DAIKIN General Catalogue 2012

366
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende ALL SEASONS °CLIMATE COMFORT ECPEN12-500_P2 • 1000 • 11/10 • Copyright Daikin The present publication supersedes ECPEN11-500_P2 Printed in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environment is set in the EMAS and ISO 14001 systems. Responsible editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin products are distributed by: q.,9.7H9&st BENEFITS AIR TREATMENT REMOTE CONTROL & TIMER OTHER FUNCTIONS Photocatalytic deodorising filter Removes airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses, microbes, this to ensure a steady supply of clean air. Flash streamer The Flash Streamer generates high-speed electrons that powerfully break down odours and formaldehyde Air filter Removes airborne dust particles to ensure a steady supply of clean air. Titanium photocatalytic air purification filter Removes airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses, microbes, this to ensure a steady supply of clean air Timer Allows to preset the air conditioner to start/stop at a specified time. Twin/triple/double twin application 2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All indoor units operate within the same mode (cooling or heating) from one remote control. Weekly timer Timer can be set to start heating or cooling anytime on a daily or weekly basis Auto-restart The unit restarts automatically at the original settings after power failure. Wired remote control Wired remote control to start, stop and regulate the air conditioner from a distance. VRV® for residential application Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. Multi tenant The indoor unit’s main power supply can be turned off when leaving the hotel or office building. 24 Hour timer Timer can be set to start cooling/heating anytime during a 24-hour period. Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies. Infrared remote control Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance. Multi model application Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode. Centralised control Centralised control to start, stop and regulate several air conditioners from one central point. Drain pump kit Facilitates condensation draining from the indoor unit. Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent- certification.com or using: www.certiflash.com 2012 General Catalogue GENERAL CATALOGUE 2012 Commercial Industrial Residential Know the TRUE COLOURS of your energy bill... ...and prepare for a monumental change. Seasonal efficiency is a new energy efficiency measure that will be the standard as of y 2013. A true monumental change. Products optimised for seasonal eciency consume less energy and put less burden on the environment. And on your wallet. At Daikin we already go seasonal today. That is why we are the first in the industry to launch products optimized for seasonal efficiency. The seasonal performance values of our products. Energy efficiency is no longer a blind spot. Find out more on www.daikin.eu PRELIMINARY 2 EPC__12-500_OM.indd 1 1-12-2011 9:47:12

description

DAIKIN General Catalogue 2012

Transcript of DAIKIN General Catalogue 2012

Page 1: DAIKIN General Catalogue 2012

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

ALL SEASONS °CLIMATE COMFORT

ECP

EN1

2-5

00

_P

2 •

10

00

• 1

1/1

0 •

Co

pyr

igh

t D

aiki

n

The

pre

sen

t p

ub

licat

ion

su

pe

rse

de

s EC

PEN

11

-50

0_

P2

Prin

ted

in B

elg

ium

by

Lan

no

o (w

ww

.lan

no

op

rin

t.be)

, a c

om

pan

y w

ho

se c

on

cern

fo

r th

e en

viro

nm

ent

is s

et in

th

e EM

AS

and

ISO

140

01 s

yste

ms.

Res

po

nsi

ble

ed

ito

r: D

aiki

n E

uro

pe

N.V

., Z

and

voo

rde

stra

at 3

00

, B-8

40

0 O

ost

en

de

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

Daikin products are distributed by:

BENEFITSAIR TREATMENT

REMOTE CONTROL & TIMER

OTHER FUNCTIONS

Photocatalytic deodorising fi lter

Removes airborne dust particles, decomposes odours and restrains the reproduction

of bacteria, viruses, microbes, this to ensure a steady supply of clean air.

Flash streamer

The Flash Streamer generates high-speed electrons that powerfully break down

odours and formaldehyde

Air fi lter

Removes airborne dust particles to ensure a steady supply of clean air.

Titanium photocatalytic air purifi cation fi lter

Removes airborne dust particles, decomposes odours and restrains the reproduction

of bacteria, viruses, microbes, this to ensure a steady supply of clean air

Timer

Allows to preset the air conditioner to start/stop at a specifi ed time.

Twin/triple/double twin application

2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have

diff erent capacities. All indoor units operate within the same mode (cooling or

heating) from one remote control.

Weekly timer

Timer can be set to start heating or cooling anytime on a daily or weekly basis

Auto-restart

The unit restarts automatically at the original settings after power failure.

Wired remote control

Wired remote control to start, stop and regulate the air conditioner from a distance.

VRV® for residential application

Up to 9 indoor units (even diff erent capacities and up to 71 class) can be connected

to a single outdoor unit. All indoor units can individually be operated within the same

mode.

Multi tenant

The indoor unit’s main power supply can be turned off when leaving the hotel or

offi ce building.

24 Hour timer

Timer can be set to start cooling/heating anytime during a 24-hour period.

Self-diagnosis

Simplifi es maintenance by indicating system faults or operating anomalies.

Infrared remote control

Infrared remote control with LCD to start, stop and regulate the air conditioner from

a distance.

Multi model application

Up to 5 indoor units (even diff erent capacities) can be connected to a single outdoor

unit. All indoor units can individually be operated within the same mode.

Centralised control

Centralised control to start, stop and regulate several air conditioners from one

central point.

Drain pump kit

Facilitates condensation draining from the indoor unit.

Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com

2012General

Catalogue

GE

NE

RA

L C

AT

AL

OG

UE

20

12

Commercial

Industrial

Residential

Know the TRUE COLOURS of your energy bill......and prepare for a monumental change.

Seasonal effi ciency is a new energy effi ciency measure that will be the standard as of y

2013. A true monumental change. Products optimised for seasonal effi ciency consume less

energy and put less burden on the environment. And on your wallet. At Daikin we already go

seasonal today. That is why we are the fi rst in the industry to launch products optimized for

seasonal effi ciency. The seasonal performance values of our products.

Energy effi ciency is no longer a blind spot. Find out more on www.daikin.eu

PRELIMINARY 2

EPC__12-500_OM.indd 1 1-12-2011 9:47:12

user
ντρο
Page 2: DAIKIN General Catalogue 2012

2 area intelligent eye

Air fl ow is sent to a zone other than where the person is located at that moment.

If two people are detected in the room, the air fl ow is projected away from the

occupants.

If no people are detected, the unit will automatically switch over to the energy-

effi cient setting.

Energy effi ciency

Daikin air conditioners are energy effi cient and economical (full range A class energy

label).

Seasonal effi ciency

Seasonal effi ciency gives a more realistic indication on how effi cient air conditioners

operate over an entire heating or cooling season.

Energy saving during operation standby

Current consumption is reduced by about 80 % when operating on standby. If no

people are detected for more than 20 minutes, the system will automatically switch

to the current-saving mode.

Night set mode

Saves energy, by preventing overcooling or overheating during night time.

Econo mode

This function decreases the power consumption so that other applicances that need

large power consumption can be used. This function is also energy saving.

Movement sensor

The sensor detects whether someone is in the room. When the room is empty, the

unit switches to economy mode after 20 minutes and restarts when a person enters

the room.

Inverter technology

In combination with inverter controlled outdoor unitsHome leave operation

During absence, the indoor temperature can be maintained at a certain level.

Fan only

The air conditioner can be used as fan, blowing air without cooling or heating.

Free cooling

By exploiting the low external air temperatures to cool the water, free cooling

reduces the load on the compressors and decreases considerably the annual

operating costs during the cold season.

Powerful mode

If the temperature in the room is too high/low, it can be cooled down/heated quickly

by selecting the ‘powerful mode’. After the powerful mode is turned off , the unit

returns to the preset mode.

Comfort mode

The new fl ap changes the discharge angle horizontally for cooling operation and

downward vertically for heating operation. This in order to prevent cold or warm air

from blowing directly on the body.

Whisper quiet

Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to

disturb the quiet of the neighbourhood.

Outdoor unit silent operation

Lowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet

environment for the neighbourhood.

Comfortable sleeping mode

Increased comfort function that follows a specifi c temperature fl uctuation rhythm.

Radiant heatThe front panel of the indoor unit radiates additional heat to add to your comfort

on cold days

Draught prevention

When starting to warm up or when the thermostat is off , the air discharge direction is

set horizontally and the fan to low speed, to prevent draught. After warming up, air

discharge and fan speed are set as desired.

Auto cooling-heating changeover

Automatically selects cooling or heating mode to achieve the set temperature

(heat pump types only).

Indoor unit silent operation

Lowers the operation sound of the indoor unit by 3dB(A). This function is useful when

studying or sleeping.

Night quiet mode (cooling only)

Lowers the operation sound of the outdoor unit automatically by 3dB(A) by

removing a jumper wire on the outdoor unit. This function can be deactivated if the

jumper wire is reinstalled on the outdoor unit.

Double thermostat function

Controls the temperature via a sensor on the air conditioner or via a sensor on the

remote control.

Horizontal auto swing

Possibility to select automatic horizontal moving of the air discharge louvre, for

uniform air fl ow and temperature distribution.

Ceiling soiling prevention

A special function prevents air blowing out too long in horizontal position, to prevent

ceiling stains.

Auto fan speed

Automatically selects the necessary fan speed to reach or maintain the set

temperature.

3-D Air fl ow

This function combines Vertical and Horizontal auto-swing to circulate a stream of

cool/warm air right to the corners of even large spaces.

Vertical auto swing

Possibility to select automatic vertical moving of the air discharge louvre, for uniform air fl ow and temperature distribution.

Fan speed steps

Allows to select up to the given number of fan speed.

Dry programme

Allows humidity levels to be reduced without variations in room temperature.

Ururu - humidifi cation

Moisture is absorbed from the outdoor air and evenly distributed throughout the indoor areas.

Sarara - dehumidifi cation

Reduces indoor humidity, without aff ecting the room temperature, by mixing cool, dry air with warm air.

BENEFITSWE CARE ICONS

COMFORT

AIR FLOW

HUMIDITY CONTROL

Make your world a better place

Our mission, and the essence of our existence, is to identify and realise our customers’ future needs and dreams, even those that

they themselves may not yet be aware of. We can accomplish this goal by paying careful attention to changes in social trends and

conducting extensive marketing to win the hearts and minds of customers. It is essential that we offer customers optimum convenience and comfort that are always one step ahead of our competitors by providing customers with the highest

quality products, materials, and services for which we, as a manufacturer, will be absolutely responsible. Moreover, we will continue

offering products and services that provide customers with fresh excitement and continued enjoyment.

In any era in any business field, a company can grow and develop only if it possesses world-leading technologies.

As we continue developing our business operations in various fields, it is our mission to proactively develop initiatives to

respond to environmental issues. Incorporating environmental initiatives throughout our management must be a priority for us.

In all aspects of our business operations, including product development, manufacturing and sales, we need to formulate initiatives

that sustain and improve the environment. Meanwhile, we need to promote the development of new products and the innovation

of technologies that will lead to a more environmentally healthy world.

HE

AT

ING

AP

PL

IED

SY

ST

EM

S

AIR

CO

ND

ITIO

NIN

G

RE

FR

IGE

RA

TIO

N

EPC__12-500_OM.indd 2 1-12-2011 9:47:17

Page 3: DAIKIN General Catalogue 2012

TABLE OF CONTENTSTable of contents 1

New products 2012 2

Make your world a better place 6

Environmental awareness 7

Seasonal effi ciency 8

Daikin solutions to R-22 phase out 9

Air purifi er 10

Air conditioning

Residential applications 61

Pair applications 67

Multi model applications 82

Light commercial applications

Sky Air 129

Pair applications 136

Commercial multi system 160

Twin, triple, double twin applications 162

Rooftop 172

Medium to large commercial applications

VRV 175

VRV outdoor units 180

VRV indoor units 192

Hot water 218

Powerful selection programmes 221

Ventilation & Biddle Air Curtains 223

Marine Types 235

Heating

Air to water heat pumps 16

Daikin Altherma low temperature 20

Daikin Altherma high temperature 34

Daikin Altherma Flex Type 40

Daikin heat pump convector 46

Applied systems

Chillers 240

Air cooled chillers 244

Air cooled condensing units 279

Water cooled chillers 281

Condenserless chillers 291

Water cooled centrifugal chillers 295

Fan coil units 301

Air handling units 314

Refrigeration

Conveni-pack 320

ZEAS condensing units 324

Commercial condensing units 326

Large variable capacity condensing unit 327

Control systems, options &

accessories

Control systems 329

Options & accessories 345

� This symbol represents seaonal efficiency.It will be used throughout this catalogue to indicate where seasonal efficiency is already implemented in our product ranges.For more detailed information, please refer to page 8 and page 118.

GC_pre2_lowres.pdf 1 30/11/2011 12:30:19

Page 4: DAIKIN General Catalogue 2012

131

134

144

71

10

NEW RANGE OF WALL MOUNTED UNITS, DEVELOPED FOR SMALL OR WELL-INSULATED ROOMS - FTXS-K / CTXS-K

> Integrating design: high quality fi nishing

> Goes almost unnoticed in operation

> Top performance: full class A energy label

> Right dimensioning for optimum comfort

3-PORT 40 MULTI OUTDOOR UNITS - 3MXS40K

> The new 15 class responds to the new capacity requirements of the smallest rooms in the house and allows optimal distribution of capacity of new 3-port 40 multi outdoor unit

DAIKIN LEADS THE WAY TOWARDS SEASONAL EFFICIENCY!

> Introducing a complete light commercial range optimised for seasonal effi ciency!

OUTDOOR UNITS, OPTIMISED FOR SEASONAL EFFICIENCY - RZQG-L AND RZQSG-L

� Seasonal smart range � Already complies with the EU’s 2014 EcoDesign requirements � Available in 1 phase and 3 phase � All Sky Air indoor units can be used in combination with these

outdoor units

� Seasonal classic range � Available in 1 phase and 3 phase

NEXT GENERATION ROUND FLOW CASSETTES – FCQHG-F AND FCQG-F

> Optimised for seasonal effi ciency

> Even more energy effi cient with the new presence sensor

> Off ering improved comfort with the new fl oor sensor

> Flexibility: one or more fl aps can be easily closed when refurbishing the interior of your shop, offi ce …

LARGE CONCEALED CEILING UNIT – FDQ-C

> Optimised for seasonal effi ciency

> New casing

> Standard drain pump

> Easy installation:

� Less duct calculation � Air fl ow can be adjusted during installation via wired remote control

New products 2012

STREAMER TECHNOLOGY AIR PURIFIER - MC70LVM

> Stylish design

> Improved performance

> Unprecedented comfort

> Super quiet operation

> Easy to maintain

> Portable

> No installation

GC_pre2_lowres.pdf 2 30/11/2011 12:30:44

Page 5: DAIKIN General Catalogue 2012

175

152

174

146

211

NEW VRV IV OUTDOOR UNIT, INDOOR UNIT & CONTROL*

> Personalize your VRV to achieve the highest possible seasonal effi ciency and comfort

> Perfect heating comfort thanks to continuous heating during defrost on heat pump and heat recovery

> New round fl ow cassette setting the standard for comfort & effi ciency

> Simplifi ed commissioning and maintenance

Available: 2nd half 2012

*preliminary

VRV Heat Pump - RYCQ-A*

> For smaller products with basic cooling and heating requirements

> Connectable to all VRV indoor units, controls & ventilation

Available: 2nd half 2012

*preliminary

1.5 KW INDOOR UNITS FOR VRV, EXTENSION WITH 15 CLASS WALL MOUNTED

> Units especially developed for small or well-insulated rooms, such as hotel bedrooms, small offi ces, …

> Available as wall mounted unit (FXAQ), 4-way blow cassette (FXZQ) and concealed ceiling unit (FXDQ-P7)

WALL MOUNTED UNIT – FAQ-C

> Optimised for seasonal effi ciency

> New casing

> Extended with a 125 class

TALL FLOOR STANDING UNIT – FVQ-C

> Optimised for seasonal effi ciency

> New casing

> Better air fl ow distribution

> Air blown “up and down” for less variation in temperature

PR

ELIM

INA

RY

PR

ELIM

INA

RY

GC_pre2_lowres.pdf 3 30/11/2011 12:30:45

Page 6: DAIKIN General Catalogue 2012

268

266

247

288

312

FREE COOLING CHILLER - EWAD-CF

> Air cooled chiller with free cooling system

> High effi ciency version, combinable with 3 sound levels

> 11 sizes from 600 kW up to 1,565 kW

> Greater energy savings and reduced CO2 emissions during cold

season

LARGE AIR COOLED INVERTER CHILLER - EWAD-CZ

> Highest partial load effi ciency scores in its class (ESEER up to 5.8)

> Large operating range (ambient temperatures from -18°C up to +50°C)

> Multiple sound levels to meet accoustic requirements

> Highest cooling capacity in its class (up to 1,800 kW)

> Extensive option list including fan speed regulation, rapid restart and heat recovery option

D-AHU PROFESSIONAL AND D-AHU EASY

> Air fl ow rates from 500 m³/h up to 124,000 m³/h

> From standard sizes to customized solutions

> Premium Eurovent performances

> Infi nitely variable sizes

NEW FLOODED CHILLER RANGE - EWWD-H-

> 11 sizes between 370 and 1,215 kW

> Condenser leaving water up to 50°C as standard

> High temperature kit for condenser leaving water up to 65°C

> Extended with heat pump option

New products 2012

SMALL INVERTER CHILLER - EWA/YQ-BA*

> Air cooled chiller with inverter compressor and fan

> High effi ciency with leader-of-class ESEER up to 4.75

> Available both in cooling only and heat pump models

> Wide capacity range from 17 kW up to 75 kW (7 sizes)

> Supplied optionally with factory mounted (standard/high-ESP) pump

> R-410A scroll compressor (1 or 2 circuits)

GC_pre2_lowres.pdf 4 30/11/2011 12:30:45

Page 7: DAIKIN General Catalogue 2012

330

339

341

INDIVIDUAL CONTROL SYSTEMS

USER FRIENDLY REMOTE CONTROL WITH

CONTEMPORARY DESIGN – BRC1E52

> Optimise your system effi ciency via energy saving functions

> Temperature range limit saves energy by avoiding excessive heating or cooling

> kWh indication keeps track of your consumption

> Schedule timer with holiday setting, 3 diff erent weekly timers and improved setback function

ONLINE CONTROLLER - ALWAYS IN CONTROL,

NO MATTER WHERE YOU ARE

> Control solution to monitor and control the main functions of the residential indoor units.

> End-user friendly operation

> Can be used from any location via your smartphone, laptop, PC, tablet or touch screen

> Optimal home comfort/holiday home surveillance

> Flexible offi ce solution

RTD - UNIVERSAL CONTROL

> Indoor unit control via 0~10 volt, dry contact or resistance control

> Hotel controller with key card connection & window contact

> Duty/standby & alarm signal for IT application

> Heating interlock

OPEN PROTOCOL INTERFACES

INTERFACE

> Integratin of Split, Sky Air, and VRV indoor units in HA/BMS systems

> Allows monitoring and control of several devices from one central controller.

RTD - UNIVERSAL CONTROL

> Modbus interface

> Integration of Sky Air, VRV and ventilation units in BMS systems

OPTIONS & ACCESSORIES

WIRELESS ROOM TEMPERATURE SENSOR

> Flexible and easy installation

> Contemporary design

> Plug & play connection to VRV and Sky Air

GC_pre2_lowres.pdf 5 30/11/2011 12:30:45

Page 8: DAIKIN General Catalogue 2012

C02

-20% +20% -20%

Environmental awareness

What this really meansIn simple terms, the EU’s targets are aimed at reducing the amount of energy consumed, reducing the use of fossil and other natural

mineral fuels used in the production of energy, and the reduction of the amount of greenhouse gases (particularly CO2 and water

vapour) produced. And if we are to be successful in doing this, then new regulations, production and performance standards, and

energy usage rules will be needed.

The EU has not been slow in recognizing this need. New directives have been developed and issued on the subject of

� energy labelling of domestic appliances – this must show the true energy usage of equipment across the whole

year: for air-conditioning equipment this includes the introduction of a Seasonal Energy Efficiency Rating (SEER and SCOP)

� energy efficiency in buildings to reduce their impact on the environment through improved insulation, improved

heating and lighting systems and the increased use of renewable energy sources

� environmental performance of products throughout their life-cycle by the systematic integration of environmental

aspects at a very early stage in the product design

�� fluorinated greenhouse gases (F-gas) and ozone depleting substances which aim to phase out certain

refrigerants and tighten up on the checks needed to ensure that such gases are not being leaked into the atmosphere and

contributing to the greenhouse effect.

CO2 EMISSIONS

vs. 1990

Share of

RENEWABLE ENERGY

PRIMARY ENERGY USE

vs. BAU*

By the year

2020*Business As Usual

European Union’s 20-20-20 energy targetsIn March 2007, after years of worldwide concern, the European heads of state endorsed “an integrated approach to climate

and energy policy that aims to combat climate change and increase the EU’s energy security while strengthening

its competitiveness. They committed Europe to transforming itself into a highly energy-efficient, low carbon economy.”

(http://ec.europa.eu) To turn this into a reality, a series of challenging climate and energy objectives were set and became known as

the 20-20-20 energy targets, which are to be met by 2020 and these are:

GC_pre2_lowres.pdf 6 30/11/2011 12:30:45

Page 9: DAIKIN General Catalogue 2012

The Daikin Response

The way forwardAll in all, the European Union’s climate concerns have added a new urgency to our ongoing innovation and R&D – we are confident of

our response and that it will deliver huge benefits to the customers in terms of more controllable solutions giving perfect comfort, reduced

operating costs and a much lower ecological impact.

Environmental awareness

Quick start

Temperature remains stable

Temperature / Power input

Time

Set temp. Heat pump or air conditioner with Inverter

Heat pump or air conditioner without

Inverter

AEROTHERMAL HEAT PUMP HYDROTHERMAL HEAT PUMP GEOTHERMAL HEAT PUMP

Daikin, always the leader in air conditioning technology,

has embraced the challenges of the EU 20-20-20 declaration and

Energy Efficiency Directives and has moved positively to take a

market leadership position on many issues.

Many years ago, we developed the inverter technology that

is now installed in all of our air conditioning units. The inverter

system supplies full load power at start up but then monitors the

actual heating or cooling demand and steadily reduces the power

being used until the correct temperature is reach. It then effectively

turns itself off until a change is noted at which point it applies

sufficient power to bring the temperature back to the set point.

This direct link between temperature control and energy usage

means that inverter driven air conditioners are up to 30% more

energy efficiency. The eco-design requirements are very ambitious

and will in the end ban non-inverter technology.

Seasonal efficiency Over the years we have been concerned about letting our

clients know the true seasonal energy efficiency of our products,

as the rating system then in place was misleading. Our vision

on this has been vindicated and the introduction of seasonal

performance will ensure a better understanding of the

energy usage of all air conditioning systems. We have been

designing and engineering our equipment to achieve market-

leading SEERs and SCOPs and thus contributing to a reduction

of energy used.

Heat pump technologyIn many ways, it is with our advanced heat pump technology

and heat recovery systems that we can do most to

contribute towards the EU’s climate targets. Our use of heat

pumps to extract heat from the ambient air (a renewable heat source referred to as aerothermal energy) is very well

established and helps reduce the energy usage of whole

buildings. In addition, however, heat pumps can be used to

extract heat from the ground (geothermal energy) as

well as rivers, lakes and ground water (hydrothermal energy).

This renewable heat energy is then transferred to the refrigerant

system to raise the temperature of the outflow water and thus

effectively pre-heat it. This reduces the energy required to

provide heating and the transferred heat is often enough to

maintain domestic hot water tanks at the correct temperature.

This remarkable technology will now be applied to small

capacity units as we focus on total climate control in all its forms.

State-of-the-art control systems Our systems are all connected to advanced control systems that give

room-by-room settings as well as integrated building control to

ensure that the customer can maximise and optimise the use of

their Daikin system as a total solution for their building: one that

gives perfect climate control, reduced costs and reduced

environmental impact.

New refrigerantsThe regulation on ozone depleting substances and the fluorinated

gas directive provide some special challenges. The phasing out of

R-22 refrigerants and the concerns over the environmental impact

of other refrigerants has led to pressure being brought to bear for

the development of non-fluorinated, low GWP (global warming

potential) and natural refrigerant gases. This in turn means that

refrigerant systems will have to be re-designed and re-engineered

– our engineers are already hard at work developing an alternative

product line and trying innovative modifications to our current lines.

As always, we are the innovation leaders!

GC_pre2_lowres.pdf 7 30/11/2011 12:30:45

Page 10: DAIKIN General Catalogue 2012

����

CAPACITY

10

20 3

0 40 50 60 70 80 90 100

With European legislation* pressing energy users to drastically cut energy consumption, improve energy effi ciency of

buildings and homes, and meet the Commission’s 20/20/20 targets, industry is looking at more appropriate ways to evaluate

effi ciency. Thus, the Eco-Design Directive aims at reducing the environmental impact of products in the EU. To that end an

implementing measure for air conditioners is under development and it will introduce a new method for performance

specifi cations – seasonal effi ciency – in replacement of the current method of nominal effi ciency, which has its limitations.

* EPB (Energy Performance of Buildings) Directive 2002/91/EC, ERP - Eco-Design Directive

NOMINAL EFFICIENCY OUTDATED

Measuring energy performance is not new to Europe. Such measurements are

used to provide consumers with information on air conditioner performance

so they can make intelligent choices when purchasing. Present method in

place is that of nominal effi ciency, a method, however, with limitations that

result in a signifi cant gap between rated and actual performance.

SEASONAL EFFICIENCY IN LINE WITH REAL-LIFE PERFORMANCE

To correct this situation, a more complex calculation method – seasonal effi ciency – is being developed simultaneously in

Eco-Design and prEN 14825 (inquiry version 2010). The major diff erences between seasonal and nominal calculation are:

Temperature distribution curve - coolingFrequency

Outdoor temperature (°CDB)

Current point for EER

Nominal effi ciency gives an indication on how effi cient an

air conditioner operates at a nominal condition.

Seasonal effi ciency gives an indication on how effi cient an air

conditioner operates over an entire cooling or heating season.

1 Temperature

condition:

35°C for cooling

7°C for heating

Does not often occur

in reality

NOMINAL SEASONAL

Several rating

temperatures

for cooling and

heating, refl ecting actual performance

over an entire season

Temperature

NOMINAL SEASONAL

Does not refl ect

partial capacity

Benefi ts of inverter

technology not visible

Integrates operation at

partial instead of full

capacity

Benefi ts of inverter technology are shown

Capacity

NOMINAL SEASONAL

Does not take

auxiliary power modes

into account

Includes consumption

auxiliary modes:

• Thermostat off

• Standby mode• OFF mode• Crankcase heater

Auxiliary modes

������� ���������2013

����� Today�� Defi nes a better representation

of effi ciency: seasonal effi ciency

�� Earliest implementation in 2013

�> Actively contributes to the development of the Eco-Design methodology for air conditioners by sharing experience and

technical knowledge.

�> First to integrate Eco-Design principle in the light commercial segment by launching

Sky Air ranges optimized for seasonal

effi ciency.

�> Seasonal smart series already comply with

the EU's 2014 Eco-Design requirements.

�> Daikin off ers now a complete light

commercial range of products.

Daikin leads the way to seasonal effi ciency

GC_pre2_lowres.pdf 8 30/11/2011 12:30:45

Page 11: DAIKIN General Catalogue 2012

2004 2005 2006 … 2009 2010 2011 … 2014 2015

What is R-22 and why is it to be phased-out in Europe?

When will R-22 be banned in Europe?

1 Recycled: re-use of R-22 following a basic cleaning process. Recycled R-22 must be re-used by the same company that carried out the recovery (can be done by installer)

Reclaimed: reprocessed R-22 in order to meet the equivalent performance of virgin R-22 (by specialized company)

Ban of the sale of R-22 air

conditioning equipmentOnly reclaimed & recycled 1

R-22 allowed

Daikin advises the replacement

of your existing R-22 installation

Ban on the use of virgin R-22 for

service & maintenance

Ban on the use

of all R-22 for service & maintenance

R-22 is a hydrochlorofluorocarbon (HCFC) which was commonly

used in air conditioning systems. When R-22 is released into the

air, the ultraviolet rays of the sun cause it to decompose and

chlorine is released into the stratosphere. Chlorine reacts with

ozone, reducing the amount of the ozone.

Due to ozone layer depletion, harmful ultraviolet rays reach

the surface of the earth giving rise to a number of health

and environmental issues. The international community

therefore, signed the Montreal Protocol to phase out ozone

depletion materials by 2030. The European Union, however,

decided to ban R-22 already in 2015.

The R-22 phase out regulation will impact on all currently

operating R-22 systems, although reliable R-22 equipment does

not need to be replaced immediately because maintenance

can be carried out with recycled or reclaimed R-22 until

1st January 2015. However, not enough R-22 is currently

reclaimed or recycled to cover the demand. As a consequence,

supply shortages and price increases are expected. If there

is no reclaimed or recycled R-22 available, certain repairs (for

example: compressor change) will no longer be possible and

considerable air conditioning system downtime can occur.

It is therefore worthwhile to consider a replacement system before 2015, especially

for air conditioning systems with a large impact on the daily running of the business.

The Daikin solutionto upgrade R-22 and R-407C systems

Due to significant developments in heat pump

technology, today’s air conditioning systems,

running on R-410A refrigerant, offer better

performances than R-22 and R-407C systems did in

the past. Furthermore, R-22 will be soon unavailable

in Europe. Already today, only reclaimed or recycled

R-22 can be used for servicing. To upgrade R-22

and R-407C systems as cost effectively as possible,

Daikin units can be installed using existing pipe

work. Replacement technology is available for

residential and commercial applications in the

following ranges: Split Sky Air VRV

What is the impact on an R-22 installation?

The Daikin solutionThanks to Daikin technology, Split, Sky Air and VRV pipe work can be re-used allowing a cost eff ective upgrade of R-22 and R-407C systems.

Daikin solutions to R-22 phase out

GC_pre2_lowres.pdf 9 30/11/2011 12:30:45

Page 12: DAIKIN General Catalogue 2012

10

4 52

3

1Streamer Discharge unit

6

Because Daikin caresPure air

Streamer technology air purifier

› stylish design

› improved performance

› unprecedented comfort

› super quiet operation

› easy to maintain

› portable

› no installation

The streamer technology air purifier, a blend of new technology,

improved performance, and ultra quiet operation, it is designed

to care for you by unobtrusively providing purified air to produce

a healthy home environment. Purified air improves the

perception of comfort and, by removing and destroying

contaminants and odours, the streamer technology air purifier

also plays an essential role for those who suffer from asthma or

allergies. These efforts place the streamer technology air purifier

among the best residential air purifiers on the market today.

Three times purifi cation,

a good deed for your health

Pollen, dust and pet hair are just some of the potential causes

of allergies, asthma and respiratory problems. A Daikin air

purifier cleans the air and relieves you of these troubles thanks

to a three-part operation:

› allergen removal

› virus and bacteria removal

› odour removal

Six-layer powerful decomposition

and removal confi guration

Dust and pollen

are absorbed

by the electrically

charged filter

Electrostatic dust

collection filter(front of pleated dust collection filter)

Odours and viruses are kept

under control by

photocatylist

Titanium apatite filter

(back of pleated dust

collection filter)

Dust is captured.

Bacteria and allergens are removed

Prefilter

Dust and pollen are electrically

charged and then

sent to the filter

Plasma ionizer

High-speed electrons are discharged that enable decomposition and removal

Clean airDirty air

Formaldehyde and odours are

decomposed

Deodorising catalyst filter

MC70LVM

GC_pre2_lowres.pdf 10 30/11/2011 12:30:45

Page 13: DAIKIN General Catalogue 2012

MC70L

46

576x403x241

8.5

420/285/210/130/55

16.0/24.0/32.0/39.0/48.0

0.065/0.026/0.016/0.010/0.007

1~/220-240/220-230

1111

MC70L

Daikin has already received great praise for its air purifi ers: a British Allergy Foundation

seal of approval and the TÜV Nord test mark confirm the effi ciency of our units.

Main specifi cations

What is the Daikin streamertechnology ?“Streamer Discharge” is a type of plasma discharge in which high speed electrons capable of oxidative decomposition are generated. It has the ability to eliminate bacteria and mould as well as hazardous chemical substances and allergens, etc. Compared to standard plasma discharge (glow discharge), the discharge range of Daikin’s Streamer Discharge is wider, which makes it easier for electrons to collide with oxygen and nitrogen in the air. This enables high speed electrons to be generated three dimensionally over a wide area, which results in an oxidative decomposition speed that is over 1,000 times greater with the same electrical power. Daikin’s Streamer Discharge technology has proven successful in stably generating high speed electrons, a feat that has been considered difficult up to now.

Indoor unit

Applicable room area m²

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan Type Multi Blade Fan (Sirocco fan with shroud assembly)

Air fl ow rate Air purifying Turbo/H/M/LSilent m³/h

Sound pressure level Turbo/H/M/L/Silent

Air fi lter Polypropylene net

Air purifying operation Power input Turbo/H/M/L/Silent kW

Deodorizing method Flash streamer / Titanium apatite photocatalytic fi lter / Deodorising catalyst

Bacteria fi ltering method Flash streamer / Titanium apatite photocatalytic fi lter

Dust collecting method Plasma ionizer / Electrostatic dust collection fi lter

Power supply Phase/Voltage V

GC_pre2_lowres.pdf 11 30/11/2011 12:30:45

Page 14: DAIKIN General Catalogue 2012

1212

Ururu air purifier

Daikin has already received great praise for its

air purifiers: the Daikin TüV award confirms the

efficiency of this unit.

MCK75JVM-KIndoor units MCK75JVM-K

Application Floor standing type

Applicable room area m² 46

Casing Colour Black (N1) (Panel colour: silver)

Dimensions Unit HeightxWidthxDepth mm 590/395/268

Weight Unit kg 11.0

Fan Type Multi Blade Fan (Sirocco fan with shroud assembly)

Air fl ow rate Air purifying operation Turbo/H/M/L/Silent m³/h 450/330/240/150/60

Humidifying operation Turbo/H/M/L/Silent m³/h 450/330/240/150/120

Sound pressure level

Air purifying operation Turbo/H/M/L/Silent dBA 50/43/36/26/17

Humidifying operation Turbo/H/M/L/Silent dBA 50/43/36/26/23

Humidifying operation

Power input Turbo/H/M/L/Silent kW 0.084/0.037/0.020/0.013/0.012

Humidifi cation Turbo/H/M/L/Silent ml/h 600/470/370/290/240

Water tank capacity l 4.0

Air fi lter Polypropylene net with catechin

Air purifying operation Power input Turbo/H/M/L/Silent kW 0.081/0.035/0.018/0.011/0.008

Deodorizing method Flash streamer Titanium apatite photocatalytic fi lter Deodorising catalyst

Dust collecting method Plasma ionizerElectrostatic dust collection fi lter

Sign Dust: 3 stages, Odour: 3 stages, Air fl ow rate: auto/LL/L/M/H, Turbo mode HH, anti-pollen mode Off timer: 1/4/8h

Cleaning: ionization/streamer

Power supply Name / Phase / Frequency / Voltage Hz / V VM / 1~ / 50/60 / 220-240/220-230

Type Humidifying air purifi er

There are many substances in the air you breathe such as

allergen, bacteria, virus and tobacco smoke, which causes

your health to suffer. Above all things, dryness is especially a

big issue during wintertime.

Daikin Ururu Air Purifier moisturizes the air inside your

home and relieves the effects of dry air. Just fill the 4l tank

occasionally and it will humidify your room with a maximum

volume of 600ml/h.

This useful and innovative function stems from the

incorporation of a slim line water tank and combined water

wheel and vaporisation filter assembly.

› Humidifi cation thanks to the slim water tank

› Air purifi cation

Humidifi cation and purifi cation

in one

MCK75J

GC_pre2_lowres.pdf 12 30/11/2011 12:30:46

Page 15: DAIKIN General Catalogue 2012

1313

MCK75JVM-K

Daikin Ururu Air Purifier also removes efficiently allergens (e.g. pollen, house dust mites, dust, etc.), bacteria and viruses. Additionally,

it has a high deodorizing efficiency; it eliminates efficiently tobacco smoke whilst decomposing other smells. It quickly collects

particles and breaks them down rapidly. Its quiet operation makes it ideal for quiet nights. The unit includes seven pleated filters

(one for immediate use and 6 spares).

Dirty air Purifi ed Air

Flash Streamer High-speed electrons are generated by the Flash Streamer. These electrons powerfully

break down odours and formaldehyde.

Electrostatic dust collection fi lterPositively charged dust and pollen are adsorbed

by the negatively charged filter.

Deodorising catalystOdours are adsorbed and broken

down before the air is returned into the room.

Titanium Apatite Photocatalytic Filter

Odour, bacteria and viruses are adsorbed and decomposed.

Flash Streamer unit

Pre-filter (with catechin)

Removes large dust particles

and pet hairs.

Plasma ionizer

Dust and pollen are positively charged and

sent to the electrostatic filter.

How does the humidifi cation

function work?

Water in the tank flows into the receiver tray housing the water

wheel, which lifts the water as it rotates and releases it onto

the filter. Air blown onto the filter, absorbs its moisture and

discharges it into the room as humidification.

Vaporization fi lter

air

hu

mid

air

GC_pre2_lowres.pdf 13 30/11/2011 12:30:46

Page 16: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 14 30/11/2011 12:30:46

Page 17: DAIKIN General Catalogue 2012

15

HEATING

People are becoming more and more aware of the cost of heating. Traditional heating systems

and boilers use fossil fuels, making them an expensive and not sustainable option for the

environment. Nobody wants to waste their money. Since approximately two thirds of the

heat generated by the Daikin heat pump systems, is free of charge, the perfect solution is just

around the corner. Moreover, since heat pumps consume less energy than traditional heating

systems, they also generate less CO2 emissions.

Air to water and air to air heat pumps use energy from renewable sources: the ambient air.

These energy sources are renewable and inexhaustible. Of course, heat pumps also need

energy to function (mostly electricity), but increasingly this electricity can also be generated

from renewable energy sources (solar energy, wind energy, hydropower, biomass)

It is no surprise that people throughout Europe are becoming aware of new heating

technology. In less than a decade practically all properly insulated buildings from Italy to

Norway will be heated with heat pumps. Millions of heat pumps have already been installed

in residential and commercial applications. So… why wait?

95% of our air conditioning equipment can heat and/or cool and thus are heat pumps.

The products in this chapter are optimised heating solutions as their primary scope and

purpose is heating.

AIR TO WATER HEAT PUMPS 16

Daikin Altherma low temperature 22

EKHB(H-X)-BB / ERHQ-B(B)V3/BW1 22

EKHB(H-X)-BB / ERLQ-BV3/CV3/CW1 23

EKHV(H-X)-BB / ERHQ-B(B)V3/BW1 24

EKHV(H-X)-BB / ERLQ-BV3/CV3/CW1 25

EKCB(H/X)-BB / EBHQ-BV3 26

ED(L/H)Q-BB6V3/BB6W1 27

EB(L/H)Q-BB6V3/BB6W1 28

Options 29

Daikin Altherma high temperature 34

EKHBRD-AC / ER(R/S)Q-A 36

Options 37

Daikin Altherma Flex Type 40

EKHVM(R/Y)D-A 42

EKHBRD-AC 43

EMRQ-A 44

Options 45

Daikin heat pump convector 46

FWXV-A 46

AIR TO AIR / WATER TO AIR HEAT PUMPS 48

Residential applications - Split 48

FVXG-K / RXG-K 49

FTXG-J / RXLG-K 50

FVXG-K / RXLG-K 51

FTXS-J / RXL-J 52

FVXS-F / RXL-J 53

Commercial applications - VRV 54

RXHQ-P 54

RTSYQ-P 56

RWEYQ-PR 57

GC_pre2_lowres.pdf 15 30/11/2011 12:30:47

Page 18: DAIKIN General Catalogue 2012

DAIKIN ALTHERMA

LOW TEMPERATURE

SPLIT MONOBLOC

HEATING

APPLICATION

› New houses

› Together with existing boiler (bivalent)

INSTALLATION

OF HEAT PUMP

› 1 indoor unit

› 1 outdoor unit › 1 outdoor unit

CONNECTABLE

HEATING EMITTERS

› Under floor heating

› Low temperature radiators

› Fan coil units

› Heat pump convector

COMBINABLE WITH › Domestic hot water

› Cooling

› Solar connection for hot water production

Daikin Altherma Overview

16

GC_pre2_lowres.pdf 16 30/11/2011 12:30:48

Page 19: DAIKIN General Catalogue 2012

DAIKIN ALTHERMA

HIGH TEMPERATURE

DAIKIN ALTHERMA

FLEX TYPE

SPLIT

› Renovation:

replacement of traditional boilers

› Apartments › Collective housing › Hotels › Fitness › Spa › Schools › Hospitals › Libraries

› 1 indoor unit

› 1 outdoor unit

› Several indoor units

› 1 or more outdoor units

› High temperature radiators

› Under floor heating

› Low temperature radiators

› Fan coil units

› Heat pump convector

› Domestic hot water

› Solar connection for hot water production

› Domestic hot water

› Cooling ( Heat recovery)

17

GC_pre2_lowres.pdf 17 30/11/2011 12:30:48

Page 20: DAIKIN General Catalogue 2012

Daikin Altherma low temperature split

OUTDOOR DOMESTIC HOT WATER TANK

Down to -20°C outdoor temp. ERHQ-BBV3 ERHQ-BBV3 ERHQ-BBV3ERHQ-BV3ERHQ-BW1

ERHQ-BV3ERHQ-BW1

ERHQ-BV3ERHQ-BW1

EKHTS-AC EKHWS-B EKHWE-A

Down to -25°C outdoor temp. ERLQ-BBV3 ERLQ-BBV3 ERLQ-BBV3ERLQ-CV3ERLQ-CW1

ERLQ-CV3ERLQ-CW1

ERLQ-CV3ERLQ-CW1

INDOOR Range 006 007 008 011 014 016 200-260 150-200-300 150-200-300

Wal

l mo

un

ted

EKHBH-BB

008 heating only

hot water + solar (opt.)

016 heating only

EKHBX-BB

008 heating & cooling

016 heating & cooling

Flo

or

stan

din

g

EKHVH-BB

008 heating only

hot water + solar (opt.)

016 heating only

EKHVX-BB

008 heating & cooling

016 heating & cooling

MONOBLOC DOMESTIC HOT WATER TANK

With bottom plate heaterEDLQ-BB6V3 EDLQ-BB6W1

EDLQ-BB6V3 EDLQ-BB6W1

EDLQ-BB6V3 EDLQ-BB6W1

EBLQ-BB6V3 EBLQ-BB6W1

EBLQ-BB6V3 EBLQ-BB6W1

EBLQ-BB6V3 EBLQ-BB6W1

EKHTS-AC EKHWS-B EKHWE-A

Without bottom plate heaterEDHQ-BB6V3 EDHQ-BB6W1

EDHQ-BB6V3 EDHQ-BB6W1

EDHQ-BB6V3 EDHQ-BB6W1

EBHQ-BB6V3 EBHQ-BB6W1

EBHQ-BB6V3 EBHQ-BB6W1

EBHQ-BB6V3 EBHQ-BB6W1

006 007 008 011 014 016 200-260 150-200-300 150-200-300

heating only heating & coolinghot water + solar (opt.)

Combination tables

18

GC_pre2_lowres.pdf 18 30/11/2011 12:30:48

Page 21: DAIKIN General Catalogue 2012

Daikin Altherma Flex Type

OUTDOOR DOMESTIC HOT WATER TANK

EMRQ-A EMRQ-A EMRQ-A EMRQ-A EMRQ-A EKHTS-AC

INDOOR Range 8 10 12 14 16 200-260

Flo

or

stan

din

g

EKHVMRD-A

50

heating only

hot water

80

EKHVMYD-A

50

heating & cooling

80

EKHBRD-AC

011

heating only014

016

Daikin Altherma high temperature split

OUTDOOR DOMESTIC HOT WATER TANK

ERRQ-A ERRQ-A ERRQ-A EMRQ-A EMRQ-A EMRQ-A EMRQ-A EMRQ-AEKHTS-AC EKHWP-A

ERSQ-A ERSQ-A ERSQ-A

INDOOR Range 011 014 016 8 10 12 14 16 200-260 300-500

Flo

or

stan

din

g

EKHBRD-AC

011

heating only hot waterhot water + solar

(opt.)014

016

19

GC_pre2_lowres.pdf 19 30/11/2011 12:30:48

Page 22: DAIKIN General Catalogue 2012

20

ab

c

1

Daikin Altherma low temperature split

Heat pump convector

Although the Daikin Altherma system is compatible with all

types of heat emitters such as under floor heating, radiators and

fan coil units, the optimal solution is the heat pump convector

which is much more than a fan coil unit or any other heat

emitter. It can provide both heating and cooling if required and

obtains optimal energy efficiency by approximately 25% when

connected to a Daikin Altherma low temperature system in

combination with under floor heating.

Domestic hot water tank

A split system consists

of an outdoor unit and an indoor unit

The outdoor unit is compact and requires no drilling or

excavation work, making it easy to install in houses and

apartments. This unit extracts heat from the outside air and

raises its temperature to a level high enough to provide heating.

This heat is then transferred - via refrigerant pipes, which, of

course, can never freeze - to the indoor unit, which is available

as either a floor standing or wall-mounted unit. Here the heat

(up to 55°C) is transferred to the under floor heating, heat pump

convectors, low temperature radiators or regular fan coil units

and the domestic hot water system. If a heating and cooling

combination is desired, then the indoor unit can lower the

temperature to distribute a refreshing coolness.

Available capacities for split systems: 6, 7, 8 kW and 11, 14, 16 kW

for new housesHeating, domestic hot water & cooling

Split system

Easy control

With the wired or wireless room thermostat*, the ideal temperature

can be easily, quickly and conveniently regulated. It allows for more

precise measurement , thus allowing your customer to regulate the

comfort levels optimally and more energy efficiently.

b -Outdoor unit

c - Domestic hot water tank

a - Indoor unit

New floor standing model

As for the domestic hot water, Daikin Altherma is just as clever.

The water inside the storage tank is initially warmed up by

thermal energy from the outside air, thanks to the connection

with the indoor unit.

The standard domestic hot water tank with a stainless steel finish

is available in different sizes and capacities.

*EKRTW for wired wall mounted and EKRTR for the wireless type.

GC_pre2_lowres.pdf 20 30/11/2011 12:30:48

Page 23: DAIKIN General Catalogue 2012

21

2

Daikin Altherma low temperature monobloc

Everything combined in one outdoor unit

In addition to Daikin Altherma split systems, Daikin has introduced

a monobloc version in which all hydraulic parts are located within

the outdoor unit. In this system, the water pipes, rather than the

refrigerant pipes, run indoors from the outdoor unit, making

installation much quicker and easier for the domestic installer.

Available capacities for monobloc: 6, 8 kW and 11, 14, 16 kW

Monobloc system

Daikin Altherma offers

two low temperature systems

including a domestic hot water system all of which connect

to the same range of accessories.

Accessories for low temperature applications

New extra small casing

Outdoor unit only

Solar connection

To save even more energy on your domestic hot water

production, the Daikin Altherma system can be connected to a

solar system.The high-efficiency collectors transfer all the short-

wave solar radiation into heat as a result of their highly selective

coating. The collectors can be mounted on the roof tiles.

Under floor heating

As Rotex is part of the Daikin group, all heating supplies can be offered. For

more information, contact your local supplier.

GC_pre2_lowres.pdf 21 30/11/2011 12:30:49

Page 24: DAIKIN General Catalogue 2012

22

Outdoor unit

Heating capacity Min. kW

Nom. kW

Max. kW

Cooling capacity Min. kW

Nom. kW

Max. kW

Power input Heating Nom. kW

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Cooling Min.~Max. °CDB

Domestic hot water Min.~Max. °CDB

Refrigerant Type R-410A R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230 W1/3N~/50/400

Current Recommended fuses A

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

Indoor unit

Casing Colour RAL9010

Material Epoxy polyester painted galvanised steel

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °C

Water side Min.~Max. °C

Sound power level Medium speed 0 ESP dBA

Sound pressure level Medium speed 0 ESP dBA

› Wall mounted indoor unit › Outdoor unit extracts heat from the outdoor air, even at -25°C (ERLQ-C) › Energy efficient heating and cooling system based

on air to water heat pump technology › Flexible configuration with respect to heat emitters › Low energy bills and low CO

2 emissions

› Eco-label certified › Inverter controlled swing or scroll compressor

Daikin Altherma low temperature split

Heating onlyHeating

& Cooling Heating & Cooling

Heating & CoolingHeating & CoolingHeating & Cooling

Heating only

22

ERHQ006BBV3 ERHQ007BBV3 ERHQ008BBV3 ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1

4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) - - - - - -

5.75 (1) / 5.03 (2) 6.84 (1) / 6.10 (2) 8.43 (1) / 7.64 (2) 11.2 (1) / 10.3 (2) 14.0 (1) / 13.1 (2) 16.0 (1) / 15.2 (2) 11.32 (1) / 10.98 (2) 14.50 (1) / 13.57 (2) 16.05 (1) / 15.11 (2)

7.45 (1) / 6.68 (2) 8.79 (1) / 7.98 (2) 9.58 (1) / 8.76 (2) - - - - - -

4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) - - - - - -

7.20 (1) / 5.12 (2) 8.16 (1) / 5.86 (2) 8.37 (1) / 6.08 (2) 13.9 (1) / 10.0 (2) 17.3 (1) / 12.5 (2) 17.8 (1) / 13.1 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2)

7.20 (1) / 5.12 (2) 8.50 (1) / 6.13 (2) 8.91 (1) / 7.10 (2) - - - - - -

1.26 (1) / 1.58 (2) 1.58 (1) / 1.95 (2) 2.08 (1) / 2.54 (2) 2.46 (1) / 3.06 (2) 3.17 (1) / 3.88 (2) 3.83 (1) / 4.66 (2) 2.54 (1) / 3.15 (2) 3.33 (1) / 4.12 (2) 3.73 (1) / 4.60 (2)

4.56 (1) / 3.18 (2) 4.34 (1) / 3.13 (2) 4.05 (1) / 3.00 (2) 4.55 (1) / 3.37 (2) 4.42 (1) / 3.38 (2) 4.18 (1) / 3.26 (2) 4.46 (1) / 3.48 (2) 4.35 (1) / 3.29 (2) 4.30 (1) / 3.29 (2)

735x825x300 1,170x900x320 1,345x900x320

56 103 108

-15~25 -20~35 -20~35

10~43 - 10~46

-15~35 -20~43 -20~43

1.7 3.7 2.95

61 62 - 64 66

63 - 64 66 69

48 49 49 51 53 51 52

48 50 - 50 52 54

20 32 20

EKHBH008BB EKHBX008BB EKHBH016BB EKHBX016BB

922x502x361

46 48

-20 (1) / -25 (2)~35

15~50

- 10~43 - 10~43

- 5~22 - 5~22

42

28

22

EKHBH(X)-BB

Down to -20°C outdoor t°

ER(H/L)Q006-008BBV3 ER(H/L)Q011-016BV3/CV3

EKHB(H/X)-BB / ERHQ-(BBV3/BV3/BW1)

GC_pre2_lowres.pdf 22 30/11/2011 12:30:49

Page 25: DAIKIN General Catalogue 2012

23

Outdoor unit

Heating capacity Min. kW

Nom. kW

Max. kW

Cooling capacity Min. kW

Nom. kW

Max. kW

Power input Heating Nom. kW

Max. kW

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Cooling Min.~Max. °CDB

Domestic hot water Min.~Max. °CDB

Refrigerant Type R-410A R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230 W1/3N~/50/400

Current Recommended fuses A

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

Down to -25°C outdoor t°Indoor unit

Casing Colour RAL9010

Material Epoxy polyester painted galvanised steel

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °C

Water side Min.~Max. °C

Sound power level Medium speed 0 ESP dBA

Sound pressure level Medium speed 0 ESP dBA

Heating onlyHeating

& Cooling Heating & Cooling

Heating & CoolingHeating & CoolingHeating & Cooling

Heating only

23

ERLQ006BBV3 ERLQ007BBV3 ERLQ008BBV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 ERLQ011CW1 ERLQ014CW1 ERLQ016CW1

4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) - - - - - -

5.75 (1) / 5.03 (2) 6.84 (1) / 6.10 (2) 8.43 (1) / 7.64 (2) 11.20 (1) / 10.98 (2) 14.00 (1) / 13.57 (2) 16.00 (1) / 15.20 (2) 11.20 (1) / 10.98 (2) 14.00 (1) / 13.57 (2) 16.00 (1) / 15.20 (2)

7.45 (1) / 6.68 (2) 8.79 (1) / 7.98 (2) 9.58 (1) / 8.76 (2) 8.81 (3) / 8.16 (4) 11.65 (3) / 10.96 (4) 12.30 (3) / 11.35 (4) 8.81 (3) / 8.16 (4) 11.65 (3) / 10.96 (4) 12.30 (3) / 11.35 (4)

4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) - - - - - -

7.20 (1) / 5.12 (2) 8.16 (1) / 5.86 (2) 8.37 (1) / 6.08 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2)

7.20 (1) / 5.12 (2) 8.50 (1) / 6.13 (2) 8.91 (1) / 7.10 (2) - - - - - -

1.26 (1) / 1.58 (2) 1.58 (1) / 1.95 (2) 2.08 (1) / 2.54 (2) 2.41 (1) / 3.15 (2) 3.14 (1) / 4.12 (2) 3.72 (1) / 4.60 (2) 2.41 (1) / 3.15 (2) 3.14 (1) / 4.12 (2) 3.72 (1) / 4.60 (2)

- - - 3.43 (3) / 4.05 (4) 4.86 (3) / 5.57 (4) 5.40 (3) / 6.25 (4) 3.43 (3) / 4.05 (4) 4.86 (3) / 5.57 (4) 5.40 (3) / 6.25 (4)

4.56 (1) / 3.18 (2) 4.34 (1) / 3.13 (2) 4.05 (1) / 3.00 (2) 4.66 (1) / 3.48 (2) 4.46 (1) / 3.29 (2) 4.30 (1) / 3.29 (2) 4.66 (1) / 3.48 (2) 4.46 (1) / 3.29 (2) 4.30 (1) / 3.29 (2)

735x825x300 1,345x900x320 1,345x900x320

57 113 114

-15~25 -25~35 -25~35

10~43 10.0~46.0 10~46

-15~35 -20~35 -20~35

1.7 3.4 3.4

61 62 64 66 64 66

63 64 66 69 64 66 69

48 49 51 52 51 52

48 50 50 52 54 50 52 54

20 40 20

EKHBH008BB EKHBX008BB EKHBH016BB EKHBX016BB

922x502x361

46 48

-20 (1) / -25 (2)~35

15~50

- 10~43 - 10~43

- 5~22 - 5~22

42

28

23

EKHB(H/X)-BB / ERLQ-(BBV3/CV3/CW1)

GC_pre2_lowres.pdf 23 30/11/2011 12:30:49

Page 26: DAIKIN General Catalogue 2012

24

Outdoor unit

Heating capacity Min. kW

Nom. kW

Max. kW

Heating capacity Min. kW

Nom. kW

Max. kW

Power input Heating Nom. kW

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Cooling Min.~Max. °CDB

Domestic hot water Min.~Max. °CDB

Refrigerant Type R-410A R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230 W1/3N~/50/400

Current Recommended fuses A

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

Down to -20°C outdoor t°Indoor unit

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water Water side Min.~Max. °C

Sound power level Medium speed 0 ESP dBA

Sound pressure level Medium speed 0 ESP dBA

› Floor standing indoor unit › Outdoor unit extracts heat from the outdoor air, even at -25°C (ERLQ-C) › Energy efficient heating and cooling system based

on air to water heat pump technology › Flexible configuration with respect to heat emitters › Low energy bills and low CO

2 emissions

› Eco-label certified › Inverter controlled swing or scroll compressor

Daikin Altherma low temperature split

Heating onlyHeating

& Cooling Heating & CoolingHeating only

Heating & CoolingHeating & CoolingHeating & Cooling

24

ERHQ006BBV3 ERHQ007BBV3 ERHQ008BBV3 ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1

4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) - - - - - -

5.75 (1) / 5.03 (2) 6.84 (1) / 6.10 (2) 8.43 (1) / 7.64 (2) 11.2 (1) / 10.3 (2) 14.0 (1) / 13.1 (2) 16.0 (1) / 15.2 (2) 11.32 (1) / 10.98 (2) 14.50 (1) / 13.57 (2) 16.05 (1) / 15.11 (2)

7.45 (1) / 6.68 (2) 8.79 (1) / 7.98 (2) 9.58 (1) / 8.76 (2) - - - - - -

4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) - - - - - -

7.20 (1) / 5.12 (2) 8.16 (1) / 5.86 (2) 8.37 (1) / 6.08 (2) 13.9 (1) / 10.0 (2) 17.3 (1) / 12.5 (2) 17.8 (1) / 13.1 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2)

7.20 (1) / 5.12 (2) 8.50 (1) / 6.13 (2) 8.91 (1) / 7.10 (2) - - - - - -

1.26 (1) / 1.58 (2) 1.58 (1) / 1.95 (2) 2.08 (1) / 2.54 (2) 2.46 (1) / 3.06 (2) 3.17 (1) / 3.88 (2) 3.83 (1) / 4.66 (2) 2.54 (1) / 3.15 (2) 3.33 (1) / 4.12 (2) 3.73 (1) / 4.60 (2)

4.56 (1) / 3.18 (2) 4.34 (1) / 3.13 (2) 4.05 (1) / 3.00 (2) 4.55 (1) / 3.37 (2) 4.42 (1) / 3.38 (2) 4.18 (1) / 3.26 (2) 4.46 (1) / 3.48 (2) 4.35 (1) / 3.29 (2) 4.30 (1) / 3.29 (2)

735x825x300 1,170x900x320 1,345x900x320

56 103 108

-15~25 -20~35 -20~35

10~43 - 10~46

-15~35 -20~43 -20~43

1.7 3.7 2.95

61 62 - 64 66

63 - 64 66 69

48 49 49 51 53 51 52

48 50 - 50 52 54

20 32 20

EKHVH008BB EKHVX008BB EKHVH016BB EKHVX016BB

705x600x695

65

-20~35

15 ~50

- 10~46 - 10~46

- 5~22 - 5~22

25~60

42

28

24

EKHV(H/X)-BB / ERHQ-(BBV3/BV3/BW1)

EKHVH(X)008-016BB ER(H/L)Q006-008BBV3 ER(H/L)Q011-016BV3/CV3

GC_pre2_lowres.pdf 24 30/11/2011 12:30:49

Page 27: DAIKIN General Catalogue 2012

25

Outdoor unit

Heating capacity Min. kW

Nom. kW

Max. kW

Cooling capacity Min. kW

Nom. kW

Max. kW

Power input Heating Nom. kW

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Cooling Min.~Max. °CDB

Domestic hot water Min.~Max. °CDB

Refrigerant Type R-410A R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230 W1/3N~/50/400

Current Recommended fuses A

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)

Down to -25°C outdoor t°Indoor unit

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water Water side Min.~Max. °C

Sound power level Medium speed 0 ESP dBA

Sound pressure level Medium speed 0 ESP dBA

Heating onlyHeating

& Cooling Heating & CoolingHeating only

Heating & CoolingHeating & CoolingHeating & Cooling

25

ERLQ006BBV3 ERLQ007BBV3 ERLQ008BBV3 ERLQ011CV3 ERLQ014CV3 ERLQ016CV3 ERLQ011CW1 ERLQ014CW1 ERLQ016CW1

4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) 4.36 (1) / 3.87 (2) 11.20 (1) / 10.98 (2) 14.00 (1) / 13.57 (2) 16.00 (1) / 15.20 (2) 11.20 (1) / 10.98 (2) 14.00 (1) / 13.57 (2) 16.00 (1) / 15.20 (2)

5.75 (1) / 5.03 (2) 6.84 (1) / 6.10 (2) 8.43 (1) / 7.64 (2) 8.81 (3) / 8.16 (4) 11.65 (3) / 10.96 (4) 12.30 (3) / 11.35 (4) 8.81 (3) / 8.16 (4) 11.65 (3) / 10.96 (4) 12.30 (3) / 11.35 (4)

7.45 (1) / 6.68 (2) 8.79 (1) / 7.98 (2) 9.58 (1) / 8.76 (2) 2.41 (1) / 3.15 (2) 3.14 (1) / 4.12 (2) 3.72 (1) / 4.60 (2) 2.41 (1) / 3.15 (2) 3.14 (1) / 4.12 (2) 3.72 (1) / 4.60 (2)

4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) 4.82 (1) / 3.67 (2) - - - - - -

7.20 (1) / 5.12 (2) 8.16 (1) / 5.86 (2) 8.37 (1) / 6.08 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2) 15.05 (1) / 11.72 (2) 16.06 (1) / 12.55 (2) 16.76 (1) / 13.12 (2)

7.20 (1) / 5.12 (2) 8.50 (1) / 6.13 (2) 8.91 (1) / 7.10 (2) - - - - - -

1.26 (1) / 1.58 (2) 1.58 (1) / 1.95 (2) 2.08 (1) / 2.54 (2) 3.43 (3) / 4.05 (4) 4.86 (3) / 5.57 (4) 5.40 (3) / 6.25 (4) 3.43 (3) / 4.05 (4) 4.86 (3) / 5.57 (4) 5.40 (3) / 6.25 (4)

4.56 (1) / 3.18 (2) 4.34 (1) / 3.13 (2) 4.05 (1) / 3.00 (2) 4.66 (1) / 3.48 (2) / 2.57 (3) / 2.01 (4) 4.46 (1) / 3.29 (2) / 2.40 (3) / 1.97 (4) 4.30 (1) / 3.29 (2) / 2.28 (3) / 1.82 (4) 4.66 (1) / 3.48 (2) / 2.57 (3) / 2.01 (4) 4.46 (1) / 3.29 (2) / 2.40 (3) / 1.97 (4) 4.30 (1) / 3.29 (2) / 2.28 (3) / 1.82 (4)

735x825x300 1,345x900x320 1,345x900x320

57 113 114

-15~25 -25~35 -25~35

10~43 10.0~46.0 10~46

-15~35 -20~35 -20~35

1.7 3.4 3.4

61 62 64 66 64 66

63 64 66 69 64 66 69

48 49 51 52 51 52

48 50 50 52 54 50 52 54

20 40 20

EKHVH008BB EKHVX008BB EKHVH016BB EKHVX016BB

705x600x695

65

-20~35

15 ~50

- 10~46 - 10~46

- 5~22 - 5~22

25~60

42

28

25

EKHV(H/X)-BB / ERLQ-(BBV3/CV3/CW1)

GC_pre2_lowres.pdf 25 30/11/2011 12:30:49

Page 28: DAIKIN General Catalogue 2012

26

Outdoor unit

Heating capacity Nom. kW

Cooling capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

COP

EER

Dimensions Unit Height mm

Width mm

Depth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °CWB

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Compressor component

Main power supply

Name V3

Phase

Frequency Hz

Voltage V

(1) EN14511: cooling Ta 35°C - LWE 18°C (Dt = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (Dt = 5°C) (2) EN14511: cooling Ta 35°C - LWE 7°C (Dt = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (Dt = 5°C )

› Single phase reversible monobloc (EBHQ-BV3) › Single and three phase reversible only monobloc (ED(L/H)Q-BB) › Energy efficient heating and cooling system based

on air to water heat pump technology › H

2O piping between outdoor unit and indoor heat emitters

› Low energy bills and low CO2 emissions

› Eco-label certified › Built-in electric back-up heater as additional heating

during extremely cold outdoor temperature › Inverter controlled swing compressor

Daikin Altherma low temperature monobloc

6kW to 8kWControl box

Dimensions Unit Height mm

Width mm

Depth mm

Depth with remocon mounted on front plate

mm

Weight Unit kg

Operation range Indoor installation

Ambient Min. °CDB

Max. °CDB

Heating & Cooling

Heating & Cooling

Heating only

Heating & Cooling

26

EBHQ006BV3 EBHQ008BV3

6.00 (1) / 5.58 (2) 8.85 (1) / 8.15 (2)

7.00 (1) / 5.12 (2) 8.37 (1) / 6.08 (2)

2.20 (1) / 2.16 (2) 2.97 (1) / 2.75 (2)

1.41 (1) / 1.79 (2) 2.21 (1) / 2.72 (2)

4.26 (1) / 3.11 (2) 4.00 (1) / 3.00 (2)

3.18 (1) / 2.37 (2) 2.82 (1) / 2.21 (2)

805

1,190

360

95

-15~25

15~50

10~43

5~22

-15~35

25~80

1.7

61 62

63

48 49

48 50

1~

50

230

EKCBH008BBV3 EKCBX008BBV3

390

412

100

120

6

4

35

26

EBHQ-BV3

EBHQ-BV3EKCB(H/X)BB

EKCBH(X)-BB EB(L/H)Q-BB

GC_pre2_lowres.pdf 26 30/11/2011 12:30:50

Page 29: DAIKIN General Catalogue 2012

27

Heating & CoolingWith bottom plate heater

Without bottom plate heater

Heating capacity Nom. kW

Cooling capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

COP

EER

Dimensions Unit Height mm

Width mm

Depth mm

Weight Unit kg

Hydraulic

component

Back-up heater

current

Type

Power supply

Phase/Frequency/Voltage

Hz/V

Operation range Heating Ambient Min.~Max. °CWB

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Domestic hot

water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Cooling Nom. dBA

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Compressor component

Main power supply

Name V3 W1

Phase

Frequency Hz

Voltage V

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

(3) Back up heater only between 15°C and 25°C, no heat pump operation during commissioning

› Single and three phase heating only monobloc (EB(L/H)Q-BB) › Energy efficient heating and cooling system based

on air to water heat pump technology › H

2O piping between outdoor unit and indoor heat emitters

› Low energy bills and low CO2 emissions

› Eco-label certified › Built-in electric back-up heater as additional heating

during extremely cold outdoor temperature › Inverter controlled scroll compressor

Daikin Altherma low temperature monobloc

27

EBLQ011BB6V3 EBLQ014BB6V3 EBLQ016BB6V3 EBLQ011BB6W1 EBLQ014BB6W1 EBLQ016BB6W1

EBHQ011BB6V3 EBHQ014BB6V3 EBHQ016BB6V3 EBHQ011BB6W1 EBHQ014BB6W1 EBHQ016BB6W1

11.20 (1) / 10.87 (2) 14.00 (1) / 13.10 (2) 16.00 (1) / 15.06 (2) 11.20 (1) / 10.87 (2) 14.00 (1) / 13.10 (2) 16.00 (1) / 15.06 (2)

12.85 (1) / 10.00 (2) 15.99 (1) / 12.50 (2) 16.73 (1) / 13.10 (2) 12.85 (1) / 10.00 (2) 15.99 (1) / 12.50 (2) 16.73 (1) / 13.10 (2)

3.78 (1) / 3.60 (2) 5.65 (1) / 5.30 (2) 6.28 (1) / 5.85 (2) 3.78 (1) / 3.60 (2) 5.32 (1) / 4.98 (2) 6.06 (1) / 5.65 (2)

2.47 (1) / 3.22 (2) 3.20 (1) / 3.91 (2) 3.79 (1) / 4.62 (2) 2.51 (1) / 3.12 (2) 3.22 (1) / 3.98 (2) 3.72 (1) / 4.58 (2)

4.54 (1) / 3.37 (2) 4.37 (1) / 3.35 (2) 4.22 (1) / 3.26 (2) 4.46 (1) / 3.48 (2) 4.35 (1) / 3.29 (2) 4.30 (1) / 3.29 (2)

3.39 (1) / 2.78 (2) 2.83 (1) / 2.36 (2) 2.66 (1) / 2.24 (2) 3.39 (1) / 2.78 (2) 3.01 (1) / 2.51 (2) 2.76 (1) / 2.32 (2)

1,418 1,418

1,435 1,435

382 382

180 180

6V3 6W1

1~/50/230 3~/50/400

-20~35 (EBLQ) / -15~35 (EBHQ) -25~35 (EBLQ) / -15~35 (EBHQ)

15(3)~55(3) 15(3)~55(3)

10~46 10~46

5~22 5~22

-20~43 (EBLQ) / -15~43 (EBHQ) -25~43 (EBLQ) / -15~43 (EBHQ)

25~80 25~80

2.95 2.95

64 65 66 64 65 66

65 66 69 65 66 69

51 52 49 51 53

50 52 54 50 52 54

1~ 3N~

50 50

230 400

27

EB(L/H)Q-BB6(V3/W1)

GC_pre2_lowres.pdf 27 30/11/2011 12:30:50

Page 30: DAIKIN General Catalogue 2012

28

Heating only - 11kW to 16kWWith bottom plate heater

Without bottom plate heater

Heating capacity Nom. kW

Power input Heating Nom. kW

COP

Dimensions Unit Height mm

Width mm

Depth mm

Weight Unit kg

Hydraulic component

Back-up heater current

Type

Power supply

Phase/Frequency/Voltage

Hz/V

Operation range Heating Ambient Min.~Max. °CWB

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Sound pressure level Heating Nom. dBA

Compressor component

Main power supply

Name V3 W1

Phase

Frequency Hz

Voltage V

(1) Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

(3) Back up heater only between 15°C and 25°C, no heat pump operation during commissioning

› Single and three phase reversible monobloc (ED(L/H)Q-BB) › Energy efficient heating and cooling system based

on air to water heat pump technology › H

2O piping between outdoor unit and indoor heat emitters

› Low energy bills and low CO2 emissions

› Eco-label certified › Built-in electric back-up heater as additional heating

during extremely cold outdoor temperature › Inverter controlled scroll compressor

28

EDLQ011BB6V3 EDLQ014BB6V3 EDLQ016BB6V3 EDLQ011BB6W1 EDLQ014BB6W1 EDLQ016BB6W1

EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1

11.20 (1) / 10.87 (2) 14.00 (1) / 13.10 (2) 16.00 (1) / 15.06 (2) 11.20 (1) / 10.87 (2) 14.00 (1) / 13.10 (2) 16.00 (1) / 15.06 (2)

2.47 (1) / 3.22 (2) 3.20 (1) / 3.91 (2) 3.79 (1) / 4.62 (2) 2.51 (1) / 3.12 (2) 3.22 (1) / 3.98 (2) 3.72 (1) / 4.58 (2)

4.54 (1) / 3.37 (2) 4.37 (1) / 3.35 (2) 4.22 (1) / 3.26 (2) 4.46 (1) / 3.48 (2) 4.35 (1) / 3.29 (2) 4.30 (1) / 3.29 (2)

1,418 1,418

1,435 1,435

382 382

180 180

6V3 6W1

1~/50/230 3~/50/400

-20~35 (EDLQ) / -15~35 (EDHQ) -25~35 (EDLQ) / -15~35 (EDHQ)

15(3)~55(3) 15(3)~55(3)

-20~43 (EDLQ) / -15~43 (EDHQ) -25~43 (EDLQ) / -15~43 (EDHQ)

25~80 25~80

2.95 2.95

64 65 66 64 65 66

51 52 49 51 53

1~ 3N~

50 50

230 400

28

ED(L/H)Q-BB6(V3/W1)

GC_pre2_lowres.pdf 28 30/11/2011 12:30:50

Page 31: DAIKIN General Catalogue 2012

29

Domestic hot water tank

Casing Colour Metallic grey

Material Galvanised steel (precoated sheet metal)

Dimensions Unit HeightxIntegrated on indoor unitxWidthxDepth

mm

Weight Unit Empty kg

Tank Water volume l

Material Stainless steel (EN 1.4521)

Maximum water temperature °C

Heat exchanger Quantity

Tube material Duplex steel (EN 1.4162)

Face area m²

Internal coil volume l

› Stainless steel domestic hot water tank › The indoor unit and domestic hot water tank can be stacked to save space,

or installed next to each other, if only limited height is available › Available in 200 and 260 liters › Heat loss is reduced to a minimum thanks to the high quality insulation › At necessary intervals, the indoor unit can heat up the water

to 60°C to prevent the risk of bacteria growth › Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes

Domestic hot water tank

Domestic hot water tanks - Survey

Whether your customer wants domestic hot water only or the

advantage of solar energy, Daikin offers you the domestic hot

water tank that meets his or her requirements.

Domestic hot water tank

EKHTS-AC EKHWS-B EKHWE-A

INDOOR 200-260 150-200-300 150-200-300

Wall mounted

EKHBH-BB

hot water + solar (opt.)

EKHBX-BB

floor standing

EKHVH-BB

hot water + solar (opt.)

EKHVX-BB

MONOBLOC 200-260 150-200-300 150-200-300

With bottom plate heaterEDLQ-BB6V3 / EDLQ-BB6W1

hot water + solar (opt.)EBLQ-BB6V3 / EBLQ-BB6V3

Without bottom plate heaterEDHQ-BB6V3 / EDHQ-BB6W1

EBHQ-B6V3 / EBHQ-BB6V3

29

EKHTS200AC EKHTS260AC

2,010x600x695 2,285x600x695

70 78

200 260

75

1

1.56

7.5

29

EKHTS-AC

EKHTS200AC EKHTS260AC

GC_pre2_lowres.pdf 29 30/11/2011 12:30:50

Page 32: DAIKIN General Catalogue 2012

30

Domestic hot water tank

Casing Colour Neutral white

Material Epoxy-coated mild steel

Dimensions Unit HeightxWidthxDepth mm

Weight Unit Empty kg

Tank Water volume l

Material Stainless steel (DIN 1.4521)

Maximum water temperature °C

Heat exchanger Quantity

Tube material Duplex steel LDX 2101

Booster heater Capacity kW

Power supply Phase/Frequency/Voltage Hz/V

› Stainless steel domestic hot water tank › Available in 150,200 and 300 liters

Domestic hot water tank

Domestic hot water tank

Domestic hot water tank

Casing Colour RAL9010

Material Epoxy coated steel

Dimensions Unit HeightxDiameter mm

Weight Unit Empty kg

Tank Water volume l

Maximum water temperature °C

Booster heater Capacity kW

Power supply Phase/Frequency/Voltage Hz/V

› Enameled domestic hot water tank › Available in 150,200 and 300 liters

30

EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

900x580x580 1,150x580x580 1,650x580x580 1,150x580x580 1,650x580x580

37 45 59 45 59

150 200 300 200 300

85

1

3

1~/50/230 2~/50/400

EKHWE150A3V3 EKHWE200A3V3 EKHWE300A3V3 EKHWE200A3Z2 EKHWE300A3Z2

1,205x545 1,580x545 1,572x660 1,580x545 1,572x660

80 104 140 104 140

150 200 300 200 300

75

3.0

1~/50/230 2~/50/400

30

EKHWS-B

EKHWS-B

EKHWE-A

EKHWE200A

GC_pre2_lowres.pdf 30 30/11/2011 12:30:51

Page 33: DAIKIN General Catalogue 2012

31

Wireless room thermostat

Dimensions Thermostat Height/Width/Depth mm

Receiver Height/Width/Depth mm

Weight Thermostat g

Receiver g

Ambient temperature

Storage Min./Max. °C

Operation Min./Max. °C

Temperature setting range

Heating Min./Max. °C

Cooling Min./Max. °C

Clock Yes

Regulation function Proportional band

Power supply Thermostat Voltage V Battery powered 3x AA-LRG (alkaline)

Receiver Voltage V

Frequency Hz

Phase

Connection Thermostat Wireless

Receiver Wired

Maximum distance to receiver

Indoor m approx.30m

Outdoor m approx.100m

› Heating and cooling mode, with possibility to disable cooling mode if not required

› Comfort function mode activates the programmed temperature levels intended for a home occupied during the day; default setpoints are 21°C in heating mode and 24°C in cooling mode and can be changed by the user

› Reduced function mode activates the programmed temperature levels for periods when the house is unoccupied or at night; default setpoints are 17°C in heating, 28°C in cooling mode and can be changed by the user

› Scheduled function mode: uses a timer to schedule heatin and cooling setpoints throughout the day; up to 12 setpoints can be programmed per day; the selected setpoints will be automatically activated at the scheduled time

› Holiday function mode: intended for setting reduced and fuel-efficient setpoints when the house is unoccupied for long periods. The default setpoints are 14°C for heating and 30°C for cooling.

› Off function: switches the system off; however, the integrated frost protection remains activated (set by default at 4°C).

› Setpoint limitation sets the upper and lower setpoint limits within which the user can programme the desired comfort levels and can only be modified by the installer

› Number of setpoint changes: 12/day › Key lock function: possible to lock the keys of the room thermostat

Wireless and wired room thermostat

Wired room thermostat

Dimensions Unit HeightxWidthxDepth mm

Weight Unit g

Ambient

temperature

Storage Min./Max. °C

Operation Min./Max. °C

Temperature setting range

Heating Min./Max. °C

Cooling Min./Max. °C

Clock Yes

Regulation function Proportional band

Power supply Voltage V Battery powered 3* AA-LR6 (alkaline)

Connection Type Wired

31

EKRTR1

87/125/34

170/50/28

210

125

-20/60

0/50

4/37

4/37

230

50

1~

EKRTWA

87x125x34

215

-20/60

0/50

4/37

4/37

31

EKRTR

EKRTR / EKRTW

EKRTW

GC_pre2_lowres.pdf 31 30/11/2011 12:30:51

Page 34: DAIKIN General Catalogue 2012

32

Solar kit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Ambient temperature Min.~Max. °C

Sound pressure level Nom. dBA

Thermal performance Zero loss collector efficiency η0 %

Power supply Phase/Frequency/Voltage Hz/V

Power supply intake Indoor unit

› Transfers solar heat to the domestic hot water tank › Save energy and reduce CO

2 emissions with a solar

system for domestic hot water production

Solar connection

Wired remote control

Mounting On wall

Dimensions Unit HeightxWidthxDepth mm

Thermal performance Zero loss collector efficiency η0 %

Control Type Digital temperature difference controller with plain text display

Power consumption W

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return flow sensor PTC

Feed temperature and flow sensor Voltage signal (3.5V DC)

Power supply Voltage V

› Save energy and reduce CO2 emissions with a solar

system for domestic hot water production › Wired remote control for pump station EKSRDS1A,

connectable to pressurised solar system › Pump station and control provide the transfer of

solar heat to the domestic hot water tank

Wired remote control for pump station EKSRDS1A

32

EKSOLHW

770x305x270

8

1~35

27

-

1~/50/220-240

EKSR3PA

332x230x145

-

2

230

32

EKSOLHW

EKSOLHW

EKSR3P

GC_pre2_lowres.pdf 32 30/11/2011 12:30:51

Page 35: DAIKIN General Catalogue 2012

33

Solar collector

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Volume l

Surface Outer m²

Aperture m²

Absorber m²

Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)

Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate

Glazing Single pane safety glass, transmission +/- 92%

Allowed roof angle Min.~Max. °

Operating pressure Max. bar

Stand still temperature Max. °C

Thermal performance

Zero loss collector efficiency η0 %

Heat loss coefficient a1 W/m².K

Temperature dependence of the heat loss coefficient a2 W/m².K²

Thermal capacity kJ/K

Incident angle modifier AM at 50°

Installed position Vertical Horizontal

› Horizontal and vertical solar collector for domestic hot water production › Solar panels can produce up to 70% of the energy needed

for hot water production – a major cost saving › High efficiency collectors transfer all the short-wave solar

radiation into heat as a result of their highly selective coating › Easy to install on roof tiles

Solar collector

33

EKSH26P EKSV26P

1,300x2,000x85 2,000x1,300x85

43

2.1 1.7

2.601

2.364

2.354

15~80

6

200

78.7

4.270

0.0070

6.5

0.94

33

EKSH-P

EKS(H/V)-P

EKSV-P

GC_pre2_lowres.pdf 33 30/11/2011 12:30:51

Page 36: DAIKIN General Catalogue 2012

34

b a

c

1

Daikin Altherma high temperature split

for renovationsHeating & domestic hot water

A split system consists

of an outdoor unit and an indoor unit

The outdoor unit extracts heat from the ambient outdoor air.

This heat is transferred to the indoor unit via refrigerant piping.

The indoor unit receives the heat from the outdoor unit and

further increases the temperature, allowing water temperatures

up to 80°C for heating through radiators and for domestic hot

water use. Daikin’s unique cascade compressor approach to the

heat pumps (one in the outdoor unit/one in the indoor unit) means

optimum comfort at even the coldest outdoor temperatures,

without the need for an electric back-up heater.

Accessories

for high temperature applications

Split system

Easy control

With Daikin Altherma’s user interface, the ideal temperature can

be easily, quickly and conveniently regulated. It allows for more

precise measurement and can regulate your comfort even more

optimally and energy efficiently.

GC_pre2_lowres.pdf 34 30/11/2011 12:30:51

Page 37: DAIKIN General Catalogue 2012

35

c -

a -b -

2

Domestic hot water tank

Indoor unit

Outdoor unit

for low energy consumption

Daikin Altherma’s high water temperature is ideal for heating

domestic hot water without the need for an additional electric

heater. Rapid heating of domestic hot water also means smaller

heaters are needed. For a family of approximately 4 people, the

standard tank is the best solution. Should you require more hot water,

a larger tank is also available.

Domestic hot water tank

Solar connection

The Daikin Altherma high temperature heating system can

optionally use solar energy for hot water production.

If the solar energy is not required immediately, the purpose-built

hot water tank (EKHWP) can store large quantities of heated water

for up to a day for later use as domestic hot water or for heating.

Heat emitters

The Daikin Atherma high temperature system is designed to work

only with high-temperature radiators, which come in various

sizes and formats to suit the interior design as well as the heating

requirement. Our radiators can be individually controlled or they

can be regulated by the central heating control programme.

GC_pre2_lowres.pdf 35 30/11/2011 12:30:51

Page 38: DAIKIN General Catalogue 2012

36

Heating onlyIndoor unit

Casing Colour Metallic grey Metallic grey

Material Precoated sheet metal Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-134a R-134a

Charge kg

Sound pressure level

Nom. dBA

Night quiet mode Level 1 dBA

Power supply Name V1 Y1

Phase

Frequency Hz

Voltage V

Current Recommended fuses A

Outdoor unit with bottom plate heater

Outdoor unit without bottom plate heater

Heating capacity Nom. kW

Power input Heating Nom. kW

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Domestic hot water Min.~Max. °CDB

Refrigerant Type R-410A R-410A

Charge kg

Sound power level Heating Nom. dBA

Sound pressure level Heating Nom. dBA

Power supply Name/Phase/Frequency/Voltage Hz/V V1/1~/50/220-440 Y1/3~/50/380-415

Current Recommended fuses A

› High temperature application: up to 80°C without electric heater › Floor standing indoor unit up to 16kW › Energy efficient heating only system based on

air to water heat pump technology › Easy replacement of existing boiler without changing heating pipes › Combinable with high temperature radiators › Low energy bills and low CO

2 emissions

› Outdoor unit extracts heat from the outdoor air, even at -20°C › Inverter controlled scroll compressor

Daikin Altherma high temperature split

1. EW 55°C; LW 65°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB | 2. EW 70°C; LW 80°C; Dt 10°C; ambient conditions: 7°CDB/6°CWB | 3. EW 30°C; LW 35°C; Dt 5°C; ambient conditions: 7°CDB/6°CWB | 5. Sound levels are measured at: EW 55°C; LW 65°C; Dt 10°C; ambient conditions 7°CDB/6°CWB | 6. Sound levels are measured at: EW 70°C; LW 80°C; Dt 10°C; ambient conditions 7°CDB/6°CWB

36

EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

705x600x695 705x600x695

144.25 147.25

-20~20 -20~20

25~80 25~80

-20~35 -20~35

25~80 25~80

3.2 3.2

43 (5) / 46 (6) 45 (5) / 46 (6) 46 (5) / 46 (6) 43 (5) / 43 (6) 45 (5) / 45 (6) 46 (5) / 46 (6)

40 43 45 40 43 45

1~ 3~

50 50

220-240 380-415

25 16

ERRQ011AV1 ERRQ014AV1 ERRQ016AV1 ERRQ011AY1 ERRQ014AY1 ERRQ016AY1

ERSQ011AV1 ERSQ014AV1 ERSQ016AV1 ERSQ011AY1 ERSQ014AY1 ERSQ016AY1

11 (1) / 11 (2) / 11 (3) 14 (1) / 14 (2) / 14 (3) 16 (1) / 16 (2) / 16 (3) 11 (1) / 11 (2) / 11 (3) 14 (1) / 14 (2) / 14 (3) 16 (1) / 16 (2) / 16 (3)

3.57 (1) / 4.40 (2) / 2.61 (3) 4.66 (1) / 5.65 (2) / 3.55 (3) 5.57 (1) / 6.65 (2) / 4.31 (3) 3.57 (1) / 4.40 (2) / 2.61 (3) 4.66 (1) / 5.65 (2) / 3.55 (3) 5.57 (1) / 6.65 (2) / 4.31 (3)

3.08 (1) / 2.50 (2) / 4.22 (3) 3.00 (1) / 2.48 (2) / 3.94 (3) 2.88 (1) / 2.41 (2) / 3.72 (3) 3.08 (1) / 2.50 (2) / 4.22 (3) 3.00 (1) / 2.48 (2) / 3.94 (3) 2.88 (1) / 2.41 (2) / 3.72 (3)

1,345x900x320 1,345x900x320

120 120

-20~20 -20~20

-20~35 -20~35

4.5 4.5

68 69 71 68 69 71

52 53 55 52 53 55

25 16

36

EKHBRD-ACV1 ER(R-S)Q-A

EKHBRD-AC / ER(R/S)Q-A

GC_pre2_lowres.pdf 36 30/11/2011 12:30:52

Page 39: DAIKIN General Catalogue 2012

37

Domestic hot water tank

Casing Colour Metallic grey

Material Galvanised steel (precoated sheet metal)

Dimensions Unit HeightxIntegrated on indoor unitxWidthxDepth

mm

Weight Unit Empty kg

Tank Water volume l

Material Stainless steel (EN 1.4521)

Maximum water temperature °C

Heat exchanger Quantity

Tube material Duplex steel (EN 1.4162)

Face area m²

Internal coil volume l

› Stainless steel domestic hot water tank › The indoor unit and domestic hot water tank can be stacked to save

space, or installed next to each other, if only limited height is available › Available in 200 and 260 liters › Heat loss is reduced to a minimum thanks to the high quality insulation › At necessary intervals, the indoor unit can heat up the

water to 60°C to prevent the risk of bacteria growth › Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes

Domestic hot water tank

37

EKHTS200AC EKHTS260AC

1,590x600x695 1,590x600x695

70 78

200 260

75

1

1.56

7.5

37

EKHTS-AC

EKHTS200AC EKHTS260AC

GC_pre2_lowres.pdf 37 30/11/2011 12:30:52

Page 40: DAIKIN General Catalogue 2012

38

Domestic hot water tank

Casing Colour Dust grey (RAL7037)

Material Impact resistant polypropylene

Dimensions Unit HeightxWidthxDepth mm

Weight Unit Empty kg

Tank Water volume l

Maximum water temperature °C

Heat exchanger Domestic hot water

Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Operating pressure bar

Average specifc thermal output

W/K

Charging Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Average specifc thermal output

W/K

Auxiliary solar heating

Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Average specifc

thermal outputW/K

› Tank designed for connection with thermal solar collectors › Available in 300 and 500 liters › Large hot water storage tank to provide domestic hot water at any time › Heat loss is reduced to a minimum thanks to the high quality insulation › Space heating support possible (500l tank only)

Domestic hot water tank

38

EKHWP300A EKHWP500A

1,590x595x615 1,590x790x790

59 92

300 500

85

5.7 5.9

27.8 28.4

6

2,795 2,860

2.5 3.7

12.3 17.4

1,235 1,809

- 1.0

- 5

- 313

38

EKHWP300A

EKHWP-A

EKHWP500A

GC_pre2_lowres.pdf 38 30/11/2011 12:30:52

Page 41: DAIKIN General Catalogue 2012

39

Pump station

Mounting On side of tank

Dimensions Unit HeightxWidthxDepth mm

Thermal performance Zero loss collector efficiency η0 %

Control Type Digital temperature difference controller with plain text display

Power consumption W

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return flow sensor PTC

Feed temperature and flow sensor Voltage signal (3.5V DC)

Power supply Voltage V

› Save energy and reduce CO2 emissions with a solar

system for domestic hot water production › Pump station connectable to unpressurised solar system › Pump station and control provide the transfer of

solar heat to the domestic hot water tank

Solar connection

› Horizontal and vertical solar collector for domestic hot water production › Solar panels can produce up to 70% of the energy needed

for hot water production – a major cost saving › High efficiency collectors transfer all the short-wave solar radiation

into heat as a result of their highly selective coating › system for domestic hot water production › Easy to install on roof tiles

Solar collector

Solar collector

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Volume l

Surface Outer m²

Aperture m²

Absorber m²

Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)

Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate

Glazing Single pane safety glass, transmission +/- 92%

Allowed roof angle Min.~Max. °

Operating pressure Max. bar

Stand still temperature Max. °C

Thermal performance

Zero loss collector efficiency η0 %

Heat loss coefficient a1 W/m².K

Temperature dependence of the heat loss coefficient a2 W/m².K²

Thermal capacity kJ/K

Incident angle modifier AM at 50°

Installed position Vertical Horizontal

39

EKSRPS3

815x230x142

-

2

230

EKSH26P EKSV26P

1,300x2,000x85 2,000x1,300x85

43

2.1 1.7

2.601

2.364

2.354

15~80

6

200

78.7

4.270

0.0070

6.5

0.94

39

EKSRPS3

EKSRPS

EKSH-P

EKS(V/H)-P

EKSV-P

GC_pre2_lowres.pdf 39 30/11/2011 12:30:52

Page 42: DAIKIN General Catalogue 2012

4040

1

2

3

3Daikin Altherma Flex Type

The Daikin Altherma range is

a mix of intelligent solutions and

advanced control technologies that

provide the ultimate in controllable

comfort for residential

or commercial

buildings while respecting the

environment through reduced energy

consumption.

Heating

Cooling

Hot water

3-in-1 systemDaikin Altherma Flex Type heats, cools, and produces domestic

hot water:

› Heating: leaving water temperatures up to 80° C

› Cooling: leaving water temperatures down to 5° C

› Hot water: tank temperatures up to 75° C

Thanks to its heat recovery function, the system can heat up

the hot water tank up to 60°C with rejected heat from cooling

operation.

One or more indoor and outdoor units

Concept description

GC_pre2_lowres.pdf 40 30/11/2011 12:30:52

Page 43: DAIKIN General Catalogue 2012

41

Providing total climate control in such places as schools, hospitals, libraries, spas, gyms and hotels presents

particular challenges in that there are frequently a large number

of rooms of greatly varying sizes that need heating and cooling while, at the same time large volumes of hot water are also needed – often ‘on demand’.

The Daikin Altherma range is designed with these sorts of

challenges in mind. Each outdoor unit can be linked to up to ten

indoor units with each indoor unit being individually controlled

to enable the perfect comfort temperature to be maintained at

all times. In addition, by making integrated and optimal use of

VRV, cascade and heat pump technologies, the system efficiently

generates hot water in both heating and cooling modes.

