Download - A301€¦ · CONTACT: ERIC KAUL EMAIL: [email protected] PHONE: 608-643-4100 [email protected] Due to electronic distribution, this drawing may not be printed to the

Transcript
Page 1: A301€¦ · CONTACT: ERIC KAUL EMAIL: EKAUL@RAMAKER.COM PHONE: 608-643-4100 MICHAEL.LOTTER@CO.MARATHON.WI.US Due to electronic distribution, this drawing may not be printed to the

2"

SC

HE

DU

LE

SE

E D

OO

R

SC

HE

DU

LE

SE

E D

OO

R

4"

0 3/8 "

SC

HE

DU

LE

SE

E D

OO

R

4"

0 3/8 "

SC

HE

DU

LE

SE

E D

OO

R

4"

0 3/8 "

3/8 "

4"

2"

3/8 "

SC

HE

DU

LE

SE

E D

OO

R

4"

SC

HE

DU

LE

SE

E D

OO

R

7'-5"

2 1/2 "3'-7"2 1/2 "

4'-0"

14'-0"

3'-0"

2 1/2 "3'-7"2 1/2 "

4'-0"

14'-0"

3'-0"

2 1/2 "

2'-0"

2 1/2 "

5'-7"

2 1/2 "

5'-7"

2 1/2 "

2 1/2 "

3'-9"

2 1/2 "

5'-8"

2 1/2 "

3'-9"

2 1/2 "

3'-0"

4'-0"

6'-0"

2 1/2 "

3'-7"

2 1/2 "

8'-0"

2 1/2 "

4'-7"

2 1/2 "

5'-0"

2 1/2 "

3'-7"

2 1/2 "

2 1/2 "

3'-7"

2 1/2 "

3'-0"

4'-0"

3'-0"

4'-0"

2 1/2 "

2'-0"

2 1/2 "

4'-9 1/2 "

2 1/2 " 2 1/2 "

3'-4 1/2 "

2 1/2 "

2'-0"

2 1/2 " 2 1/2 "

2'-0"

2 1/2 "

3'-2"

2 1/2 "

2'-0"

2 1/2 "

3'-0"

6"

8"6"

5"

5"

6½"

2'-0"

8'-0"

4'-2 1/2 "

3'-9 1/2 "

4'-5 1/2 "

2 1/2 "

16 1/4 "

2 1/2 "

2 1/2 "

16 1/4 "

2 1/2 "

3'-0"

4'-8"

2 1/2 "

4'-3"

2 1/2 "

ISSUANCES / REVISIONS

NO: DESCRIPTION: DATE:

ISSUANCES / REVISIONS

NO: DESCRIPTION: DATE:

0 CONSTRUCTION BID SET 06.17.2019

65361

JT

FM

JT

AQUATIC THERAPY

CENTER

1100 LAKE VIEW DRIVE

WAUSAU, WI 54403

MARATHON COUNTY &

NORTH CENTRAL

HEALTH CARE

PROJECT NUMBER

555 South River Street

Janesville, WI

608.756.2326

APPROVED BY

REVIEWED BY

DRAWN BY

16 N. Carroll Street Suite 610

Madison, WI

608.284.8225

OWNERS:

MARATHON COUNTY

500 FOREST STREET

WAUSAU, WI 54403

CONTACT: MICHAEL LOTTER

EMAIL:

PHONE: 715-261-6980

ARCHITECTS:

ANGUS YOUNG ASSOCIATES, INC.

555 SOUTH RIVER STREET

JANESVILLE, WI 53548

CONTACT: JIM TIBBETTS, AIA

EMAIL: [email protected]

PHONE: 608-756-2326

ARCHITECTS:

MKM ARCHITECTURE + DESIGN

119 W. WAYNE STREET

FORT WAYNE, IN 46802

CONTACT: DODD KATTMAN, AIA

EMAIL: [email protected]

PHONE: 260-422-0783

MECHANICAL, ELECTRICAL & PLUMBING:

RING & DUCHATEAU, LLP

17400 W. CAPITOL DRIVE

BROOKFIELD, WI  53045

CONTACT: JASON LAROSH

EMAIL: [email protected]

PHONE: 414-778-7430

STRUCTURAL & AQUATICS:

RAMAKER & ASSOCIATES, INC.

