Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
Hardware / SoftwareUnpacking and inspection of
shipped materials
solvent inlet/outlet
Priming each channel withIsopropanol from solvent bottleto pump inlet
InstallationNote: Shipping containers shouldnot be opened until an AgilentTechnologies representative is present
Purpose: To ensure that instrumentsand systems are correctly installedand functioning as designed, in thecustomer's facility. Correctinstallation is the first step inensuring that instruments andsystems operate reliably over anextended lifetime.
G1310A/11A/12A – Pump
Section NOT Applicable Unpack all boxes and place equipment on bench. To prevent injury, get liftingassistance if needed.
1. SN/FW#_____________________
2. SN/FW#_____________________ Retain shipping containers andmaterial until installation iscomplete and performance is
verified
3. SN/FW#_____________________
Customer Responsibilities The customer should ensure that theinstallation site is prepared inaccordance with the specificationscontained in the relevant site preparation document and that thenecessary operating supplies,consumables and usage dependentitems such as vials, paper, solvents,etc. are available. A customerrepresentative should be present atall times during the installation.
Set up the pump(s) Notify order fulfillment of any
discrepancies solvent inlet/outlet waste drain
Unpack and verify conditionand completeness of shipment remote control (if used)
relay contacts (if installed) Check serial numbers and fill in
installation documentation S/Nfields if necessary
seal wash tubing(if installed)
CAN Verify that power cords are
correct (must mate with powersockets) and are plugged into power receptacle
Agilent GPIB/LAN (see note*) Priming the pump
prepare solvents
turn on
When applicable, installcomputer system and connect all power interconnect cables
Note: Typical installation time is
1.5 hours for a system and 30
minutes for a module.
purge purge mobile phase monitor the pressure
If a G1315C-DAD or G1365C-MWD is added to an existing1100 system, all modules must be upgraded to firmwarerevision A.06.xx using theLAN/RS-232 FW Update Tool2.00 according to the updatedocumentation.
If installation time was not sold forany section, check that section asnot applicable.
G1382A G1376A Capillary Pump
G1379A Micro Degasser
G2225A G2226A Nano pump
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 1 of 6
Installation Checklist G1379A Micro Degasser
Section NOT Applicable Section NOT Applicable
G1322A/79A– DegasserNote:
If one section contains multiplechoices for installed Hardware please encircle all modules that are part of the system and fill in thecorresponding Serial Number.
1. SN/FW#_____________________ Section NOT Applicable
2. SN/FW#_____________________ 1. SN/FW#_____________________
Set up the pump2. SN/FW#_____________________
solvent inlet/outlet waste drain
Set up the degasser(s) remote control (if used)
-
8/17/2019 Inst Checklist 0405
2/6
Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
5065-9922 Prep. Manual Injector
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 2 of 6
relay contacts (if installed)
CAN Agilent GPIB/LAN (see note*) set up the degasser solvent inlet/outlet priming each channel with
Isopropanol from solvent bottle to pump inlet
Priming the pump prepare solvents turn on purge purge mobile phase
monitor the pressure
G1361A – Prep. Pump
Section NOT Applicable
1. SN/FW#_____________________
2. SN/FW#_____________________
Set up the pump(s) solvent inlet/outlet waste drain
remote control (if used) relay contacts (if installed) seal wash tubing CAN Agilent LAN (see note*)