GC_pre2_lowres.pdf 41 30/11/2011 12:30:53

Page 44: DAIKIN General Catalogue 2012

42

6kW to 9kWIndoor unit

Casing Colour Metallic grey Metallic grey

Material Precoated sheet metal Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Cooling Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-134a R-134a

Charge kg

Sound pressure level

Nom. dBA

Night quiet mode Level 1 dBA

Power supply Name V1 V1

Phase

Frequency Hz

Voltage V

Current Recommended fuses A

› High temperature application: up to 80°C without electric heater › Floor standing indoor unit up to 16 kW › Energy efficient heating and cooling system based

on air to water heat pump technology › Flexible configuration with respect to heat emitters › Low energy bills and low CO

2 emissions

› Inverter controlled scroll compressor

Daikin Altherma Flex Type

Heating & CoolingHeating only

42

EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A

705x600x695 705x600x695

92 120

-15~20 -15~20

25~80 25~80

- 10~43

- 5 ~20

-15~35 -15~35

45~75 45~75

2 2

40 / 43 42 / 43 40 / 43 42 / 43

38 38

1~ 1~

50 50

220-240 220-240

20 20

42

EKHVM(R/Y)D-A / EKHBRD-AC

EKHVM(R/Y)D-A

GC_pre2_lowres.pdf 42 30/11/2011 12:30:53

Page 45: DAIKIN General Catalogue 2012

43

Heating only - 11kW to 16kWIndoor unit

Casing Colour Metallic grey Metallic grey

Material Precoated sheet metal Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-134a R-134a

Charge kg

Sound pressure level

Nom. dBA

Night quiet mode Level 1 dBA

Power supply Name V1 Y1

Phase

Frequency Hz

Voltage V

Current Recommended fuses A

43

EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

705x600x695 705x600x695

144.25 147.25

-20 ~20 -20 ~20

25~80 25~80

-20~35 -20~35

25~80 25~80

3.2 3.2

43 / 46 45 / 46 46 / 46 43 / 43 45 / 45 46 / 46

40 43 45 40 43 45

1~ 3~

50 50

220-240 380-415

25 16

43

EKHBRD-ACV1/CY1

GC_pre2_lowres.pdf 43 30/11/2011 12:30:53

Page 46: DAIKIN General Catalogue 2012

44

› The ultimate heating solution for residential and commercial applications based on air to water heat pump technology

› Customised to meet your building’s needs: up to 10 indoor units can be connected to 1 outdoor unit

› Low energy bills and low CO2 emissions

› Easy installation and maintenance › Integrated heat recovery system

Daikin Altherma Flex Type

Heat recoveryOutdoor unit

Heating capacity Nom. kW

Cooling capacity Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Heating Min.~Max. °CWB

Domestic hot water Ambient Min.~Max. °CDB

Cooling Min.~Max. °CDB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Suction OD mm

High and low pressure gas OD mm

Piping length OU - IU Max. m

System Equivalent m

Total piping length System Actual m

Sound power level Heating Nom. dBA

Sound pressure level Heating Nom. dBA

Power supply Phase/Voltage V

(1) Condition: Ta=7°CDB/6°CWB, 100% connection ratio (2) Condition: Ta=35°CDB, 100% connection ratio

44

EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A

22.4 (1) 28 (1) 33.6 (1) 39.2 (1) 44.8 (1)

20 (2) 25 (2) 30 (2) 35 (2) 40 (2)

1,680x1,300x765

331 339

-15~20

-15~35

10~43

9.52 12.7

19.1 22.2 28.6

15.9 19.1 22.2

100

120

300

78 80 83 84

58 60 62 63

3~/380-415

44

EMRQ8-16A

EMRQ-A

GC_pre2_lowres.pdf 44 30/11/2011 12:30:53

Page 47: DAIKIN General Catalogue 2012

45

Domestic hot water tank

Casing Colour Metallic grey

Material Galvanised steel (precoated sheet metal)

Dimensions Unit HeightxIntegrated on indoor unitxWidthxDepth

mm

Weight Unit Empty kg

Tank Water volume l

Material Stainless steel (EN 1.4521)

Maximum water temperature °C

Heat exchanger Quantity

Tube material Duplex steel (EN 1.4162)

Face area m²

Internal coil volume l

› Stainless steel domestic hot water tank › The indoor unit and domestic hot water tank can be stacked to save

space, or installed next to each other, if only limited height is available › Available in 200 and 260 liters › Heat loss is reduced to a minimum thanks to the high quality insulation › At necessary intervals, the indoor unit can heat up the

water to 60°C to prevent the risk of bacteria growth › Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes

Domestic hot water tank

45

EKHTS200AC EKHTS260AC

2,010x600x695 2,285x600x695

70 78

200 260

75

1

1.56

7.5

45

EKHTS-AC

EKHTS200AC EKHTS260AC

GC_pre2_lowres.pdf 45 30/11/2011 12:30:53

Page 48: DAIKIN General Catalogue 2012

46

Heating & CoolingIndoor unit

Heating capacity Total capacity Nom. kW

Btu/h

Cooling capacity Total capacity Nom. kW

Sensible capacity Nom. kW

Power input Heating Nom. kW

Cooling Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Piping connections Drain/OD/Inlet/Outlet mm/inch

Sound pressure level

Heating Nom. dBA

Cooling Nom. dBA

Power supply Phase/Frequency/Voltage Hz/V

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (2) Heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5K.

› Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room

› Energy efficient heating and cooling system based on air source heat pump technology

› Optimum energy efficiency when connected to a Daikin Altherma low temperature system

› The indoor unit distributes air at the sound of a whisper. The noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average.

› Reduced running costs › Ideal for installation beneath a window › Weekly timer can be set to start heating or cooling

anytime on a daily or weekly basis › Indoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor unit by 3dBA › Can be installed against a wall or recessed › Powerful mode can be selected for rapid cooling; after the powerful

mode is turned off, the unit returns to the preset mode. › Titanium apatite photocatalytic air purification filter removes

airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

Heat pump convector

46

FWXV15A FWXV20A

1.5 2.0

5,100 6,800

1.2 1.7

0.98 1.4

0.013 0.015

0.013 0.015

600x700x210

15

18/G 1/2/G 1/2

19 29

19 29

1~/50/60/220-240/220

46

FWXV-A ARC452A15

FWXV-A

GC_pre2_lowres.pdf 46 30/11/2011 12:30:54

Page 49: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 47 30/11/2011 12:30:54

Page 50: DAIKIN General Catalogue 2012

48

Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling of well-being to your living space all year round. Its unobtrusive yet stylish design with a front panel that radiates additional heat, its low noise level and reduced air fl ow turn your room into a haven.

COMFORT IS KEY

The best of two

worlds united

Pure comfort and

design

radiant heat

GC_pre2_lowres.pdf 48 30/11/2011 12:30:54

Page 51: DAIKIN General Catalogue 2012

49

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

HeatingHigh/Nom./Low/ Silent operation/Radiant heat dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: full range A class energy labels › The aluminium part of the front panel of the Nexura indoor

unit has the capability of warming up, just like a traditional radiator, to add even more comfort on cold days

› The indoor unit distributes air at the sound of a whisper. The noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average.

› Comfortable vertical auto swing ensures draughtfree operation and prevents ceiling soiling

› Ideal for installation beneath a window › Can be installed against a wall or recessed › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Night set mode saves energy by preventing overcooling

or overheating during night time › Indoor/outdoor unit silent operation: “silent” buttons on the remote control

lower the operating sound of the indoor and/or outdoor unit by 3dBA each › Weekly timer can be set to start heating or cooling

anytime on a daily or weekly basis › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode. › Titanium apatite photocatalytic air purification filter removes airborne

microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit with radiant heat panel

*prEN14825 (inquiry version 2010)

49

FVXG25K FVXG35K FVXG50K

1.3/2.5 /3.0 1.4/3.5 /3.8 1.7/5.0 /5.6

1.3/3.4 /4.5 1.4/4.5 /5.0 1.7/5.8 /8.1

0.300/0.550/0.790 0.310/0.950/1.150 0.450/1.520/2.000

0.290/0.780/1.270 0.290/1.210/1.460 0.500/1.580/2.660

4.55 / 4.36 3.68 / 3.72 3.29 / 3.67

275 475 760

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5 10.6/8.9/7.3/6.0

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0 12.2/10.0/7.8/6.8

54 55 56

55 56 58

38/32/26/23 39/33/27/24 44/40/36/32

39/32/26/22/19 40/33/27/23/19 46/40/34/30/20

6.35 / 9.5 / 18 6.35 / 12.7 / 18

1~ / 50 / 220-240

RXG25K RXG35K RXG50K

550x765x285 735x825x300

34 48

33.5/30.1 36.0/30.1 50.9/48.9

28.3/25.6 45/43.1

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-15~20

15 20

-

1~ / 50 / 220-240

49

FVXG25,35,50K RXG25,35K ARC466A2

FVXG-K / RXG-K

GC_pre2_lowres.pdf 49 30/11/2011 12:30:55

Page 52: DAIKIN General Catalogue 2012

50

› Optimised heating solution for your home › Extended operation range for heating down to -20°C › Energy efficient units: full range A class energy labels › Remarkable blend of iconic design and engineering excellence with

an elegant finish in brushed aluminium or matt crystal white › Energy saving during standby mode: reduces current

consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode.

› Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body

› Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.

› Indoor/outdoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor/outdoor unit by 3dBA

› Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Night set mode saves energy by preventing overcooling or overheating during night time

› The infrared remote control is user friendly and equipped with a timer function that enables you to programme the unit to start or stop at your desired time.

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

Designed for colder climates

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating

Casing Colour Matt crystal white Brushed aluminium

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

*Note: grey cells contain preliminary data

50

FTXG25JW FTXG35JW *FTXG25JA *FTXG35JA

1.3/2.5/3.0 1.4/3.5/3.8 1.3/2.5 (3)/3.0 1.4/3.5 (3)/3.8

1.3/3.4/4.5 1.4/4.5/5.0 1.3/3.4 (4)/4.5 1.4/4.5 (4)/5.0

0.56 0.89 0.56 0.89

0.78 1.11 0.78 1.11

4.46/4.36 3.93/4.04 4.46/4.36 3.93/4.04

280 445 280 445

A/A A/A

295x915x155 295x915x155

11 11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6

54 58 54 58

55 58 55 58

38/32/25/22 42/34/26/23 38/32/25/22 42/34/26/23

39/34/28/25 42/36/29/26 39/34/28/25 42/36/29/26

R-410A R-410A

6.35/9.5 6.35/9.5

550x765x285 550x765x285

34 34

33.5/30.1 36.0/30.1 33.5/30.1 36.0/30.1

28.3/25.6 30.2/25.6 28.3/25.6 30.2/25.6

-/61 -/63 -/61 -/63

46/43 48/44 46/43 48/44

47/44 48/45 47/44 48/45

-10~46 -10~46

-20~20 -20~20

15 15

- -

1~ / 50 / 220-230-240 1~ / 50 / 220-230-240

50

FTXG25,35,50J RXLG25,35K ARC466A1

FTXG-J / RXLG-K

RXLG25K RXLG35K RXLG25K RXLG35K

emura

GC_pre2_lowres.pdf 50 30/11/2011 12:30:55

Page 53: DAIKIN General Catalogue 2012

51

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air fl ow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid / Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air fl ow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level diff erence IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range for heating down to -20°C › Energy effi cient units: full range A class energy labels › The aluminium part of the front panel of the Nexura indoor

unit has the capability of warming up, just like a traditional radiator, to add even more comfort on cold days

› Ideal for installation beneath a window › Can be installed against a wall or recessed › Comfortable vertical auto swing ensures draughtfree

operation and prevents ceiling soiling › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Night set mode saves energy by preventing overcooling

or overheating during night time › The indoor unit distributes air at the sound of a whisper. The

noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average.

› Indoor/outdoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dBA each

› Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off , the unit returns to the preset mode.

› Titanium apatite photocatalytic air purifi cation fi lter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit with radiant heat panel

Designed for colder climates

51

FVXG25K FVXG35K

1.3/2.5 /3.0 1.4/3.5 /3.8

1.3/3.4 /4.5 1.4/4.5 /5.0

0.55 0.95

0.78 1.21

4.55 / 4.36 3.68 / 3.72

275 476

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0

54 55

55 56

38/32/26/23 39/33/27/24

39/32/26/22 40/33/27/23

6.35 / 9.5

1~ / 50 / 220-240

RXLG25K RXLG35K

550x765x285

34

33.5/30.1 36.0/30.1

28.3/25.6 30.2/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

51

FVXG25,35K RXLG25,35K ARC466A2

FVXG-K / RXLG-K

radiant heat

GC_pre2_lowres.pdf 51 30/11/2011 12:30:55

Page 54: DAIKIN General Catalogue 2012

52

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range down to -20°C in heating › 2 area intelligent eye: air flow is sent to a zone other than where the person

is located at that moment; if two people are detected in the room, the air flow is projected away from the occupants; if no people are detected, the unit will automatically switch over to the energy-efficient setting

› Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body

› 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces

› ECONO mode decreases power consumption so that other appliances that need large power consumption can be used

› Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode

› Night set mode saves energy by preventing overcooling or overheating during night time

› Indoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor unit by 3dBA

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

Designed for colder climates

52

FTXS20J FTXS25J FTXS35J

1.3/2.0 /2.8 1.3/2.5 /3.2 1.4/3.5 /4.0

1.3/2.7 /4.3 1.3/3.3 /4.7 1.4/4.0 /5.2

0.45 0.54 0.86

0.61 0.71 0.95

4.44 / 4.43 4.67 / 4.65 4.07 / 4.21

225 268 430

295x800x215

9 10

9.4/7.4/5.5/4.1 10.8/7.9/5.2/3.7 11.4/8.7/5.8/4.4

9.9/8.2/6.6/6.2 11.9/9.1/6.4/5.9 12.4/9.5/6.8/6.0

54 57 61

54 58 61

38/32/25/22 41/33/25/22 45/37/29/23

38/33/28/25 42/35/28/25 45/39/29/26

R-410A

6.35 / 9.5

1~ / 50 / 220-240

RXL20J RXL25J RXL35J

550x765x285

32 34

36.2/32.7 33.5/30.1 36.0/30.1

30.6/28.5 28.3/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

52

FTXS20,25,35J RXL20,25,35J ARC452A3

FTXS-J / RXL-J

GC_pre2_lowres.pdf 52 30/11/2011 12:30:55

Page 55: DAIKIN General Catalogue 2012

53

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High. dBA

Heating High. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range down to -20°C in heating › Ideal for installation beneath a window › Can be installed against a wall or recessed › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › Energy saving during standby mode: reduces current consumption by about

80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode

› Whisper quiet operation: down to 23dBA sound pressure level › Indoor/outdoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor/outdoor unit by 3dBA › Night set mode saves energy by preventing overcooling

or overheating during night time › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode › Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis › Titanium apatite photocatalytic air purification filter removes airborne microscopic

particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit

Designed for colder climates

53

FVXS25F FVXS35F

1.3/2.5 /3.0 1.4/3.5 /3.8

1.3/3.4 /4.5 1.4/4.5 /5.0

0.57 0.81

0.99 1.22

4.39 / 3.43 4.30 / 3.69

285 407

600x700x210

14

8.2/6.5/4.8/4.1 8.5/6.7/4.9/4.5

8.8/6.9/5.0/4.4 9.4/7.3/5.2/4.7

54 55

54 55

38/32/26/23 39/33/27/24

38/32/26/23 39/33/27/24

6.35 / 9.5

RXL25J RXL35J

550x765x285

34

33.5/30.1 36.0/30.1

28.3/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

53

FVXS25,35F RXL25,35J ARC452A1

FVXS-F / RXL-J

GC_pre2_lowres.pdf 53 30/11/2011 12:30:56

Page 56: DAIKIN General Catalogue 2012

54

› Energy efficient heating system based on air source heat pump technology › Low energy consumption and low CO

2 emmisions

› The ability to control each conditioned zone individually keeps VRV system running costs to an absolute minimum

› Temperature control, fresh air provision and Biddle air curtains all integrated in a single system

› Perfect comfort: faster response than traditional heating systems and a constant indoor temperature

› Wide range of indoor units: 14 different models › Easy management of the yearly energy cost thanks

to a wide range of control possibilities › Spread your installation cost by phased installation › No need for fuel storage tanks or pumps › Wide outdoor unit range: from 25 to 170 kW › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Easy compliance with F-gas regulation thanks to

automated refrigerant containment check › Compact size leaves maximum floorspace › Fits any building with either outdoor or indoor installation

possible (high external static pressure up to 78.4Pa) › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Wide piping flexibility: maximum piping length:

165m, total piping length: 1,000m

VRVIII heating only

5454

RXHQ-P9

RXHQ44-46-48P

GC_pre2_lowres.pdf 54 30/11/2011 12:30:56

Page 57: DAIKIN General Catalogue 2012

Heating onlyOutdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index

connection

Min.

Nom.

Max.

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound pressure level Heating Nom. dBA

Operation range Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping

connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Outdoor unit module 2 RXHQ12P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index connection

Min.

Nom.

Max.

Sound pressure level Heating Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Outdoor unit module 2 RXHQ12P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index connection

Min.

Nom.

Max.

Sound pressure level Heating Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

55

RXHQ8P9 RXHQ10P9 RXHQ12P9 RXHQ14P9 RXHQ16P9 RXHQ18P9

8 10 12 14 16 18

25.0 31.5 37.5 45.0 50.0 56.5

5.56 7.70 9.44 11.30 12.90 15.30

4.50 4.09 3.97 3.98 3.88 3.69

17 21 26 30 34 39

100 125 150 175 200 225

200 250 300 350 400 450

260 325 390 455 520 585

1,680x930x765 1,680x1,240x765

187 240 316 324

61 64 67

-20.0~15.0

9.52 12.7 15.9

19.1 22.2 28.6

165

1,000

3N~/50/400

25 40

RXHQ20P9 RXHQ22P9 RXHQ24P9 RXHQ26P9 RXHQ28P9 RXHQ30P9 RXHQ32P9 RXHQ34P9 RXHQ36P9

20 22 24 26 28 30 32 34 36

62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00

14.95 17.08 18.89 20.69 22.98 24.67 26.63 28.23 30.62

4.18 4.04 3.97 3.94 3.83 3.81 3.83 3.79 3.69

43 47 52 56 60 64

250 275 300 325 350 375 400 425 450

500 550 600 650 700 750 800 850 900

650 715 780 845 910 975 1,040 1,105 1,170

66 67 68 69 70

15.9 19.1

28.6 34.9 41.3

165

1,000

3N~/50/400

50 63 80

RXHQ38P9 RXHQ40P9 RXHQ42P9 RXHQ44P9 RXHQ46P9 RXHQ48P9 RXHQ50P9 RXHQ52P9 RXHQ54P9

38 40 42 44 46 48 50 52 54

119.00 126.00 132.00 138.00 145.00 151.00 158.00 163.00 170.00

30.13 32.39 34.20 35.94 38.26 39.95 41.91 43.47 45.95

3.95 3.89 3.86 3.84 3.79 3.78 3.77 3.75 3.70

64

475 500 525 550 575 600 625 650 675

950 1,000 1,050 1,100 1,150 1,200 1,250 1,300 1,350

1,235 1,300 1,365 1,430 1,495 1,560 1,625 1,690 1,755

69 70 71 72

19.1

41.3

165

1,000

3N~/50/400

100 125

55

Power input - 50Hz

Power input - 50Hz

Power input - 50Hz

55

GC_pre2_lowres.pdf 55 30/11/2011 12:30:56

Page 58: DAIKIN General Catalogue 2012

56

Heating & CoolingOutdoor system

System Outdoor unit module 1 RTSQ10PY1 RTSQ14PY1 RTSQ16PY1 RTSQ8PY1

Outdoor unit module 2 RTSQ12PY1

Function unit BTSQ20PY1

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Max./Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Oil equalizing OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (2) Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB,6°CWB;

equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (3) Heating: Indoor temp. 20°CDB; outdoor temp. -10°CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m;

combined indoor unit: FXFQ50P x 5 units

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

› First system in the industry developed for heating operation in low ambient conditions, making it suitable for single source heating

› Extended operation range down to -25°C in heatingHEATING

20

10

0

-5

-10

-15

-20

-25

30

VRV III-C

+15.5 °CWB

-25 °CWB

-20 °CWB

VRV III

+15.5 °CWB

› High COP values at low ambients thanks using the two stage compression technology (COP values of 3.0 and more at -10°C)

› Improved comfort thanks to shorter defrost time › Shorter heat up time compared to standard VRVIII heat pump › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Connectable to all VRV indoor units, ventilation and control systems

VRVIII heat pump, optimised for heating

56

RTSYQ10P RTSYQ14P RTSYQ16P RTSYQ20P

-

10 14 16 20

28.0 (1) 40.0 (1) 45.0 (1) 55.9 (1)

31.50 (2) / 28.0 (3) 45.0 (2) / 40.0 (3) 50.0 (2) / 45.0 (3) 62.5 (2) / 56.0 (3)

7.90 12.6 14.9 15.4

7.70 11.3 12.9 15.3

3.54 3.17 3.02 3.63

4.09 3.98 3.88 4.01

21 30 34 43

62/60 63/61 65/63

9.52 12.7 15.9

22.2 28.6

- 19.1

165

500

3~/50/380-415

25 35 40 50

RTSQ8P RTSQ12P RTSQ14P RTSQ16P RTSQ20P BTSQ10P

1,680x930x765 1,680x930x765 1,570x460x765 1,680x930x765

205 257 338 344 110 257

-5 ~ 46

-25 ~ 15.5

3~/50/380-415

25 35 40 20 25

56

RTSYQ14-16P

RTSYQ-P

GC_pre2_lowres.pdf 56 30/11/2011 12:30:56

Page 59: DAIKIN General Catalogue 2012

57

Heat recoveryHeating & CoolingOutdoor unit

System Outdoor unit module 1 RWEYQ8PY1R RWEYQ10PY1R

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Inlet water temperature

Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Water Inlet/Outlet PT1 1/4B internal thread/PT1 1/4B internal thread

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

› Reduced CO2 emmisions thanks to the use of geothermal

energy as a renewable energy source › No need for an external heating or cooling source › Extended operation range (inlet water

temperature) down to -10°C in heating › High heating efficiency at low water entering temperatures (eg.

3.44 COP at -10°C entering water temperature for an 8HP unit) › Suitable for multi-storey and large buildings because of

the hardly unlimited possibilities of water piping › Simultaneous cooling and heating operation from one system › ‘High sensible mode’: allows the VRV system to work with

increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort

› 2-stage heat recovery: first stage between indoor units, second stage between outdoor units thanks to the storage of energy in the water circuit

› Heat recovery systems offer the highest comfort, including individual change-over of each BS box without disruption of other BS boxes

› Wide range of indoor units: 14 different models › Compact design (stacked configuration possible) › Connectable to current Daikin control systems: DS-net, Intelligent

Touch Controller, Intelligent Manager, BACnet Gateway, DMS-iF

VRVIII water cooled, geothermal series

Heat pump operation

57

RWEYQ8PR RWEYQ10PR

8 10

22.4 26.1

25.0 31.5

4.58 6.30

4.30 6.20

4.89 4.14

5.81 5.08

17 21

1,000x780x550

149 150

-

50 51

10~45

10~45

9.52

19.1 (1) 22.2 (1)

15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3)

120

300

3~/50/380-415

25

57

RWEYQ10PR

RWEYQ-PR

GC_pre2_lowres.pdf 57 30/11/2011 12:30:57

Page 60: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 58 30/11/2011 12:30:57

Page 61: DAIKIN General Catalogue 2012

59

AIR CONDITIONING

Residential applications 61

Light commercial applications - Sky Air 115

Medium to large commercial applications - VRV 161

Ventilation & Biddle Air Curtains 207

Marine types 219

With air conditioning, you treat the air in a room to obtain an ideal temperature, purity,

ventilation and humidity. Air conditioning does much more than just cool the space you live

and work in. Enjoy perfect Daikin comfort all year round.

GC_pre2_lowres.pdf 59 30/11/2011 12:30:58

Page 62: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 60 30/11/2011 12:30:58

Page 63: DAIKIN General Catalogue 2012

61

RESIDENTIAL APPLICATIONS

Benefi ts overview 62

PAIR APPLICATIONS

Wall mounted units 67

FTXR-E / RXR-E 67

FTXG-J / RXG-K 69

FTXS-K/J/G / RXS-K/J/G 71

FTX-JV/GV / RX-JV/GV 72

Concealed ceiling units 73

FDXS-E/C / RXS-K/J/F 73

Floor standing units 74

FVXG-K / RXG-K 75

FVXS-F / RXS-K/J 76

Flexi type unit 77

FLXS-B / RXS-K/J 77

Designed for the cold 78

FTXG-J / RXLG-K 78

FVXG-K / RXLG-K 79

FTXS-J / RXL-J 80

FVXS-F / RXL-J 81

MULTI MODEL APPLICATIONS 82

MXU-G 82

MXS-E/F/G/H/K 88

RXYSQ-P8V1 123

NEW

NEW

NEW

NEW

NEW

NEW

NEW

For more information on Options & Control Systems, please refer to page 346 of this catalogue.

GC_pre2_lowres.pdf 61 30/11/2011 12:30:58

Page 64: DAIKIN General Catalogue 2012

We care icons Comfort

Wal

l mo

un

ted

un

it

FTXR-E

� � � � � � � � �

FTXG-J

� � � � � � � � � � � � RXG-K

CTXU-G

� � � � � � � � � � MXU-G

FTXS-K

� � � � � � � � � � � �

CTXS-K

� � � � � � � � � � � �

FTXS-J

� � � � � � � � � � � RXS-J

FTXS-G

� � � � � � � � � RXS-G

FTX-JV

� � � � � � � � � � �

FTX-GV

� � � � � � � � � RX-GV

Preliminary info

For explanation on the benefits, see flap in the backcover of this catalogue.

Benefits overview - Split

��������

62

GC_pre2_lowres.pdf 62 30/11/2011 12:30:58

Page 65: DAIKIN General Catalogue 2012

Air flow

� � � � 5 � � � � � � � � �

� � 5 � � � � � � � � � � � �

� � � � 5 � � � � � � � � � �

� � 5 � � � � � � � � � � � �

� � 5 � � � � � � � � � � � �

� � � � 5 � � � � � � � � � � � �

� � � � 5 � � � � � � � � � � � �

� � 5 � � � � � � � �

� � � � 5 � � � � � � � � �

Humidity control Air treatment Remote control & timer Other funtions

63

GC_pre2_lowres.pdf 63 30/11/2011 12:30:59

Page 66: DAIKIN General Catalogue 2012

Benefi ts overview - SplitFl

oo

r st

and

ing

un

it

FVXG-K

� � � � � � � � � � RXG-K

FVXS-F

� � � � � � � � � RXS-K

Co

nce

ale

d c

eili

ng

un

it

FDXS-E

� � � � � � � �RXS-

K/J

FDXS-C

� � � � � � � � RXS-J/F

FDBQ-B

� � �

Fle

xi t

ype

un

it FLXS-B

� � � � � � � � RXS-K

For explanation on the benefi ts, see fl ap in the backcover of this catalogue.

We care icons Comfort

64

��������

GC_pre2_lowres.pdf 64 30/11/2011 12:30:59

Page 67: DAIKIN General Catalogue 2012

� � � � � � � � � � � � � �

� � 5 � � � � � � � � � �

� 5 � � � � � � � � � �

� 5 � � � � � � � � � �

2 � � � � � � � �

� � 5 � � � � � � � � � �

Air flow Humidity control Air treatment Remote control & timer Other funtions

65

GC_pre2_lowres.pdf 65 30/11/2011 12:30:59

Page 68: DAIKIN General Catalogue 2012

66

Good Design Award

Ururu Sarara

A UNIQUE COMBINATION OF HUMIDIFICATION,

DEHUMIDIFICATION, VENTILATION AND AIR PURIFICATION

Good temperature control is not all that is needed for a comfortable

indoor climate. Precision control of humidity and ventilation of the

room is essential. Thanks to the Ururu Sarara, you can humidify,

dehumidify, ventilate and purify. The unit is fi tted with fi lters

that also fi lter dust, pollen and smoke. You can also adjust the air

purifi cation to meet your specifi c needs. Thanks to the ventilation

system, contaminated indoor air in a space is replaced with fresh

outdoor air.

URURU HUMIDIFICATION:

PLEASANT, EVEN DURING HEATING

The Ururu humidifi cation system absorbs moisture from the outdoor air

and transports it to the indoor unit, quickly and effi ciently humidifying

the room. Thanks to the perfect combination of humidifi cation and air

conditioning, your room heats evenly.

SARARA DEHUMIDIFICATION:

FEEL THE DIFFERENCE!

When humidity is too high, the Sarara dehumidication system ensures

that it is lowered without changing the room temperature. That is ideal

for you, because lower humidity means you feel more comfortable.

› The ideal humidity › Comfortable air fl ow › Powerful air purifi cation

› Stylish design (good design award) › Energy saving and high effi ciency: one unit of energy is

converted into more than fi ve units of energy for cooling or heating

Ururu

Sarara

Temp.: 22°C Temp.: 22°C

Temp.: 25°C Temp.: 25°C

Humidity: 20%Cold feeling

Humidity: 50%Comfortable feeling

Humidity: 80%Hot humid feeling

Humidity: 50%Comfortable feeling

VENTILATION & HUMIDITY CONTROL - HEATING & COOLING

GC_pre2_lowres.pdf 66 30/11/2011 12:30:59

Page 69: DAIKIN General Catalogue 2012

67

Heating & CoolingIndoor units FTXR28E FTXR42E FTXR50E

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor units RXR28E RXR42E RXR50E

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Piping length Max. OU - IU m

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: full range A class energy labels (5.00 EER; 5.14 COP) › URURU humidification: maintains a comfortable humidity

level without any separate water supply › SARARA dehumidification: maintains a comfortable and fresh indoor environment

by removing moisture from the air without lowering the temperature › Powerful ventilation refreshes the room within 2 hours › Powerful air purification increases indoor air quality with Daikin Flash

Streamer technology › Good design award: unique evaluation criterion for industrial design in Japan › Night set mode saves energy by preventing

overcooling or overheating during night time › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode. › Comfort mode guarantees draught free operation by preventing

that warm or cold air is directly blown on to the body › Whisper quiet operation: down to 23dBA sound pressure level › Indoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor unit by 3dBA › Titanium apatite photocatalytic air purification filter absorbs microscopic

particles, decomposes odours and even deactivates bacteria and viruses › 3-D air flow combines vertical and horizontal auto swing to circulate a

stream of warm or cool air right to the corners of even large spaces › Other features: moisturizing operation mode, breeze cooling

air flow, comfort sleep operation, mould shock operation › Online controller (optional): control your indoor unit from any

location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

*prEN14825 (inquiry version 2010)

67

1.55/2.8/3.6 1.55/4.2/4.60 1.55/5.0/5.50

1.30/3.6/5.00 1.30/5.1/5.6 1.30/6.0/6.20

0.250/0.560/0.800 0.260/1.050/1.320 0.26/1.46/1.8

0.220/0.700/1.410 0.220/1.180/1.600 0.23/1.51/1.77

5.00 / 5.14 4.00 / 4.32 3.42 / 3.97

280 525 730

305x890x209

14

11.1/8.8/6.5/5.7 12.4/9.6/6.8/6.0 13.3/10.3/7.3/6.5

12.4/9.8/7.3/6.5 12.9/10.2/7.7/6.8 14.0/11.1/8.3/7.3

55 58 60

57 58 60

39/33/26/23 42/35/27/24 44/37/29/26

41/35/28/25 42/36/29/26 44/38/31/28

6.35 / 9.52 / 18

1~ / 50 / 220-240

693x795x285

48

33.8 36.2

31.4 31.9 34.3

60 62

46 48

46 48 50

-10~43

-20~18

10

8

-

1~ / 50 / 220-240

67

FTXR28,42,50E RXR28,42,50E ARC447A

FTXR-E / RXR-E

GC_pre2_lowres.pdf 67 30/11/2011 12:30:59

Page 70: DAIKIN General Catalogue 2012

68

The Daikin Emura wall mounted air conditioning unit from Daikin is a remarkable blend of iconic design and engineering excellence. Its ultra-thin profi le and elegant fi nish in matt crystal white or brushed aluminium mean it will complement any interior. And those good looks certainly don’t compromise its performance. Designed in Europe for European climates, you can rely on the Daikin Emura to deliver pleasant temperatures and consistent humidity levels, whatever the season.

It is designed to be mounted high on the wall, for optimum air distribution and whisper-quiet operation. And it is as easy to operate as it is to install and maintain. Just as importantly, its ‘A’ rating for energy effi ciency will make it as attractive to the cost-conscious as the style-conscious. The Daikin Emura represents a perfect marriage of style and substance, of form and function, of intelligent heating and effi cient cooling.

Daikin Emura

FORM.

FUNCTION.

REDEFINED.

GC_pre2_lowres.pdf 68 30/11/2011 12:30:59

Page 71: DAIKIN General Catalogue 2012

69

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A A/A

Casing Colour Matt crystal white Brushed aluminium

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: full range A class energy labels › Remarkable blend of iconic design and engineering excellence with

an elegant finish in brushed aluminium or matt crystal white › Energy saving during standby mode: reduces current

consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode.

› Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body

› Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.

› Indoor/outdoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor/outdoor unit by 3dBA

› Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Night set mode saves energy by preventing overcooling or overheating during night time

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.

› The infrared remote control is user friendly and equipped with a timer function that enables you to programme the unit to start or stop at your desired time.

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

*prEN14825 (inquiry version 2010)

69

FTXG25JW FTXG35JW FTXG50JW FTXG25JA FTXG35JA FTXG50JA

1.3/2.5/3.0 1.4/3.5/3.8 1.7/5.0/5.3 1.3/2.5/3.0 1.4/3.5/3.8 1.7/5.0/5.3

1.3/3.4/4.5 1.4/4.0/5.0 1.7/5.8/6.5 1.3/3.4/4.5 1.4/4.0/5.0 1.7/5.8/6.5

-/0.56/- -/0.89/- 0.450/1.560/1.880 -/0.56/- -/0.89/- 0.450/1.560/1.880

-/0.78/- -/0.99/- 0.520/1.600/2.500 -/0.78/- -/0.99/- 0.520/1.600/2.500

4.46 / 4.36 3.93 / 4.04 3.21 / 3.63 4.46 / 4.36 3.93 / 4.04 3.21 / 3.63

280 445 780 280 445 780

295x915x155 295x915x155

11 11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1 9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1

54 58 60 54 58 60

55 58 60 55 58 60

38/32/25/22 42/34/26/23 44/40/35/32 38/32/25/22 42/34/26/23 44/40/35/32

39/34/28/25 42/36/29/26 44/40/35/32 39/34/28/25 42/36/29/26 44/40/35/32

6.35 / 9.5 / 18.0 6.35 / 12.7 / 18.0 6.35 / 9.5 / 18.0 6.35 / 12.7 / 18.0

RXG25K RXG35K RXG50K

550x765x285 735x825x300

34 48

33.5/30.1 36.0/30.1 50.9/48.9

28.3/25.6 45/43.1

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-15~20

15 20

-

1~ / 50 / 220-240

69

FTXG25,35,50J RXG25,35K ARC466A1

FTXG-J- / RXG-K

emura

GC_pre2_lowres.pdf 69 30/11/2011 12:31:00

Page 72: DAIKIN General Catalogue 2012

70

FTXS-K_CTXS-K

Optimal design and comfort

Integrating design › Discreet, modern design. Its smooth curve blends beautifully

with the wall resulting in an unobtrusive presence that matches

all interior décors.

› High quality matt crystal white finish.

› New remote controller design, also in high quality

matt white finish to give a perfect match with the indoor unit.

Top performance Full range inverter A label, equipped with energy saving features such as the intelligent eye and the weekly timer.

› Today, many bedrooms are smaller than 20 m2 and are

becoming even smaller in new construction buildings. Thanks

to the new 15 class, it is possible to deliver the right comfort even in the smallest spaces of the house.

› Also thanks to this 15 class unit, capacity of the multi outdoor

unit can be distributed in a more flexible way to adapt to modern house configurations. The

allocation of the right capacity to smaller bedrooms releases

capacity for the increasingly larger living areas: walls

are often removed, several functions combined into one

(kitchen, dining room, living room, study room, etc.).

› Additionally, insulation of houses is improving in order to

reduce the demand for cooling and heating, and consequently,

energy consumption. The new 15 class responds to the new capacity requirements of the smallest rooms

in the house and allows optimal distribution of capacity of

new 3-port 40 multi outdoor.

Oh so quiet In bedrooms and small spaces, silence becomes even more

important than in living areas. Daikin’s new wall mounted models

go almost unnoticed in operation.

for bedrooms and

The right indoor for the right room

other small spaces

GC_pre2_lowres.pdf 70 30/11/2011 12:31:00

Page 73: DAIKIN General Catalogue 2012

71

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Only available in multi model application

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A B/B B/C

Casing Colour White White White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Only available in multi model application

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type

Piping connections

Level difference IU - OU Max. mm

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

Wall mounted unit

*prEN14825 (inquiry version 2010)

› Energy efficient units: up to A class energy labels

› FTXS-K models are especially designed for small or well-insulated rooms. › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Energy saving during standby mode: reduces current consumption by about

80% when operating In standby. If no people are detected for more than 20

minutes, the system will automatically switch to the current-saving mode.

› 3-D air flow combines vertical and horizontal auto swing to circulate a stream

of warm or cool air right to the corners of even large spaces (FTXS-J/G) › Comfort mode guarantees draught free operation by preventing

that warm or cold air is directly blown on to the body

› 2 area intelligent eye: air flow is sent to the area in a room

where no person is detected (FTXS-J/G) › Movement sensor saves power consumption in unoccupied rooms:

when the room is empty, the unit switches to economy mode after

20 minutes and restarts when a person enters the room (FTXS-K) › Whisper quiet in operation: the operating of the unit can hardly be

heard. The sound pressure level goes down to 19dBA! (FTXS-K) › Indoor/outdoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor/outdoor unit by 3dBA

› Titanium apatite photocatalytic air purification filter removes airborne microscopic

particles, powerfully decomposes odours and helps to prevent the propagation

of bacteria, viruses, microbes to ensure a steady supply of clean air

› Night set mode saves energy by preventing overcooling

or overheating during night time › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode.

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

71

CTXS15K CTXS35K FTXS20K FTXS25K FTXS25J FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G

1.3/2.0/2.8 1.3/2.5/3.2 1.3/2.5 /3.2 1.4/3.5 /4.0 1.7/4.2 /5.0 1.7/5.0 /5.3 1.7/6.0 /6.7 2.3/7.1 /8.5

1.3/2.5/4.3 1.3/2.8/4.7 1.3/3.3 /4.7 1.4/4.0 /5.2 1.7/5.4 /6.0 1.7/5.8 /6.5 1.7/7.0 /8.0 2.3/8.2 /10.2

0.32/0.43/0.76 0.32/0.57/1.00 0.320/0.535/0.810 0.350/0.860/1.190 0.440/1.210/2.330 0.440/1.460/1.810 -/1.99/- -/2.35/-

0.31/0.55/1.12 0.31/0.62/1.41 0.310/0.710/1.290 0.340/0.950/1.460 0.400/1.450/1.980 0.400/1.530/2.000 -/2.04/- -/2.55/-

4.65 / 4.55 4.39 / 4.52 4.67 / 4.65 4.07 / 4.21 3.47 / 3.72 3.42 / 3.79 3.02 / 3.43 3.02 / 3.22

- 268 430 605 730 995 1,175

A/A

289x780x215 289x780x215 295x800x215 290x1,050x250

8 8 9 10 12

7.9/6.3/4.7/3.9 9.0/7.5/6.0/4.3 8.8/6.7/4.7/3.9 9.1/7.0/5.0/3.9 10.8/7.9/5.2/3.7 11.4/8.7/5.8/4.4 11.3/9.0/6.8/5.9 11.6/9.2/7.0/6.0 16.0/13.5/11.3/10.1 17.2/14.5/11.5/10.5

9.2/7.2/5.2/3.9 10.1/8.1/6.3/4.3 9.5/7.8/6.0/4.3 10.0/8.0/6.0/4.3 11.9/9.1/6.4/5.9 12.4/9.5/6.8/6.0 12.2/9.7/7.3/6.4 12.1/9.8/7.6/6.7 17.2/14.9/12.6/11.3 19.5/16.7/14.2/12.6

53 58 56 57 57 61 62 61 62

54 57 56 57 58 61 63 60 62

37/31/25/21 42/35/28/21 40/32/24/19 41/33/25/19 41/33/25/22 45/37/29/23 45/39/33/30 46/40/34/31 45/41/36/33 46/42/37/34

38/33/28/21 41/36/30/21 40/34/27/19 41/34/27/19 42/35/28/25 45/39/29/26 45/39/33/30 47/41/34/31 44/40/35/32 46/42/37/34

R-410A R-410A R-410A

6.35/9.52/18.0 6.35/9.52/18.0 6.35 / 9.52 / 18.0 6.35 / 12.7 / 18.0 6.35 / 15.9 / 18.0

1~ / 50 / 220-240 1~ / 50 / 220-240

RXS20K RXS25K RXS25J RXS35J RXS42J RXS50J RXS60F RXS71F

550x765x285 550x765x285 735x825x300 770x900x320

34 34 39 48 71

33.5/- 33.5/30.1 36.0/30.1 37.3/30.6 50.9/48.9 50.9/42.4 54.5/57.1

28.3/- 28.3/25.6 31.3/27.2 45.0/43.1 46.3/42.4 52.5/46.0

-/61 -/61 -/63 -/66

46/43 46/43 48/44 49/46 52/49

47/44 47/44 48/45 49/46 52/49

-10~46 -10~46

-15~18 -15~18

R-410A R-410A

15 15 30 20

- -

1~ / 50 / 220-240 1~ / 50 / 220-240

71

FTXS-K/J/G / RXS-K/J/F

ARC466A1FTXS20,25K / CTXS15,35K RXS25,35K

GC_pre2_lowres.pdf 71 30/11/2011 12:31:00

Page 74: DAIKIN General Catalogue 2012

72

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A B/B B/C

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy saving during standby mode: reduction of energy from 10W to 2W › Energy efficient units: up to class A energy labels › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Night set mode saves energy by preventing

overcooling or overheating during night time › Comfort mode guarantees draught free operation by preventing

that warm or cold air is directly blown on to the body › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode. › Whisper quiet operation: down to 22dBA sound pressure level › Indoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor unit by 3dBA › Titanium apatite photocatalytic air purification filter absorbs microscopic

particles, decomposes odours and even deactivates bacteria and viruses › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › Online controller (optional): control your indoor unit from any

location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

72

FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GV

1.3/2.0/2.6 1.3/2.5/3.0 1.3/3.3/3.8 1.7/5.0/6.0 1.7/6.0/6.7 2.3/7.1/8.5

1.3/2.5/3.5 1.3/2.8/4.0 1.3/3.5/4.8 1.7/5.8/7.7 1.7/7.0/8.0 2.3/8.2/10.2

-/0.55/- -/0.73/- -/0.98/- 0.44/1.55/2.08 0.44/1.99/2.40 0.57/2.35/3.20

-/0.59/- -/0.69/- -/0.93/- 0.40/1.60/2.53 0.40/2.04/2.81 0.52/2.55/3.82

3.64 / 4.24 3.42 / 4.06 3.37 / 3.76 3.23 / 3.63 3.02 / 3.43 3.02 / 3.22

275 365 490 775 995 1,175

283x770x198 290x1,050x238

7 12

9.1/7.4/5.9/4.7 9.2/7.6/6.0/4.8 9.3/7.7/6.1/4.9 14.7/12.4/10.3/9.5 16.2/13.6/11.4/10.2 17.4/14.6/11.6/10.6

9.4/7.8/6.3/5.5 9.7/8.0/6.3/5.5 10.1/8.4/6.7/5.7 16.1/13.9/11.5/10.2 17.4/15.1/12.7/11.4 19.7/16.9/14.3/12.7

55 56 57 59 61 62

55 56 57 58 60 62

39/33/25/22 40/33/26/22 41/34/27/23 43/39/34/31 45/41/36/33 46/42/37/34

39/34/28/25 40/34/28/25 41/35/29/26 42/38/33/30 44/40/35/32 46/42/37/34

6.35/9.52/18.0 6.35/12.7/18.0 6.35/15.9/18.0

RX20JV RX25JV RX35JV RX50GV RX60GV RX71GV

550x658x275 735x825x300 770x900x320

28 30 48 71

-/29.2/- -/27.6/- 48.9/-/41.7 50.9/-/42.4 54.5/-/46.0

-/26.2/- -/24.5/- 45.0/-/41.7 46.3/-/42.4 46.0/-/46.0

60 62 61 63 66

46/- 48/- 47/44 49/46 52/49

47/- 48/- 48/45 49/46 52/49

10~46 -10~46

-15~20 -15~18

12 20

-

1~ / 50 / 220-240

72

FTX20,25,35JV RX20,25,35JV ARC433A8

FTX-JV/GV / RX-JV/GV

GC_pre2_lowres.pdf 72 30/11/2011 12:31:00

Page 75: DAIKIN General Catalogue 2012

73

› Energy efficient units: up to class A energy labels › Compact dimensions, can easily be mounted

in a ceiling void of only 240mm › Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible › Medium external static pressure facilitates unit use

with flexible ducts of varying lengths › Home leave operation maintains the indoor temperature at your

specified comfort level during absence, thus saving energy › Night set mode saves energy by preventing

overcooling or overheating during night time › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode. › Whisper quiet operation: down to 29dBA sound pressure level › Indoor/outdoor unit silent operation: “silent” buttons

on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dBA each

› Standard air filter removes airborne dust particles to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Slim concealed ceiling unit

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B B/C B/D

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Fan - External static pressure Nom. Pa

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

*Note: grey cells contain preliminary data

73

*FDXS25E FDXS35E FDXS50C FDXS60C

-/2.40/- -/3.40/- -/5.00/- 1.7/6.0/6.5

-/3.20/- -/4.00/- -/5.80/- 1.7/7.0/8.0

-/0.69/- -/1.09/- -/1.65/- 0.44/2.13/2.49

-/0.91/- -/1.18/- -/1.92/- 0.40/2.32/3.18

3.48 / 3.52 3.12 / 3.39 3.03 / 3.02 2.82 / 3.02

345 545 825 1,065

C/D

200x700x620 200x900x620 200x1,100x620

21.0 27.0 30.0

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

30 40

53.0 55.0 56.0

53.0 55.0 56.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

- 6.35 / 12.7

RXS25K RXS35J RXS50J RXS60F

550x765x285 550x765x285 735x825x300 735x825x300

34 34 48

33.5/- 36.0/30.1 50.9/48.9 50.9/45.0

28.3/- 28.3/25.6 45.0/43.1 46.3/46.3

-/61 -/63

46/43 48/44 49/46

47/44 48/45 49/46

-10~46 -10~46

-15~18 -15~18

6.35 6.35

9.52 9.52 12.7

15 15 20

- -

1~ / 50 / 220-240 1~ / 50 / 220-240

73

RXS25F

FDXS-E/C / RXS-K/J/F

FDXS25,35E ARC433A8

GC_pre2_lowres.pdf 73 30/11/2011 12:31:01

Page 76: DAIKIN General Catalogue 2012

74

Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling of well-being to your living space all year round. Its unobtrusive yet stylish design with a front panel that radiates additional heat, its low noise level and reduced air fl ow turn your room into a haven.

COMFORT IS KEY

The best of two

worlds united

Pure comfort and

design

radiant heat

GC_pre2_lowres.pdf 74 30/11/2011 12:31:01

Page 77: DAIKIN General Catalogue 2012

75

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

HeatingHigh/Nom./Low/ Silent operation/Radiant heat dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: full range A class energy labels › The aluminium part of the front panel of the Nexura indoor

unit has the capability of warming up, just like a traditional radiator, to add even more comfort on cold days

› The indoor unit distributes air at the sound of a whisper. The noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average.

› Comfortable vertical auto swing ensures draughtfree operation and prevents ceiling soiling

› Ideal for installation beneath a window › Can be installed against a wall or recessed › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Night set mode saves energy by preventing overcooling

or overheating during night time › Indoor/outdoor unit silent operation: “silent” buttons on the remote control

lower the operating sound of the indoor and/or outdoor unit by 3dBA each › Weekly timer can be set to start heating or cooling

anytime on a daily or weekly basis › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode. › Titanium apatite photocatalytic air purification filter removes airborne

microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit with radiant heat panel

*prEN14825 (inquiry version 2010)

75

FVXG25K FVXG35K FVXG50K

1.3/2.5 /3.0 1.4/3.5 /3.8 1.7/5.0 /5.6

1.3/3.4 /4.5 1.4/4.5 /5.0 1.7/5.8 /8.1

0.300/0.550/0.790 0.310/0.950/1.150 0.450/1.520/2.000

0.290/0.780/1.270 0.290/1.210/1.460 0.500/1.580/2.660

4.55 / 4.36 3.68 / 3.72 3.29 / 3.67

275 475 760

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5 10.6/8.9/7.3/6.0

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0 12.2/10.0/7.8/6.8

54 55 56

55 56 58

38/32/26/23 39/33/27/24 44/40/36/32

39/32/26/22/19 40/33/27/23/19 46/40/34/30/20

6.35 / 9.5 / 18 6.35 / 12.7 / 18

1~ / 50 / 220-240

RXG25K RXG35K RXG50K

550x765x285 735x825x300

34 48

33.5/30.1 36.0/30.1 50.9/48.9

28.3/25.6 45/43.1

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-15~20

15 20

-

1~ / 50 / 220-240

75

FVXG25,35,50K RXG25,35K ARC466A2

FVXG-K / RXG-K

GC_pre2_lowres.pdf 75 30/11/2011 12:31:01

Page 78: DAIKIN General Catalogue 2012

76

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

SEER* To be confirmed To be confirmed

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid/Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: full range A class energy labels › Ideal for installation beneath a window › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Can be installed against a wall or recessed › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › Titanium apatite photocatalytic air purification filter removes

airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Night set mode saves energy by preventing overcooling or overheating during night time

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.

› Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis

› Whisper quiet operation: down to 23dBA sound pressure level › Indoor/outdoor unit silent operation: “silent” button on the remote

control lowers the operation sound of the indoor/outdoor unit by 3dBA › Online controller (optional): control your indoor unit from any

location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit

*prEN14825 (inquiry version 2010)*Note: grey cells contain preliminary data

76

*FVXS25F FVXS35F FVXS50F

1.3/2.5/3.0 1.4/3.5/3.8 1.4/5.0/5.6

1.3/3.4/4.5 1.4/4.5/5.0 1.4/5.8/8.1

0.300/0.570/0.920 0.300/1.020/1.250 0.500/1.550/2.000

0.290/0.790/1.390 0.310/1.220/1.880 0.500/1.600/2.600

4.39 / 4.30 3.43 / 3.69 3.23 / 3.63

285 510 775

600x700x210

14

8.2/6.5/4.8/4.1 8.5/6.7/4.9/4.5 10.7/9.2/7.8/6.6

8.8/6.9/5.0/4.4 9.4/7.3/5.2/4.7 11.8/10.1/8.5/7.1

54 55 56

54 55 57

38/32/26/23 39/33/27/24 44/40/36/32

38/32/26/23 39/33/27/24 45/40/36/32

6.35 / 9.5 / 20.0 6.35 / 12.7 / 20.0

RXS25K RXS35J RXS50J

550x765x285 550x828x285 735x825x300

34 34 48

33.5/- 36.0/30.1 50.9/48.9

28.3/- 28.3/25.6 45.0/43.1

-/61 -/63

46/43 48/44

47/44 48/45

-10~46 -10~46

-15~18 -15~18

R-410A

6.35/9.52 6.35 / 9.52 6.35 / 12.7

15 15 20

- -

1~ / 50 / 220-240 1~ / 50 / 220-240

76

FVXS25,35,50F RXS25K ARC452A1

FVXS-F / RXS-K/J

GC_pre2_lowres.pdf 76 30/11/2011 12:31:01

Page 79: DAIKIN General Catalogue 2012

77

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B B/C C/C

Casing Colour Almond white

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High. dBA

Heating High. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas/Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure

level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid/Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: up to class A energy labels › Can fit on either ceiling or lower wall; its low height

enables the unit to fit beneath a window › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › Home leave operation maintains the indoor temperature at your

specified comfort level during absence, thus saving energy › Night set mode saves energy by preventing

overcooling or overheating during night time › Photocatalytic deodorising air purification filter deodorises

the air, powerfully decomposes odours, removes house dust and pollen and helps to prevent bacterial and viral propagation to ensure a steady supply of clean air

› Whisper quiet operation: down to 28dBA sound pressure level › Indoor/outdoor unit silent operation: “silent” button on the remote

control lowers the operation sound of the indoor/outdoor unit by 3dBA › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode › Online controller (optional): control your indoor unit from any

location via smartphone, laptop, pc, tablet or touch screen

Flexi type unit

*Note: grey cells contain preliminary data

77

*FLXS25B FLXS35B FLXS50B

1.2/2.5/3.0 1.2/3.5/3.8 0.9/4.9/5.3

1.2/3.4/4.5 1.4/4.0/5.0 0.9/6.1/7.5

0.300/0.650/0.860 0.300/1.130/1.260 0.450/1.720/1.950

0.290/0.980/1.490 0.290/1.230/1.850 0.310/1.820/3.540

3.85 / 3.47 3.10 / 3.25 2.85 / 3.35

325 565 860

490x1,050x200

16 17

7.6/6.8/6.0/5.2 8.6/7.6/6.6/5.6 11.4/10.0/8.5/7.5

9.2/8.3/7.4/6.6 9.8/8.9/8.0/7.2 12.1/9.8/7.5/6.8

53 54 63

53 55 62

37/34/31/28 38/35/32/29 47/43/39/36

37/34/31/29 39/36/33/30 46/41/35/33

6.35 / 9.5 / 18.0 6.35 / 12.7 / 18.0

RXS25K RXS35J RXS50J

550x765x285 550x765x285 735x825x300

34 34 48

33.5/- 36.0/30.1 50.9/48.9

28.3/- 28.3/25.6 45.0/43.1

-/61 -/63

46/43 48/44

47/44 48/45

-10~46 -10~46

-15~18 -15~18

R-410A

6.35 / 9.52 6.35 / 9.52 6.35 / 12.7

15 15 20

- -

1~ / 50 / 220-240 1~ / 50 / 220-240

77

RXS25K

FLXS-B / RXS-K/J

ARC433A6FLXS25,35,50B

GC_pre2_lowres.pdf 77 30/11/2011 12:31:02

Page 80: DAIKIN General Catalogue 2012

78

› Optimised heating solution for your home › Extended operation range for heating down to -20°C › Energy efficient units: full range A class energy labels › Remarkable blend of iconic design and engineering excellence with

an elegant finish in brushed aluminium or matt crystal white › Energy saving during standby mode: reduces current

consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode.

› Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body

› Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.

› Indoor/outdoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor/outdoor unit by 3dBA

› Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Night set mode saves energy by preventing overcooling or overheating during night time

› The infrared remote control is user friendly and equipped with a timer function that enables you to programme the unit to start or stop at your desired time.

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

Designed for colder climates

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating

Casing Colour Matt crystal white Brushed aluminium

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections Liquid/Gas OD mm 6.35/9.5/16 or 18

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

78

FTXG25JW FTXG35JW FTXG25JA FTXG35JA

1.3/2.5/3.0 1.4/3.5/3.8 1.3/2.5/3.0 1.4/3.5/3.8

1.3/3.4/4.5 1.4/4.5/5.0 1.3/3.4/4.5 1.4/4.5/5.0

0.56 0.89 0.56 0.89

0.78 1.11 0.78 1.11

4.46/4.36 3.93/4.04 4.46/4.36 3.93/4.04

280 445 280 445

A/A A/A

295x915x155 295x915x155

11 11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6

54 58 54 58

55 58 55 58

38/32/25/22 42/34/26/23 38/32/25/22 42/34/26/23

39/34/28/25 42/36/29/26 39/34/28/25 42/36/29/26

R-410A R-410A

6.35/9.5

550x765x285 550x765x285

34 34

33.5/30.1 36.0/30.1 33.5/30.1 36.0/30.1

28.3/25.6 30.2/25.6 28.3/25.6 30.2/25.6

-/61 -/63 -/61 -/63

46/43 48/44 46/43 48/44

47/44 48/45 47/44 48/45

-10~46 -10~46

-20~20 -20~20

15 15

- -

1~ / 50 / 220-230-240 1~ / 50 / 220-230-240

78

FTXG25,35,50J RXLG25,35K ARC466A1

FTXG-J / RXLG-K

emura

RXLG25K RXLG35K RXLG25K RXLG35K

GC_pre2_lowres.pdf 78 30/11/2011 12:31:02

Page 81: DAIKIN General Catalogue 2012

79

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air fl ow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid / Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air fl ow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level diff erence IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range for heating down to -20°C › Energy effi cient units: full range A class energy labels › The aluminium part of the front panel of the Nexura indoor

unit has the capability of warming up, just like a traditional radiator, to add even more comfort on cold days

› Ideal for installation beneath a window › Can be installed against a wall or recessed › Comfortable vertical auto swing ensures draughtfree

operation and prevents ceiling soiling › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Night set mode saves energy by preventing overcooling

or overheating during night time › The indoor unit distributes air at the sound of a whisper. The

noise produced amounts to barely 22dB(A) in cooling and 19dB(A) in radiant heat mode. In comparison, the ambient sound in a quiet room amounts to 40dB(A) on average.

› Indoor/outdoor unit silent operation: “silent” buttons on the remote control lower the operating sound of the indoor and/or outdoor unit by 3dBA each

› Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off , the unit returns to the preset mode.

› Titanium apatite photocatalytic air purifi cation fi lter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit with radiant heat panel

Designed for colder climates

79

FVXG25K FVXG35K

1.3/2.5 /3.0 1.4/3.5 /3.8

1.3/3.4 /4.5 1.4/4.5 /5.0

0.55 0.95

0.78 1.21

4.55 / 4.36 3.68 / 3.72

275 476

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0

54 55

55 56

38/32/26/23 39/33/27/24

39/32/26/22 40/33/27/23

6.35 / 9.5

1~ / 50 / 220-240

RXLG25K RXLG35K

550x765x285

34

33.5/30.1 36.0/30.1

28.3/25.6 30.2/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

79

FVXG25,35K RXLG25,35K ARC466A2

FVXG-K / RXLG-K

radiant heat

GC_pre2_lowres.pdf 79 30/11/2011 12:31:02

Page 82: DAIKIN General Catalogue 2012

80

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range down to -20°C in heating › 2 area intelligent eye: air flow is sent to a zone other than where the person

is located at that moment; if two people are detected in the room, the air flow is projected away from the occupants; if no people are detected, the unit will automatically switch over to the energy-efficient setting

› Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body

› 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces

› ECONO mode decreases power consumption so that other appliances that need large power consumption can be used

› Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode

› Night set mode saves energy by preventing overcooling or overheating during night time

› Indoor unit silent operation: “silent” button on the remote control lowers the operation sound of the indoor unit by 3dBA

› Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Wall mounted unit

Designed for colder climates

80

FTXS20J FTXS25J FTXS35J

1.3/2.0 /2.8 1.3/2.5 /3.2 1.4/3.5 /4.0

1.3/2.7 /4.3 1.3/3.3 /4.7 1.4/4.0 /5.2

0.45 0.54 0.86

0.61 0.71 0.95

4.44 / 4.43 4.67 / 4.65 4.07 / 4.21

225 268 430

295x800x215

9 10

9.4/7.4/5.5/4.1 10.8/7.9/5.2/3.7 11.4/8.7/5.8/4.4

9.9/8.2/6.6/6.2 11.9/9.1/6.4/5.9 12.4/9.5/6.8/6.0

54 57 61

54 58 61

38/32/25/22 41/33/25/22 45/37/29/23

38/33/28/25 42/35/28/25 45/39/29/26

R-410A

6.35 / 9.5

1~ / 50 / 220-240

RXL20J RXL25J RXL35J

550x765x285

32 34

36.2/32.7 33.5/30.1 36.0/30.1

30.6/28.5 28.3/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

80

FTXS20,25,35J RXL20,25,35J ARC452A3

FTXS-J / RXL-J

GC_pre2_lowres.pdf 80 30/11/2011 12:31:02

Page 83: DAIKIN General Catalogue 2012

81

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER / COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B A/A

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High. dBA

Heating High. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid/Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU-OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Optimised heating solution for your home › Extended operation range down to -20°C in heating › Ideal for installation beneath a window › Can be installed against a wall or recessed › ECONO mode decreases power consumption so that other

appliances that need large power consumption can be used › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › Energy saving during standby mode: reduces current consumption by about

80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode

› Whisper quiet operation: down to 23dBA sound pressure level › Indoor/outdoor unit silent operation: “silent” button on the remote control

lowers the operation sound of the indoor/outdoor unit by 3dBA › Night set mode saves energy by preventing overcooling

or overheating during night time › Powerful mode can be selected for rapid heating or cooling; after the

powerful mode is turned off, the unit returns to the preset mode › Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis › Titanium apatite photocatalytic air purification filter removes airborne microscopic

particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air

› Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Floor standing unit

Designed for colder climates

81

FVXS25F FVXS35F

1.3/2.5 /3.0 1.4/3.5 /3.8

1.3/3.4 /4.5 1.4/4.5 /5.0

0.57 0.81

0.99 1.22

4.39 / 3.43 4.30 / 3.69

285 407

600x700x210

14

8.2/6.5/4.8/4.1 8.5/6.7/4.9/4.5

8.8/6.9/5.0/4.4 9.4/7.3/5.2/4.7

54 55

54 55

38/32/26/23 39/33/27/24

38/32/26/23 39/33/27/24

6.35 / 9.5

RXL25J RXL35J

550x765x285

34

33.5/30.1 36.0/30.1

28.3/25.6

-/61 -/63

46/43 48/44

47/44 48/45

-10~46

-20~20

15

-

1~ / 50 / 220-230-240

81

FVXS25,35F RXL25,35J ARC452A1

FVXS-F / RXL-J

GC_pre2_lowres.pdf 81 30/11/2011 12:31:02

Page 84: DAIKIN General Catalogue 2012

82

GC_pre2_lowres.pdf 82 30/11/2011 12:31:03

Page 85: DAIKIN General Catalogue 2012

MXU & MXS

INSTALLATION FLEXIBILITY

A very wide range is available, from 2-port to 5-port units,

making all applications possible. Up to 5 indoor units can be

connected to 1 multi outdoor unit. All indoor units can be

individually controlled with remote control and do not need

to be installed in the same room or even at the same time. The

outdoor units are neat and sturdy and can be mounted easily

on a roof or terrace or simply placed against an outside wall;

WIDE CHOICE

It is possible to combine different types of indoor units:

wall mounted, fl oor standing, round fl ow cassette, ceiling

suspended, fl exi type, concealed ceiling, 4-way blow cassette

Outdoor multi split units are fitted with the Daikin swing

compressor, renowned for its low noise and high energy

efficiency.

RXYSQ

INSTALLATION FLEXIBILITY

Up to 9 indoor units can be connected to 1 multi outdoor

unit. All indoor units can be individually controlled with

remote control and do not need to be installed in the

same room or even at the same time. Narrow refrigerant

piping makes handling and connecting easier, resulting in

significantly reduced installation time. The Branch Provider

(BP) unit varies the refrigerant volume to meet the cooling or

heating requirements of a room. The BP is easy to disassemble,

making repairing and recycling more simple. The REFNET

joint reduces the amount of work involved in installation and

increases the reliability of the system. A maximum total piping

length of 145m offers much more flexibility in the choice of

installation position for the indoor units and greatly simplifies

system planning.

WIDE CHOICE

It is possible to combine different types of indoor units:

wall mounted, fl oor standing, round fl ow cassette, ceiling

suspended, fl exi type, concealed ceiling.

BP Refnet

BP

BP

Multi model applications

83

5MXS90E

RXYSQ-P8V1

GC_pre2_lowres.pdf 83 30/11/2011 12:31:04

Page 86: DAIKIN General Catalogue 2012

84

Heating & CoolingCONNECTABLE INDOOR UNITS

Indoor units CTXU25G CTXU35G CTXU42G CTXU50G

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation

dBA

Heating High/Nom./Low/Silent operation

dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE OUTDOOR UNITS

Outdoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High dBA

Heating High dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Piping length Max. OU - IU m

Level difference IU - OU Max. m

IU - IU Max. m

Heat insulation Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort cooling, heating, humidification and fresh air ventilation.

Designed primarily for two room residential use, the system comprises a visually attractive wall mounted indoor unit and a robust outdoor unit that can be installed on a balcony or against a wall.

For the humidification, called “Ururu” in Japanese, moisture is absorbed from the outdoor air. Subsequently, this humidified outdoor air streams into the indoor unit and is evenly distributed throughout the indoor areas. The Ururu Multi, therefore, works without a water reservoir and serves to evenly distribute humidified air. Humid heat operation however, is only available during the heat function.

Unlike the conventional multi system, the Ururu Multi brings fresh, conditioned air into the room. Furthermore, the temperature of the incoming air is brought to the desired level without cold or heat loss. Another benefit is that the air supply fan is accommodated in the outdoor unit, which means that you will never be bothered by any fan noises.

Ururu Multi

84

295x800x215

9 10

54 58 59

55 58 60

38/32/25/22 42/34/26/23 42/38/33/30 43/39/34/31

39/34/28/25 42/36/29/26 42/38/33/30 44/39/34/31

6.35

9.52 12.7

18

1 / 50 / 220-230-240

2MXU40G 2MXU50G

675x765x285

45 49

36/33/30 37/34/34

32/32/32 34/34/34

62 63

47 48

48 50

10~46

-15~15.5

15

15

7.5

30

1~ / 50 / 220-440

84

MXU-G

GC_pre2_lowres.pdf 84 30/11/2011 12:31:04

Page 87: DAIKIN General Catalogue 2012

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM Min. Nom. Max. Min. Nom. Max.

2MXU40G

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT HEATING (kW)COP

ENERGY LABELA ROOM B ROOM Min. Nom. Max. Min. Nom. Max.

��� ���

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM Min. Nom. Max. Min. Nom. Max.

��� ���

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT HEATING (kW)COP

ENERGY LABELA ROOM B ROOM Min. Nom. Max. Min. Nom. Max.

��� ���

MXU-G Combination tables

Ururu

Temp.: 22°C Temp.: 22°C

Humidity: 20%Cold feeling

Humidity: 50%Comfortable feeling

���� ����� ����� ����� ����� ����� ���� ����� ����� ������� ����� ����� ����� ����� ����� ����� ���� ����� ���

������� ����� ����� ����� ����� ����� ����� ����� ����� ����� ���������� ����� ����� ����� ����� ���� ����� ����� ����� ����� ���

���� ����� ����� ����� ����� ���� ����� ����� ����� ����� ����� ����� ����� ����� ���� ����� ����� ����� �

������� ����� ����� ����� ����� ����� ����� ����� ���� ����� ������� ����� ����� ����� ����� ����� ����� ����� ����� �����

��� ����� ���� ����� ����� ����� ����� ����� ���� ������ ����� ���� ����� ����� ����� ������ ����� ����� ������� ����� ���� ����� ����� ����� ������ ����� ����� � ������ ����� ���� ����� ����� ����� ������ ����� ����� � ���

������� ����� ����� ����� ����� ����� ����� ������ ���� ���� ��������� ����� ����� ����� ����� ����� ����� ������ ���� ����� ��������� ����� ����� ����� ����� ����� ����� ������ ����� ���� �������� ���� ����� ����� ����� ����� ����� ������ ����� ����� ��������� ����� ����� ����� ����� ����� ����� ������ ����� ����� ��������� ����� ����� ����� ����� ����� ����� ������ ���� ����� ��������� ���� ����� ����� ����� ����� ����� ������ ���� ����� ��������� ����� ����� ����� ����� ����� ����� ������ ���� ����� ��

��� ����� ���� ����� ����� ����� ����� ����� ���� ��� ����� ���� ����� ���� ����� ����� ���� ����� ����� ����� ���� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ���� ����� ����� ����� ����� �

������� ����� ����� ����� ���� ����� ����� ����� ����� ���� ������� ����� ����� ����� ����� ���� ����� ����� ����� ����� ������� ����� ����� ����� ����� ���� ����� ����� ����� ����� ������� ����� ����� ����� ����� ���� ����� ����� ����� ����� ������� ����� ����� ����� ����� ���� ����� ����� ���� ����� ������� ����� ����� ����� ����� ���� ����� ����� ����� ����� ������� ����� ����� ����� ����� ���� ����� ����� ���� ����� ������� ����� ����� ����� ����� ���� ����� ����� ����� �����

85

2MXU40,50G

GC_pre2_lowres.pdf 85 30/11/2011 12:31:04

Page 88: DAIKIN General Catalogue 2012

86

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Brushed aluminium

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain 16 or 18

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Multi model application

› Wide range from 2 to 5 port units › Possibility to connect up to 5 indoor units › A new 3-port 40 multi outdoor unit gives an answer to lower

capacity requirements of better insulated houses. The newly developed 15-class wall mounted allows efficient distribution of the lower capacity of the multi outdoor unit.

› All indoor units can be individually controlled and do not need to be installed in the same room or even at the same time

› Outdoor units are fitted with a Daikin swing compressor renowned for its low noise and high energy efficiency

› Possibility to combine different types of indoor units: wall mounted, floor standing, concealed ceiling, ceiling suspended units, round flow or 4-way blow cassettes

Heating & Cooling

CONNECTABLE INDOOR UNITS

Wall mounted Floor standingSlim concealed

ceilingFlexi type

Round flow cassette

4-way blow cassette

Concealed ceiling

Ceiling suspended

FTXG-J FTXS-K CTXS-K FTXS-J/G FTX-JV FVXG-K FVXS-F FDXS-E/C FLXS-B FCQ-C8 FFQ-B9V FDBQ-B/FBQ-C FHQ-B

25 35 50 20 25 15 35 25 35 42 50 60 71 25 35 50 25 35 50 25 35 50 25 35 50 60 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 35 50 60

2MXS40H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

2MXS50H ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS40K ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS52E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

3MXS68G ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS68F ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

4MXS80E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

5MXS90E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

NEW

86

FTXG25JA FTXG35JA FTXG50JA

295x915x155

11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1

54 58 60

55 58 60

38/32/25/22 42/34/26/23 44/40/35/32

39/34/28/25 42/36/29/26 44/40/35/32

6.35

9.52 12.70

86

MXS-E/F/G/H/K

GC_pre2_lowres.pdf 86 30/11/2011 12:31:04

Page 89: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Matt crystal white

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High m³/min

Heating High m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

87

Multi model application

FTXG25JW FTXG35JW FTXG50JW

295x915x155

11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1

54 58 60

55 58 60

38/32/25/22 42/34/26/23 44/40/35/32

39/34/28/25 42/36/29/26 44/40/35/32

6.35

9.52 12.70

18

FTXS20K FTXS25K CTXS15K CTXS35K

289x780x215 289x780x215

8 8

8.8/6.7/4.7/3.9 9.1/7.0/5.0/3.9 7.9/6.3/4.7/3.9 9.0/7.5/6.0/4.3

9.5/7.8/6.0/4.3 10.0/8.0/6.0/4.3 9.2/7.2/5.2/3.9 10.1/8.1/6.3/4.3

56 57 53 58

56 57 54 57

40/32/24/19 41/33/25/19 37/31/25/21 42/35/28/21

40/34/27/19 41/34/27/19 38/33/28/21 41/36/30/21

R-410A R-410A

6.35 6.35

9.52 9.52

18.0 18.0

1~ / 50 / 220-240 1~ / 50 / 220-240

FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G

290x1,050x250

10 12

11.4/8.7/5.8/4.4 11.3/9.0/6.8/5.9 11.6/9.2/7.0/6.0 16.0/13.5/11.3/10.1 17.2/14.5/11.5/10.5

12.4/9.5/6.8/6.0 12.2/9.7/7.3/6.4 12.1/9.8/7.6/6.7 17.2/14.9/12.6/11.3 19.5/16.7/14.2/12.6

61 62 61 62

61 63 60 62

45/37/29/23 45/39/33/30 46/40/34/31 45/41/36/33 46/42/37/34

45/39/29/26 45/39/33/30 47/41/34/31 44/40/35/32 46/42/37/34

12.7 15.9

18.0

FTX20JV FTX25JV FTX35JV

283x770x198

7

9.1/7.4/5.9/4.7 9.2/7.6/6.0/4.8 9.3/7.7/6.1/4.9

9.4/7.8/6.3/5.5 9.7/8.0/6.3/5.5 10.1/8.4/6.7/5.7

55 56 57

55 56 57

39/33/25/22 40/33/26/22 41/34/27/23

39/34/28/25 40/34/28/25 41/35/29/26

6.35

9.52

18

8787

MXS-E/F/G/H/K

GC_pre2_lowres.pdf 87 30/11/2011 12:31:05

Page 90: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation/Radiant heat dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Fan - External static pressure Nom. Pa

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP20 (I.D. 20/O.D. 26)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Almond white

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

88

Multi model application

FVXG25K FVXG35K FVXG50K

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5 10.6/8.9/7.3/6.0

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0 12.2/10.0/7.8/6.8

54 55 56

55 56 58

38/32/26/23 39/33/27/24 44/40/36/32

39/32/26/22/19 40/33/27/23/19 46/40/34/30/20

6.35

9.50 12.70

18

1~ / 50 / 220-240

FVXS25F FVXS35F FVXS50F

600x700x210

14

8.2/6.5/4.8/4.1 8.5/6.7/4.9/4.5 10.7/9.2/7.8/6.6

8.8/6.9/5.0/4.4 9.4/7.3/5.2/4.7 11.8/10.1/8.5/7.1

54 55 56

54 55 57

38/32/26/23 39/33/27/24 44/40/36/32

38/32/26/23 39/33/27/24 45/40/36/32

6.35

9.52 12.7

20

FDXS25E FDXS35E FDXS50C FDXS60C

200x700x620 200x900x620 200x1,100x620

21.0 27.0 30.0

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

30 40

53.0 55.0 56.0

53.0 55.0 56.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

6.35

9.52 12.7

FLXS25B FLXS35B FLXS50B FLXS60B

490x1,050x200

16 17

7.6/6.8/6.0/5.2 8.6/7.6/6.6/5.6 11.4/10.0/8.5/7.5 12.0/10.7/9.3/8.3

9.2/8.3/7.4/6.6 9.8/8.9/8.0/7.2 12.1/9.8/7.5/6.8 12.8/10.6/8.4/7.5

53 54 63 64

53 55 62 63

37/34/31/28 38/35/32/29 47/43/39/36 48/45/41/39

37/34/31/29 39/36/33/30 46/41/35/33 47/42/37/34

6.35

9.52 12.7

18

8888

MXS-E/F/G/H/K

GC_pre2_lowres.pdf 88 30/11/2011 12:31:05

Page 91: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Low dBA

Heating High/Low dBA

Sound pressure

level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS45DJW1 BYBS71DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Fan - External static pressure High/Nom. Pa

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP25 (O.D. 32 / I.D. 25)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor units *FCQG35F *FCQG50F *FCQG60F

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

89

*Note: grey cells contain preliminary data

Multi model application

2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel

FDBQ25B

230x652x502

17.0

6.50/5.20

6.95/5.20

55.0/49.0

55.0/49.0

35.0/28.0

35.0/29.0

6.35

9.52

27.2

FBQ35C8 FBQ50C8 FBQ60C8

300x700x700 300x1,000x700

350

25 34

55x800x500 55x1,100x500

3.5 4.5

16/11 18/15

16/11 18/15

100/30

63 57

-

37/29

37/29

6.35

9.52 12.70

204x840x840

19

BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

-

-

-

R-410A

-

-

-

1~ / 50/60 / 220-240/220

8989

MXS-E/F/G/H/K

GC_pre2_lowres.pdf 89 30/11/2011 12:31:05

Page 92: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYFQ60BAW1

Colour White

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Low dBA

Heating High/Low dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP20 (I.D. 20/O.D. 26)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE OUTDOOR UNITS

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A R-410A

Piping

connections

Liquid OD mm

Gas OD mm

Drain OD mm

Level difference IU - OU Max. m

IU - IU Max. m

Heat insulation Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

90

*Note: grey cells contain preliminary data

Multi model application

NEW

*FFQ25B9V *FFQ35B9V *FFQ50B9V *FFQ60B9V

-

286x575x575

17.5

55x700x700

2.7

9.0/6.5 10.0/6.5 12.0/8.0 15.0/10.0

9.0/6.5 10.0/6.5 12.0/8.0 15.0/10.0

46.5 49.0 53.0 58.0

-

29.5/24.5 32.0/25.0 36.0/27.0 41.0/32.0

29.5/24.5 32.0/25.0 36.0/27.0 41.0/32.0

6.35

9.52 12.7

26

FHQ35B FHQ50B FHQ60B

195x960x680 195x1,160x680

24 25 27

13/10 17/13

13/10 16/13

53/48 54/49 55/49

53/48 54/49 55/49

37/32 38/33 39/33

37/32 38/33 39/33

6.35

9.52 12.70

2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E

550x765x285 735x826x300 735x826x300 770x900x320

38 42 49 49 58 72 73

36/33/30 37/34/34 45/-/41 45/-/45 52.7/49.4/43.5 54.5/-/46.0 57.1/54.5/46.0

32/32/32 34/34/34 45/-/41 45/-/41 46.4/44.5/16.3 46.0/-/14.7 52.5/-/14.7

-/62 -/63 59/- -/59 -/61 -/62 -/66

47 48 46 46 48 52

48 50 47 47 49 52

10~46 -10~46 -10~46

-15~15.5 -15~15.5 -15~15.5

6.35 6.35x3 6.35

9.52 9.52x3 9.52

18 18 18 25

15 15 15

7.5 7.5 7.5

30 30 50 60 70 75

1~ / 50 / 230 1~ / 50 / 230 1~ / 50 / 230

9090

MXS-E/F/G/H/K

GC_pre2_lowres.pdf 90 30/11/2011 12:31:05

Page 93: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

2MXS40H2V1B

1.5 1.50 --- 1.22 1.50 1.59 0.32 0.33 0.35 1.5 1.5 1.5 94 4.55 A 165

2.0 2.00 --- 1.50 2.00 2.40 0.33 0.44 0.57 1.5 2.0 1.5 94 4.55 A 220

2.5 2.50 --- 1.50 2.50 3.00 0.33 0.61 0.80 1.5 2.8 1.5 94 4.10 A 305

3.5 3.50 --- 1.50 3.50 4.00 0.33 1.050 1.360 1.5 4.8 1.5 95 3.33 A 525

1.5+1.5 1.50 1.50 1.75 3.00 3.57 0.35 0.66 0.83 1.6 3.1 1.6 94 4.55 A 330

1.5+2.0 1.50 2.00 1.75 3.50 3.96 0.35 0.81 0.99 1.6 3.7 1.6 94 4.32 A 405

1.5+2.5 1.50 2.50 1.75 4.00 4.22 0.35 1.020 1.120 1.6 4.7 1.6 94 3.92 A 510

1.5+3.5 1.20 2.80 1.75 4.00 4.34 0.35 0.99 1.140 1.6 4.6 1.6 94 4.04 A 495

2.0+2.0 2.00 2.00 1.75 4.00 4.20 0.31 1.040 1.120 1.4 4.8 1.4 94 3.85 A 520

2.0+2.5 1.85 2.15 1.75 4.00 4.30 0.31 1.030 1.170 1.4 4.8 1.4 94 3.88 A 515

2.0+3.5 1.75 2.25 1.75 4.00 4.50 0.31 1.000 1.230 1.4 4.6 1.4 94 4.00 A 500

2.5+2.5 2.00 2.00 1.75 4.00 4.40 0.31 1.020 1.230 1.4 4.7 1.4 94 3.92 A 510

2.5+3.5 1.80 2.20 1.75 4.00 4.60 0.31 0.99 1.310 1.4 4.6 1.4 94 4.04 A 495

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

2MXS40H2V1B

1.5 2.60 --- 1.10 2.60 3.42 0.29 0.70 1.190 1.3 3.2 5.5 94 3.71 A

2.0 3.00 --- 1.10 3.00 3.70 0.29 0.85 1.270 1.3 3.9 5.9 94 3.53 B

2.5 3.40 --- 1.10 3.40 4.10 0.29 1.060 1.520 1.3 4.9 7.0 95 3.21 C

3.5 3.80 --- 1.10 3.80 4.40 0.29 1.290 1.730 1.3 5.9 7.9 95 2.95 D

1.5+1.5 1.90 1.90 1.30 3.80 4.26 0.30 0.90 1.110 1.4 4.1 5.1 95 4.22 A

1.5+2.0 1.71 2.29 1.30 4.00 4.44 0.30 0.95 1.150 1.4 4.3 5.3 95 4.21 A

1.5+2.5 1.58 2.63 1.30 4.20 4.58 0.30 1.020 1.220 1.4 4.7 5.6 95 4.12 A

1.5+3.5 1.32 3.08 1.30 4.40 4.70 0.29 1.090 1.200 1.3 5.0 5.5 95 4.04 A

2.0+2.0 2.10 2.10 1.40 4.20 4.60 0.27 1.010 1.170 1.2 4.6 5.4 95 4.16 A

2.0+2.5 2.10 2.30 1.40 4.40 4.70 0.27 1.080 1.210 1.2 4.9 5.5 96 4.07 A

2.0+3.5 2.00 2.40 1.40 4.40 4.70 0.26 1.060 1.190 1.2 4.8 5.4 96 4.15 A

2.5+2.5 2.20 2.20 1.40 4.40 4.70 0.27 1.070 1.200 1.2 4.8 5.4 96 4.11 A

2.5+3.5 2.05 2.35 1.40 4.40 4.70 0.26 1.050 1.180 1.2 4.8 5.3 96 4.19 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB(Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB(Outdoor temperature). 2. The total ability of connected a indoor unit is up to 6.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW Class; wall mounted K series

* This page contains preliminary data

91

2MXS-H

GC_pre2_lowres.pdf 91 30/11/2011 12:31:05

Page 94: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

2MXS50H2V1B

1.5 1.50 --- 1.22 1.50 1.22 0.28 0.29 0.41 1.3 1.4 2.0 91 5.17 A 145

2.0 2.00 --- 1.30 2.00 1.30 0.30 0.39 0.58 1.4 1.9 2.8 91 5.13 A 195

2.5 2.50 --- 1.30 2.50 1.30 0.30 0.56 0.80 1.4 2.7 3.8 91 4.46 A 280

3.5 3.50 --- 1.30 3.50 1.30 0.30 0.94 1.24 1.4 4.5 5.9 91 3.72 A 470

4.2 4.20 --- 1.60 4.20 1.60 0.32 1.38 1.85 1.5 6.6 8.8 91 3.04 B 690

5.0 5.00 --- 1.60 5.00 1.60 0.32 1.94 2.07 1.5 9.3 9.9 91 2.58 E 970

1.5+1.5 1.50 1.50 1.88 3.00 1.88 0.33 0.55 0.58 1.6 2.6 2.8 91 5.45 A 275

1.5+2.0 1.50 2.00 1.88 3.50 1.88 0.32 0.67 0.75 1.5 3.2 3.6 91 5.22 A 335

1.5+2.5 1.50 2.50 1.88 4.00 1.88 0.32 0.87 0.97 1.5 4.2 4.6 91 4.60 A 435

1.5+3.5 1.50 3.50 1.88 5.00 1.88 0.32 1.35 1.35 1.5 6.5 6.5 91 3.70 A 675

1.5+4.2 1.32 3.68 1.95 5.00 1.95 0.34 1.35 1.67 1.6 6.5 8.0 91 3.70 A 675

1.5+5.0 1.15 3.85 1.95 5.00 1.95 0.34 1.35 1.81 1.6 6.5 8.6 91 3.70 A 675

2.0+2.0 2.00 2.00 1.95 4.00 1.95 0.34 0.87 1.36 1.6 4.2 6.5 91 4.60 A 435

2.0+2.5 2.00 2.50 1.95 4.50 1.95 0.34 1.07 1.45 1.6 5.1 6.9 91 4.21 A 535

2.0+3.5 1.82 3.18 1.95 5.00 1.95 0.34 1.35 1.62 1.6 6.5 7.7 91 3.70 A 675

2.0+4.2 1.61 3.39 1.95 5.00 1.95 0.34 1.34 1.73 1.6 6.4 8.3 91 3.73 A 670

2.0+5.0 1.43 3.57 1.95 5.00 1.95 0.34 1.31 1.71 1.6 6.3 8.2 91 3.82 A 655

2.5+2.5 2.50 2.50 1.95 5.00 1.95 0.34 1.38 1.61 1.6 6.6 7.7 91 3.62 A 690

2.5+3.5 2.08 2.92 1.95 5.00 1.95 0.34 1.34 1.61 1.6 6.4 7.7 91 3.73 A 670

2.5+4.2 1.87 3.13 1.95 5.00 1.95 0.34 1.33 1.72 1.6 6.4 8.2 91 3.76 A 665

2.5+5.0 1.67 3.33 1.95 5.00 1.95 0.34 1.30 1.70 1.6 6.2 8.1 91 3.85 A 650

3.5+3.5 2.50 2.50 1.98 5.00 1.98 0.34 1.29 1.55 1.6 6.2 7.4 91 3.88 A 645

3.5+4.2 2.27 2.73 1.98 5.00 1.98 0.34 1.28 1.65 1.6 6.1 7.9 91 3.91 A 640

3.5+5.0 2.06 2.94 1.98 5.00 1.98 0.34 1.27 1.62 1.6 6.1 7.7 91 3.94 A 635

4.2+4.2 2.50 2.50 1.98 5.00 1.98 0.34 1.27 1.62 1.6 6.1 7.7 91 3.94 A 635

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

2MXU50HV1B

1.5 2.60 --- 1.15 2.60 3.27 0.24 0.67 0.92 1.1 3.2 4.4 91 3.88 A

2.0 3.00 --- 1.16 3.00 3.70 0.24 0.81 1.12 1.1 3.9 5.4 91 3.70 A

2.5 3.40 --- 1.16 3.40 4.10 0.24 0.97 1.30 1.1 4.6 6.2 91 3.51 B

3.5 4.00 --- 1.16 4.00 4.60 0.24 1.24 1.52 1.1 5.9 7.3 91 3.23 C

4.2 4.70 --- 1.16 4.70 5.10 0.22 1.49 1.73 1.1 7.1 8.3 91 3.15 D

5.0 5.40 --- 1.28 5.40 5.60 0.23 1.77 2.01 1.1 8.5 9.6 91 3.05 D

1.5+1.5 1.99 1.99 1.17 3.97 4.54 0.22 0.95 1.20 1.1 4.5 5.7 91 4.18 A

1.5+2.0 1.90 2.53 1.17 4.43 4.89 0.22 1.08 1.29 1.1 5.2 6.2 91 4.10 A

1.5+2.5 1.81 3.02 1.17 4.83 5.19 0.23 1.16 1.39 1.1 5.5 6.6 91 4.16 A

1.5+3.5 1.64 3.82 1.17 5.46 5.70 0.23 1.39 1.60 1.1 6.6 7.6 91 3.93 A

1.5+4.2 1.50 4.20 1.17 5.70 5.96 0.24 1.41 1.53 1.1 6.7 7.3 91 4.04 A

1.5+5.0 1.32 4.38 1.17 5.70 6.16 0.24 1.44 1.62 1.1 6.9 7.7 91 3.96 A

2.0+2.0 2.65 2.65 1.18 5.30 5.70 0.23 1.34 1.51 1.1 6.4 7.2 91 3.96 A

2.0+2.5 2.44 3.06 1.18 5.50 5.80 0.23 1.37 1.52 1.1 6.5 7.3 91 4.01 A

2.0+3.5 2.04 3.56 1.24 5.60 5.90 0.24 1.39 1.55 1.1 6.6 7.4 91 4.03 A

2.0+4.2 1.84 3.86 1.25 5.70 6.00 0.25 1.35 1.50 1.2 6.5 7.2 91 4.22 A

2.0+5.0 1.63 4.07 1.29 5.70 6.20 0.25 1.38 1.55 1.2 6.6 7.4 91 4.13 A

2.5+2.5 2.80 2.80 1.18 5.60 5.80 0.23 1.42 1.52 1.1 6.8 7.3 91 3.94 A

2.5+3.5 2.38 3.32 1.24 5.70 6.00 0.25 1.41 1.58 1.2 6.7 7.5 91 4.04 A

2.5+4.2 2.13 3.57 1.25 5.70 6.10 0.25 1.36 1.51 1.2 6.5 7.2 91 4.19 A

2.5+5.0 1.90 3.80 1.35 5.70 6.30 0.26 1.35 1.56 1.2 6.5 7.5 91 4.22 A

3.5+3.5 2.85 2.85 1.30 5.70 6.10 0.25 1.46 1.63 1.2 7.0 7.8 91 3.90 A

3.5+4.2 2.59 3.11 1.31 5.70 6.20 0.26 1.38 1.51 1.2 6.6 7.2 91 4.13 A

3.5+5.0 2.35 3.35 1.35 5.70 6.40 0.27 1.38 1.56 1.3 6.6 7.5 91 4.13 A

4.2+4.2 2.85 2.85 1.32 5.70 6.30 0.23 1.31 1.50 1.1 6.3 7.2 91 4.35 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 8.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series

* This page contains preliminary data

92

2MXS-H

GC_pre2_lowres.pdf 92 30/11/2011 12:31:05

Page 95: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS40K2V1B

1.5 1.50 --- --- --- 1.38 1.50 2.10 0.34 0.34 0.48 1.5 1.5 2.2 96 4.41 A 170

2.0 2.00 --- --- --- 1.41 2.00 2.84 0.34 0.46 0.74 1.5 2.1 3.4 96 4.35 A 230

2.5 2.50 --- --- --- 1.41 2.50 3.12 0.34 0.62 0.88 1.5 2.8 3.9 97 4.03 A 310

3.5 3.50 --- --- --- 1.41 3.50 4.18 0.34 0.97 1.29 1.5 4.3 5.7 98 3.61 A 485

1.5+1.5 1.50 1.50 --- --- 1.78 3.00 4.20 0.35 0.63 1.12 1.6 2.8 5.0 98 4.76 A 315

1.5+2.0 1.50 2.00 --- --- 1.78 3.50 4.20 0.35 0.80 1.12 1.5 3.5 4.9 99 4.38 A 400

1.5+2.5 1.50 2.50 --- --- 1.78 4.00 4.20 0.35 0.98 1.12 1.5 4.3 4.9 99 4.08 A 490

1.5+3.5 1.20 2.80 --- --- 1.78 4.00 4.21 0.35 0.98 1.12 1.5 4.3 4.9 99 4.08 A 490

2.0+2.0 2.00 2.00 --- --- 1.88 4.00 4.54 0.35 0.95 1.12 1.5 4.2 4.9 99 4.21 A 475

2.0+2.5 1.78 2.22 --- --- 1.88 4.00 4.54 0.35 0.95 1.12 1.5 4.2 4.9 99 4.21 A 475

2.0+3.5 1.45 2.55 --- --- 1.88 4.00 4.55 0.35 0.95 1.09 1.5 4.2 4.8 99 4.21 A 475

2.5+2.5 2.00 2.00 --- --- 1.88 4.00 4.54 0.35 0.95 1.12 1.5 4.2 4.9 99 4.21 A 475

2.5+3.5 1.67 2.33 --- --- 1.88 4.00 4.54 0.35 0.95 1.12 1.5 4.2 4.9 99 4.21 A 475

3.5+3.5 2.00 2.00 --- --- 1.88 4.00 4.58 0.35 0.95 1.12 1.5 4.2 4.9 99 4.21 A 475

1.5+1.5+1.5 1.33 1.33 1.33 --- 1.80 4.00 4.60 0.35 0.83 0.98 1.5 3.6 4.3 99 4.82 A 415

1.5+1.5+2.0 1.20 1.20 1.60 --- 1.80 4.00 4.60 0.35 0.84 0.98 1.5 3.7 4.3 99 4.76 A 420

1.5+1.5+2.5 1.09 1.09 1.82 --- 1.80 4.00 4.60 0.35 0.84 0.98 1.5 3.7 4.3 99 4.76 A 420

1.5+1.5+3.5 0.92 0.92 2.15 --- 1.80 4.00 4.60 0.37 0.84 0.98 1.6 3.7 4.3 99 4.76 A 420

1.5+2.0+2.0 1.09 1.45 1.45 --- 1.80 4.00 4.60 0.35 0.84 0.98 1.5 3.7 4.3 99 4.76 A 420

1.5+2.0+2.5 1.00 1.33 1.67 --- 1.80 4.00 4.60 0.35 0.84 0.98 1.5 3.7 4.3 99 4.76 A 420

1.5+2.0+3.5 0.86 1.14 2.00 --- 1.80 4.00 4.60 0.37 0.84 0.98 1.6 3.7 4.3 99 4.76 A 420

1.5+2.5+2.5 0.92 1.54 1.54 --- 1.80 4.00 4.60 0.37 0.84 0.98 1.6 3.7 4.3 99 4.76 A 420

2.0+2.0+2.0 1.33 1.33 1.33 --- 1.86 4.00 4.60 0.35 0.81 0.98 1.5 3.6 4.3 99 4.94 A 405

2.0+2.0+2.5 1.23 1.23 1.54 --- 1.86 4.00 4.60 0.35 0.81 0.98 1.5 3.6 4.3 99 4.94 A 405

2.0+2.5+2.5 1.14 1.43 1.43 --- 1.95 4.00 4.60 0.37 0.81 0.98 1.6 3.6 4.3 99 4.94 A 405

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS40K2V1B

1.5 2.27 --- --- --- 1.19 2.27 2.64 0.30 0.58 0.79 1.4 2.6 3.6 96 3.91 A

2.0 2.72 --- --- --- 1.21 2.72 3.75 0.30 0.72 1.20 1.4 3.3 5.4 96 3.78 A

2.5 3.40 --- --- --- 1.21 3.40 4.00 0.30 0.99 1.26 1.3 4.4 5.6 97 3.43 B

3.5 4.20 --- --- --- 1.21 4.20 4.82 0.30 1.39 1.68 1.3 6.2 7.5 98 3.02 D

1.5+1.5 2.30 2.30 --- --- 1.22 4.60 5.00 0.30 1.11 1.29 1.4 4.9 5.7 99 4.14 A

1.5+2.0 1.97 2.63 --- --- 1.22 4.60 5.00 0.31 1.11 1.29 1.4 4.9 5.7 99 4.14 A

1.5+2.5 1.73 2.88 --- --- 1.22 4.60 5.00 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