855 COMMUNITY DRIVE

SAUK CITY, WI 53583

CONTACT: ERIC KAUL

EMAIL: [email protected]

PHONE: 608-643-4100

[email protected]

Due to electronic distribution, this drawing may not be

printed to the scale indicated on the drawings. Do NOT

use scale to determine dimensions or sizes.

No part of this drawing may be used or reproduced in any

form or by any means, or stored in a database or retrieval

system, without prior written permission of.

ANGUS YOUNG ASSOCIATES, INC.

Copyright © 2018 All Rights Reserved

1.1/2"=1'-0"SCALE:

PARTITION TYPE

WALL CONSTRUCTION PER

STEEL STUD HEADER

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

PARTITION TYPE

WALL CONSTRUCTION PER

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

SIDES

CONTINUOUS SEALANT BOTH

SIDES

CONTINUOUS SEALANT BOTH

PER SIDE MINIMUM

3 JAMB ANCHORS

HOLLOW METAL FRAME

PROVIDE BATT INSULATION IN

JAMBS AT CONFERENCE ROOM

SCALE: 1 1/2"=1'-0"

PARTITION TYPE

WALL CONSTRUCTION PER

BACKER ROD AND SEALANT BOTH SIDES

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

PARTITION TYPE

WALL CONSTRUCTION PER

HOLLOW METAL FRAME GROUTED SOLID

CONTINUOUS SEALANT BOTH SIDES

GROUTED SOLID

HOLLOW METAL FRAME

(3) PER SIDE MINIMUM

MASONRY JAMB ANCHORS

BOND BEAM

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

SCALE: 1 1/2"=1'-0"

BOTH SIDES

CONTINUOUS SEALANT

3-ANCHORS PER JAMB

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE SEE

BRICK VENEER

SCALE: 1 1/2"=1'-0"

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

HOLLOW METAL FRAME GROUTED SOLID

BACKER ROD AND SEALANT BOTH SIDES

PARTITION TYPE

WALL CONSTRUCTION PER

GROUTED SOLID

HOLLOW METAL FRAME

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

CONTINUOUS SEALANT BOTH SIDES

PARTITION TYPE

WALL CONSTRUCTION PER

(3) PER SIDE MINIMUM

BOLT TYPE JAMB ANCHORS

SCALE: 1 1/2"=1'-0"

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

PARTITION TYPE

WALL CONSTRUCTION PER

GROUTED SOLID

HOLLOW METAL FRAME

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

CONTINUOUS SEALANT BOTH SIDES

PARTITION TYPE

WALL CONSTRUCTION PER

(3) PER SIDE MINIMUM

BOLT TYPE JAMB ANCHORS

GROUTED SOLID

HOLLOW METAL FRAME BOTH SIDES

BACKER ROD AND SEALANT

1/4" TEMPERED GLASS

SCALE: 1.1/2"=1'-0"

PARTITION TYPE

WALL CONSTRUCTION PER

STEEL STUD HEADER

PARTITION TYPE

WALL CONSTRUCTION PER

PARTITION TYPE

WALL CONSTRUCTION PER

CONTINUOUS SEALANT BOTH SIDES

1/4" TEMPERED GLASS

CONTINUOUS SEALANT BOTH SIDES

(3) JAMB ANCHORS PER SIDE MINIMUM

1/4" TEMPERED GLASS

CONTINUOUS SEALANT BOTH SIDES

FRAME PER SCHEDULE

FRAME PER SCHEDULE

FRAME PER SCHEDULE

SCALE: 1.1/2"=1'-0"

SC

HE

DU

LE

SE

E D

OO

R

SEALANT EACH SIDE

CONTINUOUS PERIMETER

DOOR PER SCHEDULE

WALL TYPES SCHEDULE

WALL CONSTRUCTION PER

SEALANT EACH SIDE

CONTINUOUS PERIMETER

MINIMUM

(3) ANCHORS PER JAMB

HOLLOW METAL FRAME

SWING DIRECTION PER PLAN

DOOR PER SCHEDULE-

SHIM AS REQUIRED

HOLLOW METAL FRAME

SCALE: 1.1/2"=1'-0"

