limit Low limit ) e.g. High limit = 25 kg

    Press key 1 time the display shows .

    Press key 1 time the display shows .

    Press key 2 times the display shows .

    Press key 1 time the display shows .

    Press key 5 times the display shows .

    Press key 3 times the display shows .

    Preset Beeper value ( Refer to Note) e.g. Beeper value = 22

    Press key 1 time the display shows

    Press key 2 times the display shows

    Press key 1 time the display shows

    Press key 2 times the display shows

    Press key 1 times the display shows .

  • 8/13/2019 20091218112714 j Yee 1 z

    9/40

    FB530/FB630 ZSME3000001597

    EXCELL PRECISION CO., LTD.

    Preset Single point (preset low limit only):

    After preset low limit procedures is completed and the display shows . ,

    then press key again, the display shows . . This means that the preset single

    point procedure is completed.

    NOTE

    _ _ _ x xA B

    A Setting for the status that LCD is on and the beeper beep:

    0 = when stable, the beeper beeps and LCD is on.

    1 = when stable, the beeper beeps; whether stable or not, LCD is on.

    2 = whether stable or not, the beeper beeps and LCD is on.

    B Setting for the beep status:

    0 = No beep1 = OK (when the weight is over Low Limit & under or equal to High Limit.), the

    beeper beeps.

    2 = When the weight is under or equal to Low Limit & over High Limit, the beeper

    beeps.

    Under Status in Preset Low Limit (preset single point only)The BEEP, LCD mode should be fixed as follows:

    When over Low Limit, the beeper beeps and is offWhether stable or not, the beeper beeps and LCD indication is on

    LCD indication:

    10d Low Limit High Limit

    To exit preset mode, please press key.

    2. Recall Check-weighing ValuesPress key then press key Recall Low limit value

    Then press key again Recall High limit value

    Then press key again Recall Beeper value

    Then press key again Back to the beginning

    3. Clearing Check-weighing Values

    Press key then press key, and then press key Recall Low limit value

    Then press key again Clear High limit value and Beeper value

    Press key then press key 6 times continuously Clear all values

  • 8/13/2019 20091218112714 j Yee 1 z

    10/40

    FB530/FB630 ZSME3000001598

    EXCELL PRECISION CO., LTD.

    (3). Totalizing

    1. Weight Totalizing

    Place goods on the platter, after stable and press key to save the weight value.

    Then the display shows the total number of additions and the totalized weight value.

    And the (M+) indication

    will flash on the display. The indicator will recover to show theweight value of the goods on the platter after 3 seconds and the (M+) indication is on.

    The indicator allows the next totalizing operation, even when the weight value does not

    return back to zero. The key is functional, when the weight value changes by more

    than 10d. The indicator will save the totalized weight value after the weight is stable.

    The indicator can totalize positive or negative weight but cant do both at the same time.

    The totalized weight store must be reset to zero before it is possible to select positive or

    negative totalizing mode.

    The totalizing function can be used up to a maximum of 9999 times before it must be reset.

    The totalizing display is limited to 6 digits maximum.

    When totalizing, RS-232 and Mini Printer will also output. ( Refer to F5 setting)

    2. Clear Totalized Weight Values

    Press then key to clear all totalized weight values.

    When changing between weighing and counting mode, or selecting weighing unit, the

    indicator will automatically clear all the totalized weight values.The indicators will automatically clear all the totalized weight values after turning on.

    3. Recall Totalized Weight Values

    Press key to display the total number of additions and the totalized weight value.

    And the (M+) indication will flash on the display. The indicator will return to the weighing

    mode after 3 seconds.

    The indicator will not display the negative sign - for negative totalized weight values whenrecalling a totalized weight value, but when printing, the negative sign - will be printed out

    (transmitted serially) for each negative weight and negative totalized weight.

    (4). Zero Function

    Press key to re-zero the display with no load on the platter. When zero is set, the

    ( ) symbol will be displayed.