1.5+3.5 1.38 3.22 --- --- 1.25 4.60 5.02 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

2.0+2.0 2.30 2.30 --- --- 1.28 4.60 5.00 0.31 1.11 1.29 1.4 4.9 5.7 99 4.14 A

2.0+2.5 2.04 2.56 --- --- 1.28 4.60 5.00 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

2.0+3.5 1.67 2.93 --- --- 1.34 4.60 5.02 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

2.5+2.5 2.30 2.30 --- --- 1.28 4.60 5.00 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

2.5+3.5 1.92 2.68 --- --- 1.34 4.60 5.02 0.31 1.10 1.29 1.4 4.8 5.7 99 4.18 A

3.5+3.5 2.30 2.30 --- --- 1.40 4.60 5.04 0.31 1.10 1.28 1.4 4.8 5.6 99 4.18 A

1.5+1.5+1.5 1.53 1.53 1.53 --- 1.32 4.60 5.00 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

1.5+1.5+2.0 1.38 1.38 1.84 --- 1.32 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

1.5+1.5+2.5 1.25 1.25 2.09 --- 1.32 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

1.5+1.5+3.5 1.06 1.06 2.48 --- 1.32 4.60 5.09 0.32 0.91 1.01 1.4 4.0 4.4 99 5.05 A

1.5+2.0+2.0 1.25 1.67 1.67 --- 1.32 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

1.5+2.0+2.5 1.15 1.53 1.92 --- 1.33 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

1.5+2.0+3.5 0.99 1.31 2.30 --- 1.33 4.60 5.09 0.32 0.91 1.01 1.4 4.0 4.4 99 5.05 A

1.5+2.5+2.5 1.06 1.77 1.77 --- 1.33 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

2.0+2.0+2.0 1.53 1.53 1.53 --- 1.34 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

2.0+2.0+2.5 1.42 1.42 1.77 --- 1.34 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

2.0+2.5+2.5 1.31 1.64 1.64 --- 1.45 4.60 5.07 0.32 0.91 1.02 1.4 4.0 4.5 99 5.05 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 7.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5. kW class; wall mounted K series

* This page contains preliminary data

93

3MXS-K

GC_pre2_lowres.pdf 93 30/11/2011 12:31:06

Page 96: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS52E3V1B

1.5 1.50 --- --- --- 1.38 1.50 2.10 0.35 0.39 0.46 1.6 1.8 2.1 96 3.85 A 195

2.0 2.00 --- --- --- 1.41 2.00 2.84 0.35 0.46 0.74 1.6 2.1 3.4 96 4.35 A 230

2.5 2.50 --- --- --- 1.41 2.50 3.12 0.35 0.62 0.88 1.6 2.8 3.9 97 4.03 A 310

3.5 3.50 --- --- --- 1.41 3.50 4.18 0.35 0.97 1.29 1.6 4.3 5.7 98 3.61 A 485

4.2 4.20 --- --- --- 1.76 4.20 4.70 0.35 1.24 1.64 1.6 5.5 7.3 98 3.39 A 620

5.0 --- --- 5.00 --- 1.79 5.00 5.40 0.35 1.75 2.03 1.5 7.7 8.9 99 2.86 C 875

1.5+1.5 1.50 1.50 --- --- 1.88 3.00 4.72 0.35 0.61 1.30 1.5 2.7 5.7 99 4.92 A 305

1.5+2.0 1.50 2.00 --- --- 1.88 3.50 4.72 0.35 0.77 1.30 1.5 3.4 5.7 99 4.55 A 385

1.5+2.5 1.50 2.50 --- --- 1.88 4.00 5.68 0.35 0.95 1.91 1.5 4.2 8.4 99 4.21 A 475

1.5+3.5 1.50 3.50 --- --- 1.88 5.00 5.99 0.35 1.45 2.17 1.5 6.4 9.5 99 3.45 A 725

1.5+4.2 1.37 3.83 --- --- 1.88 5.20 6.08 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

1.5+5.0 1.20 --- 4.00 --- 1.88 5.20 6.29 0.35 1.46 2.27 1.5 6.4 10.0 99 3.56 A 730

2.0+2.0 2.00 2.00 --- --- 1.88 4.00 5.96 0.35 0.95 1.91 1.5 4.2 8.4 99 4.21 A 475

2.0+2.5 2.00 2.50 --- --- 1.88 4.50 6.23 0.35 1.18 2.14 1.5 5.2 9.4 99 3.81 A 590

2.0+3.5 1.89 3.31 --- --- 1.88 5.20 6.24 0.35 1.55 2.07 1.5 6.8 9.1 99 3.35 A 775

2.0+4.2 1.68 3.52 --- --- 1.88 5.20 6.25 0.35 1.55 2.07 1.5 6.8 9.1 99 3.35 A 775

2.0+5.0 1.49 --- 3.71 --- 1.88 5.20 6.47 0.35 1.42 2.15 1.5 6.2 9.4 99 3.66 A 710

2.5+2.5 2.50 2.50 --- --- 1.88 5.00 6.23 0.35 1.45 2.14 1.5 6.4 9.4 99 3.45 A 725

2.5+3.5 2.17 3.03 --- --- 1.88 5.20 6.35 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

2.5+4.2 1.94 3.26 --- --- 1.88 5.20 6.36 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

2.5+5.0 1.73 --- 3.47 --- 1.88 5.20 6.47 0.35 1.42 2.07 1.5 6.2 9.1 99 3.66 A 710

3.5+3.5 2.60 2.60 --- --- 1.88 5.20 6.40 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

3.5+4.2 2.36 2.84 --- --- 1.88 5.20 6.41 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

3.5+5.0 2.14 --- 3.06 --- 1.88 5.21 6.49 0.35 1.42 2.09 1.5 6.2 9.2 99 3.67 A 710

4.2+4.2 2.60 2.60 --- --- 1.88 5.20 6.42 0.35 1.55 2.25 1.5 6.8 9.9 99 3.35 A 775

1.5+1.5+1.5 1.50 1.50 1.50 --- 1.86 4.50 6.71 0.35 0.97 2.16 1.5 4.3 9.5 99 4.64 A 485

1.5+1.5+2.0 1.50 1.50 2.00 --- 1.86 5.00 6.71 0.35 1.18 2.16 1.5 5.2 9.5 99 4.24 A 590

1.5+1.5+2.5 1.42 1.42 2.36 --- 1.86 5.20 6.71 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+1.5+3.5 1.20 1.20 2.80 --- 1.95 5.20 6.72 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+1.5+4.2 1.08 1.08 3.03 --- 1.95 5.19 6.73 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+1.5+5.0 0.98 0.98 3.25 --- 2.11 5.21 6.90 0.35 1.21 2.17 1.5 5.3 9.5 99 4.31 A 605

1.5+2.0+2.0 1.42 1.89 1.89 --- 1.86 5.20 6.71 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.0+2.5 1.30 1.73 2.17 --- 1.86 5.20 6.71 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.0+3.5 1.11 1.49 2.60 --- 1.95 5.20 6.72 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.0+4.2 1.01 1.35 2.84 --- 1.95 5.20 6.73 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.0+5.0 0.92 1.22 3.06 --- 2.11 5.20 6.90 0.35 1.21 2.17 1.5 5.3 9.5 99 4.30 A 605

1.5+2.5+2.5 1.20 2.00 2.00 --- 1.86 5.20 6.71 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.5+3.5 1.04 1.73 2.43 --- 1.95 5.20 6.72 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.5+4.2 0.95 1.59 2.66 --- 1.95 5.20 6.73 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

1.5+2.5+5.0 0.87 1.44 2.89 --- 2.11 5.20 6.90 0.35 1.21 2.17 1.5 5.3 9.5 99 4.30 A 605

1.5+3.5+3.5 0.92 2.14 2.14 --- 1.86 5.20 6.73 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

2.0+2.0+2.0 1.73 1.73 1.73 --- 1.86 5.19 7.04 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

2.0+2.0+2.5 1.60 1.60 1.99 --- 1.86 5.19 7.04 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

2.0+2.0+3.5 1.38 1.38 2.43 --- 1.95 5.19 7.06 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.0+2.0+4.2 1.27 1.27 2.66 --- 1.95 5.20 7.07 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.0+2.0+5.0 1.16 1.16 2.88 --- 2.11 5.20 7.30 0.38 1.22 2.26 1.7 5.4 9.9 99 4.26 A 610

2.0+2.5+2.5 1.49 1.85 1.85 --- 1.86 5.19 7.04 0.35 1.24 2.16 1.5 5.4 9.5 99 4.19 A 620

2.0+2.5+3.5 1.30 1.63 2.27 --- 1.95 5.20 7.06 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.0+2.5+4.2 1.20 1.49 2.51 --- 1.95 5.20 7.07 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.0+3.5+3.5 1.16 2.02 2.02 --- 1.95 5.20 7.07 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.5+2.5+2.5 1.73 1.73 1.73 --- 1.95 5.19 7.04 0.37 1.24 2.16 1.6 5.4 9.5 99 4.19 A 620

2.5+2.5+3.5 1.53 1.53 2.14 --- 1.95 5.20 7.06 0.37 1.23 2.16 1.6 5.4 9.5 99 4.23 A 615

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor Temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°DB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 9.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series

* This page contains preliminary data

94

3MXS-E

GC_pre2_lowres.pdf 94 30/11/2011 12:31:06

Page 97: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS52E3V1B

1.5 2.27 --- --- --- 1.21 2.27 2.77 0.30 0.58 0.75 1.4 2.6 3.4 96 3.91 A

2.0 2.72 --- --- --- 1.21 2.72 3.75 0.30 0.72 1.20 1.4 3.3 5.4 96 3.78 A

2.5 3.40 --- --- --- 1.21 3.40 4.00 0.30 0.99 1.26 1.3 4.4 5.6 97 3.43 B

3.5 4.20 --- --- --- 1.21 4.20 4.82 0.30 1.39 1.68 1.3 6.2 7.5 98 3.02 D

4.2 4.70 --- --- --- 1.21 4.70 5.87 0.30 1.70 2.40 1.3 7.5 10.6 98 2.76 E

5.0 --- --- 5.80 --- 1.33 5.80 6.79 0.30 2.16 2.59 1.3 9.5 11.4 99 2.69 E

1.5+1.5 1.81 1.81 --- --- 1.28 3.62 5.81 0.31 0.81 1.64 1.4 3.6 7.2 99 4.47 A

1.5+2.0 1.74 2.33 --- --- 1.28 4.07 5.81 0.31 0.94 1.64 1.4 4.1 7.2 99 4.33 A

1.5+2.5 1.70 2.83 --- --- 1.28 4.53 6.93 0.31 1.07 2.28 1.4 4.7 10.0 99 4.23 A

1.5+3.5 1.63 3.79 --- --- 1.28 5.42 6.96 0.31 1.37 2.28 1.4 6.0 10.0 99 3.96 A

1.5+4.2 1.59 4.46 --- --- 1.28 6.05 6.98 0.31 1.64 2.27 1.4 7.2 10.0 99 3.69 A

1.5+5.0 1.56 --- 5.21 --- 1.27 6.77 7.20 0.31 1.83 2.32 1.4 8.0 10.2 99 3.70 A

2.0+2.0 3.05 3.05 --- --- 1.28 6.10 7.00 0.31 1.70 2.28 1.4 7.5 10.0 99 3.59 B

2.0+2.5 2.78 3.47 --- --- 1.28 6.25 7.00 0.31 1.75 2.28 1.4 7.7 10.0 99 3.57 B

2.0+3.5 2.38 4.17 --- --- 1.34 6.55 7.04 0.31 1.86 2.28 1.4 8.2 10.0 99 3.52 B

2.0+4.2 2.16 4.54 --- --- 1.34 6.70 7.05 0.31 1.93 2.27 1.4 8.5 10.0 99 3.47 B

2.0+5.0 1.94 --- 4.86 --- 1.39 6.80 7.20 0.31 1.87 2.32 1.4 8.2 10.2 99 3.64 A

2.5+2.5 3.25 3.25 --- --- 1.28 6.50 7.00 0.31 1.86 2.31 1.4 8.2 10.1 99 3.49 B

2.5+3.5 2.79 3.91 --- --- 1.34 6.70 7.19 0.31 1.93 2.36 1.4 8.5 10.4 99 3.47 B

2.5+4.2 2.54 4.26 --- --- 1.34 6.80 7.21 0.31 1.93 2.35 1.4 8.5 10.3 99 3.52 B

2.5+5.0 2.27 --- 4.53 --- 1.45 6.80 7.35 0.31 1.87 2.32 1.4 8.2 10.2 99 3.64 A

3.5+3.5 3.40 3.40 --- --- 1.40 6.80 7.22 0.31 1.97 2.35 1.4 8.7 10.3 99 3.45 B

3.5+4.2 3.09 3.71 --- --- 1.40 6.80 7.24 0.31 1.97 2.35 1.4 8.7 10.3 99 3.45 B

3.5+5.0 2.80 --- 4.00 --- 1.45 6.80 7.50 0.31 1.83 2.31 1.4 8.0 10.1 99 3.72 A

4.2+4.2 3.40 3.40 --- --- 1.40 6.80 7.26 0.31 1.96 2.34 1.4 8.6 10.3 99 3.47 B

1.5+1.5+1.5 1.66 1.66 1.66 --- 1.34 4.98 8.02 0.32 1.02 2.14 1.4 4.5 9.4 99 4.88 A

1.5+1.5+2.0 1.63 1.63 2.17 --- 1.34 5.43 8.02 0.32 1.12 2.14 1.4 4.9 9.4 99 4.85 A

1.5+1.5+2.5 1.60 1.60 2.67 --- 1.34 5.87 8.02 0.32 1.26 2.14 1.4 5.5 9.4 99 4.66 A

1.5+1.5+3.5 1.56 1.56 3.65 --- 1.45 6.77 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.34 A

1.5+1.5+4.2 1.42 1.42 3.96 --- 1.45 6.80 8.06 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

1.5+1.5+5.0 1.28 1.28 4.24 --- 1.67 6.80 8.27 0.32 1.64 2.11 1.4 7.2 9.3 99 4.15 A

1.5+2.0+2.0 1.60 2.13 2.13 --- 1.34 5.86 8.02 0.32 1.26 2.14 1.4 5.5 9.4 99 4.65 A

1.5+2.0+2.5 1.58 2.11 2.63 --- 1.34 6.32 8.02 0.32 1.41 2.14 1.4 6.2 9.4 99 4.48 A

1.5+2.0+3.5 1.46 1.94 3.40 --- 1.45 6.80 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

1.5+2.0+4.2 1.32 1.77 3.71 --- 1.45 6.80 8.06 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

1.5+2.0+5.0 1.20 1.60 4.00 --- 1.67 6.80 8.27 0.32 1.64 2.11 1.4 7.2 9.3 99 4.15 A

1.5+2.5+2.5 1.56 2.60 2.60 --- 1.34 6.76 8.02 0.32 1.57 2.14 1.4 6.9 9.4 99 4.31 A

1.5+2.5+3.5 1.36 2.27 3.17 --- 1.45 6.80 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

1.5+2.5+4.2 1.24 2.07 3.48 --- 1.45 6.79 8.06 0.32 1.56 2.14 1.4 6.9 9.4 99 4.35 A

1.5+2.5+5.0 1.13 1.89 3.78 --- 1.67 6.80 8.27 0.32 1.64 2.11 1.4 7.2 9.3 99 4.15 A

1.5+3.5+3.5 1.20 2.80 2.80 --- 1.34 6.80 8.08 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

2.0+2.0+2.0 2.26 2.26 2.26 --- 1.34 6.78 8.02 0.32 1.57 2.14 1.4 6.9 9.4 99 4.32 A

2.0+2.0+2.5 2.09 2.09 2.60 --- 1.34 6.78 8.02 0.32 1.57 2.14 1.4 6.9 9.4 99 4.32 A

2.0+2.0+3.5 1.80 1.80 3.18 --- 1.45 6.78 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.35 A

2.0+2.0+4.2 1.66 1.66 3.48 --- 1.45 6.80 8.06 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

2.0+2.0+5.0 1.51 1.51 3.78 --- 1.67 6.80 8.27 0.32 1.64 2.11 1.4 7.2 9.3 99 4.15 A

2.0+2.5+2.5 1.94 2.42 2.42 --- 1.34 6.78 8.02 0.32 1.57 2.14 1.4 6.9 9.4 99 4.32 A

2.0+2.5+3.5 1.70 2.13 2.97 --- 1.57 6.80 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

2.0+2.5+4.2 1.56 1.95 3.28 --- 1.56 6.80 8.06 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

2.0+3.5+3.5 1.52 2.64 2.64 --- 1.56 6.80 8.08 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

2.5+2.5+2.5 2.26 2.26 2.26 --- 1.45 6.78 8.02 0.32 1.57 2.14 1.4 6.9 9.4 99 4.32 A

2.5+2.5+3.5 2.00 2.00 2.80 --- 1.57 6.80 8.05 0.32 1.56 2.14 1.4 6.9 9.4 99 4.36 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor Temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°DB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 9.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series

* This page contains preliminary data

95

3MXS-E

GC_pre2_lowres.pdf 95 30/11/2011 12:31:06

Page 98: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS68G2V1B

1.5 1.50 --- --- --- 1.43 1.50 2.46 0.42 0.46 0.55 1.9 2.1 2.5 96 3.26 A 230

2.0 2.00 --- --- --- 1.57 2.00 2.63 0.42 0.46 0.62 1.9 2.1 2.8 96 4.35 A 230

2.5 2.50 --- --- --- 1.57 2.50 3.37 0.44 0.58 0.85 2.0 2.6 3.8 96 4.31 A 290

3.5 3.50 --- --- --- 1.57 3.50 4.76 0.45 0.89 1.47 2.0 3.9 6.5 98 3.93 A 445

4.2 4.20 --- --- --- 1.95 4.20 5.02 0.47 1.21 1.62 2.1 5.4 7.2 98 3.47 A 605

5.0 5.00 --- --- --- 1.96 5.00 5.91 0.45 1.71 2.20 2.0 7.5 9.7 99 2.92 C 855

6.0 6.00 --- --- --- 1.96 6.00 6.38 0.44 2.05 2.32 1.9 9.0 10.2 99 2.93 C 1025

1.5+1.5 1.50 1.50 --- --- 1.97 3.00 4.70 0.43 0.65 1.29 1.9 2.9 5.7 99 4.62 A 325

1.5+2.0 1.50 2.00 --- --- 1.97 3.50 4.86 0.43 0.80 1.37 1.9 3.5 6.0 99 4.38 A 400

1.5+2.5 1.50 2.50 --- --- 1.97 4.00 6.04 0.43 0.99 2.04 1.9 4.3 9.0 99 4.04 A 495

1.5+3.5 1.50 3.50 --- --- 1.97 5.00 6.25 0.42 1.39 2.20 1.8 6.1 9.7 99 3.60 A 695

1.5+4.2 1.50 4.20 --- --- 1.97 5.70 6.26 0.42 1.79 2.20 1.8 7.9 9.7 99 3.18 B 895

1.5+5.0 1.50 5.00 --- --- 1.97 6.50 7.06 0.41 2.22 2.60 1.8 9.7 11.4 99 2.93 C 1110

1.5+6.0 1.36 5.44 --- --- 1.98 6.80 7.38 0.40 2.26 2.60 1.8 9.9 11.4 99 3.01 B 1130

2.0+2.0 2.00 2.00 --- --- 1.97 4.00 5.02 0.43 1.00 1.45 1.9 4.4 6.4 99 4.00 A 500

2.0+2.5 2.00 2.50 --- --- 1.97 4.50 5.33 0.43 1.20 1.61 1.9 5.3 7.1 99 3.75 A 600

2.0+3.5 2.00 3.50 --- --- 1.97 5.50 6.18 0.42 1.66 2.15 1.8 7.3 9.4 99 3.31 A 830

2.0+4.2 2.00 4.20 --- --- 1.97 6.20 6.38 0.42 2.09 2.30 1.8 9.2 10.1 99 2.97 C 1045

2.0+5.0 1.94 4.86 --- --- 1.97 6.80 7.12 0.41 2.41 2.65 1.8 10.6 11.6 99 2.82 C 1205

2.0+6.0 1.70 5.10 --- --- 1.98 6.80 7.56 0.40 2.21 2.75 1.8 9.7 12.1 99 3.08 B 1105

2.5+2.5 2.50 2.50 --- --- 1.97 5.00 5.98 0.45 1.46 2.00 2.0 6.4 8.8 99 3.42 A 730

2.5+3.5 2.50 3.50 --- --- 1.97 6.00 6.44 0.43 2.06 2.37 1.9 9.0 10.4 99 2.91 C 1030

2.5+4.2 2.50 4.20 --- --- 1.97 6.70 6.81 0.43 2.54 2.67 1.9 11.2 11.7 99 2.64 D 1270

2.5+5.0 2.27 4.53 --- --- 1.97 6.80 7.23 0.40 2.41 2.75 1.8 10.6 12.1 99 2.82 C 1205

2.5+6.0 2.00 4.80 --- --- 1.98 6.80 7.56 0.38 2.21 2.75 1.7 9.7 12.1 99 3.08 B 1105

3.5+3.5 3.40 3.40 --- --- 1.97 6.80 6.99 0.41 2.51 2.66 1.8 11.0 11.7 99 2.71 D 1255

3.5+4.2 3.09 3.71 --- --- 1.97 6.80 7.10 0.41 2.51 2.76 1.8 11.0 12.1 99 2.71 D 1255

3.5+5.0 2.80 4.00 --- --- 1.97 6.80 7.61 0.38 2.41 3.12 1.7 10.6 13.7 99 2.82 C 1205

3.5+6.0 2.51 4.29 --- --- 2.28 6.80 7.91 0.43 2.21 3.06 1.9 9.7 13.4 99 3.08 B 1105

4.2+4.2 3.40 3.40 --- --- 1.97 6.80 7.00 0.41 2.51 2.66 1.8 11.0 11.7 99 2.71 D 1255

4.2+5.0 3.10 3.70 --- --- 1.97 6.80 7.62 0.38 2.41 3.12 1.7 10.6 13.7 99 2.82 C 1205

4.2+6.0 2.80 4.00 --- --- 2.28 6.80 7.92 0.43 2.21 3.06 1.9 9.7 13.4 99 3.08 B 1105

5.0+5.0 3.40 3.40 --- --- 2.36 6.80 8.06 0.47 2.31 3.35 2.1 10.1 14.7 99 2.94 C 1155

5.0+6.0 3.09 3.71 --- --- 2.49 6.80 8.28 0.48 2.12 3.28 2.1 9.3 14.4 99 3.21 A 1060

1.5+1.5+1.5 1.50 1.50 1.50 --- 1.98 4.50 6.11 0.42 1.03 1.68 1.8 4.5 7.4 99 4.37 A 515

1.5+1.5+2.0 1.50 1.50 2.00 --- 1.98 5.00 6.19 0.42 1.21 1.72 1.8 5.3 7.6 99 4.13 A 605

1.5+1.5+2.5 1.50 1.50 2.50 --- 1.98 5.50 6.74 0.42 1.44 2.03 1.8 6.3 8.9 99 3.82 A 720

1.5+1.5+3.5 1.50 1.50 3.50 --- 1.98 6.50 7.11 0.41 1.94 2.26 1.8 8.5 9.9 99 3.35 A 970

1.5+1.5+4.2 1.42 1.42 3.97 --- 1.98 6.80 7.32 0.41 2.12 2.40 1.8 9.3 10.5 99 3.21 A 1060

1.5+1.5+5.0 1.28 1.28 4.25 --- 1.98 6.80 7.72 0.39 2.02 2.59 1.7 8.9 11.4 99 3.37 A 1010

1.5+1.5+6.0 1.13 1.13 4.53 --- 2.33 6.80 8.04 0.44 1.88 2.59 1.9 8.3 11.4 99 3.62 A 940

1.5+2.0+2.0 1.50 2.00 2.00 --- 1.98 5.50 6.35 0.42 1.44 1.81 1.8 6.3 7.9 99 3.82 A 720

1.5+2.0+2.5 1.50 2.00 2.50 --- 1.98 6.00 6.74 0.42 1.68 2.03 1.8 7.4 8.9 99 3.57 A 840

1.5+2.0+3.5 1.46 1.94 3.40 --- 1.98 6.80 7.11 0.41 2.12 2.26 1.8 9.3 9.9 99 3.21 A 1060

1.5+2.0+4.2 1.32 1.77 3.71 --- 1.98 6.80 7.32 0.41 2.12 2.40 1.8 9.3 10.5 99 3.21 A 1060

1.5+2.0+5.0 1.20 1.60 4.00 --- 1.98 6.80 7.72 0.39 2.02 2.59 1.7 8.9 11.4 99 3.37 A 1010

1.5+2.0+6.0 1.07 1.43 4.29 --- 2.33 6.80 8.04 0.44 1.88 2.59 1.9 8.3 11.4 99 3.62 A 940

1.5+2.5+2.5 1.50 2.50 2.50 --- 1.98 6.50 6.96 0.41 1.94 2.16 1.8 8.5 9.5 99 3.35 A 970

1.5+2.5+3.5 1.36 2.27 3.17 --- 1.98 6.80 7.45 0.39 2.12 2.50 1.7 9.3 11.0 99 3.21 A 1060

1.5+2.5+4.2 1.24 2.07 3.48 --- 1.98 6.80 7.66 0.39 2.12 2.64 1.7 9.3 11.6 99 3.21 A 1060

1.5+2.5+5.0 1.13 1.89 3.78 --- 1.98 6.80 7.79 0.39 2.02 2.64 1.7 8.9 11.6 99 3.37 A 1010

1.5+2.5+6.0 1.02 1.70 4.08 --- 2.33 6.80 8.25 0.45 1.88 2.74 2.0 8.3 12.0 99 3.62 A 940

1.5+3.5+3.5 1.20 2.80 2.80 --- 1.98 6.80 7.46 0.40 2.12 2.50 1.8 9.3 11.0 99 3.21 A 1060

1.5+3.5+4.2 1.11 2.59 3.10 --- 1.98 6.80 7.67 0.40 2.12 2.64 1.8 9.3 11.6 99 3.21 A 1060

1.5+3.5+5.0 1.02 2.38 3.40 --- 2.30 6.80 8.29 0.44 2.02 3.06 1.9 8.9 13.4 99 3.37 A 1010

1.5+3.5+6.0 0.93 2.16 3.71 --- 2.33 6.80 9.04 0.45 1.88 3.44 2.0 8.3 15.1 99 3.62 A 940

1.5+4.2+4.2 1.03 2.88 2.88 --- 1.98 6.80 8.10 0.40 2.12 3.01 1.8 9.3 13.2 99 3.21 A 1060

1.5+4.2+5.0 0.95 2.67 3.18 --- 2.30 6.80 8.68 0.44 2.02 3.45 1.9 8.9 15.2 99 3.37 A 1010

2.0+2.0+2.0 2.00 2.00 2.00 --- 1.98 6.00 6.51 0.42 1.64 1.89 1.8 7.2 8.3 99 3.66 A 820

2.0+2.0+2.5 2.00 2.00 2.50 --- 1.98 6.50 6.89 0.42 1.89 2.12 1.8 8.3 9.3 99 3.44 A 945

2.0+2.0+3.5 1.81 1.81 3.18 --- 1.98 6.80 7.25 0.41 2.07 2.35 1.8 9.1 10.3 99 3.29 A 1035

2.0+2.0+4.2 1.66 1.66 3.48 --- 1.98 6.80 7.46 0.41 2.07 2.50 1.8 9.1 11.0 99 3.29 A 1035

2.0+2.0+5.0 1.51 1.51 3.78 --- 1.98 6.80 7.85 0.39 2.02 2.69 1.7 8.9 11.8 99 3.37 A 1010

2.0+2.0+6.0 1.36 1.36 4.08 --- 2.33 6.80 8.11 0.44 1.83 2.64 1.9 8.0 11.6 99 3.72 A 915

2.0+2.5+2.5 1.94 2.43 2.43 --- 1.98 6.80 7.10 0.41 2.07 2.26 1.8 9.1 9.9 99 3.29 A 1035

2.0+2.5+3.5 1.70 2.13 2.97 --- 1.98 6.80 7.59 0.39 2.07 2.59 1.7 9.1 11.4 99 3.29 A 1035

2.0+2.5+4.2 1.56 1.95 3.29 --- 1.98 6.80 7.78 0.39 2.07 2.75 1.7 9.1 12.1 99 3.29 A 1035

2.0+2.5+5.0 1.43 1.79 3.58 --- 1.98 6.80 7.92 0.39 2.02 2.74 1.7 8.9 12.0 99 3.37 A 1010

2.0+2.5+6.0 1.30 1.62 3.88 --- 2.33 6.80 8.38 0.45 1.83 2.84 2.0 8.0 12.5 99 3.72 A 915

2.0+3.5+3.5 1.52 2.64 2.64 --- 1.98 6.80 7.91 0.40 2.07 2.85 1.8 9.1 12.5 99 3.29 A 1035

2.0+3.5+4.2 1.40 2.45 2.95 --- 1.98 6.80 8.09 0.40 2.07 3.01 1.8 9.1 13.2 99 3.29 A 1035

2.0+3.5+5.0 1.30 2.27 3.23 --- 2.30 6.80 8.41 0.44 2.02 3.17 1.9 8.9 13.9 99 3.37 A 1010

2.0+4.2+4.2 1.30 2.75 2.75 --- 1.98 6.80 8.21 0.40 2.07 3.11 1.8 9.1 13.7 99 3.29 A 1035

2.5+2.5+2.5 2.26 2.26 2.26 --- 1.98 6.78 7.38 0.41 2.07 2.45 1.8 9.1 10.8 99 3.28 A 1035

2.5+2.5+3.5 2.00 2.00 2.80 --- 1.98 6.80 7.78 0.39 2.07 2.75 1.7 9.1 12.1 99 3.29 A 1035

2.5+2.5+4.2 1.85 1.85 3.10 --- 1.98 6.80 7.96 0.39 2.07 2.90 1.7 9.1 12.7 99 3.29 A 1035

2.5+2.5+5.0 1.70 1.70 3.40 --- 2.30 6.80 8.28 0.44 2.02 3.06 1.9 8.9 13.4 99 3.37 A 1010

2.5+2.5+6.0 1.55 1.55 3.70 --- 2.44 6.80 8.57 0.44 1.83 3.00 1.9 8.0 13.2 99 3.72 A 915

2.5+3.5+3.5 1.78 2.51 2.51 --- 2.29 6.80 8.14 0.44 2.07 3.06 1.9 9.1 13.4 99 3.29 A 1035

2.5+3.5+4.2 1.67 2.33 2.80 --- 2.29 6.80 8.26 0.44 2.07 3.17 1.9 9.1 13.9 99 3.29 A 1035

2.5+3.5+5.0 1.55 2.16 3.09 --- 2.51 6.80 8.57 0.46 1.98 3.33 2.0 8.7 14.6 99 3.43 A 990

2.5+4.2+4.2 1.56 2.62 2.62 --- 2.29 6.80 8.32 0.44 2.07 3.22 1.9 9.1 14.1 99 3.29 A 1035

3.5+3.5+3.5 2.26 2.26 2.26 --- 2.40 6.78 8.42 0.43 2.07 3.33 1.9 9.1 14.6 99 3.28 A 1035

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

96

3MXS-G

GC_pre2_lowres.pdf 96 30/11/2011 12:31:06

Page 99: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

3MXS68G2V1B

1.5 2.30 --- --- --- 1.51 2.30 3.34 0.44 0.65 0.99 2.0 2.9 4.4 98 3.54 B

2.0 2.72 --- --- --- 1.51 2.72 3.93 0.44 0.74 1.27 2.0 3.3 5.6 98 3.68 A

2.5 3.40 --- --- --- 1.47 3.40 4.13 0.43 1.03 1.37 1.9 4.6 6.1 98 3.30 C

3.5 4.30 --- --- --- 1.48 4.30 4.52 0.41 1.42 1.61 1.8 6.2 7.1 99 3.03 D

4.2 4.50 --- --- --- 1.48 4.50 4.71 0.41 1.51 1.72 1.8 6.6 7.6 99 2.98 D

5.0 5.60 --- --- --- 1.65 5.60 5.76 0.39 2.13 2.26 1.7 9.4 9.9 99 2.63 E

6.0 7.90 --- --- --- 1.92 7.90 8.57 0.41 2.65 2.92 1.8 11.6 12.8 99 2.98 D

1.5+1.5 2.90 2.90 --- --- 1.62 5.80 7.10 0.38 1.57 1.99 1.7 6.9 8.7 99 3.69 A

1.5+2.0 2.64 3.51 --- --- 1.62 6.15 7.10 0.38 1.72 1.99 1.7 7.6 8.7 99 3.58 B

1.5+2.5 2.44 4.06 --- --- 1.62 6.50 7.64 0.38 1.89 2.24 1.7 8.3 9.8 99 3.44 B

1.5+3.5 2.16 5.04 --- --- 1.76 7.20 8.17 0.39 2.25 2.55 1.7 9.9 11.2 99 3.20 D

1.5+4.2 2.02 5.67 --- --- 1.76 7.69 8.51 0.39 2.51 2.79 1.7 11.0 12.3 99 3.06 D

1.5+5.0 1.90 6.35 --- --- 2.14 8.25 9.98 0.48 2.63 3.16 2.1 11.6 13.9 99 3.14 D

1.5+6.0 1.72 6.88 --- --- 2.41 8.60 10.17 0.51 2.51 2.90 2.2 11.0 12.7 99 3.43 B

2.0+2.0 3.25 3.25 --- --- 1.62 6.50 7.64 0.38 1.87 2.25 1.7 8.2 9.9 99 3.48 B

2.0+2.5 3.04 3.81 --- --- 1.62 6.85 7.81 0.38 2.05 2.33 1.7 9.0 10.2 99 3.34 C

2.0+3.5 2.71 4.74 --- --- 1.76 7.45 8.34 0.39 2.34 2.64 1.7 10.3 11.6 99 3.18 D

2.0+4.2 2.58 5.42 --- --- 1.76 8.00 8.68 0.39 2.64 2.89 1.7 11.6 12.7 99 3.03 D

2.0+5.0 2.46 6.14 --- --- 2.14 8.60 10.15 0.48 2.80 3.26 2.1 12.3 14.3 99 3.07 D

2.0+6.0 2.15 6.45 --- --- 2.41 8.60 10.34 0.51 2.43 2.98 2.2 10.7 13.1 99 3.54 B

2.5+2.5 3.60 3.60 --- --- 1.62 7.20 8.16 0.38 2.24 2.56 1.7 9.8 11.2 99 3.21 C

2.5+3.5 3.29 4.61 --- --- 1.85 7.90 8.68 0.40 2.58 2.89 1.8 11.3 12.7 99 3.06 D

2.5+4.2 3.10 5.20 --- --- 1.85 8.30 8.93 0.40 2.80 3.07 1.8 12.3 13.5 99 2.96 D

2.5+5.0 2.87 5.73 --- --- 2.23 8.60 10.27 0.49 2.80 3.36 2.2 12.3 14.8 99 3.07 D

2.5+6.0 2.53 6.07 --- --- 2.50 8.60 10.46 0.53 2.43 3.01 2.3 10.7 13.2 99 3.54 B

3.5+3.5 4.30 4.30 --- --- 2.13 8.60 9.02 0.45 2.93 3.11 2.0 12.9 13.7 99 2.94 D

3.5+4.2 3.91 4.69 --- --- 2.13 8.60 9.11 0.45 2.92 3.16 2.0 12.8 13.9 99 2.95 D

3.5+5.0 3.54 5.06 --- --- 2.51 8.60 10.48 0.54 2.79 3.40 2.4 12.3 14.9 99 3.08 D

3.5+6.0 3.17 5.43 --- --- 2.69 8.60 10.59 0.55 2.42 3.00 2.4 10.6 13.2 99 3.55 B

4.2+4.2 4.30 4.30 --- --- 2.13 8.60 9.19 0.45 2.92 3.20 2.0 12.8 14.1 99 2.95 D

4.2+5.0 3.93 4.67 --- --- 2.51 8.60 10.49 0.54 2.79 3.47 2.4 12.3 15.2 99 3.08 D

4.2+6.0 3.54 5.06 --- --- 2.69 8.60 10.60 0.54 2.42 3.03 2.4 10.6 13.3 99 3.55 B

5.0+5.0 4.30 4.30 --- --- 2.88 8.60 10.67 0.63 2.70 3.38 2.8 11.9 14.8 99 3.19 D

5.0+6.0 3.91 4.69 --- --- 3.08 8.60 10.66 0.64 2.39 2.96 2.8 10.5 13.0 99 3.60 B

1.5+1.5+1.5 2.28 2.28 2.28 --- 1.97 6.83 9.37 0.44 1.63 2.38 1.9 7.2 10.5 99 4.19 A

1.5+1.5+2.0 2.15 2.15 2.87 --- 1.97 7.18 9.37 0.44 1.77 2.38 1.9 7.8 10.5 99 4.06 A

1.5+1.5+2.5 2.06 2.06 3.43 --- 2.06 7.54 9.96 0.45 1.89 2.65 2.0 8.3 11.6 99 3.99 A

1.5+1.5+3.5 1.90 1.90 4.44 --- 2.26 8.25 10.05 0.47 2.23 2.80 2.1 9.8 12.3 99 3.70 A

1.5+1.5+4.2 1.79 1.79 5.02 --- 2.26 8.60 10.06 0.47 2.38 2.79 2.1 10.5 12.3 99 3.61 A

1.5+1.5+5.0 1.61 1.61 5.38 --- 2.66 8.60 10.23 0.58 2.38 2.87 2.5 10.5 12.6 99 3.61 A

1.5+1.5+6.0 1.43 1.43 5.73 --- 2.87 8.60 10.44 0.58 2.16 2.63 2.5 9.5 11.6 99 3.98 A

1.5+2.0+2.0 2.06 2.74 2.74 --- 1.97 7.54 10.04 0.44 1.91 2.70 1.9 8.4 11.9 99 3.95 A

1.5+2.0+2.5 1.97 2.63 3.29 --- 2.06 7.89 10.04 0.45 2.03 2.69 2.0 8.9 11.8 99 3.89 A

1.5+2.0+3.5 1.84 2.46 4.30 --- 2.26 8.60 10.05 0.47 2.38 2.80 2.1 10.5 12.3 99 3.61 A

1.5+2.0+4.2 1.68 2.23 4.69 --- 2.26 8.60 10.06 0.47 2.38 2.79 2.1 10.5 12.3 99 3.61 A

1.5+2.0+5.0 1.52 2.02 5.06 --- 2.66 8.60 10.46 0.58 2.38 2.87 2.5 10.5 12.6 99 3.61 A

1.5+2.0+6.0 1.36 1.81 5.43 --- 2.87 8.60 10.55 0.58 2.16 2.63 2.5 9.5 11.6 99 3.98 A

1.5+2.5+2.5 1.90 3.17 3.17 --- 2.16 8.25 10.15 0.48 2.21 2.69 2.1 9.7 11.8 99 3.73 A

1.5+2.5+3.5 1.72 2.87 4.01 --- 2.35 8.60 10.17 0.50 2.38 2.79 2.2 10.5 12.3 99 3.61 A

1.5+2.5+4.2 1.57 2.62 4.40 --- 2.36 8.60 10.17 0.50 2.38 2.79 2.2 10.5 12.3 99 3.61 A

1.5+2.5+5.0 1.43 2.39 4.78 --- 2.75 8.60 10.58 0.60 2.38 2.87 2.6 10.5 12.6 99 3.61 A

1.5+2.5+6.0 1.29 2.15 5.16 --- 2.96 8.60 10.44 0.61 2.16 2.62 2.7 9.5 11.5 99 3.98 A

1.5+3.5+3.5 1.52 3.54 3.54 --- 2.64 8.60 10.18 0.58 2.38 2.79 2.5 10.5 12.3 99 3.61 A

1.5+3.5+4.2 1.40 3.27 3.93 --- 2.64 8.60 10.18 0.58 2.37 2.78 2.5 10.4 12.2 99 3.63 A

1.5+3.5+5.0 1.29 3.01 4.30 --- 2.94 8.60 10.59 0.66 2.37 2.86 2.9 10.4 12.6 99 3.63 A

1.5+3.5+6.0 1.17 2.74 4.69 --- 2.97 8.60 10.46 0.61 2.15 2.62 2.7 9.4 11.5 99 4.00 A

1.5+4.2+4.2 1.30 3.65 3.65 --- 2.64 8.60 10.19 0.58 2.37 2.78 2.5 10.4 12.2 99 3.63 A

1.5+4.2+5.0 1.21 3.38 4.02 --- 2.85 8.60 10.48 0.63 2.37 2.86 2.8 10.4 12.6 99 3.63 A

2.0+2.0+2.0 2.63 2.63 2.63 --- 1.97 7.89 10.04 0.44 2.05 2.70 1.9 9.0 11.9 99 3.85 A

2.0+2.0+2.5 2.54 2.54 3.17 --- 2.06 8.25 10.12 0.45 2.18 2.74 2.0 9.6 12.0 99 3.78 A

2.0+2.0+3.5 2.29 2.29 4.02 --- 2.26 8.60 10.22 0.47 2.34 2.88 2.1 10.3 12.6 99 3.68 A

2.0+2.0+4.2 2.10 2.10 4.40 --- 2.26 8.60 10.22 0.47 2.34 2.88 2.1 10.3 12.6 99 3.68 A

2.0+2.0+5.0 1.91 1.91 4.78 --- 2.66 8.60 10.40 0.58 2.34 2.96 2.5 10.3 13.0 99 3.68 A

2.0+2.0+6.0 1.72 1.72 5.16 --- 2.87 8.60 10.53 0.58 2.12 2.67 2.5 9.3 11.7 99 4.06 A

2.0+2.5+2.5 2.46 3.07 3.07 --- 2.16 8.60 10.13 0.46 2.35 2.84 2.0 10.3 12.5 99 3.66 A

2.0+2.5+3.5 2.15 2.69 3.76 --- 2.35 8.60 10.22 0.49 2.34 2.88 2.2 10.3 12.6 99 3.68 A

2.0+2.5+4.2 1.98 2.47 4.15 --- 2.36 8.60 10.23 0.49 2.34 2.87 2.2 10.3 12.6 99 3.68 A

2.0+2.5+5.0 1.81 2.26 4.53 --- 2.75 8.60 10.63 0.60 2.32 2.99 2.6 10.2 13.1 99 3.71 A

2.0+2.5+6.0 1.64 2.05 4.91 --- 2.96 8.60 10.64 0.60 2.10 2.64 2.6 9.2 11.6 99 4.10 A

2.0+3.5+3.5 1.92 3.34 3.34 --- 2.64 8.60 10.35 0.55 2.31 2.93 2.4 10.1 12.9 99 3.72 A

2.0+3.5+4.2 1.77 3.10 3.72 --- 2.64 8.60 10.35 0.55 2.31 2.92 2.4 10.1 12.8 99 3.72 A

2.0+3.5+5.0 1.64 2.87 4.09 --- 2.94 8.60 10.68 0.62 2.29 3.06 2.7 10.1 13.4 99 3.76 A

2.0+4.2+4.2 1.65 3.47 3.47 --- 2.64 8.60 10.36 0.55 2.31 2.92 2.4 10.1 12.8 99 3.72 A

2.5+2.5+2.5 2.86 2.86 2.86 --- 2.26 8.58 10.24 0.48 2.35 2.87 2.1 10.3 12.6 99 3.65 A

2.5+2.5+3.5 2.53 2.53 3.54 --- 2.45 8.60 10.45 0.51 2.34 2.96 2.2 10.3 13.0 99 3.68 A

2.5+2.5+4.2 2.34 2.34 3.93 --- 2.45 8.60 10.46 0.51 2.34 2.96 2.2 10.3 13.0 99 3.68 A

2.5+2.5+5.0 2.15 2.15 4.30 --- 2.85 8.60 10.64 0.62 2.29 3.02 2.7 10.1 13.3 99 3.76 A

2.5+2.5+6.0 1.95 1.95 4.70 --- 3.06 8.60 10.65 0.62 2.08 2.64 2.7 9.1 11.6 99 4.13 A

2.5+3.5+3.5 2.26 3.17 3.17 --- 2.73 8.60 10.58 0.56 2.31 2.96 2.5 10.1 13.0 99 3.72 A

2.5+3.5+4.2 2.11 2.95 3.54 --- 2.74 8.60 10.59 0.56 2.31 2.95 2.5 10.1 13.0 99 3.72 A

2.5+3.5+5.0 1.95 2.74 3.91 --- 3.13 8.60 10.65 0.64 2.29 2.98 2.8 10.1 13.1 99 3.76 A

2.5+4.2+4.2 1.97 3.31 3.31 --- 2.74 8.60 10.59 0.56 2.31 2.95 2.5 10.1 13.0 99 3.72 A

3.5+3.5+3.5 2.86 2.86 2.86 --- 2.92 8.58 10.63 0.61 2.29 3.03 2.7 10.1 13.3 99 3.75 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

97

3MXS-G

GC_pre2_lowres.pdf 97 30/11/2011 12:31:06

Page 100: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS68F2V1B

1.5 1.50 --- --- --- 1.43 1.50 2.46 0.44 0.47 0.55 2.0 2.1 2.5 96 3.19 B 235

2.0 2.00 --- --- --- 1.57 2.00 2.63 0.44 0.47 0.62 2.0 2.1 2.8 96 4.26 A 235

2.5 2.50 --- --- --- 1.57 2.50 3.37 0.46 0.59 0.85 2.1 2.7 3.8 96 4.24 A 295

3.5 3.50 --- --- --- 1.57 3.50 4.76 0.47 0.91 1.47 2.1 4.0 6.5 98 3.85 A 455

4.2 4.20 --- --- --- 1.95 4.20 5.02 0.47 1.21 1.62 2.1 5.4 7.2 98 3.47 A 605

5.0 5.00 --- --- --- 1.96 5.00 5.91 0.45 1.71 2.20 2.0 7.5 9.7 99 2.92 C 855

6.0 6.00 --- --- --- 1.96 6.00 6.38 0.44 2.05 2.32 1.9 9.0 10.2 99 2.93 C 1025

1.5+1.5 1.50 1.50 --- --- 1.97 3.00 4.70 0.43 0.65 1.29 1.9 2.9 5.7 99 4.62 A 325

1.5+2.0 1.50 2.00 --- --- 1.97 3.50 4.86 0.43 0.80 1.37 1.9 3.5 6.0 99 4.38 A 400

1.5+2.5 1.50 2.50 --- --- 1.97 4.00 5.18 0.43 0.99 1.53 1.9 4.3 6.7 99 4.04 A 495

1.5+3.5 1.50 3.50 --- --- 1.97 5.00 6.05 0.42 1.39 2.06 1.8 6.1 9.0 99 3.60 A 695

1.5+4.2 1.50 4.20 --- --- 1.97 5.70 6.26 0.42 1.79 2.20 1.8 7.9 9.7 99 3.18 B 895

1.5+5.0 1.50 5.00 --- --- 1.97 6.50 6.94 0.41 2.22 2.51 1.8 9.7 11.0 99 2.93 C 1110

1.5+6.0 1.36 5.44 --- --- 1.98 6.80 7.44 0.40 2.26 2.65 1.8 9.9 11.6 99 3.01 B 1130

2.0+2.0 2.00 2.00 --- --- 1.97 4.00 5.02 0.43 1.00 1.45 1.9 4.4 6.4 99 4.00 A 500

2.0+2.5 2.00 2.50 --- --- 1.97 4.50 5.33 0.43 1.20 1.61 1.9 5.3 7.1 99 3.75 A 600

2.0+3.5 2.00 3.50 --- --- 1.97 5.50 6.18 0.42 1.66 2.15 1.8 7.3 9.4 99 3.31 A 830

2.0+4.2 2.00 4.20 --- --- 1.97 6.20 6.38 0.42 2.09 2.30 1.8 9.2 10.1 99 2.97 C 1045

2.0+5.0 1.94 4.86 --- --- 1.97 6.80 7.12 0.41 2.41 2.65 1.8 10.6 11.6 99 2.82 C 1205

2.0+6.0 1.70 5.10 --- --- 1.98 6.80 7.56 0.40 2.21 2.75 1.8 9.7 12.1 99 3.08 B 1105

2.5+2.5 2.50 2.50 --- --- 1.97 5.00 5.98 0.45 1.46 2.00 2.0 6.4 8.8 99 3.42 A 730

2.5+3.5 2.50 3.50 --- --- 1.97 6.00 6.44 0.43 2.06 2.37 1.9 9.0 10.4 99 2.91 C 1030

2.5+4.2 2.50 4.20 --- --- 1.97 6.70 6.81 0.43 2.54 2.67 1.9 11.2 11.7 99 2.64 D 1270

2.5+5.0 2.27 4.53 --- --- 1.97 6.80 7.23 0.40 2.41 2.75 1.8 10.6 12.1 99 2.82 C 1205

2.5+6.0 2.00 4.80 --- --- 1.98 6.80 7.56 0.38 2.21 2.75 1.7 9.7 12.1 99 3.08 B 1105

3.5+3.5 3.40 3.40 --- --- 1.97 6.80 6.99 0.41 2.51 2.66 1.8 11.0 11.7 99 2.71 D 1255

3.5+4.2 3.09 3.71 --- --- 1.97 6.80 7.10 0.41 2.51 2.76 1.8 11.0 12.1 99 2.71 D 1255

3.5+5.0 2.80 4.00 --- --- 1.97 6.80 7.61 0.38 2.41 3.12 1.7 10.6 13.7 99 2.82 C 1205

3.5+6.0 2.51 4.29 --- --- 2.28 6.80 7.91 0.43 2.21 3.06 1.9 9.7 13.4 99 3.08 B 1105

4.2+4.2 3.40 3.40 --- --- 1.97 6.80 7.00 0.41 2.51 2.66 1.8 11.0 11.7 99 2.71 D 1255

4.2+5.0 3.10 3.70 --- --- 1.97 6.80 7.62 0.38 2.41 3.12 1.7 10.6 13.7 99 2.82 C 1205

4.2+6.0 2.80 4.00 --- --- 2.28 6.80 7.92 0.43 2.21 3.06 1.9 9.7 13.4 99 3.08 B 1105

5.0+5.0 3.40 3.40 --- --- 2.36 6.80 8.06 0.47 2.31 3.35 2.1 10.1 14.7 99 2.94 C 1155

5.0+6.0 3.09 3.71 --- --- 2.49 6.80 8.28 0.48 2.12 3.28 2.1 9.3 14.4 99 3.21 A 1060

1.5+1.5+1.5 1.50 1.50 1.50 --- 1.98 4.50 6.27 0.42 1.03 1.76 1.8 4.5 7.7 99 4.37 A 515

1.5+1.5+2.0 1.50 1.50 2.00 --- 1.98 5.00 6.43 0.42 1.21 1.85 1.8 5.3 8.1 99 4.13 A 605

1.5+1.5+2.5 1.50 1.50 2.50 --- 1.98 5.50 6.59 0.42 1.44 1.94 1.8 6.3 8.5 99 3.82 A 720

1.5+1.5+3.5 1.50 1.50 3.50 --- 1.98 6.50 6.97 0.41 1.94 2.16 1.8 8.5 9.5 99 3.35 A 970

1.5+1.5+4.2 1.42 1.42 3.97 --- 1.98 6.80 7.19 0.41 2.12 2.30 1.8 9.3 10.1 99 3.21 A 1060

1.5+1.5+5.0 1.28 1.28 4.25 --- 1.98 6.80 7.59 0.39 2.02 2.49 1.7 8.9 10.9 99 3.37 A 1010

1.5+1.5+6.0 1.13 1.13 4.53 --- 2.33 6.80 7.83 0.44 1.88 2.44 1.9 8.3 10.7 99 3.62 A 940

1.5+2.0+2.0 1.50 2.00 2.00 --- 1.98 5.50 6.35 0.42 1.44 1.81 1.8 6.3 7.9 99 3.82 A 720

1.5+2.0+2.5 1.50 2.00 2.50 --- 1.98 6.00 6.74 0.42 1.68 2.03 1.8 7.4 8.9 99 3.57 A 840

1.5+2.0+3.5 1.46 1.94 3.40 --- 1.98 6.80 7.11 0.41 2.12 2.26 1.8 9.3 9.9 99 3.21 A 1060

1.5+2.0+4.2 1.32 1.77 3.71 --- 1.98 6.80 7.32 0.41 2.12 2.40 1.8 9.3 10.5 99 3.21 A 1060

1.5+2.0+5.0 1.20 1.60 4.00 --- 1.98 6.80 7.72 0.39 2.02 2.59 1.7 8.9 11.4 99 3.37 A 1010

1.5+2.0+6.0 1.07 1.43 4.29 --- 2.33 6.80 7.97 0.44 1.88 2.54 1.9 8.3 11.2 99 3.62 A 940

1.5+2.5+2.5 1.50 2.50 2.50 --- 1.98 6.50 6.96 0.41 1.94 2.16 1.8 8.5 9.5 99 3.35 A 970

1.5+2.5+3.5 1.36 2.27 3.17 --- 1.98 6.80 7.45 0.39 2.12 2.50 1.7 9.3 11.0 99 3.21 A 1060

1.5+2.5+4.2 1.24 2.07 3.48 --- 1.98 6.80 7.66 0.39 2.12 2.64 1.7 9.3 11.6 99 3.21 A 1060

1.5+2.5+5.0 1.13 1.89 3.78 --- 1.98 6.80 7.79 0.39 2.02 2.64 1.7 8.9 11.6 99 3.37 A 1010

1.5+2.5+6.0 1.02 1.70 4.08 --- 2.33 6.80 8.25 0.45 1.88 2.74 2.0 8.3 12.0 99 3.62 A 940

1.5+3.5+3.5 1.20 2.80 2.80 --- 1.98 6.80 7.78 0.40 2.12 2.75 1.8 9.3 12.1 99 3.21 A 1060

1.5+3.5+4.2 1.11 2.59 3.10 --- 1.98 6.80 7.97 0.40 2.12 2.90 1.8 9.3 12.7 99 3.21 A 1060

1.5+3.5+5.0 1.02 2.38 3.40 --- 1.98 6.80 8.29 0.36 2.02 3.06 1.6 8.9 13.4 99 3.37 A 1010

1.5+3.5+6.0 0.93 2.16 3.71 --- 2.33 6.80 8.39 0.45 1.88 2.84 2.0 8.3 12.5 99 3.62 A 940

1.5+4.2+4.2 1.03 2.88 2.88 --- 1.98 6.80 8.10 0.40 2.12 3.01 1.8 9.3 13.2 99 3.21 A 1060

1.5+4.2+5.0 0.95 2.67 3.18 --- 1.98 6.80 8.36 0.36 2.02 3.11 1.6 8.9 13.7 99 3.37 A 1010

2.0+2.0+2.0 2.00 2.00 2.00 --- 1.98 6.00 6.51 0.42 1.64 1.89 1.8 7.2 8.3 99 3.66 A 820

2.0+2.0+2.5 2.00 2.00 2.50 --- 1.98 6.50 6.89 0.42 1.89 2.12 1.8 8.3 9.3 99 3.44 A 945

2.0+2.0+3.5 1.81 1.81 3.18 --- 1.98 6.80 7.25 0.41 2.07 2.35 1.8 9.1 10.3 99 3.29 A 1035

2.0+2.0+4.2 1.66 1.66 3.48 --- 1.98 6.80 7.46 0.41 2.07 2.50 1.8 9.1 11.0 99 3.29 A 1035

2.0+2.0+5.0 1.51 1.51 3.78 --- 1.98 6.80 7.85 0.39 2.02 2.69 1.7 8.9 11.8 99 3.37 A 1010

2.0+2.0+6.0 1.36 1.36 4.08 --- 2.33 6.80 8.11 0.44 1.83 2.64 1.9 8.0 11.6 99 3.72 A 915

2.0+2.5+2.5 1.94 2.43 2.43 --- 1.98 6.80 7.10 0.41 2.07 2.26 1.8 9.1 9.9 99 3.29 A 1035

2.0+2.5+3.5 1.70 2.13 2.97 --- 1.98 6.80 7.59 0.39 2.07 2.59 1.7 9.1 11.4 99 3.29 A 1035

2.0+2.5+4.2 1.56 1.95 3.29 --- 1.98 6.80 7.78 0.39 2.07 2.75 1.7 9.1 12.1 99 3.29 A 1035

2.0+2.5+5.0 1.43 1.79 3.58 --- 1.98 6.80 7.92 0.39 2.02 2.74 1.7 8.9 12.0 99 3.37 A 1010

2.0+2.5+6.0 1.30 1.62 3.88 --- 2.33 6.80 8.38 0.45 1.83 2.84 2.0 8.0 12.5 99 3.72 A 915

2.0+3.5+3.5 1.52 2.64 2.64 --- 1.98 6.80 7.91 0.40 2.07 2.85 1.8 9.1 12.5 99 3.29 A 1035

2.0+3.5+4.2 1.40 2.45 2.94 --- 1.98 6.80 8.09 0.40 2.07 3.01 1.8 9.1 13.2 99 3.29 A 1035

2.0+3.5+5.0 1.30 2.27 3.23 --- 2.30 6.80 8.41 0.44 2.02 3.17 1.9 8.9 13.9 99 3.37 A 1010

2.0+4.2+4.2 1.30 2.75 2.75 --- 1.98 6.80 8.21 0.40 2.07 3.11 1.8 9.1 13.7 99 3.29 A 1035

2.5+2.5+2.5 2.26 2.26 2.26 --- 1.98 6.78 7.38 0.41 2.07 2.45 1.8 9.1 10.8 99 3.28 A 1035

2.5+2.5+3.5 2.00 2.00 2.80 --- 1.98 6.80 7.78 0.39 2.07 2.75 1.7 9.1 12.1 99 3.29 A 1035

2.5+2.5+4.2 1.85 1.85 3.10 --- 1.98 6.80 7.96 0.39 2.07 2.90 1.7 9.1 12.7 99 3.29 A 1035

2.5+2.5+5.0 1.70 1.70 3.40 --- 2.30 6.80 8.28 0.44 2.02 3.06 1.9 8.9 13.4 99 3.37 A 1010

2.5+2.5+6.0 1.55 1.55 3.70 --- 2.44 6.80 8.57 0.44 1.83 3.00 1.9 8.0 13.2 99 3.72 A 915

2.5+3.5+3.5 1.78 2.51 2.51 --- 2.29 6.80 8.14 0.44 2.07 3.06 1.9 9.1 13.4 99 3.29 A 1035

2.5+3.5+4.2 1.67 2.33 2.80 --- 2.29 6.80 8.26 0.44 2.07 3.17 1.9 9.1 13.9 99 3.29 A 1035

2.5+3.5+5.0 1.55 2.16 3.09 --- 2.51 6.80 8.57 0.46 1.98 3.33 2.0 8.7 14.6 99 3.43 A 990

2.5+4.2+4.2 1.56 2.62 2.62 --- 2.29 6.80 8.32 0.44 2.07 3.22 1.9 9.1 14.1 99 3.29 A 1035

3.5+3.5+3.5 2.26 2.26 2.26 --- 2.40 6.78 8.42 0.43 2.07 3.33 1.9 9.1 14.6 99 3.28 A 1035

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

98

4MXS-F

GC_pre2_lowres.pdf 98 30/11/2011 12:31:07

Page 101: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS68F2V1B

1.5+1.5+1.5+1.5 1.50 1.50 1.50 1.50 1.99 6.00 6.95 0.41 1.42 1.83 1.8 6.2 8.0 96 4.23 A 710

1.5+1.5+1.5+2.0 1.50 1.50 1.50 2.00 1.99 6.50 7.13 0.41 1.62 1.91 1.8 7.1 8.4 96 4.01 A 810

1.5+1.5+1.5+2.5 1.46 1.46 1.46 2.43 1.99 6.80 7.30 0.39 1.73 2.00 1.7 7.6 8.8 96 3.93 A 865

1.5+1.5+1.5+3.5 1.28 1.28 1.28 2.98 1.99 6.80 7.72 0.40 1.71 2.24 1.8 7.5 9.8 98 3.98 A 855

1.5+1.5+1.5+4.2 1.17 1.17 1.17 3.28 1.99 6.80 7.88 0.40 1.71 2.33 1.8 7.5 10.2 98 3.98 A 855

1.5+1.5+1.5+5.0 1.07 1.07 1.07 3.58 2.47 6.80 8.31 0.46 1.71 2.61 2.0 7.5 11.5 99 3.98 A 855

1.5+1.5+1.5+6.0 0.97 0.97 0.97 3.89 2.50 6.80 8.22 0.43 1.57 2.34 1.9 6.9 10.3 99 4.33 A 785

1.5+1.5+2.0+2.0 1.46 1.46 1.94 1.94 1.99 6.80 7.30 0.41 1.75 2.00 1.8 7.7 8.8 99 3.89 A 875

1.5+1.5+2.0+2.5 1.36 1.36 1.81 2.27 1.99 6.80 7.47 0.39 1.73 2.10 1.7 7.6 9.2 99 3.93 A 865

1.5+1.5+2.0+3.5 1.20 1.20 1.60 2.80 1.99 6.80 7.87 0.40 1.71 2.33 1.8 7.5 10.2 99 3.98 A 855

1.5+1.5+2.0+4.2 1.11 1.11 1.48 3.10 1.99 6.80 8.03 0.40 1.71 2.43 1.8 7.5 10.7 99 3.98 A 855

1.5+1.5+2.0+5.0 1.02 1.02 1.36 3.40 2.47 6.80 8.46 0.46 1.71 2.71 2.0 7.5 11.9 99 3.98 A 855

1.5+1.5+2.0+6.0 0.93 0.93 1.24 3.71 2.50 6.80 8.39 0.43 1.57 2.45 1.9 6.9 10.8 99 4.33 A 785

1.5+1.5+2.5+2.5 1.28 1.28 2.13 2.13 1.99 6.80 7.55 0.39 1.73 2.14 1.7 7.6 9.4 99 3.93 A 865

1.5+1.5+2.5+3.5 1.13 1.13 1.89 2.64 2.34 6.80 7.95 0.50 1.71 2.38 2.2 7.5 10.5 99 3.98 A 855

1.5+1.5+2.5+4.2 1.05 1.05 1.75 2.94 2.34 6.80 8.11 0.50 1.71 2.48 2.2 7.5 10.9 99 3.98 A 855

1.5+1.5+2.5+5.0 0.97 0.97 1.62 3.24 2.47 6.80 8.53 0.46 1.71 2.76 2.0 7.5 12.1 99 3.98 A 855

1.5+1.5+3.5+3.5 1.02 1.02 2.38 2.38 2.34 6.80 8.40 0.50 1.71 2.68 2.2 7.5 11.8 99 3.98 A 855

1.5+1.5+3.5+4.2 0.95 0.95 2.22 2.67 2.46 6.80 8.48 0.54 1.71 2.74 2.4 7.5 12.0 99 3.98 A 855

1.5+2.0+2.0+2.0 1.36 1.81 1.81 1.81 1.99 6.80 7.46 0.41 1.75 2.10 1.8 7.7 9.2 99 3.89 A 875

1.5+2.0+2.0+2.5 1.28 1.70 1.70 2.13 1.99 6.80 7.63 0.39 1.73 2.19 1.7 7.6 9.6 99 3.93 A 865

1.5+2.0+2.0+3.5 1.13 1.51 1.51 2.64 2.34 6.80 8.02 0.50 1.71 2.43 2.2 7.5 10.7 99 3.98 A 855

1.5+2.0+2.0+4.2 1.05 1.40 1.40 2.94 2.34 6.80 8.18 0.50 1.71 2.53 2.2 7.5 11.1 99 3.98 A 855

1.5+2.0+2.0+5.0 0.97 1.30 1.30 3.24 2.47 6.80 8.60 0.46 1.71 2.82 2.0 7.5 12.4 99 3.98 A 855

1.5+2.0+2.5+2.5 1.20 1.60 2.00 2.00 1.99 6.80 7.71 0.39 1.73 2.24 1.7 7.6 9.8 99 3.93 A 865

1.5+2.0+2.5+3.5 1.07 1.43 1.79 2.51 2.34 6.80 8.10 0.50 1.71 2.48 2.2 7.5 10.9 99 3.98 A 855

1.5+2.0+2.5+4.2 1.00 1.33 1.67 2.80 2.34 6.80 8.26 0.50 1.71 2.58 2.2 7.5 11.3 99 3.98 A 855

1.5+2.0+2.5+5.0 0.93 1.24 1.55 3.09 2.47 6.80 8.68 0.46 1.71 2.87 2.0 7.5 12.6 99 3.98 A 855

1.5+2.0+3.5+3.5 0.97 1.30 2.27 2.27 2.00 6.80 8.47 0.40 1.71 2.74 1.8 7.5 12.0 99 3.98 A 855

1.5+2.5+2.5+2.5 1.13 1.89 1.89 1.89 1.99 6.80 8.02 0.36 1.71 2.43 1.6 7.5 10.7 99 3.98 A 855

1.5+2.5+2.5+3.5 1.02 1.70 1.70 2.38 2.34 6.80 8.32 0.43 1.70 2.63 1.9 7.5 11.6 99 4.00 A 850

1.5+2.5+2.5+4.2 0.95 1.59 1.59 2.67 2.34 6.80 8.33 0.45 1.73 2.63 2.0 7.6 11.6 99 3.93 A 865

1.5+2.5+3.5+3.5 0.93 1.55 2.16 2.16 2.34 6.80 8.54 0.43 1.70 2.79 1.9 7.5 12.3 99 4.00 A 850

2.0+2.0+2.0+2.0 1.70 1.70 1.70 1.70 1.99 6.80 7.63 0.41 1.75 2.19 1.8 7.7 9.6 99 3.89 A 875

2.0+2.0+2.0+2.5 1.60 1.60 1.60 2.00 1.99 6.80 7.79 0.39 1.73 2.29 1.7 7.6 10.1 99 3.93 A 865

2.0+2.0+2.0+3.5 1.43 1.43 1.43 2.51 1.99 6.80 8.17 0.40 1.71 2.53 1.8 7.5 11.1 99 3.98 A 855

2.0+2.0+2.0+4.2 1.33 1.33 1.33 2.81 1.99 6.80 8.32 0.40 1.71 2.63 1.8 7.5 11.6 99 3.98 A 855

2.0+2.0+2.0+5.0 1.24 1.24 1.24 3.08 2.47 6.80 8.74 0.46 1.67 2.93 2.0 7.3 12.9 99 4.07 A 835

2.0+2.0+2.5+2.5 1.51 1.51 1.89 1.89 1.99 6.80 7.94 0.40 1.75 2.38 1.8 7.7 10.5 99 3.89 A 875

2.0+2.0+2.5+3.5 1.36 1.36 1.70 2.38 2.34 6.80 8.32 0.45 1.73 2.63 2.0 7.6 11.6 99 3.93 A 865

2.0+2.0+2.5+4.2 1.27 1.27 1.59 2.67 2.34 6.80 8.47 0.45 1.73 2.74 2.0 7.6 12.0 99 3.93 A 865

2.0+2.0+3.5+3.5 1.24 1.24 2.16 2.16 2.46 6.80 8.61 0.45 1.71 2.84 2.0 7.5 12.5 99 3.98 A 855

2.0+2.5+2.5+2.5 1.43 1.79 1.79 1.79 1.99 6.80 8.17 0.40 1.75 2.53 1.8 7.7 11.1 99 3.89 A 875

2.0+2.5+2.5+3.5 1.30 1.62 1.62 2.26 2.34 6.80 8.46 0.45 1.73 2.74 2.0 7.6 12.0 99 3.93 A 865

2.5+2.5+2.5+2.5 1.70 1.70 1.70 1.70 2.34 6.80 8.39 0.46 1.71 2.68 2.0 7.5 11.8 99 3.98 A 855

2.5+2.5+2.5+3.5 1.55 1.55 1.55 2.15 2.46 6.80 8.73 0.46 1.70 2.95 2.0 7.5 13.0 99 4.00 A 850

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

99

4MXS-F

GC_pre2_lowres.pdf 99 30/11/2011 12:31:07

Page 102: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS68F2V1B

1.5 2.30 --- --- --- 1.51 2.30 3.34 0.44 0.65 0.99 2.0 2.9 4.4 98 3.54 B

2.0 2.72 --- --- --- 1.51 2.72 3.93 0.44 0.74 1.27 2.0 3.3 5.6 98 3.68 A

2.5 3.40 --- --- --- 1.47 3.40 4.13 0.43 1.03 1.37 1.9 4.6 6.1 98 3.30 C

3.5 4.30 --- --- --- 1.48 4.30 4.52 0.41 1.42 1.61 1.8 6.2 7.1 99 3.03 D

4.2 4.50 --- --- --- 1.48 4.50 4.71 0.41 1.51 1.72 1.8 6.6 7.6 99 2.98 D

5.0 5.60 --- --- --- 1.65 5.60 5.76 0.39 2.13 2.26 1.7 9.4 9.9 99 2.63 E

6.0 7.90 --- --- --- 1.92 7.90 8.57 0.41 2.65 2.92 1.8 11.6 12.8 99 2.98 D

1.5+1.5 2.62 2.62 --- --- 1.62 5.24 7.10 0.38 1.32 1.99 1.7 5.8 8.7 99 3.97 A

1.5+2.0 2.43 3.23 --- --- 1.62 5.66 7.46 0.38 1.50 2.16 1.7 6.6 9.5 99 3.77 A

1.5+2.5 2.28 3.80 --- --- 1.62 6.08 7.64 0.38 1.70 2.24 1.7 7.5 9.8 99 3.58 B

1.5+3.5 2.08 4.84 --- --- 1.76 6.92 8.17 0.39 2.09 2.55 1.7 9.2 11.2 99 3.31 C

1.5+4.2 1.98 5.53 --- --- 1.76 7.51 8.51 0.39 2.38 2.79 1.7 10.5 12.3 99 3.16 D

1.5+5.0 1.89 6.29 --- --- 2.14 8.18 9.98 0.48 2.58 3.16 2.1 11.3 13.9 99 3.17 D

1.5+6.0 1.72 6.88 --- --- 2.41 8.60 10.17 0.51 2.51 2.90 2.2 11.0 12.7 99 3.43 B

2.0+2.0 3.25 3.25 --- --- 1.62 6.50 7.64 0.38 1.87 2.25 1.7 8.2 9.9 99 3.48 B

2.0+2.5 3.04 3.81 --- --- 1.62 6.85 7.81 0.38 2.05 2.33 1.7 9.0 10.2 99 3.34 C

2.0+3.5 2.71 4.74 --- --- 1.76 7.45 8.34 0.39 2.34 2.64 1.7 10.3 11.6 99 3.18 D

2.0+4.2 2.58 5.42 --- --- 1.76 8.00 8.68 0.39 2.64 2.89 1.7 11.6 12.7 99 3.03 D

2.0+5.0 2.46 6.14 --- --- 2.14 8.60 10.15 0.48 2.80 3.26 2.1 12.3 14.3 99 3.07 D

2.0+6.0 2.15 6.45 --- --- 2.41 8.60 10.34 0.51 2.43 2.98 2.2 10.7 13.1 99 3.54 B

2.5+2.5 3.60 3.60 --- --- 1.62 7.20 8.16 0.38 2.24 2.56 1.7 9.8 11.2 99 3.21 C

2.5+3.5 3.29 4.61 --- --- 1.85 7.90 8.68 0.40 2.58 2.89 1.8 11.3 12.7 99 3.06 D

2.5+4.2 3.10 5.20 --- --- 1.85 8.30 8.93 0.40 2.80 3.07 1.8 12.3 13.5 99 2.96 D

2.5+5.0 2.87 5.73 --- --- 2.23 8.60 10.27 0.49 2.80 3.36 2.2 12.3 14.8 99 3.07 D

2.5+6.0 2.53 6.07 --- --- 2.50 8.60 10.46 0.53 2.43 3.01 2.3 10.7 13.2 99 3.54 B

3.5+3.5 4.30 4.30 --- --- 2.13 8.60 9.02 0.45 2.93 3.11 2.0 12.9 13.7 99 2.94 D

3.5+4.2 3.91 4.69 --- --- 2.13 8.60 9.11 0.45 2.92 3.16 2.0 12.8 13.9 99 2.95 D

3.5+5.0 3.54 5.06 --- --- 2.51 8.60 10.48 0.54 2.79 3.40 2.4 12.3 14.9 99 3.08 D

3.5+6.0 3.17 5.43 --- --- 2.69 8.60 10.59 0.55 2.42 3.00 2.4 10.6 13.2 99 3.55 B

4.2+4.2 4.30 4.30 --- --- 2.13 8.60 9.19 0.45 2.92 3.20 2.0 12.8 14.1 99 2.95 D

4.2+5.0 3.93 4.67 --- --- 2.51 8.60 10.49 0.54 2.79 3.47 2.4 12.3 15.2 99 3.08 D

4.2+6.0 3.54 5.06 --- --- 2.69 8.60 10.60 0.54 2.42 3.03 2.4 10.6 13.3 99 3.55 B

5.0+5.0 4.30 4.30 --- --- 2.88 8.60 10.67 0.63 2.70 3.38 2.8 11.9 14.8 99 3.19 D

5.0+6.0 3.91 4.69 --- --- 3.08 8.60 10.66 0.64 2.39 2.96 2.8 10.5 13.0 99 3.60 B

1.5+1.5+1.5 2.17 2.17 2.17 --- 1.97 6.50 9.54 0.44 1.50 2.46 1.9 6.6 10.8 99 4.33 A

1.5+1.5+2.0 2.08 2.08 2.77 --- 1.97 6.92 9.71 0.44 1.67 2.54 1.9 7.3 11.2 99 4.14 A

1.5+1.5+2.5 2.00 2.00 3.34 --- 2.06 7.34 9.79 0.45 1.82 2.58 2.0 8.0 11.3 99 4.03 A

1.5+1.5+3.5 1.89 1.89 4.40 --- 2.26 8.18 9.89 0.47 2.19 2.71 2.1 9.6 11.9 99 3.74 A

1.5+1.5+4.2 1.79 1.79 5.02 --- 2.26 8.60 9.89 0.47 2.38 2.71 2.1 10.5 11.9 99 3.61 A

1.5+1.5+5.0 1.61 1.61 5.38 --- 2.66 8.60 10.06 0.58 2.38 2.79 2.5 10.5 12.3 99 3.61 A

1.5+1.5+6.0 1.43 1.43 5.73 --- 2.87 8.60 10.18 0.58 2.16 2.51 2.5 9.5 11.0 99 3.98 A

1.5+2.0+2.0 2.00 2.67 2.67 --- 1.97 7.34 9.87 0.44 1.84 2.62 1.9 8.1 11.5 99 3.99 A

1.5+2.0+2.5 1.94 2.59 3.23 --- 2.06 7.76 9.96 0.45 2.00 2.65 2.0 8.8 11.6 99 3.88 A

1.5+2.0+3.5 1.84 2.46 4.30 --- 2.26 8.60 10.05 0.47 2.38 2.80 2.1 10.5 12.3 99 3.61 A

1.5+2.0+4.2 1.68 2.23 4.69 --- 2.26 8.60 10.06 0.47 2.38 2.79 2.1 10.5 12.3 99 3.61 A

1.5+2.0+5.0 1.52 2.02 5.06 --- 2.66 8.60 10.46 0.58 2.38 2.87 2.5 10.5 12.6 99 3.61 A

1.5+2.0+6.0 1.36 1.81 5.43 --- 2.87 8.60 10.47 0.58 2.16 2.59 2.5 9.5 11.4 99 3.98 A

1.5+2.5+2.5 1.89 3.15 3.15 --- 2.16 8.18 10.07 0.48 2.18 2.65 2.1 9.6 11.6 99 3.75 A

1.5+2.5+3.5 1.72 2.87 4.01 --- 2.35 8.60 10.17 0.50 2.38 2.79 2.2 10.5 12.3 99 3.61 A

1.5+2.5+4.2 1.57 2.62 4.40 --- 2.36 8.60 10.17 0.50 2.38 2.79 2.2 10.5 12.3 99 3.61 A

1.5+2.5+5.0 1.43 2.39 4.78 --- 2.75 8.60 10.58 0.60 2.38 2.87 2.6 10.5 12.6 99 3.61 A

1.5+2.5+6.0 1.29 2.15 5.16 --- 2.96 8.60 10.36 0.61 2.16 2.59 2.7 9.5 11.4 99 3.98 A

1.5+3.5+3.5 1.52 3.54 3.54 --- 2.64 8.60 10.18 0.58 2.38 2.79 2.5 10.5 12.3 99 3.61 A

1.5+3.5+4.2 1.40 3.27 3.93 --- 2.64 8.60 10.18 0.58 2.37 2.78 2.5 10.4 12.2 99 3.63 A

1.5+3.5+5.0 1.29 3.01 4.30 --- 2.94 8.60 10.51 0.66 2.37 2.82 2.9 10.4 12.4 99 3.63 A

1.5+3.5+6.0 1.17 2.74 4.69 --- 2.87 8.60 10.37 0.58 2.15 2.58 2.5 9.4 11.3 99 4.00 A

1.5+4.2+4.2 1.30 3.65 3.65 --- 2.64 8.60 10.27 0.58 2.37 2.82 2.5 10.4 12.4 99 3.63 A

1.5+4.2+5.0 1.21 3.38 4.02 --- 2.94 8.60 10.57 0.66 2.37 2.90 2.9 10.4 12.7 99 3.63 A

2.0+2.0+2.0 2.63 2.63 2.63 --- 1.97 7.89 10.04 0.44 2.05 2.70 1.9 9.0 11.9 99 3.85 A

2.0+2.0+2.5 2.54 2.54 3.17 --- 2.06 8.25 10.12 0.45 2.18 2.74 2.0 9.6 12.0 99 3.78 A

2.0+2.0+3.5 2.29 2.29 4.02 --- 2.26 8.60 10.22 0.47 2.34 2.88 2.1 10.3 12.6 99 3.68 A

2.0+2.0+4.2 2.10 2.10 4.40 --- 2.26 8.60 10.22 0.47 2.34 2.88 2.1 10.3 12.6 99 3.68 A

2.0+2.0+5.0 1.91 1.91 4.78 --- 2.66 8.60 10.40 0.58 2.34 2.96 2.5 10.3 13.0 99 3.68 A

2.0+2.0+6.0 1.72 1.72 5.16 --- 2.87 8.60 10.53 0.58 2.12 2.67 2.5 9.3 11.7 99 4.06 A

2.0+2.5+2.5 2.46 3.07 3.07 --- 2.16 8.60 10.13 0.46 2.35 2.84 2.0 10.3 12.5 99 3.66 A

2.0+2.5+3.5 2.15 2.69 3.76 --- 2.35 8.60 10.22 0.49 2.34 2.88 2.2 10.3 12.6 99 3.68 A

2.0+2.5+4.2 1.98 2.47 4.15 --- 2.36 8.60 10.23 0.49 2.34 2.87 2.2 10.3 12.6 99 3.68 A

2.0+2.5+5.0 1.81 2.26 4.53 --- 2.75 8.60 10.63 0.60 2.32 2.99 2.6 10.2 13.1 99 3.71 A

2.0+2.5+6.0 1.64 2.05 4.91 --- 2.96 8.60 10.64 0.60 2.10 2.64 2.6 9.2 11.6 99 4.10 A

2.0+3.5+3.5 1.92 3.34 3.34 --- 2.64 8.60 10.35 0.55 2.31 2.93 2.4 10.1 12.9 99 3.72 A

2.0+3.5+4.2 1.77 3.10 3.72 --- 2.64 8.60 10.35 0.55 2.31 2.92 2.4 10.1 12.8 99 3.72 A

2.0+3.5+5.0 1.64 2.87 4.09 --- 2.94 8.60 10.68 0.62 2.29 3.06 2.7 10.1 13.4 99 3.76 A

2.0+4.2+4.2 1.65 3.47 3.47 --- 2.64 8.60 10.36 0.55 2.31 2.92 2.4 10.1 12.8 99 3.72 A

2.5+2.5+2.5 2.86 2.86 2.86 --- 2.26 8.58 10.24 0.48 2.35 2.87 2.1 10.3 12.6 99 3.65 A

2.5+2.5+3.5 2.53 2.53 3.54 --- 2.45 8.60 10.45 0.51 2.34 2.96 2.2 10.3 13.0 99 3.68 A

2.5+2.5+4.2 2.34 2.34 3.93 --- 2.45 8.60 10.46 0.51 2.34 2.96 2.2 10.3 13.0 99 3.68 A

2.5+2.5+5.0 2.15 2.15 4.30 --- 2.85 8.60 10.64 0.62 2.29 3.02 2.7 10.1 13.3 99 3.76 A

2.5+2.5+6.0 1.95 1.95 4.70 --- 3.06 8.60 10.65 0.62 2.08 2.64 2.7 9.1 11.6 99 4.13 A

2.5+3.5+3.5 2.26 3.17 3.17 --- 2.73 8.60 10.58 0.56 2.31 2.96 2.5 10.1 13.0 99 3.72 A

2.5+3.5+4.2 2.11 2.95 3.54 --- 2.74 8.60 10.59 0.56 2.31 2.95 2.5 10.1 13.0 99 3.72 A

2.5+3.5+5.0 1.95 2.74 3.91 --- 3.13 8.60 10.65 0.64 2.29 2.98 2.8 10.1 13.1 99 3.76 A

2.5+4.2+4.2 1.97 3.31 3.31 --- 2.74 8.60 10.59 0.56 2.31 2.95 2.5 10.1 13.0 99 3.72 A

3.5+3.5+3.5 2.86 2.86 2.86 --- 2.92 8.58 10.63 0.61 2.29 3.03 2.7 10.1 13.3 99 3.75 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

100

4MXS-F

GC_pre2_lowres.pdf 100 30/11/2011 12:31:07

Page 103: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS68F2V1B

1.5+1.5+1.5+1.5 1.94 1.94 1.94 1.94 2.42 7.76 9.68 0.52 1.62 2.30 2.3 7.1 10.1 99 4.79 A

1.5+1.5+1.5+2.0 1.89 1.89 1.89 2.52 2.42 8.18 9.86 0.52 1.78 2.38 2.3 7.8 10.5 99 4.60 A

1.5+1.5+1.5+2.5 1.84 1.84 1.84 3.07 2.52 8.60 9.96 0.53 1.94 2.34 2.3 8.5 10.3 99 4.43 A

1.5+1.5+1.5+3.5 1.61 1.61 1.61 3.76 2.72 8.60 10.06 0.57 1.94 2.40 2.5 8.5 10.5 99 4.43 A

1.5+1.5+1.5+4.2 1.48 1.48 1.48 4.15 2.73 8.60 10.06 0.56 1.93 2.39 2.5 8.5 10.5 99 4.46 A

1.5+1.5+1.5+5.0 1.36 1.36 1.36 4.53 3.04 8.60 10.12 0.63 1.89 2.31 2.8 8.3 10.1 99 4.55 A

1.5+1.5+1.5+6.0 1.23 1.23 1.23 4.91 2.98 8.60 10.46 0.48 1.66 2.15 2.1 7.3 9.4 99 5.18 A

1.5+1.5+2.0+2.0 1.84 1.84 2.46 2.46 2.42 8.60 10.04 0.52 1.94 2.46 2.3 8.5 10.8 99 4.43 A

1.5+1.5+2.0+2.5 1.72 1.72 2.29 2.87 2.52 8.60 10.13 0.53 1.94 2.42 2.3 8.5 10.6 99 4.43 A

1.5+1.5+2.0+3.5 1.52 1.52 2.02 3.54 2.72 8.60 10.23 0.57 1.94 2.47 2.5 8.5 10.8 99 4.43 A

1.5+1.5+2.0+4.2 1.40 1.40 1.87 3.93 2.73 8.60 10.24 0.56 1.93 2.47 2.5 8.5 10.8 99 4.46 A

1.5+1.5+2.0+5.0 1.29 1.29 1.72 4.30 3.04 8.60 10.30 0.63 1.89 2.39 2.8 8.3 10.5 99 4.55 A

1.5+1.5+2.0+6.0 1.17 1.17 1.56 4.69 2.98 8.60 10.64 0.48 1.66 2.22 2.1 7.3 9.7 99 5.18 A

1.5+1.5+2.5+2.5 1.61 1.61 2.69 2.69 2.62 8.60 10.14 0.55 1.94 2.42 8.5 2.4 10.6 99 4.43 A

1.5+1.5+2.5+3.5 1.43 1.43 2.39 3.34 2.92 8.60 10.24 0.63 1.94 2.47 8.5 2.8 10.8 99 4.43 A

1.5+1.5+2.5+4.2 1.33 1.33 2.22 3.72 2.92 8.60 10.24 0.62 1.93 2.47 8.5 2.7 10.8 99 4.46 A

1.5+1.5+2.5+5.0 1.23 1.23 2.05 4.10 3.04 8.60 10.48 0.63 1.89 2.46 8.3 2.8 10.8 99 4.55 A

1.5+1.5+3.5+3.5 1.29 1.29 3.01 3.01 3.12 8.60 10.34 0.68 1.93 2.50 8.5 3.0 11.0 99 4.46 A

1.5+1.5+3.5+4.2 1.21 1.21 2.81 3.38 2.93 8.60 10.43 0.62 1.89 2.54 8.3 2.7 11.2 99 4.55 A

1.5+2.0+2.0+2.0 1.72 2.29 2.29 2.29 2.42 8.60 10.22 0.52 1.94 2.54 8.5 2.3 11.2 99 4.43 A

1.5+2.0+2.0+2.5 1.61 2.15 2.15 2.69 2.52 8.60 10.31 0.53 1.94 2.49 8.5 2.3 10.9 99 4.43 A

1.5+2.0+2.0+3.5 1.43 1.91 1.91 3.34 2.72 8.60 10.41 0.57 1.94 2.55 8.5 2.5 11.2 99 4.43 A

1.5+2.0+2.0+4.2 1.33 1.77 1.77 3.72 2.73 8.60 10.42 0.56 1.93 2.55 8.5 2.5 11.2 99 4.46 A

1.5+2.0+2.0+5.0 1.23 1.64 1.64 4.10 3.04 8.60 10.48 0.63 1.89 2.46 8.3 2.8 10.8 99 4.55 A

1.5+2.0+2.5+2.5 1.52 2.02 2.53 2.53 2.62 8.60 10.31 0.55 1.94 2.49 8.5 2.4 10.9 99 4.43 A

1.5+2.0+2.5+3.5 1.36 1.81 2.26 3.17 2.92 8.60 10.41 0.63 1.94 2.55 8.5 2.8 11.2 99 4.43 A

1.5+2.0+2.5+4.2 1.26 1.69 2.11 3.54 2.92 8.60 10.42 0.62 1.93 2.55 8.5 2.7 11.2 99 4.46 A

1.5+2.0+2.5+5.0 1.17 1.56 1.95 3.91 3.04 8.60 10.66 0.63 1.89 2.54 8.3 2.8 11.2 99 4.55 A

1.5+2.0+3.5+3.5 1.23 1.64 2.87 2.87 3.12 8.60 10.51 0.68 1.93 2.58 8.5 3.0 11.3 99 4.46 A

1.5+2.5+2.5+2.5 1.43 2.39 2.39 2.39 2.72 8.60 10.32 0.58 1.94 2.49 8.5 2.5 10.9 99 4.43 A

1.5+2.5+2.5+3.5 1.29 2.15 2.15 3.01 3.02 8.60 10.50 0.66 1.93 2.59 8.5 2.9 11.4 99 4.46 A

1.5+2.5+2.5+4.2 1.21 2.01 2.01 3.38 2.92 8.60 10.59 0.62 1.93 2.62 8.5 2.7 11.5 99 4.46 A

1.5+2.5+3.5+3.5 1.17 1.95 2.74 2.74 3.12 8.60 10.60 0.68 1.90 2.62 8.3 3.0 11.5 99 4.53 A

2.0+2.0+2.0+2.0 2.15 2.15 2.15 2.15 2.42 8.60 10.39 0.52 1.91 2.61 8.4 2.3 11.5 99 4.50 A

2.0+2.0+2.0+2.5 2.02 2.02 2.02 2.54 2.52 8.60 10.48 0.53 1.91 2.57 8.4 2.3 11.3 99 4.50 A

2.0+2.0+2.0+3.5 1.81 1.81 1.81 3.17 2.72 8.60 10.58 0.57 1.90 2.63 8.3 2.5 11.6 99 4.53 A

2.0+2.0+2.0+4.2 1.69 1.69 1.69 3.54 2.73 8.60 10.59 0.56 1.90 2.63 8.3 2.5 11.6 99 4.53 A

2.0+2.0+2.0+5.0 1.56 1.56 1.56 3.92 3.04 8.60 10.65 0.63 1.86 2.54 8.2 2.8 11.2 99 4.62 A

2.0+2.0+2.5+2.5 1.91 1.91 2.39 2.39 2.62 8.60 10.49 0.55 1.91 2.57 8.4 2.4 11.3 99 4.50 A

2.0+2.0+2.5+3.5 1.72 1.72 2.15 3.01 2.92 8.60 10.59 0.60 1.90 2.63 8.3 2.6 11.6 99 4.53 A

2.0+2.0+2.5+4.2 1.61 1.61 2.01 3.38 2.92 8.60 10.59 0.60 1.90 2.63 8.3 2.6 11.6 99 4.53 A

2.0+2.0+3.5+3.5 1.56 1.56 2.74 2.74 3.12 8.60 10.69 0.65 1.90 2.66 8.3 2.9 11.7 99 4.53 A

2.0+2.5+2.5+2.5 1.82 2.26 2.26 2.26 2.72 8.60 10.49 0.57 1.91 2.57 8.4 2.5 11.3 99 4.50 A

2.0+2.5+2.5+3.5 1.64 2.05 2.05 2.86 3.02 8.60 10.68 0.63 1.90 2.67 8.3 2.8 11.7 99 4.53 A

2.5+2.5+2.5+2.5 2.15 2.15 2.15 2.15 2.82 8.60 10.67 0.57 1.91 2.59 8.4 2.5 11.4 99 4.50 A

2.5+2.5+2.5+3.5 1.95 1.95 1.95 2.75 3.12 8.60 10.68 0.64 1.88 2.58 8.3 2.8 11.3 99 4.57 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 11.0kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0 kW class; wall mounted G series