Priming a prep pump Prime each pump individually Use the syringe + adapter +
tubing and connect to the wasteoutlet of the pump`s EMPV
Turn ON the pump and
electronically switch the EMPVto waste Manually suck the solvent into
and trough the pump Pump at least 0.5 liter of IPA
through the pump
G1328A/B – Manual Injector or
G1327A - Thermostat. ALS
Section NOT Applicable G1389A - Thermostat. Micro ALSG1364A/B/C/D + G1330A/B
SN/FW#________________________ Therm. Fraction Collector G1368A - Thermostat. WPS Setup the injector G1378A - Thermostat. Micro WPS
start/stop cable to pump G2261A - Thermostat. Preparative base plate & mounting pole position valve inlet/outlet connected sample loop vent tubes
G1313A/29A – Autosampler
G1387A – Micro ALS
G1367A - Well Plate Sampler
G1377A - Micro WPS
G2258A – Dual Loop ALS
G2260A - Preparative ALS
Section NOT Applicable
1. SN/FW#_____________________
2. SN/FW#_____________________
3. SN/FW#_____________________
Setup the autosampler(s) solvent inlet/outlet waste drain (must be in a
straight line down, no bends, kinks or curves
large volume tube(if installed)
BCD output (if installed) remote control (if used) relay contacts (if installed)
CAN Agilent GPIB/LAN (see note*)
The following section applies if aG1330A/B - ALS Thermostat
is installed together with any of thewell-plate-, autosamplers or fractioncollectors to generate a:
ALS
G1330A/B - ALS Thermostat
Section NOT Applicable
1. SN/FW#_____________________
2. SN/FW#_____________________
3. SN/FW#_____________________
Setup the ALS Thermostat(s)underneath the module(s) thathas (have) to be thermostatted
WARNING: Do not connect theALS thermostat cable while the line power is connected to the anyof the modules. This would damage
the sampler or fraction collector andthe thermostat electronics. air channel adapter and plate ALS thermostat cable ALS thermostat waste drain
G1316A - Column Compartment
Section NOT Applicable
SN/FW#________________________
Setup the TCC solvent inlet/outlet column waste drain remote control (if used) CAN GPIB (see note*)
-
8/17/2019 Inst Checklist 0405
3/6
Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
G1157A/58A/59A/60A/62A/63A remote control (if used)
Valves
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 3 of 6
Section NOT Applicable
1. SN/FW#_____________________
2. SN/FW#_____________________
3. SN/FW#_____________________
Setup the Valves Setup the 1100 Series Valve solvent inlet/outlet
CAN CAN-DC-In from other 1100
Module (e.g. G1367A WPS,G1364A/B/C/D FractionCollector or G1361A Prep.Pump)
G1383A Column Organizer
Section NOT Applicable
SN/FW#________________________
Setup the column organizer base plate and organizer plate rods traversesadditional holders (if used)
G1314A – VWD
Section NOT Applicable
SN/FW#________________________
Set up the detector flow cell
solvent inlet/outlet waste drain remote control (if used) analog output (if used) relay contacts (if installed) CAN Agilent GPIB/LAN (see note*)
Verify the operation of the
detector
analog output (if used) CAN Agilent GPIB/LAN (see note*) Lamp
IntensityPass/Fail
Verify the operation of thedetectorZero-order
DeviationWLcalibration Lamp
IntensityPass/Fail656nm
DeviationExcitationDeviationG1315A/B/C-DAD / G1365A/B/C-
MWD
Section NOT Applicable
1. SN/FW#_____________________
2. SN/FW#_____________________
Set up the detector(s) deuterium lamp
(if not installed)
solvent inlet/outlet waste drain remote control (if used) analog output (if used)
relay contacts (if installed) CAN Agilent GPIB/LAN (see note*) Verify the operation of the
detector
LampIntensity
1.2.
Pass/Fail
1.2.WL
calibration 1.2.