  • 8/13/2019 20091218112714 j Yee 1 z

    11/40

    FB530/FB630 ZSME3000001599

    EXCELL PRECISION CO., LTD.

    (5). Tare Function

    1. When the weight of the container is unknown ( )

    Place the container on the platter, after stable and press key, the weight value

    returns to zero and net indication ( ) is on.

    Place goods into the container, then the indicator shows the net weight of goods.

    Clear tare value

    When removing the container and goods, the display shows the negative weight value of

    the container. Then press key to clear tare value. The indicator returns to zero and

    net indication ( ) is on.

    Recall tare value

    Press then keythe display shows tare value

    Multiple tare operation Users can continuously increase or decrease the tare value by

    pressing the key.

    The total tare value (tare value + pre-set tare value) can equal the full capacity of the indicator.

    2. When the weight of the container is known ( )

    Press key and the display shows . .

    Use and keys to input weight value of the container. After finishing the

    procedures, the net indication ( ) and pretare indication is on.

    Place goods into the container, then the indicator shows the net weight of goods.

    Clear pretare value

    Press then key, and then press key to clear pretare value.

    When the indicator returns to zero, net indication ( ) and pretare indication are

    off.

    Recall pretare valuePress then keythe display shows pretare value

    In Tare mode, the Preset tare function is disabled.

    The indicators with two weighing ranges can NOT pre-set the tare value larger than the first

    weighing range. For example: a 30 kg indicator is set by two weighing ranges. The first range

    is 0 to 15 kg, and the second range is 15 to 30 kg. The pre-set tare value can not be larger

    than 15 kg.

  • 8/13/2019 20091218112714 j Yee 1 z

    12/40

    FB530/FB630 ZSME30000015910

    EXCELL PRECISION CO., LTD.

    (6). Printing Function (only for FB model)

    F5 Function Press key Press keyPress key twice

    after zeroing

    RS-232 closed

    r n p 0 Printer closed

    RS-232 and

    Printer do nottransmit

    RS-232 and

    Printer do nottransmit

    RS-232 and Printerdo not transmit.

    Totalized values donot clear off

    When weight is stable,RS-232 transmits

    automatically(when re-zeroed,

    RS-232 transmits nexttime after stable.)

    r n p 1

    Printer closed

    RS-232 andPrinter do not

    transmit

    RS-232 andPrinter do not

    transmit

    RS-232 and Printerdo not transmit.

    Totalized values donot clear off

    RS-232

    continuously transmitsr n p 2

    Printer closed

    RS-232

    transmitsPrinter does not

    transmit

    RS-232

    transmitsPrinter does not

    transmit

    RS-232 transmits

    Printer does nottransmitTotalized values do

    not clear off

    RS-232totalizes and transmits

    RS-232transmits whenweight changes

    by over 10d

    RS-232transmits whenweight changes

    by over 10d

    RS-232 prints TOTALand clears totalized

    valuesr n p 3

    Printertotalizes and transmits

    Printertransmits whenweight changes

    by over 10d

    Printertransmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    values

    RS-232totalizes and transmits

    RS-232transmits whenweight changes

    by over 10d

    RS-232transmits whenweight changes

    by over 10d

    RS-232 prints TOTALand clears totalized

    valuesr n p 4

    Printertotalizes and transmits

    Printertransmits whenweight changes

    by over 10d

    Printertransmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    values

    When weight is stable,

    RS-232 totalizes andtransmits automatically(when re-zeroed,

    RS-232 transmits nexttime after stable and.weight changes by

    over +10d)

    RS-232 doesnot transmit

    RS-232 doesnot transmit

    RS-232 prints TOTALand clears totalized

    values

    r n p 5When weight is stable,

    Printer totalizes andtransmits automatically

    (when re-zeroed,

    Printer transmits nexttime after stable and.weight changes by

    over +10d)

    Printer does not

    transmit

    Printer does not

    transmit

    Printer prints TOTAL

    and clears totalizedvalues

  • 8/13/2019 20091218112714 j Yee 1 z

    13/40

    FB530/FB630 ZSME30000015911

    EXCELL PRECISION CO., LTD.

