PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas...

96
D-KTC FLUID CONTROL S.r.l. PRODUCT CATALOGUE

Transcript of PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas...

Page 1: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

D-KTC FLUID CONTROL S.r.l.

PRODUCT CATALOGUE

Page 2: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 3: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Office:

Via Giovanni Pacini, 93

20131 MILANO (MI) – ITALY

TEL. +39 (0)2 70608573

FAX +39 (0)2 26688354

Factory/Warehouse:

Località Pradaglie

29013 CARPANETO PIACENTINO (PC) – ITALY

TEL. +39 (0)523 853038

FAX +39 (0)523 850833

Banks Information

Banks: INTESA SAN PAOLO MILANO - ITALY

CARIPARMA CARPANETO – ITALY

BNL CARPANETO – ITALY

BANCA POPOLARE DI MILANO GALLARATE – ITALY

Page 4: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

We would like to take this opportunity to introduce our company D-KTC Fluid Control: a complete

manufacturer of strainers, sight low indicators, sample coolers and special equipment that is been supplying

its products to Petrochemical , Chemical , Power , Nuclear and Onshore / Offshore industries worldwide since

its establishment in 1998.

D-KTC Fluid Control is a partner of ARMSTRONG INTERNATIONAL for steam/air traps, manifolds and steam /

air / hot water systems.

D-KTC Fluid Control is part of CHERO GROUP which includes CHERO PIPING for ittings and valve /

piping packages, thus giving us the advantage of being able to satisfy all of our customers piping project

requirements.

Our current manufacturing facilities - factory and workshop - are built over an area of 19.000 m2, out of which

5.000 m2 are covered (located in CARPANETO).

D-KTC Fluid Control is one of the very few companies worldwide who actually produces a complete range

of strainers and is therefore able to offer the best type and style of products / solutions to meet customers

speciications and applications.

Over the years D-KTC Fluid Control has developed an extensive range of pipeline ancillaries, Sight Flow

indicators , Sample Coolers, Conical , Y and Tee type Strainers , Bucket strainers and, thanks to our special

engineering division, strainers for special applications.

All items can be supplied in carbon steel and stainless steel and in most cases they are available in very short

delivery times directly from our stock.

Introduction

Page 5: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Customized materials are also available on request.

Manufacturing execution can be forged, cast or welded fabricated depending on the type and size.

D-KTC Fluid Control can supply strainers from ½” to 82” for ratings up to 4500 lbs.

Whenever additional ancillaries (especially for steam plants) are required, D-KTC Fluid Control is able to

complete the package supplying also all the other products manufactured within the CHERO GROUP, such

as ANSI Valves , ANSI Fittings , Ball Valves as well as Steam Separators, Condensate Recovery Pumps and

Vacuum Breakers.

D-KTC Fluid Control is a lexible and constantly developing company.

Within our technical department part of the staff is dedicated to research and development, to enable our

company to implement improvements or brand new products on a regular basis.

D-KTC Fluid Control’s quality, environment and safety systems are certiied according to ISO 9001, ISO 14001,

OHSAS 18001, PED 97/23/EC, TRCU 019/032 and ABSA.

Our quality assurance department is an independent body, ensuring that our quality assurance, environment

and safety procedures are respected and implemented throughout the entire cycle of the manufacturing

process.

We hope that you ind our range of products interesting. Should you require any further detail or additional

information concerning D-KTC Fluid Control, ARMSTRONG INTERNATIONAL or CHERO GROUP, please do not

hesitate to visit our website..... and to contact us at our premises, where we are at your complete disposal.

WWW.DKTCFLUIDCONTROL.COM

Page 6: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 6

Reference List

PRODUCTS

35 COUNTRIES

120 PROJECTS

32 YEARS OF EXPERIENCE

1250

Page 7: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 7

Tee Strainer

Flame Arrestors

• SONATRACH

Algeria

• EXXONMOBIL CHEMICALS

France

• Project PRIME G

France

• QATAR GAS LIQUEFIED GAS Co. (II)

Qatar

• GASCO RUWAIS

U.A.E.

• TOTAL Reinery of FEYZIN HDS 2nd Train

France

• Fos-Cavaou

France

• KHURSANIYAH GAS PLEIN

U.A.E.

• BRASKEM

Mexico

• ROTTERDAM NExBTL PLANT

The Netherlands

• SINGAPORE NExBTL PLANT

Singapore

• KURAIS

U.A.E.

• TERMINAL METHANIER

France

• KHARYAGA PHASE III - PROSERNAT

Russia

• CDU-4 PROJECT - MOHAMMEDIA

Morocco

• CNRL UPGRADING TRANCHE 2

Canada

• SAN NAZZARO PROJ. A128PM3177

Italy

• 3611 ARP KUWAIT (KW) EPC

Saudi Arabia

• QATAR LIQUIEFIED GAS Co.

Qatar

• ASTEXOL-2

Spain

• POTENZIAMENTO SVILUPPO VAL D’AGRI

DBN GAS FASE 2

Italy

• LUKOIL NEFTOKIN BURGAS

Bulgaria

• SAFCO V UREA STAND ALONE PROJECT

Saudi Arabia

• TULA-SALAMANCA

Italy

• BOROUGE III PROJECT - XH - MR -907

Italy

• LUKOIL NEFTOKIN BURGAS

Bulgaria

Page 8: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 8

Exhaust Heads

Sight Glasses

• GROUP LOTOS S.A.

Poland

• ULTRA LOW SULPHER DIESEL PROJECT

Saudi Arabia

• SAMIR UPGRADE PROJECT

Morocco

• GASCO

Abu Dhabi

• RLOC

Qatar

• NIJNI NOVGOROD INTEGRATED VINYLS PLANT

Russia

• SOBEGI’

France

• 9631 U-IKRA PROJECT

Russia

• IKRA PROJECT

Germany

• PROGETTO EST

Italy

• PMP PROJECT

Qatar

• SATAH FULL FIELD DEVELOPMENT

U.A.E.

• S.O.C. CMMP ICOEEP

Singapore

Page 9: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 9

Manifolds

Sample Panel

• GASCO

U.A.E.

• CEPSA

Spain

• LDPE/EVA TUBULAR REACTOR LINE

France

• Temparossa

Italy

• NSRP Proj

Vietnam

• 30606 (MHC UNIT) IPLOM

Italy

• PROJECT 30647 NYNAS SRU

Sweden

• SATORP

Saudi Arabia

• SATORP

Saudi Arabia

• LMG PROJECT

Poland

• NYNAS REFINERY

Norway

• Lukoil Neftokim Burgas

Bulgaria

• Braskem

Messico

• SATORP

Saudi Arabia

Page 10: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 10

Sample Coolers

• GASCO RUWAIS

U.A.E.

• GASCO RUWAIS

U.A.E.

• KHURSANIYAH GAS PLEIN

U.A.E.

• KHURSANIYAH GAS PLEIN

U.A.E.

• KURAIS

U.A.E.

• QATAR FERT.CO. QAFCO 5

Qatar

• AL-JUBAIL PROJ. 10009807

Saudi Arabia

• SOBEGI’

France

• LUKOIL NEFTOKIN BURGAS

Bulgaria

• DANGOTE

Nigeria

• Proj Nghi Son Thanh Hoa

Vietnam

Pot Strainers

• AL-JUBAIL PROJ.