WALL SECTION

WALL CONSTRUCTION PER

EVERY 18" ABOVE DOOR

FLASHING WITH WEEP HOLES

CONTINUOUS PRE FINISHED METAL

BRICK BEYOND

STEEL ANGLE

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

WALL SECTION

WALL CONSTRUCTION PER

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

BOTH SIDES

BACKER ROD AND SEALANT

ALUMINUM FRAME

ALUMINUM FRAME

BOTH SIDES

BACKER ROD AND SEALANT

SIDE MINIMUM

3 JAMB ANCHORS PER

SCALE: 1.1/2"=1'-0"

WALL SECTION

WALL CONSTRUCTION PER

EVERY 18" ABOVE DOOR

FLASHING WITH WEEP HOLES

CONTINUOUS PRE FINISHED METAL

GROUTED SOLID

HOLLOW METAL FRAME

BRICK BEYOND

STEEL ANGLE

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

GROUTED SOLID

HOLLOW METAL FRAME

WALL SECTION

WALL CONSTRUCTION PER

BOTH SIDES

CONTINUOUS SEALANT

PLAN FOR SWING DIRECTION

DOOR PER SCHEDULE. SEE

BOTH SIDES

CONTINUOUS SEALANT

SIDE MINIMUM

3 JAMB ANCHORS PER

A301

DETAILS

SCHEDULES AND

ROOM FINISH, DOOR

A B C D E F

(DIRECTOR'S OFFICE)

INTERIOR WINDOW

FIXED ALUMINUM

EXTERIOR WINDOW

FIXED ALUMINUM

(PANEL STYLE E)

EXTERIOR WINDOW

FIXED ALUMINUM

(PANEL STYLE F)

EXTERIOR WINDOW

FIXED ALUMINUM

(STAFF CORRIDOR)

INTERIOR WINDOW

FIXED ALUMINUM

(CHARTING ROOM)

INTERIOR WINDOW

FIXED ALUMINUM

2"

2"

1

HOLLOW METAL

A B

FLUSH WOOD

C

W/FULL LITE

FLUSH WOODW/LITE

FLUSH WOOD

D

W/ FULL LT

WIDE STILE

ALUMINUM

E

HOLLOW METAL

INSULATED

2"

2

4"

W/4" HEAD

HOLLOW METAL

6"

2"2"

7

2"

PER PLAN

GLAZING

¼" TEMPERED

2"

3

4"

W/4" HEAD

HOLLOW METAL

4

2"

8"

G

(PUBLIC CORRIDOR)

WINDOW SYSTEM

ALUMINUM RIBBON

W/SIDE LITES

ALUMINUM

6 8

COORDINATE WITH DOOR SPECIFICATIONS

ALUMINUM W/SLIDING DOOR

DOOR SPECIFICATIONS

AND SIDE LITES. COORDINATE WITH

ALUMINUM W/SLIDING DOOR

COORDINATE WITH DOOR SPECIFICATIONS

ALUMINUM WITH SLIDING DOOR

2"

6"

6"

GLAZING

¼" TEMPERED

2"

2"2"

PER PLAN

5

AT VESTIBULE

ALUMINUM LITES

HEAD

JAMB

DETAILS AT METAL STUD WALL

INTERIOR METAL DOOR FRAME

JAMB

HEAD

HOLLOW METAL FRAME AT FURRED WALL

EXTERIOR CMU WALL @ MASONRY

JAMB DETAIL (HEAD IS SIMILAR)

DETAILS AT PRECAST WALL

INTERIOR METAL DOOR FRAME

HEAD

JAMB

DETAILS AT PRECAST WALL

INTERIOR METAL DOOR FRAME

HEAD

JAMB

DETAILS AT METAL STUD WALL

HEAD

JAMB

SILL

INTERIOR FIXED METAL WINDOW FRAME

TYPICAL INTERIOR DOOR DETAIL @ CMU WALL

HEAD

JAMB

HEAD

JAMB

DETAILS AT METAL STUD WALLEXTERIOR ALUMINUM DOOR FRAME

HEAD

JAMB

DETAILS AT METAL STUD WALLEXTERIOR HOLLOW METAL DOOR FRAME

FRAME TYPES

WINDOW TYPES

DOOR TYPES

21

A301

26

A301

27

A301

31

A301

32

A301

22

A301

28

A301

03

A301

04

A301