    RS-232totalizes and

    transmits

    RS-232transmits whenweight changes

    by over 10d

    RS-232transmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    valuesr n p 6

    Printertotalizes and

    transmits

    Printertransmits whenweight changes

    by over 10d

    Printertransmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    values

    RS-232totalizes and

    transmits

    RS-232transmits whenweight changes

    by over 10d

    RS-232transmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    valuesr n p 7

    Printertotalizes and

    transmits

    Printertransmits whenweight changes

    by over 10d

    Printertransmits whenweight changes

    by over 10d

    Printer prints TOTALand clears totalized

    values

    After RS-232 is

    stable , presskey to transmit

    RS-232 doesnot transmit

    RS-232transmits whenweight changes

    by over 10dr n p 8

    Printer closedPrinter does not

    transmitPrinter does not

    transmit

    RS-232 and Printer donot transmit.

    Totalized values do notclear off

    Note: press and keys respectively to print labels of different forms.

  • 8/13/2019 20091218112714 j Yee 1 z

    14/40

    FB530/FB630 ZSME30000015912

    EXCELL PRECISION CO., LTD.

    Pcs

    .

    . .

    . . .

    . . . .

    2-3 Counting Function(1). Sampling

    Press key to select sample quantity from 10,20,50,100 and the display shows

    , , , accordingly.

    Select sample quantity and then place samples on the platter, and then press key,

    the display shows .

    After stable, the indicator enters into counting mode and the display shows sample

    quantity.

    Insufficient Sample ( ) Sample weight is less than 20 divisions.

    Insufficient Unit Weight ( ) Unit weight is less than 0.2 division.

    When sampling, the above two symbols indications are on. Under such conditions, the

    indicator can still work, but may result in lower count accuracy.

    When using 2-segment weighing mode, the above two symbol indications change to

    Range 2 and Range 1 and the two symbol indications are off.

    (2). Check WeighingRefer to the operation of check weighing in weighing function on page 7 ~ 8.

    (3). TotalizingRefer to the operation of totalizing in weighing function on page 9.

  • 8/13/2019 20091218112714 j Yee 1 z

    15/40

    FB530/FB630 ZSME30000015913

    EXCELL PRECISION CO., LTD.

    Chapter 3 General Function Setting Switch on the indicator. While the indicator is counting down to zero, press and hold key

    until the display shows the software program version number.

    Release the key, the indicator enters into the configuration setting mode and is

    showed on the display.

    Internal calibration (Reserved)

    Internal calibration (Reserved)

    Internal calibration (Reserved)

    Internal calibration (Reserved)

    Check weighing configuration

    RS-232 interface (option) or MiniPrinter output setting

    Exit setting mode

    Internal calibration (Reserved)

    Weight hold mode setting

    Internal calibration (Reserved)

    G value Calibration

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

    Press keyPress key

  • 8/13/2019 20091218112714 j Yee 1 z

    16/40

    FB530/FB630 ZSME30000015914

    EXCELL PRECISION CO., LTD.

    Press key

    Press key

    Press key

    Check weighing configuration

    F8 (Hold) affects accessing to F4. If F8 is set, accessing to F4 is denied.

    Press or key to select F4 functionthe display shows

    Preset LO value

    (LO value >10d)

    Press andkey to set LO value

    E.g. LO value = 2 kg

    Preset HI value

    (HI value LO value)

    Press and

    key to set HI valueE.g. LO value = 2.5 kg

    Preset Beeper value

    Press and

    key to set HI valueE.g. Beeper value = 22

    . kg

    . kg

    Press key for 5 timesto clear HI, OK, LO values

    Press key

    . kg

    key = Increase the flash value by one (from 0 to 9)

    key = Confirmation key .

    kg

    A BA 0 = After stable, the beeper beeps and the

    indications are on1 = After stable, the beeper beeps; whether

    stable or not, the indications are on.2 = whether stable or not, the beeper beeps

    and the indications are on.B 0 = No beep

    1 = OK (when the weight is between Low limit& High limit.), the beeper beeps.