Saudi Arabia

• BOROUGE III PROJECT - XH - MR -907

Italy

Page 11: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 11

Coalescer Filters

Steam Tramp

• ARZEW - LNG

Algeria

• QATAR FERT.CO. QAFCO 5

Qatar

• GASCO RUWAIS

U.A.E.

• DUNG QUAT REFINERY

Vietnam

• GROUP LOTOS S.A.

Poland

• ENGRO CHEMICAL PAKISTAN LTD

Pakistan

• 5229 RUWAIS THIRD NGL TRAIN

Abu Dhabi

• GDANSK REFINERY RESIDUE

Poland

• AL-JUBAIL

Saudi Arabia

• EAD ENDESA

Chile

• NESTE OIL

Netherlands

• SATORP

Saudi Arabia

• 2329-UPGRADING TRANCHE 2 PROJECT

Canada

• AIR LIQUID SINES

Portogallo

• D11 HEATER 101 REVAMPING PROJECT

Sweden

• CM02 PECEM

Brasile

• LMG PROJECT

Poland

• 2400-DCU EXPANSION

Canada

• SOBEGI’

France

• SULPHUR GRANULATION PLANT

Saudi Arabia

• 5229 RUWAIS TR-3

U.A.E.

Page 12: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 12

Conical Strainers

• TOTAL Reinery of FEYZIN HDS 2nd Train

France

• Fos-Cavaou

France

• SINGAPORE NExBTL PLANT

Singapore

• ROTTERDAM NExBTL PLANT

The Netherlands

Duplex

• LUKOIL NEFTOKIN BURGAS

Italy

• UTE Porto do PECEM

Brazil

• CDU-4 PROJECT - MOHAMMEDIA

Morocco

• ASTEXOL-2

Spain

• LUKOIL NEFTOKIN BURGAS

Bulgaria

• NYNAS REFINERY

Norway

• SAFCO V UREA STAND ALONE PROJECT

Saudi Arabia

• TULA-SALAMANCA

Italy

• BOROUGE III PROJECT - XH - MR -907

Italy

Page 13: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 13

Y Strainers

• EXXONMOBIL CHEMICALS

France

• GASCO RUWAIS

U.A.E.

• NIOC

Iran

• SONATRACH

Algeria

• KHURSANIYAH GAS PLEIN

U.A.E.

• Project PRIME G

France

• Ras Laffan Olein Project

Qatar

• KURAIS

U.A.E.

• REPSOL PETROLEO

Spagna

• DUNG QUAT REFINERY

Vietnam

• Fos-Cavaou LNG Terminal

France

• SAUDI KAYAN

U.A.E.

• SOGIF - FOS SUR MER

France

• RLOC

Qatar

• ROTTERDAM NExBTL PLANT

The Netherlands

• TECHNIP KTI Project

Poland

• OFFSHORE ASSOCIATED GASES EPC PACKAGE

U.A.E.

• UTE Porto do PECEM

Brazil

• JER PACKAGE 2A

Saudi Arabia

• LMG PROJECT

Poland

• KHARYAGA PHASE III - PROSERNAT

Russia

• BIOMASS POWER PLANT

Italy

• CNRL UPGRADING TRANCHE 2

Canada

• NYNAS PROJ. 30647/A0053

Norway

• ASTEXOL-2

Spain

• POTENZIAMENTO SVILUPPO VAL D’AGRI

DBN GAS FASE 2

Italy

• SHAH SULPHUR STATION AND PIPELINES

PROJECT

U.A.E.

• SAFCO V UREA STAND ALONE PROJECT

Saudi Arabia

• SONARA PROJECT

Cameroon

• CIUDEN PROJECT

Spain

• TULA-SALAMANCA

Italy

• ETHYDCO

Egypt

• BOROUGE III PROJECT - XH - MR -907

Italy

• ITALY to BAHRAIN

Sita Kingdom of Bahrain

Page 14: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

CERTIFICATIONS

Page 15: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 16: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 17: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 18: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 19: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 20: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

������������������

����� ������� ������������������

�����������������������������������������

�������������

�������������� ����������

�����

���������

���� ����­�������

��� ���������������������­�������������������������������������­���� ���������������������������� �� ��­­���� �����������������������������

�����

 �­���������

����� ���������������

��������� ��������� �������������

�������������

������ � ��

��������� �������������

�� ���� ����

���­������

����������������������

�������� � ������������ ������������������������­� �� ��������­������ ���

������������������������������������������������ ����������������������������������������������������������� ���­��������������������­�������

������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

��������­��­����������������� ��������������������������������� � �������������������­­������

������������������������ �����������������­����­���������������������������������������������������������������������������� �������­��

��� ����¡���� ��������

� �� ����

�����������

Page 21: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

������������������

Page 22: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 23: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 24: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 25: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Y Forged Strainer section includes two different types of strainers.

In the following sections you can visualize the characteristics of the desired strainer.

FORGED“Y” STRAINERS

Page 26: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 26

FORGED STEEL “Y”D-KTC

YSF800

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Y “ – strainers should never be installed in upward low condition.

Page 27: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 27

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A105N ASTM A182 F316

1.1 Flange ASTM A105N ASTM A182 F316

2 Screen SS 316 SS 316 X

3 Plug ASTM A105N ASTM A182 F316

4 Gasket 316 / GRAPHITE 316 / GRAPHITE X

5 Drain plug ASTM A105N ASTM A182 F316

6 Bolting ASTM A193 B7/A 194 2HASTM A320 L7/ASTM

A194 2Gr.4

POS.6 (BOLTED COVER) : F800 2” ONLYOTHER MATERIALS ON REQUEST

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

F800 –ANSI 800.

OTHER RATINGS ON REQUEST

CONNECTIONS

Screwed ANSI B1.20.1 (NPT) / BS21 (BSP)

Buttweld ASME B 16.25

Socket Welding ANSI B16.11

Flanged ANSI / UNI / DIN

HOW TO SERVICE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to be performed approximately once a month, is to blow off small impurities trough the drain-plug (5). It is recommended to install a drain valve on a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points here below: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken, bent or deformed screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

Flanged

Size (inches)

DRAIN PLUG S H H1 C Weight

(kg)

UNI-DINPN16-25-40

SF Kg

150#

SF Kg

300#

SF Kg

600#

SF Kg

¾” ¼” 90 60 85 41 1 - - - - - - - -

½” ¼” 90 60 85 41 1 150 2.6 165 2.3 165 2.8 165 3.2

¾” ¼” 110 75 100 46 1.2 170 4 191 3.2 191 4.3 191 4.7

1” ¼” 130 93 140 56 2 200 4.4 216 4.2 216 5.3 216 5.8

1½” ¼” 180 144 200 85 6 240 11 241 9.7 241 15 241 12.9

2” ½” 185 140 200 100 7 230 13 292 12 292 15 292 16.3

2.½” ½” 185 140 200 100 7 282 16 294 18 308 20

STANDARD PERFORATIONS 0.8mmSPECIAL PERFORATIONS ON REQUESTDimensions : S, H , H1 , C , SF are in millimeters (mm)

8

Page 28: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 28

YSF1500

FORGED STEEL “Y”D-KTC

WRONGWRONG CORRECTCORRECT

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Y “ – strainers should never be installed in upward low condition.