* This page contains preliminary data

101

4MXS-F

GC_pre2_lowres.pdf 101 30/11/2011 12:31:07

Page 104: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

1.5 1.50 --- --- --- 1.42 1.50 2.35 0.43 0.48 0.74 1.9 2.1 3.3 98 3.13 B 240

2.0 2.00 --- --- --- 1.43 2.00 2.99 0.43 0.61 1.10 1.9 2.7 4.9 98 3.28 A 305

2.5 2.50 --- --- --- 1.45 2.50 3.52 0.47 0.78 1.33 2.1 3.5 5.9 98 3.21 A 390

3.5 3.50 --- --- --- 1.49 3.50 4.80 0.47 1.19 1.82 2.1 5.3 8.1 98 2.94 C 595

4.2 4.20 --- --- --- 1.99 4.20 5.17 0.53 1.52 1.92 2.4 6.7 8.5 98 2.76 D 760

5.0 5.00 --- --- --- 2.07 5.00 5.70 0.49 1.82 2.08 2.2 8.1 9.2 98 2.75 D 910

6.0 6.00 --- --- --- 2.17 6.00 6.60 0.50 1.99 2.38 2.2 8.8 10.6 98 3.02 B 995

7.1 7.10 --- --- --- 2.28 7.10 7.37 0.50 2.69 2.88 2.2 11.9 12.8 98 2.64 D 1345

1.5+1.5 1.50 1.50 --- --- 1.89 3.00 4.03 0.46 0.83 1.09 2.0 3.7 4.8 98 3.61 A 415

1.5+2.0 1.50 2.00 --- --- 1.91 3.50 4.51 0.50 1.00 1.28 2.2 4.4 5.7 98 3.50 A 500

1.5+2.5 1.50 2.50 --- --- 1.97 4.00 4.97 0.46 1.14 1.38 2.0 5.1 6.1 98 3.51 A 570

1.5+3.5 1.50 3.50 --- --- 2.07 5.00 5.83 0.46 1.52 1.82 2.0 6.7 8.1 98 3.29 A 760

1.5+4.2 1.50 4.20 --- --- 2.14 5.70 6.38 0.50 1.88 2.10 2.2 8.3 9.3 98 3.03 B 940

1.5+5.0 1.50 5.00 --- --- 2.22 6.50 6.95 0.51 2.22 2.51 2.3 9.8 11.1 98 2.93 C 1110

1.5+6.0 1.44 5.75 --- --- 2.34 7.19 7.59 0.55 2.42 2.67 2.4 10.7 11.8 98 2.97 C 1210

1.5+7.1 1.30 6.15 --- --- 2.49 7.45 8.19 0.59 2.61 3.08 2.6 11.6 13.7 98 2.85 C 1305

2.0+2.0 2.00 2.00 --- --- 1.97 4.00 5.30 0.50 1.23 1.67 2.2 5.5 7.4 98 3.25 A 615

2.0+2.5 2.00 2.50 --- --- 2.02 4.50 5.73 0.50 1.38 1.77 2.2 6.1 7.9 98 3.26 A 690

2.0+3.5 2.00 3.50 --- --- 2.12 5.50 6.31 0.50 1.77 2.44 2.2 7.9 10.8 98 3.11 B 885

2.0+4.2 2.00 4.20 --- --- 2.19 6.20 6.77 0.50 2.21 2.56 2.2 9.8 11.4 98 2.81 C 1105

2.0+5.0 2.00 5.00 --- --- 2.27 7.00 7.30 0.51 2.51 2.76 2.3 11.1 12.2 98 2.79 D 1255

2.0+6.0 1.83 5.48 --- --- 2.41 7.31 7.90 0.55 2.48 2.87 2.4 11.0 12.7 98 2.95 C 1240

2.0+7.1 1.66 5.90 --- --- 2.56 7.56 8.45 0.59 2.67 3.29 2.6 11.8 14.6 98 2.83 C 1335

2.5+2.5 2.50 2.50 --- --- 2.07 5.00 6.12 0.46 1.47 2.44 2.0 6.5 10.8 98 3.40 A 735

2.5+3.5 2.50 3.50 --- --- 2.17 6.00 6.60 0.50 1.99 2.38 2.2 8.8 10.6 98 3.02 B 995

2.5+4.2 2.50 4.20 --- --- 2.24 6.70 7.11 0.50 2.44 2.63 2.2 10.8 11.7 98 2.75 D 1220

2.5+5.0 2.40 4.79 --- --- 2.34 7.19 7.59 0.54 2.64 2.96 2.4 11.7 13.1 98 2.72 D 1320

2.5+6.0 2.18 5.24 --- --- 2.48 7.42 8.16 0.59 2.60 3.07 2.6 11.5 13.6 98 2.85 C 1300

2.5+7.1 2.00 5.68 --- --- 2.63 7.68 8.66 0.59 2.74 3.43 2.6 12.2 15.2 98 2.80 C 1370

3.5+3.5 3.50 3.50 --- --- 2.27 7.00 7.30 0.50 2.63 2.88 2.2 11.7 12.8 98 2.66 D 1315

3.5+4.2 3.29 3.95 --- --- 2.37 7.24 7.73 0.54 2.82 3.08 2.4 12.5 13.7 98 2.57 E 1410

3.5+5.0 3.06 4.36 --- --- 2.48 7.42 8.16 0.58 2.83 3.37 2.6 12.6 15.0 98 2.62 D 1415

3.5+6.0 2.82 4.83 --- --- 2.61 7.65 8.62 0.59 2.74 4.11 2.6 12.2 18.2 98 2.79 D 1370

3.5+7.1 2.61 5.30 --- --- 2.77 7.91 8.31 0.63 2.87 3.15 2.8 12.7 14.0 98 2.76 D 1435

4.2+4.2 3.70 3.70 --- --- 2.46 7.40 8.11 0.58 2.88 3.42 2.6 12.8 15.2 98 2.57 E 1440

4.2+5.0 3.46 4.12 --- --- 2.57 7.58 8.48 0.58 2.96 3.59 2.6 13.1 15.9 98 2.56 E 1480

4.2+6.0 3.22 4.60 --- --- 2.71 7.82 8.89 0.63 2.80 3.66 2.8 12.4 16.2 98 2.79 D 1400

4.2+7.1 2.97 5.03 --- --- 2.86 8.00 9.16 0.67 2.94 3.82 3.0 13.0 16.9 98 2.72 D 1470

5.0+5.0 3.88 3.88 --- --- 2.68 7.76 8.66 0.62 2.98 3.62 2.8 13.2 16.1 98 2.60 D 1490

5.0+6.0 3.64 4.36 --- --- 2.82 8.00 9.14 0.67 2.88 3.69 3.0 12.8 16.4 98 2.78 D 1440

5.0+7.1 3.31 4.69 --- --- 2.97 8.00 9.35 0.67 2.82 3.85 3.0 12.5 17.1 98 2.84 C 1410

6.0+6.0 4.00 4.00 --- --- 2.96 8.00 9.39 0.67 2.65 3.60 3.0 11.8 16.0 98 3.02 B 1325

6.0+7.1 3.66 4.34 --- --- 3.11 8.00 9.55 0.71 2.58 3.76 3.1 11.4 16.7 98 3.10 B 1290

7.1+7.1 4.00 4.00 --- --- 3.26 8.00 9.60 0.75 2.51 3.77 3.3 11.1 16.7 98 3.19 B 1255

1.5+1.5+1.5 1.50 1.50 1.50 --- 2.02 4.50 5.41 0.48 1.14 1.47 2.1 5.1 6.5 98 3.95 A 570

1.5+1.5+2.0 1.50 1.50 2.00 --- 2.07 5.00 5.83 0.52 1.28 1.67 2.3 5.7 7.4 98 3.91 A 640

1.5+1.5+2.5 1.50 1.50 2.50 --- 2.12 5.50 6.23 0.52 1.52 1.89 2.3 6.7 8.4 98 3.62 A 760

1.5+1.5+3.5 1.50 1.50 3.50 --- 2.22 6.50 6.95 0.52 2.00 2.29 2.3 8.9 10.2 98 3.25 A 1000

1.5+1.5+4.2 1.48 1.48 4.15 --- 2.30 7.12 7.41 0.52 2.35 2.54 2.3 10.4 11.3 98 3.03 B 1175

1.5+1.5+5.0 1.37 1.37 4.57 --- 2.41 7.31 7.88 0.56 2.43 2.75 2.5 10.8 12.2 98 3.01 B 1215

1.5+1.5+6.0 1.26 1.26 5.03 --- 2.55 7.54 8.38 0.60 2.32 2.85 2.7 10.3 12.6 98 3.25 A 1160

1.5+1.5+7.1 1.16 1.16 5.48 --- 2.70 7.79 8.84 0.64 2.45 3.14 2.8 10.9 13.9 98 3.18 B 1225

1.5+2.0+2.0 1.50 2.00 2.00 --- 2.12 5.50 6.23 0.52 1.52 1.89 2.3 6.7 8.4 98 3.62 A 760

1.5+2.0+2.5 1.50 2.00 2.50 --- 2.17 6.00 6.60 0.52 1.73 2.06 2.3 7.7 9.1 98 3.47 A 865

1.5+2.0+3.5 1.50 2.00 3.50 --- 2.27 7.00 7.28 0.52 2.29 2.48 2.3 10.2 11.0 98 3.06 B 1145

1.5+2.0+4.2 1.41 1.88 3.95 --- 2.37 7.24 7.71 0.55 2.42 2.74 2.4 10.7 12.2 98 2.99 C 1210

1.5+2.0+5.0 1.31 1.75 4.36 --- 2.48 7.42 8.14 0.59 2.49 2.95 2.6 11.0 13.1 98 2.98 C 1245

1.5+2.0+6.0 1.21 1.61 4.83 --- 2.61 7.65 8.60 0.60 2.38 3.00 2.7 10.6 13.3 98 3.21 A 1190

1.5+2.0+7.1 1.12 1.49 5.30 --- 2.77 7.91 9.01 0.64 2.51 3.29 2.8 11.1 14.6 98 3.15 B 1255

1.5+2.5+2.5 1.50 2.50 2.50 --- 2.22 6.50 6.95 0.52 2.00 2.29 2.3 8.9 10.2 98 3.25 A 1000

1.5+2.5+3.5 1.44 2.40 3.36 --- 2.34 7.19 7.59 0.55 2.42 2.67 2.4 10.7 11.8 98 2.97 C 1210

1.5+2.5+4.2 1.34 2.24 3.76 --- 2.44 7.35 7.99 0.55 2.54 2.94 2.4 11.3 13.0 98 2.89 C 1270

1.5+2.5+5.0 1.26 2.09 4.19 --- 2.55 7.54 8.38 0.59 2.55 3.10 2.6 11.3 13.8 98 2.96 C 1275

1.5+2.5+6.0 1.17 1.94 4.66 --- 2.68 7.77 8.80 0.60 2.45 3.14 2.7 10.9 13.9 98 3.17 B 1225

1.5+2.5+7.1 1.08 1.80 5.12 --- 2.83 8.00 9.16 0.64 2.58 3.37 2.8 11.4 15.0 98 3.10 B 1290

1.5+3.5+3.5 1.31 3.06 3.06 --- 2.48 7.42 8.14 0.59 2.54 3.08 2.6 11.3 13.7 98 2.92 C 1270

1.5+3.5+4.2 1.24 2.88 3.46 --- 2.57 7.58 8.47 0.59 2.67 3.29 2.6 11.8 14.6 98 2.84 C 1335

1.5+3.5+5.0 1.17 2.72 3.89 --- 2.68 7.77 8.80 0.63 2.68 3.46 2.8 11.9 15.4 98 2.90 C 1340

1.5+3.5+6.0 1.09 2.55 4.36 --- 2.82 8.00 9.13 0.64 2.58 3.37 2.8 11.4 15.0 98 3.10 B 1290

1.5+3.5+7.1 0.99 2.31 4.69 --- 2.97 8.00 9.39 0.67 2.51 3.61 3.0 11.1 16.0 98 3.19 B 1255

1.5+4.2+4.2 1.17 3.29 3.29 --- 2.67 7.75 8.76 0.63 2.67 3.51 2.8 11.8 15.6 98 2.90 C 1335

1.5+4.2+5.0 1.11 3.11 3.71 --- 2.78 7.93 9.04 0.63 2.68 3.61 2.8 11.9 16.0 98 2.96 C 1340

1.5+4.2+6.0 1.03 2.87 4.10 --- 2.92 8.00 9.30 0.67 2.51 3.53 3.0 11.1 15.7 98 3.19 B 1255

1.5+4.2+7.1 0.94 2.63 4.44 --- 3.07 8.00 9.50 0.71 2.52 3.69 3.1 11.2 16.4 98 3.17 B 1260

1.5+5.0+5.0 1.04 3.48 3.48 --- 2.89 8.00 9.26 0.67 2.76 3.72 3.0 12.2 16.5 98 2.90 C 1380

1.5+5.0+6.0 0.96 3.20 3.84 --- 3.03 8.00 9.45 0.68 2.46 3.55 3.0 10.9 15.7 98 3.25 A 1230

1.5+5.0+7.1 0.88 2.94 4.18 --- 3.18 8.00 9.57 0.71 2.39 3.63 3.1 10.6 16.1 98 3.35 A 1195

1.5+6.0+6.0 0.89 3.56 3.56 --- 3.16 8.00 9.56 0.72 2.28 3.29 3.2 10.1 14.6 98 3.51 A 1140

2.0+2.0+2.0 2.00 2.00 2.00 --- 2.17 6.00 6.63 0.52 1.73 2.12 2.3 7.7 9.4 98 3.47 A 865

2.0+2.0+2.5 2.00 2.00 2.50 --- 2.22 6.50 6.95 0.52 2.00 2.29 2.3 8.9 10.2 98 3.25 A 1000

2.0+2.0+3.5 1.92 1.92 3.36 --- 2.34 7.19 7.61 0.55 2.42 2.67 2.4 10.7 11.8 98 2.97 C 1210

2.0+2.0+4.2 1.79 1.79 3.76 --- 2.44 7.35 8.01 0.55 2.54 2.87 2.4 11.3 12.7 98 2.89 C 1270

2.0+2.0+5.0 1.68 1.68 4.19 --- 2.55 7.54 8.40 0.59 2.55 3.17 2.6 11.3 14.1 98 2.96 C 1275

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

102

4MXS-E

GC_pre2_lowres.pdf 102 30/11/2011 12:31:08

Page 105: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

2.0+2.0+6.0 1.55 1.55 4.66 --- 7.77 2.68 8.82 2.45 0.60 3.14 10.9 2.7 13.9 98 3.17 B 1225

2.0+2.0+7.1 1.44 1.44 5.12 --- 8.00 2.83 9.18 2.58 0.64 3.45 11.4 2.8 15.3 98 3.10 B 1290

2.0+2.5+2.5 2.00 2.50 2.50 --- 7.00 2.27 7.30 2.29 0.52 2.48 10.2 2.3 11.0 98 3.06 B 1145

2.0+2.5+3.5 1.83 2.28 3.20 --- 7.31 2.41 7.90 2.48 0.55 2.87 11.0 2.4 12.7 98 2.95 C 1240

2.0+2.5+4.2 1.72 2.15 3.61 --- 7.47 2.50 8.26 2.61 0.59 3.01 11.6 2.6 13.4 98 2.86 C 1305

2.0+2.5+5.0 1.61 2.01 4.03 --- 7.65 2.61 8.62 2.62 0.59 3.31 11.6 2.6 14.7 98 2.92 C 1310

2.0+2.5+6.0 1.50 1.88 4.50 --- 7.88 2.75 8.99 2.51 0.64 3.29 11.1 2.8 14.6 98 3.14 B 1255

2.0+2.5+7.1 1.38 1.72 4.90 --- 8.00 2.90 9.30 2.58 0.67 3.53 11.4 3.0 15.7 98 3.10 B 1290

2.0+3.5+3.5 1.68 2.93 2.93 --- 7.54 2.55 8.40 2.67 0.59 3.22 11.8 2.6 14.3 98 2.82 C 1335

2.0+3.5+4.2 1.59 2.78 3.33 --- 7.70 2.64 8.70 2.74 0.63 3.37 12.2 2.8 15.0 98 2.81 C 1370

2.0+3.5+5.0 1.50 2.63 3.75 --- 7.88 2.75 8.99 2.75 0.63 3.61 12.2 2.8 16.0 98 2.87 C 1375

2.0+3.5+6.0 1.39 2.43 4.17 --- 8.00 2.89 9.28 2.58 0.67 3.52 11.4 3.0 15.6 98 3.10 B 1290

2.0+3.5+7.1 1.27 2.22 4.51 --- 8.00 3.04 9.10 2.51 0.67 3.30 11.1 3.0 14.6 98 3.19 B 1255

2.0+4.2+4.2 1.51 3.17 3.17 --- 7.86 2.74 8.99 2.74 0.63 3.66 12.2 2.8 16.2 98 2.87 C 1370

2.0+4.2+5.0 1.43 3.00 3.57 --- 8.00 2.85 9.23 2.75 0.67 3.77 12.2 3.0 16.7 98 2.91 C 1375

2.0+4.2+6.0 1.31 2.75 3.93 --- 8.00 2.98 9.45 2.51 0.67 3.60 11.1 3.0 16.0 98 3.19 B 1255

2.0+4.2+7.1 1.20 2.53 4.27 --- 8.00 3.14 9.60 2.52 0.71 3.69 11.2 3.1 16.4 98 3.17 B 1260

2.0+5.0+5.0 1.33 3.33 3.33 --- 8.00 2.96 9.39 2.76 0.67 3.80 12.2 3.0 16.9 98 2.90 C 1380

2.0+5.0+6.0 1.23 3.08 3.69 --- 8.00 3.09 9.54 2.46 0.71 3.63 10.9 3.1 16.1 98 3.25 A 1230

2.0+5.0+7.1 1.13 2.84 4.03 --- 8.00 3.25 9.60 2.39 0.71 3.63 10.6 3.1 16.1 98 3.35 A 1195

2.0+6.0+6.0 1.14 3.43 3.43 --- 8.00 3.23 9.60 2.28 0.72 3.37 10.1 3.2 15.0 98 3.51 A 1140

2.5+2.5+2.5 2.40 2.40 2.40 --- 7.20 2.34 7.61 2.42 0.55 2.67 10.7 2.4 11.8 98 2.98 C 1210

2.5+2.5+3.5 2.18 2.18 3.06 --- 7.42 2.48 8.16 2.54 0.59 3.08 11.3 2.6 13.7 98 2.92 C 1270

2.5+2.5+4.2 2.06 2.06 3.46 --- 7.58 2.57 8.49 2.67 0.59 3.29 11.8 2.6 14.6 98 2.84 C 1335

2.5+2.5+5.0 1.94 1.94 3.89 --- 7.77 2.68 8.82 2.68 0.63 3.46 11.9 2.8 15.4 98 2.90 C 1340

2.5+2.5+6.0 1.82 1.82 4.36 --- 8.00 2.82 9.15 2.58 0.64 3.45 11.4 2.8 15.3 98 3.10 B 1290

2.5+2.5+7.1 1.65 1.65 4.69 --- 8.00 2.97 9.41 2.51 0.67 3.61 11.1 3.0 16.0 98 3.19 B 1255

2.5+3.5+3.5 2.01 2.82 2.82 --- 7.65 2.61 8.34 2.74 0.59 3.01 12.2 2.6 13.4 98 2.79 D 1370

2.5+3.5+4.2 1.92 2.68 3.22 --- 7.82 2.71 8.89 2.80 0.63 3.44 12.4 2.8 15.3 98 2.79 D 1400

2.5+3.5+5.0 1.82 2.55 3.64 --- 8.00 2.82 9.15 2.82 0.67 3.69 12.5 3.0 16.4 98 2.84 C 1410

2.5+3.5+6.0 1.67 2.33 4.00 --- 8.00 2.96 9.39 2.58 0.67 3.60 11.4 3.0 16.0 98 3.10 B 1290

2.5+3.5+7.1 1.53 2.14 4.34 --- 8.00 3.11 9.10 2.51 0.71 3.30 11.1 3.1 14.6 98 3.19 B 1255

2.5+4.2+4.2 1.83 3.07 3.07 --- 7.98 2.81 9.02 2.87 0.67 3.67 12.7 3.0 16.3 98 2.78 D 1435

2.5+4.2+5.0 1.71 2.87 3.42 --- 8.00 2.92 9.35 2.82 0.67 3.85 12.5 3.0 17.1 98 2.84 C 1410

2.5+4.2+6.0 1.57 2.65 3.78 --- 8.00 3.05 9.53 2.58 0.67 3.68 11.4 3.0 16.3 98 3.10 B 1290

2.5+4.2+7.1 1.45 2.43 4.12 --- 8.00 3.20 9.63 2.52 0.71 3.77 11.2 3.1 16.7 98 3.17 B 1260

2.5+5.0+5.0 1.60 3.20 3.20 --- 8.00 3.03 9.47 2.76 0.71 3.88 12.2 3.1 17.2 98 2.90 C 1380

2.5+5.0+6.0 1.48 2.96 3.56 --- 8.00 3.16 9.58 2.46 0.71 3.63 10.9 3.1 16.1 98 3.25 A 1230

2.5+6.0+6.0 1.38 3.31 3.31 --- 8.00 3.30 9.60 2.22 0.72 3.37 9.8 3.2 15.0 98 3.60 A 1110

3.5+3.5+3.5 2.63 2.63 2.63 --- 7.89 2.75 8.67 2.87 0.63 3.15 12.7 2.8 14.0 98 2.75 D 1435

3.5+3.5+4.2 2.50 2.50 3.00 --- 8.01 2.85 9.29 2.94 0.67 3.66 13.0 3.0 16.2 98 2.72 D 1470

3.5+3.5+5.0 2.33 2.33 3.33 --- 8.00 2.96 9.35 2.82 0.67 3.85 12.5 3.0 17.1 98 2.84 C 1410

3.5+3.5+6.0 2.15 2.15 3.69 --- 8.00 3.09 9.11 2.58 0.71 3.37 11.4 3.1 15.0 98 3.10 B 1290

3.5+3.5+7.1 1.99 1.99 4.03 --- 8.00 3.25 9.60 2.52 0.75 3.77 11.2 3.3 16.7 98 3.17 B 1260

3.5+4.2+4.2 2.35 2.82 2.82 --- 8.00 2.94 9.18 2.87 0.67 3.82 12.7 3.0 16.9 98 2.79 D 1435

3.5+4.2+5.0 2.20 2.65 3.15 --- 8.00 3.05 9.36 2.75 0.71 3.85 12.2 3.1 17.1 98 2.91 C 1375

3.5+4.2+6.0 2.04 2.45 3.50 --- 8.00 3.19 9.59 2.51 0.71 3.77 11.1 3.1 16.7 98 3.19 B 1255

3.5+5.0+5.0 2.07 2.96 2.96 --- 8.00 3.16 9.55 2.76 0.71 3.88 12.2 3.1 17.2 98 2.90 C 1380

3.5+5.0+6.0 1.93 2.76 3.31 --- 8.00 3.30 9.60 2.46 0.75 3.63 10.9 3.3 16.1 98 3.25 A 1230

4.2+4.2+4.2 2.67 2.67 2.67 --- 8.00 3.04 9.19 2.87 0.71 3.82 12.7 3.1 16.9 98 2.79 D 1435

4.2+4.2+5.0 2.51 2.51 2.99 --- 8.00 3.15 9.37 2.75 0.71 3.85 12.2 3.1 17.1 98 2.91 C 1375

4.2+4.2+6.0 2.33 2.33 3.33 --- 8.00 3.29 9.60 2.51 0.75 3.77 11.1 3.3 16.7 98 3.19 B 1255

4.2+5.0+5.0 2.37 2.82 2.82 --- 8.00 3.26 9.56 2.70 0.75 3.88 12.0 3.3 17.2 98 2.96 C 1350

1.5+1.5+1.5+1.5 1.50 1.50 1.50 1.50 6.00 2.17 6.60 1.47 0.53 1.73 6.5 2.4 7.7 98 4.08 A 735

1.5+1.5+1.5+2.0 1.50 1.50 1.50 2.00 6.50 2.22 6.95 1.68 0.53 1.90 7.5 2.4 8.4 98 3.87 A 840

1.5+1.5+1.5+2.5 1.50 1.50 1.50 2.50 7.00 2.27 7.28 1.90 0.53 2.07 8.4 2.4 9.2 98 3.68 A 950

1.5+1.5+1.5+3.5 1.37 1.37 1.37 3.20 7.31 2.41 7.88 2.07 0.56 2.38 9.2 2.5 10.6 98 3.53 A 1035

1.5+1.5+1.5+4.2 1.29 1.29 1.29 3.61 7.47 2.50 8.24 2.13 0.56 2.58 9.4 2.5 11.4 98 3.51 A 1065

1.5+1.5+1.5+5.0 1.21 1.21 1.21 4.03 7.65 2.61 8.60 2.33 0.60 2.87 10.3 2.7 12.7 98 3.28 A 1165

1.5+1.5+1.5+6.0 1.13 1.13 1.13 4.50 7.88 2.75 8.97 2.22 0.61 2.91 9.8 2.7 12.9 98 3.55 A 1110

1.5+1.5+1.5+7.1 1.03 1.03 1.03 4.90 8.00 2.90 9.28 2.22 0.64 3.06 9.8 2.8 13.6 98 3.60 A 1110

1.5+1.5+2.0+2.0 1.50 1.50 2.00 2.00 7.00 2.27 7.28 1.90 0.53 2.07 8.4 2.4 9.2 98 3.68 A 950

1.5+1.5+2.0+2.5 1.44 1.44 1.92 2.40 7.19 2.34 7.59 2.02 0.56 2.20 9.0 2.5 9.8 98 3.56 A 1010

1.5+1.5+2.0+3.5 1.31 1.31 1.75 3.06 7.42 2.48 8.14 2.13 0.56 2.51 9.4 2.5 11.1 98 3.48 A 1065

1.5+1.5+2.0+4.2 1.24 1.24 1.65 3.46 7.58 2.57 8.47 2.20 0.60 2.72 9.8 2.7 12.1 98 3.45 A 1100

1.5+1.5+2.0+5.0 1.17 1.17 1.55 3.89 7.77 2.68 8.80 2.39 0.60 3.01 10.6 2.7 13.4 98 3.25 A 1195

1.5+1.5+2.0+6.0 1.09 1.09 1.45 4.36 8.00 2.82 9.13 2.28 0.64 2.98 10.1 2.8 13.2 98 3.51 A 1140

1.5+1.5+2.0+7.1 0.99 0.99 1.32 4.69 8.00 2.97 9.39 2.22 0.68 3.14 9.8 3.0 13.9 98 3.60 A 1110

1.5+1.5+2.5+2.5 1.37 1.37 2.28 2.28 7.31 2.41 7.88 2.07 0.56 2.38 9.2 2.5 10.6 98 3.53 A 1035

1.5+1.5+2.5+3.5 1.26 1.26 2.09 2.93 7.54 2.55 8.38 2.32 0.60 2.86 10.3 2.7 12.7 98 3.25 A 1160

1.5+1.5+2.5+4.2 1.19 1.19 1.98 3.33 7.70 2.64 8.68 2.38 0.60 3.07 10.6 2.7 13.6 98 3.24 A 1190

1.5+1.5+2.5+5.0 1.13 1.13 1.88 3.75 7.88 2.75 8.97 2.46 0.64 3.16 10.9 2.8 14.0 98 3.20 A 1230

1.5+1.5+2.5+6.0 1.04 1.04 1.74 4.17 8.00 2.89 9.26 2.28 0.64 3.06 10.1 2.8 13.6 98 3.51 A 1140

1.5+1.5+2.5+7.1 0.95 0.95 1.59 4.51 8.00 3.04 9.47 2.22 0.68 3.21 9.8 3.0 14.2 98 3.60 A 1110

1.5+1.5+3.5+3.5 1.17 1.17 2.72 2.72 7.77 2.68 8.80 2.45 0.60 3.15 10.9 2.7 14.0 98 3.17 B 1225

1.5+1.5+3.5+4.2 1.11 1.11 2.59 3.11 7.93 2.78 9.04 2.52 0.64 3.30 11.2 2.8 14.6 98 3.15 B 1260

1.5+1.5+3.5+5.0 1.04 1.04 2.43 3.48 8.00 2.89 9.26 2.52 0.64 3.39 11.2 2.8 15.0 98 3.17 B 1260

1.5+1.5+3.5+6.0 0.96 0.96 2.24 3.84 8.00 3.03 9.45 2.28 0.68 3.21 10.1 3.0 14.2 98 3.51 A 1140

1.5+1.5+3.5+7.1 0.88 0.88 2.06 4.18 8.00 3.18 9.57 2.22 0.72 3.29 9.8 3.2 14.6 98 3.60 A 1110

1.5+1.5+4.2+4.2 1.05 1.05 2.95 2.95 8.00 2.87 9.23 2.58 0.64 3.45 11.4 2.8 15.3 98 3.10 B 1290

1.5+1.5+4.2+5.0 0.98 0.98 2.75 3.28 8.00 2.98 9.40 2.52 0.68 3.47 11.2 3.0 15.4 98 3.17 B 1260

1.5+1.5+4.2+6.0 0.91 0.91 2.55 3.64 8.00 3.12 9.54 2.28 0.68 3.29 10.1 3.0 14.6 98 3.51 A 1140

1.5+1.5+4.2+7.1 0.84 0.84 2.35 3.97 8.00 3.27 9.58 2.22 0.72 3.29 9.8 3.2 14.6 98 3.60 A 1110

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

103

4MXS-E

GC_pre2_lowres.pdf 103 30/11/2011 12:31:08

Page 106: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

1.5+1.5+5.0+5.0 0.92 0.92 3.08 3.08 8.00 3.09 9.52 2.40 0.68 3.42 10.6 3.0 15.2 98 3.33 A 1200

1.5+1.5+5.0+6.0 0.86 0.86 2.86 3.43 8.00 3.23 9.58 2.22 0.72 3.23 9.8 3.2 14.3 98 3.60 A 1110

1.5+2.0+2.0+2.0 1.44 1.92 1.92 1.92 7.19 2.34 7.59 2.02 0.56 2.20 9.0 2.5 9.8 98 3.56 A 1010

1.5+2.0+2.0+2.5 1.37 1.83 1.83 2.28 7.31 2.41 7.88 2.07 0.56 2.38 9.2 2.5 10.6 98 3.53 A 1035

1.5+2.0+2.0+3.5 1.26 1.68 1.68 2.93 7.54 2.55 8.38 2.20 0.60 2.65 9.8 2.7 11.8 98 3.43 A 1100

1.5+2.0+2.0+4.2 1.19 1.59 1.59 3.33 7.70 2.64 8.68 2.26 0.60 2.86 10.0 2.7 12.7 98 3.41 A 1130

1.5+2.0+2.0+5.0 1.13 1.50 1.50 3.75 7.88 2.75 8.97 2.46 0.64 3.16 10.9 2.8 14.0 98 3.20 A 1230

1.5+2.0+2.0+6.0 1.04 1.39 1.39 4.17 8.00 2.89 9.26 2.28 0.64 3.06 10.1 2.8 13.6 98 3.51 A 1140

1.5+2.0+2.0+7.1 0.95 1.27 1.27 4.51 8.00 3.04 9.47 2.22 0.68 3.21 9.8 3.0 14.2 98 3.60 A 1110

1.5+2.0+2.5+2.5 1.31 1.75 2.18 2.18 7.42 2.48 8.14 2.13 0.56 2.51 9.4 2.5 11.1 98 3.48 A 1065

1.5+2.0+2.5+3.5 1.21 1.61 2.01 2.82 7.65 2.61 8.60 2.38 0.60 3.00 10.6 2.7 13.3 98 3.21 A 1190

1.5+2.0+2.5+4.2 1.15 1.53 1.92 3.22 7.82 2.71 8.87 2.51 0.64 3.22 11.1 2.8 14.3 98 3.12 B 1255

1.5+2.0+2.5+5.0 1.09 1.45 1.82 3.64 8.00 2.82 9.13 2.52 0.64 3.24 11.2 2.8 14.4 98 3.17 B 1260

1.5+2.0+2.5+6.0 1.00 1.33 1.67 4.00 8.00 2.96 9.37 2.28 0.68 3.13 10.1 3.0 13.9 98 3.51 A 1140

1.5+2.0+2.5+7.1 0.92 1.22 1.53 4.34 8.00 3.11 9.53 2.22 0.68 3.29 9.8 3.0 14.6 98 3.60 A 1110

1.5+2.0+3.5+3.5 1.13 1.50 2.63 2.63 7.88 2.75 8.97 2.51 0.64 3.30 11.1 2.8 14.6 98 3.14 B 1255

1.5+2.0+3.5+4.2 1.07 1.43 2.50 3.00 8.00 2.85 9.18 2.58 0.64 3.45 11.4 2.8 15.3 98 3.10 B 1290

1.5+2.0+3.5+5.0 1.00 1.33 2.33 3.33 8.00 2.96 9.37 2.52 0.68 3.47 11.2 3.0 15.4 98 3.17 B 1260

1.5+2.0+3.5+6.0 0.92 1.23 2.15 3.69 8.00 3.09 9.52 2.28 0.68 3.29 10.1 3.0 14.6 98 3.51 A 1140

1.5+2.0+3.5+7.1 0.85 1.13 1.99 4.03 8.00 3.25 9.58 2.22 0.72 3.29 9.8 3.2 14.6 98 3.60 A 1110

1.5+2.0+4.2+4.2 1.01 1.34 2.82 2.82 8.00 2.94 9.35 2.58 0.67 3.53 11.4 3.0 15.7 98 3.10 B 1290

1.5+2.0+4.2+5.0 0.94 1.26 2.65 3.15 8.00 3.05 9.48 2.52 0.68 3.55 11.2 3.0 15.7 98 3.17 B 1260

1.5+2.0+4.2+6.0 0.88 1.17 2.45 3.50 8.00 3.19 9.57 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

1.5+2.0+5.0+5.0 0.89 1.19 2.96 2.96 8.00 3.16 9.56 2.40 0.71 3.50 10.6 3.1 15.5 98 3.33 A 1200

1.5+2.0+5.0+6.0 0.83 1.10 2.76 3.31 8.00 3.30 9.58 2.22 0.72 3.23 9.8 3.2 14.3 98 3.60 A 1110

1.5+2.5+2.5+2.5 1.26 2.09 2.09 2.09 7.54 2.55 8.38 2.20 0.60 2.65 9.8 2.7 11.8 98 3.43 A 1100

1.5+2.5+2.5+3.5 1.17 1.94 1.94 2.72 7.77 2.68 8.80 2.45 0.60 3.14 10.9 2.7 13.9 98 3.17 B 1225

1.5+2.5+2.5+4.2 1.11 1.85 1.85 3.11 7.93 2.78 9.04 2.58 0.64 3.30 11.4 2.8 14.6 98 3.07 B 1290

1.5+2.5+2.5+5.0 1.04 1.74 1.74 3.48 8.00 2.89 9.26 2.52 0.64 3.39 11.2 2.8 15.0 98 3.17 B 1260

1.5+2.5+2.5+6.0 0.96 1.60 1.60 3.84 8.00 3.03 9.45 2.28 0.68 3.21 10.1 3.0 14.2 98 3.51 A 1140

1.5+2.5+2.5+7.1 0.88 1.47 1.47 4.18 8.00 3.18 9.57 2.22 0.72 3.29 9.8 3.2 14.6 98 3.60 A 1110

1.5+2.5+3.5+3.5 1.09 1.82 2.55 2.55 8.00 2.82 9.13 2.58 0.64 3.37 11.4 2.8 15.0 98 3.10 B 1290

1.5+2.5+3.5+4.2 1.03 1.71 2.39 2.87 8.00 2.92 9.30 2.58 0.67 3.53 11.4 3.0 15.7 98 3.10 B 1290

1.5+2.5+3.5+5.0 0.96 1.60 2.24 3.20 8.00 3.03 9.45 2.52 0.68 3.47 11.2 3.0 15.4 98 3.17 B 1260

1.5+2.5+3.5+6.0 0.89 1.48 2.07 3.56 8.00 3.16 9.56 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

1.5+2.5+4.2+4.2 0.97 1.61 2.71 2.71 8.00 3.01 9.44 2.58 0.67 3.61 11.4 3.0 16.0 98 3.10 B 1290

1.5+2.5+4.2+5.0 0.91 1.52 2.55 3.03 8.00 3.12 9.54 2.52 0.71 3.55 11.2 3.1 15.7 98 3.17 B 1260

1.5+2.5+4.2+6.0 0.85 1.41 2.37 3.38 8.00 3.26 9.58 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

1.5+2.5+5.0+5.0 0.86 1.43 2.86 2.86 8.00 3.23 9.58 2.40 0.71 3.50 10.6 3.1 15.5 98 3.33 A 1200

1.5+3.5+3.5+3.5 1.00 2.33 2.33 2.33 8.00 2.96 9.37 2.58 0.67 3.45 11.4 3.0 15.3 98 3.10 B 1290

1.5+3.5+3.5+4.2 0.94 2.20 2.20 2.65 8.00 3.05 9.48 2.58 0.67 3.61 11.4 3.0 16.0 98 3.10 B 1290

1.5+3.5+3.5+5.0 0.89 2.07 2.07 2.96 8.00 3.16 9.56 2.52 0.71 3.55 11.2 3.1 15.7 98 3.17 B 1260

1.5+3.5+3.5+6.0 0.83 1.93 1.93 3.31 8.00 3.30 9.58 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

1.5+3.5+4.2+4.2 0.90 2.09 2.51 2.51 8.00 3.15 9.55 2.58 0.71 3.69 11.4 3.1 16.4 98 3.10 B 1290

1.5+3.5+4.2+5.0 0.85 1.97 2.37 2.82 8.00 3.26 9.58 2.53 0.71 3.64 11.2 3.1 16.1 98 3.16 B 1265

1.5+4.2+4.2+4.2 0.85 2.38 2.38 2.38 8.00 3.25 9.58 2.58 0.75 3.69 11.4 3.3 16.4 98 3.10 B 1290

2.0+2.0+2.0+2.0 1.83 1.83 1.83 1.83 7.32 2.41 7.90 2.07 0.56 2.38 9.2 2.5 10.6 98 3.54 A 1035

2.0+2.0+2.0+2.5 1.75 1.75 1.75 2.18 7.42 2.48 8.16 2.13 0.56 2.51 9.4 2.5 11.1 98 3.48 A 1065

2.0+2.0+2.0+3.5 1.61 1.61 1.61 2.82 7.65 2.61 8.62 2.26 0.60 2.86 10.0 2.7 12.7 98 3.38 A 1130

2.0+2.0+2.0+4.2 1.53 1.53 1.53 3.22 7.82 2.71 8.89 2.32 0.64 3.00 10.3 2.8 13.3 98 3.37 A 1160

2.0+2.0+2.0+5.0 1.45 1.45 1.45 3.64 8.00 2.82 9.15 2.52 0.64 3.32 11.2 2.8 14.7 98 3.17 B 1260

2.0+2.0+2.0+6.0 1.33 1.33 1.33 4.00 8.00 2.96 9.39 2.28 0.68 3.21 10.1 3.0 14.2 98 3.51 A 1140

2.0+2.0+2.0+7.1 1.22 1.22 1.22 4.34 8.00 3.11 9.55 2.22 0.68 3.29 9.8 3.0 14.6 98 3.60 A 1110

2.0+2.0+2.5+2.5 1.68 1.68 2.09 2.09 7.54 2.55 8.40 2.20 0.60 2.72 9.8 2.7 12.1 98 3.43 A 1100

2.0+2.0+2.5+3.5 1.55 1.55 1.94 2.72 7.77 2.68 8.82 2.45 0.60 3.14 10.9 2.7 13.9 98 3.17 B 1225

2.0+2.0+2.5+4.2 1.48 1.48 1.85 3.11 7.93 2.78 9.06 2.58 0.64 3.30 11.4 2.8 14.6 98 3.07 B 1290

2.0+2.0+2.5+5.0 1.39 1.39 1.74 3.48 8.00 2.89 9.28 2.52 0.64 3.39 11.2 2.8 15.0 98 3.17 B 1260

2.0+2.0+2.5+6.0 1.28 1.28 1.60 3.84 8.00 3.03 9.47 2.28 0.68 3.21 10.1 3.0 14.2 98 3.51 A 1140

2.0+2.0+2.5+7.1 1.18 1.18 1.47 4.18 8.00 3.18 9.59 2.22 0.72 3.29 9.8 3.2 14.6 98 3.60 A 1110

2.0+2.0+3.5+3.5 1.45 1.45 2.55 2.55 8.00 2.82 8.96 2.58 0.64 3.22 11.4 2.8 14.3 98 3.10 B 1290

2.0+2.0+3.5+4.2 1.37 1.37 2.39 2.87 8.00 2.92 9.32 2.58 0.67 3.53 11.4 3.0 15.7 98 3.10 B 1290

2.0+2.0+3.5+5.0 1.28 1.28 2.24 3.20 8.00 3.03 9.47 2.52 0.68 3.55 11.2 3.0 15.7 98 3.17 B 1260

2.0+2.0+3.5+6.0 1.19 1.19 2.07 3.56 8.00 3.16 9.58 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.0+2.0+4.2+4.2 1.29 1.29 2.71 2.71 8.00 3.01 9.46 2.58 0.67 3.61 11.4 3.0 16.0 98 3.10 B 1290

2.0+2.0+4.2+5.0 1.21 1.21 2.55 3.03 8.00 3.12 9.56 2.52 0.71 3.55 11.2 3.1 15.7 98 3.17 B 1260

2.0+2.0+4.2+6.0 1.13 1.13 2.37 3.38 8.00 3.26 9.60 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.0+2.0+5.0+5.0 1.14 1.14 2.86 2.86 8.00 3.23 9.60 2.44 0.71 3.50 10.8 3.1 15.5 98 3.28 A 1220

2.0+2.5+2.5+2.5 1.61 2.01 2.01 2.01 7.65 2.61 8.62 2.26 0.60 2.85 10.0 2.7 12.6 98 3.38 A 1130

2.0+2.5+2.5+3.5 1.50 1.88 1.88 2.63 7.88 2.75 8.99 2.51 0.64 3.29 11.1 2.8 14.6 98 3.14 B 1255

2.0+2.5+2.5+4.2 1.43 1.79 1.79 3.00 8.00 2.85 9.20 2.58 0.64 3.45 11.4 2.8 15.3 98 3.10 B 1290

2.0+2.5+2.5+5.0 1.33 1.67 1.67 3.33 8.00 2.96 9.39 2.52 0.68 3.47 11.2 3.0 15.4 98 3.17 B 1260

2.0+2.5+2.5+6.0 1.23 1.54 1.54 3.69 8.00 3.09 9.54 2.25 0.68 3.29 10.0 3.0 14.6 98 3.56 A 1125

2.0+2.5+2.5+7.1 1.13 1.42 1.42 4.03 8.00 3.25 9.60 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.0+2.5+3.5+3.5 1.39 1.74 2.43 2.43 8.00 2.89 9.14 2.58 0.67 3.37 11.4 3.0 15.0 98 3.10 B 1290

2.0+2.5+3.5+4.2 1.31 1.64 2.30 2.75 8.00 2.98 9.47 2.58 0.67 3.61 11.4 3.0 16.0 98 3.10 B 1290

2.0+2.5+3.5+5.0 1.23 1.54 2.15 3.08 8.00 3.09 9.54 2.52 0.71 3.55 11.2 3.1 15.7 98 3.17 B 1260

2.0+2.5+3.5+6.0 1.14 1.43 2.00 3.43 8.00 3.23 9.60 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.0+2.5+4.2+4.2 1.24 1.55 2.60 2.60 8.00 3.08 9.53 2.58 0.71 3.69 11.4 3.1 16.4 98 3.10 B 1290

2.0+2.5+4.2+5.0 1.17 1.46 2.45 2.92 8.00 3.19 9.59 2.52 0.71 3.63 11.2 3.1 16.1 98 3.17 B 1260

2.0+2.5+5.0+5.0 1.10 1.38 2.76 2.76 8.00 3.30 9.60 2.40 0.71 3.50 10.6 3.1 15.5 98 3.33 A 1200

2.0+3.5+3.5+3.5 1.28 2.24 2.24 2.24 8.00 3.03 9.23 2.58 0.67 3.30 11.4 3.0 14.6 98 3.10 B 1290

2.0+3.5+3.5+4.2 1.21 2.12 2.12 2.55 8.00 3.12 9.56 2.58 0.71 3.69 11.4 3.1 16.4 98 3.10 B 1290

2.0+3.5+3.5+5.0 1.14 2.00 2.00 2.86 8.00 3.23 9.60 2.52 0.71 3.63 11.2 3.1 16.1 98 3.17 B 1260

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

104

4MXS-E

GC_pre2_lowres.pdf 104 30/11/2011 12:31:08

Page 107: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR UNIT

INDOOR UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

2.0+3.5+4.2+4.2 1.15 2.01 2.42 2.42 8.00 3.22 9.60 2.58 0.71 3.77 11.4 3.1 16.7 98 3.10 B 1290

2.5+2.5+2.5+2.5 1.94 1.94 1.94 1.94 7.76 2.68 8.82 2.45 0.60 3.14 10.9 2.7 13.9 98 3.17 B 1225

2.5+2.5+2.5+3.5 1.82 1.82 1.82 2.55 8.00 2.82 8.98 2.58 0.64 3.22 11.4 2.8 14.3 98 3.10 B 1290

2.5+2.5+2.5+4.2 1.71 1.71 1.71 2.87 8.00 2.92 9.32 2.58 0.67 3.53 11.4 3.0 15.7 98 3.10 B 1290

2.5+2.5+2.5+5.0 1.60 1.60 1.60 3.20 8.00 3.03 9.47 2.52 0.68 3.55 11.2 3.0 15.7 98 3.17 B 1260

2.5+2.5+2.5+6.0 1.48 1.48 1.48 3.56 8.00 3.16 9.58 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.5+2.5+3.5+3.5 1.67 1.67 2.33 2.33 8.00 2.96 9.10 2.58 0.67 3.37 11.4 3.0 15.0 98 3.10 B 1290

2.5+2.5+3.5+4.2 1.57 1.57 2.20 2.65 8.00 3.05 9.50 2.58 0.67 3.69 11.4 3.0 16.4 98 3.10 B 1290

2.5+2.5+3.5+5.0 1.48 1.48 2.07 2.96 8.00 3.16 9.58 2.52 0.71 3.63 11.2 3.1 16.1 98 3.17 B 1260

2.5+2.5+3.5+6.0 1.38 1.38 1.93 3.31 8.00 3.30 9.60 2.28 0.72 3.29 10.1 3.2 14.6 98 3.51 A 1140

2.5+2.5+4.2+4.2 1.49 1.49 2.51 2.51 8.00 3.15 9.57 2.58 0.71 3.69 11.4 3.1 16.4 98 3.10 B 1290

2.5+2.5+4.2+5.0 1.41 1.41 2.37 2.82 8.00 3.26 9.60 2.52 0.71 3.63 11.2 3.1 16.1 98 3.17 B 1260

2.5+3.5+3.5+3.5 1.54 2.15 2.15 2.15 8.00 3.09 9.35 2.58 0.71 3.30 11.4 3.1 14.6 98 3.10 B 1290

2.5+3.5+3.5+4.2 1.46 2.04 2.04 2.45 8.00 3.19 9.59 2.58 0.71 3.77 11.4 3.1 16.7 98 3.10 B 1290

2.5+3.5+3.5+5.0 1.38 1.93 1.93 2.76 8.00 3.30 9.60 2.52 0.75 3.63 11.2 3.3 16.1 98 3.17 B 1260

2.5+3.5+4.2+4.2 1.39 1.94 2.33 2.33 8.00 3.29 9.60 2.58 0.75 3.77 11.4 3.3 16.7 98 3.10 B 1290

3.5+3.5+3.5+3.5 2.00 2.00 2.00 2.00 8.00 3.23 9.60 2.58 0.71 3.77 11.4 3.1 16.7 98 3.10 B 1290

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

105

4MXS-E

GC_pre2_lowres.pdf 105 30/11/2011 12:31:08

Page 108: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

1.5 2.22 --- --- --- 2.22 1.07 3.40 0.65 0.34 1.15 2.9 1.5 5.1 98 3.42 B

2.0 2.44 --- --- --- 2.44 1.07 4.10 0.67 0.37 1.22 3.0 1.6 5.4 98 3.64 A

2.5 3.05 --- --- --- 3.05 1.12 4.55 0.88 0.37 1.31 3.9 1.6 5.8 98 3.47 B

3.5 4.27 --- --- --- 4.27 1.21 5.11 1.42 0.39 1.73 6.3 1.7 7.7 98 3.01 D

4.2 5.12 --- --- --- 5.12 1.68 6.59 1.73 0.37 2.49 7.7 1.6 11.0 98 2.96 D

5.0 6.09 --- --- --- 6.09 1.90 7.12 1.78 0.44 2.25 7.9 2.0 10.0 98 3.42 B

6.0 7.31 --- --- --- 7.31 2.19 8.19 2.19 0.55 2.64 9.7 2.4 11.7 98 3.34 C

7.1 8.65 --- --- --- 8.65 2.50 9.00 2.77 0.59 2.97 12.3 2.6 13.2 98 3.12 D

1.5+1.5 1.83 1.83 --- --- 3.66 1.42 5.36 0.89 0.44 1.31 3.9 2.0 5.8 98 4.11 A

1.5+2.0 1.83 2.44 --- --- 4.27 1.48 5.36 1.01 0.44 1.31 4.5 2.0 5.8 98 4.23 A

1.5+2.5 1.83 3.05 --- --- 4.88 1.62 7.09 1.17 0.48 1.90 5.2 2.1 8.4 98 4.17 A

1.5+3.5 1.83 4.26 --- --- 6.09 1.90 7.23 1.64 0.55 2.08 7.3 2.4 9.2 98 3.71 A

1.5+4.2 1.83 5.12 --- --- 6.95 2.10 8.28 1.95 0.59 2.56 8.7 2.6 11.4 98 3.56 B

1.5+5.0 1.83 6.09 --- --- 7.92 2.33 8.72 2.10 0.53 2.42 9.3 2.4 10.7 98 3.77 A

1.5+6.0 1.79 7.14 --- --- 8.93 2.61 9.67 2.30 0.55 2.64 10.2 2.4 11.7 98 3.88 A

1.5+7.1 1.67 7.93 --- --- 9.60 2.90 9.90 2.48 0.58 2.63 11.0 2.6 11.7 98 3.87 A

2.0+2.0 2.44 2.44 --- --- 4.88 1.62 6.55 1.17 0.34 1.74 5.2 1.5 7.7 98 4.17 A

2.0+2.5 2.44 3.05 --- --- 5.49 1.76 6.85 1.34 0.37 1.82 5.9 1.6 8.1 98 4.10 A

2.0+3.5 2.44 4.26 --- --- 6.70 2.05 7.35 1.86 0.43 2.13 8.3 1.9 9.4 98 3.60 A

2.0+4.2 2.44 5.11 --- --- 7.55 2.24 8.53 2.22 0.47 2.56 9.8 2.1 11.4 98 3.40 B

2.0+5.0 2.44 6.09 --- --- 8.53 2.47 8.72 2.32 0.55 2.42 10.3 2.4 10.7 98 3.68 A

2.0+6.0 2.32 6.95 --- --- 9.27 2.74 9.67 2.44 0.57 2.64 10.8 2.5 11.7 98 3.80 A

2.0+7.1 2.11 7.49 --- --- 9.60 3.04 10.36 2.48 0.61 2.89 11.0 2.7 12.8 98 3.87 A

2.5+2.5 3.04 3.04 --- --- 6.08 1.90 7.16 1.69 0.41 2.14 7.5 1.8 9.5 98 3.60 B

2.5+3.5 3.05 4.26 --- --- 7.31 2.19 8.53 2.13 0.55 2.67 9.4 2.4 11.8 98 3.43 B

2.5+4.2 3.04 5.12 --- --- 8.16 2.39 9.01 2.46 0.57 2.90 10.9 2.5 12.9 98 3.32 C

2.5+5.0 2.98 5.95 --- --- 8.93 2.61 9.31 2.52 0.57 2.72 11.2 2.5 12.1 98 3.54 B

2.5+6.0 2.82 6.78 --- --- 9.60 2.88 10.10 2.65 0.59 2.94 11.8 2.6 13.0 98 3.62 A

2.5+7.1 2.50 7.10 --- --- 9.60 3.17 10.36 2.51 0.63 2.93 11.1 2.8 13.0 98 3.82 A

3.5+3.5 4.26 4.26 --- --- 8.52 2.47 9.18 2.70 0.59 3.04 12.0 2.6 13.5 98 3.16 D

3.5+4.2 4.11 4.94 --- --- 9.05 2.66 9.77 2.98 0.61 3.47 13.2 2.7 15.4 98 3.04 D

3.5+5.0 3.95 5.65 --- --- 9.60 2.88 9.92 2.77 0.62 2.93 12.3 2.8 13.0 98 3.47 B

3.5+6.0 3.54 6.06 --- --- 9.60 3.15 10.34 2.49 0.61 2.90 11.0 2.7 12.9 98 3.86 A

3.5+7.1 3.17 6.43 --- --- 9.60 3.45 10.37 2.43 0.67 2.84 10.8 3.0 12.6 98 3.95 A

4.2+4.2 4.78 4.78 --- --- 9.55 2.85 9.60 2.65 0.63 2.65 11.8 2.8 11.8 98 3.60 A

4.2+5.0 4.38 5.22 --- --- 9.60 3.07 10.12 2.61 0.64 2.87 11.6 2.8 12.7 98 3.68 A

4.2+6.0 3.95 5.65 --- --- 9.60 3.34 10.35 2.44 0.65 2.84 10.8 2.9 12.6 98 3.93 A

4.2+7.1 3.57 6.03 --- --- 9.60 3.63 10.38 2.43 0.70 2.83 10.8 3.1 12.6 98 3.95 A

5.0+5.0 4.80 4.80 --- --- 9.60 3.28 10.24 2.52 0.67 2.83 11.2 3.0 12.6 98 3.81 A

5.0+6.0 4.36 5.24 --- --- 9.60 3.55 10.47 2.40 0.66 2.80 10.6 2.9 12.4 98 4.00 A

5.0+7.1 3.97 5.63 --- --- 9.60 3.85 10.50 2.38 0.70 2.79 10.6 3.1 12.4 98 4.03 A

6.0+6.0 4.80 4.80 --- --- 9.60 3.82 10.70 2.32 0.67 2.77 10.3 3.0 12.3 98 4.14 A

6.0+7.1 4.40 5.20 --- --- 9.60 4.12 10.73 2.31 0.71 2.76 10.2 3.1 12.2 98 4.16 A

7.1+7.1 4.80 4.80 --- --- 9.60 4.42 10.77 2.25 0.78 2.70 10.0 3.5 12.0 98 4.27 A

1.5+1.5+1.5 1.83 1.83 1.83 --- 5.49 1.76 7.22 1.16 0.43 1.71 5.1 1.9 7.6 98 4.73 A

1.5+1.5+2.0 1.83 1.83 2.44 --- 6.09 1.90 7.22 1.34 0.44 1.71 5.9 2.0 7.6 98 4.54 A

1.5+1.5+2.5 1.83 1.83 3.05 --- 6.70 2.05 7.29 1.52 0.46 1.71 6.7 2.0 7.6 98 4.41 A

1.5+1.5+3.5 1.83 1.83 4.26 --- 7.92 2.33 9.03 1.90 0.50 2.30 8.4 2.2 10.2 98 4.17 A

1.5+1.5+4.2 1.82 1.82 5.09 --- 8.72 2.53 9.03 2.20 0.52 2.29 9.8 2.3 10.2 98 3.96 A

1.5+1.5+5.0 1.74 1.74 5.79 --- 9.27 2.74 9.99 2.25 0.53 2.54 10.0 2.4 11.3 98 4.12 A

1.5+1.5+6.0 1.60 1.60 6.40 --- 9.60 3.01 10.71 2.27 0.54 2.72 10.1 2.4 12.1 98 4.23 A

1.5+1.5+7.1 1.43 1.43 6.75 --- 9.60 3.31 10.74 2.26 0.57 2.71 10.0 2.5 12.0 98 4.25 A

1.5+2.0+2.0 1.83 2.44 2.44 --- 6.70 2.05 7.22 1.52 0.46 1.71 6.7 2.0 7.6 98 4.41 A

1.5+2.0+2.5 1.83 2.44 3.05 --- 7.31 2.19 8.41 1.71 0.48 2.12 7.6 2.1 9.4 98 4.27 A

1.5+2.0+3.5 1.83 2.44 4.27 --- 8.53 2.47 9.03 2.11 0.52 2.30 9.4 2.3 10.2 98 4.04 A

1.5+2.0+4.2 1.76 2.35 4.94 --- 9.06 2.66 9.69 2.29 0.54 2.58 10.2 2.4 11.4 98 3.96 A

1.5+2.0+5.0 1.69 2.26 5.65 --- 9.60 2.88 9.99 2.39 0.55 2.54 10.6 2.4 11.3 98 4.02 A

1.5+2.0+6.0 1.52 2.02 6.06 --- 9.60 3.15 10.71 2.27 0.56 2.72 10.1 2.5 12.1 98 4.23 A

1.5+2.0+7.1 1.36 1.81 6.43 --- 9.60 3.45 10.74 2.26 0.60 2.71 10.0 2.7 12.0 98 4.25 A

1.5+2.5+2.5 1.83 3.05 3.05 --- 7.92 2.33 8.93 1.94 0.50 2.30 8.6 2.2 10.2 98 4.08 A

1.5+2.5+3.5 1.79 2.98 4.17 --- 8.93 2.61 9.68 2.25 0.54 2.58 10.0 2.4 11.4 98 3.97 A

1.5+2.5+4.2 1.72 2.87 4.82 --- 9.41 2.80 9.69 2.43 0.56 2.58 10.8 2.5 11.4 98 3.87 A

1.5+2.5+5.0 1.60 2.67 5.33 --- 9.60 3.01 10.48 2.39 0.57 2.80 10.6 2.5 12.4 98 4.02 A

1.5+2.5+6.0 1.44 2.40 5.76 --- 9.60 3.28 10.71 2.27 0.58 2.72 10.1 2.6 12.1 98 4.23 A

1.5+2.5+7.1 1.30 2.16 6.14 --- 9.60 3.58 10.74 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

1.5+3.5+3.5 1.69 3.95 3.95 --- 9.60 2.88 9.89 2.43 0.59 2.58 10.8 2.6 11.4 98 3.95 A

1.5+3.5+4.2 1.57 3.65 4.38 --- 9.60 3.07 10.36 2.43 0.61 2.84 10.8 2.7 12.6 98 3.95 A

1.5+3.5+5.0 1.44 3.36 4.80 --- 9.60 3.28 10.49 2.39 0.61 2.79 10.6 2.7 12.4 98 4.02 A

1.5+3.5+6.0 1.31 3.05 5.24 --- 9.60 3.55 10.72 2.27 0.62 2.72 10.1 2.8 12.1 98 4.23 A

1.5+3.5+7.1 1.19 2.78 5.63 --- 9.60 3.85 10.75 2.26 0.66 2.70 10.0 2.9 12.0 98 4.25 A

1.5+4.2+4.2 1.45 4.07 4.07 --- 9.60 3.26 10.37 2.43 0.63 2.84 10.8 2.8 12.6 98 3.95 A

1.5+4.2+5.0 1.35 3.77 4.49 --- 9.60 3.47 10.49 2.39 0.66 2.79 10.6 2.9 12.4 98 4.02 A

1.5+4.2+6.0 1.23 3.45 4.92 --- 9.60 3.74 10.72 2.27 0.64 2.71 10.1 2.8 12.0 98 4.23 A

1.5+4.2+7.1 1.13 3.15 5.33 --- 9.60 4.04 10.76 2.26 0.71 2.70 10.0 3.1 12.0 98 4.25 A

1.5+5.0+5.0 1.25 4.17 4.17 --- 9.60 3.69 10.62 2.30 0.66 2.75 10.2 2.9 12.2 98 4.17 A

1.5+5.0+6.0 1.15 3.84 4.61 --- 9.60 3.96 10.85 2.18 0.67 2.72 9.7 3.0 12.1 98 4.40 A

1.5+5.0+7.1 1.06 3.53 5.01 --- 9.60 4.26 10.88 2.17 0.71 2.71 9.6 3.1 12.0 98 4.42 A

1.5+6.0+6.0 1.07 4.27 4.27 --- 9.60 4.23 11.08 2.11 0.68 2.64 9.4 3.0 11.7 98 4.55 A

2.0+2.0+2.0 2.43 2.43 2.43 --- 7.29 2.19 8.33 1.76 0.48 2.14 7.8 2.1 9.5 98 4.14 A

2.0+2.0+2.5 2.44 2.44 3.04 --- 7.92 2.33 8.93 1.96 0.50 2.32 8.7 2.2 10.3 98 4.04 A

2.0+2.0+3.5 2.38 2.38 4.17 --- 8.93 2.61 9.68 2.29 0.54 2.63 10.2 2.4 11.7 98 3.90 A

2.0+2.0+4.2 2.30 2.30 4.81 --- 9.41 2.80 9.69 2.48 0.56 2.63 11.0 2.5 11.7 98 3.79 A

2.0+2.0+5.0 2.13 2.13 5.34 --- 9.60 3.01 10.48 2.39 0.57 2.80 10.6 2.5 12.4 98 4.02 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

106

4MXS-E

GC_pre2_lowres.pdf 106 30/11/2011 12:31:09

Page 109: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

2.0+2.0+6.0 1.92 1.92 5.76 --- 9.60 3.28 10.71 2.27 0.58 2.72 10.1 2.6 12.1 98 4.23 A

2.0+2.0+7.1 1.73 1.73 6.14 --- 9.60 3.58 10.74 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

2.0+2.5+2.5 2.43 3.05 3.05 --- 8.53 2.47 8.93 2.16 0.52 2.30 9.6 2.3 10.2 98 3.95 A

2.0+2.5+3.5 2.31 2.90 4.06 --- 9.27 2.74 9.68 2.41 0.56 2.61 10.7 2.5 11.6 98 3.85 A

2.0+2.5+4.2 2.21 2.76 4.63 --- 9.60 2.93 10.15 2.56 0.59 2.87 11.4 2.6 12.7 98 3.75 A

2.0+2.5+5.0 2.02 2.53 5.05 --- 9.60 3.15 10.48 2.39 0.59 2.80 10.6 2.6 12.4 98 4.02 A

2.0+2.5+6.0 1.82 2.29 5.49 --- 9.60 3.42 10.71 2.27 0.60 2.72 10.1 2.7 12.1 98 4.23 A

2.0+2.5+7.1 1.65 2.07 5.88 --- 9.60 3.72 10.74 2.26 0.64 2.71 10.0 2.8 12.0 98 4.25 A

2.0+3.5+3.5 2.14 3.73 3.73 --- 9.60 3.01 10.35 2.43 0.59 2.84 10.8 2.6 12.6 98 3.95 A

2.0+3.5+4.2 1.99 3.46 4.15 --- 9.60 3.20 10.36 2.43 0.63 2.84 10.8 2.8 12.6 98 3.95 A

2.0+3.5+5.0 1.83 3.20 4.57 --- 9.60 3.42 10.49 2.39 0.63 2.80 10.6 2.8 12.4 98 4.02 A

2.0+3.5+6.0 1.67 2.92 5.01 --- 9.60 3.69 10.72 2.27 0.64 2.72 10.1 2.8 12.1 98 4.23 A

2.0+3.5+7.1 1.52 2.67 5.41 --- 9.60 3.99 10.75 2.26 0.69 2.70 10.0 3.1 12.0 98 4.25 A

2.0+4.2+4.2 1.84 3.88 3.88 --- 9.60 3.39 10.37 2.43 0.65 2.84 10.8 2.9 12.6 98 3.95 A

2.0+4.2+5.0 1.71 3.60 4.29 --- 9.60 3.61 10.49 2.39 0.68 2.79 10.6 3.0 12.4 98 4.02 A

2.0+4.2+6.0 1.58 3.30 4.72 --- 9.60 3.88 10.72 2.27 0.67 2.71 10.1 3.0 12.0 98 4.23 A

2.0+4.2+7.1 1.45 3.03 5.12 --- 9.60 4.18 10.76 2.26 0.73 2.70 10.0 3.2 12.0 98 4.25 A

2.0+5.0+5.0 1.60 4.00 4.00 --- 9.60 3.82 10.62 2.30 0.68 2.75 10.2 3.0 12.2 98 4.17 A

2.0+5.0+6.0 1.48 3.69 4.43 --- 9.60 4.09 10.85 2.18 0.69 2.72 9.7 3.1 12.1 98 4.40 A

2.0+5.0+7.1 1.37 3.40 4.83 --- 9.60 4.39 10.88 2.17 0.74 2.71 9.6 3.3 12.0 98 4.42 A

2.0+6.0+6.0 1.38 4.11 4.11 --- 9.60 4.36 11.08 2.11 0.70 2.64 9.4 3.1 11.7 98 4.55 A

2.5+2.5+2.5 2.97 2.97 2.97 --- 8.91 2.61 9.88 2.34 0.54 2.74 10.4 2.4 12.2 98 3.81 A

2.5+2.5+3.5 2.82 2.82 3.96 --- 9.60 2.88 10.12 2.53 0.59 2.79 11.2 2.6 12.4 98 3.79 A

2.5+2.5+4.2 2.61 2.61 4.38 --- 9.60 3.07 10.60 2.53 0.61 3.05 11.2 2.7 13.5 98 3.79 A

2.5+2.5+5.0 2.40 2.40 4.80 --- 9.60 3.28 10.48 2.39 0.61 2.80 10.6 2.7 12.4 98 4.02 A

2.5+2.5+6.0 2.18 2.18 5.24 --- 9.60 3.55 10.71 2.27 0.62 2.72 10.1 2.8 12.1 98 4.23 A

2.5+2.5+7.1 1.98 1.98 5.64 --- 9.60 3.85 10.74 2.26 0.66 2.71 10.0 2.9 12.0 98 4.25 A

2.5+3.5+3.5 2.52 3.54 3.54 --- 9.60 3.15 10.35 2.43 0.61 2.84 10.8 2.7 12.6 98 3.95 A

2.5+3.5+4.2 2.36 3.29 3.95 --- 9.60 3.34 10.36 2.43 0.65 2.84 10.8 2.9 12.6 98 3.95 A

2.5+3.5+5.0 2.19 3.05 4.36 --- 9.60 3.55 10.49 2.39 0.66 2.80 10.6 2.9 12.4 98 4.02 A

2.5+3.5+6.0 2.00 2.80 4.80 --- 9.60 3.82 10.72 2.27 0.67 2.72 10.1 3.0 12.1 98 4.23 A

2.5+3.5+7.1 1.84 2.56 5.20 --- 9.60 4.12 10.75 2.26 0.71 2.70 10.0 3.1 12.0 98 4.25 A

2.5+4.2+4.2 2.20 3.70 3.70 --- 9.60 3.53 10.37 2.43 0.68 2.84 10.8 3.0 12.6 98 3.95 A

2.5+4.2+5.0 2.06 3.45 4.09 --- 9.60 3.74 10.49 2.39 0.70 2.79 10.6 3.1 12.4 98 4.02 A

2.5+4.2+6.0 1.90 3.17 4.53 --- 9.60 4.01 10.72 2.27 0.69 2.71 10.1 3.1 12.0 98 4.23 A

2.5+4.2+7.1 1.75 2.92 4.93 --- 9.60 4.31 10.76 2.26 0.76 2.70 10.0 3.4 12.0 98 4.25 A

2.5+5.0+5.0 1.92 3.84 3.84 --- 9.60 3.96 10.62 2.30 0.71 2.75 10.2 3.1 12.2 98 4.17 A

2.5+5.0+6.0 1.77 3.56 4.27 --- 9.60 4.23 10.85 2.18 0.72 2.72 9.7 3.2 12.1 98 4.40 A

2.5+6.0+6.0 1.66 3.97 3.97 --- 9.60 4.50 11.08 2.11 0.72 2.64 9.4 3.2 11.7 98 4.55 A

3.5+3.5+3.5 3.20 3.20 3.20 --- 9.60 3.42 10.36 2.43 0.65 2.84 10.8 2.9 12.6 98 3.95 A

3.5+3.5+4.2 3.00 3.00 3.60 --- 9.60 3.61 10.37 2.43 0.70 2.84 10.8 3.1 12.6 98 3.95 A

3.5+3.5+5.0 2.80 2.80 4.00 --- 9.60 3.82 10.49 2.39 0.70 2.79 10.6 3.1 12.4 98 4.02 A

3.5+3.5+6.0 2.58 2.58 4.44 --- 9.60 4.09 10.72 2.27 0.71 2.71 10.1 3.1 12.0 98 4.23 A

3.5+3.5+7.1 2.38 2.38 4.84 --- 9.60 4.39 10.76 2.26 0.76 2.70 10.0 3.4 12.0 98 4.25 A

3.5+4.2+4.2 2.82 3.39 3.39 --- 9.60 3.80 10.38 2.43 0.72 2.83 10.8 3.2 12.6 98 3.95 A

3.5+4.2+5.0 2.65 3.17 3.78 --- 9.60 4.01 10.50 2.39 0.75 2.79 10.6 3.3 12.4 98 4.02 A

3.5+4.2+6.0 2.45 2.94 4.21 --- 9.60 4.28 10.73 2.26 0.74 2.71 10.0 3.3 12.0 98 4.25 A

3.5+5.0+5.0 2.48 3.56 3.56 --- 9.60 4.23 10.63 2.30 0.76 2.75 10.2 3.4 12.2 98 4.17 A

3.5+5.0+6.0 2.32 3.31 3.97 --- 9.60 4.50 10.86 2.18 0.77 2.72 9.7 3.4 12.1 98 4.40 A

4.2+4.2+4.2 3.20 3.20 3.20 --- 9.60 3.99 10.38 2.42 0.75 2.83 10.7 3.3 12.6 98 3.97 A

4.2+4.2+5.0 3.01 3.01 3.58 --- 9.60 4.20 10.51 2.38 0.78 2.79 10.6 3.5 12.4 98 4.03 A

4.2+4.2+6.0 2.80 2.80 4.00 --- 9.60 4.47 10.74 2.26 0.79 2.71 10.0 3.5 12.0 98 4.25 A

4.2+5.0+5.0 2.84 3.38 3.38 --- 9.60 4.42 10.64 2.29 0.81 2.74 10.2 3.6 12.2 98 4.19 A

1.5+1.5+1.5+1.5 1.83 1.83 1.83 1.83 7.31 2.19 8.47 1.64 0.41 2.00 7.3 1.8 8.9 98 4.46 A

1.5+1.5+1.5+2.0 1.83 1.83 1.83 2.44 7.92 2.33 9.04 1.83 0.42 2.22 8.1 1.9 9.8 98 4.33 A

1.5+1.5+1.5+2.5 1.83 1.83 1.83 3.05 8.53 2.47 9.13 2.00 0.44 2.22 8.9 2.0 9.8 98 4.27 A

1.5+1.5+1.5+3.5 1.74 1.74 1.74 4.06 9.27 2.74 10.18 2.17 0.48 2.51 9.6 2.1 11.1 98 4.27 A

1.5+1.5+1.5+4.2 1.66 1.66 1.66 4.63 9.60 2.93 10.73 2.26 0.51 2.71 10.0 2.3 12.0 98 4.25 A

1.5+1.5+1.5+5.0 1.52 1.52 1.52 5.05 9.60 3.15 10.86 2.18 0.52 2.72 9.7 2.3 12.1 98 4.40 A

1.5+1.5+1.5+6.0 1.37 1.37 1.37 5.49 9.60 3.42 11.09 2.10 0.52 2.64 9.3 2.3 11.7 98 4.57 A

1.5+1.5+1.5+7.1 1.24 1.24 1.24 5.88 9.60 3.72 11.12 2.09 0.56 2.63 9.3 2.5 11.7 98 4.59 A

1.5+1.5+2.0+2.0 1.83 1.83 2.44 2.44 8.53 2.47 9.04 2.04 0.44 2.22 9.1 2.0 9.8 98 4.18 A

1.5+1.5+2.0+2.5 1.79 1.79 2.38 2.98 8.93 2.61 9.87 2.13 0.46 2.51 9.4 2.0 11.1 98 4.19 A

1.5+1.5+2.0+3.5 1.69 1.69 2.26 3.95 9.60 2.88 10.18 2.27 0.52 2.51 10.1 2.3 11.1 98 4.23 A

1.5+1.5+2.0+4.2 1.57 1.57 2.09 4.38 9.60 3.07 10.73 2.26 0.53 2.71 10.0 2.4 12.0 98 4.25 A

1.5+1.5+2.0+5.0 1.44 1.44 1.92 4.80 9.60 3.28 10.86 2.18 0.54 2.72 9.7 2.4 12.1 98 4.40 A

1.5+1.5+2.0+6.0 1.31 1.31 1.75 5.24 9.60 3.55 11.09 2.10 0.54 2.64 9.3 2.4 11.7 98 4.57 A

1.5+1.5+2.0+7.1 1.19 1.19 1.59 5.63 9.60 3.85 11.12 2.09 0.58 2.63 9.3 2.6 11.7 98 4.59 A

1.5+1.5+2.5+2.5 1.74 1.74 2.90 2.90 9.27 2.74 10.17 2.18 0.48 2.51 9.7 2.1 11.1 98 4.25 A

1.5+1.5+2.5+3.5 1.60 1.60 2.67 3.73 9.60 3.01 10.72 2.27 0.54 2.71 10.1 2.4 12.0 98 4.23 A

1.5+1.5+2.5+4.2 1.48 1.48 2.47 4.16 9.60 3.20 10.73 2.26 0.55 2.71 10.0 2.4 12.0 98 4.25 A

1.5+1.5+2.5+5.0 1.37 1.37 2.29 4.57 9.60 3.42 10.86 2.18 0.56 2.72 9.7 2.5 12.1 98 4.40 A

1.5+1.5+2.5+6.0 1.25 1.25 2.09 5.01 9.60 3.69 11.09 2.10 0.57 2.64 9.3 2.5 11.7 98 4.57 A

1.5+1.5+2.5+7.1 1.14 1.14 1.90 5.41 9.60 3.99 11.12 2.09 0.62 2.63 9.3 2.8 11.7 98 4.59 A

1.5+1.5+3.5+3.5 1.44 1.44 3.36 3.36 9.60 3.28 10.73 2.26 0.58 2.71 10.0 2.6 12.0 98 4.25 A

1.5+1.5+3.5+4.2 1.35 1.35 3.14 3.77 9.60 3.47 10.74 2.26 0.60 2.71 10.0 2.7 12.0 98 4.25 A

1.5+1.5+3.5+5.0 1.25 1.25 2.92 4.17 9.60 3.69 10.86 2.17 0.62 2.71 9.6 2.8 12.0 98 4.42 A

1.5+1.5+3.5+6.0 1.15 1.15 2.69 4.61 9.60 3.96 11.09 2.10 0.61 2.63 9.3 2.7 11.7 98 4.57 A

1.5+1.5+3.5+7.1 1.06 1.06 2.47 5.01 9.60 4.26 11.13 2.09 0.67 2.62 9.3 3.0 11.6 98 4.59 A

1.5+1.5+4.2+4.2 1.26 1.26 3.54 3.54 9.60 3.66 10.75 2.26 0.64 2.70 10.0 2.8 12.0 98 4.25 A

1.5+1.5+4.2+5.0 1.18 1.18 3.30 3.93 9.60 3.88 10.87 2.17 0.64 2.71 9.6 2.8 12.0 98 4.42 A

1.5+1.5+4.2+6.0 1.09 1.09 3.05 4.36 9.60 4.15 11.10 2.10 0.65 2.63 9.3 2.9 11.7 98 4.57 A

1.5+1.5+4.2+7.1 1.01 1.01 2.82 4.77 9.60 4.45 11.13 2.09 0.69 2.62 9.3 3.1 11.6 98 4.59 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

107

4MXS-E

GC_pre2_lowres.pdf 107 30/11/2011 12:31:09

Page 110: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

1.5+1.5+5.0+5.0 1.11 1.11 3.69 3.69 9.60 4.09 11.00 2.13 0.67 2.67 9.4 3.0 11.8 98 4.51 A

1.5+1.5+5.0+6.0 1.03 1.03 3.43 4.11 9.60 4.36 11.23 2.01 0.67 2.59 8.9 3.0 11.5 98 4.78 A

1.5+2.0+2.0+2.0 1.79 2.38 2.38 2.38 8.93 2.61 9.78 2.18 0.46 2.51 9.7 2.0 11.1 98 4.10 A

1.5+2.0+2.0+2.5 1.74 2.32 2.32 2.90 9.27 2.74 9.87 2.27 0.48 2.51 10.1 2.1 11.1 98 4.08 A

1.5+2.0+2.0+3.5 1.60 2.13 2.13 3.73 9.60 3.01 10.72 2.27 0.54 2.71 10.1 2.4 12.0 98 4.23 A

1.5+2.0+2.0+4.2 1.48 1.98 1.98 4.16 9.60 3.20 10.73 2.26 0.55 2.71 10.0 2.4 12.0 98 4.25 A

1.5+2.0+2.0+5.0 1.37 1.83 1.83 4.57 9.60 3.42 10.86 2.18 0.56 2.72 9.7 2.5 12.1 98 4.40 A

1.5+2.0+2.0+6.0 1.25 1.67 1.67 5.01 9.60 3.69 11.09 2.10 0.57 2.64 9.3 2.5 11.7 98 4.57 A

1.5+2.0+2.0+7.1 1.14 1.52 1.52 5.41 9.60 3.99 11.12 2.09 0.62 2.63 9.3 2.8 11.7 98 4.59 A

1.5+2.0+2.5+2.5 1.69 2.26 2.82 2.82 9.60 2.88 10.17 2.27 0.52 2.51 10.1 2.3 11.1 98 4.23 A

1.5+2.0+2.5+3.5 1.52 2.02 2.53 3.54 9.60 3.15 10.72 2.27 0.56 2.71 10.1 2.5 12.0 98 4.23 A

1.5+2.0+2.5+4.2 1.41 1.88 2.35 3.95 9.60 3.34 10.73 2.26 0.58 2.71 10.0 2.6 12.0 98 4.25 A

1.5+2.0+2.5+5.0 1.31 1.75 2.18 4.36 9.60 3.55 10.86 2.18 0.60 2.72 9.7 2.7 12.1 98 4.40 A

1.5+2.0+2.5+6.0 1.20 1.60 2.00 4.80 9.60 3.82 11.09 2.10 0.59 2.64 9.3 2.6 11.7 98 4.57 A

1.5+2.0+2.5+7.1 1.10 1.47 1.83 5.20 9.60 4.12 11.12 2.09 0.65 2.63 9.3 2.9 11.7 98 4.59 A

1.5+2.0+3.5+3.5 1.37 1.83 3.20 3.20 9.60 3.42 10.73 2.26 0.60 2.71 10.0 2.7 12.0 98 4.25 A

1.5+2.0+3.5+4.2 1.29 1.71 3.00 3.60 9.60 3.61 10.74 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

1.5+2.0+3.5+5.0 1.20 1.60 2.80 4.00 9.60 3.82 10.86 2.17 0.64 2.71 9.6 2.8 12.0 98 4.42 A

1.5+2.0+3.5+6.0 1.11 1.48 2.58 4.43 9.60 4.09 11.09 2.10 0.65 2.63 9.3 2.9 11.7 98 4.57 A

1.5+2.0+3.5+7.1 1.02 1.36 2.38 4.83 9.60 4.39 11.13 2.09 0.69 2.62 9.3 3.1 11.6 98 4.59 A

1.5+2.0+4.2+4.2 1.21 1.61 3.39 3.39 9.60 3.80 10.75 2.26 0.66 2.70 10.0 2.9 12.0 98 4.25 A

1.5+2.0+4.2+5.0 1.13 1.51 3.17 3.78 9.60 4.01 10.87 2.17 0.67 2.71 9.6 3.0 12.0 98 4.42 A

1.5+2.0+4.2+6.0 1.05 1.40 2.94 4.20 9.60 4.28 11.10 2.10 0.67 2.63 9.3 3.0 11.7 98 4.57 A

1.5+2.0+5.0+5.0 1.07 1.42 3.56 3.56 9.60 4.23 11.00 2.13 0.69 2.67 9.4 3.1 11.8 98 4.51 A

1.5+2.0+5.0+6.0 0.99 1.32 3.31 3.97 9.60 4.50 11.23 2.01 0.70 2.59 8.9 3.1 11.5 98 4.78 A

1.5+2.5+2.5+2.5 1.60 2.67 2.67 2.67 9.60 3.01 10.71 2.27 0.54 2.72 10.1 2.4 12.1 98 4.23 A

1.5+2.5+2.5+3.5 1.44 2.40 2.40 3.36 9.60 3.28 10.72 2.27 0.58 2.71 10.1 2.6 12.0 98 4.23 A

1.5+2.5+2.5+4.2 1.35 2.24 2.24 3.77 9.60 3.47 10.73 2.26 0.60 2.71 10.0 2.7 12.0 98 4.25 A

1.5+2.5+2.5+5.0 1.25 2.09 2.09 4.17 9.60 3.69 10.86 2.18 0.62 2.72 9.7 2.8 12.1 98 4.40 A

1.5+2.5+2.5+6.0 1.15 1.92 1.92 4.61 9.60 3.96 11.09 2.10 0.61 2.64 9.3 2.7 11.7 98 4.57 A

1.5+2.5+2.5+7.1 1.06 1.76 1.76 5.01 9.60 4.26 11.12 2.09 0.67 2.63 9.3 3.0 11.7 98 4.59 A

1.5+2.5+3.5+3.5 1.31 2.18 3.05 3.05 9.60 3.55 10.73 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

1.5+2.5+3.5+4.2 1.23 2.05 2.87 3.45 9.60 3.74 10.74 2.26 0.64 2.71 10.0 2.8 12.0 98 4.25 A

1.5+2.5+3.5+5.0 1.15 1.92 2.69 3.84 9.60 3.96 10.86 2.17 0.67 2.71 9.6 3.0 12.0 98 4.42 A

1.5+2.5+3.5+6.0 1.07 1.78 2.49 4.27 9.60 4.23 11.09 2.10 0.67 2.63 9.3 3.0 11.7 98 4.57 A

1.5+2.5+4.2+4.2 1.16 1.94 3.25 3.25 9.60 3.93 10.75 2.26 0.69 2.70 10.0 3.1 12.0 98 4.25 A

1.5+2.5+4.2+5.0 1.09 1.82 3.05 3.64 9.60 4.15 10.87 2.17 0.69 2.71 9.6 3.1 12.0 98 4.42 A

1.5+2.5+4.2+6.0 1.01 1.69 2.84 4.06 9.60 4.42 11.10 2.10 0.70 2.63 9.3 3.1 11.7 98 4.57 A

1.5+2.5+5.0+5.0 1.03 1.71 3.43 3.43 9.60 4.36 11.00 2.13 0.71 2.67 9.4 3.1 11.8 98 4.51 A

1.5+3.5+3.5+3.5 1.20 2.80 2.80 2.80 9.60 3.82 10.74 2.26 0.66 2.71 10.0 2.9 12.0 98 4.25 A

1.5+3.5+3.5+4.2 1.13 2.65 2.65 3.17 9.60 4.01 10.75 2.26 0.69 2.70 10.0 3.1 12.0 98 4.25 A

1.5+3.5+3.5+5.0 1.07 2.49 2.49 3.56 9.60 4.23 10.87 2.17 0.71 2.71 9.6 3.1 12.0 98 4.42 A

1.5+3.5+3.5+6.0 0.99 2.32 2.32 3.97 9.60 4.50 11.10 2.10 0.72 2.63 9.3 3.2 11.7 98 4.57 A

1.5+3.5+4.2+4.2 1.07 2.51 3.01 3.01 9.60 4.20 10.75 2.26 0.73 2.70 10.0 3.2 12.0 98 4.25 A

1.5+3.5+4.2+5.0 1.01 2.37 2.84 3.38 9.60 4.42 10.88 2.17 0.74 2.71 9.6 3.3 12.0 98 4.42 A

1.5+4.2+4.2+4.2 1.02 2.86 2.86 2.86 9.60 4.39 10.76 2.25 0.76 2.70 10.0 3.4 12.0 98 4.27 A

2.0+2.0+2.0+2.0 2.32 2.32 2.32 2.32 9.28 2.74 9.78 2.27 0.48 2.51 10.1 2.1 11.1 98 4.09 A

2.0+2.0+2.0+2.5 2.26 2.26 2.26 2.82 9.60 2.88 9.92 2.36 0.52 2.51 10.5 2.3 11.1 98 4.07 A

2.0+2.0+2.0+3.5 2.02 2.02 2.02 3.54 9.60 3.15 10.72 2.27 0.56 2.71 10.1 2.5 12.0 98 4.23 A

2.0+2.0+2.0+4.2 1.88 1.88 1.88 3.96 9.60 3.34 10.73 2.26 0.58 2.71 10.0 2.6 12.0 98 4.25 A

2.0+2.0+2.0+5.0 1.75 1.75 1.75 4.35 9.60 3.55 10.86 2.18 0.60 2.72 9.7 2.7 12.1 98 4.40 A

2.0+2.0+2.0+6.0 1.60 1.60 1.60 4.80 9.60 3.82 11.09 2.10 0.59 2.64 9.3 2.6 11.7 98 4.57 A

2.0+2.0+2.0+7.1 1.47 1.47 1.47 5.19 9.60 4.12 11.12 2.09 0.65 2.63 9.3 2.9 11.7 98 4.59 A

2.0+2.0+2.5+2.5 2.13 2.13 2.67 2.67 9.60 3.01 10.71 2.27 0.54 2.72 10.1 2.4 12.1 98 4.23 A

2.0+2.0+2.5+3.5 1.92 1.92 2.40 3.36 9.60 3.28 10.72 2.27 0.58 2.71 10.1 2.6 12.0 98 4.23 A

2.0+2.0+2.5+4.2 1.79 1.79 2.25 3.77 9.60 3.47 10.73 2.26 0.60 2.71 10.0 2.7 12.0 98 4.25 A

2.0+2.0+2.5+5.0 1.67 1.67 2.09 4.17 9.60 3.69 10.86 2.18 0.62 2.72 9.7 2.8 12.1 98 4.40 A

2.0+2.0+2.5+6.0 1.54 1.54 1.92 4.60 9.60 3.96 11.09 2.10 0.61 2.64 9.3 2.7 11.7 98 4.57 A

2.0+2.0+2.5+7.1 1.41 1.41 1.76 5.02 9.60 4.26 11.12 2.09 0.67 2.63 9.3 3.0 11.7 98 4.59 A

2.0+2.0+3.5+3.5 1.75 1.75 3.05 3.05 9.60 3.55 10.73 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

2.0+2.0+3.5+4.2 1.64 1.64 2.87 3.45 9.60 3.74 10.74 2.26 0.64 2.71 10.0 2.8 12.0 98 4.25 A

2.0+2.0+3.5+5.0 1.54 1.54 2.69 3.83 9.60 3.96 10.86 2.17 0.67 2.71 9.6 3.0 12.0 98 4.42 A

2.0+2.0+3.5+6.0 1.42 1.42 2.49 4.27 9.60 4.23 11.09 2.10 0.67 2.63 9.3 3.0 11.7 98 4.57 A

2.0+2.0+4.2+4.2 1.55 1.55 3.25 3.25 9.60 3.93 10.75 2.26 0.66 2.70 10.0 2.9 12.0 98 4.25 A

2.0+2.0+4.2+5.0 1.45 1.45 3.06 3.64 9.60 4.15 10.87 2.17 0.69 2.71 9.6 3.1 12.0 98 4.42 A

2.0+2.0+4.2+6.0 1.35 1.35 2.84 4.06 9.60 4.42 11.10 2.10 0.70 2.63 9.3 3.1 11.7 98 4.57 A

2.0+2.0+5.0+5.0 1.37 1.37 3.43 3.43 9.60 4.36 11.00 2.13 0.72 2.67 9.4 3.2 11.8 98 4.51 A

2.0+2.5+2.5+2.5 2.01 2.53 2.53 2.53 9.60 3.15 10.71 2.27 0.56 2.72 10.1 2.5 12.1 98 4.23 A

2.0+2.5+2.5+3.5 1.82 2.29 2.29 3.20 9.60 3.42 10.72 2.27 0.60 2.71 10.1 2.7 12.0 98 4.23 A

2.0+2.5+2.5+4.2 1.72 2.14 2.14 3.60 9.60 3.61 10.73 2.26 0.62 2.71 10.0 2.8 12.0 98 4.25 A

2.0+2.5+2.5+5.0 1.60 2.00 2.00 4.00 9.60 3.82 10.86 2.18 0.65 2.72 9.7 2.9 12.1 98 4.40 A

2.0+2.5+2.5+6.0 1.47 1.85 1.85 4.43 9.60 4.09 11.09 2.10 0.65 2.64 9.3 2.9 11.7 98 4.57 A

2.0+2.5+2.5+7.1 1.37 1.70 1.70 4.83 9.60 4.39 11.12 2.09 0.69 2.63 9.3 3.1 11.7 98 4.59 A

2.0+2.5+3.5+3.5 1.67 2.09 2.92 2.92 9.60 3.69 10.73 2.26 0.64 2.71 10.0 2.8 12.0 98 4.25 A

2.0+2.5+3.5+4.2 1.58 1.97 2.75 3.30 9.60 3.88 10.74 2.26 0.66 2.71 10.0 2.9 12.0 98 4.25 A

2.0+2.5+3.5+5.0 1.48 1.85 2.58 3.69 9.60 4.09 10.86 2.18 0.69 2.71 9.7 3.1 12.0 98 4.40 A

2.0+2.5+3.5+6.0 1.38 1.71 2.40 4.11 9.60 4.36 11.09 2.10 0.70 2.63 9.3 3.1 11.7 98 4.57 A

2.0+2.5+4.2+4.2 1.50 1.86 3.12 3.12 9.60 4.07 10.75 2.26 0.69 2.70 10.0 3.1 12.0 98 4.25 A

2.0+2.5+4.2+5.0 1.41 1.75 2.94 3.50 9.60 4.28 10.87 2.17 0.71 2.71 9.6 3.1 12.0 98 4.42 A

2.0+2.5+5.0+5.0 1.32 1.66 3.31 3.31 9.60 4.50 11.00 2.13 0.74 2.67 9.4 3.3 11.8 98 4.51 A

2.0+3.5+3.5+3.5 1.53 2.69 2.69 2.69 9.60 3.96 10.74 2.26 0.69 2.71 10.0 3.1 12.0 98 4.25 A

2.0+3.5+3.5+4.2 1.45 2.55 2.55 3.05 9.60 4.15 10.75 2.26 0.71 2.70 10.0 3.1 12.0 98 4.25 A

2.0+3.5+3.5+5.0 1.37 2.40 2.40 3.43 9.60 4.36 10.87 2.17 0.74 2.71 9.6 3.3 12.0 98 4.42 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

108

4MXS-E

GC_pre2_lowres.pdf 108 30/11/2011 12:31:09

Page 111: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT

INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

4MXS80E7V3B

2.0+3.5+4.2+4.2 1.38 2.42 2.90 2.90 9.60 4.34 10.75 2.26 0.76 2.70 10.0 3.4 12.0 98 4.25 A

2.5+2.5+2.5+2.5 2.40 2.40 2.40 2.40 9.60 3.28 10.71 2.27 0.58 2.72 10.1 2.6 12.1 98 4.23 A

2.5+2.5+2.5+3.5 2.18 2.18 2.18 3.06 9.60 3.55 10.72 2.27 0.62 2.71 10.1 2.8 12.0 98 4.23 A

2.5+2.5+2.5+4.2 2.05 2.05 2.05 3.45 9.60 3.74 10.73 2.26 0.64 2.71 10.0 2.8 12.0 98 4.25 A

2.5+2.5+2.5+5.0 1.92 1.92 1.92 3.84 9.60 3.96 10.86 2.18 0.67 2.72 9.7 3.0 12.1 98 4.40 A

2.5+2.5+2.5+6.0 1.78 1.78 1.78 4.26 9.60 4.23 11.09 2.10 0.68 2.64 9.3 3.0 11.7 98 4.57 A

2.5+2.5+3.5+3.5 2.00 2.00 2.80 2.80 9.60 3.82 10.73 2.26 0.67 2.71 10.0 3.0 12.0 98 4.25 A

2.5+2.5+3.5+4.2 1.89 1.89 2.65 3.17 9.60 4.01 10.74 2.26 0.69 2.71 10.0 3.1 12.0 98 4.25 A

2.5+2.5+3.5+5.0 1.78 1.78 2.49 3.55 9.60 4.23 10.86 2.18 0.71 2.71 9.7 3.1 12.0 98 4.40 A

2.5+2.5+3.5+6.0 1.66 1.66 2.32 3.96 9.60 4.50 11.09 2.10 0.72 2.63 9.3 3.2 11.7 98 4.57 A

2.5+2.5+4.2+4.2 1.79 1.79 3.01 3.01 9.60 4.20 10.75 2.26 0.71 2.70 10.0 3.1 12.0 98 4.25 A

2.5+2.5+4.2+5.0 1.69 1.69 2.85 3.37 9.60 4.42 10.87 2.17 0.76 2.71 9.6 3.4 12.0 98 4.42 A

2.5+3.5+3.5+3.5 1.86 2.58 2.58 2.58 9.60 4.09 10.74 2.26 0.71 2.71 10.0 3.1 12.0 98 4.25 A

2.5+3.5+3.5+4.2 1.76 2.45 2.45 2.94 9.60 4.28 10.75 2.26 0.74 2.70 10.0 3.3 12.0 98 4.25 A

2.5+3.5+3.5+5.0 1.65 2.32 2.32 3.31 9.60 4.50 10.87 2.17 0.76 2.71 9.6 3.4 12.0 98 4.42 A

2.5+3.5+4.2+4.2 1.67 2.33 2.80 2.80 9.60 4.47 10.75 2.26 0.78 2.70 10.0 3.5 12.0 98 4.25 A

3.5+3.5+3.5+3.5 2.40 2.40 2.40 2.40 9.60 4.36 10.75 2.26 0.76 2.70 10.0 3.4 12.0 98 4.25 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