    2 = When the weight is under or equal to Lowlimit (must be over 10d) & over or equalto High limit, the beeper beeps.

    LCD indication description:

    10d Low limit value High limit value

    . kg

    kg

    kg

    Press key

  • 8/13/2019 20091218112714 j Yee 1 z

    17/40

    FB530/FB630 ZSME30000015915

    EXCELL PRECISION CO., LTD.

    RS-232 Interface (option) and Mini Printer Output Setting J1 and J3 on the RS-232 interface are short, when the RS-232 interface is connected to a

    computer.

    Mini Printer interface is set as 9 600, N 8 1, including the date and time setting.

    You are welcome to check with your local supplier to get a soft copy of EXCELL's

    Printing Title Editing Program (a Windows-based application software)

    Press or key to select F5 functionthe display shows

    Press keyThe display shows the defaultValue of transmission mode

    Press keySelect transmission mode

    Press keyThe display shows the defaultvalue of RS-232 baud rate

    Press keySelect RS-232 baud rate(1 200, 2 400,4 800,9 600)

    Press key

    Next Page

    key = Increase the flash value by one (from 0 to9) or selecting baud rate from 1 200,2 400,4 800,9 600

    key =Confirmation key

    No transmission (none)Stable transmission (RS-232)Continuous transmission (RS-232)Press key to transmit (simple mode)(RS-232, Mini Printer)Press key to transmit (Complete

    mode) (RS-232, Mini Printer)

    Stable transmission (totalizing mode).The format is as same as(RS-232, Mini Printer)

    Date and time printing modeThe format is as same as

    (RS-232, Mini Printer)

    Date and time printing modeThe format is as same as(RS-232, Mini Printer)

    After stable, press key to transmitThe format is as same as

    and . (RS-232)

    (from 0 ~ 8 )

  • 8/13/2019 20091218112714 j Yee 1 z

    18/40

    FB530/FB630 ZSME30000015916

    EXCELL PRECISION CO., LTD.

    Press key

    Press key

    Connect Mini Printer before cont inue

    Last Page

    Press keyto select printing language

    Press key

    Refer to Pages 18~ 23 for details of DATA FORMAT

    Mini Printer Printing Language

    Reserved

    English

    Traditional Chinese

    Reserved

    Default setting: Reserved

    Date Printing Order Setting

    YY MM DD

    MM DD YY

    DD MM YY

    Default setting: YY MM DD

    Press keyto select printingdate order

    Press key

    Press key

    Press key

    Input YY MM DD

    Input HH MM DD

  • 8/13/2019 20091218112714 j Yee 1 z

    19/40

    FB530/FB630 ZSME30000015917

    EXCELL PRECISION CO., LTD.

    RS-232 Interface FormatI . Mode :UART Signal of EIA-RS0232 C

    II. Format :1. Baud rate : 1 200, 2 400, 4 800, 9 600

    2. Data bits : 8 bits3. Parity bit : None4. Stop bits : 1 bit5. Code : ASCII (Exchange code of American standard)

    Start bit Data bits Stop bit

    RS-232 Data Format

    Stable transmission ( ),Continuous transmission ( ),

    Press key to transmit ( )(1) Weight unit is g

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g

    HEAD , HEAD , DATA UNIT CR LF

    (2) Weight unit is kg or lb

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 kg/lb

    HEAD , HEAD , DATA UNIT CR LF

    (3) Weight unit is viss

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 viss

    HEAD , HEAD , DATA UNIT CR LF

    HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )