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

Page 29: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 29

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A105N ASTM A182 F316

1.1 Flange ASTM A105N ASTM A182 F316

2 Screen SS 316 SS 316 X

3 Plug ASTM A105N ASTM A182 F316

4 Gasket 316 / GRAPHITE 316 / GRAPHITE X

5 Drain plug ASTM A105N ASTM A182 F316

6 Bolting ASTM A193 B7/A 194 2HASTM A320 L7/ASTM

A194 2Gr.4

POS.6 (BOLTED COVER) : F1500 ½” ONLYOTHER MATERIALS ON REQUEST

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

F1500 – ANSI 1500.

CONNECTIONS

Screwed ANSI B1.20.1 (NPT) / BS21 (BSP)

Buttweld ASME B 16.25

Socket Welding ANSI B16.11

Flanged ANSI / UNI / DIN

Flanged

Size (inches) DRAIN PLUG S H H1 C Weight(kg)

1500#SF Kg

1/2” 1/

4” 110 75 100 46 1.4 216 5.5

3/4” 1/

4” 130 93 140 56 2.2 229 7

1” 1/4” 180 144 200 85 6.2 254 13

11/2” 1/

2” 185 140 200 100 7.5 305 19

STANDARD PERFORATIONS 0.8mmSPECIAL PERFORATIONS ON REQUESTDimension : S, H , H1 , C , SF are in millimeters (mm)

HOW TO SERVICE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is reccomanded to install a drain valve on a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken, bent or deformed screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

Page 30: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 31: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Y Cast Strainer section includes twenty different types of strainers.

In the following tabs you can visualize the table of the desired strainer.

CAST

“Y” STRAINERS

Page 32: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 32

YSC150

CAST STEEL “Y”D-KTC

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

1

1

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

Page 33: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 33

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C150 – ANSI 150.

OTHER RATING ON REQUEST

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Bonnet ASTM A105 Astm A182 F316

3 Screen SS 316 SS 316 X

4 Gasket SS 316 / Graph. SS 316 / Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7

6 Nuts ASTM A194 2H ASTM A194 Gr.4

7 Drain Plug ASTM A105 ASTM A182 F316

OTHER MATERIALS ON REQUEST

Size (inches) ½ ¾ 1 1.½ 2” 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”

S(RF) [mm] 108 117 127 165 203 241 292 406 495 622 699 788 914 978 978 1295

S[mm] 108 117 127 165 203 241 292 406 495 622 699 788 914 978 978 1295

H[mm] 67 73 87 120 140 210 270 360 460 570 700 770 870 975 1095 1300

H1[mm] 180 210 240 270 190 260 340 400 580 660 800 1200 1400 1530 1750 2040

Weight [kg] 6 9 11 20 14 26 40 68 140 190 270 350 640 700 895 1370

STANDARD PERFORATIONS: 1.5 mmSPECIAL PERFORATIONS ON REQUESTDRAIN PLUG: ¾” NPT

2

2

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

Page 34: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 34

YSC300

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

4

4

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

CAST STEEL “Y”D-KTC

Page 35: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 35

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C300 – ANSI 300.

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Bonnet ASTM A105 Astm A182 F316

3 Screen SS 316 SS 316 X

4 Gasket SS 316 / Graph. SS 316 / Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7

6 Nuts ASTM A194 2H ASTM A194 Gr.4

7 Drain Plug ASTM A105 ASTM A182 F316

OTHER MATERIALS ON REQUEST

5

5

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

Size (inches) ½” ¾” 1” 1.½” 2” 3” 4” 6” 8” 10” 12” 14” 16” 18” 20” 24”

S (RF) [mm] 152 178 203 229 267 318 356 445 559 622 711 838 864 978 1061 1346

S[mm] 152 178 203 229 267 318 356 445 559 622 711 838 864 978 1061 1346

H[mm] 70 80 115 128 175 240 330 380 500 625 740 805 920 1025 1140 1360

H1[mm] 150 170 240 260 250 275 360 470 575 920 1100 1200 1360 1350 1700 2050

Weight [kg] 6 9 11 20 20 45 65 105 180 254 430 670 750 863 1125 1625

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUESTDRAIN PLUG: ¾” NPT

Page 36: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 36

YSC600

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

7

7

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

CAST STEEL “Y”D-KTC

Page 37: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 37

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C600 – ANSI 600

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Bonnet ASTM A105 Astm A182 F316

3 Screen SS 316 SS 316 X

4 Gasket SS 316 / Graph. SS 316 / Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7

6 Nuts ASTM A194 2H ASTM A194 Gr.4

7 Drain Plug ASTM A105 ASTM A182 F316

OTHER MATERIALS ON REQUEST

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

Size(inches) ½” ¾” 1” 1.½” 2” 3” 4” 6” 8” 10” 12” 14” 16”

S (RTJ) [mm] 165 191 203 216 295 259 435 562 663 790 841 892 994

S(RF)[mm] 165 191 203 216 292 356 432 559 660 787 838 889 991

S[mm] 165 191 203 216 292 356 432 559 660 787 838 889 991

H[mm] 120 140 115 170 193 260 310 400 500 600 720 865 991

H1[mm] 180 210 240 240 270 320 400 530 650 790 1200 1420 1520

Weight [kg] 6 9 11 11 35 60 95 230 400 590 700 770 1140

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUESTDRAIN PLUG: ¾” NPT

Page 38: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 38

YSC900

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

10

10

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

CAST STEEL “Y”D-KTC

Page 39: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 39

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C600 – ANSI 600

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

11

Size(inches) ½” ¾” 1” 1.½” 2” 3” 4” 6” 8” 10” 12” 14” 16”

S (RTJ) [mm] 165 191 203 216 295 259 435 562 663 790 841 892 994

S(RF)[mm] 165 191 203 216 292 356 432 559 660 787 838 889 991

S[mm] 165 191 203 216 292 356 432 559 660 787 838 889 991

H[mm] 120 140 115 170 193 260 310 400 500 600 720 865 991

H1[mm] 180 210 240 240 270 320 400 530 650 790 1200 1420 1520

Weight [kg] 6 9 11 11 35 60 95 230 400 590 700 770 1140

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUESTDRAIN PLUG: ¾” NPT

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Screen S.S. 304 S.S. 316 X

3 Cover ASTM A105 ASTM A240 316

4 Gasket RJ ARMCO F316 X

5 Drain Plug ASTM A105 AISI 316

6 Studs ASTM A193 B7 ASTM A320 L7

7 Nuts ASTM A194 2H ASTM A194 Gr.4

OTHER MATERIALS ON REQUEST

Page 40: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 40

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

13

13

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

YSC1500

CAST STEEL “Y”D-KTC

Page 41: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 41

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C1500 – ANSI 1500

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Screen S.S. 304 S.S. 316 X

3 Cover ASTM A105 ASTM A240 316

4 Gasket RJ ARMCO F316 X

5 Drain Plug ASTM A105 AISI 316

6 Studs ASTM A193 B7 ASTM A320 L7

7 Nuts ASTM A194 2H ASTM A194 Gr.4

OTHER MATERIALS ON REQUEST

14

Size(inches) 2” 3” 4” 6” 8”

S (RTJ)[mm] 371 473 549 711.5 842

S(RF)[mm] 368 470 546 705 832

S[mm] 368 470 546 705 832

H[mm] 250 325 375 480 620

H1[mm] 400 540 600 750 900

Weight[kg] 60 100 160 400 600

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUEST DRAIN PLUG: 3⁄4” NPT

Page 42: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 42

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

16

16

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

YSC1500 Pressure Seal

CAST STEEL “Y”D-KTC

Page 43: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 43

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C1500 – ANSI 1500

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

17

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Bonnet ASTM A105 Astm A182 F316

3 Screen SS 304 SS 316 X

4 Gasket SS 304 A182 F316 X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7

6 Nuts ASTM A194 2H A194 Gr.4

7 Drain Plug A105 S.S. 316

8 Disk Joint ASTM A105 A182 F316

9 Retain ring ASTM A182 F6 A182 F6

10 Ring ASTM A182 F6 A182 F6

OTHER MATERIALS ON REQUEST

Size(inches) 10” 12” 14” 16”

S(RTJ) [mm] 1000 1146 1276 1407

S(RF) [mm] 991 1130 1257 1384

S [mm] 864 991 1067 1194

H [mm] 700 800 970 1150

H1 [mm] 1100 1300 1500 1700

Weight [kg] 1200 1500 2320 2750

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUEST DRAIN PLUG: 3⁄4” NPT

Page 44: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 44

Designed according to ANSI B16.34 strainer bodies are

produced with a higher wall thickness to increase corrosion

allowance.