109

4MXS-E

GC_pre2_lowres.pdf 109 30/11/2011 12:31:09

Page 112: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5 1.50 --- --- --- --- 1.47 1.50 2.22 0.30 0.54 0.68 1.3 2.4 3.0 98 2.78 D 270

2.0 2.00 --- --- --- --- 1.49 2.00 3.03 0.30 0.56 1.02 1.3 2.5 4.5 98 3.57 A 280

2.5 2.50 --- --- --- --- 1.51 2.50 3.54 0.30 0.71 1.18 1.3 3.1 5.2 98 3.52 A 355

3.5 3.50 --- --- --- --- 1.55 3.50 4.82 0.34 1.14 1.47 1.5 5.1 6.5 98 3.07 B 570

4.2 4.20 --- --- --- --- 2.13 4.20 5.14 0.56 1.38 1.69 2.5 6.1 7.5 98 3.04 B 690

5.0 5.00 --- --- --- --- 2.22 5.00 5.50 0.49 1.64 1.83 2.2 7.3 8.1 98 3.05 B 820

6.0 6.00 --- --- --- --- 2.33 6.00 6.60 0.50 1.89 2.24 2.2 8.4 9.9 98 3.17 B 945

7.1 7.10 --- --- --- --- 2.45 7.10 7.38 0.53 2.57 2.74 2.4 11.4 12.2 98 2.76 D 1285

1.5+1.5 1.50 1.50 --- --- --- 2.03 3.00 4.03 0.46 0.78 1.14 2.0 3.5 5.1 98 3.85 A 390

1.5+2.0 1.50 2.00 --- --- --- 2.05 3.50 4.50 0.50 0.94 1.34 2.2 4.2 5.9 98 3.72 A 470

1.5+2.5 1.50 2.50 --- --- --- 2.11 4.00 4.96 0.46 1.06 1.38 2.0 4.7 6.1 98 3.77 A 530

1.5+3.5 1.50 3.50 --- --- --- 2.22 5.00 5.82 0.46 1.43 1.79 2.0 6.3 7.9 98 3.50 A 715

1.5+4.2 1.50 4.20 --- --- --- 2.29 5.70 6.37 0.46 1.75 2.09 2.0 7.8 9.3 98 3.26 A 875

1.5+5.0 1.50 5.00 --- --- --- 2.38 6.50 6.97 0.50 2.10 2.42 2.2 9.3 10.7 98 3.10 B 1050

1.5+6.0 1.45 5.79 --- --- --- 2.51 7.24 7.64 0.54 2.34 2.57 2.4 10.4 11.4 98 3.09 B 1170

1.5+7.1 1.33 6.30 --- --- --- 2.67 7.63 8.29 0.57 2.57 3.00 2.5 11.4 13.3 98 2.97 C 1285

2.0+2.0 2.00 2.00 --- --- --- 2.11 4.00 5.30 0.50 1.14 1.79 2.2 5.1 7.9 98 3.51 A 570

2.0+2.5 2.00 2.50 --- --- --- 2.16 4.50 5.73 0.50 1.30 1.79 2.2 5.8 7.9 98 3.46 A 650

2.0+3.5 2.00 3.50 --- --- --- 2.27 5.50 6.36 0.50 1.70 2.09 2.2 7.5 9.3 98 3.24 A 850

2.0+4.2 2.00 4.20 --- --- --- 2.35 6.20 6.75 0.50 1.99 2.35 2.2 8.8 10.4 98 3.12 B 995

2.0+5.0 2.00 5.00 --- --- --- 2.44 7.00 7.31 0.50 2.42 2.59 2.2 10.7 11.5 98 2.89 C 1210

2.0+6.0 1.86 5.56 --- --- --- 2.58 7.42 7.96 0.54 2.45 2.81 2.4 10.9 12.5 98 3.03 B 1225

2.0+7.1 1.71 6.09 --- --- --- 2.74 7.80 8.47 0.57 2.69 3.13 2.5 11.9 13.9 98 2.90 C 1345

2.5+2.5 2.50 2.50 --- --- --- 2.22 5.00 6.20 0.46 1.39 1.99 2.0 6.2 8.8 98 3.60 A 695

2.5+3.5 2.50 3.50 --- --- --- 2.33 6.00 6.60 0.50 1.89 2.25 2.2 8.4 10.0 98 3.17 B 945

2.5+4.2 2.50 4.20 --- --- --- 2.41 6.70 7.11 0.50 2.30 2.57 2.2 10.2 11.4 98 2.91 C 1150

2.5+5.0 2.41 4.83 --- --- --- 2.51 7.24 7.64 0.53 2.59 2.82 2.4 11.5 12.5 98 2.80 D 1295

2.5+6.0 2.23 5.36 --- --- --- 2.66 7.59 8.25 0.57 2.57 3.00 2.5 11.4 13.3 98 2.95 C 1285

2.5+7.1 2.08 5.90 --- --- --- 2.82 7.98 8.47 0.60 2.81 3.13 2.7 12.5 13.9 98 2.84 C 1405

3.5+3.5 3.50 3.50 --- --- --- 2.44 7.00 7.31 0.53 2.52 2.69 2.4 11.2 11.9 98 2.78 D 1260

3.5+4.2 3.32 3.99 --- --- --- 2.54 7.31 7.66 0.53 2.69 2.92 2.4 11.9 13.0 98 2.72 D 1345

3.5+5.0 3.13 4.46 --- --- --- 2.66 7.59 7.83 0.57 2.82 2.94 2.5 12.5 13.0 98 2.69 D 1410

3.5+6.0 2.93 5.01 --- --- --- 2.80 7.94 8.45 0.60 2.81 3.13 2.7 12.5 13.9 98 2.83 C 1405

3.5+7.1 2.75 5.58 --- --- --- 2.96 8.33 8.47 0.64 3.07 3.13 2.8 13.6 13.9 98 2.71 D 1535

4.2+4.2 3.78 3.78 --- --- --- 2.64 7.56 7.67 0.56 2.86 2.92 2.5 12.7 13.0 98 2.64 D 1430

4.2+5.0 3.58 4.26 --- --- --- 2.76 7.84 8.01 0.60 2.94 3.07 2.7 13.0 13.6 98 2.67 D 1470

4.2+6.0 3.37 4.82 --- --- --- 2.91 8.19 8.46 0.60 2.94 3.13 2.7 13.0 13.9 98 2.79 D 1470

4.2+7.1 3.19 5.39 --- --- --- 3.07 8.58 8.66 0.64 3.26 3.26 2.8 14.5 14.5 98 2.63 D 1630

5.0+5.0 4.06 4.06 --- --- --- 2.88 8.12 8.18 0.60 3.09 3.19 2.7 13.7 14.2 98 2.63 D 1545

5.0+6.0 3.85 4.62 --- --- --- 3.02 8.47 8.64 0.64 3.09 3.25 2.8 13.7 14.4 98 2.74 D 1545

5.0+7.1 3.66 5.20 --- --- --- 3.19 8.86 8.88 0.67 3.36 3.39 3.0 14.9 15.0 98 2.64 D 1680

6.0+6.0 4.41 4.41 --- --- --- 3.17 8.82 9.27 0.64 3.08 3.36 2.8 13.7 14.9 98 2.86 C 1540

6.0+7.1 4.12 4.88 --- --- --- 3.33 9.00 9.29 0.68 3.08 3.36 3.0 13.7 14.9 98 2.92 C 1540

7.1+7.1 4.50 4.50 --- --- --- 3.49 9.00 9.31 0.71 3.02 3.36 3.1 13.4 14.9 98 2.98 C 1510

1.5+1.5+1.5 1.50 1.50 1.50 --- --- 2.16 4.50 5.40 0.47 1.05 1.39 2.1 4.7 6.2 98 4.29 A 525

1.5+1.5+2.0 1.50 1.50 2.00 --- --- 2.22 5.00 5.82 0.47 1.22 1.57 2.1 5.4 7.0 98 4.10 A 610

1.5+1.5+2.5 1.50 1.50 2.50 --- --- 2.27 5.50 6.22 0.47 1.43 1.76 2.1 6.3 7.8 98 3.85 A 715

1.5+1.5+3.5 1.50 1.50 3.50 --- --- 2.38 6.50 6.97 0.50 1.91 2.17 2.2 8.5 9.6 98 3.40 A 955

1.5+1.5+4.2 1.49 1.49 4.17 --- --- 2.46 7.14 7.45 0.50 2.28 2.45 2.2 10.1 10.9 98 3.13 B 1140

1.5+1.5+5.0 1.39 1.39 4.64 --- --- 2.58 7.42 7.96 0.54 2.35 2.71 2.4 10.4 12.0 98 3.16 B 1175

1.5+1.5+6.0 1.30 1.30 5.18 --- --- 2.73 7.77 8.53 0.58 2.38 2.82 2.6 10.6 12.5 98 3.26 A 1190

1.5+1.5+7.1 1.21 1.21 5.74 --- --- 2.89 8.16 9.07 0.61 2.56 3.22 2.7 11.4 14.3 98 3.19 B 1280

1.5+2.0+2.0 1.50 2.00 2.00 --- --- 2.27 5.50 6.22 0.50 1.43 1.76 2.2 6.3 7.8 98 3.85 A 715

1.5+2.0+2.5 1.50 2.00 2.50 --- --- 2.33 6.00 6.60 0.47 1.66 1.96 2.1 7.4 8.7 98 3.61 A 830

1.5+2.0+3.5 1.50 2.00 3.50 --- --- 2.44 7.00 7.31 0.50 2.17 2.40 2.2 9.6 10.6 98 3.23 A 1085

1.5+2.0+4.2 1.42 1.90 3.99 --- --- 2.54 7.31 7.77 0.54 2.40 2.69 2.4 10.6 11.9 98 3.05 B 1200

1.5+2.0+5.0 1.34 1.79 4.46 --- --- 2.66 7.59 8.25 0.54 2.47 2.89 2.4 11.0 12.8 98 3.07 B 1235

1.5+2.0+6.0 1.25 1.67 5.01 --- --- 2.80 7.94 8.78 0.58 2.44 3.01 2.6 10.8 13.4 98 3.25 A 1220

1.5+2.0+7.1 1.18 1.57 5.58 --- --- 2.96 8.33 9.12 0.61 2.69 3.22 2.7 11.9 14.3 98 3.10 B 1345

1.5+2.5+2.5 1.50 2.50 2.50 --- --- 2.38 6.50 6.97 0.50 1.91 2.17 2.2 8.5 9.6 98 3.40 A 955

1.5+2.5+3.5 1.45 2.41 3.38 --- --- 2.51 7.24 7.64 0.54 2.34 2.57 2.4 10.4 11.4 98 3.09 B 1170

1.5+2.5+4.2 1.37 2.28 3.84 --- --- 2.61 7.49 8.08 0.54 2.45 2.88 2.4 10.9 12.8 98 3.06 B 1225

1.5+2.5+5.0 1.30 2.16 4.32 --- --- 2.73 7.77 8.53 0.57 2.59 3.09 2.5 11.5 13.7 98 3.00 C 1295

1.5+2.5+6.0 1.22 2.03 4.87 --- --- 2.88 8.12 9.03 0.58 2.56 3.22 2.6 11.4 14.3 98 3.17 B 1280

1.5+2.5+7.1 1.15 1.92 5.44 --- --- 3.04 8.51 9.30 0.61 2.82 3.36 2.7 12.5 14.9 98 3.02 B 1410

1.5+3.5+3.5 1.34 3.13 3.13 --- --- 2.66 7.59 8.25 0.57 2.57 3.00 2.5 11.4 13.3 98 2.95 C 1285

1.5+3.5+4.2 1.28 2.98 3.58 --- --- 2.76 7.84 8.48 0.57 2.69 3.13 2.5 11.9 13.9 98 2.91 C 1345

1.5+3.5+5.0 1.22 2.84 4.06 --- --- 2.88 8.12 8.66 0.61 2.83 3.16 2.7 12.6 14.0 98 2.87 C 1415

1.5+3.5+6.0 1.16 2.70 4.62 --- --- 3.02 8.47 9.11 0.61 2.82 3.22 2.7 12.5 14.3 98 3.00 B 1410

1.5+3.5+7.1 1.10 2.56 5.20 --- --- 3.19 8.86 9.31 0.64 3.08 3.36 2.8 13.7 14.9 98 2.88 C 1540

1.5+4.2+4.2 1.23 3.43 3.43 --- --- 2.86 8.09 8.49 0.60 2.88 3.13 2.7 12.8 13.9 98 2.81 C 1440

1.5+4.2+5.0 1.17 3.29 3.91 --- --- 2.98 8.37 8.67 0.61 2.96 3.16 2.7 13.1 14.0 98 2.83 C 1480

1.5+4.2+6.0 1.12 3.13 4.47 --- --- 3.13 8.72 9.30 0.64 2.95 3.36 2.8 13.1 14.9 98 2.96 C 1475

1.5+4.2+7.1 1.05 2.95 4.99 --- --- 3.29 9.00 9.32 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

1.5+5.0+5.0 1.13 3.76 3.76 --- --- 3.10 8.65 9.02 0.64 3.05 3.32 2.8 13.5 14.7 98 2.84 C 1525

1.5+5.0+6.0 1.08 3.60 4.32 --- --- 3.24 9.00 9.47 0.64 2.97 3.39 2.8 13.2 15.0 98 3.03 B 1485

1.5+5.0+7.1 0.99 3.31 4.70 --- --- 3.41 9.00 9.49 0.68 2.90 3.39 3.0 12.9 15.0 98 3.10 B 1450

1.5+6.0+6.0 1.00 4.00 4.00 --- --- 3.39 9.00 9.93 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

1.5+6.0+7.1 0.92 3.70 4.38 --- --- 3.55 9.00 9.95 0.71 2.61 3.46 3.1 11.6 15.4 98 3.45 A 1305

2.0+2.0+2.0 2.00 2.00 2.00 --- --- 2.33 6.00 6.63 0.50 1.66 1.96 2.2 7.4 8.7 98 3.61 A 830

2.0+2.0+2.5 2.00 2.00 2.50 --- --- 2.38 6.50 6.97 0.50 1.91 2.17 2.2 8.5 9.6 98 3.40 A 955

2.0+2.0+3.5 1.93 1.93 3.38 --- --- 2.51 7.24 7.64 0.54 2.34 2.57 2.4 10.4 11.4 98 3.09 B 1170

2.0+2.0+4.2 1.83 1.83 3.83 --- --- 2.61 7.49 8.08 0.54 2.45 2.88 2.4 10.9 12.8 98 3.06 B 1225

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

110

5MXS-E

GC_pre2_lowres.pdf 110 30/11/2011 12:31:10

Page 113: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

2.0+2.0+5.0 1.72 1.72 4.33 --- --- 2.73 7.77 8.53 0.57 2.59 3.09 2.5 11.5 13.7 98 3.00 C 1295

2.0+2.0+6.0 1.62 1.62 4.88 --- --- 2.88 8.12 9.03 0.58 2.56 3.22 2.6 11.4 14.3 98 3.17 B 1280

2.0+2.0+7.1 1.53 1.53 5.45 --- --- 3.04 8.51 9.30 0.61 2.82 3.36 2.7 12.5 14.9 98 3.02 B 1410

2.0+2.5+2.5 2.00 2.50 2.50 --- --- 2.44 7.00 7.31 0.50 2.17 2.40 2.2 9.6 10.6 98 3.23 A 1085

2.0+2.5+3.5 1.86 2.32 3.24 --- --- 2.58 7.42 7.96 0.54 2.45 2.81 2.4 10.9 12.5 98 3.03 B 1225

2.0+2.5+4.2 1.76 2.20 3.70 --- --- 2.69 7.66 8.36 0.57 2.57 3.07 2.5 11.4 13.6 98 2.98 C 1285

2.0+2.5+5.0 1.67 2.09 4.18 --- --- 2.80 7.94 8.65 0.57 2.71 3.15 2.5 12.0 14.0 98 2.93 C 1355

2.0+2.5+6.0 1.58 1.98 4.74 --- --- 2.95 8.30 9.10 0.61 2.69 3.22 2.7 11.9 14.3 98 3.09 B 1345

2.0+2.5+7.1 1.50 1.87 5.31 --- --- 3.11 8.68 9.30 0.64 2.95 3.36 2.8 13.1 14.9 98 2.94 C 1475

2.0+3.5+3.5 1.73 3.02 3.02 --- --- 2.73 7.77 8.47 0.57 2.69 3.13 2.5 11.9 13.9 98 2.89 C 1345

2.0+3.5+4.2 1.65 2.89 3.47 --- --- 2.83 8.01 8.48 0.60 2.81 3.13 2.7 12.5 13.9 98 2.85 C 1405

2.0+3.5+5.0 1.58 2.77 3.95 --- --- 2.95 8.30 8.66 0.61 2.96 3.16 2.7 13.1 14.0 98 2.80 C 1480

2.0+3.5+6.0 1.50 2.63 4.52 --- --- 3.10 8.65 9.29 0.64 2.95 3.36 2.8 13.1 14.9 98 2.93 C 1475

2.0+3.5+7.1 1.43 2.50 5.07 --- --- 3.26 9.00 9.31 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.0+4.2+4.2 1.58 3.34 3.34 --- --- 2.94 8.26 8.49 0.60 3.00 3.13 2.7 13.3 13.9 98 2.75 D 1500

2.0+4.2+5.0 1.53 3.20 3.81 --- --- 3.05 8.54 8.84 0.64 3.09 3.29 2.8 13.7 14.6 98 2.76 D 1545

2.0+4.2+6.0 1.46 3.06 4.37 --- --- 3.20 8.89 9.30 0.64 3.08 3.36 2.8 13.7 14.9 98 2.89 C 1540

2.0+4.2+7.1 1.36 2.84 4.80 --- --- 3.36 9.00 9.32 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.0+5.0+5.0 1.46 3.68 3.68 --- --- 3.17 8.82 9.02 0.64 3.18 3.32 2.8 14.1 14.7 98 2.77 D 1590

2.0+5.0+6.0 1.39 3.46 4.15 --- --- 3.32 9.00 9.47 0.68 2.97 3.39 3.0 13.2 15.0 98 3.03 B 1485

2.0+5.0+7.1 1.28 3.19 4.53 --- --- 3.48 9.00 9.49 0.71 2.90 3.39 3.1 12.9 15.0 98 3.10 B 1450

2.0+6.0+6.0 1.28 3.86 3.86 --- --- 3.46 9.00 9.93 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

2.0+6.0+7.1 1.19 3.58 4.23 --- --- 3.63 9.00 10.40 0.71 2.61 4.00 3.1 11.6 17.7 98 3.45 A 1305

2.5+2.5+2.5 2.41 2.41 2.41 --- --- 2.51 7.23 7.64 0.54 2.34 2.57 2.4 10.4 11.4 98 3.09 B 1170

2.5+2.5+3.5 2.23 2.23 3.13 --- --- 2.66 7.59 8.25 0.57 2.57 3.00 2.5 11.4 13.3 98 2.95 C 1285

2.5+2.5+4.2 2.13 2.13 3.58 --- --- 2.76 7.84 8.47 0.57 2.69 3.13 2.5 11.9 13.9 98 2.91 C 1345

2.5+2.5+5.0 2.03 2.03 4.06 --- --- 2.88 8.12 8.65 0.61 2.83 3.15 2.7 12.6 14.0 98 2.87 C 1415

2.5+2.5+6.0 1.93 1.93 4.61 --- --- 3.02 8.47 9.10 0.61 2.82 3.22 2.7 12.5 14.3 98 3.00 B 1410

2.5+2.5+7.1 1.83 1.83 5.20 --- --- 3.19 8.86 9.30 0.64 3.08 3.36 2.8 13.7 14.9 98 2.88 C 1540

2.5+3.5+3.5 2.08 2.93 2.93 --- --- 2.80 7.94 8.47 0.60 2.75 3.13 2.7 12.2 13.9 98 2.89 C 1375

2.5+3.5+4.2 2.01 2.81 3.37 --- --- 2.91 8.19 8.48 0.60 2.94 3.13 2.7 13.0 13.9 98 2.79 D 1470

2.5+3.5+5.0 1.93 2.70 3.84 --- --- 3.02 8.47 8.66 0.64 3.02 3.16 2.8 13.4 14.0 98 2.80 C 1510

2.5+3.5+6.0 1.84 2.57 4.41 --- --- 3.17 8.82 9.29 0.64 3.01 3.36 2.8 13.4 14.9 98 2.93 C 1505

2.5+3.5+7.1 1.72 2.40 4.88 --- --- 3.33 9.00 9.31 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.5+4.2+4.2 1.94 3.25 3.25 --- --- 3.01 8.44 8.44 0.64 3.13 3.13 2.8 13.9 13.9 98 2.70 D 1565

2.5+4.2+5.0 1.86 3.13 3.73 --- --- 3.13 8.72 8.84 0.64 3.22 3.29 2.8 14.3 14.6 98 2.71 D 1610

2.5+4.2+6.0 1.77 2.98 4.25 --- --- 3.27 9.00 9.30 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.5+4.2+7.1 1.63 2.74 4.63 --- --- 3.44 9.00 9.32 0.71 3.15 3.36 3.1 14.0 14.9 98 2.86 C 1575

2.5+5.0+5.0 1.80 3.60 3.60 --- --- 3.24 9.00 9.02 0.67 3.32 3.37 3.0 14.7 15.0 98 2.71 D 1660

2.5+5.0+6.0 1.67 3.33 4.00 --- --- 3.39 9.00 9.47 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

2.5+5.0+7.1 1.54 3.08 4.38 --- --- 3.55 9.00 9.49 0.71 2.97 3.39 3.1 13.2 15.0 98 3.03 B 1485

2.5+6.0+6.0 1.56 3.72 3.72 --- --- 3.54 9.00 9.93 0.71 2.75 3.46 3.1 12.2 15.4 98 3.27 A 1375

2.5+6.0+7.1 1.44 3.46 4.10 --- --- 3.70 9.00 10.40 0.71 2.68 4.00 3.1 11.9 17.7 98 3.36 A 1340

3.5+3.5+3.5 2.77 2.77 2.77 --- --- 2.95 8.31 8.60 0.64 3.07 3.26 2.8 13.6 14.5 98 2.71 D 1535

3.5+3.5+4.2 2.67 2.67 3.20 --- --- 3.05 8.54 8.66 0.64 3.20 3.26 2.8 14.2 14.5 98 2.67 D 1600

3.5+3.5+5.0 2.57 2.57 3.68 --- --- 3.17 8.82 8.84 0.67 3.29 3.32 3.0 14.6 14.7 98 2.68 D 1645

3.5+3.5+6.0 2.42 2.42 4.16 --- --- 3.32 9.00 9.30 0.68 3.08 3.36 3.0 13.7 14.9 98 2.92 C 1540

3.5+3.5+7.1 2.23 2.23 4.54 --- --- 3.48 9.00 9.32 0.71 3.02 3.36 3.1 13.4 14.9 98 2.98 C 1510

3.5+4.2+4.2 2.59 3.10 3.10 --- --- 3.16 8.79 8.79 0.67 3.26 3.26 3.0 14.5 14.5 98 2.70 D 1630

3.5+4.2+5.0 2.48 2.98 3.54 --- --- 3.27 9.00 9.00 0.67 3.29 3.29 3.0 14.6 14.6 98 2.74 D 1645

3.5+4.2+6.0 2.30 2.76 3.94 --- --- 3.42 9.00 9.31 0.71 3.15 3.36 3.1 14.0 14.9 98 2.86 C 1575

3.5+4.2+7.1 2.13 2.55 4.32 --- --- 3.58 9.00 9.81 0.75 3.15 3.95 3.3 14.0 17.5 98 2.86 C 1575

3.5+5.0+5.0 2.34 3.33 3.33 --- --- 3.39 9.00 9.02 0.71 3.32 3.35 3.1 14.7 14.9 98 2.71 D 1660

3.5+5.0+6.0 2.18 3.10 3.72 --- --- 3.54 9.00 9.48 0.71 3.04 3.39 3.1 13.5 15.0 98 2.96 C 1520

3.5+5.0+7.1 2.02 2.88 4.10 --- --- 3.70 9.00 9.94 0.75 2.97 3.91 3.3 13.2 17.3 98 3.03 B 1485

3.5+6.0+6.0 2.04 3.48 3.48 --- --- 3.69 9.00 10.38 0.71 2.75 4.00 3.1 12.2 17.7 98 3.27 A 1375

4.2+4.2+4.2 3.00 3.00 3.00 --- --- 3.26 9.00 9.00 0.71 3.27 3.27 3.1 14.5 14.5 98 2.75 D 1635

4.2+4.2+5.0 2.82 2.82 3.36 --- --- 3.38 9.00 9.08 0.71 3.29 3.29 3.1 14.6 14.6 98 2.74 D 1645

4.2+4.2+6.0 2.63 2.63 3.74 --- --- 3.52 9.00 9.32 0.71 3.15 3.36 3.1 14.0 14.9 98 2.86 C 1575

4.2+4.2+7.1 2.44 2.44 4.12 --- --- 3.69 9.00 9.82 0.75 3.16 3.95 3.3 14.0 17.5 98 2.85 C 1580

4.2+5.0+5.0 2.66 3.17 3.17 --- --- 3.49 9.00 9.03 0.74 3.32 3.32 3.3 14.7 14.7 98 2.71 D 1660

4.2+5.0+6.0 2.49 2.96 3.55 --- --- 3.64 9.00 9.98 0.75 3.04 3.98 3.3 13.5 17.7 98 2.96 C 1520

5.0+5.0+5.0 3.00 3.00 3.00 --- --- 3.61 9.00 9.78 0.75 3.21 4.07 3.3 14.2 18.1 98 2.80 C 1605

1.5+1.5+1.5+1.5 1.50 1.50 1.50 1.50 --- 2.33 6.00 6.60 0.48 1.39 1.62 2.1 6.2 7.2 98 4.32 A 695

1.5+1.5+1.5+2.0 1.50 1.50 1.50 2.00 --- 2.38 6.50 6.97 0.51 1.58 1.82 2.3 7.0 8.1 98 4.11 A 790

1.5+1.5+1.5+2.5 1.50 1.50 1.50 2.50 --- 2.44 7.00 7.31 0.51 1.82 1.98 2.3 8.1 8.8 98 3.85 A 910

1.5+1.5+1.5+3.5 1.39 1.39 1.39 3.25 --- 2.58 7.42 7.96 0.54 2.04 2.32 2.4 9.1 10.3 98 3.64 A 1020

1.5+1.5+1.5+4.2 1.32 1.32 1.32 3.70 --- 2.69 7.66 8.36 0.54 2.26 2.69 2.4 10.0 11.9 98 3.39 A 1130

1.5+1.5+1.5+5.0 1.25 1.25 1.25 4.18 --- 2.80 7.94 8.78 0.58 2.33 2.90 2.6 10.3 12.9 98 3.41 A 1165

1.5+1.5+1.5+6.0 1.19 1.19 1.19 4.74 --- 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

1.5+1.5+1.5+7.1 1.12 1.12 1.12 5.31 --- 3.11 8.68 9.67 0.61 2.62 3.24 2.7 11.6 14.4 98 3.31 A 1310

1.5+1.5+2.0+2.0 1.50 1.50 2.00 2.00 --- 2.44 7.00 7.31 0.51 1.82 1.98 2.3 8.1 8.8 98 3.85 A 910

1.5+1.5+2.0+2.5 1.45 1.45 1.93 2.41 --- 2.51 7.24 7.64 0.51 1.93 2.15 2.3 8.6 9.5 98 3.75 A 965

1.5+1.5+2.0+3.5 1.34 1.34 1.79 3.13 --- 2.66 7.59 8.25 0.54 2.09 2.50 2.4 9.3 11.1 98 3.63 A 1045

1.5+1.5+2.0+4.2 1.28 1.28 1.70 3.58 --- 2.76 7.84 8.63 0.58 2.38 2.88 2.6 10.6 12.8 98 3.29 A 1190

1.5+1.5+2.0+5.0 1.22 1.22 1.62 4.06 --- 2.88 8.12 9.03 0.58 2.45 3.11 2.6 10.9 13.8 98 3.31 A 1225

1.5+1.5+2.0+6.0 1.16 1.16 1.54 4.62 --- 3.02 8.47 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

1.5+1.5+2.0+7.1 1.10 1.10 1.46 5.20 --- 3.19 8.86 9.84 0.65 2.68 3.39 2.9 11.9 15.0 98 3.31 A 1340

1.5+1.5+2.5+2.5 1.39 1.39 2.32 2.32 --- 2.58 7.42 7.96 0.54 2.04 2.32 2.4 9.1 10.3 98 3.64 A 1020

1.5+1.5+2.5+3.5 1.30 1.30 2.16 3.02 --- 2.73 7.77 8.53 0.58 2.32 2.82 2.6 10.3 12.5 98 3.35 A 1160

1.5+1.5+2.5+4.2 1.24 1.24 2.06 3.47 --- 2.83 8.01 8.88 0.58 2.50 3.08 2.6 11.1 13.7 98 3.20 A 1250

1.5+1.5+2.5+5.0 1.19 1.19 1.98 3.95 --- 2.95 8.30 9.25 0.61 2.58 3.25 2.7 11.4 14.4 98 3.22 A 1290

1.5+1.5+2.5+6.0 1.13 1.13 1.88 4.51 --- 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

111

5MXS-E

GC_pre2_lowres.pdf 111 30/11/2011 12:31:10

Page 114: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+1.5+2.5+7.1 1.07 1.07 1.79 5.07 --- 3.26 9.00 9.96 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

1.5+1.5+3.5+3.5 1.22 1.22 2.84 2.84 --- 2.88 8.12 9.03 0.58 2.56 3.15 2.6 11.4 14.0 98 3.17 B 1280

1.5+1.5+3.5+4.2 1.17 1.17 2.74 3.29 --- 2.98 8.37 9.14 0.61 2.69 3.22 2.7 11.9 14.3 98 3.11 B 1345

1.5+1.5+3.5+5.0 1.13 1.13 2.63 3.76 --- 3.10 8.65 9.49 0.64 2.84 3.39 2.8 12.6 15.0 98 3.05 B 1420

1.5+1.5+3.5+6.0 1.08 1.08 2.52 4.32 --- 3.24 9.00 9.95 0.64 2.75 3.46 2.8 12.2 15.4 98 3.27 A 1375

1.5+1.5+3.5+7.1 0.99 0.99 2.32 4.70 --- 3.41 9.00 9.97 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

1.5+1.5+4.2+4.2 1.13 1.13 3.17 3.17 --- 3.08 8.61 9.33 0.64 2.89 3.36 2.8 12.8 14.9 98 2.98 C 1445

1.5+1.5+4.2+5.0 1.09 1.09 3.06 3.64 --- 3.20 8.89 9.50 0.64 2.97 3.39 2.8 13.2 15.0 98 2.99 C 1485

1.5+1.5+4.2+6.0 1.02 1.02 2.86 4.09 --- 3.35 9.00 9.96 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

1.5+1.5+4.2+7.1 0.94 0.94 2.64 4.47 --- 3.51 9.00 9.98 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

1.5+1.5+5.0+5.0 1.04 1.04 3.46 3.46 --- 3.32 9.00 9.68 0.68 2.92 3.42 3.0 13.0 15.2 98 3.08 B 1460

1.5+1.5+5.0+6.0 0.96 0.96 3.21 3.86 --- 3.46 9.00 10.14 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+1.5+5.0+7.1 0.89 0.89 2.98 4.23 --- 3.63 9.00 10.46 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

1.5+1.5+6.0+6.0 0.90 0.90 3.60 3.60 --- 3.61 9.00 10.45 0.68 2.46 3.48 3.0 10.9 15.4 98 3.66 A 1230

1.5+2.0+2.0+2.0 1.45 1.93 1.93 1.93 --- 2.51 7.24 7.64 0.51 1.93 2.15 2.3 8.6 9.5 98 3.75 A 965

1.5+2.0+2.0+2.5 1.39 1.86 1.86 2.32 --- 2.58 7.42 7.96 0.54 2.04 2.32 2.4 9.1 10.3 98 3.64 A 1020

1.5+2.0+2.0+3.5 1.30 1.73 1.73 3.02 --- 2.73 7.77 8.53 0.58 2.21 2.63 2.6 9.8 11.7 98 3.52 A 1105

1.5+2.0+2.0+4.2 1.24 1.65 1.65 3.47 --- 2.83 8.01 8.88 0.58 2.50 3.08 2.6 11.1 13.7 98 3.20 A 1250

1.5+2.0+2.0+5.0 1.19 1.58 1.58 3.95 --- 2.95 8.30 9.25 0.61 2.58 3.25 2.7 11.4 14.4 98 3.22 A 1290

1.5+2.0+2.0+6.0 1.13 1.50 1.50 4.51 --- 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

1.5+2.0+2.0+7.1 1.07 1.43 1.43 5.07 --- 3.26 9.00 9.96 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

1.5+2.0+2.5+2.5 1.34 1.79 2.23 2.23 --- 2.66 7.59 8.25 0.54 2.09 2.50 2.4 9.3 11.1 98 3.63 A 1045

1.5+2.0+2.5+3.5 1.25 1.67 2.09 2.93 --- 2.80 7.94 8.78 0.58 2.44 3.02 2.6 10.8 13.4 98 3.25 A 1220

1.5+2.0+2.5+4.2 1.20 1.61 2.01 3.37 --- 2.91 8.19 9.12 0.61 2.63 3.22 2.7 11.7 14.3 98 3.11 B 1315

1.5+2.0+2.5+5.0 1.16 1.54 1.93 3.85 --- 3.02 8.47 9.30 0.61 2.71 3.25 2.7 12.0 14.4 98 3.13 B 1355

1.5+2.0+2.5+6.0 1.10 1.47 1.84 4.41 --- 3.17 8.82 9.81 0.64 2.68 3.38 2.8 11.9 15.0 98 3.29 A 1340

1.5+2.0+2.5+7.1 1.03 1.37 1.72 4.88 --- 3.33 9.00 9.96 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

1.5+2.0+3.5+3.5 1.19 1.58 2.77 2.77 --- 2.95 8.30 9.13 0.61 2.69 3.22 2.7 11.9 14.3 98 3.09 B 1345

1.5+2.0+3.5+4.2 1.14 1.53 2.67 3.20 --- 3.05 8.54 9.32 0.61 2.82 3.36 2.7 12.5 14.9 98 3.03 B 1410

1.5+2.0+3.5+5.0 1.10 1.47 2.57 3.68 --- 3.17 8.82 9.49 0.64 2.90 3.39 2.8 12.9 15.0 98 3.04 B 1450

1.5+2.0+3.5+6.0 1.04 1.38 2.42 4.15 --- 3.32 9.00 9.95 0.64 2.75 3.46 2.8 12.2 15.4 98 3.27 A 1375

1.5+2.0+3.5+7.1 0.96 1.28 2.23 4.53 --- 3.48 9.00 9.97 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

1.5+2.0+4.2+4.2 1.11 1.48 3.10 3.10 --- 3.16 8.79 9.33 0.64 3.02 3.36 2.8 13.4 14.9 98 2.91 C 1510

1.5+2.0+4.2+5.0 1.06 1.42 2.98 3.54 --- 3.27 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

1.5+2.0+4.2+6.0 0.99 1.31 2.76 3.94 --- 3.42 9.00 9.96 0.68 2.81 3.46 3.0 12.5 15.4 98 3.20 A 1405

1.5+2.0+4.2+7.1 0.91 1.22 2.55 4.32 --- 3.58 9.00 10.42 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

1.5+2.0+5.0+5.0 1.00 1.33 3.33 3.33 --- 3.39 9.00 9.68 0.68 2.92 3.42 3.0 13.0 15.2 98 3.08 B 1460

1.5+2.0+5.0+6.0 0.93 1.24 3.10 3.72 --- 3.54 9.00 10.14 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+2.0+5.0+7.1 0.87 1.15 2.88 4.10 --- 3.70 9.00 10.50 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

1.5+2.0+6.0+6.0 0.87 1.16 3.48 3.48 --- 3.69 9.00 10.49 0.71 2.46 3.48 3.1 10.9 15.4 98 3.66 A 1230

1.5+2.5+2.5+2.5 1.30 2.16 2.16 2.16 --- 2.73 7.77 8.53 0.58 2.21 2.69 2.6 9.8 11.9 98 3.52 A 1105

1.5+2.5+2.5+3.5 1.22 2.03 2.03 2.84 --- 2.88 8.12 9.03 0.58 2.56 3.22 2.6 11.4 14.3 98 3.17 B 1280

1.5+2.5+2.5+4.2 1.17 1.96 1.96 3.29 --- 2.98 8.37 9.13 0.61 2.69 3.22 2.7 11.9 14.3 98 3.11 B 1345

1.5+2.5+2.5+5.0 1.13 1.88 1.88 3.76 --- 3.10 8.65 9.49 0.64 2.84 3.39 2.8 12.6 15.0 98 3.05 B 1420

1.5+2.5+2.5+6.0 1.08 1.80 1.80 4.32 --- 3.24 9.00 9.94 0.64 2.75 3.46 2.8 12.2 15.4 98 3.27 A 1375

1.5+2.5+2.5+7.1 0.99 1.65 1.65 4.70 --- 3.41 9.00 9.96 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

1.5+2.5+3.5+3.5 1.16 1.93 2.70 2.70 --- 3.02 8.47 9.13 0.61 2.75 3.22 2.7 12.2 14.3 98 3.08 B 1375

1.5+2.5+3.5+4.2 1.12 1.86 2.61 3.13 --- 3.13 8.72 9.32 0.64 2.95 3.36 2.8 13.1 14.9 98 2.96 C 1475

1.5+2.5+3.5+5.0 1.08 1.80 2.52 3.60 --- 3.24 9.00 9.49 0.64 3.04 3.39 2.8 13.5 15.0 98 2.96 C 1520

1.5+2.5+3.5+6.0 1.00 1.67 2.33 4.00 --- 3.39 9.00 9.95 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

1.5+2.5+3.5+7.1 0.92 1.54 2.16 4.38 --- 3.55 9.00 9.97 0.71 2.68 3.46 3.1 11.9 15.4 98 3.36 A 1340

1.5+2.5+4.2+4.2 1.08 1.81 3.03 3.03 --- 3.23 8.96 9.33 0.64 3.09 3.36 2.8 13.7 14.9 98 2.90 C 1545

1.5+2.5+4.2+5.0 1.02 1.70 2.86 3.41 --- 3.35 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

1.5+2.5+4.2+6.0 0.95 1.58 2.66 3.80 --- 3.49 9.00 9.96 0.68 2.81 3.46 3.0 12.5 15.4 98 3.20 A 1405

1.5+2.5+4.2+7.1 0.88 1.47 2.47 4.18 --- 3.66 9.00 10.47 0.71 2.75 4.09 3.1 12.2 18.1 98 3.27 A 1375

1.5+2.5+5.0+5.0 0.96 1.60 3.20 3.20 --- 3.23 8.96 9.33 0.64 3.09 3.36 2.8 13.7 14.9 98 2.90 C 1545

1.5+2.5+5.0+6.0 0.90 1.50 3.00 3.60 --- 3.35 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

1.5+3.5+3.5+3.5 1.10 2.57 2.57 2.57 --- 3.17 8.82 9.32 0.64 3.02 3.36 2.8 13.4 14.9 98 2.92 C 1510

1.5+3.5+3.5+4.2 1.06 2.48 2.48 2.98 --- 3.27 9.00 9.33 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

1.5+3.5+3.5+5.0 1.00 2.33 2.33 3.33 --- 3.39 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

1.5+3.5+3.5+6.0 0.93 2.17 2.17 3.72 --- 3.54 9.00 9.96 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

1.5+3.5+3.5+7.1 0.87 2.02 2.02 4.10 --- 3.70 9.00 10.50 0.71 2.75 4.17 3.1 12.2 18.5 98 3.27 A 1375

1.5+3.5+4.2+4.2 1.01 2.35 2.82 2.82 --- 3.38 9.00 9.33 0.68 3.16 3.37 3.0 14.0 15.0 98 2.85 C 1580

1.5+3.5+4.2+5.0 0.95 2.22 2.66 3.17 --- 3.49 9.00 9.51 0.71 3.04 3.39 3.1 13.5 15.0 98 2.96 C 1520

1.5+3.5+4.2+6.0 0.89 2.07 2.49 3.55 --- 3.64 9.00 10.47 0.71 2.82 4.17 3.1 12.5 18.5 98 3.19 B 1410

1.5+3.5+5.0+5.0 0.90 2.10 3.00 3.00 --- 3.61 9.00 10.26 0.71 2.92 4.19 3.1 13.0 18.6 98 3.08 B 1460

1.5+4.2+4.2+4.2 0.96 2.68 2.68 2.68 --- 3.48 9.00 9.34 0.71 3.16 3.37 3.1 14.0 15.0 98 2.85 C 1580

1.5+4.2+4.2+5.0 0.91 2.54 2.54 3.02 --- 3.60 9.00 10.09 0.71 3.04 4.15 3.1 13.5 18.4 98 2.96 C 1520

2.0+2.0+2.0+2.0 1.86 1.86 1.86 1.86 --- 2.58 7.44 7.96 0.54 2.04 2.32 2.4 9.1 10.3 98 3.65 A 1020

2.0+2.0+2.0+2.5 1.79 1.79 1.79 2.22 --- 2.66 7.59 8.25 0.54 2.09 2.50 2.4 9.3 11.1 98 3.63 A 1045

2.0+2.0+2.0+3.5 1.67 1.67 1.67 2.93 --- 2.80 7.94 8.78 0.58 2.32 2.82 2.6 10.3 12.5 98 3.42 A 1160

2.0+2.0+2.0+4.2 1.61 1.61 1.61 3.36 --- 2.91 8.19 9.12 0.61 2.63 3.22 2.7 11.7 14.3 98 3.11 B 1315

2.0+2.0+2.0+5.0 1.54 1.54 1.54 3.85 --- 3.02 8.47 9.30 0.61 2.71 3.25 2.7 12.0 14.4 98 3.13 B 1355

2.0+2.0+2.0+6.0 1.47 1.47 1.47 4.41 --- 3.17 8.82 9.81 0.65 2.68 3.38 2.9 11.9 15.0 98 3.29 A 1340

2.0+2.0+2.0+7.1 1.37 1.37 1.37 4.89 --- 3.33 9.00 9.96 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

2.0+2.0+2.5+2.5 1.73 1.73 2.16 2.16 --- 2.73 7.78 8.53 0.58 2.21 2.69 2.6 9.8 11.9 98 3.52 A 1105

2.0+2.0+2.5+3.5 1.62 1.62 2.03 2.85 --- 2.88 8.12 9.03 0.58 2.56 3.22 2.6 11.4 14.3 98 3.17 B 1280

2.0+2.0+2.5+4.2 1.56 1.56 1.96 3.29 --- 2.98 8.37 9.13 0.61 2.69 3.22 2.7 11.9 14.3 98 3.11 B 1345

2.0+2.0+2.5+5.0 1.50 1.50 1.88 3.77 --- 3.10 8.65 9.49 0.64 2.84 3.39 2.8 12.6 15.0 98 3.05 B 1420

2.0+2.0+2.5+6.0 1.44 1.44 1.80 4.32 --- 3.24 9.00 9.94 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

2.0+2.0+2.5+7.1 1.32 1.32 1.65 4.71 --- 3.41 9.00 9.96 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.0+2.0+3.5+3.5 1.54 1.54 2.70 2.70 --- 3.02 8.48 9.13 0.61 2.82 3.22 2.7 12.5 14.3 98 3.01 B 1410

2.0+2.0+3.5+4.2 1.49 1.49 2.61 3.13 --- 3.13 8.72 9.32 0.64 2.95 3.36 2.8 13.1 14.9 98 2.96 C 1475

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

112

5MXS-E

GC_pre2_lowres.pdf 112 30/11/2011 12:31:10

Page 115: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

2.0+2.0+3.5+5.0 1.44 1.44 2.52 3.60 --- 3.24 9.00 9.49 0.64 3.04 3.39 2.8 13.5 15.0 98 2.96 C 1520

2.0+2.0+3.5+6.0 1.33 1.33 2.34 4.00 --- 3.39 9.00 9.95 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

2.0+2.0+3.5+7.1 1.23 1.23 2.16 4.38 --- 3.55 9.00 9.97 0.71 2.68 3.46 3.1 11.9 15.4 98 3.36 A 1340

2.0+2.0+4.2+4.2 1.45 1.45 3.03 3.03 --- 3.23 8.96 9.33 0.64 3.09 3.36 2.8 13.7 14.9 98 2.90 C 1545

2.0+2.0+4.2+5.0 1.36 1.36 2.87 3.41 --- 3.35 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

2.0+2.0+4.2+6.0 1.27 1.27 2.66 3.80 --- 3.49 9.00 9.96 0.68 2.81 3.46 3.0 12.5 15.4 98 3.20 A 1405

2.0+2.0+4.2+7.1 1.18 1.18 2.47 4.17 --- 3.66 9.00 10.47 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+2.0+5.0+5.0 1.29 1.29 3.21 3.21 --- 3.46 9.00 9.68 0.68 2.92 3.42 3.0 13.0 15.2 98 3.08 B 1460

2.0+2.0+5.0+6.0 1.20 1.20 3.00 3.60 --- 3.61 9.00 10.45 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

2.0+2.5+2.5+2.5 1.67 2.09 2.09 2.09 --- 2.80 7.94 8.78 0.58 2.32 2.82 2.6 10.3 12.5 98 3.42 A 1160

2.0+2.5+2.5+3.5 1.57 1.98 1.98 2.77 --- 2.95 8.30 9.12 0.61 2.69 3.22 2.7 11.9 14.3 98 3.09 B 1345

2.0+2.5+2.5+4.2 1.53 1.91 1.91 3.19 --- 3.05 8.54 9.31 0.61 2.82 3.36 2.7 12.5 14.9 98 3.03 B 1410

2.0+2.5+2.5+5.0 1.46 1.84 1.84 3.68 --- 3.17 8.82 9.49 0.64 2.90 3.39 2.8 12.9 15.0 98 3.04 B 1450

2.0+2.5+2.5+6.0 1.39 1.73 1.73 4.15 --- 3.32 9.00 9.94 0.65 2.75 3.46 2.9 12.2 15.4 98 3.27 A 1375

2.0+2.5+2.5+7.1 1.27 1.60 1.60 4.53 --- 3.48 9.00 9.96 0.68 2.68 3.46 3.0 11.9 15.4 98 3.36 A 1340

2.0+2.5+3.5+3.5 1.50 1.89 2.63 2.63 --- 3.10 8.65 9.31 0.64 2.88 3.36 2.8 12.8 14.9 98 3.00 B 1440

2.0+2.5+3.5+4.2 1.46 1.82 2.55 3.06 --- 3.20 8.89 9.32 0.64 3.08 3.36 2.8 13.7 14.9 98 2.89 C 1540

2.0+2.5+3.5+5.0 1.39 1.73 2.42 3.46 --- 3.32 9.00 9.49 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

2.0+2.5+3.5+6.0 1.28 1.61 2.25 3.86 --- 3.46 9.00 9.95 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

2.0+2.5+3.5+7.1 1.19 1.49 2.09 4.23 --- 3.63 9.00 10.42 0.71 2.68 4.01 3.1 11.9 17.8 98 3.36 A 1340

2.0+2.5+4.2+4.2 1.40 1.74 2.93 2.93 --- 3.30 9.00 9.33 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.0+2.5+4.2+5.0 1.32 1.64 2.76 3.28 --- 3.42 9.00 9.50 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

2.0+2.5+4.2+6.0 1.23 1.53 2.57 3.67 --- 3.57 9.00 10.41 0.71 2.81 4.00 3.1 12.5 17.7 98 3.20 A 1405

2.0+2.5+5.0+5.0 1.25 1.55 3.10 3.10 --- 3.54 9.00 9.68 0.71 2.92 3.42 3.1 13.0 15.2 98 3.08 B 1460

2.0+2.5+5.0+6.0 1.17 1.45 2.90 3.48 --- 3.69 9.00 10.49 0.71 2.70 3.96 3.1 12.0 17.6 98 3.33 A 1350

2.0+3.5+3.5+3.5 1.44 2.52 2.52 2.52 --- 3.24 9.00 9.32 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.0+3.5+3.5+4.2 1.36 2.39 2.39 2.86 --- 3.35 9.00 9.33 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.0+3.5+3.5+5.0 1.29 2.25 2.25 3.21 --- 3.46 9.00 9.50 0.71 3.04 3.39 3.1 13.5 15.0 98 2.96 C 1520

2.0+3.5+3.5+6.0 1.20 2.10 2.10 3.60 --- 3.61 9.00 10.40 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+3.5+4.2+4.2 1.29 2.27 2.72 2.72 --- 3.45 9.00 9.33 0.71 3.16 3.37 3.1 14.0 15.0 98 2.85 C 1580

2.0+3.5+4.2+5.0 1.23 2.14 2.57 3.06 --- 3.57 9.00 10.00 0.71 3.04 3.99 3.1 13.5 17.7 98 2.96 C 1520

2.0+3.5+5.0+5.0 1.17 2.03 2.90 2.90 --- 3.69 9.00 10.26 0.75 2.92 4.19 3.3 13.0 18.6 98 3.08 B 1460

2.0+4.2+4.2+4.2 1.23 2.59 2.59 2.59 --- 3.55 9.00 9.34 0.71 3.16 3.37 3.1 14.0 15.0 98 2.85 C 1580

2.0+4.2+4.2+5.0 1.18 2.45 2.45 2.92 --- 3.67 9.00 10.01 0.75 3.04 3.99 3.3 13.5 17.7 98 2.96 C 1520

2.5+2.5+2.5+2.5 2.03 2.03 2.03 2.03 --- 2.88 8.12 9.03 0.58 2.56 3.22 2.6 11.4 14.3 98 3.17 B 1280

2.5+2.5+2.5+3.5 1.93 1.93 1.93 2.68 --- 3.02 8.47 9.12 0.61 2.82 3.22 2.7 12.5 14.3 98 3.00 B 1410

2.5+2.5+2.5+4.2 1.87 1.86 1.86 3.13 --- 3.13 8.72 9.31 0.64 2.95 3.36 2.8 13.1 14.9 98 2.96 C 1475

2.5+2.5+2.5+5.0 1.80 1.80 1.80 3.60 --- 3.24 9.00 9.49 0.64 3.04 3.39 2.8 13.5 15.0 98 2.96 C 1520

2.5+2.5+2.5+6.0 1.67 1.67 1.67 3.99 --- 3.39 9.00 9.94 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

2.5+2.5+2.5+7.1 1.54 1.54 1.54 4.38 --- 3.55 9.00 9.96 0.71 2.68 3.46 3.1 11.9 15.4 98 3.36 A 1340

2.5+2.5+3.5+3.5 1.84 1.84 2.57 2.57 --- 3.17 8.82 9.31 0.64 3.02 3.36 2.8 13.4 14.9 98 2.92 C 1510

2.5+2.5+3.5+4.2 1.77 1.77 2.48 2.98 --- 3.27 9.00 9.32 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.5+2.5+3.5+5.0 1.67 1.67 2.33 3.33 --- 3.39 9.00 9.49 0.68 3.04 3.39 3.0 13.5 15.0 98 2.96 C 1520

2.5+2.5+3.5+6.0 1.55 1.55 2.18 3.72 --- 3.54 9.00 9.95 0.71 2.75 3.46 3.1 12.2 15.4 98 3.27 A 1375

2.5+2.5+3.5+7.1 1.44 1.44 2.02 4.10 --- 3.70 9.00 10.42 0.71 2.68 4.01 3.1 11.9 17.8 98 3.36 A 1340

2.5+2.5+4.2+4.2 1.68 1.68 2.82 2.82 --- 3.38 9.00 9.33 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.5+2.5+4.2+5.0 1.58 1.58 2.67 3.17 --- 3.49 9.00 9.50 0.71 3.04 3.39 3.1 13.5 15.0 98 2.96 C 1520

2.5+2.5+4.2+6.0 1.48 1.48 2.49 3.55 --- 3.64 9.00 10.47 0.71 2.81 4.00 3.1 12.5 17.7 98 3.20 A 1405

2.5+2.5+5.0+5.0 1.50 1.50 3.00 3.00 --- 3.61 9.00 10.25 0.71 2.92 4.18 3.1 13.0 18.5 98 3.08 B 1460

2.5+3.5+3.5+3.5 1.74 2.42 2.42 2.42 --- 3.32 9.00 9.34 0.68 3.15 3.36 3.0 14.0 14.9 98 2.86 C 1575

2.5+3.5+3.5+4.2 1.64 2.30 2.30 2.76 --- 3.42 9.00 9.33 0.71 3.15 3.36 3.1 14.0 14.9 98 2.86 C 1575

2.5+3.5+3.5+5.0 1.56 2.17 2.17 3.10 --- 3.54 9.00 9.50 0.71 3.04 3.39 3.1 13.5 15.0 98 2.96 C 1520

2.5+3.5+3.5+6.0 1.46 2.03 2.03 3.48 --- 3.69 9.00 10.40 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.5+3.5+4.2+4.2 1.56 2.18 2.63 2.63 --- 3.52 9.00 9.33 0.71 3.16 3.37 3.1 14.0 15.0 98 2.85 C 1580

2.5+3.5+4.2+5.0 1.48 2.07 2.49 2.96 --- 3.64 9.00 10.00 0.75 3.04 3.99 3.3 13.5 17.7 98 2.96 C 1520

2.5+4.2+4.2+4.2 1.50 2.50 2.50 2.50 --- 3.63 9.00 9.83 0.75 3.16 3.95 3.3 14.0 17.5 98 2.85 C 1580

3.5+3.5+3.5+3.5 2.25 2.25 2.25 2.25 --- 3.46 9.00 9.32 0.71 3.15 3.36 3.1 14.0 14.9 98 2.86 C 1575

3.5+3.5+3.5+4.2 2.14 2.14 2.14 2.58 --- 3.57 9.00 9.82 0.75 3.16 3.95 3.3 14.0 17.5 98 2.85 C 1580

3.5+3.5+3.5+5.0 2.03 2.03 2.03 2.91 --- 3.69 9.00 9.95 0.75 3.04 3.91 3.3 13.5 17.3 98 2.96 C 1520

3.5+3.5+4.2+4.2 2.05 2.05 2.45 2.45 --- 3.67 9.00 9.83 0.75 3.16 3.95 3.3 14.0 17.5 98 2.85 C 1580

1.5+1.5+1.5+1.5+1.5 1.45 1.45 1.45 1.45 1.45 2.51 7.24 7.64 0.52 1.79 2.01 2.3 7.9 8.9 98 4.04 A 895

1.5+1.5+1.5+1.5+2.0 1.39 1.39 1.39 1.39 1.86 2.58 7.42 7.96 0.52 1.90 2.18 2.3 8.4 9.7 98 3.91 A 950

1.5+1.5+1.5+1.5+2.5 1.34 1.34 1.34 1.34 2.23 2.66 7.59 8.25 0.55 2.01 2.36 2.4 8.9 10.5 98 3.78 A 1005

1.5+1.5+1.5+1.5+3.5 1.25 1.25 1.25 1.25 2.93 2.80 7.94 8.78 0.58 2.18 2.68 2.6 9.7 11.9 98 3.64 A 1090

1.5+1.5+1.5+1.5+4.2 1.20 1.20 1.20 1.20 3.37 2.91 8.19 9.12 0.58 2.30 2.88 2.6 10.2 12.8 98 3.56 A 1150

1.5+1.5+1.5+1.5+5.0 1.16 1.16 1.16 1.16 3.85 3.02 8.47 9.45 0.61 2.37 2.97 2.7 10.5 13.2 98 3.57 A 1185

1.5+1.5+1.5+1.5+6.0 1.10 1.10 1.10 1.10 4.41 3.17 8.82 9.81 0.62 2.40 3.02 2.8 10.6 13.4 98 3.68 A 1200

1.5+1.5+1.5+1.5+7.1 1.03 1.03 1.03 1.03 4.88 3.33 9.00 10.12 0.65 2.47 3.17 2.9 11.0 14.1 98 3.64 A 1235

1.5+1.5+1.5+2.0+2.0 1.34 1.34 1.34 1.79 1.79 2.66 7.59 8.25 0.55 2.01 2.36 2.4 8.9 10.5 98 3.78 A 1005

1.5+1.5+1.5+2.0+2.5 1.30 1.30 1.30 1.73 2.16 2.73 7.77 8.53 0.55 2.06 2.49 2.4 9.1 11.0 98 3.77 A 1030

1.5+1.5+1.5+2.0+3.5 1.22 1.22 1.22 1.62 2.84 2.88 8.12 9.03 0.58 2.24 2.81 2.6 9.9 12.5 98 3.63 A 1120

1.5+1.5+1.5+2.0+4.2 1.17 1.17 1.17 1.56 3.29 2.98 8.37 9.33 0.58 2.42 3.02 2.6 10.7 13.4 98 3.46 A 1210

1.5+1.5+1.5+2.0+5.0 1.13 1.13 1.13 1.50 3.76 3.10 8.65 9.64 0.61 2.50 3.12 2.7 11.1 13.8 98 3.46 A 1250

1.5+1.5+1.5+2.0+6.0 1.08 1.08 1.08 1.44 4.32 3.24 9.00 9.96 0.62 2.46 3.09 2.8 10.9 13.7 98 3.66 A 1230

1.5+1.5+1.5+2.0+7.1 0.99 0.99 0.99 1.32 4.70 3.41 9.00 10.23 0.65 2.47 3.33 2.9 11.0 14.8 98 3.64 A 1235

1.5+1.5+1.5+2.5+2.5 1.25 1.25 1.25 2.09 2.09 2.80 7.94 8.78 0.58 2.18 2.68 2.6 9.7 11.9 98 3.64 A 1090

1.5+1.5+1.5+2.5+3.5 1.19 1.19 1.19 1.98 2.77 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

1.5+1.5+1.5+2.5+4.2 1.14 1.14 1.14 1.91 3.20 3.05 8.54 9.53 0.61 2.49 3.17 2.7 11.0 14.1 98 3.43 A 1245

1.5+1.5+1.5+2.5+5.0 1.10 1.10 1.10 1.84 3.68 3.17 8.82 9.81 0.61 2.56 3.26 2.7 11.4 14.5 98 3.45 A 1280

1.5+1.5+1.5+2.5+6.0 1.04 1.04 1.04 1.73 4.15 3.32 9.00 10.09 0.65 2.46 3.17 2.9 10.9 14.1 98 3.66 A 1230

1.5+1.5+1.5+2.5+7.1 0.96 0.96 0.96 1.60 4.53 3.48 9.00 10.32 0.65 2.47 3.33 2.9 11.0 14.8 98 3.64 A 1235

1.5+1.5+1.5+3.5+3.5 1.13 1.13 1.13 2.63 2.63 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

1.5+1.5+1.5+3.5+4.2 1.09 1.09 1.09 2.55 3.06 3.20 8.89 9.87 0.65 2.68 3.39 2.9 11.9 15.0 98 3.32 A 1340

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

113

5MXS-E

GC_pre2_lowres.pdf 113 30/11/2011 12:31:10

Page 116: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+1.5+1.5+3.5+5.0 1.04 1.04 1.04 2.42 3.46 3.32 9.00 10.09 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

1.5+1.5+1.5+3.5+6.0 0.96 0.96 0.96 2.25 3.86 3.46 9.00 10.31 0.65 2.46 3.32 2.9 10.9 14.7 98 3.66 A 1230

1.5+1.5+1.5+3.5+7.1 0.89 0.89 0.89 2.09 4.23 3.63 9.00 10.46 0.68 2.47 3.48 3.0 11.0 15.4 98 3.64 A 1235

1.5+1.5+1.5+4.2+4.2 1.05 1.05 1.05 2.93 2.93 3.30 9.00 9.99 0.65 2.75 3.47 2.9 12.2 15.4 98 3.27 A 1375

1.5+1.5+1.5+4.2+5.0 0.99 0.99 0.99 2.76 3.28 3.42 9.00 10.16 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+1.5+1.5+4.2+6.0 0.92 0.92 0.92 2.57 3.67 3.57 9.00 10.41 0.68 2.47 3.40 3.0 11.0 15.1 98 3.64 A 1235

1.5+1.5+1.5+5.0+5.0 0.93 0.93 0.93 3.10 3.10 3.54 9.00 10.34 0.68 2.58 3.52 3.0 11.4 15.6 98 3.49 A 1290

1.5+1.5+1.5+5.0+6.0 0.87 0.87 0.87 2.90 3.48 3.69 9.00 10.49 0.68 2.41 3.35 3.0 10.7 14.9 98 3.73 A 1205

1.5+1.5+2.0+2.0+2.0 1.30 1.30 1.73 1.73 1.73 2.73 7.77 8.53 0.55 2.06 2.49 2.4 9.1 11.0 98 3.77 A 1030

1.5+1.5+2.0+2.0+2.5 1.25 1.25 1.67 1.67 2.09 2.80 7.94 8.78 0.58 2.18 2.68 2.6 9.7 11.9 98 3.64 A 1090

1.5+1.5+2.0+2.0+3.5 1.19 1.19 1.58 1.58 2.77 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

1.5+1.5+2.0+2.0+4.2 1.14 1.14 1.53 1.53 3.20 3.05 8.54 9.53 0.61 2.49 3.17 2.7 11.0 14.1 98 3.43 A 1245

1.5+1.5+2.0+2.0+5.0 1.10 1.10 1.47 1.47 3.68 3.17 8.82 9.81 0.61 2.56 3.26 2.7 11.4 14.5 98 3.45 A 1280

1.5+1.5+2.0+2.0+6.0 1.04 1.04 1.38 1.38 4.15 3.32 9.00 10.09 0.65 2.46 3.17 2.9 10.9 14.1 98 3.66 A 1230

1.5+1.5+2.0+2.0+7.1 0.96 0.96 1.28 1.28 4.53 3.48 9.00 10.32 0.65 2.47 3.33 2.9 11.0 14.8 98 3.64 A 1235

1.5+1.5+2.0+2.5+2.5 1.22 1.22 1.62 2.03 2.03 2.88 8.12 9.03 0.58 2.24 2.81 2.6 9.9 12.5 98 3.63 A 1120

1.5+1.5+2.0+2.5+3.5 1.16 1.16 1.54 1.93 2.70 3.02 8.47 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

1.5+1.5+2.0+2.5+4.2 1.12 1.12 1.49 1.86 3.13 3.13 8.72 9.71 0.61 2.62 3.31 2.7 11.6 14.7 98 3.33 A 1310

1.5+1.5+2.0+2.5+5.0 1.08 1.08 1.44 1.80 3.60 3.24 9.00 9.96 0.65 2.70 3.41 2.9 12.0 15.1 98 3.33 A 1350

1.5+1.5+2.0+2.5+6.0 1.00 1.00 1.33 1.67 4.00 3.39 9.00 10.21 0.65 2.46 3.32 2.9 10.9 14.7 98 3.66 A 1230

1.5+1.5+2.0+2.5+7.1 0.92 0.92 1.23 1.54 4.38 3.55 9.00 10.40 0.68 2.47 3.40 3.0 11.0 15.1 98 3.64 A 1235

1.5+1.5+2.0+3.5+3.5 1.10 1.10 1.47 2.57 2.57 3.17 8.82 9.81 0.61 2.68 3.39 2.7 11.9 15.0 98 3.29 A 1340

1.5+1.5+2.0+3.5+4.2 1.06 1.06 1.42 2.48 2.98 3.27 9.00 9.98 0.65 2.75 3.46 2.9 12.2 15.4 98 3.27 A 1375

1.5+1.5+2.0+3.5+5.0 1.00 1.00 1.33 2.33 3.33 3.39 9.00 10.16 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

1.5+1.5+2.0+3.5+6.0 0.93 0.93 1.24 2.17 3.72 3.54 9.00 10.38 0.68 2.46 3.40 3.0 10.9 15.1 98 3.66 A 1230

1.5+1.5+2.0+3.5+7.1 0.87 0.87 1.15 2.02 4.10 3.70 9.00 10.50 0.71 2.47 3.48 3.1 11.0 15.4 98 3.64 A 1235

1.5+1.5+2.0+4.2+4.2 1.01 1.01 1.34 2.82 2.82 3.38 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

1.5+1.5+2.0+4.2+5.0 0.95 0.95 1.27 2.66 3.17 3.49 9.00 10.16 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+1.5+2.0+4.2+6.0 0.89 0.89 1.18 2.49 3.55 3.64 9.00 10.47 0.68 2.47 3.48 3.0 11.0 15.4 98 3.64 A 1235

1.5+1.5+2.0+5.0+5.0 0.90 0.90 1.20 3.00 3.00 3.61 9.00 10.45 0.68 2.58 3.68 3.0 11.4 16.3 98 3.49 A 1290

1.5+1.5+2.5+2.5+2.5 1.19 1.19 1.98 1.98 1.98 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

1.5+1.5+2.5+2.5+3.5 1.13 1.13 1.88 1.88 2.63 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

1.5+1.5+2.5+2.5+4.2 1.09 1.09 1.82 1.82 3.06 3.20 8.89 9.87 0.65 2.68 3.39 2.9 11.9 15.0 98 3.32 A 1340

1.5+1.5+2.5+2.5+5.0 1.04 1.04 1.73 1.73 3.46 3.32 9.00 10.09 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

1.5+1.5+2.5+2.5+6.0 0.96 0.96 1.61 1.61 3.86 3.46 9.00 10.31 0.65 2.46 3.40 2.9 10.9 15.1 98 3.66 A 1230

1.5+1.5+2.5+2.5+7.1 0.89 0.89 1.49 1.49 4.23 3.63 9.00 10.46 0.68 2.47 3.48 3.0 11.0 15.4 98 3.64 A 1235

1.5+1.5+2.5+3.5+3.5 1.08 1.08 1.80 2.52 2.52 3.24 9.00 9.96 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

1.5+1.5+2.5+3.5+4.2 1.02 1.02 1.70 2.39 2.86 3.35 9.00 9.98 0.65 2.75 3.46 2.9 12.2 15.4 98 3.27 A 1375

1.5+1.5+2.5+3.5+5.0 0.96 0.96 1.61 2.25 3.21 3.46 9.00 10.16 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+1.5+2.5+3.5+6.0 0.90 0.90 1.50 2.10 3.60 3.61 9.00 10.45 0.68 2.46 3.48 3.0 10.9 15.4 98 3.66 A 1230

1.5+1.5+2.5+4.2+4.2 0.97 0.97 1.62 2.72 2.72 3.45 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

1.5+1.5+2.5+4.2+5.0 0.92 0.92 1.53 2.57 3.06 3.57 9.00 10.41 0.68 2.70 3.81 3.0 12.0 16.9 98 3.33 A 1350

1.5+1.5+2.5+5.0+5.0 0.87 0.87 1.45 2.90 2.90 3.69 9.00 10.49 0.71 2.58 3.68 3.1 11.4 16.3 98 3.49 A 1290

1.5+1.5+3.5+3.5+3.5 1.00 1.00 2.33 2.33 2.33 3.39 9.00 9.98 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

1.5+1.5+3.5+3.5+4.2 0.95 0.95 2.22 2.22 2.66 3.49 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

1.5+1.5+3.5+3.5+5.0 0.90 0.90 2.10 2.10 3.00 3.61 9.00 10.45 0.71 2.70 3.80 3.1 12.0 16.9 98 3.33 A 1350

1.5+1.5+3.5+4.2+4.2 0.91 0.91 2.11 2.54 2.54 3.60 9.00 10.44 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

1.5+2.0+2.0+2.0+2.0 1.25 1.67 1.67 1.67 1.67 2.80 7.94 8.78 0.58 2.18 2.68 2.6 9.7 11.9 98 3.64 A 1090

1.5+2.0+2.0+2.0+2.5 1.22 1.62 1.62 1.62 2.03 2.88 8.12 9.03 0.58 2.24 2.81 2.6 9.9 12.5 98 3.63 A 1120

1.5+2.0+2.0+2.0+3.5 1.16 1.54 1.54 1.54 2.70 3.02 8.47 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

1.5+2.0+2.0+2.0+4.2 1.12 1.49 1.49 1.49 3.13 3.13 8.72 9.71 0.61 2.62 3.31 2.7 11.6 14.7 98 3.33 A 1310

1.5+2.0+2.0+2.0+5.0 1.08 1.44 1.44 1.44 3.60 3.24 9.00 9.96 0.65 2.70 3.41 2.9 12.0 15.1 98 3.33 A 1350

1.5+2.0+2.0+2.0+6.0 1.00 1.33 1.33 1.33 4.00 3.39 9.00 10.21 0.65 2.46 3.32 2.9 10.9 14.7 98 3.66 A 1230

1.5+2.0+2.0+2.0+7.1 0.92 1.23 1.23 1.23 4.38 3.55 9.00 10.40 0.68 2.47 3.40 3.0 11.0 15.1 98 3.64 A 1235

1.5+2.0+2.0+2.5+2.5 1.19 1.58 1.58 1.98 1.98 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

1.5+2.0+2.0+2.5+3.5 1.13 1.50 1.50 1.88 2.63 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

1.5+2.0+2.0+2.5+4.2 1.09 1.46 1.46 1.82 3.06 3.20 8.89 9.87 0.65 2.68 3.39 2.9 11.9 15.0 98 3.32 A 1340

1.5+2.0+2.0+2.5+5.0 1.04 1.38 1.38 1.73 3.46 3.32 9.00 10.09 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

1.5+2.0+2.0+2.5+6.0 0.96 1.29 1.29 1.61 3.86 3.46 9.00 10.31 0.65 2.46 3.40 2.9 10.9 15.1 98 3.66 A 1230

1.5+2.0+2.0+2.5+7.1 0.89 1.19 1.19 1.49 4.23 3.63 9.00 10.46 0.68 2.47 3.48 3.0 11.0 15.4 98 3.64 A 1235

1.5+2.0+2.0+3.5+3.5 1.08 1.44 1.44 2.52 2.52 3.24 9.00 9.96 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

1.5+2.0+2.0+3.5+4.2 1.02 1.36 1.36 2.39 2.86 3.35 9.00 9.98 0.65 2.75 3.46 2.9 12.2 15.4 98 3.27 A 1375

1.5+2.0+2.0+3.5+5.0 0.96 1.29 1.29 2.25 3.21 3.46 9.00 10.16 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+2.0+2.0+3.5+6.0 0.90 1.20 1.20 2.10 3.60 3.61 9.00 10.45 0.68 2.46 3.48 3.0 10.9 15.4 98 3.66 A 1230

1.5+2.0+2.0+4.2+4.2 0.97 1.29 1.29 2.72 2.72 3.45 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

1.5+2.0+2.0+4.2+5.0 0.92 1.22 1.22 2.57 3.06 3.57 9.00 10.41 0.68 2.70 3.81 3.0 12.0 16.9 98 3.33 A 1350

1.5+2.0+2.0+5.0+5.0 0.87 1.16 1.16 2.90 2.90 3.69 9.00 10.49 0.71 2.58 3.68 3.1 11.4 16.3 98 3.49 A 1290

1.5+2.0+2.5+2.5+2.5 1.16 1.54 1.93 1.93 1.93 3.02 8.47 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

1.5+2.0+2.5+2.5+3.5 1.10 1.47 1.84 1.84 2.57 3.17 8.82 9.81 0.61 2.68 3.39 2.7 11.9 15.0 98 3.29 A 1340

1.5+2.0+2.5+2.5+4.2 1.06 1.42 1.77 1.77 2.98 3.27 9.00 9.97 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

1.5+2.0+2.5+2.5+5.0 1.00 1.33 1.67 1.67 3.33 3.39 9.00 10.15 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

1.5+2.0+2.5+2.5+6.0 0.93 1.24 1.55 1.55 3.72 3.54 9.00 10.38 0.68 2.46 3.40 3.0 10.9 15.1 98 3.66 A 1230

1.5+2.0+2.5+2.5+7.1 0.87 1.15 1.44 1.44 4.10 3.70 9.00 10.50 0.71 2.47 3.48 3.1 11.0 15.4 98 3.64 A 1235

1.5+2.0+2.5+3.5+3.5 1.04 1.38 1.73 2.42 2.42 3.32 9.00 9.97 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

1.5+2.0+2.5+3.5+4.2 0.99 1.31 1.64 2.30 2.76 3.42 9.00 9.98 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

1.5+2.0+2.5+3.5+5.0 0.93 1.24 1.55 2.17 3.10 3.54 9.00 10.16 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+2.0+2.5+3.5+6.0 0.87 1.16 1.45 2.03 3.48 3.69 9.00 10.49 0.71 2.46 3.48 3.1 10.9 15.4 98 3.66 A 1230

1.5+2.0+2.5+4.2+4.2 0.94 1.25 1.56 2.63 2.63 3.52 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

1.5+2.0+2.5+4.2+5.0 0.89 1.18 1.48 2.49 2.96 3.64 9.00 10.47 0.71 2.70 3.89 3.1 12.0 17.3 98 3.33 A 1350

1.5+2.0+3.5+3.5+3.5 0.96 1.29 2.25 2.25 2.25 3.46 9.00 9.98 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

1.5+2.0+3.5+3.5+4.2 0.92 1.22 2.14 2.14 2.57 3.57 9.00 10.41 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

1.5+2.0+3.5+3.5+5.0 0.87 1.16 2.03 2.03 2.90 3.69 9.00 10.49 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

1.5+2.0+3.5+4.2+4.2 0.88 1.17 2.05 2.45 2.45 3.67 9.00 10.48 0.71 2.75 4.09 3.1 12.2 18.1 98 3.27 A 1375

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

114

5MXS-E

GC_pre2_lowres.pdf 114 30/11/2011 12:31:11

Page 117: DAIKIN General Catalogue 2012

Combination tables

COOLINGOUTDOOR

UNITINDOOR

UNIT

COOLING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)EER

ENERGY LABEL

AEC (kWh)A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+2.5+2.5+2.5+2.5 1.13 1.88 1.88 1.88 1.88 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

1.5+2.5+2.5+2.5+3.5 1.08 1.80 1.80 1.80 2.52 3.24 9.00 9.96 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

1.5+2.5+2.5+2.5+4.2 1.02 1.70 1.70 1.70 2.86 3.35 9.00 9.97 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

1.5+2.5+2.5+2.5+5.0 0.96 1.61 1.61 1.61 3.21 3.46 9.00 10.15 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

1.5+2.5+2.5+2.5+6.0 0.90 1.50 1.50 1.50 3.60 3.61 9.00 10.45 0.68 2.46 3.48 3.0 10.9 15.4 98 3.66 A 1230

1.5+2.5+2.5+3.5+3.5 1.00 1.67 1.67 2.33 2.33 3.39 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

1.5+2.5+2.5+3.5+4.2 0.95 1.58 1.58 2.22 2.66 3.49 9.00 9.98 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

1.5+2.5+2.5+3.5+5.0 0.90 1.50 1.50 2.10 3.00 3.61 9.00 10.45 0.71 2.70 3.80 3.1 12.0 16.9 98 3.33 A 1350

1.5+2.5+2.5+4.2+4.2 0.91 1.51 1.51 2.54 2.54 3.60 9.00 10.44 0.71 2.75 4.09 3.1 12.2 18.1 98 3.27 A 1375

1.5+2.5+3.5+3.5+3.5 0.93 1.55 2.17 2.17 2.17 3.54 9.00 9.98 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

1.5+2.5+3.5+3.5+4.2 0.89 1.48 2.07 2.07 2.49 3.64 9.00 10.47 0.71 2.75 4.09 3.1 12.2 18.1 98 3.27 A 1375

1.5+3.5+3.5+3.5+3.5 0.87 2.03 2.03 2.03 2.03 3.69 9.00 10.49 0.71 2.75 4.17 3.1 12.2 18.5 98 3.27 A 1375

2.0+2.0+2.0+2.0+2.0 1.63 1.63 1.63 1.63 1.63 2.88 8.15 9.03 0.58 2.30 2.81 2.6 10.2 12.5 98 3.54 A 1150

2.0+2.0+2.0+2.0+2.5 1.58 1.58 1.58 1.58 1.98 2.95 8.30 9.25 0.58 2.36 2.95 2.6 10.5 13.1 98 3.52 A 1180

2.0+2.0+2.0+2.0+3.5 1.50 1.50 1.50 1.50 2.65 3.10 8.65 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.39 A 1275

2.0+2.0+2.0+2.0+4.2 1.46 1.46 1.46 1.46 3.05 3.20 8.89 9.87 0.65 2.68 3.39 2.9 11.9 15.0 98 3.32 A 1340

2.0+2.0+2.0+2.0+5.0 1.38 1.38 1.38 1.38 3.48 3.32 9.00 10.09 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

2.0+2.0+2.0+2.0+6.0 1.29 1.29 1.29 1.29 3.84 3.46 9.00 10.31 0.65 2.50 3.40 2.9 11.1 15.1 98 3.60 A 1250

2.0+2.0+2.0+2.0+7.1 1.19 1.19 1.19 1.19 4.24 3.63 9.00 10.46 0.68 2.47 3.48 3.0 11.0 15.4 98 3.64 A 1235

2.0+2.0+2.0+2.5+2.5 1.54 1.54 1.54 1.92 1.92 3.02 8.46 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

2.0+2.0+2.0+2.5+3.5 1.47 1.47 1.47 1.84 2.57 3.17 8.82 9.81 0.61 2.68 3.39 2.7 11.9 15.0 98 3.29 A 1340

2.0+2.0+2.0+2.5+4.2 1.42 1.42 1.42 1.77 2.97 3.27 9.00 9.97 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

2.0+2.0+2.0+2.5+5.0 1.33 1.33 1.33 1.67 3.34 3.39 9.00 10.15 0.65 2.70 3.49 2.9 12.0 15.5 98 3.33 A 1350

2.0+2.0+2.0+2.5+6.0 1.24 1.24 1.24 1.55 3.73 3.54 9.00 10.38 0.68 2.50 3.40 3.0 11.1 15.1 98 3.60 A 1250

2.0+2.0+2.0+2.5+7.1 1.15 1.15 1.15 1.44 4.11 3.70 9.00 10.50 0.71 2.47 3.48 3.1 11.0 15.4 98 3.64 A 1235

2.0+2.0+2.0+3.5+3.5 1.54 1.54 1.54 1.92 1.92 3.02 8.46 9.45 0.61 2.49 3.09 2.7 11.0 13.7 98 3.40 A 1245

2.0+2.0+2.0+3.5+4.2 1.31 1.31 1.31 2.31 2.76 3.42 9.00 9.98 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

2.0+2.0+2.0+3.5+5.0 1.24 1.24 1.24 2.17 3.11 3.54 9.00 10.16 0.68 2.74 3.49 3.0 12.2 15.5 98 3.28 A 1370

2.0+2.0+2.0+3.5+6.0 1.16 1.16 1.16 2.03 3.49 3.69 9.00 10.49 0.71 2.46 3.48 3.1 10.9 15.4 98 3.66 A 1230

2.0+2.0+2.0+4.2+4.2 1.24 1.24 1.24 2.64 2.64 3.52 9.00 9.99 0.68 2.75 3.47 3.0 12.2 15.4 98 3.27 A 1375

2.0+2.0+2.0+4.2+5.0 1.18 1.18 1.18 2.50 2.96 3.64 9.00 10.47 0.71 2.70 3.89 3.1 12.0 17.3 98 3.33 A 1350

2.0+2.0+2.5+2.5+2.5 1.51 1.51 1.88 1.88 1.88 3.10 8.66 9.64 0.61 2.55 3.24 2.7 11.3 14.4 98 3.40 A 1275

2.0+2.0+2.5+2.5+3.5 1.44 1.44 1.80 1.80 2.52 3.24 9.00 9.96 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

2.0+2.0+2.5+2.5+4.2 1.37 1.37 1.70 1.70 2.86 3.35 9.00 9.66 0.65 2.86 3.46 2.9 12.7 15.4 98 3.15 B 1430

2.0+2.0+2.5+2.5+5.0 1.29 1.29 1.61 1.61 3.20 3.46 9.00 10.15 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

2.0+2.0+2.5+2.5+6.0 1.20 1.20 1.50 1.50 3.60 3.61 9.00 10.45 0.68 2.46 3.48 3.0 10.9 15.4 98 3.66 A 1230

2.0+2.0+2.5+3.5+3.5 1.33 1.33 1.68 2.33 2.33 3.39 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.0+2.0+2.5+3.5+4.2 1.27 1.27 1.58 2.22 2.66 3.49 9.00 9.66 0.68 2.79 3.46 3.0 12.4 15.4 98 3.23 A 1395

2.0+2.0+2.5+3.5+5.0 1.20 1.20 1.50 2.10 3.00 3.61 9.00 10.45 0.71 2.70 3.80 3.1 12.0 16.9 98 3.33 A 1350

2.0+2.0+2.5+4.2+4.2 1.21 1.21 1.50 2.54 2.54 3.60 9.00 10.44 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+2.0+3.5+3.5+3.5 1.23 1.23 2.18 2.18 2.18 3.54 9.00 9.98 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.0+2.0+3.5+3.5+4.2 1.18 1.18 2.07 2.07 2.50 3.64 9.00 10.47 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+2.5+2.5+2.5+2.5 1.46 1.84 1.84 1.84 1.84 3.17 8.82 9.81 0.61 2.68 3.39 2.7 11.9 15.0 98 3.29 A 1340

2.0+2.5+2.5+2.5+3.5 1.39 1.73 1.73 1.73 2.42 3.32 9.00 9.96 0.65 2.82 3.46 2.9 12.5 15.4 98 3.19 B 1410

2.0+2.5+2.5+2.5+4.2 1.32 1.64 1.64 1.64 2.76 3.42 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.0+2.5+2.5+2.5+5.0 1.25 1.55 1.55 1.55 3.10 3.54 9.00 10.15 0.68 2.70 3.49 3.0 12.0 15.5 98 3.33 A 1350

2.0+2.5+2.5+2.5+6.0 1.17 1.45 1.45 1.45 3.48 3.69 9.00 10.49 0.71 2.46 3.48 3.1 10.9 15.4 98 3.66 A 1230

2.0+2.5+2.5+3.5+3.5 1.28 1.61 1.61 2.25 2.25 3.46 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.0+2.5+2.5+3.5+4.2 1.23 1.53 1.53 2.14 2.57 3.57 9.00 10.41 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+2.5+2.5+3.5+5.0 1.17 1.45 1.45 2.03 2.90 3.69 9.00 10.49 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

2.0+2.5+2.5+4.2+4.2 1.18 1.46 1.46 2.45 2.45 3.64 9.00 10.47 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.0+2.5+3.5+3.5+3.5 1.20 1.50 2.10 2.10 2.10 3.61 9.00 10.42 0.71 2.82 4.01 3.1 12.5 17.8 98 3.19 B 1410

2.5+2.5+2.5+2.5+2.5 1.80 1.80 1.80 1.80 1.80 3.24 9.00 9.95 0.65 2.81 3.46 2.9 12.5 15.4 98 3.20 A 1405

2.5+2.5+2.5+2.5+3.5 1.67 1.67 1.67 1.67 2.32 3.39 9.00 9.96 0.68 2.75 3.46 3.0 12.2 15.4 98 3.27 A 1375

2.5+2.5+2.5+2.5+4.2 1.58 1.58 1.58 1.58 2.68 3.49 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.5+2.5+2.5+2.5+5.0 1.50 1.50 1.50 1.50 3.00 3.61 9.00 10.45 0.71 2.70 3.88 3.1 12.0 17.2 98 3.33 A 1350

2.5+2.5+2.5+3.5+3.5 1.56 1.56 1.56 2.16 2.16 3.54 9.00 9.97 0.68 2.82 3.46 3.0 12.5 15.4 98 3.19 B 1410

2.5+2.5+2.5+3.5+4.2 1.48 1.48 1.48 2.07 2.49 3.64 9.00 10.47 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

2.5+2.5+3.5+3.5+3.5 1.44 1.44 2.04 2.04 2.04 3.69 9.00 10.42 0.71 2.75 4.01 3.1 12.2 17.8 98 3.27 A 1375

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

115

5MXS-E

GC_pre2_lowres.pdf 115 30/11/2011 12:31:11

Page 118: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5 2.22 --- --- --- --- 1.30 2.22 3.40 0.40 0.77 1.12 1.8 3.4 5.0 98 2.88 D

2.0 2.44 --- --- --- --- 1.36 2.44 4.20 0.35 0.68 1.38 1.6 3.0 6.1 98 3.59 B

2.5 3.05 --- --- --- --- 1.42 3.05 4.65 0.37 0.90 1.48 1.6 4.0 6.6 98 3.39 C

3.5 4.27 --- --- --- --- 1.54 4.27 5.11 0.39 1.43 1.95 1.7 6.3 8.7 98 2.99 D

4.2 5.12 --- --- --- --- 1.75 5.12 5.16 0.60 1.73 1.98 2.7 7.7 8.8 98 2.96 D

5.0 6.09 --- --- --- --- 1.98 6.09 7.42 0.48 1.91 2.48 2.1 8.5 11.0 98 3.19 D

6.0 7.31 --- --- --- --- 2.28 7.31 8.53 0.60 2.30 2.89 2.7 10.2 12.8 98 3.18 D

7.1 8.65 --- --- --- --- 2.60 8.65 9.02 0.67 2.87 3.04 3.0 12.7 13.5 98 3.01 D

1.5+1.5 1.83 1.83 --- --- --- 1.48 3.66 5.75 0.39 0.91 1.48 1.7 4.0 6.6 98 4.02 A

1.5+2.0 1.83 2.44 --- --- --- 1.54 4.27 5.75 0.37 1.04 1.48 1.6 4.6 6.6 98 4.11 A

1.5+2.5 1.83 3.05 --- --- --- 1.69 4.88 7.46 0.39 1.21 2.09 1.7 5.4 9.3 98 4.03 A

1.5+3.5 1.83 4.26 --- --- --- 1.98 6.09 7.46 0.47 1.71 2.29 2.1 7.6 10.2 98 3.56 B

1.5+4.2 1.83 5.12 --- --- --- 2.19 6.95 8.53 0.45 2.09 2.81 2.0 9.3 12.5 98 3.33 C

1.5+5.0 1.83 6.09 --- --- --- 2.43 7.92 9.09 0.47 2.16 2.66 2.1 9.6 11.8 98 3.67 A

1.5+6.0 1.79 7.14 --- --- --- 2.72 8.93 9.88 0.51 2.47 2.96 2.3 11.0 13.1 98 3.62 A

1.5+7.1 1.69 8.00 --- --- --- 3.03 9.69 9.90 0.55 2.83 2.94 2.4 12.6 13.0 98 3.42 B

2.0+2.0 2.44 2.44 --- --- --- 1.69 4.88 6.85 0.39 1.21 1.87 1.7 5.4 8.3 98 4.03 A

2.0+2.5 2.44 3.05 --- --- --- 1.84 5.49 7.25 0.41 1.40 2.05 1.8 6.2 9.1 98 3.92 A

2.0+3.5 2.44 4.26 --- --- --- 2.13 6.70 7.74 0.50 1.99 2.44 2.2 8.8 10.8 98 3.37 C

2.0+4.2 2.44 5.11 --- --- --- 2.34 7.55 8.53 0.62 2.33 2.81 2.8 10.3 12.5 98 3.24 C

2.0+5.0 2.44 6.09 --- --- --- 2.57 8.53 9.09 0.63 2.45 2.66 2.8 10.9 11.8 98 3.48 B

2.0+6.0 2.32 6.95 --- --- --- 2.86 9.27 9.88 0.65 2.63 2.96 2.9 11.7 13.1 98 3.52 B

2.0+7.1 2.20 7.83 --- --- --- 3.17 10.03 10.37 0.69 3.01 3.18 3.1 13.4 14.1 98 3.33 C

2.5+2.5 3.04 3.04 --- --- --- 1.98 6.08 7.46 0.47 1.76 2.35 2.1 7.8 10.4 98 3.45 B

2.5+3.5 3.05 4.26 --- --- --- 2.28 7.31 8.53 0.60 2.34 2.94 2.7 10.4 13.0 98 3.12 D

2.5+4.2 3.04 5.12 --- --- --- 2.49 8.16 9.02 0.65 2.76 3.18 2.9 12.2 14.1 98 2.96 D

2.5+5.0 2.98 5.95 --- --- --- 2.72 8.93 9.70 0.66 2.61 2.99 2.9 11.6 13.3 98 3.42 B

2.5+6.0 2.83 6.79 --- --- --- 3.00 9.62 9.88 0.67 2.86 3.03 3.0 12.7 13.4 98 3.36 C

2.5+7.1 2.70 7.68 --- --- --- 3.31 10.38 10.77 0.72 3.22 3.46 3.2 14.3 15.4 98 3.22 C

3.5+3.5 4.27 4.27 --- --- --- 2.57 8.54 9.02 0.65 2.91 3.15 2.9 12.9 14.0 98 2.93 D

3.5+4.2 4.12 4.94 --- --- --- 2.77 9.06 9.60 0.70 3.21 3.53 3.1 14.2 15.7 98 2.82 D

3.5+5.0 3.96 5.66 --- --- --- 3.00 9.62 9.70 0.71 2.93 2.98 3.1 13.0 13.2 98 3.28 C

3.5+6.0 3.80 6.51 --- --- --- 3.28 10.31 10.75 0.72 3.19 3.43 3.2 14.2 15.2 98 3.23 C

3.5+7.1 3.43 6.97 --- --- --- 3.59 10.40 10.78 0.77 3.11 3.35 3.4 13.8 14.9 98 3.34 C

4.2+4.2 4.77 4.77 --- --- --- 2.97 9.54 9.61 0.72 3.47 3.53 3.2 15.4 15.7 98 2.75 E

4.2+5.0 4.61 5.49 --- --- --- 3.20 10.10 10.12 0.73 3.22 3.28 3.2 14.3 14.6 98 3.14 D

4.2+6.0 4.28 6.12 --- --- --- 3.48 10.40 10.76 0.75 3.24 3.42 3.3 14.4 15.2 98 3.21 C

4.2+7.1 3.87 6.53 --- --- --- 3.79 10.40 10.78 0.79 3.11 3.34 3.5 13.8 14.8 98 3.34 C

5.0+5.0 5.20 5.20 --- --- --- 3.42 10.40 10.64 0.76 3.28 3.40 3.4 14.6 15.1 98 3.17 D

5.0+6.0 4.73 5.67 --- --- --- 3.70 10.40 10.88 0.75 3.08 3.31 3.3 13.7 14.7 98 3.38 C

5.0+7.1 4.30 6.10 --- --- --- 4.01 10.40 10.51 0.83 3.01 3.06 3.7 13.4 13.6 98 3.46 B

6.0+6.0 5.20 5.20 --- --- --- 3.99 10.40 10.71 0.76 2.88 3.04 3.4 12.8 13.5 98 3.61 A

6.0+7.1 4.76 5.64 --- --- --- 4.30 10.40 10.74 0.84 2.86 3.03 3.7 12.7 13.4 98 3.64 A

7.1+7.1 5.20 5.20 --- --- --- 4.61 10.40 10.77 0.89 2.85 3.02 3.9 12.6 13.4 98 3.65 A

1.5+1.5+1.5 1.83 1.83 1.83 --- --- 1.84 5.50 7.52 0.47 1.24 1.92 2.1 5.5 8.5 98 4.44 A

1.5+1.5+2.0 1.83 1.83 2.44 --- --- 1.98 6.10 7.52 0.49 1.39 1.92 2.2 6.2 8.5 98 4.39 A

1.5+1.5+2.5 1.83 1.83 3.05 --- --- 2.13 6.71 7.52 0.51 1.63 1.92 2.3 7.2 8.5 98 4.12 A

1.5+1.5+3.5 1.83 1.83 4.27 --- --- 2.43 7.93 9.22 0.55 2.04 2.57 2.4 9.1 11.4 98 3.89 A

1.5+1.5+4.2 1.82 1.82 5.09 --- --- 2.63 8.73 9.22 0.60 2.37 2.57 2.7 10.5 11.4 98 3.68 A

1.5+1.5+5.0 1.74 1.74 5.80 --- --- 2.86 9.28 9.99 0.60 2.53 2.84 2.7 11.2 12.6 98 3.67 A

1.5+1.5+6.0 1.66 1.66 6.65 --- --- 3.14 9.97 10.71 0.61 2.65 3.04 2.7 11.8 13.5 98 3.76 A

1.5+1.5+7.1 1.55 1.55 7.32 --- --- 3.45 10.41 10.75 0.65 2.86 3.03 2.9 12.7 13.4 98 3.64 A

1.5+2.0+2.0 1.83 2.44 2.44 --- --- 2.13 6.71 7.52 0.51 1.63 1.92 2.3 7.2 8.5 98 4.12 A

1.5+2.0+2.5 1.83 2.44 3.05 --- --- 2.28 7.32 8.67 0.53 1.83 2.32 2.4 8.1 10.3 98 4.00 A

1.5+2.0+3.5 1.83 2.44 4.27 --- --- 2.58 8.54 9.22 0.57 2.27 2.57 2.5 10.1 11.4 98 3.76 A

1.5+2.0+4.2 1.77 2.36 4.95 --- --- 2.77 9.07 9.89 0.62 2.47 2.89 2.8 11.0 12.8 98 3.67 A

1.5+2.0+5.0 1.70 2.27 5.66 --- --- 3.00 9.63 9.99 0.62 2.68 2.84 2.8 11.9 12.6 98 3.59 B

1.5+2.0+6.0 1.63 2.17 6.52 --- --- 3.28 10.32 10.71 0.64 2.82 3.04 2.8 12.5 13.5 98 3.66 A

1.5+2.0+7.1 1.47 1.96 6.97 --- --- 3.59 10.41 10.75 0.68 2.86 3.03 3.0 12.7 13.4 98 3.64 A

1.5+2.5+2.5 1.83 3.05 3.05 --- --- 2.43 7.93 9.21 0.55 2.05 2.58 2.4 9.1 11.4 98 3.87 A

1.5+2.5+3.5 1.79 2.98 4.17 --- --- 2.72 8.94 9.89 0.60 2.42 2.89 2.7 10.7 12.8 98 3.69 A

1.5+2.5+4.2 1.72 2.87 4.82 --- --- 2.91 9.42 9.89 0.64 2.62 2.89 2.8 11.6 12.8 98 3.60 B

1.5+2.5+5.0 1.66 2.77 5.54 --- --- 3.14 9.97 10.48 0.65 2.84 3.07 2.9 12.6 13.6 98 3.51 B

1.5+2.5+6.0 1.56 2.60 6.25 --- --- 3.42 10.41 10.71 0.66 2.87 3.04 2.9 12.7 13.5 98 3.63 A

1.5+2.5+7.1 1.41 2.34 6.66 --- --- 3.73 10.41 10.75 0.70 2.86 3.03 3.1 12.7 13.4 98 3.64 A

1.5+3.5+3.5 1.70 3.97 3.97 --- --- 3.00 9.63 9.89 0.64 2.73 2.89 2.8 12.1 12.8 98 3.53 B

1.5+3.5+4.2 1.65 3.85 4.62 --- --- 3.20 10.11 10.37 0.69 3.01 3.12 3.1 13.4 13.8 98 3.36 C

1.5+3.5+5.0 1.56 3.64 5.21 --- --- 3.42 10.41 10.49 0.70 3.07 3.07 3.1 13.6 13.6 98 3.39 C

1.5+3.5+6.0 1.42 3.31 5.68 --- --- 3.70 10.41 10.72 0.71 2.87 3.04 3.1 12.7 13.5 98 3.63 A

1.5+3.5+7.1 1.29 3.01 6.11 --- --- 4.01 10.41 10.75 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