    OL - Overload , Under loadST - Display is Stable NT - NET Mode

    US - Display is Unstable GS - GROSS Mode

    DATA ( 7 or 8 BYTE )

    2D ( HEX ) = ( MINUS )2B ( HEX ) = + 2E ( HEX ) = . ( DECIMAL POINT )

    UNIT ( 2 or 4 BYTE )

    kg = 6B ( HEX ) ; 67 ( HEX )lb = 6C ( HEX ) ; 62 ( HEX )viss = 76 ( HEX ) ; 69 ( HEX ) ; 73 ( HEX ) ; 73 ( HEX )

  • 8/13/2019 20091218112714 j Yee 1 z

    20/40

    FB530/FB630 ZSME30000015918

    EXCELL PRECISION CO., LTD.

    Transmission example:

    Data format for RS-232 continuous transmission are as below:

    1. The gross weight (+0.876 kg) shows as below, after stable: (no tare or under pretare mode)

    S T , G S , + 0 0 0 . 8 7 6 k g 0D 0A

    HEAD , HEAD , DATA UNIT C LF

    2. The net weight (-1.568 lb) shows as below without weight stability: (no tare or under pretare mode)

    U S , N T , - 0 0 1 . 5 6 8 l b 0D 0A

    HEAD , HEAD , DATA UNIT C LF

    3. The net weight (+1.245 viss) shows as below, after stable: (no tare or under pretare mode)

    S T , N T , + 0 0 1 . 2 4 5 v i s s 0D 0A

    HEAD , HEAD , DATA UNIT C LF

    Press key to transmit (simple mode)

    English

    S/N WT/UNIT ( kg / lb )

    - - - - - - - - - - - - - -

    0001 1.0000 Press or key

    0002 1.0000 Press or key

    0003 1.0000 Press or key

    0004 1.0000 Press or key

    0005 1.0000 Press or key

    - - - - - - - - - - - - - -

    0005 5.0000 Press twice to print TOTAL

    Besides English, the model is able to choose Traditional Chinese as printing

    form.

  • 8/13/2019 20091218112714 j Yee 1 z

    21/40

    FB530/FB630 ZSME30000015919

    EXCELL PRECISION CO., LTD.

    Stable Transmission (totalizing mode)

    English

    S/N WT/UNIT ( kg / lb )

    - - - - - - - - - - - - - -

    0001 1.0000 The indicator is stable

    0002 1.0000 The indicator is stable

    0003 1.0000 The indicator is stable

    0004 1.0000 The indicator is stable

    0005 1.0000 The indicator is stable

    - - - - - - - - - - - - - -

    0005 5.0000 Press twice to print TOTAL

    Besides English, the model is able to choose Traditional Chinese as printing

    form.

  • 8/13/2019 20091218112714 j Yee 1 z

    22/40

    FB530/FB630 ZSME30000015920

    EXCELL PRECISION CO., LTD.

    Press key to transmit (complete mode)

    English

    4-key serial 15 or 12-key serial

    Press or key Press or key

    Press or key

    Press or key

    Press or key

    Press or key

    Press twice to print

    TOTAL

    Press twice to printTOTAL

    G = GROSS T = TARE PT = PRE-TARE N = NET

    Besides English, the model is able to choose Traditional Chinese as printing

    form.

    TICKET NO .0001

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    TICKET NO .0002

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    TICKET NO .0003

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    TOTAL NUMBER

    OF TICKETS 0003

    TOTAL

    NET 3.000kg

    (3 blank lines)

    TICKET NO .0001

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    TICKET NO .0002

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    TICKET NO .0003

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    TOTAL NUMBER

    OF TICKETS 0003

    TOTALNET 3.000kg

    (3 blank lines)

  • 8/13/2019 20091218112714 j Yee 1 z

    23/40

    FB530/FB630 ZSME30000015921

    EXCELL PRECISION CO., LTD.