Standard stainers are equipped with screens for the average

service of most luids (steam, gas, air, oil, chemicals, ect.).

A large screen open area ensures an eficent iltering action

with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different peforation (or wire mesh) and

materials can be manufactured on request.

WRONGWRONG CORRECTCORRECT

22

22

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

YSC2500 Pressure Seal

CAST STEEL “Y”D-KTC

Page 45: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 45

LIMITING CONDITIONS YSF800 (according to ISO 6552 ):

According to the body rating (ANSI B 16.34)

C1500 – ANSI 1500

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Remove cover (3) and gasket (4). 3- Remove screen (2) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. Never reinstall a broken or distorted screen. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (2). Be sure to center the screen in the upper seat. 7- Put cover in place (3). Be sure that drain plug (5) is closed. 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

CONNECTIONS

Buttweld ASME B 16.25

Flanged ASME B 16.5

SIZE

6”- 8”- 10”- 12”

14”- 16”

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB Astm A351 CF8M

2 Bonnet ASTM A105 Astm A182 F316

3 Screen SS 304 SS 316 X

4 Gasket SS 304 A182 F316 X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7

6 Nuts ASTM A194 2H A194 Gr.4

7 Drain Plug A105 S.S. 316

8 Disk Joint ASTM A105 A182 F316

9 Retain ring ASTM A182 F6 A182 F6

10 Ring ASTM A182 F6 A182 F6

OTHER MATERIALS ON REQUEST

Size (inches) 6” 8” 10” 12” 14”

S(RTJ) [mm] 927 1038 1292 1444 -

S [mm] 610 762 914 1041 1118

H [mm] 580 570 750 800 820

H1 [mm] 820 850 1100 1200 1250

Weight [kg] - - - - -

STANDARD PERFORATIONS: 1.5 mm SPECIAL PERFORATIONS ON REQUEST DRAIN PLUG: 3⁄4” NPT

23

Page 46: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 47: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Tee Strainer section includes seven different types of strainers.

In the following tabs you can visualize the table of the desired strainer.

“Tee” STRAINERS

Page 48: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 48

Strainer maintenace should be made at least once year,

or whenever the pressure drop is found to be in Designed

according to ANSI B16.34 strainer bodies are produced with a

higher wall thickness to increase corrosion allowance.

Standard stainers are equipped with screens for the average

service of most gases & luids (steam, gas, air, oil, chemicals,

ect.). A large screen open area ensures an eficent iltering

action with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different perforation (or wire mesh) and

materials can be manufactured on request it is possible to

manufacture screens.

WRONGWRONG CORRECTCORRECT

TS150

“Tee” STRAINERD-KTC

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Tee “ – strainers should never be installed in upward low condition. (see above)

Page 49: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 49

CONNECTIONS

Buttweld ANSI B16.25

Flanged ANSI B16.5

(Not for TS2500 - CLAMPED)

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A234 WPB ASTM A420 WPL6ASTM WP 403

F316ASTM A234 WP5

1.2 Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

1.3 Guide rods S.S. 304 S.S. 304 S.S. 304 S.S. 304

2 Blind lange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

3 *Basket S.S. 304 S.S. 304 S.S. 304 S.S. 304 X

4 Gasket SS316/Graph. SS316/Graph. SS316/Graph. SS316/Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 ASTM A193 B7

6 Nuts ASTM A194 2H ASTM A194 Gr.4 ASTM A194 Gr.4 ASTM A194 2H

7 Plug ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

OTHER MATERIALS ON REQUEST* BASKET TYPE: V - W - WW - Z. Basket coniguration depend of % ratio requested by customer

Size (inches) 2” 3” 4” 6” 8” 10” 12” 16” 18” 20” 24” 26”

S 127 172 210 286 356 432 508 610 686 762 864 990

SF 254 312 363 464 560 636 737 864 966 1052 1169 1235

H 148 182 208 260 311 351 403 472 525 571 635 688

Dimension : SF , S , H are in millimeters ( mm)

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

V Type W Type WW Type Z Type

Page 50: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 50

Strainer maintenace should be made at least once year,

or whenever the pressure drop is found to be in Designed

according to ANSI B16.34 strainer bodies are produced with a

higher wall thickness to increase corrosion allowance.

Standard stainers are equipped with screens for the average

service of most gases & luids (steam, gas, air, oil, chemicals,

ect.). A large screen open area ensures an eficent iltering

action with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different perforation (or wire mesh) and

materials can be manufactured on request it is possible to

manufacture screens.

WRONGWRONG CORRECTCORRECT

TS300

“Tee” STRAINERD-KTC

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Tee “ – strainers should never be installed in upward low condition. (see above)

Page 51: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 51

CONNECTIONS

Buttweld ANSI B16.25

Flanged ANSI B16.5

(Not for TS2500 - CLAMPED)

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A234 WPB ASTM A420 WPL6ASTM WP 403

F316ASTM A234 WP5

1.2 Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

1.3 Guide rods S.S. 304 S.S. 304 S.S. 304 S.S. 304

2 Blind lange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

3 *Basket S.S. 304 S.S. 304 S.S. 304 S.S. 304 X

4 Gasket SS316/Graph. SS316/Graph. SS316/Graph. SS316/Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 ASTM A193 B7

6 Nuts ASTM A194 2H ASTM A194 Gr.4 ASTM A194 Gr.4 ASTM A194 2H

7 Plug ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

OTHER MATERIALS ON REQUEST* BASKET TYPE: V - W - WW - Z. Basket coniguration depend of % ratio requested by customer

Size (inches) 2” 3” 4” 6” 8” 10” 12” 16” 18” 20” 24”

S 127 172 210 286 356 432 508 610 686 762 864

SF 268 332 382 483 579 668 769 903 1004 1086 1201

H 158 197 225 281 333 385 438 511 565 609 673

Dimension : SF , S , H are in millimeters ( mm)

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

V Type W Type WW Type Z Type

Page 52: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 52

Strainer maintenace should be made at least once year,

or whenever the pressure drop is found to be in Designed

according to ANSI B16.34 strainer bodies are produced with a

higher wall thickness to increase corrosion allowance.

Standard stainers are equipped with screens for the average

service of most gases & luids (steam, gas, air, oil, chemicals,

ect.). A large screen open area ensures an eficent iltering

action with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different perforation (or wire mesh) and

materials can be manufactured on request it is possible to

manufacture screens.