1.5+4.2+4.2 1.58 4.42 4.42 --- --- 3.39 10.41 10.48 0.72 3.17 3.17 3.2 14.1 14.1 98 3.28 C

1.5+4.2+5.0 1.46 4.09 4.86 --- --- 3.62 10.41 10.61 0.75 3.07 3.07 3.3 13.6 13.6 98 3.39 C

1.5+4.2+6.0 1.33 3.74 5.34 --- --- 3.90 10.41 10.84 0.76 2.87 3.04 3.4 12.7 13.5 98 3.63 A

1.5+4.2+7.1 1.22 3.42 5.77 --- --- 4.21 10.41 10.87 0.81 2.86 3.02 3.6 12.7 13.4 98 3.64 A

1.5+5.0+5.0 1.36 4.53 4.53 --- --- 3.84 10.41 10.74 0.75 2.96 3.08 3.3 13.1 13.7 98 3.52 B

1.5+5.0+6.0 1.25 4.16 5.00 --- --- 4.13 10.41 10.97 0.76 2.77 2.99 3.4 12.3 13.3 98 3.76 A

1.5+5.0+7.1 1.15 3.83 5.43 --- --- 4.44 10.41 11.00 0.84 2.75 2.97 3.7 12.2 13.2 98 3.79 A

1.5+6.0+6.0 1.16 4.63 4.63 --- --- 4.41 10.41 11.20 0.77 2.62 2.90 3.4 11.6 12.9 98 3.97 A

1.5+6.0+7.1 1.07 4.28 5.06 --- --- 4.72 10.41 11.23 0.84 2.61 2.89 3.7 11.6 12.8 98 3.99 A

2.0+2.0+2.0 2.44 2.44 2.44 --- --- 2.28 7.32 8.67 0.53 1.84 2.32 2.4 8.2 10.3 98 3.98 A

2.0+2.0+2.5 2.44 2.44 3.04 --- --- 2.43 7.92 9.21 0.55 2.05 2.58 2.4 9.1 11.4 98 3.86 A

2.0+2.0+3.5 2.38 2.38 4.17 --- --- 2.72 8.93 9.89 0.60 2.42 2.89 2.7 10.7 12.8 98 3.69 A

2.0+2.0+4.2 2.30 2.30 4.81 --- --- 2.91 9.41 9.89 0.64 2.62 2.89 2.8 11.6 12.8 98 3.59 B

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

116

5MXS-E

GC_pre2_lowres.pdf 116 30/11/2011 12:31:11

Page 119: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

2.0+2.0+5.0 2.21 2.21 5.54 --- --- 3.14 9.96 10.48 0.65 2.84 3.07 2.9 12.6 13.6 98 3.51 B

2.0+2.0+6.0 2.08 2.08 6.24 --- --- 3.42 10.40 10.71 0.66 2.87 3.04 2.9 12.7 13.5 98 3.62 A

2.0+2.0+7.1 1.87 1.87 6.66 --- --- 3.73 10.40 10.75 0.70 2.86 3.03 3.1 12.7 13.4 98 3.64 A

2.0+2.5+2.5 2.43 3.05 3.05 --- --- 2.57 8.53 9.21 0.57 2.28 2.58 2.5 10.1 11.4 98 3.74 A

2.0+2.5+3.5 2.31 2.90 4.06 --- --- 2.86 9.27 9.89 0.62 2.57 2.89 2.8 11.4 12.8 98 3.61 A

2.0+2.5+4.2 2.24 2.80 4.71 --- --- 3.06 9.75 10.36 0.67 2.78 3.12 3.0 12.3 13.8 98 3.51 B

2.0+2.5+5.0 2.17 2.71 5.43 --- --- 3.28 10.31 10.48 0.67 3.02 3.07 3.0 13.4 13.6 98 3.41 B

2.0+2.5+6.0 1.98 2.48 5.94 --- --- 3.56 10.40 10.71 0.68 2.87 3.04 3.0 12.7 13.5 98 3.62 A

2.0+2.5+7.1 1.79 2.24 6.37 --- --- 3.87 10.40 10.75 0.73 2.86 3.03 3.2 12.7 13.4 98 3.64 A

2.0+3.5+3.5 2.22 3.87 3.87 --- --- 3.14 9.96 10.36 0.69 2.89 3.12 3.1 12.8 13.8 98 3.45 B

2.0+3.5+4.2 2.14 3.75 4.51 --- --- 3.34 10.40 10.55 0.72 3.18 3.23 3.2 14.1 14.3 98 3.27 C

2.0+3.5+5.0 1.98 3.47 4.95 --- --- 3.56 10.40 10.90 0.72 3.07 3.30 3.2 13.6 14.6 98 3.39 C

2.0+3.5+6.0 1.80 3.17 5.43 --- --- 3.84 10.40 10.72 0.73 2.87 3.04 3.2 12.7 13.5 98 3.62 A

2.0+3.5+7.1 1.65 2.89 5.86 --- --- 4.15 10.40 10.75 0.81 2.86 3.03 3.6 12.7 13.4 98 3.64 A

2.0+4.2+4.2 2.00 4.20 4.20 --- --- 3.53 10.40 10.56 0.74 3.12 3.23 3.3 13.8 14.3 98 3.33 C

2.0+4.2+5.0 1.86 3.90 4.64 --- --- 3.76 10.40 10.91 0.77 3.07 3.30 3.4 13.6 14.6 98 3.39 C

2.0+4.2+6.0 1.70 3.58 5.12 --- --- 4.04 10.40 10.73 0.78 2.87 3.04 3.5 12.7 13.5 98 3.62 A

2.0+4.2+7.1 1.56 3.28 5.56 --- --- 4.35 10.40 10.76 0.83 2.86 3.02 3.7 12.7 13.4 98 3.64 A

2.0+5.0+5.0 1.74 4.33 4.33 --- --- 3.99 10.40 10.63 0.80 2.96 3.08 3.5 13.1 13.7 98 3.51 B

2.0+5.0+6.0 1.60 4.00 4.80 --- --- 4.27 10.40 10.86 0.79 2.77 2.99 3.5 12.3 13.3 98 3.75 A

2.0+5.0+7.1 1.47 3.69 5.24 --- --- 4.58 10.40 10.89 0.86 2.75 2.97 3.8 12.2 13.2 98 3.78 A

2.0+6.0+6.0 1.48 4.46 4.46 --- --- 4.55 10.40 11.09 0.82 2.62 2.90 3.6 11.6 12.9 98 3.97 A

2.0+6.0+7.1 1.38 4.13 4.89 --- --- 4.86 10.40 11.12 0.87 2.61 2.89 3.9 11.6 12.8 98 3.98 A

2.5+2.5+2.5 2.98 2.98 2.98 --- --- 2.72 8.94 9.88 0.60 2.42 2.89 2.7 10.7 12.8 98 3.69 A

2.5+2.5+3.5 2.83 2.83 3.96 --- --- 3.00 9.62 9.89 0.67 2.73 2.89 3.0 12.1 12.8 98 3.52 B

2.5+2.5+4.2 2.74 2.74 4.62 --- --- 3.20 10.10 10.36 0.69 3.01 3.12 3.1 13.4 13.8 98 3.36 C

2.5+2.5+5.0 2.60 2.60 5.20 --- --- 3.42 10.40 10.89 0.70 3.07 3.30 3.1 13.6 14.6 98 3.39 C

2.5+2.5+6.0 2.36 2.36 5.68 --- --- 3.70 10.40 10.71 0.71 2.87 3.04 3.1 12.7 13.5 98 3.62 A

2.5+2.5+7.1 2.15 2.15 6.10 --- --- 4.01 10.40 10.75 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

2.5+3.5+3.5 2.71 3.80 3.80 --- --- 3.28 10.31 10.76 0.72 3.12 3.35 3.2 13.8 14.9 98 3.30 C

2.5+3.5+4.2 2.55 3.57 4.28 --- --- 3.48 10.40 10.77 0.74 3.18 3.35 3.3 14.1 14.9 98 3.27 C

2.5+3.5+5.0 2.36 3.31 4.73 --- --- 3.70 10.40 10.90 0.75 3.07 3.30 3.3 13.6 14.6 98 3.39 C

2.5+3.5+6.0 2.17 3.03 5.20 --- --- 3.99 10.40 10.72 0.76 2.87 3.04 3.4 12.7 13.5 98 3.62 A

2.5+3.5+7.1 1.98 2.78 5.64 --- --- 4.30 10.40 10.75 0.83 2.86 3.03 3.7 12.7 13.4 98 3.64 A

2.5+4.2+4.2 2.38 4.01 4.01 --- --- 3.68 10.40 10.77 0.77 3.12 3.35 3.4 13.8 14.9 98 3.33 C

2.5+4.2+5.0 2.23 3.73 4.44 --- --- 3.90 10.40 10.91 0.80 3.07 3.30 3.5 13.6 14.6 98 3.39 C

2.5+4.2+6.0 2.05 3.44 4.91 --- --- 4.18 10.40 10.73 0.81 2.87 3.04 3.6 12.7 13.5 98 3.62 A

2.5+4.2+7.1 1.88 3.17 5.35 --- --- 4.49 10.40 10.76 0.86 2.86 3.02 3.8 12.7 13.4 98 3.64 A

2.5+5.0+5.0 2.08 4.16 4.16 --- --- 4.13 10.40 10.63 0.83 2.96 3.08 3.7 13.1 13.7 98 3.51 B

2.5+5.0+6.0 1.93 3.85 4.62 --- --- 4.41 10.40 10.86 0.84 2.77 2.99 3.7 12.3 13.3 98 3.75 A

2.5+5.0+7.1 1.78 3.56 5.06 --- --- 4.72 10.40 10.89 0.89 2.75 2.97 3.9 12.2 13.2 98 3.78 A

2.5+6.0+6.0 1.80 4.30 4.30 --- --- 4.69 10.40 11.09 0.85 2.62 2.90 3.8 11.6 12.9 98 3.97 A

2.5+6.0+7.1 1.67 4.00 4.73 --- --- 5.00 10.40 11.12 0.90 2.61 2.89 4.0 11.6 12.8 98 3.98 A

3.5+3.5+3.5 3.46 3.46 3.46 --- --- 3.56 10.38 10.76 0.77 3.12 3.35 3.4 13.8 14.9 98 3.33 C

3.5+3.5+4.2 3.25 3.25 3.90 --- --- 3.76 10.40 10.77 0.80 3.12 3.35 3.5 13.8 14.9 98 3.33 C

3.5+3.5+5.0 3.03 3.03 4.34 --- --- 3.99 10.40 10.91 0.83 3.07 3.30 3.7 13.6 14.6 98 3.39 C

3.5+3.5+6.0 2.80 2.80 4.80 --- --- 4.27 10.40 10.73 0.84 2.87 3.04 3.7 12.7 13.5 98 3.62 A

3.5+3.5+7.1 2.58 2.58 5.24 --- --- 4.58 10.40 10.76 0.89 2.86 3.02 3.9 12.7 13.4 98 3.64 A

3.5+4.2+4.2 3.06 3.67 3.67 --- --- 3.96 10.40 10.78 0.85 3.11 3.34 3.8 13.8 14.8 98 3.34 C

3.5+4.2+5.0 2.87 3.44 4.09 --- --- 4.18 10.40 10.51 0.85 3.01 3.12 3.8 13.4 13.8 98 3.46 B

3.5+4.2+6.0 2.66 3.19 4.55 --- --- 4.46 10.40 10.74 0.87 2.87 3.03 3.9 12.7 13.4 98 3.62 A

3.5+4.2+7.1 2.46 2.95 4.99 --- --- 4.78 10.40 10.77 0.95 2.85 3.02 4.2 12.6 13.4 98 3.65 A

3.5+5.0+5.0 2.70 3.85 3.85 --- --- 4.41 10.40 10.64 0.89 2.96 3.07 3.9 13.1 13.6 98 3.51 B

3.5+5.0+6.0 2.51 3.59 4.30 --- --- 4.69 10.40 10.86 0.90 2.76 2.98 4.0 12.2 13.2 98 3.77 A

3.5+5.0+7.1 2.34 3.33 4.73 --- --- 5.00 10.40 10.90 0.95 2.75 2.97 4.2 12.2 13.2 98 3.78 A

3.5+6.0+6.0 2.34 4.03 4.03 --- --- 4.97 10.40 11.09 0.91 2.62 2.90 4.0 11.6 12.9 98 3.97 A

4.2+4.2+4.2 3.47 3.47 3.47 --- --- 4.15 10.40 10.79 0.88 3.11 3.34 3.9 13.8 14.8 98 3.34 C

4.2+4.2+5.0 3.26 3.26 3.88 --- --- 4.38 10.40 10.52 0.91 3.00 3.12 4.0 13.3 13.8 98 3.47 B

4.2+4.2+6.0 3.03 3.03 4.34 --- --- 4.66 10.40 10.75 0.92 2.86 3.03 4.1 12.7 13.4 98 3.64 A

4.2+4.2+7.1 2.82 2.82 4.76 --- --- 4.97 10.40 10.78 0.98 2.85 3.02 4.3 12.6 13.4 98 3.65 A

4.2+5.0+5.0 3.08 3.66 3.66 --- --- 4.61 10.40 10.64 0.91 2.96 3.07 4.0 13.1 13.6 98 3.51 B

4.2+5.0+6.0 2.87 3.42 4.11 --- --- 4.89 10.40 10.87 0.93 2.76 2.98 4.1 12.2 13.2 98 3.77 A

5.0+5.0+5.0 3.46 3.46 3.46 --- --- 4.83 10.38 10.77 0.95 2.85 3.02 4.2 12.6 13.4 98 3.64 A

1.5+1.5+1.5+1.5 1.83 1.83 1.83 1.83 --- 2.28 7.32 8.82 0.46 1.72 2.24 2.0 7.6 9.9 98 4.26 A

1.5+1.5+1.5+2.0 1.83 1.83 1.83 2.44 --- 2.43 7.93 9.42 0.48 1.93 2.44 2.1 8.6 10.8 98 4.11 A

1.5+1.5+1.5+2.5 1.83 1.83 1.83 3.05 --- 2.58 8.54 9.42 0.50 2.10 2.44 2.2 9.3 10.8 98 4.07 A

1.5+1.5+1.5+3.5 1.74 1.74 1.74 4.06 --- 2.86 9.28 10.19 0.54 2.39 2.75 2.4 10.6 12.2 98 3.88 A

1.5+1.5+1.5+4.2 1.68 1.68 1.68 4.71 --- 3.06 9.76 10.74 0.59 2.59 3.03 2.6 11.5 13.4 98 3.77 A

1.5+1.5+1.5+5.0 1.63 1.63 1.63 5.43 --- 3.28 10.32 10.86 0.59 2.76 2.98 2.6 12.2 13.2 98 3.74 A

1.5+1.5+1.5+6.0 1.49 1.49 1.49 5.95 --- 3.56 10.41 11.09 0.60 2.62 2.90 2.7 11.6 12.9 98 3.97 A

1.5+1.5+1.5+7.1 1.35 1.35 1.35 6.37 --- 3.87 10.41 11.12 0.66 2.61 2.88 2.9 11.6 12.8 98 3.99 A

1.5+1.5+2.0+2.0 1.83 1.83 2.44 2.44 --- 2.58 8.54 9.42 0.50 2.10 2.44 2.2 9.3 10.8 98 4.07 A

1.5+1.5+2.0+2.5 1.79 1.79 2.38 2.98 --- 2.72 8.94 10.18 0.52 2.24 2.76 2.3 9.9 12.2 98 3.99 A

1.5+1.5+2.0+3.5 1.70 1.70 2.27 3.97 --- 3.00 9.63 10.19 0.59 2.49 2.75 2.6 11.0 12.2 98 3.87 A

1.5+1.5+2.0+4.2 1.65 1.65 2.20 4.62 --- 3.20 10.11 10.74 0.61 2.75 3.03 2.7 12.2 13.4 98 3.68 A

1.5+1.5+2.0+5.0 1.56 1.56 2.08 5.21 --- 3.42 10.41 10.86 0.64 2.76 2.98 2.8 12.2 13.2 98 3.77 A

1.5+1.5+2.0+6.0 1.42 1.42 1.89 5.68 --- 3.70 10.41 11.09 0.62 2.62 2.90 2.8 11.6 12.9 98 3.97 A

1.5+1.5+2.0+7.1 1.29 1.29 1.72 6.11 --- 4.01 10.41 11.12 0.69 2.61 2.88 3.1 11.6 12.8 98 3.99 A

1.5+1.5+2.5+2.5 1.74 1.74 2.90 2.90 --- 2.86 9.28 10.18 0.57 2.39 2.76 2.5 10.6 12.2 98 3.88 A

1.5+1.5+2.5+3.5 1.66 1.66 2.77 3.88 --- 3.14 9.97 10.73 0.61 2.65 3.04 2.7 11.8 13.5 98 3.76 A

1.5+1.5+2.5+4.2 1.61 1.61 2.68 4.51 --- 3.34 10.41 10.74 0.63 2.87 3.03 2.8 12.7 13.4 98 3.63 A

1.5+1.5+2.5+5.0 1.49 1.49 2.48 4.96 --- 3.56 10.41 10.86 0.66 2.76 2.98 2.9 12.2 13.2 98 3.77 A

1.5+1.5+2.5+6.0 1.36 1.36 2.26 5.43 --- 3.84 10.41 11.09 0.67 2.62 2.90 3.0 11.6 12.9 98 3.97 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

117

5MXS-E

GC_pre2_lowres.pdf 117 30/11/2011 12:31:12

Page 120: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+1.5+2.5+7.1 1.24 1.24 2.07 5.87 --- 4.15 10.41 11.12 0.71 2.61 2.88 3.1 11.6 12.8 98 3.99 A

1.5+1.5+3.5+3.5 1.56 1.56 3.64 3.64 --- 3.42 10.41 10.74 0.66 2.87 3.03 2.9 12.7 13.4 98 3.63 A

1.5+1.5+3.5+4.2 1.46 1.46 3.41 4.09 --- 3.62 10.41 10.74 0.68 2.86 3.03 3.0 12.7 13.4 98 3.64 A

1.5+1.5+3.5+5.0 1.36 1.36 3.17 4.53 --- 3.84 10.41 10.87 0.71 2.76 2.98 3.1 12.2 13.2 98 3.77 A

1.5+1.5+3.5+6.0 1.25 1.25 2.91 5.00 --- 4.13 10.41 11.10 0.72 2.61 2.89 3.2 11.6 12.8 98 3.99 A

1.5+1.5+3.5+7.1 1.15 1.15 2.68 5.43 --- 4.44 10.41 11.13 0.79 2.60 2.88 3.5 11.5 12.8 98 4.00 A

1.5+1.5+4.2+4.2 1.37 1.37 3.84 3.84 --- 3.82 10.41 10.75 0.73 2.86 3.03 3.2 12.7 13.4 98 3.64 A

1.5+1.5+4.2+5.0 1.28 1.28 3.58 4.27 --- 4.04 10.41 10.88 0.76 2.76 2.98 3.4 12.2 13.2 98 3.77 A

1.5+1.5+4.2+6.0 1.18 1.18 3.31 4.73 --- 4.32 10.41 11.11 0.77 2.61 2.89 3.4 11.6 12.8 98 3.99 A

1.5+1.5+4.2+7.1 1.09 1.09 3.06 5.17 --- 4.63 10.41 11.14 0.81 2.60 2.88 3.6 11.5 12.8 98 4.00 A

1.5+1.5+5.0+5.0 1.20 1.20 4.00 4.00 --- 4.27 10.41 11.01 0.76 2.71 2.93 3.4 12.0 13.0 98 3.84 A

1.5+1.5+5.0+6.0 1.12 1.12 3.72 4.46 --- 4.55 10.41 11.23 0.77 2.56 2.90 3.4 11.4 12.9 98 4.07 A

1.5+1.5+5.0+7.1 1.03 1.03 3.45 4.89 --- 4.86 10.41 11.27 0.84 2.50 2.88 3.7 11.1 12.8 98 4.16 A

1.5+1.5+6.0+6.0 1.04 1.04 4.16 4.16 --- 4.83 10.41 11.46 0.80 2.43 2.81 3.5 10.8 12.5 98 4.28 A

1.5+2.0+2.0+2.0 1.79 2.38 2.38 2.38 --- 2.72 8.94 10.18 0.52 2.24 2.76 2.3 9.9 12.2 98 3.99 A

1.5+2.0+2.0+2.5 1.74 2.32 2.32 2.90 --- 2.86 9.28 10.18 0.57 2.39 2.76 2.5 10.6 12.2 98 3.88 A

1.5+2.0+2.0+3.5 1.66 2.22 2.22 3.88 --- 3.14 9.97 10.73 0.61 2.65 3.04 2.7 11.8 13.5 98 3.76 A

1.5+2.0+2.0+4.2 1.61 2.15 2.15 4.51 --- 3.34 10.41 10.74 0.63 2.87 3.03 2.8 12.7 13.4 98 3.63 A

1.5+2.0+2.0+5.0 1.49 1.98 1.98 4.96 --- 3.56 10.41 10.86 0.66 2.76 2.98 2.9 12.2 13.2 98 3.77 A

1.5+2.0+2.0+6.0 1.36 1.81 1.81 5.43 --- 3.84 10.41 11.09 0.67 2.62 2.90 3.0 11.6 12.9 98 3.97 A

1.5+2.0+2.0+7.1 1.24 1.65 1.65 5.87 --- 4.15 10.41 11.12 0.71 2.61 2.88 3.1 11.6 12.8 98 3.99 A

1.5+2.0+2.5+2.5 1.70 2.27 2.83 2.83 --- 3.00 9.63 10.18 0.59 2.54 2.76 2.6 11.3 12.2 98 3.79 A

1.5+2.0+2.5+3.5 1.63 2.17 2.72 3.80 --- 3.28 10.32 10.73 0.63 2.81 3.04 2.8 12.5 13.5 98 3.67 A

1.5+2.0+2.5+4.2 1.53 2.04 2.55 4.29 --- 3.48 10.41 10.74 0.66 2.87 3.03 2.9 12.7 13.4 98 3.63 A

1.5+2.0+2.5+5.0 1.42 1.89 2.37 4.73 --- 3.70 10.41 10.86 0.68 2.76 2.98 3.0 12.2 13.2 98 3.77 A

1.5+2.0+2.5+6.0 1.30 1.74 2.17 5.21 --- 3.99 10.41 11.09 0.69 2.62 2.90 3.1 11.6 12.9 98 3.97 A

1.5+2.0+2.5+7.1 1.19 1.59 1.99 5.64 --- 4.30 10.41 11.12 0.74 2.61 2.88 3.3 11.6 12.8 98 3.99 A

1.5+2.0+3.5+3.5 1.49 1.98 3.47 3.47 --- 3.56 10.41 10.74 0.68 2.87 3.03 3.0 12.7 13.4 98 3.63 A

1.5+2.0+3.5+4.2 1.39 1.86 3.25 3.90 --- 3.76 10.41 10.74 0.73 2.86 3.03 3.2 12.7 13.4 98 3.64 A

1.5+2.0+3.5+5.0 1.30 1.74 3.04 4.34 --- 3.99 10.41 10.87 0.73 2.76 2.98 3.2 12.2 13.2 98 3.77 A

1.5+2.0+3.5+6.0 1.20 1.60 2.80 4.80 --- 4.27 10.41 11.10 0.74 2.61 2.89 3.3 11.6 12.8 98 3.99 A

1.5+2.0+3.5+7.1 1.11 1.48 2.58 5.24 --- 4.58 10.41 11.13 0.81 2.60 2.88 3.6 11.5 12.8 98 4.00 A

1.5+2.0+4.2+4.2 1.31 1.75 3.67 3.67 --- 3.96 10.41 10.75 0.75 2.86 3.03 3.3 12.7 13.4 98 3.64 A

1.5+2.0+4.2+5.0 1.23 1.64 3.44 4.10 --- 4.18 10.41 10.88 0.78 2.76 2.98 3.5 12.2 13.2 98 3.77 A

1.5+2.0+4.2+6.0 1.14 1.52 3.19 4.56 --- 4.46 10.41 11.11 0.79 2.61 2.89 3.5 11.6 12.8 98 3.99 A

1.5+2.0+4.2+7.1 1.06 1.41 2.95 4.99 --- 4.78 10.41 11.14 0.84 2.60 2.88 3.7 11.5 12.8 98 4.00 A

1.5+2.0+5.0+5.0 1.16 1.54 3.86 3.86 --- 4.41 10.41 11.01 0.79 2.71 2.93 3.5 12.0 13.0 98 3.84 A

1.5+2.0+5.0+6.0 1.08 1.44 3.59 4.31 --- 4.69 10.41 11.23 0.82 2.56 2.90 3.6 11.4 12.9 98 4.07 A

1.5+2.0+5.0+7.1 1.00 1.33 3.34 4.74 --- 5.00 10.41 11.27 0.87 2.50 2.88 3.9 11.1 12.8 98 4.16 A

1.5+2.0+6.0+6.0 1.01 1.34 4.03 4.03 --- 4.97 10.41 11.46 0.83 2.43 2.81 3.7 10.8 12.5 98 4.28 A

1.5+2.5+2.5+2.5 1.66 2.77 2.77 2.77 --- 3.14 9.97 10.72 0.61 2.65 3.04 2.7 11.8 13.5 98 3.76 A

1.5+2.5+2.5+3.5 1.56 2.60 2.60 3.64 --- 3.42 10.41 10.73 0.66 2.87 3.04 2.9 12.7 13.5 98 3.63 A

1.5+2.5+2.5+4.2 1.46 2.43 2.43 4.09 --- 3.62 10.41 10.74 0.68 2.87 3.03 3.0 12.7 13.4 98 3.63 A

1.5+2.5+2.5+5.0 1.36 2.26 2.26 4.53 --- 3.84 10.41 10.86 0.71 2.76 2.98 3.1 12.2 13.2 98 3.77 A

1.5+2.5+2.5+6.0 1.25 2.08 2.08 5.00 --- 4.13 10.41 11.09 0.72 2.62 2.90 3.2 11.6 12.9 98 3.97 A

1.5+2.5+2.5+7.1 1.15 1.91 1.91 5.43 --- 4.44 10.41 11.12 0.79 2.61 2.88 3.5 11.6 12.8 98 3.99 A

1.5+2.5+3.5+3.5 1.42 2.37 3.31 3.31 --- 3.70 10.41 10.74 0.71 2.87 3.03 3.1 12.7 13.4 98 3.63 A

1.5+2.5+3.5+4.2 1.33 2.22 3.11 3.74 --- 3.90 10.41 10.74 0.76 2.86 3.03 3.4 12.7 13.4 98 3.64 A

1.5+2.5+3.5+5.0 1.25 2.08 2.91 4.16 --- 4.13 10.41 10.87 0.76 2.76 2.98 3.4 12.2 13.2 98 3.77 A

1.5+2.5+3.5+6.0 1.16 1.93 2.70 4.63 --- 4.41 10.41 11.10 0.77 2.61 2.89 3.4 11.6 12.8 98 3.99 A

1.5+2.5+3.5+7.1 1.07 1.78 2.50 5.06 --- 4.72 10.41 11.13 0.84 2.60 2.88 3.7 11.5 12.8 98 4.00 A

1.5+2.5+4.2+4.2 1.26 2.10 3.53 3.53 --- 4.10 10.41 10.75 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

1.5+2.5+4.2+5.0 1.18 1.97 3.31 3.94 --- 4.32 10.41 10.88 0.81 2.76 2.98 3.6 12.2 13.2 98 3.77 A

1.5+2.5+4.2+6.0 1.10 1.83 3.08 4.40 --- 4.61 10.41 11.11 0.82 2.61 2.89 3.6 11.6 12.8 98 3.99 A

1.5+2.5+4.2+7.1 1.02 1.70 2.86 4.83 --- 4.92 10.41 11.14 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

1.5+2.5+5.0+5.0 1.12 1.86 3.72 3.72 --- 4.10 10.41 10.75 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

1.5+2.5+5.0+6.0 1.04 1.74 3.47 4.16 --- 4.32 10.41 10.88 0.81 2.76 2.98 3.6 12.2 13.2 98 3.77 A

1.5+3.5+3.5+3.5 1.30 3.04 3.04 3.04 --- 3.99 10.41 10.74 0.76 2.86 3.03 3.4 12.7 13.4 98 3.64 A

1.5+3.5+3.5+4.2 1.23 2.87 2.87 3.44 --- 4.18 10.41 10.75 0.81 2.86 3.03 3.6 12.7 13.4 98 3.64 A

1.5+3.5+3.5+5.0 1.16 2.70 2.70 3.86 --- 4.41 10.41 10.88 0.84 2.76 2.98 3.7 12.2 13.2 98 3.77 A

1.5+3.5+3.5+6.0 1.08 2.51 2.51 4.31 --- 4.69 10.41 11.11 0.85 2.61 2.89 3.8 11.6 12.8 98 3.99 A

1.5+3.5+3.5+7.1 1.00 2.34 2.34 4.74 --- 5.00 10.41 11.14 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

1.5+3.5+4.2+4.2 1.17 2.72 3.26 3.26 --- 4.38 10.41 10.76 0.83 2.86 3.02 3.7 12.7 13.4 98 3.64 A

1.5+3.5+4.2+5.0 1.10 2.57 3.08 3.67 --- 4.61 10.41 10.89 0.86 2.75 2.98 3.8 12.2 13.2 98 3.79 A

1.5+3.5+4.2+6.0 1.03 2.40 2.88 4.11 --- 4.89 10.41 11.12 0.87 2.61 2.89 3.9 11.6 12.8 98 3.99 A

1.5+3.5+5.0+5.0 1.04 2.43 3.47 3.47 --- 4.83 10.41 11.01 0.90 2.71 2.93 4.0 12.0 13.0 98 3.84 A

1.5+4.2+4.2+4.2 1.11 3.10 3.10 3.10 --- 4.58 10.41 10.77 0.89 2.85 3.02 3.9 12.6 13.4 98 3.65 A

1.5+4.2+4.2+5.0 1.05 2.93 2.93 3.49 --- 4.80 10.41 10.90 0.92 2.75 2.97 4.1 12.2 13.2 98 3.79 A

2.0+2.0+2.0+2.0 2.32 2.32 2.32 2.32 --- 2.86 9.28 10.18 0.57 2.39 2.76 2.5 10.6 12.2 98 3.88 A

2.0+2.0+2.0+2.5 2.26 2.26 2.26 2.84 --- 3.00 9.62 10.18 0.59 2.49 2.76 2.6 11.0 12.2 98 3.86 A

2.0+2.0+2.0+3.5 2.17 2.17 2.17 3.80 --- 3.28 10.31 10.73 0.63 2.81 3.04 2.8 12.5 13.5 98 3.67 A

2.0+2.0+2.0+4.2 2.04 2.04 2.04 4.28 --- 3.48 10.40 10.74 0.66 2.87 3.03 2.9 12.7 13.4 98 3.62 A

2.0+2.0+2.0+5.0 1.89 1.89 1.89 4.73 --- 3.70 10.40 10.86 0.68 2.76 2.99 3.0 12.2 13.3 98 3.77 A

2.0+2.0+2.0+6.0 1.73 1.73 1.73 5.21 --- 3.99 10.40 11.09 0.69 2.62 2.90 3.1 11.6 12.9 98 3.97 A

2.0+2.0+2.0+7.1 1.59 1.59 1.59 5.63 --- 4.30 10.40 11.12 0.74 2.61 2.88 3.3 11.6 12.8 98 3.98 A

2.0+2.0+2.5+2.5 2.21 2.21 2.77 2.77 --- 3.14 9.96 10.72 0.61 2.65 3.04 2.7 11.8 13.5 98 3.76 A

2.0+2.0+2.5+3.5 2.08 2.08 2.60 3.64 --- 3.42 10.40 10.73 0.66 2.87 3.04 2.9 12.7 13.5 98 3.62 A

2.0+2.0+2.5+4.2 1.94 1.94 2.44 4.08 --- 3.62 10.40 10.74 0.68 2.87 3.03 3.0 12.7 13.4 98 3.62 A

2.0+2.0+2.5+5.0 1.81 1.81 2.26 4.52 --- 3.84 10.40 10.86 0.71 2.76 2.99 3.1 12.2 13.3 98 3.77 A

2.0+2.0+2.5+6.0 1.66 1.66 2.08 5.00 --- 4.13 10.40 11.09 0.72 2.62 2.90 3.2 11.6 12.9 98 3.97 A

2.0+2.0+2.5+7.1 1.53 1.53 1.91 5.43 --- 4.44 10.40 11.12 0.79 2.61 2.88 3.5 11.6 12.8 98 3.98 A

2.0+2.0+3.5+3.5 1.89 1.89 3.31 3.31 --- 3.70 10.40 10.74 0.71 2.87 3.03 3.1 12.7 13.4 98 3.62 A

2.0+2.0+3.5+4.2 1.78 1.78 3.11 3.73 --- 3.90 10.40 10.74 0.76 2.86 3.03 3.4 12.7 13.4 98 3.64 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

118

5MXS-E

GC_pre2_lowres.pdf 118 30/11/2011 12:31:12

Page 121: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

2.0+2.0+3.5+5.0 1.66 1.66 2.91 4.17 --- 4.13 10.40 10.87 0.76 2.76 2.98 3.4 12.2 13.2 98 3.77 A

2.0+2.0+3.5+6.0 1.54 1.54 2.70 4.62 --- 4.41 10.40 11.10 0.77 2.61 2.89 3.4 11.6 12.8 98 3.98 A

2.0+2.0+3.5+7.1 1.42 1.42 2.49 5.07 --- 4.72 10.40 11.13 0.84 2.60 2.88 3.7 11.5 12.8 98 4.00 A

2.0+2.0+4.2+4.2 1.68 1.68 3.52 3.52 --- 4.10 10.40 10.75 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

2.0+2.0+4.2+5.0 1.58 1.58 3.31 3.93 --- 4.32 10.40 10.88 0.81 2.76 2.98 3.6 12.2 13.2 98 3.77 A

2.0+2.0+4.2+6.0 1.46 1.46 3.09 4.39 --- 4.61 10.40 11.11 0.82 2.61 2.89 3.6 11.6 12.8 98 3.98 A

2.0+2.0+4.2+7.1 1.36 1.36 2.85 4.83 --- 4.92 10.40 11.14 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

2.0+2.0+5.0+5.0 1.49 1.49 3.71 3.71 --- 4.55 10.40 11.01 0.84 2.71 2.93 3.7 12.0 13.0 98 3.84 A

2.0+2.0+5.0+6.0 1.39 1.39 3.47 4.15 --- 4.83 10.40 11.23 0.85 2.51 2.90 3.8 11.1 12.9 98 4.14 A

2.0+2.5+2.5+2.5 2.18 2.71 2.71 2.71 --- 3.28 10.31 10.72 0.64 2.82 3.04 2.8 12.5 13.5 98 3.66 A

2.0+2.5+2.5+3.5 1.97 2.48 2.48 3.47 --- 3.56 10.40 10.73 0.68 2.87 3.04 3.0 12.7 13.5 98 3.62 A

2.0+2.5+2.5+4.2 1.86 2.32 2.32 3.90 --- 3.76 10.40 10.74 0.73 2.87 3.03 3.2 12.7 13.4 98 3.62 A

2.0+2.5+2.5+5.0 1.73 2.17 2.17 4.33 --- 3.99 10.40 10.86 0.73 2.76 2.99 3.2 12.2 13.3 98 3.77 A

2.0+2.5+2.5+6.0 1.60 2.00 2.00 4.80 --- 4.27 10.40 11.09 0.74 2.62 2.90 3.3 11.6 12.9 98 3.97 A

2.0+2.5+2.5+7.1 1.48 1.84 1.84 5.24 --- 4.58 10.40 11.12 0.82 2.61 2.88 3.6 11.6 12.8 98 3.98 A

2.0+2.5+3.5+3.5 1.80 2.26 3.17 3.17 --- 3.84 10.40 10.74 0.73 2.87 3.03 3.2 12.7 13.4 98 3.62 A

2.0+2.5+3.5+4.2 1.71 2.13 2.98 3.58 --- 4.04 10.40 10.74 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

2.0+2.5+3.5+5.0 1.60 2.00 2.80 4.00 --- 4.27 10.40 10.87 0.78 2.76 2.98 3.5 12.2 13.2 98 3.77 A

2.0+2.5+3.5+6.0 1.48 1.86 2.60 4.46 --- 4.55 10.40 11.10 0.82 2.61 2.89 3.6 11.6 12.8 98 3.98 A

2.0+2.5+3.5+7.1 1.38 1.72 2.41 4.89 --- 4.86 10.40 11.13 0.87 2.60 2.88 3.9 11.5 12.8 98 4.00 A

2.0+2.5+4.2+4.2 1.61 2.01 3.39 3.39 --- 4.24 10.40 10.75 0.81 2.86 3.03 3.6 12.7 13.4 98 3.64 A

2.0+2.5+4.2+5.0 1.52 1.90 3.19 3.79 --- 4.46 10.40 10.88 0.84 2.76 2.98 3.7 12.2 13.2 98 3.77 A

2.0+2.5+4.2+6.0 1.42 1.77 2.97 4.24 --- 4.75 10.40 11.11 0.85 2.61 2.89 3.8 11.6 12.8 98 3.98 A

2.0+2.5+5.0+5.0 1.43 1.79 3.59 3.59 --- 4.69 10.40 11.01 0.87 2.71 2.93 3.9 12.0 13.0 98 3.84 A

2.0+2.5+5.0+6.0 1.34 1.68 3.35 4.03 --- 4.97 10.40 11.23 0.88 2.51 2.90 3.9 11.1 12.9 98 4.14 A

2.0+3.5+3.5+3.5 1.67 2.91 2.91 2.91 --- 4.13 10.40 10.74 0.78 2.86 3.03 3.5 12.7 13.4 98 3.64 A

2.0+3.5+3.5+4.2 1.58 2.76 2.76 3.30 --- 4.32 10.40 10.75 0.84 2.86 3.03 3.7 12.7 13.4 98 3.64 A

2.0+3.5+3.5+5.0 1.49 2.60 2.60 3.71 --- 4.55 10.40 10.88 0.87 2.76 2.98 3.9 12.2 13.2 98 3.77 A

2.0+3.5+3.5+6.0 1.38 2.43 2.43 4.16 --- 4.83 10.40 11.11 0.87 2.61 2.89 3.9 11.6 12.8 98 3.98 A

2.0+3.5+4.2+4.2 1.50 2.62 3.14 3.14 --- 4.52 10.40 10.76 0.89 2.86 3.02 3.9 12.7 13.4 98 3.64 A

2.0+3.5+4.2+5.0 1.41 2.48 2.97 3.54 --- 4.75 10.40 10.89 0.89 2.75 2.98 3.9 12.2 13.2 98 3.78 A

2.0+3.5+5.0+5.0 1.35 2.35 3.35 3.35 --- 4.97 10.40 11.01 0.92 2.65 2.93 4.1 11.8 13.0 98 3.92 A

2.0+4.2+4.2+4.2 1.43 2.99 2.99 2.99 --- 4.72 10.40 10.77 0.92 2.85 3.02 4.1 12.6 13.4 98 3.65 A

2.0+4.2+4.2+5.0 1.35 2.84 2.84 3.37 --- 4.94 10.40 10.90 0.95 2.75 2.97 4.2 12.2 13.2 98 3.78 A

2.5+2.5+2.5+2.5 2.60 2.60 2.60 2.60 --- 3.42 10.40 10.72 0.66 2.87 3.04 2.9 12.7 13.5 98 3.62 A

2.5+2.5+2.5+3.5 2.36 2.36 2.36 3.32 --- 3.70 10.40 10.73 0.71 2.87 3.04 3.1 12.7 13.5 98 3.62 A

2.5+2.5+2.5+4.2 2.22 2.22 2.22 3.74 --- 3.90 10.40 10.74 0.76 2.87 3.03 3.4 12.7 13.4 98 3.62 A

2.5+2.5+2.5+5.0 2.08 2.08 2.08 4.16 --- 4.13 10.40 10.86 0.76 2.76 2.99 3.4 12.2 13.3 98 3.77 A

2.5+2.5+2.5+6.0 1.93 1.93 1.93 4.61 --- 4.41 10.40 11.09 0.77 2.62 2.90 3.4 11.6 12.9 98 3.97 A

2.5+2.5+2.5+7.1 1.78 1.78 1.78 5.06 --- 4.72 10.40 11.12 0.84 2.61 2.88 3.7 11.6 12.8 98 3.98 A

2.5+2.5+3.5+3.5 2.17 2.17 3.03 3.03 --- 3.99 10.40 10.74 0.76 2.87 3.03 3.4 12.7 13.4 98 3.62 A

2.5+2.5+3.5+4.2 2.05 2.05 2.87 3.43 --- 4.18 10.40 10.74 0.81 2.86 3.03 3.6 12.7 13.4 98 3.64 A

2.5+2.5+3.5+5.0 1.93 1.93 2.70 3.84 --- 4.41 10.40 10.87 0.84 2.76 2.98 3.7 12.2 13.2 98 3.77 A

2.5+2.5+3.5+6.0 1.79 1.79 2.51 4.31 --- 4.69 10.40 11.10 0.85 2.61 2.89 3.8 11.6 12.8 98 3.98 A

2.5+2.5+3.5+7.1 1.67 1.67 2.33 4.73 --- 5.00 10.40 11.13 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

2.5+2.5+4.2+4.2 1.94 1.94 3.26 3.26 --- 4.38 10.40 10.75 0.84 2.86 3.03 3.7 12.7 13.4 98 3.64 A

2.5+2.5+4.2+5.0 1.83 1.83 3.08 3.66 --- 4.61 10.40 10.88 0.87 2.76 2.98 3.9 12.2 13.2 98 3.77 A

2.5+2.5+4.2+6.0 1.71 1.71 2.87 4.11 --- 4.89 10.40 11.11 0.87 2.61 2.89 3.9 11.6 12.8 98 3.98 A

2.5+2.5+5.0+5.0 1.73 1.73 3.47 3.47 --- 4.83 10.40 11.01 0.90 2.71 2.93 4.0 12.0 13.0 98 3.84 A

2.5+3.5+3.5+3.5 2.00 2.80 2.80 2.80 --- 4.27 10.40 10.74 0.84 2.86 3.03 3.7 12.7 13.4 98 3.64 A

2.5+3.5+3.5+4.2 1.90 2.66 2.66 3.18 --- 4.46 10.40 10.75 0.86 2.86 3.03 3.8 12.7 13.4 98 3.64 A

2.5+3.5+3.5+5.0 1.79 2.51 2.51 3.59 --- 4.69 10.40 10.88 0.89 2.76 2.98 3.9 12.2 13.2 98 3.77 A

2.5+3.5+3.5+6.0 1.67 2.35 2.35 4.03 --- 4.97 10.40 11.11 0.90 2.61 2.89 4.0 11.6 12.8 98 3.98 A

2.5+3.5+4.2+4.2 1.81 2.53 3.03 3.03 --- 4.66 10.40 10.76 0.92 2.86 3.02 4.1 12.7 13.4 98 3.64 A

2.5+3.5+4.2+5.0 1.72 2.39 2.87 3.42 --- 4.89 10.40 10.89 0.92 2.75 2.98 4.1 12.2 13.2 98 3.78 A

2.5+4.2+4.2+4.2 1.73 2.89 2.89 2.89 --- 4.86 10.40 10.77 0.95 2.85 3.02 4.2 12.6 13.4 98 3.65 A

3.5+3.5+3.5+3.5 2.60 2.60 2.60 2.60 --- 4.55 10.40 10.75 0.89 2.86 3.03 3.9 12.7 13.4 98 3.64 A

3.5+3.5+3.5+4.2 2.48 2.48 2.48 2.96 --- 4.75 10.40 10.76 0.92 2.86 3.02 4.1 12.7 13.4 98 3.64 A

3.5+3.5+3.5+5.0 2.35 2.35 2.35 3.35 --- 4.97 10.40 10.89 0.95 2.76 2.98 4.2 12.2 13.2 98 3.77 A

3.5+3.5+4.2+4.2 2.36 2.36 2.84 2.84 --- 4.94 10.40 10.77 0.98 2.85 3.02 4.3 12.6 13.4 98 3.65 A

1.5+1.5+1.5+1.5+1.5 1.79 1.79 1.79 1.79 1.79 2.72 8.93 10.48 0.45 2.12 2.68 2.0 9.4 11.9 98 4.21 A

1.5+1.5+1.5+1.5+2.0 1.74 1.74 1.74 1.74 2.32 2.86 9.27 10.48 0.47 2.21 2.68 2.1 9.8 11.9 98 4.19 A

1.5+1.5+1.5+1.5+2.5 1.70 1.70 1.70 1.70 2.83 3.00 9.62 10.48 0.51 2.31 2.68 2.3 10.2 11.9 98 4.16 A

1.5+1.5+1.5+1.5+3.5 1.63 1.63 1.63 1.63 3.80 3.28 10.31 11.11 0.55 2.56 2.89 2.4 11.4 12.8 98 4.03 A

1.5+1.5+1.5+1.5+4.2 1.53 1.53 1.53 1.53 4.28 3.48 10.40 11.11 0.59 2.61 2.89 2.6 11.6 12.8 98 3.98 A

1.5+1.5+1.5+1.5+5.0 1.42 1.42 1.42 1.42 4.73 3.70 10.40 11.24 0.60 2.51 2.90 2.7 11.1 12.9 98 4.14 A

1.5+1.5+1.5+1.5+6.0 1.30 1.30 1.30 1.30 5.20 3.99 10.40 11.47 0.60 2.38 2.81 2.7 10.6 12.5 98 4.37 A

1.5+1.5+1.5+1.5+7.1 1.19 1.19 1.19 1.19 5.64 4.30 10.40 11.50 0.66 2.36 2.79 2.9 10.5 12.4 98 4.41 A

1.5+1.5+1.5+2.0+2.0 1.70 1.70 1.70 2.26 2.26 3.00 9.62 10.48 0.51 2.31 2.68 2.3 10.2 11.9 98 4.16 A

1.5+1.5+1.5+2.0+2.5 1.66 1.66 1.66 2.21 2.77 3.14 9.96 11.10 0.53 2.46 2.89 2.4 10.9 12.8 98 4.05 A

1.5+1.5+1.5+2.0+3.5 1.56 1.56 1.56 2.08 3.64 3.42 10.40 11.11 0.57 2.61 2.89 2.5 11.6 12.8 98 3.98 A

1.5+1.5+1.5+2.0+4.2 1.46 1.46 1.46 1.94 4.08 3.62 10.40 11.11 0.62 2.61 2.89 2.8 11.6 12.8 98 3.98 A

1.5+1.5+1.5+2.0+5.0 1.36 1.36 1.36 1.81 4.52 3.84 10.40 11.24 0.62 2.51 2.90 2.8 11.1 12.9 98 4.14 A

1.5+1.5+1.5+2.0+6.0 1.25 1.25 1.25 1.66 4.99 4.13 10.40 11.47 0.65 2.38 2.81 2.9 10.6 12.5 98 4.37 A

1.5+1.5+1.5+2.0+7.1 1.15 1.15 1.15 1.53 5.43 4.44 10.40 11.50 0.69 2.36 2.79 3.1 10.5 12.4 98 4.41 A

1.5+1.5+1.5+2.5+2.5 1.63 1.63 1.63 2.71 2.71 3.28 10.31 11.10 0.55 2.56 2.89 2.4 11.4 12.8 98 4.03 A

1.5+1.5+1.5+2.5+3.5 1.49 1.49 1.49 2.48 3.47 3.56 10.40 11.11 0.60 2.61 2.89 2.7 11.6 12.8 98 3.98 A

1.5+1.5+1.5+2.5+4.2 1.39 1.39 1.39 2.32 3.90 3.76 10.40 11.11 0.64 2.61 2.89 2.8 11.6 12.8 98 3.98 A

1.5+1.5+1.5+2.5+5.0 1.30 1.30 1.30 2.17 4.33 3.99 10.40 11.24 0.66 2.51 2.90 2.9 11.1 12.9 98 4.14 A

1.5+1.5+1.5+2.5+6.0 1.20 1.20 1.20 2.00 4.80 4.27 10.40 11.47 0.67 2.38 2.81 3.0 10.6 12.5 98 4.37 A

1.5+1.5+1.5+2.5+7.1 1.11 1.11 1.11 1.84 5.24 4.58 10.40 11.50 0.71 2.36 2.79 3.1 10.5 12.4 98 4.41 A

1.5+1.5+1.5+3.5+3.5 1.36 1.36 1.36 3.17 3.17 3.84 10.40 11.11 0.66 2.61 2.89 2.9 11.6 12.8 98 3.98 A

1.5+1.5+1.5+3.5+4.2 1.28 1.28 1.28 2.98 3.58 4.04 10.40 11.12 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

119

5MXS-E

GC_pre2_lowres.pdf 119 30/11/2011 12:31:12

Page 122: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+1.5+1.5+3.5+5.0 1.20 1.20 1.20 2.80 4.00 4.27 10.40 11.25 0.71 2.51 2.89 3.1 11.1 12.8 98 4.14 A

1.5+1.5+1.5+3.5+6.0 1.11 1.11 1.11 2.60 4.46 4.55 10.40 11.48 0.72 2.37 2.80 3.2 10.5 12.4 98 4.39 A

1.5+1.5+1.5+3.5+7.1 1.03 1.03 1.03 2.41 4.89 4.86 10.40 11.51 0.79 2.36 2.79 3.5 10.5 12.4 98 4.41 A

1.5+1.5+1.5+4.2+4.2 1.21 1.21 1.21 3.39 3.39 4.24 10.40 11.13 0.73 2.60 2.88 3.2 11.5 12.8 98 4.00 A

1.5+1.5+1.5+4.2+5.0 1.14 1.14 1.14 3.19 3.80 4.46 10.40 11.26 0.76 2.50 2.89 3.4 11.1 12.8 98 4.16 A

1.5+1.5+1.5+4.2+6.0 1.06 1.06 1.06 2.97 4.24 4.75 10.40 11.49 0.77 2.37 2.80 3.4 10.5 12.4 98 4.39 A

1.5+1.5+1.5+5.0+5.0 1.08 1.08 1.08 3.59 3.59 4.69 10.40 11.38 0.76 2.46 2.84 3.4 10.9 12.6 98 4.23 A

1.5+1.5+1.5+5.0+6.0 1.01 1.01 1.01 3.35 4.03 4.97 10.40 11.61 0.79 2.32 2.75 3.5 10.3 12.2 98 4.48 A

1.5+1.5+2.0+2.0+2.0 1.66 1.66 2.21 2.21 2.21 3.14 9.96 11.10 0.53 2.46 2.89 2.4 10.9 12.8 98 4.05 A

1.5+1.5+2.0+2.0+2.5 1.63 1.63 2.17 2.17 2.71 3.28 10.31 11.10 0.55 2.56 2.89 2.4 11.4 12.8 98 4.03 A

1.5+1.5+2.0+2.0+3.5 1.49 1.49 1.98 1.98 3.47 3.56 10.40 11.11 0.60 2.61 2.89 2.7 11.6 12.8 98 3.98 A

1.5+1.5+2.0+2.0+4.2 1.39 1.39 1.86 1.86 3.90 3.76 10.40 11.11 0.64 2.61 2.89 2.8 11.6 12.8 98 3.98 A

1.5+1.5+2.0+2.0+5.0 1.30 1.30 1.73 1.73 4.33 3.99 10.40 11.24 0.66 2.51 2.90 2.9 11.1 12.9 98 4.14 A

1.5+1.5+2.0+2.0+6.0 1.20 1.20 1.60 1.60 4.80 4.27 10.40 11.47 0.67 2.38 2.81 3.0 10.6 12.5 98 4.37 A

1.5+1.5+2.0+2.0+7.1 1.11 1.11 1.48 1.48 5.24 4.58 10.40 11.50 0.71 2.36 2.79 3.1 10.5 12.4 98 4.41 A

1.5+1.5+2.0+2.5+2.5 1.56 1.56 2.08 2.60 2.60 3.42 10.40 11.10 0.58 2.62 2.89 2.6 11.6 12.8 98 3.97 A

1.5+1.5+2.0+2.5+3.5 1.42 1.42 1.89 2.36 3.31 3.70 10.40 11.11 0.62 2.61 2.89 2.8 11.6 12.8 98 3.98 A

1.5+1.5+2.0+2.5+4.2 1.33 1.33 1.78 2.22 3.73 3.90 10.40 11.11 0.66 2.61 2.89 2.9 11.6 12.8 98 3.98 A

1.5+1.5+2.0+2.5+5.0 1.25 1.25 1.66 2.08 4.16 4.13 10.40 11.24 0.69 2.51 2.90 3.1 11.1 12.9 98 4.14 A

1.5+1.5+2.0+2.5+6.0 1.16 1.16 1.54 1.93 4.62 4.41 10.40 11.47 0.69 2.38 2.81 3.1 10.6 12.5 98 4.37 A

1.5+1.5+2.0+2.5+7.1 1.07 1.07 1.42 1.78 5.06 4.72 10.40 11.50 0.76 2.36 2.79 3.4 10.5 12.4 98 4.41 A

1.5+1.5+2.0+3.5+3.5 1.30 1.30 1.73 3.03 3.03 3.99 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+1.5+2.0+3.5+4.2 1.23 1.23 1.64 2.87 3.44 4.18 10.40 11.12 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+1.5+2.0+3.5+5.0 1.16 1.16 1.54 2.70 3.85 4.41 10.40 11.25 0.74 2.51 2.89 3.3 11.1 12.8 98 4.14 A

1.5+1.5+2.0+3.5+6.0 1.08 1.08 1.43 2.51 4.30 4.69 10.40 11.48 0.74 2.37 2.80 3.3 10.5 12.4 98 4.39 A

1.5+1.5+2.0+3.5+7.1 1.00 1.00 1.33 2.33 4.73 5.00 10.40 11.51 0.81 2.36 2.79 3.6 10.5 12.4 98 4.41 A

1.5+1.5+2.0+4.2+4.2 1.16 1.16 1.55 3.26 3.26 4.38 10.40 11.13 0.76 2.60 2.88 3.4 11.5 12.8 98 4.00 A

1.5+1.5+2.0+4.2+5.0 1.10 1.10 1.46 3.08 3.66 4.61 10.40 11.26 0.79 2.50 2.89 3.5 11.1 12.8 98 4.16 A

1.5+1.5+2.0+4.2+6.0 1.03 1.03 1.37 2.87 4.11 4.89 10.40 11.49 0.79 2.37 2.80 3.5 10.5 12.4 98 4.39 A

1.5+1.5+2.0+5.0+5.0 1.04 1.04 1.39 3.47 3.47 4.83 10.40 11.38 0.82 2.46 2.84 3.6 10.9 12.6 98 4.23 A

1.5+1.5+2.5+2.5+2.5 1.49 1.49 2.48 2.48 2.48 3.56 10.40 11.10 0.60 2.62 2.89 2.7 11.6 12.8 98 3.97 A

1.5+1.5+2.5+2.5+3.5 1.36 1.36 2.26 2.26 3.17 3.84 10.40 11.11 0.67 2.61 2.89 3.0 11.6 12.8 98 3.98 A

1.5+1.5+2.5+2.5+4.2 1.28 1.28 2.13 2.13 3.58 4.04 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+1.5+2.5+2.5+5.0 1.20 1.20 2.00 2.00 4.00 4.27 10.40 11.24 0.71 2.51 2.90 3.1 11.1 12.9 98 4.14 A

1.5+1.5+2.5+2.5+6.0 1.11 1.11 1.86 1.86 4.46 4.55 10.40 11.47 0.72 2.38 2.81 3.2 10.6 12.5 98 4.37 A

1.5+1.5+2.5+2.5+7.1 1.03 1.03 1.72 1.72 4.89 4.86 10.40 11.50 0.79 2.36 2.79 3.5 10.5 12.4 98 4.41 A

1.5+1.5+2.5+3.5+3.5 1.25 1.25 2.08 2.91 2.91 4.13 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+1.5+2.5+3.5+4.2 1.18 1.18 1.97 2.76 3.31 4.32 10.40 11.12 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

1.5+1.5+2.5+3.5+5.0 1.11 1.11 1.86 2.60 3.71 4.55 10.40 11.25 0.76 2.51 2.89 3.4 11.1 12.8 98 4.14 A

1.5+1.5+2.5+3.5+6.0 1.04 1.04 1.73 2.43 4.16 4.83 10.40 11.48 0.79 2.37 2.80 3.5 10.5 12.4 98 4.39 A

1.5+1.5+2.5+4.2+4.2 1.12 1.12 1.87 3.14 3.14 4.52 10.40 11.13 0.79 2.60 2.88 3.5 11.5 12.8 98 4.00 A

1.5+1.5+2.5+4.2+5.0 1.06 1.06 1.77 2.97 3.54 4.75 10.40 11.26 0.82 2.50 2.89 3.6 11.1 12.8 98 4.16 A

1.5+1.5+2.5+5.0+5.0 1.01 1.01 1.68 3.35 3.35 4.97 10.40 11.38 0.84 2.46 2.84 3.7 10.9 12.6 98 4.23 A

1.5+1.5+3.5+3.5+3.5 1.16 1.16 2.70 2.70 2.70 4.41 10.40 11.12 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

1.5+1.5+3.5+3.5+4.2 1.10 1.10 2.56 2.56 3.08 4.61 10.40 11.13 0.81 2.60 2.88 3.6 11.5 12.8 98 4.00 A

1.5+1.5+3.5+3.5+5.0 1.04 1.04 2.43 2.43 3.47 4.83 10.40 11.26 0.84 2.50 2.89 3.7 11.1 12.8 98 4.16 A

1.5+1.5+3.5+4.2+4.2 1.05 1.05 2.44 2.93 2.93 4.80 10.40 11.14 0.87 2.60 2.88 3.9 11.5 12.8 98 4.00 A

1.5+2.0+2.0+2.0+2.0 1.63 2.17 2.17 2.17 2.17 3.28 10.31 11.10 0.55 2.56 2.89 2.4 11.4 12.8 98 4.03 A

1.5+2.0+2.0+2.0+2.5 1.56 2.08 2.08 2.08 2.60 3.42 10.40 11.10 0.58 2.62 2.89 2.6 11.6 12.8 98 3.97 A

1.5+2.0+2.0+2.0+3.5 1.42 1.89 1.89 1.89 3.31 3.70 10.40 11.11 0.62 2.61 2.89 2.8 11.6 12.8 98 3.98 A

1.5+2.0+2.0+2.0+4.2 1.33 1.78 1.78 1.78 3.73 3.90 10.40 11.11 0.66 2.61 2.89 2.9 11.6 12.8 98 3.98 A

1.5+2.0+2.0+2.0+5.0 1.25 1.66 1.66 1.66 4.16 4.13 10.40 11.24 0.69 2.51 2.90 3.1 11.1 12.9 98 4.14 A

1.5+2.0+2.0+2.0+6.0 1.16 1.54 1.54 1.54 4.62 4.41 10.40 11.47 0.69 2.38 2.81 3.1 10.6 12.5 98 4.37 A

1.5+2.0+2.0+2.0+7.1 1.07 1.42 1.42 1.42 5.06 4.72 10.40 11.50 0.76 2.36 2.79 3.4 10.5 12.4 98 4.41 A

1.5+2.0+2.0+2.5+2.5 1.49 1.98 1.98 2.48 2.48 3.56 10.40 11.10 0.60 2.62 2.89 2.7 11.6 12.8 98 3.97 A

1.5+2.0+2.0+2.5+3.5 1.36 1.81 1.81 2.26 3.17 3.84 10.40 11.11 0.67 2.61 2.89 3.0 11.6 12.8 98 3.98 A

1.5+2.0+2.0+2.5+4.2 1.28 1.70 1.70 2.13 3.58 4.04 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+2.0+2.0+2.5+5.0 1.20 1.60 1.60 2.00 4.00 4.27 10.40 11.24 0.71 2.51 2.90 3.1 11.1 12.9 98 4.14 A

1.5+2.0+2.0+2.5+6.0 1.11 1.49 1.49 1.86 4.46 4.55 10.40 11.47 0.72 2.38 2.81 3.2 10.6 12.5 98 4.37 A

1.5+2.0+2.0+2.5+7.1 1.03 1.38 1.38 1.72 4.89 4.86 10.40 11.50 0.79 2.36 2.79 3.5 10.5 12.4 98 4.41 A

1.5+2.0+2.0+3.5+3.5 1.25 1.66 1.66 2.91 2.91 4.13 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+2.0+2.0+3.5+4.2 1.18 1.58 1.58 2.76 3.31 4.32 10.40 11.12 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

1.5+2.0+2.0+3.5+5.0 1.11 1.49 1.49 2.60 3.71 4.55 10.40 11.25 0.76 2.51 2.89 3.4 11.1 12.8 98 4.14 A

1.5+2.0+2.0+3.5+6.0 1.04 1.39 1.39 2.43 4.16 4.83 10.40 11.48 0.79 2.37 2.80 3.5 10.5 12.4 98 4.39 A

1.5+2.0+2.0+4.2+4.2 1.12 1.50 1.50 3.14 3.14 4.52 10.40 11.13 0.79 2.60 2.88 3.5 11.5 12.8 98 4.00 A

1.5+2.0+2.0+4.2+5.0 1.06 1.41 1.41 2.97 3.54 4.75 10.40 11.26 0.82 2.50 2.89 3.6 11.1 12.8 98 4.16 A

1.5+2.0+2.0+5.0+5.0 1.01 1.34 1.34 3.35 3.35 4.97 10.40 11.38 0.84 2.46 2.84 3.7 10.9 12.6 98 4.23 A

1.5+2.0+2.5+2.5+2.5 1.42 1.89 2.36 2.36 2.36 3.70 10.40 11.10 0.62 2.62 2.89 2.8 11.6 12.8 98 3.97 A

1.5+2.0+2.5+2.5+3.5 1.30 1.73 2.17 2.17 3.03 3.99 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+2.0+2.5+2.5+4.2 1.23 1.64 2.05 2.05 3.44 4.18 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+2.0+2.5+2.5+5.0 1.16 1.54 1.93 1.93 3.85 4.41 10.40 11.24 0.74 2.51 2.90 3.3 11.1 12.9 98 4.14 A

1.5+2.0+2.5+2.5+6.0 1.08 1.43 1.79 1.79 4.30 4.69 10.40 11.47 0.74 2.38 2.81 3.3 10.6 12.5 98 4.37 A

1.5+2.0+2.5+2.5+7.1 1.00 1.33 1.67 1.67 4.73 5.00 10.40 11.50 0.82 2.36 2.79 3.6 10.5 12.4 98 4.41 A

1.5+2.0+2.5+3.5+3.5 1.20 1.60 2.00 2.80 2.80 4.27 10.40 11.11 0.74 2.61 2.89 3.3 11.6 12.8 98 3.98 A

1.5+2.0+2.5+3.5+4.2 1.14 1.52 1.90 2.66 3.19 4.46 10.40 11.12 0.79 2.61 2.89 3.5 11.6 12.8 98 3.98 A

1.5+2.0+2.5+3.5+5.0 1.08 1.43 1.79 2.51 3.59 4.69 10.40 11.25 0.82 2.51 2.89 3.6 11.1 12.8 98 4.14 A

1.5+2.0+2.5+3.5+6.0 1.01 1.34 1.68 2.35 4.03 4.97 10.40 11.48 0.82 2.37 2.80 3.6 10.5 12.4 98 4.39 A

1.5+2.0+2.5+4.2+4.2 1.08 1.44 1.81 3.03 3.03 4.66 10.40 11.13 0.81 2.60 2.88 3.6 11.5 12.8 98 4.00 A

1.5+2.0+2.5+4.2+5.0 1.03 1.37 1.71 2.87 3.42 4.89 10.40 11.26 0.84 2.50 2.89 3.7 11.1 12.8 98 4.16 A

1.5+2.0+3.5+3.5+3.5 1.11 1.49 2.60 2.60 2.60 4.55 10.40 11.12 0.82 2.61 2.89 3.6 11.6 12.8 98 3.98 A

1.5+2.0+3.5+3.5+4.2 1.06 1.41 2.48 2.48 2.97 4.75 10.40 11.13 0.84 2.60 2.88 3.7 11.5 12.8 98 4.00 A

1.5+2.0+3.5+3.5+5.0 1.01 1.34 2.35 2.35 3.35 4.97 10.40 11.26 0.87 2.50 2.89 3.9 11.1 12.8 98 4.16 A

1.5+2.0+3.5+4.2+4.2 1.01 1.35 2.36 2.84 2.84 4.94 10.40 11.14 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

120

5MXS-E

GC_pre2_lowres.pdf 120 30/11/2011 12:31:12

Page 123: DAIKIN General Catalogue 2012

Combination tables

HEATINGOUTDOOR UNIT INDOOR UNIT

HEATING CAPACITY (kW) TOTAL CAPACITY (kW) POWER INPUT COOLING (kW) TOTAL CURRENT (A) POWER FACTOR

(%)COP

ENERGY LABELA ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.

5MXS90E2V3B

1.5+2.5+2.5+2.5+2.5 1.36 2.26 2.26 2.26 2.26 3.84 10.40 11.10 0.67 2.62 2.89 3.0 11.6 12.8 98 3.97 A

1.5+2.5+2.5+2.5+3.5 1.25 2.08 2.08 2.08 2.91 4.13 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

1.5+2.5+2.5+2.5+4.2 1.18 1.97 1.97 1.97 3.31 4.32 10.40 11.11 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

1.5+2.5+2.5+2.5+5.0 1.11 1.86 1.86 1.86 3.71 4.55 10.40 11.24 0.76 2.51 2.90 3.4 11.1 12.9 98 4.14 A

1.5+2.5+2.5+2.5+6.0 1.04 1.73 1.73 1.73 4.16 4.83 10.40 11.47 0.80 2.38 2.81 3.5 10.6 12.5 98 4.37 A

1.5+2.5+2.5+3.5+3.5 1.16 1.93 1.93 2.70 2.70 4.41 10.40 11.11 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

1.5+2.5+2.5+3.5+4.2 1.10 1.83 1.83 2.56 3.08 4.61 10.40 11.12 0.82 2.61 2.89 3.6 11.6 12.8 98 3.98 A

1.5+2.5+2.5+3.5+5.0 1.04 1.73 1.73 2.43 3.47 4.83 10.40 11.25 0.84 2.51 2.89 3.7 11.1 12.8 98 4.14 A

1.5+2.5+2.5+4.2+4.2 1.05 1.74 1.74 2.93 2.93 4.80 10.40 11.13 0.87 2.60 2.88 3.9 11.5 12.8 98 4.00 A

1.5+2.5+3.5+3.5+3.5 1.08 1.79 2.51 2.51 2.51 4.69 10.40 11.12 0.84 2.61 2.89 3.7 11.6 12.8 98 3.98 A

1.5+2.5+3.5+3.5+4.2 1.03 1.71 2.39 2.39 2.87 4.89 10.40 11.13 0.87 2.60 2.88 3.9 11.5 12.8 98 4.00 A

1.5+3.5+3.5+3.5+3.5 1.01 2.35 2.35 2.35 2.35 4.97 10.40 11.13 0.90 2.60 2.88 4.0 11.5 12.8 98 4.00 A

2.0+2.0+2.0+2.0+2.0 2.08 2.08 2.08 2.08 2.08 3.42 10.40 11.10 0.58 2.62 2.89 2.6 11.6 12.8 98 3.97 A

2.0+2.0+2.0+2.0+2.5 1.98 1.98 1.98 1.98 2.48 3.56 10.40 11.10 0.60 2.62 2.89 2.7 11.6 12.8 98 3.97 A

2.0+2.0+2.0+2.0+3.5 1.81 1.81 1.81 1.81 3.16 3.84 10.40 11.11 0.67 2.61 2.89 3.0 11.6 12.8 98 3.98 A

2.0+2.0+2.0+2.0+4.2 1.70 1.70 1.70 1.70 3.60 4.04 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

2.0+2.0+2.0+2.0+5.0 1.60 1.60 1.60 1.60 4.00 4.27 10.40 11.24 0.71 2.51 2.90 3.1 11.1 12.9 98 4.14 A

2.0+2.0+2.0+2.0+6.0 1.49 1.49 1.49 1.49 4.44 4.55 10.40 11.47 0.72 2.38 2.81 3.2 10.6 12.5 98 4.37 A

2.0+2.0+2.0+2.0+7.1 1.38 1.38 1.38 1.38 4.88 4.86 10.40 11.50 0.79 2.36 2.79 3.5 10.5 12.4 98 4.41 A

2.0+2.0+2.0+2.5+2.5 1.90 1.90 1.90 2.35 2.35 3.70 10.40 11.10 0.62 2.62 2.89 2.8 11.6 12.8 98 3.97 A

2.0+2.0+2.0+2.5+3.5 1.73 1.73 1.73 2.17 3.04 3.99 10.40 11.11 0.69 2.61 2.89 3.1 11.6 12.8 98 3.98 A

2.0+2.0+2.0+2.5+4.2 1.64 1.64 1.64 2.05 3.43 4.18 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

2.0+2.0+2.0+2.5+5.0 1.54 1.54 1.54 1.93 3.85 4.41 10.40 11.24 0.74 2.51 2.90 3.3 11.1 12.9 98 4.14 A

2.0+2.0+2.0+2.5+6.0 1.43 1.43 1.43 1.80 4.31 4.69 10.40 11.47 0.74 2.38 2.81 3.3 10.6 12.5 98 4.37 A

2.0+2.0+2.0+2.5+7.1 1.33 1.33 1.33 1.67 4.74 5.00 10.40 11.50 0.82 2.36 2.79 3.6 10.5 12.4 98 4.41 A

2.0+2.0+2.0+3.5+3.5 1.90 1.90 1.90 2.35 2.35 3.70 10.40 11.10 0.62 2.62 2.89 2.8 11.6 12.8 98 3.97 A

2.0+2.0+2.0+3.5+4.2 1.52 1.52 1.52 2.66 3.18 4.46 10.40 11.12 0.79 2.55 2.89 3.5 11.3 12.8 98 4.08 A

2.0+2.0+2.0+3.5+5.0 1.43 1.43 1.43 2.51 3.60 4.69 10.40 11.25 0.82 2.51 2.89 3.6 11.1 12.8 98 4.14 A

2.0+2.0+2.0+3.5+6.0 1.34 1.34 1.34 2.35 4.03 4.97 10.40 11.48 0.82 2.37 2.80 3.6 10.5 12.4 98 4.39 A

2.0+2.0+2.0+4.2+4.2 1.44 1.44 1.44 3.04 3.04 4.66 10.40 11.13 0.81 2.55 2.88 3.6 11.3 12.8 98 4.08 A

2.0+2.0+2.0+4.2+5.0 1.37 1.37 1.37 2.87 3.42 4.89 10.40 11.26 0.84 2.56 2.95 3.7 11.4 13.1 98 4.06 A

2.0+2.0+2.5+2.5+2.5 1.81 1.81 2.26 2.26 2.26 3.84 10.40 11.10 0.67 2.62 2.89 3.0 11.6 12.8 98 3.97 A

2.0+2.0+2.5+2.5+3.5 1.66 1.66 2.08 2.08 2.92 4.13 10.40 11.11 0.71 2.61 2.89 3.1 11.6 12.8 98 3.98 A

2.0+2.0+2.5+2.5+4.2 1.58 1.58 1.97 1.97 3.30 4.32 10.40 11.11 0.74 2.56 2.89 3.3 11.4 12.8 98 4.06 A

2.0+2.0+2.5+2.5+5.0 1.49 1.49 1.86 1.86 3.70 4.55 10.40 11.24 0.76 2.51 2.90 3.4 11.1 12.9 98 4.14 A

2.0+2.0+2.5+2.5+6.0 1.39 1.39 1.73 1.73 4.16 4.83 10.40 11.47 0.80 2.38 2.81 3.5 10.6 12.5 98 4.37 A

2.0+2.0+2.5+3.5+3.5 1.54 1.54 1.92 2.70 2.70 4.41 10.40 11.11 0.76 2.61 2.89 3.4 11.6 12.8 98 3.98 A

2.0+2.0+2.5+3.5+4.2 1.46 1.46 1.84 2.56 3.08 4.61 10.40 11.12 0.82 2.55 2.89 3.6 11.3 12.8 98 4.08 A

2.0+2.0+2.5+3.5+5.0 1.39 1.39 1.72 2.43 3.47 4.83 10.40 11.25 0.84 2.51 2.89 3.7 11.1 12.8 98 4.14 A

2.0+2.0+2.5+4.2+4.2 1.40 1.40 1.74 2.93 2.93 4.80 10.40 11.13 0.87 2.60 2.94 3.9 11.5 13.0 98 4.00 A

2.0+2.0+3.5+3.5+3.5 1.44 1.44 2.52 2.50 2.50 4.69 10.40 11.12 0.84 2.61 2.89 3.7 11.6 12.8 98 3.98 A

2.0+2.0+3.5+3.5+4.2 1.37 1.37 2.40 2.39 2.87 4.89 10.40 11.13 0.87 2.60 2.94 3.9 11.5 13.0 98 4.00 A

2.0+2.5+2.5+2.5+2.5 1.72 2.17 2.17 2.17 2.17 3.99 10.40 11.10 0.69 2.62 2.89 3.1 11.6 12.8 98 3.97 A

2.0+2.5+2.5+2.5+3.5 1.60 2.00 2.00 2.00 2.80 4.27 10.40 11.11 0.74 2.61 2.89 3.3 11.6 12.8 98 3.98 A

2.0+2.5+2.5+2.5+4.2 1.52 1.90 1.90 1.90 3.18 4.46 10.40 11.11 0.79 2.56 2.89 3.5 11.4 12.8 98 4.06 A

2.0+2.5+2.5+2.5+5.0 1.44 1.79 1.79 1.79 3.59 4.69 10.40 11.24 0.82 2.51 2.90 3.6 11.1 12.9 98 4.14 A

2.0+2.5+2.5+2.5+6.0 1.33 1.68 1.68 1.68 4.03 4.97 10.40 11.47 0.82 2.38 2.81 3.6 10.6 12.5 98 4.37 A

2.0+2.5+2.5+3.5+3.5 1.48 1.86 1.86 2.60 2.60 4.55 10.40 11.11 0.82 2.61 2.89 3.6 11.6 12.8 98 3.98 A

2.0+2.5+2.5+3.5+4.2 1.41 1.77 1.77 2.48 2.97 4.75 10.40 11.12 0.84 2.55 2.89 3.7 11.3 12.8 98 4.08 A

2.0+2.5+2.5+3.5+5.0 1.34 1.68 1.68 2.35 3.35 4.97 10.40 11.25 0.87 2.51 2.89 3.9 11.1 12.8 98 4.14 A

2.0+2.5+2.5+4.2+4.2 1.34 1.69 1.69 2.84 2.84 4.94 10.40 11.13 0.90 2.60 2.94 4.0 11.5 13.0 98 4.00 A

2.0+2.5+3.5+3.5+3.5 1.38 1.73 2.43 2.43 2.43 4.83 10.40 11.12 0.87 2.61 2.89 3.9 11.6 12.8 98 3.98 A

2.5+2.5+2.5+2.5+2.5 2.08 2.08 2.08 2.08 2.08 4.13 10.40 11.10 0.72 2.62 2.89 3.2 11.6 12.8 98 3.97 A

2.5+2.5+2.5+2.5+3.5 1.93 1.93 1.93 1.93 2.68 4.41 10.40 11.11 0.77 2.61 2.89 3.4 11.6 12.8 98 3.98 A

2.5+2.5+2.5+2.5+4.2 1.83 1.83 1.83 1.83 3.08 4.61 10.40 11.11 0.82 2.56 2.89 3.6 11.4 12.8 98 4.06 A

2.5+2.5+2.5+2.5+5.0 1.73 1.73 1.73 1.73 3.48 4.83 10.40 11.24 0.85 2.51 2.90 3.8 11.1 12.9 98 4.14 A

2.5+2.5+2.5+3.5+3.5 1.80 1.80 1.80 2.50 2.50 4.69 10.40 11.11 0.85 2.61 2.89 3.8 11.6 12.8 98 3.98 A

2.5+2.5+2.5+3.5+4.2 1.71 1.71 1.71 2.40 2.87 4.89 10.40 11.12 0.87 2.61 2.89 3.9 11.6 12.8 98 3.98 A

2.5+2.5+3.5+3.5+3.5 1.69 1.69 2.34 2.34 2.34 4.97 10.40 11.12 0.90 2.61 2.89 4.0 11.6 12.8 98 3.98 A

Notes: 1. Cooling capacity is based on 27°CDB/19°CWB (Indoor temperature). 35°CDB (Outdoor temperature). Heating capacity is based on 20°CDB (Indoor temperature). 7°CDB/6°CWB (Outdoor temperature). 2. The total ability of connected a indoor unit is up to 14.5kW. 3. It is impossible to connect the indoor unit for one room only. 4. The above is the value for connecting with the following indoor units. 1.5. 2.0. 2.5. 3.5 kW class; wall mounted K series 4.2. 5.0 kW class; wall mounted J series 6.0. 7.1 kW class; wall mounted G series

* This page contains preliminary data

121

5MXS-E

GC_pre2_lowres.pdf 121 30/11/2011 12:31:13

Page 124: DAIKIN General Catalogue 2012

122

GC_pre2_lowres.pdf 122 30/11/2011 12:31:13

Page 125: DAIKIN General Catalogue 2012

123

VRVIII-S heat pump for residential application

› Energy efficient heating system based on air source heat pump technology › Low energy bills and low CO

2 emissions

› Possibility to connect up to 9 indoor units › All indoor units can be individually controlled and do not need

to be installed in the same room or even at the same time › Possibility to combine different types of indoor units:

wall mounted, floor standing, concealed ceiling, ceiling suspended units, round flow or 4-way blow cassettes

› Slim design for flexible installation › 3 steps in night quiet mode: step 1: 47dBA, step 2: 44 dBA, step 3: 41 dBA › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Possibility to limit peak power consumption between 30 and

80%, for example during periods with high power demand

Heating & Cooling

CONNECTABLE INDOOR UNITS

Wall mounted Floor standing Concealed ceiling Flexi typeRound flow

cassette4-way blow

cassetteCeiling

suspended

FTXG-J CTXS-K FTXS-K FTXS-J/G FVXG-K FVXS-F FDBQ-B FDXS-E FDXS-C FBQ-C FLXS-B FCQG-F FFQ-B9V FHQ-B

25 35 50 15 35 20 25 25 35 42 50 60 71 25 35 50 25 35 50 25 25 35 50 60 35 50 60 25 35 50 60 35 50 60 25 35 50 60 35 50 60

RXYSQ-P8V1 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Brushed aluminium

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Matt crystal white

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

123

FTXG25JA FTXG35JA FTXG50JA

295x915x155

11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1

54 58 60

55 58 60

38/32/25/22 42/34/26/23 44/40/35/32

39/34/28/25 42/36/29/26 44/40/35/32

6.35

9.52 12.7

18

FTXG25JW FTXG35JW FTXG50JW

295x915x155

11

8.8/6.8/4.7/3.8 10.1/7.3/4.6/3.9 10.3/8.5/6.7/5.7

9.6/7.9/6.2/5.4 10.8/8.6/6.4/5.6 11.4/9.8/8.1/7.1

54 58 60

55 58 60

38/32/25/22 42/34/26/23 44/40/35/32

39/34/28/25 42/36/29/26 44/40/35/32

6.35

9.52 12.70

18

123

RXYSQ-P8V1

GC_pre2_lowres.pdf 123 30/11/2011 12:31:14

Page 126: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High m³/min

Heating High m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections Liquid OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling Nom. dBA

Heating Nom. dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation/Radiant heat dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

VRVIII-S heat pump for residential application

FTXS20K FTXS25K CTXS15K CTXS35K

289x780x215 289x780x215

8 8

8.8/6.7/4.7/3.9 9.1/7.0/5.0/3.9 7.9/6.3/4.7/3.9 9.0/7.5/6.0/4.3

9.5/7.8/6.0/4.3 10.0/8.0/6.0/4.3 9.2/7.2/5.2/3.9 10.1/8.1/6.3/4.3

56 57 53 58

56 57 54 57

40/32/24/19 41/33/25/19 37/31/25/21 42/35/28/21

40/34/27/19 41/34/27/19 38/33/28/21 41/36/30/21

R-410A R-410A

6.35 6.35

9.52 9.52

18.0 18.0

1~ / 50 / 220-240 1~ / 50 / 220-240

FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G

290x1,050x250

10 12

11.4/8.7/5.8/4.4 11.3/9.0/6.8/5.9 11.6/9.2/7.0/6.0 16.0/13.5/11.3/10.1 17.2/14.5/11.5/10.5

12.4/9.5/6.8/6.0 12.2/9.7/7.3/6.4 12.1/9.8/7.6/6.7 17.2/14.9/12.6/11.3 19.5/16.7/14.2/12.6

61 62 61 62

61 63 60 62

45/37/29/23 45/39/33/30 46/40/34/31 45/41/36/33 46/42/37/34

45/39/29/26 45/39/33/30 47/41/34/31 44/40/35/32 46/42/37/34

12.7 15.9

18.0

FTX20JV FTX25JV FTX35JV

283x770x198

7

9.1/7.4/5.9/4.7 9.2/7.6/6.0/4.8 9.3/7.7/6.1/4.9

9.4/7.8/6.3/5.5 9.7/8.0/6.3/5.5 10.1/8.4/6.7/5.7

55 56 57

55 56 57

39/33/25/22 40/33/26/22 41/34/27/23

39/34/28/25 40/34/28/25 41/35/29/26

6.35

FVXG25K FVXG35K FVXG50K

600x950x215

22

8.9/7.0/5.3/4.5 9.1/7.2/5.3/4.5 10.6/8.9/7.3/6.0

9.9/7.8/5.7/4.7 10.2/8.0/5.8/5.0 12.2/10.0/7.8/6.8

54 55 56

55 56 58

38/32/26/23 39/33/27/24 44/40/36/32

39/32/26/22/19 40/33/27/23/19 46/40/34/30/20

6.35

9.50 12.70

18

1~ / 50 / 220-240

124

RXYSQ-P8V1

GC_pre2_lowres.pdf 124 30/11/2011 12:31:14

Page 127: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Fan - External static pressure Nom. Pa

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP20 (I.D. 20/O.D. 26)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Almond white

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220-230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Low dBA

Heating High/Low dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

VRVIII-S heat pump for residential application

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

FDXS25E FDXS35E FDXS50C FDXS60C

200x700x620 200x900x620 200x1,100x620

21.0 27.0 30.0

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

8.7/8.0/7.3/6.2 12.0/11.0/10.0/8.4 16.0/14.8/13.5/11.2

30 40

53.0 55.0 56.0

53.0 55.0 56.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

35.0/33.0/31.0/29.0 37.0/35.0/33.0/31.0 38.0/36.0/34.0/32.0

6.35

9.52 12.7

FLXS25B FLXS35B FLXS50B FLXS60B

490x1,050x200

16 17

7.6/6.8/6.0/5.2 8.6/7.6/6.6/5.6 11.4/10.0/8.5/7.5 12.0/10.7/9.3/8.3

9.2/8.3/7.4/6.6 9.8/8.9/8.0/7.2 12.1/9.8/7.5/6.8 12.8/10.6/8.4/7.5

53 54 63 64

53 55 62 63

37/34/31/28 38/35/32/29 47/43/39/36 48/45/41/39

37/34/31/29 39/36/33/30 46/41/35/33 47/42/37/34

6.35

9.52 12.7

18

FDBQ25B

230x652x502

17.0

6.50/5.20

6.95/5.20

55.0/49.0

55.0/49.0

35.0/28.0

35.0/29.0

6.35

9.52

27.2

FVXS25F FVXS35F FVXS50F

600x700x210

14

8.2/6.5/4.8/4.1 8.5/6.7/4.9/4.5 10.7/9.2/7.8/6.6

8.8/6.9/5.0/4.4 9.4/7.3/5.2/4.7 11.8/10.1/8.5/7.1

54 55 56

54 55 57

38/32/26/23 39/33/27/24 44/40/36/32

38/32/26/23 39/33/27/24 45/40/36/32

6.35

9.52 12.7

20

125

RXYSQ-P8V1

GC_pre2_lowres.pdf 125 30/11/2011 12:31:14

Page 128: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS45DJW1 BYBS71DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Fan - External static pressure High/Nom. Pa

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP25 (O.D. 32 / I.D. 25)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor units *FCQG35F *FCQG50F *FCQG60F

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYFQ60BAW1

Colour White

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

VRVIII-S heat pump for residential application

2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel*Note: grey cells contain preliminary data

FBQ35C8 FBQ50C8 FBQ60C8

300x700x700 300x1,000x700

350

25 34

55x800x500 55x1,100x500

3.5 4.5

16/11 18/15

16/11 18/15

100/30

63 57

-

37/29

37/29

6.35

9.52 12.70

204x840x840

19

BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

-

-

-

R-410A

-

-

-

1~ / 50/60 / 220-240/220

FFQ25B9V FFQ35B9V FFQ50B9V FFQ60B9V

-

286x575x575

17.5

55x700x700

2.7

9.0/-/6.5/- 10.0/-/6.5/- 12.0/-/8.0/- 15.0/-/10.0/-

9.0/-/6.5/- 10.0/-/6.5/- 12.0/-/8.0/- 15.0/-/10.0/-

46.5 49.0 53.0 58.0

-

29.5/-/24.5/- 32.0/-/25.0/- 36.0/-/27.0/- 41.0/-/32.0/-

29.5/-/24.5/- 32.0/-/25.0/- 36.0/-/27.0/- 41.0/-/32.0/-

6.35

9.52 12.7

26

126

RXYSQ-P8V1

GC_pre2_lowres.pdf 126 30/11/2011 12:31:14

Page 129: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low/Silent operation m³/min

Heating High/Nom./Low/Silent operation m³/min

Sound power level Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP20 (I.D. 20/O.D. 26)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE OUTDOOR UNITS

Outdoor unit

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 40 (Outdoor unit in highest position) / 30 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Branch provider BPMKS967B2 BPMKS967B3

Connectable indoor units

Max. indoor unit connectable capacity

Max. connectable combination

Dimensions Height x Width x Depth mm

Weight kg

VRVIII-S heat pump for residential application

FHQ35B FHQ50B FHQ60B

195x960x680 195x1,160x680

24 25 27

13/-/10/- 17/-/13/-

13/-/10/- 16/-/13/-

53/-/48 54/-/49 55/-/49

53/-/48 54/-/49 55/-/49

37/-/32/- 38/-/33/- 39/-/33/-

37/-/32/- 38/-/33/- 39/-/33/-

6.35

9.52 12.70

RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1

4 5 6

11.2 14.0 15.5

12.5 16.0 18.0

2.81 3.51 4.53

2.74 3.86 4.57

3.99 3.99 3.42

4.56 4.15 3.94

6 8 9

1,345x900x320

120

66 67 69

50 51 53

52 53 55

-5~46

-20~15.5

9.52

19.1

150

115 135 145

1N~/50/220-240

32.0

1~2 1~3

14.2 20.8

71+71 60+71+71

180x294x350

7 8

127

RXYSQ-P8V1

GC_pre2_lowres.pdf 127 30/11/2011 12:31:15

Page 130: DAIKIN General Catalogue 2012

Know the TRUE COLOURS of your energy bill......and prepare for a monumental change.

Seasonal effi ciency is a new energy effi ciency measure that will be the standard as of 2013.y

A true monumental change. Products optimised for seasonal effi ciency consume less energy

and put less burden on the environment. And on your wallet. At Daikin we already go sea-

sonal today. That is why we are the fi rst in the industry to launch products optimized for

seasonal effi ciency. The seasonal performance values of our products.

Energy effi ciency is no longer a blind spot. Find out more on www.daikin.eu

GC_pre2_lowres.pdf 128 30/11/2011 12:31:15

Page 131: DAIKIN General Catalogue 2012

��

LIGHT COMMERCIAL APPLICATIONS

Benefits overview 130

Seasonal efficiency 132

PAIR APPLICATIONS

Cassette Units

FCQHG-F / RZQG-L 136

FCQHG-F / RZQSG-L 137

FCQG-F / RZQG-L 138

FCQG-F / RZQSG-L 139

FCQG-F / RXS-J/F 140

FFQ-B9V / RXS-K/J/F 141

Concealed Ceiling Units 142

FBQ-C / RZQG-L 142

FBQ-C / RZQSG-L 143

FBQ-C / RXS-J/F 144

FDQ-B / RZQ-C 145

FDQ-C / RZQG-L 146

FDQ-C / RZQSG-L 147

Wall Mounted Units 148

FAQ-C / RZQG-L 149

FAQ-C / RZQSG-L 149

Ceiling Suspended Units 150

FHQG-C / RZQG-L 150

FHQG-C / RZQSG-L 151

FHQ-B / RXS-J/F 152

FUQ-B / RZQG-L 153

Floor Standing Unit 154

FVQ-C / RZQG-L 154

FVQ-C / RZQSG-L 155

SIESTA SKY AIR

4-Way Blow Ceiling Mounted Cassette

ACQ-A / AZQS-A 156

Concealed Ceiling Units 157

ABQ-A / AZQS-A 157

Ceiling Suspended Units 158

AHQ-A / AZQS-A 158

COMMERCIAL MULTI SYSTEM 160

CMSQ-A 160

TWIN, TRIPLE,

DOUBLE TWIN APPLICATIONS 162

RZQG-L 162

RZQSG-L 165

RZQ-C 167

ROOFTOP 172

UATYQ-CY1 172

UATYP-AY1 172

For more information on Options & Control Systems, please refer to page 332 of this catalogue.