    RTC setting , the form is the same with

    Press key to transmit (simple mode) (The date and time will not betransmit without mini printer.)

    English

    DATE:2008/02/25TIME : 14:30:21S/N WT/UNIT ( kg / lb )

    - - - - - - - - - - - - - -

    0001 1.0000 Press or key

    0002 1.0000 Press or key

    0003 1.0000 Press or key

    0004 1.0000 Press or key

    0005 1.0000 Press or key

    - - - - - - - - - - - - - -

    0005 5.0000 Press twice to print TOTAL

    Besides English, the model is able to choose Traditional Chinese as printing

    form.

  • 8/13/2019 20091218112714 j Yee 1 z

    24/40

    FB530/FB630 ZSME30000015922

    EXCELL PRECISION CO., LTD.

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 00

    TICKET NO .0001

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 00

    TICKET NO .0002

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 00

    TICKET NO .0003

    G 1.000kg

    T 0.000kg

    PT 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 00

    TOTAL NUMBER

    OF TICKETS 0003

    TOTAL

    NET 3.000kg

    (3 blank lines)

    RTC setting , the form is the same with

    Press key to transmit (complete mode) (The date and time will notbe transmit without mini printer.)

    English

    4-key serial 15 or 12-key serial

    Press or key Press or key

    Press or key Press or key

    Press or key

    Press or key

    Press twice to printTOTAL

    Press twice to printTOTAL

    Besides English, the model is able to choose Traditional Chinese as printingform.

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 00

    TICKET NO .0001

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 20

    TICKET NO .0002

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 30 : 40TICKET NO .0003

    G 1.000kg

    T 0.000kg

    N 1.000kg

    (3 blank lines)

    DATE: 2008 / 02 / 25

    TIME: 14 : 31 : 10

    TOTAL NUMBER

    OF TICKETS 0003

    TOTAL

    NET 3.000kg

    (3 blank lines)

  • 8/13/2019 20091218112714 j Yee 1 z

    25/40

    FB530/FB630 ZSME30000015923

    EXCELL PRECISION CO., LTD.

    RS232 and mini pr inter data transmission format in HOLD condition

    Please set in .

    When is set as or

    , 1.000kg models format is as follows.

    The format is as follows for 1.000kg model.

    1 . 0 0 0 k g 0D 0A

    PN (part No. )SN (Serial No.)

    Setting Methods

    Press and hold key for two seconds to enter in weighing mode.

    About onesecond

    6 Press and key to input12 sets of Part number.

    About onesecond

    6 Press and key to input12 sets of Serial number.

    Remarks1. PN and SN values will come back to zero when power off.2. The type of mini printer is different for different languages.

    Press key once, SN value willincrease one digit.

    Press key once,PN value is fixed.

  • 8/13/2019 20091218112714 j Yee 1 z

    26/40

    FB530/FB630 ZSME30000015924

    EXCELL PRECISION CO., LTD.

    Self-test Function of Printer (optional)Press and hold key to automatically print self-test data.

    ------------VERSION 10004010 Program version

    DATE 2000/01/04 Printer dateTIME 200650 Printer time

    MODE TAIWAN Printer language

    MEMORY TEST OK Printer status

    The test of Printer

    1. Press and hold key to enter into.

    Default20

    2. Press or key to adjust the number.

    3. Press key to print.4. Input the proper number to adjust the distance.

    (large distance, adjust high)

    (goodstandard)

    (short distance, adjust low)

    5. Press key to power on.

  • 8/13/2019 20091218112714 j Yee 1 z

    27/40

    FB530/FB630 ZSME30000015925

    EXCELL PRECISION CO., LTD.

    Exit Setting Mode

    Press or key to select F6function the display shows

    Press key

    Counting down tozero and exit setting

    mode

  • 8/13/2019 20091218112714 j Yee 1 z

    28/40

    FB530/FB630 ZSME30000015926

    EXCELL PRECISION CO., LTD.