WRONGWRONG CORRECTCORRECT

TS600

“Tee” STRAINERD-KTC

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Tee “ – strainers should never be installed in upward low condition. (see above)

Page 53: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 53

CONNECTIONS

Buttweld ANSI B16.25

Flanged ANSI B16.5

(Not for TS2500 - CLAMPED)

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A234 WPB ASTM A420 WPL6ASTM WP 403

F316ASTM A234 WP5

1.2 Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

1.3 Guide rods S.S. 304 S.S. 304 S.S. 304 S.S. 304

2 Blind lange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

3 *Basket S.S. 304 S.S. 304 S.S. 304 S.S. 304 X

4 Gasket SS316/Graph. SS316/Graph. SS316/Graph. SS316/Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 ASTM A193 B7

6 Nuts ASTM A194 2H ASTM A194 Gr.4 ASTM A194 Gr.4 ASTM A194 2H

7 Plug ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

OTHER MATERIALS ON REQUEST* BASKET TYPE: V - W - WW - Z. Basket coniguration depend of % ratio requested by customer

Size (inches) 2” 3” 4” 6” 8” 10” 12” 16” 18” 20” 24”

S 127 172 210 286 356 432 508 610 686 762 864

SF 286 351 427 535 636 750 833 979 1067 1156 1284

H 177 216 260 324 382 492 574 624 676 753 673

Dimension : SF , S , H are in millimeters ( mm)

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

V Type W Type WW Type Z Type

Page 54: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 54

Strainer maintenace should be made at least once year,

or whenever the pressure drop is found to be in Designed

according to ANSI B16.34 strainer bodies are produced with a

higher wall thickness to increase corrosion allowance.

Standard stainers are equipped with screens for the average

service of most gases & luids (steam, gas, air, oil, chemicals,

ect.). A large screen open area ensures an eficent iltering

action with a low pressure drop.

Filtering area to inlet area ratio is higher than 3 to 1.

Screens area is manufactured with perforated plate in the

materials and with the perforation speciied in the relevant

tables. Screens with different perforation (or wire mesh) and

materials can be manufactured on request it is possible to

manufacture screens.

WRONGWRONG CORRECTCORRECT

TS900

“Tee” STRAINERD-KTC

All strainers should be mounted as close as possible to the valve or machinery they are installed to

protect. It is important to ensure that the strainer is installed with the low following the same direction

of the low direction arrow cast on the strainer body.

In horizontal or inclined pipelines, ensure that the screen housing is always mounted below the pipeline.

In vertical pipelines “ Tee “ – strainers should never be installed in upward low condition. (see above)

Page 55: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 55

CONNECTIONS

Buttweld ANSI B16.25

Flanged ANSI B16.5

(Not for TS2500 - CLAMPED)

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A234 WPB ASTM A420 WPL6ASTM WP 403

F316ASTM A234 WP5

1.2 Flange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

1.3 Guide rods S.S. 304 S.S. 304 S.S. 304 S.S. 304

2 Blind lange ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

3 *Basket S.S. 304 S.S. 304 S.S. 304 S.S. 304 X

4 Gasket SS316/Graph. SS316/Graph. SS316/Graph. SS316/Graph. X

5 Stud Bolts ASTM A193 B7 ASTM A320 L7 ASTM A320 L7 ASTM A193 B7

6 Nuts ASTM A194 2H ASTM A194 Gr.4 ASTM A194 Gr.4 ASTM A194 2H

7 Plug ASTM A105 ASTM A350 LF2 ASTM A182 F316 ASTM A182 F5

OTHER MATERIALS ON REQUEST* BASKET TYPE: V - W - WW - Z. Basket coniguration depend of % ratio requested by customer

Size (inches) 2” 3” 4” 6” 8” 10” 12” 16” 18” 20” 24”

S 127 172 210 286 356 432 508 610 686 762 864

SF 343 389 453 579 694 813 922 1056 1157 1271 1462

H 219 242 279 353 419 485 549 626 689 752 879

Dimension : SF , S , H are in millimeters ( mm)

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

V Type W Type WW Type Z Type

Page 56: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 57: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Pot Strainer section includes six different types of strainers divided in two series.

In the following tabs you can visualize the table of the desired strainer.

“Pot” STRAINERS

Page 58: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 58

D-KTC Pot strainers have been speciically designed to meet all

customer requirements including high pressure applications.

Designed and fabricated according to ASME VIII Div.1 as

standard version, they can also be supplied according to other

pressure vessel regulations. I.e. ASME B31.3 etc.

Standard features include low pressure drops at high velocities,

stainless steel perforated baskets, vents and drains with the

possibility to supply davit lifts, quick open closures, DP gauges.

We are also able to manufacture customer requests following.

PSW150

“Pot” STRAINERD-KTC

Page 59: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 59

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS NOTE

1 Body ASTM A106

2 Cover ASTM A105

3 Gasket 316 / GRAPHITE

4 Studs ASTM A193 B7

5 Nuts ASTM A194 2H

5 Drain plug ASTM A105N

6

Screen Stainless Steel

Perf. Plate Stainless Steel

Mesh Stainless Steel

7 Drain ASTM A105 Plugged ¾” NPT

8 Vent ASTM A105 Plugged ¾” NPT

9* Lifting eyes Carbon Steel For cover only

10 Legs Carbon Steel On request

* Davit on request

Size(inches) 1½” 2” 3” 4” 5” 6” 8” 10” 12” 14” 16” 18” 20” 24”

S (mm) 356 356 381 406 406 508 559 13 889 940 1067 1067 1092 1219

B (mm) 305 305 318 356 381 432 533 635 711 838 914 991 1118 1524

C (mm) 163 178 203 210 241 241 279 330 368 400 464 464 553 553

D (mm) 168 168 168 219 273 273 324 406 457 508 610 610 762 762

Kg 40.0 43.1 46.7 77.1 104.3 108.9 154.2 272.2 349.3 440.0 616.9 635.0 870.9 997.9

NOTES : Inlet / Outlet langes are according to ANSI B16.5

Page 60: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 60

D-KTC Pot strainers have been speciically designed to meet all

customer requirements including high pressure applications.

Designed and fabricated according to ASME VIII Div.1 as

standard version, they can also be supplied according to other

pressure vessel codes. I.e. ASME B31.3 etc.

Standard features include low pressure drops at high velocities,

stainless steel perforated baskets, vents and drains with the

possibility to supply davit lifts, quick open closures, DP gauges.

We are also able to manufacture customer requests following.

PSW300

“Pot” STRAINERD-KTC

Page 61: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 61

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS NOTE

1 Body ASTM A106

2 Cover ASTM A105

3 Gasket 316 / GRAPHITE

4 Studs ASTM A193 B7

5 Nuts ASTM A194 2H

5 Drain plug ASTM A105N

6

Screen Stainless Steel

Perf. Plate Stainless Steel

Mesh Stainless Steel

7 Drain ASTM A105 Plugged ¾” NPT

8 Vent ASTM A105 Plugged ¾” NPT

9* Lifting eyes Carbon Steel For cover only

10 Legs Carbon Steel On request

* Davit on request

Size(inches) 1½” 2” 3” 4” 5” 6” 8” 10” 12” 14” 16” 18” 20” 24”

S (mm) 356 356 381 406 445 553 584 838 914 965 1092 1092 1130 1264

B (mm) 305 305 318 356 381 432 533 635 711 838 914 991 1118 1524

C (mm) 229 229 229 241 279 279 318 368 406 445 508 508 610 610

D (mm) 168 168 168 219 273 273 324 406 457 508 610 610 762 762

Kg 69.2 72.6 79.4 131.5 181.4 192.8 274.4 464.9 603.3 757.5 1059.1 1115.8 1537.7 1780.4

NOTES : Inlet / Outlet langes are according to ANSI B16.5

Page 62: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 62

D-KTC Pot strainers have been speciically designed to meet all

customer requirements including high pressure applications.