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

GC_pre2_lowres.pdf 129 30/11/2011 12:31:15

Page 132: DAIKIN General Catalogue 2012

We care icons Comfort Air treatment

Ce

ilin

g m

ou

nte

d c

asse

tte

FCQHG-F � � � � � � � � � �

FCQG-F � � � � � � � � � �

FMCQ-A8 � � � � � � � �

FFQ-B9V � � � � � � � �

ACQ-A � � � �

Co

nce

ale

d c

eili

ng

un

it

FBQ-C8 � � � � � � �

FMDQ-B � � � � � �

FDQ-B � � � � � �

FDQ-C � � � � � � �

ABQ-A � � � � �

Ce

ilin

g

susp

en

de

d u

nit

FHQG-C � � � � � �

FHQ-B � � � � �

AHQ-A � � �

4-W

ay b

low

ce

ilin

g

susp

en

de

d

FUQ-B � � � � � � �

Wal

l m

ou

nte

d

FAQ-C � � � � � �

Flo

or

stan

din

g

FVQ-C � � � � �

Benefi ts overview -

For explanation on the benefi ts, see fl ap in the backcover of this catalogue.

��������

130

GC_pre2_lowres.pdf 130 30/11/2011 12:31:15

Page 133: DAIKIN General Catalogue 2012

Other funtionsRemote control & timerAir flowHumidity control

� � � 2 � � � � � �

� � � 2 � � � � � � �

� � � 2 � � � � � � �

� � � 2 � � � � � � � � � �

� 3 � � � � � � � � � �

� 10 (50 class)8 (60~125 class) � � � � � � �

2 � � � � � �

3 � � � � � � �

� 2 � � � � �

� 2 � � � � � � � � � �

� � 2 � � � � � � � �

� � 2 � � � � � � � �

� � � � � �*Note: grey cells contain preliminary data

131

GC_pre2_lowres.pdf 131 30/11/2011 12:31:15

Page 134: DAIKIN General Catalogue 2012

RZQG-RZQGS Seasonal efficiency

The EU requires objective performance metrics to establish the minimum requirements that must be met, and to provide customers with

information on air conditioner performance on which to base their choice. The current methodology – nominal efficiency (EER) – results

in a significant gap between announced and actual performance and so a more accurate method – seasonal efficiency (SEER) – has been

developed. The major changes include the integration of several rating temperatures for cooling and heating, the inclusion of energy use

at part-load as well as full-load and the power used in auxiliary and standby modes. Since most systems operate under a partial load the

majority of the time, the new methodology gives a better indication of expected real-life performance.

Measuring real-life performance

With its 20/20/20 energy policy, Europe is seeking 20% less CO2

produced, 20% more renewable energy used and 20% less primary energy consumed by 2020. To help achieve these targets it has issued the

Energy Related Products Directive which specifies minimum eco-design requirements, such as improved energy efficiency, that must

be integrated into energy-using products. For air conditioners below 12kW, the minimum requirements will be based on a new seasonal

efficiency ratio and Daikin Europe N.V. has already integrated these improvements into the new Sky Air range of light commercial

applications, thus underling our commitment to reducing environmental impact.

European action plan

CO2 EMISSIONS

vs. 1990

Share of

RENEWABLE ENERGY

PRIMARY ENERGY USE

vs. BAU*

By the year

2020*Business As Usual

Nominal versus Seasonal efficiency

1 Temperature

condition:35°C for cooling

7°C for heating

Does not often occur

in reality

NOMINAL SEASONAL

Several rating

temperatures

for cooling and heating,

reflecting actual

performance over an

entire season

Temperature

NOMINAL SEASONAL

Does not reflect

partial capacity

Benefits of inverter technology not visible

Integrates operation at

partial instead of full

capacity

Benefits of inverter

technology are shown

Capacity

NOMINAL SEASONAL

Does not take auxiliary

power modes into account

Includes consumption

auxiliary modes:

• Thermostat off• Standby mode

• OFF mode

• Crankcase heater

Auxiliary modes

Nominal efficiency gives an indication of how efficiently an air

conditioner operates in nominal conditions.

Seasonal efficiency gives an indication of how efficiently an air conditioner operates over an entire cooling or heating season.

Daikin leads the way to seasonal efficiencyintroducing a full light commercial range optimised for seasonal efficiency!

132132

C02

-20% +20% -20%

CAPACITY

10

20 3

0 40 50 60 70 80 90 100

GC_pre2_lowres.pdf 132 30/11/2011 12:31:16

Page 135: DAIKIN General Catalogue 2012

Daikin prides itself on products with high environmental performance. In

2010, well before the Eco-Design deadlines, Daikin introduced the Sky Air

Seasonal Inverter and the pioneering development of this range continues

with the new RZQG-L (Seasonal Smart) and RZQSG-L (Seasonal Classic) series,

with their excellent seasonal efficiency results. This means we now offer a

complete light commercial range of products!

Daikin leads the way: Seasonal series

FCQHG / FCQG FFQ FHQG FBQ FDQ FAQ FVQ FUQ

RZQG-L 120 / 122 146 134 126 130 132 138 137

RZQSG-L 121 / 123 149 135 127 131 133 139

The optimised inverter control over the full temperature

distribution curve provides optimum partial load performance,

giving it high ratings in real-life operating conditions, while the

re-designed compressor and heat exchanger plus improved

auxiliary modes further enhance its performance. Thanks to this

new design, Sky Air RZQG-L outdoor units boast average seasonal

efficiency improvements of more than 20% over the current Sky

Air Seasonal Inverter, and of more than 50% compared to non-

inverter systems.

In addition to its high seasonal performance, the new Sky Air

seasonal series includes benefits such as a wide operating range,

ability to re-use existing piping, and a quiet night mode and it is

totally compatible with our new designs of Sky Air indoor units:

› round flow cassette (FCQG/FCQHG) NEW

› ceiling suspended cassette (FHQG)

› floor standing model (FVQ) NEW

› wall mounted unit (FAQ) NEW

› concealed ceiling unit (FBQ/FDQ) NEW

› 4-way blow ceiling suspended cassette (FUQ)

So what’s new?

Daikin offers now a complete light commercial range, optimised for seasonal efficiency!

RZQG-RZQGS Seasonal efficiency

133

GC_pre2_lowres.pdf 133 30/11/2011 12:31:16

Page 136: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 134 30/11/2011 12:31:16

Page 137: DAIKIN General Catalogue 2012

135

1717 2020

9000

8000

7000

6000

5000

4000

3000

2000

1000

0

Round flow cassette

Next generation

round flow cassette, setting the standard for efficiency and comfort

The round flow cassette is designed for use in all forms and

sizes of commercial offices, retail spaces, restaurants, hotels

and other applications. Today, Daikin has improved its

technology even further to enhance your comfort

and provide you better energy efficient models.

With a new infrared presence and floor sensor Daikin offers

you the best solution for your application.

… and improved comfort• With the optional floor sensor having cold feet becomes history. This sensor detects the average floor temperature and

ensures even temperature distribution between ceiling and floor.

• The presence sensor directs air flow away from any person to avoid draught.

• The unique 360° air flow discharge pattern ensures a uniform temperature distribution across

the room without dead corners.

Flexibility• When refurbishing or rearranging the interior of your office, shop or other area,

you no longer need to change the location of your indoor unit.

With the round flow cassette one or more flaps can be easily closed via

the wired remote controller (BRC1E52A – optional).

Even more energy efficient…• The optional presence sensor adjusts the set point or switches off the unit when there is nobody in the room. Up to 27%

energy can be saved with this new function.

• Daikin was the first to launch an auto cleaning decoration panel. With this panel the costs can be further reduced

as the filter cleans itself automatically once a day. Up to 50% energy can be saved thanks to daily filter cleaning (Wolverhampton, UK)

infrared presence sensor

infrared floor sensor

May

June

July

August

Septem

ber

Octo

ber

November

December

January

Febru

ary

Marc

hJu

lyApril

Auto cleaning cassetteStandard round flow cassette

Cumulative energy comparison over 12 monthsEnergy consumption

(kWh)

GC_pre2_lowres.pdf 135 30/11/2011 12:31:16

Page 138: DAIKIN General Catalogue 2012

136

High COP, round flow cassette

*Note: grey cells contain preliminary data2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel*prEN14825 (inquiry version 2010)

› Seasonal effi ciency, optimized for all seasons › Seasonal effi ciency gives an indication on how effi cient air conditioners operate over an entire heating or cooling season. › High COP round fl ow cassette: ensures top performance. › The round fl ow cassette provides a more comfortable environment and off ers greater

savings in energy consumption to shop, offi ce and restaurant owners. › The unique 360° air discharge ensures uniform air fl ow and temperature distribution › The infrared presence sensor (optional) adjusts the set point with 2°C if no one is detected in the

room. It also automatically directs air fl ow away from any person to avoid draught. › The infrared fl oor sensor (optional) detects the average fl oor temperature and ensures even

temperature distribution between ceiling and fl oor. Cold feet will become history. › Individual fl ap control: one or more fl aps can be easily closed via the wired remote

controller (BRC1E52) when refurbishing or rearranging your interior › Modern style decoration panel is available in 3 diff erent variations: standard panel in white (RAL9010) with grey louvers and

standard panel in full white (RAL9010) including white louvers, auto cleaning panel in white (RAL9010) with grey louvers › For auto cleaning panel (BYCQ140DG):

» Daikin introduces fi rst auto cleaning cassette to European market » Higher effi ciency and comfort from daily auto cleaning of the fi lter » Lower maintenance costs thanks to auto cleaning function » Easy removal of dust with a vacuum cleaner without opening the unit

› No optional adapter needed for DIII-connection

Preliminary

Heating & CoolingIndoor unit *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 4.09 4.42 4.00 3.35 4.09 4.42 4.00 3.35

COP 4.80 4.99 4.40 4.12 4.80 4.99 4.40 4.12

SEER* 6.11 6.21 6.00 To be confi rmed

6.11 6.21 6.00 To be confi rmedSCOP 4.18 4.30 3.89 4.18 4.30 3.89

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/A

Casing Colour To be confi rmed To be confi rmed

Dimensions Unit HeightxWidthxDepth mm 288x840x840 288x840x840

Weight Unit kg 25 25

Decoration panel Model BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14 BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14

Colour Pure White (RAL 9010) Pure White (RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5 5.5 / 5.5 / 11.5

Fan - Air fl ow rate Cooling High/Nom./Low m³/min

To be confi rmed To be confi rmedHeating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low dBA 36/33/29 44/39/33 45/41/35 45/41/37 36/33/29 44/39/33 45/41/35 45/41/37

Heating High/Nom./Low dBA 36/33/29 44/39/33 45/41/35 45/41/37 36/33/29 44/39/33 45/41/35 45/41/37

Refrigerant Type

To be confi rmed To be confi rmedPiping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQG71L7V1B *RZQG100L7V1B *RZQG125L7V1B *RZQG140L7V1B *RZQG71L7Y1B *RZQG100L7Y1B *RZQG125L7Y1B *RZQG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 68 64 66 67 68

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

136136

FCQHG-F / RZQG-LV1/Y1

Seasonal Smart

BRC1E52A BRC7F532FFCQHG100,125,140F RZQG100,125,140LV1/Y1

GC_pre2_lowres.pdf 136 30/11/2011 12:31:17

Page 139: DAIKIN General Catalogue 2012

137

*Note: grey cells contain preliminary data2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.50 3.70 3.23 3.21 3.50 3.70 3.23 3.21

COP 4.10 4.30 3.75 3.61 4.10 4.30 3.75 3.61

SEER* 5.70 5.21 To be confirmed

5.70 5.21 To be confirmedSCOP 3.95 3.91 3.81 3.95 3.91 3.81

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A A/A

Casing Colour To be confirmed To be confirmed

Dimensions Unit HeightxWidthxDepth mm 288x840x840 288x840x840

Weight Unit kg 25 25

Decoration panel Model BYCQ140DW1 / BYCQ140DW1W3 / BYCQ140DGW14 BYCQ140DW1 / BYCQ140DW1W3 / BYCQ140DGW14

Colour Pure White (RAL 9010) Pure White (RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5 5.5 / 5.5 / 11.5

Fan - Air flow rate Cooling High/Nom./Low m³/min

To be confirmed To be confirmedHeating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low dBA 36/33/29 44/39/33 45/41/35 45/41/37 36/33/29 44/39/33 45/41/35 45/41/37

Heating High/Nom./Low dBA 36/33/29 44/39/33 45/41/35 45/41/37 36/33/29 44/39/33 45/41/35 45/41/37

Refrigerant Type

To be confirmed To be confirmedPiping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQSG71L7V1B *RZQSG100L7V1B *RZQSG125L7V1B *RZQSG140L7V1B *RZQSG71L7Y1B *RZQSG100L7Y1B *RZQSG125L7Y1B *RZQSG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 770x900x320 990x940x320 1,430x940x320

Weight Unit kg 68 77 99 68 77 99

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

137137

FCQHG-F / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 137 30/11/2011 12:31:17

Page 140: DAIKIN General Catalogue 2012

138

High COP Round flow cassette

*Note: grey cells contain preliminary data2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel*prEN14825 (inquiry version 2010)

› Seasonal effi ciency, optimized for all seasons › Seasonal effi ciency gives an indication on how effi cient air conditioners operate over an entire heating or cooling season. › High COP round fl ow cassette ensures top performance › The round fl ow cassette provides a more comfortable environment and off ers greater

savings in energy consumption to shop, offi ce and restaurant owners. › The unique 360° air discharge ensures uniform air fl ow and temperature distribution › The infrared presence sensor (optional) adjusts the set point with 2°C if no one is detected in the

room. It also automatically directs air fl ow away from any person to avoid draught. › The infrared fl oor sensor (optional) detects the average fl oor temperature and ensures even

temperature distribution between ceiling and fl oor. Cold feet will become history. › Individual fl ap control: one or more fl aps can be easily closed via the wired remote

controller (BRC1E52A) when refurbishing or rearranging your interior › Modern style decoration panel is available in 3 diff erent variations: standard panel in white (RAL9010) with grey louvers and

standard panel in full white (RAL9010) including white louvers, auto cleaning panel in white (RAL9010) with grey louvers › For auto cleaning panel (BYCQ140DG):

» Daikin introduces fi rst auto cleaning cassette to European market » Higher effi ciency and comfort from daily auto cleaning of the fi lter » Lower maintenance costs thanks to auto cleaning function » Easy removal of dust with a vacuum cleaner without opening the unit

› No optional adapter needed for DIII-connection

Preliminary

Heating & CoolingIndoor unit *FCQG71F *FCQG100F *FCQG125F *FCQG140F *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.39 3.87 3.73 3.21 3.39 3.87 3.73 3.21

COP 3.97 4.15 3.63 3.61 3.97 4.15 3.63 3.61

SEER* 5.81 5.99 5.69 To be confi rmed

5.81 5.99 5.69 To be confi rmedSCOP 4.13 3.93 3.84 4.13 3.93 3.84

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/A

Casing Colour To be confi rmed To be confi rmed

Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840

Weight Unit kg To be confi rmed To be confi rmed

Decoration panel Model BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14 BYCQ140DW1

Colour Pure White (RAL 9010) Pure White (RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5 5.5 / 5.5 / 11.5

Fan - Air fl ow rate Cooling High/Nom./Low m³/minTo be confi rmed

27.5/-/19.0To be confi rmed

27.5/-/19.0

Heating High/Nom./Low m³/min 27.5/-/19.0 27.5/-/19.0

Sound power level Cooling High/Nom./Low dBA To be confi rmed To be confi rmed

Sound pressure level

Cooling High/Nom./Low dBA 33/31/28 37/35/32 41/38/35 33/31/28 37/35/32 41/38/35

Heating High/Nom./Low dBA 33/31/28 37/35/32 41/38/35 33/31/28 37/35/32 41/38/35

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mmTo be confi rmed To be confi rmed

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQG71L7V1B *RZQG100L7V1B *RZQG125L7V1B *RZQG140L7V1B *RZQG71L7Y1B *RZQG100L7Y1B *RZQG125L7Y1B *RZQG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 68 64 66 67 68

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

138138

FCQG-F / RZQG-LV1/Y1

Seasonal Smart

FCQG100,125,140F BRC1E52A BRC7F532FRZQG100,125,140LV1/Y1

GC_pre2_lowres.pdf 138 30/11/2011 12:31:17

Page 141: DAIKIN General Catalogue 2012

139

*Note: grey cells contain preliminary data2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FCQG71F *FCQG100F *FCQG125F *FCQG140F *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.21 3.30 3.21 3.01 3.21 3.30 3.21 3.01

COP 3.61 3.54 3.41 3.61 3.54 3.41

SEER* 5.11 To be confirmed

5.11 To be confirmedSCOP 3.81 3.80 3.81 3.81 3.80 3.81

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A A/B B/B A/A A/B B/B

Casing Colour To be confirmed To be confirmed

Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840

Weight Unit kg To be confirmed To be confirmed

Decoration panel Model BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14 BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14

Colour Pure White (RAL 9010) Pure White (RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5 5.5 / 5.5 / 11.5

Fan - Air flow rate Cooling High/Nom./Low m³/minTo be confirmed

27.5/-/19.0To be confirmed

27.5/-/19.0

Heating High/Nom./Low m³/min 27.5/-/19.0 27.5/-/19.0

Sound power level Cooling High/Nom./Low dBA To be confirmed To be confirmed

Sound pressure level

Cooling High/Nom./Low dBA 33/31/28 37/35/32 41/38/35 33/31/28 37/35/32 41/38/35

Heating High/Nom./Low dBA 33/31/28 37/35/32 41/38/35 33/31/28 37/35/32 41/38/35

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mmTo be confirmed To be confirmed

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQSG71L7V1B *RZQSG100L7V1B *RZQSG125L7Y1B *RZQSG140L7V1B *RZQSG71L7Y1B *RZQSG100L7Y1B *RZQSG125L7V1B *RZQSG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 770x900x320 990x940x320 990x940x320 1,430x940x320

Weight Unit kg 68 77 99 68 77 99

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400

139139

FCQG-F / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 139 30/11/2011 12:31:17

Page 142: DAIKIN General Catalogue 2012

140

Round flow cassette

› The round flow cassette provides a more comfortable environment and offers greater savings in energy consumption to shop, office and restaurant owners.

› The unique 360° air discharge ensures uniform air flow and temperature distribution

› The infrared presence sensor (optional) adjusts the set point with 2°C if no one is detected in the room. It also automatically directs air flow away from any person to avoid draught.

› The infrared floor sensor (optional) detects the average floor temperature and ensures even temperature distribution between ceiling and floor. Cold feet will become history.

› Individual flap control: one or more flaps can be easily closed via the wired remote controller (BRC1E52A) when refurbishing or rearranging your interior

› Modern style decoration panel is available in 3 different variations: standard panel in white (RAL9010) with grey louvers and standard panel in full white (RAL9010) including white louvers, auto cleaning panel in white (RAL9010) with grey louvers

› For auto cleaning panel (BYCQ140DG) » Daikin introduces first auto cleaning cassette to European market » Higher efficiency and comfort from daily auto cleaning of the filter » Lower maintenance costs thanks to auto cleaning function » Easy removal of dust with a vacuum cleaner without opening the unit

› No optional adapter needed for DIII-connection

Heating & CoolingIndoor units *FCQG60F

Cooling capacity Min./Nom./Max. kW

To be confirmed

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYCQ140DW12 / BYCQ140DW1W3 / BYCQ140DGW14

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-air flow rate Cooling Nom. m³/minTo be confirmed

Heating Nom. m³/min

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Medium/Low dBA

Heating High/Medium/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

To be confirmedGas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mmTo be confirmed

Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes

Total piping length System Actual m To be confirmed

Power supply Phase / Frequency / Voltage Hz / V

*Note: grey cells contain preliminary data2 Pure white standard panel with grey louvers / 3 Pure white standard panel with white louvers / 4 Pure white auto cleaning panel

140

*FCQG35F *FCQG50F

204x840x840

19

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

49 51

31/29/27 33/31/28

31/29/27 33/31/28

1~ / 50/60 / 220-240/220

RXS35J RXS50J RXS60F

550x765x285 735x825x300

34 48

36.0/30.1 50.9/48.9 50.9/45.0

28.3/25.6 45.0/43.1 46.3/46.3

-/63

48/44 49/46

48/45 49/46

-10~46

-15~18

6.35

9.52 12.7

15 20

1~ / 50 / 220-240

140

FCQG-F / RXS-J/F

RXS35J BRC1E52 BRC7F532FFCQG35,50,60F

GC_pre2_lowres.pdf 140 30/11/2011 12:31:18

Page 143: DAIKIN General Catalogue 2012

141

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B B/C D/D

Casing Colour

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYFQ60BAW1

Colour White

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Name / Phase / Frequency / Voltage Hz / V V1 / 1~ / 50 / 230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: up to class A energy labels › Compact casing (575mm in width and depth) enables

unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

› Whisper quiet operation: down to 24.5dBA sound pressure level › Fresh air intake for healthy living › Comfortable vertical auto swing ensures draughtfree

operation and prevents ceiling soiling › Since the flaps can move to a 0 degree position,

virtually no draught can be experienced › Possibility to shut 1 or 2 flaps for easy installation in corners › Easy maintenance: switch box can be reached

by simply removing the suction grille › Standard drain pump with 750mm lift › No optional adapter needed for DIII-connection

4-way blow ceiling mounted cassette

*Note: grey cells contain preliminary data

141

*FFQ25B9V *FFQ35B9V *FFQ50B9V *FFQ60B9V

-/2.5/- -/3.4/- 0.9/4.7/5.6 -/5.80/-

-/3.2/- -/4.0/- 0.9/5.5/7.0 -/7.00/-

-/0.73/- -/1.10/- 0.45/1.80/2.26 -/2.07/-

-/0.920/- -/1.20/- 0.45/1.96/2.78 -/2.49/-

3.42 3.09 2.61 2.80

3.48 3.33 2.81

365 550 900 1,035

-

286x575x575

17.5

55x700x700

2.7

9.0/6.5 10.0/6.5 12.0/8.0 15.0/10.0

9.0/6.5 10.0/6.5 12.0/8.0 15.0/10.0

46.5 49.0 53.0 58.0

29.5/24.5 32.0/25.0 36.0/27.0 41.0/32.0

29.5/24.5 32.0/25.0 36.0/27.0 41.0/32.0

6.35

9.52 12.7

26

RXS25K RXS35J RXS50J RXS60F

550x765x285 550x765x285 735x825x300

34 34 48

33.5/- 36.0/30.1 50.9/48.9 50.9/45.0

28.3/- 28.3/25.6 45.0/43.1 46.3/46.3

-/61 -/63

46/43 48/44 49/46

47/44 48/45 49/46

-10~46 -10~46

-15~18 -15~18

R-410A

- 6.35 -

- 9.52 12.7 -

15 15 20

- -

1~ / 50 / 220-240 1~ / 50 / 220-240

141

FFQ-B9V / RXS-K/J/F

FFQ25,35,50,60B9V RXS60F BRC1E52A BRC7E530W

GC_pre2_lowres.pdf 141 30/11/2011 12:31:18

Page 144: DAIKIN General Catalogue 2012

142

Concealed ceiling unit with inverter driven fan

› Seasonal effi ciency, optimised for all seasons › Seasonal effi ciency gives an indication on how effi cient an air conditioner operates over an entire heating or cooling season › The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable

environment and off ers great savings in energy consumption to shop, restaurant and offi ce owners › Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible › Reduction in power consumption thanks to DC inverter fans › Improved comfort thanks to 3-step air fl ow control › Possibility to change ESP via wired remote control allows optimisation of the supply air volume › Up to 120Pa external static pressure facilitates using fl exible ducts of variying lengths: ideal for shops and medium size offi ces › Whisper quiet operation: down to 29dBA sound pressure level › During start up, the room can be cooled down or heated very quickly; once the temperature in the

room has reached its set point, the low power operation starts to save energy. › Standard air fi lter removes airborne dust particles to ensure a steady supply of clean air › Easy installation thanks to automatic air fl ow adjustment towards nominal air fl ow rate › Standard built-in drain pump increases reliability of the drain system › No optional adapter needed for DIII-connection

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

Preliminary

Heating & CoolingIndoor unit *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8 *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.28 3.31 3.21 3.02 3.28 3.31 3.21 3.02

COP 3.61 3.65 3.51 3.41 3.61 3.65 3.51 3.41

SEER* 5.11 4.35 To be confi rmed

5.11 4.35 To be confi rmedSCOP 3.81 3.81 3.81 3.81 3.81 3.81

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/B B/B A/A A/B B/B

Casing Colour To be confi rmed To be confi rmed

Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700 300x1,000x700 300x1,400x700

Weight Unit kg 34 45 34 45

Decoration panel Model BYBS71DJW1 BYBS125DJW1 BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0,5) White (10Y9/0,5)

Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500 55x1,100x500 55x1,500x500

Weight kg 4.5 6.5 4.5 6.5

Fan - Air fl ow rate Cooling High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28 18/-/15 32/-/23 39/-/28

Heating High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28 18/-/15 32/-/23 39/-/28

Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50 100/30 120/40 120/50

Sound power level Cooling High/Nom./Low dBA -/57/- -/61/- -/66/- -/57/- -/61/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34 37/-/29 38/-/32 40/-/33 41/-/34

Heating High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34 37/-/29 38/-/32 40/-/33 41/-/34

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQSG71L7V1B *RZQSG100L7V1B *RZQSG125L7V1B *RZQSG140L7V1B *RZQSG71L7Y1B *RZQSG100L7Y1B *RZQSG125L7Y1B *RZQSG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 770x900x320 990x940x320 1,430x940x320

Weight Unit kg 68 77 99 68 77 99

Sound power level Cooling Nom. dBA - -

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

142142

FBQ-C8 / RZQG-LV1/Y1

Seasonal Smart

FBQ100,125,140C8 BRC1E52ARZQG100,125,140LV1/Y1

GC_pre2_lowres.pdf 142 30/11/2011 12:31:18

Page 145: DAIKIN General Catalogue 2012

143

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8 *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.50 3.89 3.81 3.33 3.50 3.89 3.81 3.33

COP 3.65 4.21 3.83 3.61 3.65 4.21 3.83 3.61

SEER* 5.61 5.61 To be confirmed

5.61 5.61 To be confirmedSCOP 4.01 4.25 4.05 4.01 4.25 4.05

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A A/A

Casing Colour To be confirmed To be confirmed

Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700 300x1,000x700 300x1,400x700

Weight Unit kg 34 45 34 45

Decoration panel Model BYBS71DJW1 BYBS125DJW1 BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0,5) White (10Y9/0,5)

Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500 55x1,100x500 55x1,500x500

Weight kg 4.5 6.5 4.5 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28 18/-/15 32/-/23 39/-/28

Heating High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28 18/-/15 32/-/23 39/-/28

Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50 100/30 120/40 120/50

Sound power level Cooling High/Nom./Low dBA -/57/- -/61/- -/66/- -/57/- -/61/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34 37/-/29 38/-/32 40/-/33 41/-/34

Heating High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34 37/-/29 38/-/32 40/-/33 41/-/34

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQG71L7V1B *RZQG100L7V1B *RZQG125L7V1B *RZQG140L7V1B *RZQG71L7Y1B *RZQG100L7Y1B *RZQG125L7Y1B *RZQG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 68 64 66 67 68

Sound pressure level

Cooling Nom. dBA 48 50 51 51 48 50 51 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

143143

FBQ-C8 / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 143 30/11/2011 12:31:18

Page 146: DAIKIN General Catalogue 2012

144

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating C/C B/B A/B

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS45DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Fan - External static pressure High/Nom. Pa

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: up to class A energy labels › Reduction in power consumption thanks to DC inverter fans › Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible › Improved comfort thanks to 3-step air flow control › Up to 100Pa external static pressure facilitates using flexible ducts

of variying lengths: ideal for shops and medium size offices › Possibility to change ESP via wired remote control

allows optimisation of the supply air volume › Whisper quiet operation: down to 29dBA sound pressure level › Easy installation thanks to automatic air flow

adjustment towards nominal air flow rate › Standard air filter removes airborne dust particles

to ensure a steady supply of clean air › Standard built-in drain pump increases reliability of the drain system › No optional adapter needed for DIII-connection

Concealed ceiling unit with inverter driven fan

144

FBQ35C8 FBQ50C8 FBQ60C8

-/3.40/- 0.9/5.0/5.6 -/5.70/-

-/4.00/- 0.9/6.0/7.0 -/7.00/-

-/1.17/- 4.50/1.83/2.02 1.75

-/1.22/- 0.36/2.05/2.45 2.05

2.91 2.73 3.26

3.28 2.93 3.41

585 825 875

300x700x700 300x1,000x700

350

25 34

55x800x500 55x1,100x500

3.5 4.5

16/11 18/15

16/11 18/15

100/30

63 57

37/29

37/29

6.35

9.52 12.7

VP 25 (OD 32/ID 25) 26 32

RXS35J RXS50J RXS60F

550x765x285 735x825x300

34 48

36.0/30.1 50.9/48.9 50.9/45.0

28.3/25.6 45.0/43.1 46.3/46.3

-/63

48/44 49/46

48/45 49/46

-10~46

-15~18

6.35 -

9.52 12.7 -

15 20

-

1~ / 50 / 220-240

144

FBQ-C8 / RXS-J/F

FBQ35,50C8 RXS35J BRC1E52A

GC_pre2_lowres.pdf 144 30/11/2011 12:31:18

Page 147: DAIKIN General Catalogue 2012

145

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER

COP

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Fan - External static pressure High/Nom./Low Pa

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High dBA

Heating Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Fan - External static pressure Max. Pa

Sound power level Cooling Nom. dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

Concealed ceiling unit

› Up to 250 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas

› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

› Up to 26.4 kW in heating mode › Home leave operation saves energy during absence › Standard air filter: removes airborne dust particles

to ensure a steady supply of clean air

145

FDQ200B FDQ250B

-/20.0/- -/24.1/-

-/23.0/- -/26.4/-

-/6.23/- -/8.58/-

-/6.74/- -/8.22/-

3.21 2.81

3.41 3.21

450x1,400x900

450

89.0 94.0

69.0 89.0

69.0 89.0

250/250/250

81.0 82.0

45.0 47.0

45.0 47.0

9.52 12.7

22.2

25

RZQ200C RZQ250C

1,680x930x765

183 184

171

171

78

78

-5.0~46.0

-15.0~15.0

-

100

3N~ / 50 / 380-415

145

FDQ-B / RZQ-C

RZQ200,250CFDQ200,250B BRC1E52A

GC_pre2_lowres.pdf 145 30/11/2011 12:31:19

Page 148: DAIKIN General Catalogue 2012

146

Concealed ceiling unit

› Seasonal effi ciency, optimised for all seasons › Seasonal effi ciency gives an indication on how effi cient an air conditioner operates over an entire heating or cooling season › The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable

environment and off ers great savings in energy consumption to shop, restaurant and offi ce owners › Up to 200Pa external static pressure allows extensive ductwork runs and fl exible application: ideal for use in large areas › New casing: reduced height to fi t fl ush into false ceilings › Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible › Standard air fi lter removes airborne dust particles to ensure a steady supply of clean air › During start up, the room can be cooled down or heated very quickly; once the temperature in the

room has reached its set point, the low power operation starts to save energy › Easy installation:

- Less duct calculation- Air fl ow can be adjusted during installation via the wired remote control instead of channel adjustments

› Standard drain pump › No optional adapter needed for DIII-connection

*prEN14825 (inquiry version 2010) *Note: grey cells contain preliminary data

Preliminary

Heating & CoolingIndoor unit *FDQ125C *FDQ125C

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.75 3.75

COP 3.83 3.83

SEER* 5.61 5.61

SCOP 4.05 4.05

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/A

Casing Colour Not painted (galvanised) Not painted (galvanised)

Dimensions Unit HeightxWidthxDepth mm 300x1,400x700 300x1,400x700

Required ceiling void > mm 350 350

Weight Unit kg 45 45

Decoration panel Model BYBS125DJW1 BYBS125DJW1

Colour White (10Y9/0.5) White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm 55x1,500x500 55x1,500x500

Weight kg 6.5 6.5

Fan - Air fl ow rate Cooling High/Nom./Low m³/min 39/-/28 39/-/28

Heating High/Nom./Low m³/min 39/-/28 39/-/28

Fan - External static pressure High/Nom. Pa 200/50 200/50

Sound power level Cooling High/Nom./Low dBA -/66/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 40/-/33 40/-/33

Heating High/Nom./Low dBA 40/-/33 40/-/33

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQG125L7V1 *RZQG125LY1

Dimensions Unit HeightxWidthxDepth mm 1,430x940x320 1,430x940x320

Weight Unit kg 99 99

Sound power level Cooling Nom. dBA 67 67

Sound pressure level

Cooling Nom. dBA 51 51

Heating Nom. dBA 53 53

Night quiet mode Level 1 dBA 45 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

146146

FDQ-C / RZQG-LV1/Y1

Seasonal Smart

RZQG125LV1/Y1 BRC1E52AFDQ125C

GC_pre2_lowres.pdf 146 30/11/2011 12:31:19

Page 149: DAIKIN General Catalogue 2012

147

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FDQ125C *FDQ125C

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.21 3.21

COP 3.51 3.51

SEER* 4.31 4.31

SCOP 3.81 3.81

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/B A/B

Casing Colour Not painted (galvanised) Not painted (galvanised)

Dimensions Unit HeightxWidthxDepth mm 300x1,400x700 300x1,400x700

Required ceiling void > mm 350 350

Weight Unit kg 45 45

Decoration panel Model BYBS125DJW1 BYBS125DJW1

Colour White (10Y9/0.5) White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm 55x1,500x500 55x1,500x500

Weight kg 6.5 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 39/-/28 39/-/28

Heating High/Nom./Low m³/min 39/-/28 39/-/28

Fan - External static pressure High/Nom. Pa 200/50 200/50

Sound power level Cooling High/Nom./Low dBA -/66/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 40/-/33 40/-/33

Heating High/Nom./Low dBA 40/-/33 40/-/33

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

Outdoor unit *RZQSG125LV1 *RZQSG125LY1

Dimensions Unit HeightxWidthxDepth mm 990x940x320 990x940x320

Weight Unit kg 77 77

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

147147

FDQ-C / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 147 30/11/2011 12:31:19

Page 150: DAIKIN General Catalogue 2012

148

Wall mounted unit

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

› Seasonal effi ciency, optimized for all seasons › Seasonal effi ciency gives an indication on how effi cient air conditioners operate over an entire heating or cooling season. › Can be installed in both new and existing buildings › Ideal solution for shops, restaurants or offi ces without false ceilings › Extension of the range: a 125 class has been developed for installation in larger rooms › Modern style fl at front panel › Front panel can easily be removed and cleaned › No optional adapter needed for DIII-connection › Automatic fan speed selection: 3 fan speeds can be selected

Preliminary

NEW

Heating & CoolingIndoor unit *FAQ71C *FAQ100C *FAQ125C *FAQ71C *FAQ100C *FAQ125C

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmed To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.40 3.62 - 3.40 3.62 -

COP 3.70 3.61 - 3.70 3.61 -

SEER* 5.21 5.11 - 5.21 5.11 -

SCOP 3.90 4.01 - 3.90 4.01 -

Annual energy consumption kWh To be confi rmed To be confi rmed To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A -/- A/A -/-

Casing Colour Fresh white (6.5Y 9.5/0.5) To be confi rmed Fresh white (6.5Y 9.5/0.5) To be confi rmed

Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240 290x1,050x238 340x1,200x240 340x1,200x240

Weight Unit kg 13 17 17 13 17 17

Fan - Air fl ow rate Cooling High/Nom./Low m³/min 18/16/14 26/23/19

To be confi rmed

18/16/14 26/23/19

To be confi rmed

Heating High/Nom./Low m³/min 18/16/14 26/23/19 18/16/14 26/23/19

Sound power level Cooling High/Nom./Low dBA 61/58/56 65/62/58 61/58/56 65/62/58

Heating High/Nom./Low dBA 61/58/56 65/62/58 61/58/56 65/62/58

Sound pressure level

Cooling High/Nom./Low dBA 45/42/40 49/45/41 45/42/40 49/45/41

Heating High/Nom./Low dBA 45/42/40 49/45/41 45/42/40 49/45/41

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 / 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 / 1~ / 50/60 / 220-240/220

Outdoor unit *RZQG71L7V1 *RZQG100L7V1 *RZQG125L7V1 *RZQG71LY1 *RZQG100LY1 *RZQG125LY1

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 64 66 67

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

148148

FAQ-C / RZQG-LV1/Y1

Seasonal Smart

RZQG100,125LV1/Y1FAQ100,125C BRC1E52A BRC7E618

GC_pre2_lowres.pdf 148 30/11/2011 12:31:19

Page 151: DAIKIN General Catalogue 2012

149

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

NEW NEW

Heating & CoolingIndoor unit *FAQ71C *FAQ100C *FAQ125C *FAQ71C *FAQ100C *FAQ125C

Cooling capacity Min./Nom./Max. kW

To be confirmed

To be confirmed

To be confirmed

To be confirmed

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.21 3.01 3.21 3.01

COP 3.61 3.41 3.61 3.41

SEER* 5.11 4.61 5.11 4.61

SCOP 3.81 3.81

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A B/B A/A B/B

Casing Colour Fresh white (6.5Y 9.5/0.5) Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240 290x1,050x238 340x1,200x240 340x1,200x240

Weight Unit kg 13 17 17 13 17 17

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/16/14 26/23/19

To be confirmed

18/16/14 26/23/19

To be confirmed

Heating High/Nom./Low m³/min 18/16/14 26/23/19 18/16/14 26/23/19

Sound power level Cooling High/Nom./Low dBA 61/58/56 65/62/58 61/58/56 65/62/58

Heating High/Nom./Low dBA 61/58/56 65/62/58 61/58/56 65/62/58

Sound pressure level

Cooling High/Nom./Low dBA 45/42/40 49/45/41 45/42/40 49/45/41

Heating High/Nom./Low dBA 45/42/40 49/45/41 45/42/40 49/45/41

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220

Outdoor unit *RZQSG71LV1 *RZQSG100LV1 *RZQSG125LV1 *RZQSG71LY1 *RZQSG100LY1 *RZQSG125LY1

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 770x900x320 990x940x320

Weight Unit kg 68 77 68 77

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

149149

FAQ-C / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 149 30/11/2011 12:31:19

Page 152: DAIKIN General Catalogue 2012

150

Concealed ceiling unit

*prEN14825 (inquiry version 2010) *Note: grey cells contain preliminary data

› Seasonal effi ciency, optimised for all seasons › Seasonal effi ciency gives an indication on how effi cient an air conditioner operates over an entire heating or cooling season › Energy effi cient units: up to class A energy labels › Can be installed in both new and existing buildings › Ideal solution for shops, restaurants or offi ces without false ceilings › The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space › The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable

environment and off ers great savings in energy consumption to shop, restaurant and offi ce owners › During start up, the room can be cooled down or heated very quickly; once the temperature in the

room has reached its set point, the low power operation starts to save energy. › No optional adapter needed for DIII-connection › Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall

Preliminary

Heating & CoolingIndoor unit *FHQG71C *FHQG100C *FHQG125C *FHQG140C *FHQG71C *FHQG100C *FHQG125C *FHQG140C

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.82 3.81 3.35 3.31 3.82 3.81 3.35 3.31

COP 4.13 4.15 3.89 3.63 4.13 4.15 3.89 3.63

SEER* 5.65 5.69 5.11 - 5.65 5.69 5.11 -

SCOP 3.95 4.20 4.01 - 3.95 4.20 4.01 -

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/A

Casing Colour Fresh white (6.5Y 9.5/0.5) Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690

Weight Unit kg 32 38 32 38

Fan - Air fl ow rate Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 20.5/17/14 28/24/20 31/27/23 34/29/24

Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 20.5/17/14 28/24/20 31/27/23 34/29/24

Sound power level Cooling High/Nom./Low dBA -/55/- -/60/- -/62/- -/64/- -/55/- -/60/- -/62/- -/64/-

Sound pressure level

Cooling High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38 38/36/34 42/38/34 44/41/37 46/42/38

Heating High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38 38/36/34 42/38/34 44/41/37 46/42/38

Refrigerant Type

To be confi rmed To be confi rmedPiping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit *RZQG71L7V1B *RZQG100L7V1B *RZQG125L7V1B *RZQG140L7V1B *RZQG71L7Y1B *RZQG100L7Y1B *RZQG125L7Y1B *RZQG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 68 64 66 67 68

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

150150

FHQG-C / RZQG-LV1/Y1

Seasonal Smart

FHQG71C BRC1E52ARZQG100,125,140LV1/Y1

GC_pre2_lowres.pdf 150 30/11/2011 12:31:20

Page 153: DAIKIN General Catalogue 2012

151

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FHQG71C *FHQG100C *FHQG125C *FHQG140C *FHQG71C *FHQG100C *FHQG125C *FHQG140C

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.46 3.21 2.89 3.01 3.46 3.21 2.89 3.01

COP 4.00 3.61 3.62 3.41 4.00 3.61 3.62 3.41

SEER* 5.11 4.61 - 5.11 4.61 -

SCOP 3.81 3.80 3.81 - 3.81 3.80 3.81 -

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A C/A B/B A/A C/A B/B

Casing Colour Fresh white (6.5Y 9.5/0.5) Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690

Weight Unit kg 32 38 32 38

Fan - Air flow rate Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 20.5/17/14 28/24/20 31/27/23 34/29/24

Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 20.5/17/14 28/24/20 31/27/23 34/29/24

Sound power level Cooling High/Nom./Low dBA -/55/- -/60/- -/62/- -/64/- -/55/- -/60/- -/62/- -/64/-

Sound pressure level

Cooling High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38 38/36/34 42/38/34 44/41/37 46/42/38

Heating High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38 38/36/34 42/38/34 44/41/37 46/42/38

Refrigerant Type

To be confirmed To be confirmedPiping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit *RZQSG71L7V1B *RZQSG100L7V1B *RZQSG125L7V1B *RZQSG140L7V1B *RZQSG71L7Y1B *RZQSG100L7Y1B *RZQSG125L7Y1B *RZQSG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 770x900x320 990x940x320 1,430x940x320

Weight Unit kg 68 77 99 68 77 99

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

151151

FHQG-C / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 151 30/11/2011 12:31:20

Page 154: DAIKIN General Catalogue 2012

152

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Min./Nom./Max. kW

Heating Min./Nom./Max. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating A/B D/D

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Low dBA

Heating High/Low dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Super low m³/min

Heating High/Super low m³/min

Sound power level Cooling Nom./High dBA

Sound pressure level

Cooling High/Silent operation dBA

Heating High/Silent operation dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Level difference IU - OU Max. m

Heat insulation Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

› Energy efficient units: up to class A energy labels › Can be installed in both new and existing buildings › Wider air discharge thanks to Coanda effect: up to 100°

100°

› Air flow distribution for ceiling heights up to 3.8m without capacity loss › The unit can easily be mounted in corners and narrow

spaces, as it only needs 30mm lateral service space › Daikin outdoor units are neat, sturdy and can easily be mounted

on a roof or terrace or simply placed against an outside wall › Outdoor unit silent operation: “silent” button on the remote

control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood.

Ceiling suspended unit

152

FHQ35B FHQ50B FHQ60B

1.4/3.4/3.7 1.7/5.0/5.6 1.7/5.7/6.0

1.2/4.0/5.0 1.7/6.0/7.0 1.7/7.2/8.0

-/1.050/- 0.440/1.830/2.020 0.44/2.15/2.23

-/1.110/- 0.400/2.050/2.450 0.40/2.49/2.75

3.24 2.73 2.65

3.60 2.93 2.89

525 915 1,075

195x960x680 195x1,160x680

24 25 27

13/10 17/13

13/10 16/13

53/48 54/49 55/49

53/48 54/49 55/49

37/32 38/33 39/33

37/32 38/33 39/33

6.35

9.5 12.7

RXS35J RXS50J RXS60F

550x765x285 735x825x300

34 48

36.0/30.1 50.9/48.9 50.9/45.0

28.3/25.6 45.0/43.1 46.3/46.3

-/63

48/44 49/46

48/45 49/46

-10~46

-15~18

6.35

9.52 12.7

15 20

-

1~ / 50 / 220-240

152

FHQ-B / RXS-J/F

FHQ35,50B RXS35J BRC1E52A BRC7EA63W

GC_pre2_lowres.pdf 152 30/11/2011 12:31:20

Page 155: DAIKIN General Catalogue 2012

153

Concealed ceiling unit

*prEN14825 (inquiry version 2010) *Note: grey cells contain preliminary data

› Seasonal effi ciency, optimised for all seasons › Seasonal effi ciency gives an indication on how effi cient an

air conditioner operates over an entire heating or cooling season Energy effi cient units: up to class A energy labels

› The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable environment and off ers great savings in energy consumption to shop, restaurant and offi ce owners

› Can be installed in both new and existing buildings › Air can be discharged in any of 4 directions › Auto swing function ensures effi cient air and temperature distribution › Air can be discharged in 5 diff erent angles between 0 and 60° › Possibility to shut 1 or 2 fl aps for easy installation in corners › Air fl ow distribution for ceiling heights up to 3.5m without capacity loss › Vertical auto swing moves the discharge fl aps up and down for

effi cient air and temperature distribution throughout the room › An inverter driven compressor allows the capacity to be adjusted

precisely to match variations in room and outside temperatures › During start up, the room can be cooled down or heated very

quickly; once the temperature in the room has reached its set point, the low power operation starts to save energy.

› Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall

Preliminary

Heating & CoolingIndoor unit *FUQ71B *FUQ100B *FUQ125B *FUQ71B *FUQ100B *FUQ125B

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 4.05 3.86 3.39 4.05 3.86 3.39

COP 4.08 3.95 3.42 4.08 3.95 3.42

SEER* 5.25 4.67 4.41 5.25 4.67 4.41

SCOP 3.89 4.02 4.09 3.89 4.02 4.09

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/B A/A A/B

Casing Colour White White

Dimensions Unit HeightxWidthxDepth mm 165x895x895 230x895x895 165x895x895 230x895x895

Weight Unit kg 25.0 31.0 25.0 31.0

Fan - Air fl ow rate Cooling High/Nom./Low m³/min 19.0/-/14.0 29.0/-/21.0 32.0/-/23.0 19.0/-/14.0 29.0/-/21.0 32.0/-/23.0

Heating High/Nom./Low m³/min 19.0/-/14.0 29.0/-/21.0 32.0/-/23.0 19.0/-/14.0 29.0/-/21.0 32.0/-/23.0

Sound power level Cooling High/Nom./Low dBA 56/-/51.0 59.0/-/54.0 60/-/55 56/-/51.0 59.0/-/54.0 60/-/55

Heating High/Low dBA 56/51 59.0/54.0 60/55 56/51 59.0/54.0 60/55

Sound pressure

level

Cooling High/Nom./Low dBA 40/-/35 43.0/-/38.0 44/-/39 40/-/35 43.0/-/38.0 44/-/39

Heating High/Nom./Low dBA 40/-/35 43.0/-/38.0 44/-/39 40/-/35 43.0/-/38.0 44/-/39

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mmTo be confi rmed To be confi rmed

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit *RZQG71L7V1 *RZQG100L7V1 *RZQG125L7V1 *RZQG71LY1 *RZQG100LY1 *RZQG125LY1

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 64 66 67

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

153153

FUQ-B / RZQG-LV1/Y1

Seasonal Smart

FUQ71B BRC1E52A BRC7CA528WRZQG100,125LV1/Y1

GC_pre2_lowres.pdf 153 30/11/2011 12:31:20

Page 156: DAIKIN General Catalogue 2012

154

Floor standing unit

*prEN14825 (inquiry version 2010) *Note: grey cells contain preliminary data

› Seasonal effi ciency, optimised for all seasons › Seasonal effi ciency gives an indication on how effi cient an air conditioner operates over an entire heating or cooling › The Sky Air inverter is developed for use in light commercial applications, provides a more comfortable

environment and off ers great savings in energy consumption to shop, restaurant and offi ce owners › Can be installed in both new and existing buildings › During start up, the room can be cooled down or heated very quickly; once the temperature in the

room has reached its set point, the low power operation starts to save energy. › Beter airfl ow distribution › Decrease in temperature variation with the air volume UP function (via remote control) › No optional adapter needed for DIII-connection › Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall

Preliminary

Heating & CoolingIndoor unit *FVQ71C *FVQ100C *FVQ125C *FVQ140C *FVQ71C *FVQ100C *FVQ125C *FVQ140C

Cooling capacity Min./Nom./Max. kW

To be confi rmed To be confi rmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.37 3.81 3.21 3.37 3.81 3.21

COP 3.64 4.14 3.70 3.61 3.64 4.14 3.70 3.61

SEER* 5.16 5.59 4.77 To be confi rmed

5.16 5.59 4.77 To be confi rmedSCOP 3.81 3.80 3.85 3.81 3.80 3.85

Annual energy consumption kWh To be confi rmed To be confi rmed

Energy label Cooling/Heating A/A A/A

Casing Colour Fresh white Fresh white

Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350

Weight Unit kg 39 47 47 47 39 47 47 47

Fan - Air fl ow rate Cooling High/Nom./Low m³/minTo be confi rmed To be confi rmed

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA 55/53/50 62/59/56 63/60/58 65/63/60 55/53/50 62/59/56 63/60/58 65/63/60

Sound pressure level

Cooling High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48

Heating High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Name / Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit *RZQG71L7V1B *RZQG100L7V1B *RZQG125L7V1B *RZQG140L7V1B *RZQG71L7Y1B *RZQG100L7Y1B *RZQG125L7Y1B *RZQG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Sound power level Cooling Nom. dBA 64 66 67 68 64 66 67 68

Sound pressure level

Cooling Nom. dBA 48 50 51 48 50 51

Heating Nom. dBA 50 52 53 50 52 53

Night quiet mode Level 1 dBA 43 45 43 45

Operation range Cooling Ambient Min.~Max. °CDB -15~50 -15~50

Heating Ambient Min.~Max. °CWB -20~15.5 -20~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level diff erence IU - OU Max. mTo be confi rmed To be confi rmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

154154

FVQ-C / RZQG-LV1/Y1

Seasonal Smart

FVQ-C BRC1E52A RZQG100,125,140LV1/Y1

GC_pre2_lowres.pdf 154 30/11/2011 12:31:20

Page 157: DAIKIN General Catalogue 2012

155

*Note: grey cells contain preliminary data*prEN14825 (inquiry version 2010)

Heating & CoolingIndoor unit *FVQ71C *FVQ100C *FVQ125C *FVQ140C *FVQ71C *FVQ100C *FVQ125C *FVQ140C

Cooling capacity Min./Nom./Max. kW

To be confirmed To be confirmedHeating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

EER 3.21 2.81 3.01 3.21 2.81 3.01

COP 3.61 3.41 3.41 3.61 3.41 3.41

SEER* 5.11 4.31 To be confirmed

5.11 4.31 To be confirmedSCOP 3.81 3.80 3.81 3.81 3.80 3.81

Annual energy consumption kWh To be confirmed To be confirmed

Energy label Cooling/Heating A/A C/B B/B A/A C/B B/B

Casing Colour Fresh white Fresh white

Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x270

Weight Unit kg 39 47 39 47

Fan - Air flow rate Cooling High/Nom./Low m³/minTo be confirmed To be confirmed

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA 55/53/50 62/59/56 63/60/58 65/63/60 55/53/50 62/59/56 63/60/58 65/63/60

Sound pressure level

Cooling High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48

Heating High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48 43/41/38 50/47/44 51/48/46 53/51/48

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm 9.52 9.52

Gas OD mm 15.9 15.9

Power supply Name / Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

Outdoor unit *RZQSG71L7V1B *RZQSG100L7V1B *RZQSG125L7V1B *RZQSG140L7V1B *RZQSG71L7Y1B *RZQSG100L7Y1B *RZQSG125L7Y1B *RZQSG140L7Y1B

Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320 1,430x940x320 770x900x320 990x940x320 1,430x940x320

Weight Unit kg 68 77 99 68 77 99

Sound power level Cooling Nom. dBA To be confirmed To be confirmed

Operation range Cooling Ambient Min.~Max. °CDB -5~46 -5~46

Heating Ambient Min.~Max. °CWB -10~15.5 -10~15.5

Refrigerant Type R-410A R-410A

Piping connections

Level difference IU - OU Max. mTo be confirmed To be confirmed

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400

155155

FVQ-C / RZQSG-LV1/Y1

GC_pre2_lowres.pdf 155 30/11/2011 12:31:21

Page 158: DAIKIN General Catalogue 2012

156

› Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings

› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

› Air can be discharged in any of 4 directions › Air filter removes airborne dust particles to

ensure a steady supply of clean air › Easy installation and maintenance › Daikin air conditioners are energy efficient and economical › The use of inverter type outdoor units results in an air

conditioning system with a high energy efficiency › Daikin outdoor units are neat, sturdy and can easily be mounted

on a roof or terrace or simply placed against an outside wall › Outdoor units for pair application

4-way blow ceiling mounted cassette

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Dimensions HeightxWidthxDepth mm

Fan - Air flow rate Cooling High/Nom./Low/Silent operation cfm

Heating High/Nom./Low/Silent operation cfm

Sound power level Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low/Silent operation dBA

Heating High/Nom./Low/Silent operation dBA

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230 1~ / 50 / 230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. cfm

Heating Nom. cfm

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Night quiet mode Level 1 dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Level difference IU - OU Max. m

IU - IU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

156

ACQ71A ACQ100A ACQ125A ACQ100A ACQ125A

-/7.4/- -/10.2/- -/13.0/- -/10.50/-

-/8.3/- -/11.9/- -/14.1/- -/11.20/-

2.24 3.18 4.03 3.17

2.30 3.30 3.91 3.10

3.31 3.21 3.23 3.31

3.61 3.61

1,120 1,590 2,015 1,585

A/A

300x820x820 335x820x820 335x820x820

31.0 39.0 41.0 39.0 41.0

40x170x170 40x170x170

860/725/620/530 1,030/860/740/620 1,200/1,030/930/780 1,030/860/740/620 1,200/1,030/930/780

860/725/620/530 1,030/860/740/620 1,200/1,030/930/780 1,030/860/740/620 1,200/1,030/930/780

54/50/48 57/55/54 60/57/55 57/55/54 60/57/55

54/50/48 57/55/54 60/57/55 57/55/54 60/57/55

41/38/35/32 44/41/38/36 47/44/43/39 44/41/38/36 47/44/43/39

41/38/35/32 44/41/38/36 47/44/43/39 44/41/38/36 47/44/43/39

9.52 9.52

15.88 15.88

AZQS71AV1 AZQS100AV1 AZQS125AV1 AZQS100AW1 AZQS125AW1

770x900x320 1,345x900x320 1,345x900x320

67 109 106

52 96 100 103.0

48 90 101.0

64 65 67 65.0 66.0

48 50 51 49.0 50.0

50 52 53 51.0 52.0

43 45 45.0

-15.0~50.0 -15~50

-20.0~15.5 -20~15.5

9.52 9.52

15.9 15.9

26 26

30.0 30.0

0.5 0.5

- -

1~ / 50 / 220-240 3~ / 50 / 400

156

ACQ71A AZQS71AV1/W1 ARCWLA

ACQ-A / AZQS-AV1/AW1

GC_pre2_lowres.pdf 156 30/11/2011 12:31:21

Page 159: DAIKIN General Catalogue 2012

157

› Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings

› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

› Compact dimensions, can easily be mounted in a narrow ceiling void › Air filter removes airborne dust particles to

ensure a steady supply of clean air › Easy installation and maintenance › Daikin air conditioners are energy efficient and economical › The use of inverter type outdoor units results in an air

conditioning system with a high energy efficiency › Daikin outdoor units are neat, sturdy and can easily be mounted

on a roof or terrace or simply placed against an outside wall › Outdoor units for pair application

Concealed ceiling unit

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating A/A B/B

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low cfm

Heating High/Nom./Low cfm

Fan - External static pressure Super high/High/Nom./Low Pa

Sound power level Cooling Super high/High/Nom./Low dBA

Heating High/Nom./Low dBA

Sound pressure level

Cooling Super high/High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230 1~ / 50 / 230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Night quiet mode Level 1 dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Level difference IU - OU Max. m

IU - IU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

157

ABQ71A ABQ100A ABQ125A ABQ140A ABQ100A ABQ125A ABQ140A

-/7.2/- -/10.2/- -/13.3/- -/13.9/- -/10.20/- -/12.50/- -/14.0/-

-/8.3/- -/11.2/- -/15.9/- -/16.5/- -/11.20/- -/13.70/- -/16.5/-

2.21 3.09 4.15 4.61 3.08 4.10 4.76

2.21 3.03 4.40 4.83 3.10 3.80 4.57

3.26 3.30 3.21 3.01 3.31 3.05 2.94

3.75 3.71 3.62 3.41 3.61

1,105 1,545 2,075 2,305 1,540 2,050 2,380

A/A B/A C/A

285x1,020x600 305x1,325x638 378x1,388x541 378x1,588x541 305x1,325x638 378x1,388x541 378x1,588x541

35.0 47.0 50.0 56.0 47.0 50.0 56.0

850/700/590/480 1,280/1,160/1,050/920 1,430/1,320/1,230/1,130 1,720/1,550/1,340/1,170 1,280/1,160/1,050/920 1,430/1,320/1,230/1,130 1,720/1,550/1,340/1,170

850/700/590/480 1,280/1,160/1,050/920 1,430/1,320/1,230/1,130 1,720/1,550/1,340/1,170 1,280/1,160/1,050/920 1,430/1,320/1,230/1,130 1,720/1,550/1,340/1,170

78/53/38/25 118/96/78/61 147/126/109/92 147/120/90/69 118/96/78/61 147/126/109/92 147/120/90/69

67/64/61/57 80/76/73/70 78/76/73/70 79/78/75/71 80/76/73/70 78/76/73/70 79/78/75/71

64/61/57 76/73/70 78/75/71 76/73/70 78/75/71

44/41/38/34 55/51/48/45 53/52/50/47 55/53/50/47 55/51/48/45 53/52/50/47 55/53/50/47

41/38/34 51/48/45 52/50/47 53/50/47 51/48/45 52/50/47 53/50/47

9.52 9.52

15.88 15.88

AZQS71AV1 AZQS100AV1 AZQS125AV1 AZQS140AV1 AZQS100AW1 AZQS125AW1 AZQS140AW1

770x900x320 1,345x900x320 1,345x900x320

67 109 106

52 96 100 97 103.0 99.0

48 90 101.0 100.0

64 65 67 68 65.0 66.0

48 50 51 49.0 50.0

50 52 53 51.0 52.0

43 45 46 45.0

-15.0~50.0 -15~50

-20.0~15.5 -20~15.5

9.52 9.52

15.9 15.9

26 26

30.0 30.0

0.5 0.5

- -

1~ / 50 / 220-240 3~ / 50 / 400

157

ABQ71A AZQS71AW1 ARCWA

ABQ-A / AZQS-AV1/AW1

GC_pre2_lowres.pdf 157 30/11/2011 12:31:21

Page 160: DAIKIN General Catalogue 2012

158

› Ideal solution for shops, restaurants or offices without false ceilings › Can be installed in both new and existing buildings › Air filter removes airborne dust particles to

ensure a steady supply of clean air › Easy installation and maintenance › Outdoor units are fitted with a scroll compressor, renowned

for its low noise and high energy efficiency › Outdoor units are fitted with a swing compressor, renowned

for its low noise and high energy efficiency › Daikin air conditioners are energy efficient and economical › The use of inverter type outdoor units results in an air

conditioning system with a high energy efficiency › Daikin outdoor units are neat, sturdy and can easily be mounted

on a roof or terrace or simply placed against an outside wall › Outdoor units for pair application

Ceiling suspended unit

Heating & CoolingIndoor unit

Cooling capacity Min./Nom./Max. kW

Heating capacity Min./Nom./Max. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Annual energy consumption kWh

Energy label Cooling/Heating B/D B/C C/C D/A

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. cfm

Heating Nom. cfm

Sound power level Cooling High dBA

Heating High dBA

Sound pressure level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230 1~ / 50 / 230

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Night quiet mode Level 1 dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Level difference IU - OU Max. m

IU - IU Max. m

Heat insulation Both liquid and gas pipes Both liquid and gas pipes

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

158

AHQ71A AHQ100A AHQ125A AHQ140A AHQ100A AHQ125A AHQ140A

-/7.6/- -/9.7/- -/12.6/- -/13.5/- -/10.00/- -/12.50/- -/12.70/-

-/8.1/- -/11.4/- -/15.4/- -/16.6/- -/11.20/- -/14.00/- -/15.10/-

2.51 3.20 4.44 5.13 3.24 4.24 5.02

2.66 3.51 4.80 4.37 3.10 4.00 4.31

3.03 2.84 2.63 3.09 2.95 2.53

3.05 3.25 3.21 3.80 3.61 3.50

1,255 1,600 2,220 2,565 1,620 2,120 2,510

B/A C/B E/B

218x1,090x630 260x1,538x634 260x1,786x634 285x1,902x680 260x1,538x634 260x1,786x634 285x1,902x680

27 45 65 70 45 65 70

640 1,100 1,324 1,550 1,100 1,324 1,550

640 1,100 1,324 1,550 1,100 1,324 1,550

66 68 - 70 68 - 70

66 68 - 70 68 - 70

56/51/44 52/47/46 52/50/49 56/53/46 52/47/46 52/50/49 56/53/46

56/51/44 52/47/46 52/50/49 56/53/46 52/47/46 52/50/49 56/53/46

9.52 9.52

15.88 15.88

AZQS71AV1 AZQS100AV1 AZQS125AV1 AZQS140AV1 AZQS100AW1 AZQS125AW1 AZQS140AW1

770x900x320 1,345x900x320 1,345x900x320

67 109 106

52 96 100 97 103.0 99.0

48 90 101.0 100.0

64 65 67 68 65.0 66.0

48 50 51 49.0 50.0

50 52 53 51.0 52.0

43 45 46 45.0

-15.0~50.0 -15~50

-20.0~15.5 -20~15.5

9.52 9.52

15.9 15.9

26 26

30.0 30.0

0.5 0.5

- -

1~ / 50 / 220-240 3~ / 50 / 400

158

AHQ71A AZQS71AV1 ARCWLA

AHQ-A / AZQS-AV1/AW1

GC_pre2_lowres.pdf 158 30/11/2011 12:31:21

Page 161: DAIKIN General Catalogue 2012

159

GC_pre2_lowres.pdf 159 30/11/2011 12:31:22

Page 162: DAIKIN General Catalogue 2012

160

Commercial multi system

› Especially developed for light commercial applications (shops, restaurants, bars, hairdressers, small offices or 2-storey areas) where multi systems are required

› High efficiency: COP ranges up to 4.1 › Asymmetric combination is allowed: combination of different

indoor units with different capacities is possible › Individual control: up to 4 indoor units can be controlled individually › Maximum piping length up to 200m and level

difference (outdoor unit-indoor unit) up to 30m › Possibility to install the unit on the roof, placed

against an outside wall or even indoors

CONNECTABLE INDOOR UNITS FMDQ50B FMDQ60B FMDQ71B FMDQ100B FMDQ125B

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void mm

Weight Unit kg

Decoration panel Model BYBS45DJW1 BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-External static pressure

High Pa

Nom. Pa

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

Power supply Phase / Frequency / Voltage Hz / V

Heating & CoolingCONNECTABLE INDOOR UNITS FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYCQ140CW11 / BYCQ140CW1W2 / BYCQ140CGW13

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Sound power level Cooling High/Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (I.D. 25/O.D. 32) 9.52/15.9/VP25 (I.D. 25/O.D. 32)

Power supply Phase / Frequency / Voltage Hz / V1 Pure white standard panel with grey louvers / 2 Pure white standard panel with louvers / 3 Pure white auto cleaning panel

160

5.0 6.0 7.1 10.0 12.5

5.6 6.7 8.0 12.5 14.0

0.192 0.142 0.163 0.247 0.303

0.192 0.142 0.163 0.247 0.303

300x700x700 300x1,000x700 300x1,400x700

350

26 35 46

55x800x500 55x1,100x500 55x1,500x500

3.5 4.5 6.5

100 120

30 40 50

63 59 63 61 66

37/29 37/30 38/32 40/33

37/29 37/30 38/32 40/33

1~ / 50/60 / 220-240/220

5.0 6.0 7.1 10.0 12.5

5.6 6.7 8.0 11.2 14.0

0.083 0.095 0.120 0.173 0.258

0.067 0.114 0.108 0.176 0.246

204x840x840 246x840x840 288x840x840

21 24 26

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

51/- 52/- 55/- 58/- 61/-

33/28 34/29 38/32 41/33 44/34

33/28 36/30 38/32 42/34 44/34

1~ / 50/60 / 220-240/220

160

CMSQ-A

GC_pre2_lowres.pdf 160 30/11/2011 12:31:22

Page 163: DAIKIN General Catalogue 2012

161

CONNECTABLE OUTDOOR UNIT CMSQ200A CMSQ250A

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Total piping length System Actual m

Level difference OU - IU m

Power supply Phase / Frequency / Voltage Hz / V

Outdoor unit

Round flow cassette

Concealed ceiling unit

Individual control

Commercial multi system

161

8 10

20.0 25.0

22.4 28.0

6.60 6.74

5.80 6.83

3.03 3.71

3.86 4.10

4

1,680x635x765 1,680x930x765

159 187

95 171

95 171

78 81

57 59

-5.0~43.0

-20.0~15.0

9.52

15.9 19.1

200

-

3N~ / 50 / 400

161

GC_pre2_lowres.pdf 161 30/11/2011 12:31:22

Page 164: DAIKIN General Catalogue 2012

162

Twin, triple, double twin

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

CONNECTABLE INDOOR UNITS

Indoor units *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F

Dimensions Unit HeightxWidthxDepth mm 246x840x840 288x840x840

Weight Unit kg 23 25

Fan-air fl ow rate Cooling Nom. m³/min -

Heating Nom. m³/min -

Decoration panel Model BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5

Sound power level Cooling High dBA 54 62

Sound pressure level

Cooling High/Nom./Low dBA 36/33/32 44/39/33 45/41/35 45/41/37

Heating High/Nom./Low dBA 36/33/32 44/39/33 45/41/35 45/41/37

Refrigerant Type R-410A

Piping connections

Liquid OD mm -

Gas OD mm -

Drain OD mm -

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor units *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840

Fan-air fl ow rate Cooling Nom. m³/min -

Heating Nom. m³/min -

Weight Unit kg -

Decoration panel Model BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5

Sound power level Cooling High dBA 51 54 58

Sound pressure level

Cooling High/Nom./Low dBA 33/31/28 37/35/32 41/38/35

Heating High/Nom./Low dBA 33/31/28 37/35/32 41/38/35

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Drain OD mm 26

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

*Note: grey cells contain preliminary data

› Seasonal effi ciency, optimized for all seasons › Seasonal smart series already comply with the

EU’s 2014 Eco-Design requirements › Suits computer room applications (EDP) › Re-use of existing R-22 or R-407C technology › Down to -20°C in heating mode › Standard night quiet mode › Maximum piping length up to 75m › Minimum piping length: no limitation › Compatibility with D-BACS

162162

RZQG-L

Seasonal Smart

GC_pre2_lowres.pdf 162 30/11/2011 12:31:23

Page 165: DAIKIN General Catalogue 2012

163

CONNECTABLE INDOOR UNITS

Indoor unit FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8

Casing Colour To be confirmed

Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700

Weight Unit kg 34 45

Decoration panel Model BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0,5)

Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500

Weight kg 4.5 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28

Heating High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28

Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50

Sound power level Cooling High/Nom./Low dBA -/57/- -/61/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34

Heating High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor unit FHQG71C FHQG100C FHQG125C FHQG140C

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690

Weight Unit kg 32 38

Fan - Air flow rate Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24

Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24

Sound power level Cooling Nom. dBA 55 60 62 64

Sound pressure level

Cooling High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38

Heating High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Drain OD mm VP 20 (ID20/OD 24)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit FUQ71B FUQ100B FUQ125B

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm 950x950x198

Weight Unit kg 30 31.0

Fan - Air flow rate Cooling High/Nom./Low m³/min 23.5/16/14 31/25/21 35/27/23

Heating High/Nom./Low m³/min 23.5/16/14 31/25/21 35/27/23

Sound power level Cooling High/Nom./Low dBA 56/51 59/54 60/55

Sound pressure level

Cooling High/Nom./Low dBA 41/38/35 46/42/38 47/43/39

Heating High/Nom./Low dBA 41/38/35 46/42/38 47/43/39

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.90

Drain OD mm ID20 / OD26

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit FAQ71C FAQ100C FAQ125C

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240

Weight Unit kg 13 17 17

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/16/14 26/23/19

To be confirmed

Heating High/Nom./Low m³/min 18/16/14 26/23/19

Sound power level Cooling High/Nom./Low dBA 61/58/56 65/62/58

Heating High/Nom./Low dBA 61/58/56 65/62/58

Sound pressure level

Cooling High/Nom./Low dBA 45/42/40 49/45/41

Heating High/Nom./Low dBA 45/42/40 49/45/41

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220

*Note: grey cells contain preliminary data

Twin, triple, double twin

163163

RZQG-L

GC_pre2_lowres.pdf 163 30/11/2011 12:31:23

Page 166: DAIKIN General Catalogue 2012

164

CONNECTABLE INDOOR UNITS

Indoor unit FDQ125C

Casing Colour Not painted (galvanised)

Dimensions Unit HeightxWidthxDepth mm 300x1,400x700

Required ceiling void > mm 350

Weight Unit kg 45

Decoration panel Model BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm 55x1,500x500

Weight kg 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 39/-/28

Heating High/Nom./Low m³/min 39/-/28

Fan - External static pressure High/Nom. Pa 200/50

Sound power level Cooling High/Nom./Low dBA -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 40/-/33

Heating High/Nom./Low dBA 40/-/33

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor unit FVQ71C FVQ100C FVQ125C FVQ140C

Casing Colour Fresh white

Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350

Weight Unit kg 39 47 47 47

Fan - Air flow rate Cooling High/Nom./Low m³/minTo be confirmed

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA 55/53/50 62/59/56 63/60/58 65/63/60

Sound pressure level

Cooling High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48

Heating High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Name / Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Preliminary

CONNECTABLE INDOOR UNITS

Outdoor unit *RZQG71L7V1 *RZQG100L7V1 *RZQG125L7V1 *RZQG140L7V1 *RZQG71L7Y1 *RZQG100L7Y1 *RZQG125L7Y1 *RZQG140L7Y1

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Fan - Air flow rate Cooling Nom. m³/min - -

Heating Nom. m³/min - -

Sound power level Cooling Nom. dBA 64 66 - 64 66 -

Sound pressure level

Cooling Nom. dBA 48 50 - 48 50 -

Heating Nom. dBA 50 52 - 50 52 -

Night quiet mode Level 1 dBA - -

Operation range Cooling Ambient Min.~Max. °CDB -15.0~50.0 -15.0~50.0

Heating Ambient Min.~Max. °CWB -20.0~15.5 -20.0~15.5

Refrigerant Type R-410A R-410A

Piping

connections

Level difference IU - OU Max. m 30.0 -

IU - IU Max. m - -

Heat insulation - -

Total piping length System Actual m 50 75 50 75

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

*Note: grey cells contain preliminary data

Twin, triple, double twin

164164

RZQG-L

Seasonal Smart

GC_pre2_lowres.pdf 164 30/11/2011 12:31:23

Page 167: DAIKIN General Catalogue 2012

165

Twin, triple, double twin

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

CONNECTABLE INDOOR UNITS

Indoor units *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F

Dimensions Unit HeightxWidthxDepth mm 246x840x840 288x840x840

Weight Unit kg 23 25

Fan-air fl ow rate Cooling Nom. m³/min -

Heating Nom. m³/min -

Decoration panel Model BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5

Sound power level Cooling High dBA 54 62

Sound pressure level

Cooling High/Nom./Low dBA 36/33/32 44/39/33 45/41/35 45/41/37

Heating High/Nom./Low dBA 36/33/32 44/39/33 45/41/35 45/41/37

Refrigerant Type R-410A

Piping connections

Liquid OD mm -

Gas OD mm -

Drain OD mm -

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor units *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840

Fan-air fl ow rate Cooling Nom. m³/min -

Heating Nom. m³/min -

Weight Unit kg -

Decoration panel Model BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm 50x950x950 / 50x950x950 / 130x950x950

Weight kg 5.5 / 5.5 / 11.5

Sound power level Cooling High dBA 51 54 58

Sound pressure level

Cooling High/Nom./Low dBA 33/31/28 37/35/32 41/38/35

Heating High/Nom./Low dBA 33/31/28 37/35/32 41/38/35

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Drain OD mm 26

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

*Note: grey cells contain preliminary data

› Seasonal effi ciency, optimized for all seasons › Re-use of existing R-22 or R-407C technology › Down to -15°C in heating mode › Maximum piping length up to 50m › Minimum piping length: no limitation › Compatibility with D-BACS

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

165165

RZQSG-L

GC_pre2_lowres.pdf 165 30/11/2011 12:31:23

Page 168: DAIKIN General Catalogue 2012

166

CONNECTABLE INDOOR UNITS

Indoor unit FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8

Casing Colour To be confirmed

Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700

Weight Unit kg 34 45

Decoration panel Model BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0,5)

Dimensions HeightxWidthxDepth mm 55x1,100x500 55x1,500x500

Weight kg 4.5 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28

Heating High/Nom./Low m³/min 18/-/15 32/-/23 39/-/28

Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50

Sound power level Cooling High/Nom./Low dBA -/57/- -/61/- -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34

Heating High/Nom./Low dBA 37/-/29 38/-/32 40/-/33 41/-/34

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor unit FHQG71C FHQG100C FHQG125C FHQG140C

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690

Weight Unit kg 32 38

Fan - Air flow rate Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24

Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24

Sound power level Cooling Nom. dBA 55 60 62 64

Sound pressure level

Cooling High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38

Heating High/Nom./Low dBA 38/36/34 42/38/34 44/41/37 46/42/38

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Drain OD mm VP 20 (ID20/OD 24)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

CONNECTABLE INDOOR UNITS

Indoor unit FAQ71C FAQ100C FAQ125C

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240

Weight Unit kg 13 17 17

Fan - Air flow rate Cooling High/Nom./Low m³/min 18/16/14 26/23/19

To be confirmed

Heating High/Nom./Low m³/min 18/16/14 26/23/19

Sound power level Cooling High/Nom./Low dBA 61/58/56 65/62/58

Heating High/Nom./Low dBA 61/58/56 65/62/58

Sound pressure

level

Cooling High/Nom./Low dBA 45/42/40 49/45/41

Heating High/Nom./Low dBA 45/42/40 49/45/41

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220

*Note: grey cells contain preliminary data

Twin, triple, double twin

166166

RZQSG-L

GC_pre2_lowres.pdf 166 30/11/2011 12:31:23

Page 169: DAIKIN General Catalogue 2012

167

CONNECTABLE INDOOR UNITS

Indoor unit FDQ125C

Casing Colour Not painted (galvanised)

Dimensions Unit HeightxWidthxDepth mm 300x1,400x700

Required ceiling void > mm 350

Weight Unit kg 45

Decoration panel Model BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm 55x1,500x500

Weight kg 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 39/-/28

Heating High/Nom./Low m³/min 39/-/28

Fan - External static pressure High/Nom. Pa 200/50

Sound power level Cooling High/Nom./Low dBA -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 40/-/33

Heating High/Nom./Low dBA 40/-/33

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor unit *FVQ71C *FVQ100C *FVQ125C *FVQ140C

Casing Colour Fresh white

Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350

Weight Unit kg 39 47 47 47

Fan - Air flow rate Cooling High/Nom./Low m³/minTo be confirmed

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA 55/53/50 62/59/56 63/60/58 65/63/60

Sound pressure level

Cooling High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48

Heating High/Nom./Low dBA 43/41/38 50/47/44 51/48/46 53/51/48

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Name / Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Preliminary

CONNECTABLE OUTDOOR UNITS

Outdoor unit *RZQSG71LV1 *RZQSG100LV1 *RZQSG125LV1 *RZQSG140LV1 *RZQSG71LY1 *RZQSG100LY1 *RZQSG125LY1 *RZQSG140LY1

Dimensions Unit HeightxWidthxDepth mm 990x940x320 1,430x940x320 990x940x320 1,430x940x320

Weight Unit kg 77 99 77 99

Fan - Air flow rate Cooling Nom. m³/min - -

Heating Nom. m³/min - -

Sound power level Cooling Nom. dBA 64 - 64 -

Sound pressure level

Cooling Nom. dBA 48 55 - 48 55 -

Heating Nom. dBA 50 57 - 50 57 -

Night quiet mode Level 1 dBA - -

Operation range Cooling Ambient Min.~Max. °CDB -5.0~46 -5.0~46

Heating Ambient Min.~Max. °CWB -15~15.5 -15~15.5

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm - -

Gas OD mm - -

Drain OD mm - -

Level difference IU - OU Max. m - -

IU - IU Max. m - -

Heat insulation Both liquid and gas pipes -

Total piping length System Actual m 50 50

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 1~ / 50 / 220-240

*Note: grey cells contain preliminary data

Twin, triple, double twin

167167

RZQSG-L

GC_pre2_lowres.pdf 167 30/11/2011 12:31:23

Page 170: DAIKIN General Catalogue 2012

168

CONNECTABLE INDOOR UNITS

Indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Decoration panel Model

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type

Piping

connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor units

Dimensions Unit HeightxWidthxDepth mm

Fan-air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Weight Unit kg

Decoration panel Model

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Sound power level Cooling High dBA

Sound pressure

level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase / Frequency / Voltage Hz / V

Twin, triple, double twin

Three phase

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

1 Pure white standard panel with grey louvers / 2 Pure white standard panel with white louvers / 3 Pure white auto cleaning panel

› Re-use of existing R-22 or R-407C piping › Down to -15°C in heating mode › Standard night quiet mode › Maximum piping length up to 100m › Maximum installation height difference up to 30m

*Note: grey cells contain preliminary data

168

*FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F

246x840x840 288x840x840

23 25

-

-

BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

54 62

36/33/32 44/39/33 45/41/35 45/41/37

36/33/32 44/39/33 45/41/35 45/41/37

R-410A

9.52

15.9

26

1~ / 50/60 / 220-240/220

*FCQG71F *FCQG100F *FCQG125F *FCQG140F

204x840x840 246x840x840

-

-

-

BYCQ140DW11 / BYCQ140DW1W2 / BYCQ140DGW13

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

51 54 58

33/31/28 37/35/32 41/38/35

33/31/28 37/35/32 41/38/35

R-410A

9.52

15.9

26

1~ / 50/60 / 220-240/220

168

RZQ-C

GC_pre2_lowres.pdf 168 30/11/2011 12:31:23

Page 171: DAIKIN General Catalogue 2012

CONNECTABLE INDOOR UNITS

Indoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYFQ60BAW1

Colour Pure White (RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 230

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS45DJW1 BYBS71DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Fan - External static pressure High/Nom. Pa

Sound power level Cooling High dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP25 (O.D. 32 / I.D. 25)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Low dBA

Heating High/Low dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain VP20 (I.D. 20/O.D. 26)

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

169

*Note: grey cells contain preliminary data

Twin, triple, double twin

Three phase

*FFQ50B9V *FFQ60B9V

286x575x575

17.5

55x700x700

2.7

12.0/8.0 15.0/10.0

12.0/8.0 15.0/10.0

53.0 58.0

36.0/27.0 41.0/32.0

36.0/27.0 41.0/32.0

6.35

12.7

26

FBQ35C8 FBQ50C8 FBQ60C8 FBQ71C8

300x700x700 300x1,000x700

350

25 34

55x800x500 55x1,100x500

3.5 4.5

16/11 18/15

16/11 18/15

100/30

63 57

37/29

37/29

6.35 9.52

9.52 12.70 15.90

VP 25 (OD 32/ID 25)

FHQ50B FHQ60B

195x960x680 195x1,160x680

25 27

13/10 17/13

13/10 16/13

54/49 55/49

54/49 55/49

38/33 39/33

38/33 39/33

6.35

12.70

169169

RZQ-C

GC_pre2_lowres.pdf 169 30/11/2011 12:31:23

Page 172: DAIKIN General Catalogue 2012

170

RZQ-C

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour Fresh white (6.5Y 9.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm VP 20 (ID20/OD 24)

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm ID20 / OD26

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit

Casing Colour To be confirmed

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling High/Nom./Low m³/min

Heating High/Nom./Low m³/min

Sound power level Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Sound pressure level

Cooling High/Nom./Low dBA To be confirmed

Heating High/Nom./Low dBA

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase / Frequency / Voltage Hz / V

CONNECTABLE INDOOR UNITS

Indoor unit FDQ125C

Casing Colour Not painted (galvanised)

Dimensions Unit HeightxWidthxDepth mm 300x1,400x700

Required ceiling void > mm 350

Weight Unit kg 45

Decoration panel Model BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm 55x1,500x500

Weight kg 6.5

Fan - Air flow rate Cooling High/Nom./Low m³/min 39/-/28

Heating High/Nom./Low m³/min 39/-/28

Fan - External static pressure High/Nom. Pa 200/50

Sound power level Cooling High/Nom./Low dBA -/66/-

Sound pressure level

Cooling High/Nom./Low dBA 40/-/33

Heating High/Nom./Low dBA 40/-/33

Refrigerant Type R-410A

Piping connections

Liquid OD mm 9.52

Gas OD mm 15.9

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

170

*Note: grey cells contain preliminary data

Twin, triple, double twin

Three phase

FHQG71C FHQG100C FHQG125C FHQG140C

235x1,270x690 235x1,590x690

32 38

20.5/17/14 28/24/20 31/27/23 34/29/24

20.5/17/14 28/24/20 31/27/23 34/29/24

55 60 62 64

38/36/34 42/38/34 44/41/37 46/42/38

38/36/34 42/38/34 44/41/37 46/42/38

R-410A

9.52

15.9

1~ / 50 / 220-240

FUQ71B FUQ100B FUQ125B

950x950x198

30 31.0

23.5/16/14 31/25/21 35/27/23

23.5/16/14 31/25/21 35/27/23

56/51 59/54 60/55

41/38/35 46/42/38 47/43/39

41/38/35 46/42/38 47/43/39

R-410A

9.52

15.90

1~ / 50 / 220-240

FAQ71C FAQ100C *FAQ125C

Fresh white (6.5Y 9.5/0.5)

290x1,050x238 340x1,200x240 340x1,200x240

13 17 17

18/16/14 26/23/19

18/16/14 26/23/19

61/58/56 65/62/58

61/58/56 65/62/58

45/42/40 49/45/41

45/42/40 49/45/41

R-410A

9.52

15.9

1~ / 50/60 / 220-240/220 15.9 / 1~ / 50/60 / 220-240/220

170

GC_pre2_lowres.pdf 170 30/11/2011 12:31:23

Page 173: DAIKIN General Catalogue 2012

CONNECTABLE OUTDOOR UNITS

Outdoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan - Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Fan - External static pressure Max. Pa

Sound power level Nom. dBA

Operation range Cooling Ambient Min.~Max. °CDB

Heating Ambient Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Level difference IU - OU Max. m

Total piping length System Actual m

Power supply Phase / Frequency / Voltage Hz / V

171

RZQ200C RZQ250C

1,680x930x765

183 184

171

171

78

78

-5.0~46.0

-15.0~15.0

100

-

3N~ / 50 / 380-415

171171

GC_pre2_lowres.pdf 171 30/11/2011 12:31:24

Page 174: DAIKIN General Catalogue 2012

172

Heating & CoolingIndoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Evaporator Air flow rate Cooling l/s

External static pressure Pa

Evaporator piping connections

Condensation drain size

OD mm

Condenser Dimensions Unit HxWxD mm

Weight Unit kg

Casing Colour Light grey

Material Electro-galvanised mild steel

Air flow rate Cooling cfm

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CDB

Sound power level Nom. dBA

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

› Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected

› High efficiency and reliable scroll compressor › Wide operating range › Flat top unit design allows maximum use of

warehouse and container space › Free cooling and fresh air intake possible with optional economiser › Convertible return and supply air: fan can be mounted in two directions › Factory pre-charged refrigerant ensures clean and efficient operation › Belt driven fan enables air volume and static

pressure to be adjusted as required. › Adjustable fan pulley as standard to meet a wide range

of supply air volumes and external static pressures › Anti-corrosion treated coil

Rooftop - heat pump

PLUG AND PLAY INSTALLATION

Indoor unit

Dimensions Packed unit Height mm

Width mm

Depth mm

Weight Unit kg

Packing Weight kg

Fan Air flow rate Cooling Nom. l/s

cfm

Option for UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1

Economiser option

172

UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1

27.340 35.580 44.720 55,690.000 66.820 72.600

24.910 34.790 41.790 53.930 61.690 69.610

8.140 10.780 13.040 16.740 19.650 21.610

7.330 10.840 12.860 15.540 18.580 21.420

3.36 3.30 3.43 3.33 3.40 3.36

3.40 3.21 3.25 3.47 3.32 3.25

1,560 2,030 2,670 3,160 3,445 3,917

147 206

25.4

1,150x1,638x2,063 1,028x2,209x2,113 1,130x2,209x2,113 1,048x2,209x2,670 1,302x2,209x2,670 1,454x2,209x2,670

445 580 610 780 830 970

8,230 12,000 12,100 12,900 20,200 21,200

0~52

-15~20

82 83 87 90

3~/50/380-415

ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1

534

1,440 1,430 1,458

1,144 1,124 1,564

51 42 43 53 54 69

152 140 141 165 166 181

1,560 2,030 2,670 3,160 3,445 3,917

3,300 4,300 5,650 6,700 7,300 8,300

172

Remote Control

UATYQ-CY1

UATYQ-CY1

GC_pre2_lowres.pdf 172 30/11/2011 12:31:24

Page 175: DAIKIN General Catalogue 2012

173

Heating & CoolingIndoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Evaporator Air flow rate Cooling m³/min

External static pressure Pa

Evaporator piping connections

Condensation drain size

OD mm

Condenser Dimensions Unit HxWxD mm

Weight Unit kg

Casing Colour Light grey

Material Electro-galvanised mild steel

Air flow rate Cooling cfm

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Sound power level Nom. dBA

Refrigerant Type

Power supply Phase/Frequency/Voltage Hz/V

› Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected

› Factory pre-charged refrigerant ensures clean and efficient operation › Belt driven fan enables air volume and static

pressure to be adjusted as required. › Flat top unit design allows maximum use of

warehouse and container space › High efficiency and reliable scroll compressor › Anti-corrosion treated coil

Rooftop - heat pump

173

UATYP700AMY1 UATYP850AMY1 UATYPC10AMY1 UATYPC12AMY1

67.406 82.939 101.110 109.609

74.733 92.317 102.290 126.314

29.200 38.160 43.170 48.200

26.220 34.780 41.670 46.800

2.31 2.17 2.34 2.27

2.85 2.65 2.45 2.70

226 263 312 354

294

25.4

1,735x2,250x2,800 1,974x2,252x3,180

1,200 1,350 1,510 1,600

20,000

20~46

-15~20

-

3~/50/380-415

173

Remote Control

UATYP-AY1

UATYP-AY1

GC_pre2_lowres.pdf 173 30/11/2011 12:31:24

Page 176: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 174 30/11/2011 12:31:24

Page 177: DAIKIN General Catalogue 2012

175

THE NEXT GENERATION VRV ... 176

TOTAL SOLUTION CONCEPT 178

VRV OUTDOOR UNITS 180

Air-cooled VRV 180

Heat recovery 180

REYAQ-P 180

REYHQ-P 181

REYQ-P8/P9 182

Branch selector (BS box) 184

BSVQ-P8 184

BSV4/6Q-PV 184

Heat pump 185

RTSYQ-P 185

RXYHQ-P9 186

RXYQ-P9 188

RXYRQ-P 190

RXYSQ-P8V1 191

RXYSQ-P8Y1 191

Heating only 192

RXHQ-P 192

Replacement VRV 194

RQCEQ-P 194

RQYQ-P 194

Water-cooled VRV 198

RWEYQ-P 198

RWEYQ-PR 200

VRV INDOOR UNITS 202

Benefits overview 202

Cassette units 204

FXFQ-P9 204

FXZQ-M9 205

FXCQ-M8 206

FXKQ-MA 207

Concealed ceiling units 208

FXDQ-M9 208

FXDQ-P7 209

FXSQ-P 210

FXMQ-P7 211

FXMQ-MA 212

Wall mounted unit 213

FXAQ-P 213

Ceiling suspended units 214

FXHQ-MA 214

FXUQ-MA 215

Floor standing units 216

FXNQ-P 216

FXLQ-P 217

HOT WATER 218

HXHD-A 218

Accessories for hot water 219

POWERFUL SELECTION PROGRAMMES 221

Xpress, VRV Pro 221

For more information on Options & Accessories, please refer to page 352 of this catalogue.

NEW

GC_pre2_lowres.pdf 175 30/11/2011 12:31:24

Page 178: DAIKIN General Catalogue 2012

176

The next generation VRV …

VRV IV Heat Pump & Heat Recovery* › Personalize your VRV to achieve highest possible seasonal

efficiency and comfort with advanced evaporating &

condensing temperature control

› Perfect heating comfort: continuous heating during

defrost (also on Heat Pump)

› USB commissioning

Available 2nd half 2012

New round flow cassette* › The optional presence sensor adjusts set point or

switches off the unit when nobody is in the room saving

up to 27% of energy

› The optional presence sensor directs air flow away from

people to avoid draught

› Save up to 50% of energy thanks to daily filter cleaning

with optional auto cleaning panel

(Wolverhampton, UK test site)

› The flexibility to adapt the air flow pattern to a

changed interior

*preliminary

PRELIMIN

ARY

GC_pre2_lowres.pdf 176 30/11/2011 12:31:25

Page 179: DAIKIN General Catalogue 2012

177

VRV Heat Pump - RYCQ-A* › For smaller projects, with standard cooling & heating requirements

› Connectable to all VRV indoor units, controls and ventilation

› Total piping length: 300m

› Maximum piping length: 165m

› Range: 8 - 20HP

New ERQ* › Perfect comfort thanks to continuous heating during defrost

› Better acceptance of DX technology to condition fresh air

› Easier integration of ERQ in a total HVAC solution via new Intelligent Touch Manager

*preliminary

* › Contemporary design

› User friendly interface

› Increased flexibility

› USB connection

› Modbus

› Manage up to 2,560 groups of indoor units

› Energy management tools help to prevent energy waste

› Remote refrigerant containment check on VRV

PRELIMIN

ARY

PRELIMIN

ARY

GC_pre2_lowres.pdf 177 30/11/2011 12:31:25

Page 180: DAIKIN General Catalogue 2012

+

22

Total solution concept

The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated climate

control system. Our modular units enable you to select the right mix of equipment and technology to ensure that you

achieve the optimal balance of temperature, humidity and air freshness for the perfect comfort zone with maximum energy

effi ciency and cost eff ectiveness.

HEATING AND COOLING

Wide range of indoor units that fi t

rooms of any size and shape

› Perfect comfort

› Whisper-quiet operation

› Stylish design

› Concealed installation possible

› From individual control to

the management of multiple

buildings

› User friendly touch screen

control

› Remote control & monitoring via

internet

Full control for maximum effi ciency

USER FRIENDLY CONTROL

SYSTEMS

SAVE UP TO 15%

COMPARED TO

TRADITIONAL

SYSTEMS

Cooling

VentilationHeating

Hot water Air curtain

VRV heat recovery system

GC_pre2_lowres.pdf 178 30/11/2011 12:31:25

Page 181: DAIKIN General Catalogue 2012

179

+ ++

VRV OUTDOOR UNITS

Integrated heat pump solution

› Solution for every climate from -25°C to +52°C1

› Flexible to fi t any building

› Top effi ciencies to ensure low

running costs and CO2

emissions

1 Contact your local dealer

› Most effi cient open-door

solution

› Year-round comfort, even on the

most demanding days

› Free air curtain heating possible

› Heat is reclaimed between out

and indoor air

› Free cooling possible

› Optimum control of humidity

› For one room or your entire

building

› Free hot water production

possible

› Possibility to connect to solar

panels

› Possible applications: bathrooms,

sinks, under fl oor heating and

radiators

› Hot water up to 80°C

A highly effi cient solution to

doorway climate separation

Create a high-quality indoor

environment

Use heat pump technology to

produce hot water

AIR SEPARATION THROUGH

AIR CURTAINS

VENTILATION HOT WATER

SAVE UP TO 40%

THANKS TO

LOWER COOLING

AND HEATING

REQUIREMENTS

SAVE UP TO 17%

COMPARED TO A

GAS BOILER

SAVE UP TO 72%

COMPARED TO

AN ELECTRIC AIR

CURTAIN

GC_pre2_lowres.pdf 179 30/11/2011 12:31:26

Page 182: DAIKIN General Catalogue 2012

180

Heat recoveryOutdoor unit

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Indoor index connection

Min.