AlphaDeviationBetaDeviation
G1321A – FLD Section NOT Applicable
SN/FW#________________________
Set up the detector solvent inlet/outlet waste drain
WLverification Emission
Deviation
G1362A – RID
Section NOT Applicable
SN/FW#________________________
Set up the detectorWARNING: Make sure that all plugs are removed from the portsand the appropriate capillaries(inlet/outlet/recycling) areconnected (maximum backpressure
of 5 bar for flow cell). solvent inlet/outlet solvent recycle waste drain remote control (if used) analog output (if used) CAN Agilent GPIB/LAN (see note*)
Verify the operation of thedetector
Diode
Balance Value
G1364A/B/C/D – Fraction
Collector
Section NOT Applicable
1. SN/FW#_____________________
-
8/17/2019 Inst Checklist 0405
4/6
Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
2. SN/FW#_____________________
3. SN/FW#_____________________
4. SN/FW#_____________________
Setup the fraction collector(s) solvent inlet/outlet waste drain remote control (if used) relay contacts (if installed) CAN Agilent LAN (see note*)
G1390A – Universal Interface Box
(UIB)
Section NOT Applicable
SN/FW#________________________
Setup the universal interface box
CAN Analog In (if used) GPIO / Analog In (if used) Relay Contacts (if used)
Note: Agilent GPIB/LAN connectionis made between one (1) of the Agilent
1100 Series System modules and the
Agilent ChemStation PC. If a
detector is installed connect the
GPIB/LAN to this module.
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 4 of 6
-
8/17/2019 Inst Checklist 0405
5/6
Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
Software Installation (Un- 1100 LC CheckoutG1323A/B – Control Module
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 5 of 6
Section NOT Applicable
SN/FW#________________________
Set up the control module Connect via CAN to
available instrument module
Software Installation (Bundled)
Section NOT Applicable
Software
Product:_________________________
SoftwareRevision:________________________
Start Windows Start ChemStations -> Add
Licenses and add the licensenumbers. You find thesenumbers in the 'SoftwareCertificate and RegistrationPacket' envelopes.
Configure TCP/IP if the
instrument will be connectedusing LAN.
Install and Configure IOLibraries if instrument will beconnected using GPIB.
If necessary install andconfigure AGILENT BootpService if the instrument will beconnected using LAN.
Use the Configuration Editorand configure your instruments.
Install and Configure Software
Add-Ons (if applicable) If present, install the PC Image
software and create a backupusing the Backup Solution UserGuide as reference.
Bundled)
Start a run Section NOT Applicable Prepare:
1. pump(s)SoftwareProduct:_________________________
2. online degasser (s)(if present)
3. injection device(s)SoftwareRevision:_____________________
4. column compartment5. detector(s)6. fraction collector(s)
(if present) Start Windows Install ChemStation using the
ChemStation Installation guide
for reference.
7. Valve(s) (if present)8. recording device
Attach results to installationdocumentation
Check if a printer driver isinstalled on the system
Fill out instrument logbook Verify that the regional settings
are set to English-US Install and Configure TCP/IP if
the instrument will be connectedusing LAN.
Install and Configure IOLibraries if instrument will beconnected using GPIB.
If necessary install and
configure AGILENT BootpService if the instrument will beconnected using LAN
Use the Configuration Editorand configure your instruments.
-
8/17/2019 Inst Checklist 0405
6/6
Agilent 1100 Series
Liquid Chromatograph
Hardware and Software Installation Checklist
Service Review
Issued: April, 2005 – Rev. 5.0 N/A WAD LPA Product Support Page 6 of 6
Note: Password is the Registration
number for the software Affix any reports generated tothis Checklist
Sales Order Number Record in the instrumentlogbook date and time installwas completed
_________________________
Customer Service Order (CSO) Number
Explain Agilent warranty forHardware, Software and return policy for the InstrumentService Center
__________________________
Date completed Explain how to log aninstrument service call __________________________
Explain support services
Customer Signature
Explain how to use manuals Advise customer of additional
training options __________________________
Advise the customer of thefollowing useful AgilentWebSites:
Support Provider Signature
__________________________ e.g. 1100 Series Firmware(Downloads/patches)
Exclusive offers:
www.agilent.com/chem/exclusiveoffers
Library -http://www.agilent.com/chem/library
Education -www.agilent.com/chem/education
eSeminars -www.agilent.com/chem/eseminars
Software Status Bulletins and Patches -www.agilent.com/chem/techsupport
Supplies - www.agilent.com/chem/supplies
Tech Support -
www.agilent.com/chem/techsupp