Designed and fabricated according to ASME VIII Div.1 as

standard version, they can also be supplied according to other

pressure vessel codes. I.e. ASME B31.3 etc.

Standard features include low pressure drops at high velocities,

stainless steel perforated baskets, vents and drains with the

possibility to supply davit lifts, quick open closures, DP gauges.

We are also able to manufacture customer requests following.

PSW900

“Pot” STRAINERD-KTC

Page 63: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 63

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS NOTE

1 Body ASTM A106

2 Cover ASTM A105

3 Gasket 316 / GRAPHITE

4 Studs ASTM A193 B7

5 Nuts ASTM A194 2H

5 Drain plug ASTM A105N

6

Screen Stainless Steel

Perf. Plate Stainless Steel

Mesh Stainless Steel

7 Drain ASTM A105 Plugged ¾” NPT

8 Vent ASTM A105 Plugged ¾” NPT

9* Lifting eyes Carbon Steel For cover only

10 Legs Carbon Steel

* Davit on request

Size(inches) 20”

S (mm) 1410

B (mm) 1525

C (mm) 1064

D (mm) 762

Kg 6621

NOTES : Inlet / Outlet langes are according to ANSI B16.5

Page 64: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 64

D-KTC Pot strainers have been speciically designed to

meet all customer requirements including for high pressure

applications. Designed and fabricated to ASME VIII Div.1 as

standard but can also be supplied to other pressure vessel

codes. I.e. ASME B31.3 etc.

Standard features include low pressure drops at high velocities,

stainless steel perforated baskets as standard, vents and drains

with the possibility to supply davit lifts, quick open closures,

DP gauges. We are also able to manufacture against customer

requests in all types of materials.

PSC150/300/600

“Pot” STRAINERD-KTC

Page 65: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 65

MAINTENANCE

Strainer maintenace should be made at least once a year, or whenever the pressure drop is higher than normal igures. A quick clean-up system, to perform approximately once a month, is to blow off small impurities trough the drain-plug (5). It is raccomanded to install a drain valve by a nipple to the drain hole to speed-up this operation. For a complete maintenance follow the points herebelow: 1- Be sure that the main line has been shut off. 2- Untighten cover stud bolts (5) and nuts (6) and remove cover [blind flange] (2) and gasket (4). 3- Remove basket (3) and carefully inspect it for damages. If any hole in the screen is clogged up, clean it with compressed air and / or any suitable tool. If the screen is broken in any part or out of shape, replace it with a new spare one. 4- Carefully clean the inside of the strainer body. 5- Fit a new gasket (4). 6- Install the new screen or the cleaned one (3). 7- Put cover in place (2). 8- Slowly give pressure to the line, checking for leakages. 9- Write on the strainer body the date of this maintenance operation.

POS. DESCRIPTION MATERIALS SPARE

1 Body ASTM A216 WCB ASTM A351 CF8(M)

2 Screen SS304 SS304/SS316 X

3 Gasket SW 316/Graphite SW 316/Graphite X

4 Cover ASTM A105N ASTM A182 F304/316

5 Bolts ASTM A193 B7 ASTM A193 B8

6 Nuts ASTM A194 2H ASTM A194 Gr.8

7/8 Drain/Vent ASTM A105N

9* Lifting eyes: on request

* Davit on request

POT STRAINER PSC150Size

(inches) 2” 3” 4” 6” 8” 10” 12” 14” 16”

h1 (mm) 110 140 160 180 240 315 350 395 430

h (mm) 207 265 350 500 650 850 950 1245 800

l (mm) 290 350 420 550 700 850 950 1150 1100

Kg 36 47 60 170 290 400 535 920 950

NOTES : Inlet / Outlet langes are according to ANSI B16.5

POT STRAINER PSC300Size (inches) 2” 3” 4” 6” 8” 10”

h1 (mm) 110 140 160 180 240 315

h (mm) 205 265 350 500 650 850

l (mm) 309 350 420 550 725 850

Kg 38 49 65 178 299 415

NOTES : Inlet / Outlet langes are according to ANSI B16.5

POT STRAINER PSC600Size (inches) 14”

h1 (mm) 395

h (mm) 1245

l (mm) 1250

Kg 950

NOTES : Inlet / Outlet langes are according to ANSI B16.5

Page 66: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 67: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Temporary Conical Strainer section includes three different types of strainers.

In the following tabs you can visualize the table of the desired strainer.

“Conical Temporary”STRAINERS

Page 68: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 68

Conical type temporary strainers are designed for the eficent

removal of solids in new pipeline startup services. They are

compact and rugged and can be installed either vertically

or horizontally. They can be manufactured using any kind of

wire mesh or perforated plate, in carbon and stainless steel or

customized alloys. Given dimensions are for reference purpose

only. It is possible to manufacture conical strainers in line with

any customer standard. Strainers are designed to be installed

between ANSI B16.5 langes and FF, RF and RTJ facings.

FT1

CONICAL STRAINERD-KTC

ASSEMBLY INSTRUCTIONS

Insert the strainer between the two langes ( 4 )Make sure the two gasket are itted on both sidesTighten bolts ( 3 ) keeping the strainer ( 1 ) + gaskets ( 2 ) in the correct position

MAINTENANCE INSTRUCTIONS

Unscrew bolts ( 3 )Remove the strainer ( 1 ) and clean or replace itWhen re-assembling use new gaskets

Strainers may be manufactured to any customerʼs standard.

Strainers may be manufactured to any customerʼs standard.

Page 69: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 69

HOW TO ORDER:

i.e. FT1 4” 150# A240 TP304 - PERF. HOLS 3 mm DIAi.e. FT2 4” 150# A240 TP304 - PERF. HOLS 3 mm DIAi.e. FT3 4” 150# A240 TP304 - 3 MESH FILTRATION

POS. DESCRIPTION MATERIALS SPARES

1 Ring SS 304

2 Perforated plate ASTM A240 304

OTHER MATERIALS ON REQUEST

Size (inches) 1½” 2” 3” 4” 6” 8” 10” 12" 14” 16” 18” 20” 24”

D 73 92 127 157 216 270 324 81 412 470 534 584 692

H 60 80 120 150 230 300 350 400 450 500 550 600 650

L 70 70 70 80 100 100 110 110 120 130 130 140 150

C 20 20 20 20 20 20 20 20 20 20 20 20 20

S 3 3 3 3 5 5 5 5 5 7 7 7 7

A 33 48 75 100 150 200 250 300 332 383 434 485 587

B 20 26 44 60 89 118 149 175 194 224 250 285 300

Dimension : D, H, L, C, S , A, B are in millimeters ( mm)OTHER SIZES ON REQUEST

Page 70: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 70

Strainers may be manufactured to any customerʼs standard.