    Weight Hold Mode setting

    Under hold mode, press key to print the hold value showed.

    (Select proper baud rate according to receiver and F5 transmission mode does not affect)

    (Refer to F5 for details of transmission rate)

    Please make sure MINI JUMPER of SWA1 is connected to ADJ on PC board before setting.

    Please make sure MINI JUMPER of SWA1 is connected to LOCK on PC board after setting.

    Press or key to select F8 functionthe display shows

    Press key in order and the displayshows accordingly

    ~Select required hold mode and then press

    key to finish setting.

    Press key

    Press key

    Press key

    Press key

    Press key

    Press key

  • 8/13/2019 20091218112714 j Yee 1 z

    29/40

    FB530/FB630 ZSME30000015927

    EXCELL PRECISION CO., LTD.

    Animal scale hold mode setting

    Choose hold 4

    Press key

    Setting Error Range

    Press and keys to set error rangefrom 1% ~ 100%Default setting: 10%

    %

    Average Trade Count Setting

    Press and keys to set from 1.2.4.8.16.32.64.Default setting: 8

    %

    Press key

    Press key

    Press key

    Press key

    Press key

    Hold functionDisableWhen the weight keeps changing, the indicator will automatically hold

    and display the largest value.

    Press any key except key to clear the hold value.

    When the indicator becomes stable, the display shows and holds theweight value, which can not be changed.

    Press any key except key to clear the hold value.

    When the indicator becomes stable, the display shows and holds the

    weight value, which can not be changed.

    When the indicator is re-zeroed (weight less than 10d), the hold value is

    automatically cleared.

    Animal scale. When the animal is on the platter, the display shows the

    weight value, which can not be changed.

    When the animal leaves the platter (weight less than 10d), the indicator is

    re-zeroed automaticall .

  • 8/13/2019 20091218112714 j Yee 1 z

    30/40

  • 8/13/2019 20091218112714 j Yee 1 z

    31/40

    FB530/FB630 ZSME30000015929

    EXCELL PRECISION CO., LTD.Load Cell Pin Description (input signal)

    1. EXC+2. EXC-3. SIG+4. SIG-5. Shield

    4-wire or 5-wire Load Cell (L/C)FB model

    JP 21,JP 22 Short

    PCB L/C

    (E+) connect to EXC+

    (E -) connect to EXC -

    (S+) connect to SIG+

    (S -) connect to SIG -

    (FG) connect to Shield

    Note: JP 21 and JP 22 are on the PCB in FB Model.

  • 8/13/2019 20091218112714 j Yee 1 z

    32/40

    FB530/FB630 ZSME30000015930

    EXCELL PRECISION CO., LTD.

    Option Function DescriptionRS-232 output description (for FB model)

    1. RS-232 OPTION Card : AD05135 = > 4 PIN connect to CN8 of main board

    2. Please refer to F5 function settings for transmission mode, baud rate setting and data

    format.

    3. RS-232 (DB 25PIN) Pin Description

    J1, J3 SHORT; J2, J4 OPEN (default setting)

    Pin 2 RXDPin 3 TXDPin 7 GNDOther pins are disabled.

    J2, J4 SHORT; J1, J3 OPEN

    Pin 2 TXDPin 3 RXDPin 7 GNDOther pins are disabled.

    Error MessagesOL The scale is over full scale +9d.

    E1 Zero value after power on is over 10% FS when JP5 on the PCB in FB model is short.

    E2 Zero value after power on is less than10% FS when JP5 on the PCB in FB model is short.

    E4 Re-zero is unstable. When it is over 10 seconds, press 0 to exit E4.

    E6 Zero value is over 550 000 when calibrating.

    E7 Zero value is less than 150 000 when calibrating.