Conical type temporary strainers are designed for the eficent

removal of solids in new pipeline startup services. They are

compact and rugged and can be installed either vertically

or horizontally. They can be manufactured using any kind of

wire mesh or perforated plate, in carbon and stainless steel

or exotic alloys. Given dimensions are for reference purpose

only. It is possible to manufacture conical strainers in line with

any customer standard. Strainers are designed to be installed

between ANSI B16.5 langes and meet FF, RF and RTJ facings.

FT2

CONICAL STRAINERD-KTC

ASSEMBLY INSTRUCTIONS

Insert the strainer between the two langes ( 4 )Make sure the two gasket are itted on both sidesTighten bolts ( 3 ) keeping the strainer ( 1 ) + gaskets ( 2 ) in the correct position

MAINTENANCE INSTRUCTIONS

Unscrew bolts ( 3 )Remove the strainer ( 1 ) and clean or replace itWhen re-assembling use new gaskets

Strainers may be manufactured to any customerʼs standard.

Page 71: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 71

HOW TO ORDER:

i.e. FT2 4” 150# A240 TP304 - PERF. HOLS 3 mm DIA

POS. DESCRIPTION MATERIALS SPARES

1 Ring SS 304

2 Perforated plate ASTM A240 304

OTHER MATERIALS ON REQUEST

Size (inches) 1½” 2” 3” 4” 6” 8” 10” 12" 14” 16” 18” 20” 24”

D 73 92 127 157 216 270 324 81 412 470 534 584 692

H 60 80 120 150 230 300 350 400 450 500 550 600 650

L 70 70 70 80 100 100 110 110 120 130 130 140 150

C 20 20 20 20 20 20 20 20 20 20 20 20 20

S 3 3 3 3 5 5 5 5 5 7 7 7 7

A 33 48 75 100 150 200 250 300 332 383 434 485 587

B 20 26 44 60 89 118 149 175 194 224 250 285 300

Dimension : D, H, L, C, S, A, B are in millimeters ( mm)OTHER SIZES ON REQUEST

Page 72: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 72

Strainers may be manufactured to any customerʼs standard.

Conical type temporary strainers are designed for the eficent

removal of solids in new pipeline startup services. They are

compact and rugged and can be installed either vertically

or horizontally. They can be manufactured using any kind of

wire mesh or perforated plate, in carbon and stainless steel

or exotic alloys. Given dimensions are for reference purpose

only. It is possible to manufacture conical strainers in line with

any customer standard. Strainers are designed to be installed

between ANSI B16.5 langes and meet FF, RF and RTJ facings.

FT3

CONICAL STRAINERD-KTC

ASSEMBLY INSTRUCTIONS

Insert the strainer between the two langes ( 4 )Make sure the two gasket are itted on both sidesTighten bolts ( 3 ) keeping the strainer ( 1 ) + gaskets ( 2 ) in the correct position

MAINTENANCE INSTRUCTIONS

Unscrew bolts ( 3 )Remove the strainer ( 1 ) and clean or replace itWhen re-assembling use new gaskets

Strainers may be manufactured to any customerʼs standard.

Page 73: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 73

HOW TO ORDER:

i.e. FT3 4” 150# A240 TP304 - 3 MESH FILTRATION

POS. DESCRIPTION MATERIALS SPARES

1 Ring SS 304

2 Wire mesh SS 304

3 Rods SS 304

OTHER MATERIALS ON REQUEST

Size (inches) 1½” 2” 3” 4” 6” 8” 10” 12" 14” 16” 18” 20” 24”

D 73 92 127 157 216 270 324 81 412 470 534 584 692

H 60 80 120 150 230 300 350 400 450 500 550 600 650

L 70 70 70 80 100 100 110 110 120 130 130 140 150

C 20 20 20 20 20 20 20 20 20 20 20 20 20

S 3 3 3 3 5 5 5 5 5 7 7 7 7

A 33 48 75 100 150 200 250 300 332 383 434 485 587

B 20 26 44 60 89 118 149 175 194 224 250 285 300

Dimension : D, H, L, C, S, A, B are in millimeters ( mm)OTHER SIZES ON REQUEST

Page 74: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 75: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

Our Forged Flow Indicator section includes three different types of valve.

In the following tabs you can visualize the table of the desired valve.

“Flow” INDICATORS

Page 76: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 76

300 A105/300 F316/SF 300

FORGED STEEL FLOW INDICATORSD-KTC

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

CONNECTIONS

crewed ANSI B1.20.1 NPT - BS21 BSP

Socket weld ANSI B16.11

Flanged ANSI B16.5 150#/300#/ UNI / DIN / PN 16/25/40

LIMITING CONDITIONS

Acc. to the body rating ANSI 300 ( B 16.34 )

GLASS CONDITION TEMPERED

DN ½” – ¾” 1” 1½”

Norm. work temp. 130°C 130°C 130°C

Max. work temp. (for 300 h ) 150°C 150°C 150°C

Termic shock 120°C 120°C 120°C

Max. pressure ( bar ) 50 50 24

GLASS CONDITION BOROSILICATE

DN ½” – ¾” 1” 1½”

Norm. work temp. 280°C 280°C 280°C

Max. work temp. (for 300 h ) 300°C 300°C 300°C

Termic shock 265°C 265°C 265°C

Max. pressure ( bar ) 50 50 24

Size S H D C Weight (Kg) (SF) ANSIUNI-DIN

½” 90 84 40 12 1.3 130

¾” 90 84 40 12 1.3 150

1” 110 94 50 12 2.3 160

1½” 127 114 70 12 3.5 200

Page 77: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 77

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

CLASS SF 300

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A105 ASTM A182 F316

2 Flange ASTM A105 ASTM A182 F316

3 Glass TEMPERED TEMPERED X

4 Gasket CAF CAF X

5 Bolt ASTM A193 B7 ASTM A193 B8

6 Flange ASTM A105 ASTM A182 F316

7 Flange WN ASTM A105 ASTM A182 F316

Indicator See type(3) Borosilicate acc. to DIN7080 , on request (4) C.A.F. : Compressed Aramidic Fibre

CLASS 300 A105

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A105

2 Flange ASTM A105

3 Glass TEMPERED X

4 Gasket CAF X

5 Stud Bolts ASTM A193 B7

6 Nuts ASTM A194 2H

7 Flange ASTM A105

(3) Borosilicate acc. to DIN7080 (4) C.A.F.: Compressed Aramidic Fibre

CLASS 300 F316

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A182 F316

2 Flange ASTM A182 F316

3 Glass TEMPERED X

4 Gasket CAF X

5 Stud Bolts ASTM A320 L7

6 Nuts ASTM A194 Gr.4

7 Flange ASTM A182 F316

(3) Borosilicate acc. to DIN7080 , on request (4) C.A.F. : Compressed Aramidic Fibre

Page 78: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 78

SC 150

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

TEMPERED GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

BOROSILICATE GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

204 43 25 25 11 7

280 40 25 25 11 7

Page 79: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 79

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 15 20 25 25 25

Weight (Kg) 10.5 20 26.5 68 125

(SF) ANSI-UNI-DIN 230 310 350 480 600

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB ASTM A351 CF8M

2 Flange ASTM A216 WCB ASTM A351 CF8M

3 Glass TEMPERED TEMPERED X

4 Gasket CAF CAF X

5 Stud Bolts ASTM A193 B7 ASTM A193 B8

6 Nuts ASTM A194 2H ASTM A194 Gr.8

7IndicatorSee type

ON REQUEST ON REQUEST

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

Page 80: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 80

SC 300

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

TEMPERED GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

BOROSILICATE GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

204 43 25 25 11 7

280 40 25 25 11 7

Page 81: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 81

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB ASTM A351 CF3M

2 Flange ASTM A105 ASTM A182 F316L

3 Glass ON REQUEST ON REQUEST X

4 Gasket CAF CAF X

5 Bolt ASTM A193 B7 ASTM A193 B8

6 Nuts ASTM A194 2H ASTM A194 Gr.8

7IndicatorSee type

BY CUSTOMER BY CUSTOMER

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 20 20 25 25 25

Weight (Kg) 230 310 350 480 600

(SF) ANSI-UNI-DIN 10.5 20 26.5 68 125

Page 82: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 82

S150 CF3M

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

Acc. to the body rating DIN PN 25 up to 4” – DIN PN16 for 6”- 8”GLASS CONDITION

MAX. WORK TEMPERATURE

Tempered glass 180°C

Borosilicate glass 300°C

150 45

204 43

280 40

Page 83: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 83

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A351 CF3M

2 Flange ASTM A182 F316L

3 Glass BOROSILICATE X

4 Gasket GRAPHITE X

5 Stud Bolts ASTM A193 B8

6 Nuts ASTM A194 GR.8

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 15 20 25 25 25

Weight (Kg) 10.5 20 26.5 68 125

(SF) ANSI-UNI-DIN 230 310 350 480 600

Page 84: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 84

S150 CF8M

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

Acc. to the body rating DIN PN 25 up to 4” – DIN PN16 for 6”- 8”GLASS CONDITION

MAX. WORK TEMPERATURE

Tempered glass 180°C

Borosilicate glass 300°C

150 45

204 43

280 40

Page 85: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 85

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 15 20 25 25 25

Weight (Kg) 10.5 20 26.5 68 125

(SF) ANSI-UNI-DIN 230 310 350 480 600

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A351 CF8M

2 Flange ASTM A351 CF8M

3 Glass TEMPERED X

4 Gasket CAF X

5 Stud Bolts ASTM A193 B8

6 Nuts ASTM A194 Gr.8

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

Page 86: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 86

S150 WCB

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

Acc. to the body rating DIN PN 25 up to 4” – DIN PN16 for 6”- 8”GLASS CONDITION

MAX. WORK TEMPERATURE

Tempered glass 180°C

Borosilicate glass 300°C

150 45

204 43

280 40

Page 87: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 87

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 15 20 25 25 25

Weight (Kg) 10.5 20 26.5 68 125

(SF) ANSI-UNI-DIN 230 310 350 480 600

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A351 CF8M

2 Flange ASTM A351 CF8M

3 Glass TEMPERED X

4 Gasket CAF X

5 Stud Bolts ASTM A193 B8

6 Nuts ASTM A194 Gr.8

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

Page 88: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 88

S300 WCB

CAST STEEL FLOW INDICATORSD-KTC

CONNECTIONS

Flanged ANSI B16.5

150#/300# / UNI / DIN / PN 16/25/40

INDICATOR TYPE - Pos. 7

TYPE- A -

NO INDICATOR

TYPE- B -

FIXED FLAPPERS

TYPE- C -

CHAIN

TYPE- D -

FLOATING BALL

TYPE- E -

SPINNER

TYPE- F -

PIPE

LIMITING CONDITIONS

TEMPERED GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

BOROSILICATE GLASS acc. to DIN 7080

SIZE BODY RATING2”

3003”

3004”

3006”

3008”

300

Temp (°C) Max working pressure (bar)

-40 / +37 50 25 25 11 7

93 46 25 25 11 7

150 45 25 25 11 7

204 43 25 25 11 7

280 40 25 25 11 7

Page 89: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 89

MAINTENANCE:

Maintenance of low indicators should be made whenever the visibility through the window is poor. Follow the points here below:Make sure that the main line is shutoff. Loosen bolts (5) and remove covers (2), glasses (3) and the four gaskets. Clean the inside of the body to remove any dirt. Clean the two glasses with a soft cloth using if necessary a suitable cleaning luid. If glasses are damaged or cracked, replace them. Reassemble all the elements replacing the four gaskets. Slowly give pressure to the line checking for leaks.

POS. DESCRIPTION MATERIALS SPARES

1 Body ASTM A216 WCB

2 Flange ASTM A216

3 Glass BOROSILICATE X

4 Gasket CAF X

5 Bolt ASTM A193 B7

6 Indicator -

(3) Borosilicate acc. to DIN7080 , on request(4) C.A.F. : Compressed Aramidic Fibre

Size (inches) 2” 3” 4” 6” 8”

D 80 110 135 200 250

C 20 20 25 25 25

Weight (Kg) 230 310 350 480 600

(SF) ANSI-UNI-DIN 10.5 20 26.5 68 125

Page 90: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 91: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

FLAME ARRESTOR

Page 92: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 92

During the tank iling, the breathing valve expel over the tank

some gas that could burn. The tank has to be protected to

avoid that the lames spread inside the tank. This is the reason

why a lame stopper is installed between the tank and the

breathing valve and it has to:

- Defeat the lame

- Resist and make the hot fade away

- Resist to the shock wave producer by an external explosion.

The lame arrestor eficirncy is reduced by the lame arrestot

element and by the ilth that is inside it.

FLAME ARRESTORD-KTC

TECHNICAL DATA

Design codes EN.16852, ASME VIII, IX

Design pressure 10 BarG

Design temperature-10/+250 °C for C.S.-120/+250 for S.S.

InstallationIn-line delagration,

vertical, bidirectional, max distance from ire source DNx50

Max operating temperature 60 °C

MESG IIA

Atex certiicated EX G-IIA

Ped certiicated CE1370

Factory tested Dimensional, hydrotest at 19.38 BarG

sizes From 1” to 12”

Connections Flanged ANSI 150# RF

External protection 00-GA-E-60701

Page 93: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

This document is property of D-KTC S.r.l. - Sales Office: Via Pacini, 93 - 20131 - Milano, Italy - 02/70608573 - [email protected]

Factory: Loc.Pradaglie - 29013 Carpaneto P.no (PC) - Tel. 0523 853038/859997 93

POS. DESCRIPTION MATERIALS

1 Body C.S SS304L SS316L C.S.

2 Housing SS316L SS304L SS316L C.S.

3 Elements SS316L SS316L SS316L SS316L

4 Gaskets A.F.F. SS/PTFE S.S./PTFE A.F.F.

5 Bolts B7/2H B8-8 B8M-8M B7/2H

6 Label SS304 SS304 SS304 SS304

Product codes with ANSI langes 422.2.xx.101 422.2.xx.103 422.2.xx.105 422.2.xx.109

Size (mm) A B H Weight (KG)

1” 200 200 250 15

2” 230 230 333 27

3” 280 280 422 43

4” 345 345 440 80

5” 407 407 500 100

6” 483 483 580 135

8” 597 597 897 220

10” 699 699 1211 250

12” 813 813 1233 360

Product code With Ansi langs 422.2.08.103

Neoprene® Viton® Telon® Kalrez® are DuPont’sTM trademarks. DuPont is a trademark of DuPont and its afiliates

Page 94: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 95: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas
Page 96: PRODUCT CATALOGUE - D-KTC Fluid Control · 2018-06-22 · cnrl upgrading tranche 2 canada nynas proj. 30647/a0053 norway astexol-2 spain potenziamento sviluppo val d’agri dbn gas

D-KTC FLUID CONTROL S.r.l.