    E10 LEVEL Switch Function: JP2 on the PCB in FB model is open, connect the signal toCN1. When CN1 is open, the display will disappear and then show E10. When CN1 is short, the

    scale can be weighed in general condition. If not using LEVEL Switch Function, please JP2 is

    set to be short.

  • 8/13/2019 20091218112714 j Yee 1 z

    33/40

    FB530/FB630 ZSME30000015931

    EXCELL PRECISION CO., LTD.

    Appendix 1 ASCII Code Table

    Symbol ASCII Code Symbol ASCII Code Symbol ASCII Code

    A 41H a 61H 0 30H

    B 42H b 62H 1 31H

    C 43H c 63H 2 32H

    D 44H d 64H 3 33H

    E 45H e 65H 4 34H

    F 46H f 66H 5 35H

    G 47H g 67H 6 36H

    H 48H h 68H 7 37H

    I 49H i 69H 8 38H

    J 4AH j 6AH 9 39HK 4BH k 6BH 0DHL 4CH l 6CH

    M 4DH m 6DH

    N 4EH n 6EH

    O 4FH o 6FH

    P 50H p 70H

    Q 51H q 71H

    R 52H r 72HS 53H s 73H

    T 54H t 74H

    U 55H u 75H

    V 56H v 76H

    W 57H w 77H

    X 58H x 78H

    Y 59H y 79H

    Z 5AH z 7AH

  • 8/13/2019 20091218112714 j Yee 1 z

    34/40

    FB530/FB630 ZSME30000015932

    EXCELL PRECISION CO., LTD.

    Appendix 2 7-Segment Display CharactersNumber Display Letter Display Letter Display

    0 A N

    1 B O

    2 C P

    3 D Q

    4 E R

    5 F S

    6 G T

    7 H U

    8 I V

    9 J W

    K X

    L Y

    M Z

  • 8/13/2019 20091218112714 j Yee 1 z

    35/40

    FB530/FB630 ZSME30000015933

    EXCELL PRECISION CO., LTD.

    Appendix 3 Printer InstallationA. Roll paper installation and problems solution1. Installation roll paper:

    Use designated roll paper with a width 44.5 0.5 mm and internal diameter 50 mm.

    Fix the roll paper into the paper entrance of the Printer. Cut the edge of the paper leveling and then install the paper (refer to Vof picture A).

    And then use Feedkey to complete installation (make sure the paper is parallel with the

    printing location. Avoid operating as Xof picture A )

    The paper should not be folded or broken.

    2. Uninstall roll paper:

    Cut up the paper at the entrance of Printer, and then

    pull out the paper from the exit of Printer.

    3. Paper jam solutions procedures:

    Uninstall the paper first.

    Use a nipper or others to clear remain wastepaper.

    B. Ribbon installation Use designated ribbon. (ERC-05)

    Uninstall the roll paper before install the ribbon. (Picture B)

    Turn and tighten the ribbon before installation.

    Sway the ribbon to proper location according to Picture C.

    If the ribbon loosens during installation, retighten

    it according to Picture D.

    To uninstall the ribbon, press gently the location in Picture E,and then take it out with proper adjustment.

    The ribbon of the model received may deviate its location during

    its transportation, and this may lead to the breakdown of the Printer.

    To solve this problem, reinstall the ribbon according to the

    above procedures.

    Picture E

    Picture D

    Picture C

    Picture B

    Picture A

  • 8/13/2019 20091218112714 j Yee 1 z

    36/40

    FB530/FB630 ZSME30000015934

    EXCELL PRECISION CO., LTD.

    Appendix 4 Load Hook InstallationPlease install the load hook (only for FB-630) according to correct order as follows.

  • 8/13/2019 20091218112714 j Yee 1 z

    37/40

  • 8/13/2019 20091218112714 j Yee 1 z

    38/40

  • 8/13/2019 20091218112714 j Yee 1 z

    39/40

  • 8/13/2019 20091218112714 j Yee 1 z

    40/40