Nom.

Max.

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Hot water production

Min.~Max. °CDB -20~20 / 24 (1) (Space heating)

Min.~Max. °CDB -20~43 (Domestic hot water)

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 40 (Outdoor unit in highest position)/ 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

› Temperature control, fresh air provision, Biddle air curtains and hot water production all integrated in a single system

› Heat recovery maximises energy efficiency with COPs of up to 8 possible! › Free heating provided by transferring heat from areas

requiring cooling to areas requiring heating or hot water › Perfect comfort: simultaneous heating and cooling › Compact size leaves maximum floorspace › Fits any building with either outdoor or indoor installation

possible (high external static pressure up to 78.4Pa) › The ability to control each conditioned zone individually keeps

VRV system running costs to an absolute minimum › Spread your installation cost by phased installation › Wide range of indoor units: 14 different models

VRVIII heat recovery, with connection to heating

only hydrobox

(1) Field setting

180

REYAQ10P REYAQ12P REYAQ14P REYAQ16P

10 12 14 16

28 33.5 40 45

31.5 37.5 45 50

7.09 8.72 11.4 14.1

7.38 8.84 11.0 12.8

3.95 3.84 3.51 3.19

4.27 4.24 4.09 3.91

21 26 30 34

125 150 175 200

250 300 350 400

325 390 455 520

1,680x1,300x765

331 339

78 80 83 84

58 60 62 63

-5~43

-20~15.5

9.52 12.7

22.2 28.6

19.1 22.2

100

300

3~/50/380-415

25 40

180

REYAQ-P

REYAQ-P

GC_pre2_lowres.pdf 180 30/11/2011 12:31:26

Page 183: DAIKIN General Catalogue 2012

181

Heat recoveryOutdoor system

System Outdoor unit module 1 REMQ8P9 REMQ10P8 REMHQ12P8

Outdoor unit module 2 REMQ8P9 REMHQ12P8

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

› Top energy efficiency in Daikin heat recovery range, thanks to the specially designed 8HP modular unit and 12HP high COP modular unit

4.40

4.30

4.20

4.10

3.90

3.80

3.70

3.6016 20 22 24

+ 11

%

High COP range

Small footprint range

CO

P

› Wide range of indoor units: 14 different models › Continuous heating (resulting in a higher integrated heating capacity) › ‘High sensible mode’: allows the VRV system to work with increased sensible

capacity in cooling mode, resulting in higher efficiency and improved comfort › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Wide piping flexibility: maximum piping length:

165m, total piping length: 1,000m › The ability to control each conditioned zone individually keeps

VRV system running costs to an absolute minimum › Only those areas calling for air conditioning need to be cooled or heated;

the system can be shut down completely in unoccupied rooms. › Quick cool/heat change over › Improved refrigerant containment check › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Possibility to extend the operation range in cooling down to -20°C

VRVIII heat recovery, high COP combination

181

REYHQ16P REYHQ20P REYHQ22P REYHQ24P

16 20 22 24

45.0 56.0 61.5 67.0

50.0 62.5 69.0 75.0

10.5 13.9 16.0 17.2

11.5 14.3 16.3 17.2

4.29 4.04 3.84 3.89

4.36 4.24 4.37

34 43 47 52

82 85 87

62 64 66

12.7 15.9

28.6 34.9

1,000

3N~/50/380-415

50 63 80

REMQ8P9 REMQ10P8 REMHQ12P8

1,680x930x765 1,680x1,300x765

204 254 331

-5~43

-20~15

3~/50/380-415 3N~/50/380-415

- 40

181

REYHQ16P

REYHQ-P

GC_pre2_lowres.pdf 181 30/11/2011 12:31:26

Page 184: DAIKIN General Catalogue 2012

182

› Increased EER/COP thanks to the redesigned 8 and 12HP stand alone units and 8HP modular unit

› Wide range of outdoor units: from 8 to 48HP in 2HP increment steps (21 system combinations)

› Its ability to run no less than 64 indoor units in heat recovery mode cannot at present be matched by other comparable systems

› Flexible combination of outdoor units: small footprint combination, high COP combination or any other combination of your choice

› Continuous heating (resulting in a higher integrated heating capacity) › ‘High sensible mode’: allows the VRV system to work with

increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort

› Easy installation thanks to automatic refrigerant charging operation, automatic test operation

› Wide piping flexibility: maximum piping length: 165m, total piping length: 1,000m

› The ability to control each conditioned zone individually keeps VRV system running costs to an absolute minimum

› Only those areas calling for air conditioning need to be cooled or heated; the system can be shut down completely in unoccupied rooms.

› Quick cool/heat change over › Improved refrigerant containment check › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Possibility to extend the operation range in cooling down to -20°C

VRVIII heat recovery, small footprint combination

REYQ-P8/P9

Stand alone units

REYQ8P9

���� ���������REYQ10P8

REYQ12P9

REYQ14P8

REYQ16P8

Modular units

REMQ8P9

���� ���������REMQ10P8

REMQ12P8

REMQ14P8

REMQ16P8

REYQ-P8/P9

Stand alone units

REYQ8P9

���� ���������REYQ10P8

REYQ12P9

REYQ14P8

REYQ16P8

Modular units

REMQ8P9

REMQ10P8

REMQ12P8

REMQ14P8

REMQ16P8

182

8 10 12 14 16 18 20 22 24 26 28

��

��

�� �� � �

� � � �

� �

30 32 34 36 38 40 42 44 46 48

� �� � �

� � � �� �� � � � � � � � � �

182

REYQ8-16P8/P9

REYQ-P8/P9

GC_pre2_lowres.pdf 182 30/11/2011 12:31:27

Page 185: DAIKIN General Catalogue 2012

Heat recoveryOutdoor system

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor system

System Outdoor unit module 1 REMQ8P9 REMQ10P8 REMQ12P8 REMQ10P8 REMQ12P8 REMQ14P8 REMQ16P8

Outdoor unit module 2 REMQ10P8 REMQ12P8 REMQ16P8

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound power level Cooling Nom dBA

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Oil equalizing OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor system

System Outdoor unit module 1 REMQ8P9 REMQ10P8 REMQ12P8 REMQ10P8 REMQ12P8 REMQ14P8 REMQ16P8

Outdoor unit module 2 REMQ10P8 REMQ12P8 REMQ16P8

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound power level Cooling Nom dBA

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Oil equalizing OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

183

(1) Field setting

REYQ8P9 REYQ10P8 REYQ12P9 REYQ14P8 REYQ16P8

8 10 12 14 16

22.4 28.0 33.5 40.0 45.0

25.0 31.5 37.5 45.0 50.0

5.20 7.09 8.72 11.4 14.1

5.71 7.38 8.84 11.0 12.8

4.31 3.95 3.84 3.51 3.19

4.38 4.27 4.24 4.09 3.91

17 21 26 30 34

1,680x1,300x765

331 339

78 78 80 83 84

58 60 62 63

-20 (1) / -5~43

-20~15.5

9.52 12.7

19.1 22.2 28.6

15.9 19.10 22.2

165

1,000

3~/50/380-415

20 25 40

REYQ18P9 REYQ20P9 REYQ22P8 REYQ24P8 REYQ26P8 REYQ28P8 REYQ30P8 REYQ32P8

18 20 22 24 26 28 30 32

50.4 55.9 61.5 67.0 73.0 78.5 85.0 90.0

56.5 62.5 69.0 75.0 81.5 87.5 95.0 100

12.7 14.9 17.0 19.2 21.8 23.8 26.6 28.4

13.4 15.2 17.1 18.9 20.6 22.3 24.2 25.8

3.97 3.75 3.62 3.49 3.35 3.29 3.19 3.16

4.22 4.11 4.04 3.97 3.96 3.92 3.87

39 43 47 52 56 60 64

81 83

15.9 19.1

28.6 34.9

22.2 28.6

19.1

165

1,000

3~/50/380-415

45 50 60 70

REYQ34P9 REYQ36P9 REYQ38P8 REYQ40P8 REYQ42P8 REYQ44P8 REYQ46P8 REYQ48P8

34 36 38 40 42 44 46 48

95.4 101 107 112 118 124 130 135

107 113 119 125 132 138 145 150

26.9 29.1 31.2 33.4 35.8 38.0 40.8 42.6

26.3 28.1 30.0 31.8 33.5 35.2 37.1 38.7

3.55 3.47 3.43 3.35 3.29 3.26 3.18 3.16

4.07 4.02 3.96 3.93 3.94 3.92 3.90 3.87

64

84 85

19.1

34.9 41.3

28.6 34.9

19.1

165

1,000

3~/50/380-415

80 90 100 110

REMQ8P9 REMQ10P8 REMQ12P8 REMQ14P8 REMQ16P8

1,680x930x675 1,680x1,240x765

204 254 334

-20 (1) / -5~43

-20 ~ 15.5

3~/50/380-415

183183

GC_pre2_lowres.pdf 183 30/11/2011 12:31:27

Page 186: DAIKIN General Catalogue 2012

184

Indoor unit

Power input Cooling Nom. kW

Heating Nom. kW

Maximum number of connectable indoor units

Maximum number of connectable indoor units per branch

Number of branches

Maximum capacity index of connectable indoor units

Maximum capacity index of connectable indoor units per branch

Casing Material Galvanised steel plate

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Piping connections

Outdoor unit Liquid Type/OD mm Brazing connection/12.7 Brazing connection/15.9

Gas Type/OD mm Brazing connection/28.6

Discharge gas Type/OD mm Brazing connection/19.1 Brazing connection/28.6

Indoor unit Liquid Type/OD mm Brazing connection/9.5

Gas Type/OD mm Brazing connection/15.9

Sound absorbing thermal insulation Foamed polyurethane, frame resisting needle felt

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Faster installation thanks to a reduced number of brazing points and wiring › Allows individual cool / heat switching for up to 4/6 groups of indoor units › Maximum design flexibility because individual and multi boxes can be combined in one system › Low built-in height › No drain piping needed

Multi branch selector for VRV heat recovery

Indoor unit

Power input Cooling Nom. kW

Heating Nom. kW

Maximum number of connectable indoor units

Maximum capacity index of connectable indoor units

Casing Material Galvanised steel plate

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Piping connections

Outdoor unit Liquid Type/OD mm Brazing connection/9.5

Gas Type/OD mm Brazing connection/15.9 Brazing connection/15.9 Brazing connection/22.2

Discharge gas Type/OD mm Brazing connection/12.7 Brazing connection/12.7 Brazing connection/19.1

Indoor unit Liquid Type/OD mm Brazing connection/9.5 Brazing connection/9.5

Gas Type/OD mm Brazing connection/15.9 Brazing connection/22.2

Sound absorbing thermal insulation Foamed polyurethane, frame resisting needle felt

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Allows individual cool / heat switching for 1 group of indoor units › Maximum design flexibility because individual and multi boxes can be combined in one system › Low built-in height › No drain piping needed › Allows multi tenant applications (option PCB required)

Individual branch selector for VRV heat recovery

184

BSV4Q100PV BSV6Q100PV

0.020 0.030

0.020 0.030

24 36

6

4 6

400 600

100

209x1,053x635 209x1,577x635

60 89

1~/50/220-240

15

BSVQ100P8 BSVQ160P8 BSVQ250P8

0.005

0.005

6 8

20<x≤100 100<x≤160 160<x≤250

207x388x326

12 15

1~/50/220-240

15

184

BSV4Q100PV

BSV4/6Q-PV

BSVQ100-250P8

BSVQ-P8

GC_pre2_lowres.pdf 184 30/11/2011 12:31:27

Page 187: DAIKIN General Catalogue 2012

185

Heating & CoolingOutdoor system

System Outdoor unit module 1 RTSQ10P RTSQ14P RTSQ16P RTSQ8P

Outdoor unit module 2 RTSQ12P

Function unit BTSQ20P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Max./Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Oil equalizing OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (2) Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB,6°CWB;

equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (3) Heating: Indoor temp. 20°CDB; outdoor temp. -10°CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m;

combined indoor unit: FXFQ50P x 5 units

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

› First system in the industry developed for heating operation in low ambient conditions, making it suitable for single source heating

› Extended operation range down to -25°C in heatingHEATING

20

10

0

-5

-10

-15

-20

-25

30

VRV III-C

+15.5 °CWB

-25 °CWB

-20 °CWB

VRV III

+15.5 °CWB

› High COP values at low ambients thanks to two stage compression technology (COP values of 3.0 and more at -10°C)

› Improved comfort thanks to shorter defrost time › Shorter heat up time compared to standard VRVIII heat pump › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Connectable to all VRV indoor units, ventilation and control systems

VRVIII heat pump, optimised for heating

185

RTSYQ10P RTSYQ14P RTSYQ16P RTSYQ20P

-

10 14 16 20

28.0 (1) 40.0 (1) 45.0 (1) 55.9 (1)

31.50 (2) / 28.0 (3) 45.0 (2) / 40.0 (3) 50.0 (2) / 45.0 (3) 62.5 (2) / 56.0 (3)

7.90 12.6 14.9 15.4

7.70 11.3 12.9 15.3

3.54 3.17 3.02 3.63

4.09 3.98 3.88 4.01

21 30 34 43

62/60 63/61 65/63

9.52 12.7 15.9

22.2 28.6

- 19.1

165

500

3~/50/380-415

25 35 40 50

RTSQ8P RTSQ10P RTSQ12P RTSQ14P RTSQ16P BTSQ20P

1,680x930x765 1,680x1,240x765 1,570x460x765

205 257 338 344 110

-5 ~ 46

-25 ~ 15.5

3~/50/380-415

25 35 40 20

185

RTSYQ14-16P

RTSYQ-P

GC_pre2_lowres.pdf 185 30/11/2011 12:31:27

Page 188: DAIKIN General Catalogue 2012

186

› Top energy efficiency in Daikin heat pump range, thanks to the specially designed 8HP unit and 12HP high COP unit › ‘High sensible mode’: allows the VRV system to work with increased sensible capacity in

cooling mode, resulting in higher efficiency and improved comfort › Easy installation thanks to automatic refrigerant charging operation, automatic test operation › Refrigerant containment check › Flexible combination of outdoor units: small footprint combination, high COP combination or any other combination of your choice › High external static pressure (up to 78.4Pa) allows indoor installation › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Wide piping flexibility: maximum piping length: 165m, total piping length: 1,000m › All indoor units can be individually controlled › Spread your installation cost by phased installation › Wide range of indoor units: 14 different models

VRVIII heat pump, high COP combination

186186

RXYHQ20-22P9

RXYHQ-P9

GC_pre2_lowres.pdf 186 30/11/2011 12:31:28

Page 189: DAIKIN General Catalogue 2012

Heating & CoolingOutdoor system

System Outdoor unit module 1 RXYHQ12P9

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor system

System Outdoor unit module 1 RXYQ8P9 RXYQ10P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9

Outdoor unit module 2 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9

Outdoor unit module 3 RXYQ8P9 RXYQ10P9 RXYHQ12P9

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

187

HP 12 16 18 20 22 24 26 28 30 32 34 36

High COP combination

combination 12 8 + 8 8 + 10 8 + 12 10 + 12 8 + 8 + 8 8 + 8 + 10 8+10+10 8+10+12 8+12+12 10+12+12 12+12+12

COP 4.37 4.50 4.27 4.42 4.24 4.50 4.34 4.44 4.31 4.40 4.29 4.37

EER 3.89 4.29 4.00 4.05 3.84 4.29 4.09 4.12 3.96 3.99 3.85 3.89

Small footprint combination

combination 12 16 18 8 + 12 10 + 12 12 + 12 8 + 18 10 + 18 12 + 18 14 + 18 16 + 18 18 + 18

COP 3.97 3.88 3.69 4.18 4.04 3.97 3.94 3.83 3.81 3.83 3.79 3.69

EER 3.48 3.17 3.02 3.80 3.62 3.49 3.41 3.26 3.20 3.11 3.09 3.02

RXYHQ12P9

12

33.5

37.5

8.61

8.58

3.89

4.37

26

1,680x1,240x765

281

80

60

-5.0~43.0

-20.0~15.0

12.7

28.6

165

1,000

3N~/50/400

25

RXYHQ16P9 RXYHQ18P9 RXYHQ20P9 RXYHQ22P9 RXYHQ24P9 RXYHQ26P9 RXYHQ28P9 RXYHQ30P9 RXYHQ32P9 RXYHQ34P9 RXYHQ36P9

-

16 18 20 22 24 26 28 30 32 34 36

45.00 49.00 55.90 61.50 67.00 71.40 77.00 82.50 89.00 94.00 98.00

50.00 56.50 62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00

10.49 12.25 13.80 16.02 15.62 17.46 18.69 20.83 22.31 24.42 25.19

11.11 13.23 14.14 16.27 16.67 18.78 19.82 21.81 23.18 24.94 25.86

4.29 4.00 4.05 3.84 4.29 4.09 4.12 3.96 3.99 3.85 3.89

4.50 4.27 4.42 4.24 4.50 4.34 4.44 4.31 4.40 4.29 4.37

34 39 43 47 52 56 60 64

82 83 85

60 61 62 63 64 65

12.7 15.9 19.1

28.6 34.9 41.3

165

1,000

3N~/50/400

50 63 80

RXYQ8P9 RXYQ10P9

1,680x930x765

187 240

78

57 58

-5.0~43.0

-20~15

3N~/50/400

25

187187

+16%

GC_pre2_lowres.pdf 187 30/11/2011 12:31:28

Page 190: DAIKIN General Catalogue 2012

188

› Compact size leaves maximum floorspace › ‘High sensible mode’: allows the VRV system to work with

increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort

› Easy installation thanks to automatic refrigerant charging operation, automatic test operation

› Refrigerant containment check › Flexible combination of outdoor units: small footprint combination,

high COP combination or any other combination of your choice › High external static pressure (up to 78.4Pa) allows indoor installation › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Wide piping flexibility: maximum piping length:

165m, total piping length: 1,000m › All indoor units can be individually controlled › Spread your installation cost by phased installation › Wide outdoor unit range: from 5 to 54HP via 1 single refrigerant circuit › Wide range of indoor units: 14 different models

VRVIII heat pump, small footprint combination

188188

RXYQ-P9

RXYQ44-46-48P9

GC_pre2_lowres.pdf 188 30/11/2011 12:31:28

Page 191: DAIKIN General Catalogue 2012

Heating & CoolingOutdoor unit

System Outdoor unit module 1 RXYQ5P9 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ14P9 RXYQ16P9 RXYQ18P9

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

APF

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ14P9 RXYQ16P9 RXYQ18P9

Outdoor unit module 2 RXYQ12P9 RXYQ18P9

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

APF

Maximum number of connectable indoor units

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ14P9 RXYQ16P9 RXYQ18P9

Outdoor unit module 2 RXYQ12P9 RXYQ18P9

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

APF

Maximum number of connectable indoor units

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

189

RXYQ5P9 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ14P9 RXYQ16P9 RXYQ18P9

5 8 10 12 14 16 18

14.0 22.4 28.0 33.5 40.0 45.0 49.0

16.0 25.0 31.5 37.5 45.0 50.0 56.5

3.52 5.22 7.42 9.62 12.4 14.2 16.2

4.00 5.56 7.70 9.44 11.30 12.90 15.30

3.98 4.29 3.77 3.48 3.23 3.17 3.02

4.00 4.50 4.09 3.97 3.98 3.88 3.69

5.0 5.4 5 4.6 4.4 4.2

10 17 21 26 30 34 39

1,680x635x765 1,680x930x765 1,680x1,240x765

159 187 240 316 324

72 78 80 83

54 57 58 60 63

-5.0~43.0

-20~15

9.52 12.7 15.9

15.9 19.1 22.2 28.6

165

1,000

3N~/50/400

16 25 40

RXYQ20P9 RXYQ22P9 RXYQ24P9 RXYQ26P9 RXYQ28P9 RXYQ30P9 RXYQ32P9 RXYQ34P9 RXYQ36P9

20 22 24 26 28 30 32 34 36

55.90 61.50 67.00 71.40 77.00 82.50 89.00 94.00 98.00

62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00

14.71 16.99 19.20 20.94 23.62 25.78 28.62 30.42 32.45

14.95 17.08 18.89 20.69 22.98 24.67 26.63 28.23 30.62

3.80 3.62 3.49 3.41 3.26 3.20 3.11 3.09 3.02

4.18 4.04 3.97 3.94 3.83 3.81 3.83 3.79 3.69

4.9 4.8 4.6 4.5 4.4 4.3 4.2

43 47 52 56 60 64

83 85 86

62 63 64 65 66

15.9 19.1

28.6 34.9 41.3

165

1,000

3N~/50/400

50 63 80

RXYQ38P9 RXYQ40P9 RXYQ42P9 RXYQ44P9 RXYQ46P9 RXYQ48P9 RXYQ50P9 RXYQ52P9 RXYQ54P9

38 40 42 44 46 48 50 52 54

105.00 111.00 116.00 120.00 126.00 132.00 138.00 143.00 147.00

119.00 126.00 132.00 138.00 145.00 151.00 158.00 163.00 170.00

30.61 33.23 35.37 36.92 39.75 42.04 44.81 46.58 48.68

30.13 32.39 34.20 35.94 38.26 39.95 41.91 43.47 45.95

3.43 3.34 3.28 3.25 3.17 3.14 3.08 3.07 3.02

3.95 3.89 3.86 3.84 3.79 3.78 3.77 3.75 3.70

4.6 4.5 4.4 4.3 4.2

64

86 87 88

66 67 68

19.1

41.3

165

1,000

3N~/50/400

100 125

189189

GC_pre2_lowres.pdf 189 30/11/2011 12:31:29

Page 192: DAIKIN General Catalogue 2012

190

› Innovative VRV technology combined with stylish and silent indoor units › Wide range of indoor units: either connect VRV or stylish

indoor units such as Daikin Emura, Nexura ... › Up to 39 indoor units can be connected to a 18 HP unit › High external static pressure (up to 78.4Pa) allows indoor installation › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › All indoor units can be individually controlled › Spread your installation cost by phased installation

VRVIII heat pump, with connection to stylish indoor

units

Daikin Emura

Including connection to

Nexura

Connectable indoor units15 class 20 class 25 class 35 class 42 class 50 class 60 class 71 class

Daikin Emura - Wall mounted unit - - FTXG25JW/A FTXG35JW/A - FTXG50JW/A - -

Wall mounted unit CTXS15K FTXS20K FTXS25K CTXS35K - - - -

- FTXS20J FTXS25J FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G

Nexura - Floor standing unit - - FVXG25K FVXG35K - FVXG50K - -

Floor standing unit - - FVXS25F FVXS35F - FVXS50F - -

Flexi type unit - - FLXS25B FLXS35B - FLXS50B - -

Slim concealed ceiling unit - - FDXS25E FDXS35E - FDXS50C FDXS60C -

Concealed ceiling unit - - - FBQ35C - FBQ50C FBQ60C -

4-way blow ceiling mounted cassette (600x600) - - FFQ25B9V FFQ35B9V - FFQ50B9V FFQ60B9V -

Round flow cassette - - - FCQG35F - FCQG50F FCQG60F -

Ceiling suspended cassette - - - FHQ35B - FHQ50B FHQ60B -

All VRV indoor units in all available classes

Heating & CoolingOutdoor unit

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

190

RXYRQ8P RXYRQ10P RXYRQ12P RXYRQ14P RXYRQ16P RXYRQ18P

8 10 12 14 16 18

22.4 28.0 33.5 40.0 45.0 49.0

25.0 31.5 37.5 45.0 50.0 56.5

5.09 7.11 9.23 11.40 13.50 15.30

5.56 7.70 9.44 11.30 12.90 15.30

4.40 3.94 3.63 3.61 3.33 3.20

4.50 4.09 3.97 3.98 3.88 3.69

17 21 26 30 34 39

1,680x930x765 1,680x1,240x765

187 240 316 324

78 80 83

57 58 60 63

-5.0~43.0

-20.0~15.0

9.52 12.7 15.9

19.1 22.2 28.6

250

3N~/50/400

25 40

190

RXYRQ8-12P

RXYRQ-P

GC_pre2_lowres.pdf 190 30/11/2011 12:31:29

Page 193: DAIKIN General Catalogue 2012

191

Heating & CoolingOutdoor unit

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A R-410A

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position) 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

› For residential and light commercial applications › Energy efficient heating system based on air source heat pump technology › Low energy bills and low CO

2 emissions

› Possibility to connect up to 9 indoor units › All indoor units can be individually controlled and do not need

to be installed in the same room or even at the same time. › Wide range of indoor units: either connect VRV or stylish

indoor units such as Daikin Emura, Nexura ... › Possibility to combine different types of indoor units:

wall mounted, floor standing, concealed ceiling, ceiling suspended, round flow or 4-way blow cassettes

› Small capacities: 4, 5 & 6HP › Slim design for flexible installation › 3 steps in night quiet mode: step 1: 47dBA, step 2: 44 dBA, step 3: 41 dBA › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Possibility to limit peak power consumption between 30 and

80%, for example during periods with high power demand

VRVIII-S heat pump

(1) In case VRV indoor units are connected | (2) In case RA indoor units are connected

191

RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1

4 5 6 4 5 6

11.2 14.0 15.5 11.2 14.0 15.5

12.5 16.0 18.0 12.5 16.0 18.0

2.81 3.51 4.53 2.89 3.61 4.65

2.74 3.86 4.57 2.82 3.97 4.70

3.99 3.99 3.42 3.88 3.33

4.56 4.15 3.94 4.43 4.03 3.83

8 (1) / 6 (2) 10 (1) / 8 (2) 13 (1) / 9 (2) 8 (1) / 6 (2) 10 (1) / 8 (2) 13 (1) / 9 (2)

1,345x900x320 1,345x900x320

120 120

66 67 69 66 67 69

50 51 53 50 51 53

52 53 55 52 53 55

-5~46 -5~46

-20~15.5 -20~15.5

9.52 9.52

15.9 (1) / 19.1 (2) 15.9 (1) / 19.1 (2) 19.1 (1)(2) 15.9 (1) / 19.1 (2) 15.9 (1) / 19.10 (2) 19.1 (1)(2)

150 150

300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2)

1N~/50/220-240 3N~/50/380-415

32.0 16.0

191

RXYSQ-P8V1RXYSQ-P8Y1

RXYSQ-P8V1RXYSQ-P8Y1

GC_pre2_lowres.pdf 191 30/11/2011 12:31:29

Page 194: DAIKIN General Catalogue 2012

192

› Energy efficient heating system based on air source heat pump technology › Low energy consumption and low CO

2 emmisions

› The ability to control each conditioned zone individually keeps VRV® system running costs to an absolute minimum

› Temperature control, fresh air provision and Biddle air curtains all integrated in a single system

› Perfect comfort: faster response than traditional heating systems and a constant indoor temperature

› Wide range of indoor units: 14 different models › Easy management of the yearly energy cost thanks

to a wide range of control possibilities › Spread your installation cost by phased installation › No need for fuel storage tanks or pumps › Wide outdoor unit range: from 25 to 170 kW › Easy installation thanks to automatic refrigerant

charging operation, automatic test operation › Easy compliance with F-gas regulation thanks to

automated refrigerant containment check › Compact size leaves maximum floorspace › Fits any building with either outdoor or indoor installation

possible (high external static pressure up to 78.4Pa) › 2 steps in night quiet mode: step 1: 50 dBA, step 2: 45 dBA › Wide piping flexibility: maximum piping length:

165m, total piping length: 1,000m

VRV®III heating only

192192

RXHQ-P9

RXHQ44-46-48P

GC_pre2_lowres.pdf 192 30/11/2011 12:31:29

Page 195: DAIKIN General Catalogue 2012

Heating onlyOutdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index

connection

Min.

Nom.

Max.

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound pressure level Heating Nom. dBA

Operation range Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping

connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Outdoor unit module 2 RXHQ12P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index connection

Min.

Nom.

Max.

Sound pressure level Heating Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RXHQ8P RXHQ10P RXHQ12P RXHQ8P RXHQ10P RXHQ12P RXHQ14P RXHQ16P RXHQ18P

Outdoor unit module 2 RXHQ12P RXHQ18P

Capacity range HP

Heating capacity Nom. kW

Heating Nom. kW

COP

Maximum number of connectable indoor units

Indoor index connection

Min.

Nom.

Max.

Sound pressure level Heating Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

193

RXHQ8P9 RXHQ10P9 RXHQ12P9 RXHQ14P9 RXHQ16P9 RXHQ18P9

8 10 12 14 16 18

25.0 31.5 37.5 45.0 50.0 56.5

5.56 7.70 9.44 11.30 12.90 15.30

4.50 4.09 3.97 3.98 3.88 3.69

17 21 26 30 34 39

100 125 150 175 200 225

200 250 300 350 400 450

260 325 390 455 520 585

1,680x930x765 1,680x1,240x765

187 240 316 324

61 64 67

-20.0~15.0

9.52 12.7 15.9

19.1 22.2 28.6

165

1,000

3N~/50/400

25 40

RXHQ20P9 RXHQ22P9 RXHQ24P9 RXHQ26P9 RXHQ28P9 RXHQ30P9 RXHQ32P9 RXHQ34P9 RXHQ36P9

20 22 24 26 28 30 32 34 36

62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00

14.95 17.08 18.89 20.69 22.98 24.67 26.63 28.23 30.62

4.18 4.04 3.97 3.94 3.83 3.81 3.83 3.79 3.69

43 47 52 56 60 64

250 275 300 325 350 375 400 425 450

500 550 600 650 700 750 800 850 900

650 715 780 845 910 975 1,040 1,105 1,170

66 67 68 69 70

15.9 19.1

28.6 34.9 41.3

165

1,000

3N~/50/400

50 63 80

RXHQ38P9 RXHQ40P9 RXHQ42P9 RXHQ44P9 RXHQ46P9 RXHQ48P9 RXHQ50P9 RXHQ52P9 RXHQ54P9

38 40 42 44 46 48 50 52 54

119.00 126.00 132.00 138.00 145.00 151.00 158.00 163.00 170.00

30.13 32.39 34.20 35.94 38.26 39.95 41.91 43.47 45.95

3.95 3.89 3.86 3.84 3.79 3.78 3.77 3.75 3.70

64

475 500 525 550 575 600 625 650 675

950 1,000 1,050 1,100 1,150 1,200 1,250 1,300 1,350

1,235 1,300 1,365 1,430 1,495 1,560 1,625 1,690 1,755

69 70 71 72

19.1

41.3

165

1,000

3N~/50/400

100 125

193

Power input - 50Hz

Power input - 50Hz

Power input - 50Hz

193

GC_pre2_lowres.pdf 193 30/11/2011 12:31:30

Page 196: DAIKIN General Catalogue 2012

TECHNOLOGIES OF VRVIII-Q?

REDUCED PRESSURE

As R-22 VRV systems used to work on a lower pressure than R-410A

systems / thus the copper refrigerant piping was also designed for

these lower pressures. Therefore the Replacement VRV (VRVIII-Q)

must operate at lower pressures than the standard VRVIII series.

However thanks to the sub cool circuit a high effi ciency level can

be kept even with the lower pressures.

Pressure

Enthalpy

3.8 MPa

3.3 MPa

Decompression to 3.3MPa(s) R-22 existing piping can be used

Extra sub cool circuit high COP

REFRIGERANT PIPE CLEANING

When replacing an air conditioning system, the piping is normally

replaced as well since traces of old refrigerant and oil mixed with

the oil and refrigerant of the new system can cause the equipment

to malfunction.

In order to allow re-use of existing R-22 piping with an R-410A

system Daikin developed a technology to capture and retain

the contamination left in the refrigerant piping. The refrigerant

including the remaining oil from the R-22 system is fi ltered in

the outdoor unit and the contamination is deposited

in the outdoor unit. Daikin is the fi rst manufacturer in

the industry to develop this combination of automatic

charging and refrigerant pipe cleaning function.

I ndoor

Temperature sensor

Temperature sensor

Pressure sensor

Anti-reverse valve

Change over valve

Catcher

Contamination is collected by the power of the refrigerant gas

THE DAIKIN SOLUTION TO R-22 PHASE-OUTReplace your R-22 / R-407C outdoor unit with R-410A technology, but keep your refrigerant piping and in

some cases your indoor units1.

replace

replace*

replace

KEEP

1. Replace outdoor unit

2. Replace BS-boxes (in case of H/R)

3. Replace indoor units (check with your local dealer if needed)

4. The system will automatically clean the piping & charge the correct amount of R-410A refrigerant

* When R-22 indoors are K-series or later, it is possible to keep the indoor units.

Replacement VRV

194

RQCEQ-PRQYQ-P

~~ ~~

}

}A

A

B

B

GC_pre2_lowres.pdf 194 30/11/2011 12:31:30

Page 197: DAIKIN General Catalogue 2012

INCREASED EFFICIENCY

Upgrading an old R-22 system to a Replacement VRVsystem will

result in increased system effi ciency. Effi ciency gains of more than

25% can be realized, by virtue of technological developments in

heat pump technology and the more effi cient R-410A refrigerant.

Increased energy effi ciency equals lower energy consumption,

subsequent lower energy costs and lower CO2 emissions.

EER of a 10 HP system COP of a 10 HP system

40% MORE EFFICIENT 25% MORE EFFICIENT

ENVIRONMENTAL AWARENESS

R-410A not only has a zero ozone depletion potential, it is also

proven to be more energy effi cient than R-22.

FAST INSTALLATION

It is not necessary to remove the existing piping and even the

indoor units can remain (depending on type of indoor unit).

The outdoor unit automatically charges the refrigerant and

cleans the refrigerant piping. This unique Daikin feature makes

the installation time even shorter.

LIMITED AND PLANNED-DOWNTIME

As the refrigerant piping can be maintained the installation is

less intrusive and less time consuming than for a completely

new system. Moreover, downtime can be carefully planned:

whereas if a problem occurs when not enough reclaimed R-22

is available, a long and unplanned downtime can be the result.

LIMITED AND PHASED INVESTMENT COST

It is possible to spread the various stages of replacement over

a certain period of time because the indoor units can remain

in most cases. The air conditioning replacement therefore,

can be incorporated in the general refurbishment schedule of

the building and the investment cost can be spread. A further

reduction in installation cost can be achieved by maintaining the

old refrigerant copper pipe work.

INCREASE CAPACITY

Cooling loads often increase subsequent to the

initial installation of the air conditioning system. The

Replacement VRV(VRVIII-Q) enables system capacity to

be increased without changing the refrigerant piping

(depending on system characteristics).

NO RESTRICTIONS ON SYSTEM HISTORY

As a result of the combined automatic charging

and refrigerant pipe cleaning function, it is possible

to ensure a clean piping network, even when a

compressor breakdown has previously occurred.

1. Keep main piping 2. Add indoor units

Example: replace a 10HP VRV with a 16HP Replacement VRV unit

10 HP 16 HP

FEATURES OF VRVIII-Q

195

1.

2.

4.50

4.00

3.50

3.00

2.50

2.00

1.50 R-22 R-407C R-410A VRVIII-Q

4.50

4.00

3.50

3.00

2.50

2.00

1.50 R-22 R-407C R-410A VRVIII-Q

2.373.003.10 3.10

3.98 4.00

R-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10PR-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10P

GC_pre2_lowres.pdf 195 30/11/2011 12:31:30

Page 198: DAIKIN General Catalogue 2012

196

Heat recoveryOutdoor system

System Outdoor unit module 1 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ212P

Outdoor unit module 2 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ180P RQEQ212P

Outdoor unit module 3 RQEQ180P RQEQ212P RQEQ180P RQEQ212P

Outdoor unit module 4 RQEQ212P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit module

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Power supply Phase/Frequency/Voltage Hz/V

› Cost effective and fast upgrade for R-22 systems as only the outdoor unit needs to be replaced, meaning no work has to be carried out inside your building

› Automatic cleaning of refrigerant piping ensures a clean piping network, even when a compressor breakdown has occurred

› No limitations on system history thanks to the combined refrigerant pipe cleaning and automatic charging function

› Efficiency gains of more than 40% can be realized, thanks to technological developments in heat pump technology and the more efficient R-410A refrigerant

› Possibility to add indoor units and increase capacity without changing the refrigerant piping

› Less intrusive and time consuming installation compared to installing a new system, as the refrigerant piping can be maintained in most cases

› Possibility to spread the various stages of repclacement thanks to the modular design of the VRV system

Replacement VRV

196

RQCEQ280PY1 RQCEQ360PY1 RQCEQ460PY1 RQCEQ500PY1 RQCEQ540PY1 RQCEQ636PY1 RQCEQ712PY1 RQCEQ744PY1 RQCEQ816PY1 RQCEQ848PY1

-

-

10 13 16 18 20 22 24 26 28 30

28.0 36.0 45.0 50.0 54.0 63.6 71.2 74.4 81.6 84.8

32.0 40.0 52.0 56.0 60.0 67.2 78.4 80.8 87.2 89.6

7.04 10.3 12.2 13.9 15.5 21.9 21.2 23.3 27.1 29.2

8.00 10.7 13.4 14.7 16.1 17.7 20.7 21.2 23.1 23.6

3.98 3.48 3.77 3.61 3.48 2.90 3.36 3.19 3.01 2.90

4.00 3.72 3.89 3.80 3.72 3.79 3.80 3.81 3.77 3.79

21 28 34 39 43 47 52 56 60 64

57 61 62 63 64 63 64 65 66

9.52 12.7 15.9 19.1

22.2 25.4 28.6 34.9

19.1 22.2 25.4 28.6

120

300

3~/50/400

30 40 50 60 70 80 90

RQEQ140P RQEQ180P RQEQ212P

1,680x635x765

175 179

54 58 60

-5~43

-20~15

3~/50/380-415

196

RQCEQ712-848P

RQCEQ-PRQYQ-P

GC_pre2_lowres.pdf 196 30/11/2011 12:31:30

Page 199: DAIKIN General Catalogue 2012

197

Heating & CoolingOutdoor unit

System Outdoor unit module 1 RQYQ140P RQYQ8P RQYQ10P RQYQ12P RQYQ14P RQYQ16P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RQYQ8P RQYQ10P RQYQ12P RQYQ10P RQYQ12P RQYQ14P RQYQ16P

Outdoor unit module 2 RQYQ10P RQYQ12P RQYQ16P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Current - 50Hz Maximum fuse amps (MFA) A

Outdoor unit

System Outdoor unit module 1 RQYQ10P RQYQ12P RQYQ10P RQYQ12P RQYQ14P RQYQ16P

Outdoor unit module 2 RQYQ10P RQYQ12P RQYQ16P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position)

Current - 50Hz Maximum fuse amps (MFA) A

197

RQYQ140P RQYQ8P RQYQ10P RQYQ12P RQYQ14P RQYQ16P

5 8 10 12 14 16

14.0 22.4 28.0 33.5 40.0 45.0

16.0 25.0 31.5 37.5 45.0 50.0

3.36 5.24 7.64 10.10 11.6 13.6

3.91 6.42 8.59 10.20 12.2 13.6

4.17 4.27 3.66 3.32 3.45 3.31

4.09 3.89 3.67 3.68 3.69 3.68

10 17 21 26 30 34

1,680x635x765 1,680x930x765 1,680x1,240x765

175 230 284 381

-

54.0 57.0 58.0 60.0

-5~43

-20~15.5

9.52 12.7

15.9 19.1 22.2 28.6

150

300

3~/50/380-415

15 25 35

RQYQ18PY1 RQYQ20PY1 RQYQ22PY1 RQYQ24PY1 RQYQ26PY1 RQYQ28PY1 RQYQ30PY1 RQYQ32PY1

18 20 22 24 26 28 30 32

50.4 55.9 61.5 67.0 73.0 78.5 85.0 90.0

56.5 62.5 69.0 75.0 81.5 87.5 95.0 100

12.9 15.4 17.8 20.2 21.3 23.7 25.2 27.2

15.1 16.7 18.8 20.4 22.2 23.8 25.8 27.2

3.91 3.63 3.46 3.32 3.43 3.31 3.37 3.31

3.74 3.67 3.68 3.67 3.68

39 43 47 52 56 60 64

61 62 63

15.9 19.1

28.6 34.9

150

300

45 50 60 70

RQYQ34PY1 RQYQ36PY1 RQYQ38PY1 RQYQ40PY1 RQYQ42PY1 RQYQ44PY1 RQYQ46PY1 RQYQ48PY1

34 36 38 40 42 44 46 48

96.0 101 107 112 118 124 130 135

108 113 119 125 132 138 145 150

26.9 28.9 31.4 33.8 34.9 35.3 38.8 40.8

29.4 30.8 32.4 34.0 35.8 36.0 39.4 40.8

3.57 3.49 3.41 3.31 3.38 3.51 3.35 3.31

3.67 3.68 3.69 3.83 3.68

64

64 65

19.1

34.9 41.3

150

300

90 100 110

197

GC_pre2_lowres.pdf 197 30/11/2011 12:31:31

Page 200: DAIKIN General Catalogue 2012

198

› Extensive range of outdoor units: from 8 to 30HP (9 configurations in total) › Simultaneous cooling and heating operation from one system › ‘High sensible mode’: allows the VRV system to work with

increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort

› Up to 36 indoor units can be connected to 1 refrigerant circuit › Heat recovery systems offer the highest comfort, including individual

change-over of each BS box without disruption of other BS boxes › Wide range of indoor units: 14 different models › Compact design (stacked configuration possible) › Flexible piping design: piping length after first branch: up to 90m,

maximum piping length 120m, total piping length: 300m › Operation range (inlet water temperature): 10°C to 45°C › Connectable to current Daikin control systems: DS-net, Intelligent

Touch Controller, Intelligent Manager, BACnet Gateway, DMS-iF

VRVIII water cooled, standard series

Heat recovery operation

198198

RWEYQ10P

RWEYQ-P

GC_pre2_lowres.pdf 198 30/11/2011 12:31:31

Page 201: DAIKIN General Catalogue 2012

Outdoor unit

System Outdoor unit module 1 RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P

Outdoor unit module 2 RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P

Outdoor unit module 3 RWEYQ8P RWEYQ10P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Sound pressure level Cooling Nom. dBA

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

199

Heat recoveryHeating & CoolingOutdoor unit

System Outdoor unit module 1 RWEYQ8P RWEYQ10P

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Inlet water temperature

Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Water Inlet/Outlet PT1 1/4B internal thread/PT1 1/4B internal thread

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P

-

16 18 20 24 26 28 30

44.8 49.1 53.4 67.2 71.5 75.8 80.1

50.0 56.5 63.0 75.0 81.5 88.0 94.5

9.10 10.6 12.1 13.7 15.1 16.6 18.1

8.48 10.3 12.1 12.7 14.5 16.3 18.2

4.92 4.63 4.41 4.91 4.74 4.57 4.43

5.87 5.48 5.21 5.91 5.62 5.40 5.19

34 36

53 54 55 56

12.7 15.9 19.1

28.6 (1) 34.9 (1)

22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3)

120

300

3~/50/380-415

35 45

199

RWEYQ8P RWEYQ10P

8 10

22.4 26.7

25.0 31.5

4.55 6.03

4.24 6.05

4.89 4.14

5.81 5.08

17 21

1,000x780x550

149 150

-

50 51

10~45

10~45

9.52

19.1 (1) 22.2 (1)

15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3)

120

300

3~/50/380-415

25

199

GC_pre2_lowres.pdf 199 30/11/2011 12:31:31

Page 202: DAIKIN General Catalogue 2012

200

Heat recoveryHeating & CoolingOutdoor unit

System Outdoor unit module 1 RWEYQ8PY1R RWEYQ10PY1R

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

EER

COP

Maximum number of connectable indoor units

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Operation range Inlet water temperature

Cooling Min.~Max. °CDB

Heating Min.~Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Discharge gas OD mm

Water Inlet/Outlet PT1 1/4B internal thread/PT1 1/4B internal thread

Piping length OU - IU Max. m

Total piping length System Actual m

Level difference OU - IU m 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position)

Power supply Phase/Frequency/Voltage Hz/V

Current - 50Hz Maximum fuse amps (MFA) A

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

› Reduced CO2 emmisions thanks to the use of geothermal

energy as a renewable energy source › No need for an external heating or cooling source › Extended operation range (inlet water

temperature) down to -10°C in heating › High heating efficiency at low water entering temperatures (eg.

3.44 COP at -10°C entering water temperature for an 8HP unit) › Suitable for multi-storey and large buildings because of

the hardly unlimited possibilities of water piping › Simultaneous cooling and heating operation from one system › ‘High sensible mode’: allows the VRV® system to work with

increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort

› 2-stage heat recovery: first stage between indoor units, second stage between outdoor units thanks to the storage of energy in the water circuit

› Heat recovery systems offer the highest comfort, including individual change-over of each BS box without disruption of other BS boxes

› Wide range of indoor units: 14 different models › Compact design (stacked configuration possible) › Connectable to current Daikin control systems: DS-net, Intelligent

Touch Controller, Intelligent Manager, BACnet Gateway, DMS-iF

VRV®III water cooled, geothermal series

Heat pump operation

200

RWEYQ8PR RWEYQ10PR

8 10

22.4 26.1

25.0 31.5

4.58 6.30

4.30 6.20

4.89 4.14

5.81 5.08

17 21

1,000x780x550

149 150

-

50 51

6~45

-10~45

9.52

19.1 (1) 22.2 (1)

15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3)

120

300

3~/50/380-415

25

200

RWEYQ10PR

RWEYQ-PR

GC_pre2_lowres.pdf 200 30/11/2011 12:31:31

Page 203: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 201 30/11/2011 12:31:32

Page 204: DAIKIN General Catalogue 2012

��������

202

We care icons Comfort Air flow

Ce

ilin

g m

ou

nte

d c

asse

tte

FXFQ-P9 � � � � � � � � �

FXZQ-M9 � � � � � � � �

FXCQ-M8 � � � � � � �

FXKQ-MA � � � � � � �

Co

nce

ale

d c

eili

ng

un

it

FXDQ-M9 � � � �

FXDQ-P7 � � � � �

FXSQ-P � � � � �

FXMQ-P7 � � � �

FXMQ-MA � � � �

Wall

mou

nted

uni

t

FXAQ-P � � � � � �

Ce

ilin

g s

usp

en

de

d u

nit

FXHQ-MA � � � �

FXUQ-MA � � � � � �

Flo

or

stan

din

g u

nit FXNQ-P � � � �

FXLQ-P � � � �

Benefits overview VRV® indoor

GC_pre2_lowres.pdf 202 30/11/2011 12:31:32

Page 205: DAIKIN General Catalogue 2012

203

Humidity control Air treatement Remote control & timer Other functions

2 � � � � � � � � � Standard

2 � � � � � � � � � Standard

2 � � � � � � � � Standard

2 � � � � � � � � Standard

2 � � � � � � � � �

3 � � � � � � � � � Standard

3 � � � � � � � � � Standard

3 � � � � � � � � � Standard

2 � � � � � � � � Optional

2 � � � � � � � � � Optional

2 � � � � � � � � Optional

2 � � � � � � � � Standard

3 � � � � � � � � �

3 � � � � � � � �

GC_pre2_lowres.pdf 203 30/11/2011 12:31:32

Page 206: DAIKIN General Catalogue 2012

204

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYCQ140CW1 / BYCQ140CW1W / BYCQ140CGW1

Colour Pure White(RAL 9010)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate - 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› 360° air discharge ensures uniform air flow and temperature distribution › Modern style decoration panel is available in 3 different variations:

» pure white (RAL9010) auto cleaning panel, » pure white (RAL9010) standard panel with grey louvers » pure white (RAL9010) standard panel with white louvers

› Daikin introduces first auto cleaning cassette to European market1

› Higher efficiency and comfort thanks to daily auto cleaning of the filter › Lower maintenance costs thanks to auto cleaning function › Easy dust removal with vacuum cleaner without opening the unit › Fresh air intake: up to 20 % › Comfortable horizontal air discharge ensures draughtfree

operation and prevents ceiling soiling › 23 different air flow patterns possible

› Low installation height: 214mm for class 20-63 › Standard drain pump with 850mm lift

850 mm

› Allows multi tenant applications (option PCB required) 1 Only for auto cleaning panel BYCQ140CG

Round flow cassette

204

FXFQ20P9 FXFQ25P9 FXFQ32P9 FXFQ40P9 FXFQ50P9 FXFQ63P9 FXFQ80P9 FXFQ100P9 FXFQ125P9

2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0

0.053 0.063 0.083 0.095 0.120 0.173 0.258

0.045 0.055 0.067 0.114 0.108 0.176 0.246

204x840x840 246x840x840 288x840x840

20 21 24 26

50x950x950 / 50x950x950 / 130x950x950

5.5 / 5.5 / 11.5

12.5/9.0 13.5/9.0 15.5/10.0 16.5/11.0 23.5/14.5 26.5/17.0 33.0/20.0

12.5/9.0 13.5/9.0 15.0/9.5 17.5/12.0 23.5/14.5 28.0/17.5 33.0/20.0

49 50 51 52 55 58 61

31/28 32/28 33/28 34/29 38/32 41/33 44/34

31/28 32/28 33/28 36/30 38/32 42/34 44/34

6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

1~/50/60/220-240/220

16

204

FXFQ-P9

BRC1E52A BRC7F532FXFQ20-63P9

GC_pre2_lowres.pdf 204 30/11/2011 12:31:33

Page 207: DAIKIN General Catalogue 2012

205

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYFQ60BW1 BYFQ60B7W1

Colour White

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling High/Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Comfortable vertical air discharge ensures draughtfree operation and prevents ceiling soiling

› Compact casing (575mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

› 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc.

› Whisper quiet operation: down to 25dBA sound pressure level › Fresh air intake for healthy living › Since the flaps can move to a 0 degree position, virtually no draught can

be experienced

› Possibility to shut 1 or 2 flaps for easy installation in corners

13

1

1 1 1 13 3 3

3

3

4

4 4 4 4

42

2 2 2 2

2

2-way blow

3-way blow

› Easy maintenance: switch box can be reached by simply removing the suction grille

› Standard drain pump with 750mm lift › Allows multi tenant applications (option PCB required)

4-way blow ceiling mounted cassette

205

FXZQ15M9 FXZQ20M9 FXZQ25M9 FXZQ32M9 FXZQ40M9 FXZQ50M9

1.7 2.2 2.8 3.6 4.5 5.6

1.9 2.5 3.2 4.0 5.0 6.3

0.073 0.073 0.076 0.089 0.115

0.064 0.064 0.068 0.080 0.107

286x575x575

18

55x700x700

2.7

8.1/7 9.0/7.0 9.5/7.5 11.0/8.0 14.0/10.0

-/46 -/47 -/49 -/53 -/58

29/25 30/25 32/26 36/28 41/33

6.35/12.7/VP20 (I.D. 20/O.D. 26) 6.35/12.70/26

1~/50/220-240

15

205

FXZQ-M9 BRC1E52A BRC7E530

FXZQ-M9

GC_pre2_lowres.pdf 205 30/11/2011 12:31:33

Page 208: DAIKIN General Catalogue 2012

206

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBC32GJW1 BYBC50GJW1 BYBC63GJW1 BYBC125GJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate - 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Auto swing function ensures efficient air and temperature distribution and prevents ceiling soiling

› Easy to install: depth of all units is 600mm › Maintenance operations can be performed by removing the front panel › Standard drain pump with 600mm lift

�����

2-way blow ceiling mounted cassette

206

FXCQ20M8 FXCQ25M8 FXCQ32M8 FXCQ40M8 FXCQ50M8 FXCQ63M8 FXCQ80M8 FXCQ125M8

2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0

2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0

0.077 0.092 0.130 0.161 0.209 0.256

0.044 0.059 0.097 0.126 0.176 0.223

305x780x600 305x995x600 305x1,180x600 305x1,670x600

350

26 31 32 35 47 48

53x1,030x680 53x1,245x680 53x1,430x680 53x1,920x680

8 8.5 9.5 12

7/5 9/6.5 12/9 16.5/13 26/21 33/25

7/5 9/6.5 12/9 16.5/13 26/21 33/25

45 50 52 54 60

33/28 35/29 35.0/29.0 35.5/30.5 38/33 40/35 45/39

33/28 35/29 35.0/29.0 35.5/30.5 38/33 40/35 45/39

6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.90/VP25 (O.D. 32 / I.D. 25)

1~/50/230

16

206

FXCQ20-32M8 BRC1E52A BRC7C62

FXCQ-M8

GC_pre2_lowres.pdf 206 30/11/2011 12:31:33

Page 209: DAIKIN General Catalogue 2012

207

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Decoration panel Model BYK45FJW1 BYK71FJW1

Colour White

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Compact dimensions, can easily be mounted in a narrow ceiling void (only 220mm ceiling space required, 195 with panel spacer, available as accessory)

› Comfortable horizontal auto swing ensures draughtfree operation and prevents ceiling soiling

› Optimum air flow conditions are created by either downward air discharge or frontal air discharge (via optional grille) or a combination of both

��!"!�#$�$�&�'�#(�

)#�"����$�&�'�#(�

���&�$�$���#����"���"��

�����"����"�

› Standard drain pump with 500mm lift

Ceiling mounted corner cassette

207

FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA

2.8 3.6 4.5 7.10

3.2 4.0 5.0 8.00

0.066 0.076 0.105

0.046 0.056 0.085

215x1,110x710 215x1,310x710

31 34

70x1,240x800 70x1,440x800

8.5 9.5

11/9 13/10 18/15

-

38.0/33.0 40.0/34.0 42.0/37.0

6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

1~/50/60/220-240/220

15

207

FXKQ-MA BRC1E52A BRC4C61

FXKQ-MA

GC_pre2_lowres.pdf 207 30/11/2011 12:31:33

Page 210: DAIKIN General Catalogue 2012

208

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Fan-Air flow rate - 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Designed for hotel bedrooms › Compact dimensions (230mm high & 652mm deep),

can easily be mounted in a ceiling void › Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible › Standard air filter removes airborne dust particles

to ensure a steady supply of clean air › The air suction direction can be altered from rear to bottom suction › For easy mounting, the drain pan can be

located to the left or right of the unit › Allows multi tenant applications (option PCB required)

Small concealed ceiling unit

208

FXDQ20M9 FXDQ25M9

2.2 2.8

2.5 3.2

0.050

0.050

230x502x652

250

17

6.7/5.2 7.4/5.8

6.7/5.2 7.4/5.8

50

37/32

37/32

6.35/12.7/I.D. 21.6, O.D. 27.2

1~/50/230

16

208

FXDQ-M9 BRC1E52A BRC4C62

FXDQ-M9

GC_pre2_lowres.pdf 208 30/11/2011 12:31:33

Page 211: DAIKIN General Catalogue 2012

209

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling Super high/High/Nom./Low m³/min

Fan-External static pressure - 50Hz High/Nom. Pa

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Nom./Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Compact dimensions, can easily be mounted in a ceiling void of only 240mm

200mm

› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

› 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc.

› Medium external static pressure facilitates unit use with flexible ducts of varying lengths

› Standard air filter removes airborne dust particles to ensure a steady supply of clean air

› Standard drain pump with 750mm lift

������

› Allows multi tenant applications (option PCB required)

Slim concealed ceiling unit

209

FXDQ15P7 FXDQ20P7 FXDQ25P7 FXDQ32P7 FXDQ40P7 FXDQ50P7 FXDQ63P7

1.7 2.2 2.8 3.6 4.5 5.6 7.1

1.9 2.5 3.2 4.0 5.0 6.3 8.0

0.086 0.089 0.160 0.165 0.181

0.067 0.070 0.147 0.152 0.168

200x700x620 200x900x620 200x1,100x620

240

23 27 28 31

7.5/7.0/-/6.4 8.0/7.2/-/6.4 10.5/9.5/-/8.5 12.5/11.0/-/10.0 16.5/14.5/-/13.0

30/10 44/15

50 51 52 53 54

32/31/29 33/31/29 34/32/30 35/33/31 36/34/32

6.35/12.7/VP20 (I.D. 20/O.D. 26) 9.52/15.9/VP20 (I.D. 20/O.D. 26)

/50/60/220-240/220 1~/50/60/220-240/220

16 15

209

FXDQ20-32P7 BRC1E52A BRC4C65

FXDQ-P7

GC_pre2_lowres.pdf 209 30/11/2011 12:31:34

Page 212: DAIKIN General Catalogue 2012

210

FXSQ-Medium static pressure

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate

- 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Fan-External static pressure - 50Hz High/Nom. Pa

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Easy installation thanks to automatic air flow adjustment towards nominal air flow rate › Using a DC fan shows a 20% reduction in power consumption compared to the previous series › Improved comfort thanks to 3-step air flow control › Up to 140Pa external static pressure (ESP) facilitates using flexible ducts of variying lengths: ideal for shops and medium size offices (FXSQ) › Up to 200Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas (FXMQ) › Possibility to change ESP via wired remote control allows optimisation of the supply air volume › Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible › The use of an integrated inverter control ensures maximum comfort and efficiency. › The air suction direction can be altered from rear to bottom suction › Standard air filter removes airborne dust particles to ensure a steady supply of clean air › Standard built-in drain pump increases reliability of the drain system › Allows multi tenant applications (option PCB required)

Concealed ceiling unit with inverter driven fan

+/- 10%

Easy installation thanks to automatic air flow adjustment towards nominal air flow: Installation made easier

Reduced installation time

› After installation, it is possible that the actual duct

resistance is lower than expected at time of designing.

As a consequence the air flow will be too high.

› With the automatic air flow adjustment function the unit can

adapt its fan speed to a lower curve, so the air flow decreases.

› The air flow will always be within 10% of the rated air flow because of the

amount of possible fan curves (more than 8 fan curves available per model).

› Alternatively the installer can manually select a fan

curve with the wired remote control.

Ext

ern

al s

tati

c p

ress

ure

(P

a)

Air flow (m³/min)

Fan characteristic curveActual duct resistance curveDuct resistance curve at the time of designing

Rated air flowAirflow without air flow automatic adjustmentActual airflow

210

FXSQ20P FXSQ25P FXSQ32P FXSQ40P FXSQ50P FXSQ63P FXSQ80P FXSQ100P FXSQ125P FXSQ140P

2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0

2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 18.0

0.041 0.044 0.097 0.074 0.118 0.117 0.185 0.261

0.029 0.032 0.085 0.062 0.106 0.105 0.173 0.249

300x550x700 300x700x700 300x1,000x700 300x1,400x700

350

23 26 35 46 47

55x650x500 55x800x500 55x1,100x500 55x1,500x500

3.0 3.5 4.5 6.5

9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32

9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32

70/30 100/30 100/40 120/40 120/50 140/50

55 56 63 59 63 61 66 67

32/26 33/27 37/29 37/30 38/32 40/33 42/34

32/26 33/27 37/29 37/30 38/32 40/33 42/34

6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

1~/50/60/220-240/220

16

210

FXSQ20-32P BRC1E52A BRC4C66

FXSQ-P / FXMQ-P7

FXMQ20-32P7

GC_pre2_lowres.pdf 210 30/11/2011 12:31:34

Page 213: DAIKIN General Catalogue 2012

211

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Unpainted

Dimensions Unit HeightxWidthxDepth mm

Required ceiling void > mm

Weight Unit kg

Decoration panel Model BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1

Colour White (10Y9/0.5)

Dimensions HeightxWidthxDepth mm

Weight kg

Fan-Air flow rate

- 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Fan-External static pressure - 50Hz High/Nom. Pa

Sound power level Cooling High/Nom. dBA

Sound pressure level

Cooling High/Nom./Low dBA

Heating High/Nom./Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

211

FXMQ20P7 FXMQ25P7 FXMQ32P7 FXMQ40P7 FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7

2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0

0.049 0.053 0.151 0.110 0.120 0.171 0.176 0.241

0.037 0.041 0.139 0.098 0.108 0.159 0.164 0.229

300x550x700 300x700x700 300x1,000x700 300x1,400x700

350

23 26 35 46

55x650x500 55x800x500 55x1,100x500 55x1,500x500

3.0 3.5 4.5 6.5

9/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28

9.0/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28

100/50 160/100 200/100

56/- 57/- 65/- 61/- 64/- 67/- 65/- 70/-

33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40

33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40

6.35/12.7/VP25 (I.D. 25/O.D. 32) 9.52/15.9/VP25 (I.D. 25/O.D. 32)

1~/50/60/220-240/220

16

211

FXMQ-P7 - High stactic pressure

FXMQ-P7

GC_pre2_lowres.pdf 211 30/11/2011 12:31:34

Page 214: DAIKIN General Catalogue 2012

212

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Fan-External static pressure - 50Hz High/Nom. Pa

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Up to 270Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas

› Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

› Up to 31.5kW in heating mode

Large concealed ceiling unit

212

FXMQ200MA FXMQ250MA

22.4 28.0

25.0 31.5

1.294 1.465

1.294 1.465

470x1,380x1,100

137

58/50 72/62

221/132 270/191

-

48/45

9.52/19.1/PS1B 9.52/22.2/PS1B

1~/50/60/220-240/220

15

212

FXMQ200-250MA BRC1E52A BRC4CC66

FXMQ-MA

GC_pre2_lowres.pdf 212 30/11/2011 12:31:34

Page 215: DAIKIN General Catalogue 2012

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour White (3.0Y8.5/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP13 (I.D. 13/O.D. 18)

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

*Note: grey cells contain preliminary data

› Modern style decoration panel in white (RAL9010) › Vertical auto swing moves the discharge flaps up and down for

efficient air and temperature distribution throughout the room › 5 different discharge angles can be programmed via the remote control › 15 class unit especially developed for small or well-insulated

rooms, such as hotel bedrooms, small offices, etc. › Both horizontal flaps and front panel can easily be removed and washed › Maintenance operations can be performed from the front of the unit › Can be installed in both new and existing buildings › Allows multi tenant applications (option PCB required)

Wall mounted unit

NEW

NEW

*FXAQ15P FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P

1.7 2.2 2.8 3.6 4.5 5.6 7.1

1.9 2.5 3.2 4.0 5.0 6.3 8.0

- 0.019 0.028 0.030 0.020 0.033 0.050

- 0.029 0.034 0.035 0.020 0.039 0.060

-

290x795x238 290x795x238 290x1,050x238

- 11 14

7/4.5 7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14

- -

33/29 35.0/29.0 36.0/29.0 37.0/29.0 39.0/34.0 42.0/36.0 46.0/39.0

R-410A

-/-/

1~/50/220-240 1~/50/220-240

- 16

FXAQ15-32P

FXAQ-P

213

BRC1E52A BRC7E63

GC_pre2_lowres.pdf 213 30/11/2011 12:31:34

Page 216: DAIKIN General Catalogue 2012

214

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour White (10Y9/0.5)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Can be installed in both new and existing buildings › Wider air discharge thanks to Coanda effect: up to 100°

100°

› Air flow distribution for ceiling heights up to 3.8m without capacity loss › The unit can easily be mounted in corners and narrow

spaces, as it only needs 30mm lateral service space

Ceiling suspended unit

214

FXHQ32MA FXHQ63MA FXHQ100MA

3.6 7.1 11.2

4.0 8.0 12.5

0.111 0.115 0.135

0.111 0.115 0.135

195x960x680 195x1,160x680 195x1,400x680

24 28 33

12/10 17.5/14 25/19.5

-

36/31 39/34 45/37

6.35/12.7/VP20 (I.D. 20/O.D. 26) 9.52/15.9/VP20 (I.D. 20/O.D. 26)

1~/50/60/220-240/220

15

214

FXHQ32MA

FXHQ-MA

BRC1E52A BRC7E63

GC_pre2_lowres.pdf 214 30/11/2011 12:31:35

Page 217: DAIKIN General Catalogue 2012

215

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour White

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz

Cooling High/Low m³/min

Heating High/Low m³/min

Sound power level Cooling High/Nom. dBA

Sound pressure level

Cooling High/Low dBA

Heating High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

› Can be installed in both new and existing buildings › Air can be discharged in any of 4 directions › Auto swing function ensures efficient air and temperature distribution › Air can be discharged in 5 different angles between 0 and 60°

› Possibility to shut 1 or 2 flaps for easy installation in corners

› Air flow distribution for ceiling heights up to 3.5m without capacity loss › Standard drain pump with 500mm lift

4-way blow ceiling suspended unit

Indoor unit

Power input Cooling Nom. kW

Heating Nom. kW

Casing Material Galvanised steel plate

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Piping connections

Outdoor unit Liquid Type/OD mm Flare connection/9.52

Gas OD/Type

Indoor unit Liquid Type/OD mm Flare connection/9.52

Gas Type/OD mm Flare connection/15.9

Sound absorbing thermal insulation Flame and heat resistant foamed polyetherene

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

215

FXUQ71MA FXUQ100MA FXUQ125MA

8.0 11.2 14.0

9.0 12.5 14.0

0.180 0.289

0.160 0.269

165x895x895 230x895x895

25 31

19/14 29/21 32/23

19/14 29/21 32/23

56/- 59/- 60/-

40/35 43/38 44/39

40/35 43/38 44/39

9.52/15.9/I.D. 20/O.D. 26

1~/50/220-240

BEVQ71MA BEVQ100MA BEVQ125MA

0.189 0.298

0.169 0.278

100x350x225

3.0 3.5

15.9/Flare connection

1~/50/60/220-240/220

15

215

FXUQ-MA BEVQ-MA

FXUQ-MA

BRC1E52A BRC7C528

GC_pre2_lowres.pdf 215 30/11/2011 12:31:35

Page 218: DAIKIN General Catalogue 2012

216

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Ideal for installation beneath a window › Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible › Requires very little installation space › The connecting port faces downward, eliminating the need to attach

auxiliary piping

Connecting port

Refrigerant piping

› Allows multi tenant applications (option PCB required)

Concealed floor standing unit

216

FXNQ20P FXNQ25P FXNQ32P FXNQ40P FXNQ50P FXNQ63P

2.2 2.8 3.6 4.5 5.6 7.1

2.5 3.2 4.0 5.0 6.3 8.0

0.049 0.090 0.110

0.049 0.090 0.110

610x930x220 610x1,070x220 610x1,350x220

19 23 27

7/6 8/6 11/8.5 14/11 16/12

-

35/32 38/33 39/34 40/35

6.35/12.7/ 9.52/15.9/

1~/50/60/220-240/220

15

216

FXNQ20-25P BRC1E52A BRC7C62

FXNQ-P

GC_pre2_lowres.pdf 216 30/11/2011 12:31:35

Page 219: DAIKIN General Catalogue 2012

217

Indoor unit

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input - 50Hz Cooling Nom. kW

Heating Nom. kW

Casing Colour Fresh white (RAL9010) / Dark grey (RAL7011)

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz Cooling High/Low m³/min

Sound power level Cooling Nom. dBA

Sound pressure level Cooling High/Low dBA

Refrigerant Type R-410A

Piping connections Liquid/OD/Gas/OD/Drain mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

› Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011)

› Unit can be installed as free standing model by use of optional back plate › Ideal for installation beneath a window › Requires very little installation space › Wall mounted installation facilitates cleaning beneath the unit where dust

tends to accumulate

› Allows multi tenant applications (option PCB required) › Wired remote control can easily be integrated in the unit

Floor standing unit

217

FXLQ20P FXLQ25P FXLQ32P FXLQ40P FXLQ50P FXLQ63P

2.2 2.8 3.6 4.5 5.6 7.1

2.5 3.2 4.0 5.0 6.3 8.000

0.049 0.090 0.110

0.049 0.090 0.110

600x1,000x232 600x1,140x232 600x1,420x232

27 32 38

7/6 8/6 11/8.5 14/11 16/12

-

35/32 38/33 39/34 40/35

6.35/12.7/ 9.52/15.9/

1~/50/60/220-240/220

15

217

FXLQ20-25P BRC1E52A BRC7C62

FXLQ-P

GC_pre2_lowres.pdf 217 30/11/2011 12:31:35

Page 220: DAIKIN General Catalogue 2012

218

Indoor unit

Heating capacity Nom. kW

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound pressure level

Nom. dBA

Night quiet mode Level 1 dBA

Operation range Heating Ambient Min.~Max. °C

Water side Min.~Max. °C

Domestic hot water

Ambient Min.~Max. °CDB

Water side Min.~Max. °C

Refrigerant Type R-134a

Refrigerant circuit Gas side diameter mm

Liquid side diameter mm

Water circuit Piping connections diameter inch G 1” (female)

Heating water system Water volume Min.~Max. l

Power supply Phase/Frequency/Voltage Hz/V

Current Recommended fuses A

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

› Temperature control, fresh air provision, Biddle air curtains and hot water production all integrated in a single system

› Free heating provided by transferring heat from areas requiring cooling to areas requiring heating or hot water

› Uses heat pump technology to produce hot water efficiently, providing up to 17% savings compared to a gas boiler

› VRV plug-and-play as all necessary components are integrated for quick installation

› No need to design the water side: all water-side components are integrated, moreover no mixing valve is required thanks to direct leaving water temperature control

› Possibility to connect thermal solar collectors to the domestic hot water tank

› Various control possibilities with weather dependant set point or thermostat control

› The indoor unit and domestic hot water tank can be stacked to save space, or installed next to each other, if only limited height is available

› Leaving water temperature range from 25 to 80°C without electric heater › Super wide operating range for hot water production

from -20 to +43°C ambient outdoor temperature › Possible applications include bathrooms, sinks, underfloor

heating, radiators and air handling units › No gas connection needed

Heating only hydrobox for VRV

VRV heat recovery with connection to heating only

hydrobox(REYAQ10-16P)

BS-Box

BS-Box

Heating only hydrobox for VRV

Domestic hot water tank

Domestic hot water

Low temp. radiator

Air handling unit

Under floor heating

Liquid pipe

F1, F2 communication

Gas pipe

Hot water

Discharge gas pipe

VRV indoor units

218

HXHD125A

14.0

705x600x695

92

42 (1) / 43 (2)

38 (5)

-20~20 / 24 (3)

25~80

-20~43

45~75

12.7

9.52

20~200

1~/50/220-240

20

218

HXHD-A EKHTS-AC EKHWP-A

HXHD-A

25°C - 35°C

45°C - 75°C

25°C - 75°C

45°C - 75°C

GC_pre2_lowres.pdf 218 30/11/2011 12:31:35

Page 221: DAIKIN General Catalogue 2012

219

Indoor unit

Casing Colour Metallic grey

Material Galvanised steel (precoated sheet metal)

Dimensions Unit HeightxWidthxDepth mm 2,010x600x695 (Integrated on indoor unit) 2,285x600x695 (Integrated on indoor unit)

Weight Unit Empty kg

Tank Water volume l

Material Stainless steel (EN 1.4521)

Maximum water temperature °C

Heat exchanger Quantity

Tube material Duplex steel (EN 1.4162)

Face area m²

Internal coil volume l

› Stainless steel domestic hot water tank › The indoor unit and domestic hot water tank can be stacked to save space,

or installed next to each other, if only limited height is available › Available in 200 and 260 liters › Heat loss is reduced to a minimum thanks to the high quality insulation › At necessary intervals, the indoor unit can heat up the water

to 60°C to prevent the risk of bacteria growth › Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes

Domestic hot water tank

Indoor unit

Casing Colour Dust grey (RAL7037)

Material Impact resistant polypropylene

Dimensions Unit HeightxWidthxDepth mm

Weight Unit Empty kg

Tank Water volume l

Maximum water temperature °C

Heat exchanger Domestic hot water

Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Operating pressure bar

Average specifc thermal output W/K

Charging Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Average specifc thermal output W/K

Auxiliary solar heating

Tube material Stainless steel (DIN 1.4404)

Face area m²

Internal coil volume l

Average specifc thermal output W/K

› Tank designed for connection with thermal solar collectors › Available in 300 and 500 liters › Large hot water storage tank to provide domestic hot water at any time › Heat loss is reduced to a minimum thanks to the high quality insulation › Space heating support possible (500l tank only)

Domestic hot water tank

with possibility for solar connection

219

EKHTS200AC EKHTS260AC

70 78

200 260

75

1

1.56

7.5

EKHWP300A EKHWP500A

1,590x595x615 1,590x790x790

59 92

300 500

85

5.7 5.9

27.8 28.4

6

2,795 2,860

2.5 3.7

12.3 17.4

1,235 1,809

- 1.0

- 5

- 313

219

EKHTS200AC EKHTS260AC

EKHTS-AC

EKHWP300A EKHWP500A

EKHWP-A

GC_pre2_lowres.pdf 219 30/11/2011 12:31:36

Page 222: DAIKIN General Catalogue 2012

220

Indoor unit

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Volume l

Surface Outer m²

Aperture m²

Absorber m²

Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)

Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate

Glazing Single pane safety glass, transmission +/- 92%

Allowed roof angle Min.~Max. °

Operating pressure Max. bar

Stand still temperature Max. °C

Thermal performance

Zero loss collector efficiency η0 %

Heat loss coefficient a1 W/m².K

Temperature dependence of the heat loss coefficient a2 W/m².K²

Thermal capacity kJ/K

Incident angle modifier AM at 50°

Installed position Vertical Horizontal

› Horizontal and vertical solar collector for domestic hot water production › Solar panels can produce up to 70% of the energy needed

for hot water production – a major cost saving › High efficiency collectors transfer all the short-wave solar

radiation into heat as a result of their highly selective coating › Easy to install on roof tiles › The solar collectors are charged with water only when needed

for heating – avoiding the need for ‘anti-freeze’ protection

Solar collector

Indoor unit

Mounting On side of tank

Dimensions Unit HeightxWidthxDepth mm

Thermal performance Zero loss collector efficiency η0 %

Control Type Digital temperature difference controller with plain text display

Power consumption W

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return flow sensor PTC

Feed temperature and flow sensor Voltage signal (3.5V DC)

Power supply Voltage V

› Save energy and reduce CO2 emissions with a solar

system for domestic hot water production › Pump station connectable to unpressurised solar system › Pump station and control provide the transfer of

solar heat to the domestic hot water tank

Pump station

220

EKSV26P EKSH26P

2,000x1,300x85 1,300x2,000x85

43

1.7 2.1

2.601

2.364

2.354

15~80

6

200

78.7

4.270

0.0070

6.5

0.94

EKSRPS3

815x230x142

-

2

230

220

EKSV-P

EKSV/H-P

EKSH-P

EKSRPS

EKSRPS

GC_pre2_lowres.pdf 220 30/11/2011 12:31:36

Page 223: DAIKIN General Catalogue 2012

221

Xpress is a software tool that allows creating on the spot

quotations for a Daikin VRV or CMSQ System. It provides a

result in 7 steps to enable a professional budget quotation:

1. Select indoor units

2. Connect outdoor units to indoor units

3. Automatic generation of piping diagram with joints

4. Automatic generation of wiring diagram

5. Select possible centralised control systems

6. Visualise result in MS Word, MS Excel and AutoCAD

7. Save project

The VRV Pro selection programme is a true VRV design tool. The

programme enables VRV air conditioning systems to be engineered

in

a precise and economical way, taking into account the realtime

thermal properties of any building. By calculating annual energy

consumptions, it gives the designer the possibility to make

accurate selections and get competitive quotations for each

project. Moreover, it ensures optimum operating cycles and

maximum energy efficiency.

For more information, please contact your affiliate/distibutor.

Windows95, Windows98, WindowsNT, Windows2000, WindowsXP and Windows Vista are registered trademarks of Microsoft corporation.

Powerful selection programmes

VRV Pro, Design tool

Xpress, Quick Quotation tool

Powerful selection programmes

GC_pre2_lowres.pdf 221 30/11/2011 12:31:36

Page 224: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 222 30/11/2011 12:31:36

Page 225: DAIKIN General Catalogue 2012

VENTILATION & BIDDLE AIR CURTAINS

VENTILATION 224

Heat reclaim ventilation 224

VAM-FA 224

VKM-GA(M) 225

Outdoor air processing unit 226

FXMQ-MF 226

Air handling applications 227

VRV Heat Recovery/VRV Heat Pump 227

ERQ 228

BIDDLE AIR CURTAINS 232

Biddle comfort air curtain for VRV 232

Biddle standard air curtain for ERQ 233

For more information on Options & Accessories, please refer to page 356 of this catalogue.

With the advent of new building regulations, greater awareness of increasing energy costs

and a responsibility towards environmental issues, modern commercial spaces are insulated

better than ever. Double glazing, thicker roof insulation and draught excluders of course, help

considerably towards reducing heating/cooling demand and burdens on the environment.

The down-side however, is that these same commercial spaces have now become, in effect,

sealed boxes with little or no replenishment of the air. Daikin offers a variety of solutions for

the provision of fresh air ventilation to offices, hotels, stores and other commercial outlets –

each one complementary to and as flexible as VRV systems themselves.

223

GC_pre2_lowres.pdf 223 30/11/2011 12:31:37

Page 226: DAIKIN General Catalogue 2012

224

› Energy saving ventilation by recovery of indoor unit heat/cold › Ideal solution for shops, restaurants or offices requiring

maximum floor space for furniture, decorations and fittings › Free cooling when outdoor temperature is below

indoor temperature (eg. during night time) › Can be used as stand alone unit or integrated in the VRV® system › Wide range of units: air flow rate from 150 up to 2,000 m³/h › Specially developed heat exchange element

with High Efficiency Paper (HEP) › No drain piping needed › Can operate in over- and under pressure

Heat reclaim ventilation

Total heat exchanged

foul air

Clean outdoor air

Total heat

exchanged

clean airFoul indoor air

Ventilation

Power input - 50Hz Heat exchange mode Nom. Ultra high kW

Bypass mode Nom. Ultra high kW

Temperature exchange efficieny - 50Hz Ultra high %

Enthalpy exchange efficieny - 50Hz

Cooling Ultra high %

Heating Ultra high %

Operation mode Heat exchange mode / Bypass mode / Fresh-up mode

Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange

Heat exchange element Specially processed non-flammable paper

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz

Heat exchange mode Ultra high m³/h

Bypass mode Ultra high m³/h

Fan-External static pressure - 50Hz Ultra high Pa

Sound pressure level - 50Hz

Heat exchange mode Ultra high dBA

Bypass mode Ultra high dBA

Operation range Min. °CDB

Max. °CDB

Relative humidity %

Connection duct diameter mm

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

224

VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA

0.116 0.141 0.194 0.212 0.380 0.451 0.469 0.864 0.953

0.116 0.141 0.194 0.212 0.380 0.451 0.469 0.864 0.953

74 72 75 74 75

58 61 58 60 61

64 65 62 63 65 66

285x776x525 301x828x816 364x1,004x868 364x1,004x1,156 726x1,514x868 726x1,514x1,156

24 33 48 61 132 158

150 250 350 500 650 800 1,000 1,500 2,000

150 250 350 500 650 800 1,000 1,500 2,000

69 64 98 93 137 157 137

27 / 28.5 28 / 29 32 / 34 33 / 34.5 34.5 / 35.5 36 / 37 36 / 37 39.5 / 41.5 40 / 42.5

27 / 28.5 28 / 29 32 / 34 33.5 / 34.5 34.5 / 35.5 36 / 37 36 / 37 40.5 / 41.5 40 / 42.5

-15

50

80% or less

100 150 200 250 350

1~/50/60/220-240/220

15

224

VAM-FA

GC_pre2_lowres.pdf 224 30/11/2011 12:31:37

Page 227: DAIKIN General Catalogue 2012

225

› Creates a high quality indoor environment by pre conditioning incoming fresh air

› Humidification of incoming air maintains a comfortable indoor humidity level, even during heating

› Energy saving ventilation by recovery of indoor unit heat/cold › Ideal solution for shops, restaurants or offices requiring

maximum floor space for furniture, decorations and fittings › Free cooling when outdoor temperature is below

indoor temperature (eg. during night time) › Wide range of units: air flow rate from 150 up to 2,000 m³/h › Specially developed heat exchange element

with High Efficiency Paper (HEP) › No drain piping needed › Can operate in over- and under pressure

Heat reclaim ventilation, humidification

and air processing

Ventilation & DX coil

Power input - 50Hz Heat exchange mode Nom. Ultra high kW

Bypass mode Nom. Ultra high kW

Fresh air

conditioning load

Cooling kW

Heating kW

Temperature exchange efficiency - 50Hz Ultra high %

Enthalpy exchange efficiency - 50Hz Cooling Ultra high %

Operation mode Heat exchange mode / Bypass mode / Fresh-up mode

Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange

Heat exchange element Specially processed non-flammable paper

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz

Heat exchange mode Ultra high m³/h

Bypass mode Ultra high m³/h

Fan-External static pressure - 50Hz Ultra high Pa

Sound pressure level - 50Hz

Heat exchange mode Ultra high dBA

Bypass mode Ultra high dBA

Operation range Around unit °CDB

Supply air °CDB

Return air °CDB

Connection duct diameter mm

Piping connections

Liquid OD mm

Gas OD mm

Drain PT3/4 external thread

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

Ventilation, DX coil & humidification

Power input - 50Hz Heat exchange mode Nom. Ultra high kW

Bypass mode Nom. Ultra high kW

Fresh air conditioning load

Cooling kW

Heating kW

Temperature exchange efficiency - 50Hz Ultra high %

Enthalpy exchange efficiency - 50Hz Cooling Ultra high %

Operation mode Heat exchange mode / Bypass mode / Fresh-up mode

Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange

Heat exchange element Specially processed non-flammable paper

Humidifier System Natural evaporating type

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air flow rate - 50Hz

Heat exchange mode Ultra high m³/h

Bypass mode Ultra high m³/h

Fan-External static pressure - 50Hz Ultra high Pa

Sound pressure level - 50Hz

Heat exchange mode Ultra high dBA

Bypass mode Ultra high dBA

Operation range Around unit °CDB

Supply air °CDB

Return air °CDB

Connection duct diameter mm

Piping

connections

Liquid OD mm

Gas OD mm

Water supply mm

Drain PT3/4 external thread

Power supply Phase/Frequency/Voltage Hz/V

Maximum Fuse Amps (MFA) A

225

VKM50GA VKM80GA VKM100GA

0.560 0.620 0.670

0.560 0.620 0.670

4.71 7.46 9.12

5.58 8.79 10.69

76 78 74

64 66 62

387x1,764x832 387x1,764x1,214

96 109 114

500 750 950

500 750 950

180 170 150

38 / 38.5 / 39 40 / 41 / 41.5 40 / 40.5 / 41

38 / 38.5 / 39 40 / 41 / 41.5 40 / 40.5 / 41

0°C~40°CDB, 80% RH or less

-15°C~40°CDB, 80% RH or less

0°C~40°CDB, 80% RH or less

200 250

6.35

12.7

1~/50/220-240

15

VKM50GAM VKM80GAM VKM100GAM

0.560 0.620 0.670

0.560 0.620 0.670

4.71 7.46 9.12

5.58 8.79 10.69

76 78 74

64 66 62

387x1,764x832 387x1,764x1,214

102 120 125

500 750 950

500 750 950

160 140 110

37 / 37.5 / 38 38.5 / 39 / 40 39 / 39.5 / 40

37 / 37.5 / 38 38.5 / 39 / 40 39 / 39.5 / 40

0°C~40°CDB, 80% RH or less

-15°C~40°CDB, 80% RH or less

0°C~40°CDB, 80% RH or less

200 250

6.35

12.7

6.4

1~/50/220-240

15

225

VKM-GA(M)

VKM80-100GAM

GC_pre2_lowres.pdf 225 30/11/2011 12:31:37

Page 228: DAIKIN General Catalogue 2012

226

› 100% fresh air intake possible › Ideal solution for shops, restaurants or offices requiring

maximum floor space for furniture, decorations and fittings › Operation range: -5°C to 43°C › Up to 225Pa external static pressure allows extensive ductwork

runs and flexible application: ideal for use in large areas › Drain pump kit available as accessory

Outdoor air processing unit, ventilation

and air processing

Ventilation & air processing FXMQ125MF FXMQ200MF FXMQ250MF

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power Input (50Hz)

Cooling Nominal kW

Heating Nominal kW

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Air Flow Rate Cooling m3/min

Heating m3/min

External Static Pressure Standard Pa

Refrigerant Type R-410A

Sound Power Cooling Nominal dBA

Sound Pressure Cooling Nominal (220V) dBA

Piping

connections

Liquid OD mm

Gas OD mm

Drain PS1B

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

226

14.0 22.4 28.0

8.9 13.9 17.4

0.359 0.548 0.638

0.359 0.548 0.638

470x744x1,100 470x1,380x1,100

86 123

18 28 35

-

185 225 205

-

42 47

9.52

15.9 19.1 22.2

226

FXMQ-MF

FXMQ200-250MF

GC_pre2_lowres.pdf 226 30/11/2011 12:31:37

Page 229: DAIKIN General Catalogue 2012

A R-410A inverter condensing units range for multi application with air handling units.

› Inverter controlled units › Large capacity range (from 5 to 54HP) › Heat recovery, heat pump › R-410A › Control of room temperature via Daikin control › Large range of expansion valve kits available › BRC1D52 is used to set the set point temperature (connected to the EKEQMCB). › Connectable to all VRV heat recovery and heat pump systems*

EKEXV-kit

gas pipe

liquid pipe

F1-F2

other communication

EKEXV class

Allowed heat exchanger capacity (kW)

Cooling (Evaporation temperature 6°C) Heating (Condensing temperature 46°C)

Minimum Standard Maximum Minimum Standard Maximum

50

63

80

100

125

140

200

250

VRV� air handling applications

5.0 5.6 6.2 5.6 6.3 7.0

6.3 7.1 7.8 7.1 8.0 8.8

7.9 9.0 9.9 8.9 10.0 11.1

10.0 11.2 12.3 11.2 12.5 13.8

12.4 14.0 15.4 13.9 16.0 17.3

15.5 16.0 17.6 17.4 18.0 19.8

17.7 22.4 24.6 19.9 25.0 27.7

24.7 28.0 30.8 27.8 31.5 34.7

227

EKEQMCB

GC_pre2_lowres.pdf 227 30/11/2011 12:31:38

Page 230: DAIKIN General Catalogue 2012

A range of R-410A inverter condensing units for pair application with air handling units.

› Inverter controlled units › Large capacity range (from 100 to 250 class) › Heat pump › R-410A › Flexible control possibilities:

- Control x: control of air temperature (discharge temperature, suction temperature, room temperature) via external device (DDC controller)

- Control y: control of evaporating temperature via Daikin control (no DDC controller needed)

- Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed)

› Wide range of expansion valve kits available

DDC controller

(field supplied)

control x

Liquid pipe

Gas pipe

Expansion valve kit :

EKEXV

Control box (cooling only):

EKEQDCB : control z

EKEQFCB : control x,y

F1,F2 communication

Air handling unit

Liquid pipe

Gas pipe

COMBINATION TABLE

Outdoor unit

Control box Expansion valve kit

control zcontrol x or y

class 63 class 80 class100 class 125 class 140 class 200 class 250

EKEQDCBA EKEQFCBA EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250

1~

ERQ100AV1 P P P P P P - - -

ERQ125AV1 P P P P P P P - -

ERQ140AV1 P P - P P P P - -

3~

ERQ125AW1 P P P P P P P - -

ERQ200AW1 P P - - P P P P P

ERQ250AW1 P P - - - P P P P

P: Pair: Combination depending on air handling units coils volume.x: Possibility to connect.

gas pipe

liquid pipe

F1-F2

other communication

Air handling application (pair)

228

ERQ

GC_pre2_lowres.pdf 228 30/11/2011 12:31:38

Page 231: DAIKIN General Catalogue 2012

Outdoor unit combined with indoor units Air handling unit ERQ

Expansion valve kitControl box

Ventilation

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air fl ow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Sound pressure level

Cooling Nom. dBA

Heating Nom. dBA

Operation range Cooling Min./Max. °CDB

Heating Min./Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Drain OD mm

Power supply Phase/Frequency/Voltage Hz/V

Ventilation

Capacity range HP

Cooling capacity Nom. kW

Heating capacity Nom. kW

Power input Cooling Nom. kW

Heating Nom. kW

EER

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Fan-Air fl ow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Nom. dBA

Sound pressure level Nom. dBA

Operation range Cooling Min./Max. °CDB

Heating Min./Max. °CWB

Refrigerant Type R-410A

Piping connections

Liquid OD mm

Gas OD mm

Power supply Phase/Frequency/Voltage Hz/V

ERQ100AV1 ERQ125AV1 ERQ140AV1

4 5 6

11.2 14.0 15.5

12.5 16.0 18.0

-

-

3.99 3.42

4.56 4.15 3.94

1,345x900x320

120

106

102 105

66 67 69

50 51 53

52 53 55

-5/46

-20/15.5

9.52

15.9 19.1

26x3

1N~/50/220-440

ERQ125AW1 ERQ200AW1 ERQ250AW1

5 8 10

14.0 22.4 28.0

16.0 25.0 31.5

3.52 5.22 7.42

4.00 5.56 7.70

3.98 4.29 3.77

4.00 4.50 4.09

1,680x635x765 1,680x930x765

159 187 240

95 171 185

95 171 185

72 78

54 57 58

-5/43

-20/15

9.52

15.9 19.1 22.2

3N~/50/400

229

GC_pre2_lowres.pdf 229 30/11/2011 12:31:38

Page 232: DAIKIN General Catalogue 2012

230

Ventilation

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Sound pressure level Nom. dBA

Operation range Cooling Min./Max. °CDB

Heating Min./Max. °CWB

Operation range - on coil temperature

Cooling Max. °CDB

Heating Min. °CDB

Refrigerant Type

Piping connections

Liquid OD mm

Gas OD mm

› The system provides optimized air conditions such as fresh air and humidity control etc. and can be used in small warehouses, showrooms and offices.

› Wide range of units offers maximum application potential and flexible control options › Control box and expansion valve kit are required for each combination plus an air handling unit › Both option kits are designed for indoor and outdoor installation and can be wall mounted.

Expansion valve kit for air handling applications

Ventilation

Application Pair Pair Multi

Outdoor unit ERQ ERQ VRV®

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Power supply Phase/Frequency/Voltage Hz/V

› Wide range of units offers maximum application potential and flexible control options › The system provides optimized air conditions such as fresh air and humidity

control etc. and can be used in small warehouses, showrooms and offices. › Control box and expansion valve kit are required for each combination plus an air handling unit › Both option kits are designed for indoor and outdoor installation and can be wall mounted. › Wide offer in control possibilities: control x: room, suction or discharge temperature can

be controlled via DDC control (field supplied); control y: control by fixed evaporating temperature; control z: room or suction temperature control via Daikin remote control; remote ON/OFF can be achieved by an optional adapter KRP4A51

Control box for air handling applications

1 45% relative humidity2 The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information

230

EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250

401x215x78

2.9

45

-5.0/46.0

-/-

351

102

R-410A

6.35 9.52

6.35 9.52

EKEQFCB EKEQDCB EKEQMCB

132x400x200

3.6 3.9 3.6

1~/50/230

230

EKEXV140

EKEXV

EKEQFCBV3

EKEQ

GC_pre2_lowres.pdf 230 30/11/2011 12:31:38

Page 233: DAIKIN General Catalogue 2012

ERQ

231

POSSIBILITY X (TD/TR CONTROL):

Air temperature control via an external DDC controller (field supplied)

Room temperature is controlled as a function of the air handling unit

suction or discharge air (customer selection). The DDC controller is

translating the temperature difference between set point and air suction

temperature (or air discharge temperature or room temperature) into a

reference voltage (0-10V) which is transferred to the Daikin control box

(EKEQFCBA). This reference voltage will be used as the main input value

for the compressor frequency control.

POSSIBILITY Y (TE/TC CONTROL):

By fixed evaporating temperature

A fixed target evaporating temperature of between 3°C and 8°C can be

set by the customer. In this case, room temperature is only indirectly

controlled. The cooling load is determined from the actual evaporating

temperature (i.e. load to the heat exchanger). A Daikin wired remote

controller (BRC1D52 or BRC1E51A - optional) can be connected for error

indication.

POSSIBILITY Z (TD/TR CONTROL):

Using Daikin wired remote controller (BRC1D52 or BRC1E51A - optional)

Set point can be fixed via standard Daikin wired remote controller.

Remote ON/OFF can be achieved by an optional adapter KRP4A51.

No external DDC controller should be connected. The cooling load

is determined from the air suction temperature and set point on the

Daikin controller.

DDC

Ts

TR

Te

AHU

Room

Td

Ts

TR

Te

AHU

Room

Td

Daikincontrol box:

EKEQFCB

Daikincontrol box:

EKEQFCB

BRC1D52BRC1E51A

BRC1D52BRC1E51A

Ts

TR

Te

AHU

Room

Td

Daikincontrol box:

EKEQDCB EKEQMCB

KRP4A51

ON / OFF

Ts = Air suction temperatureTd = Air discharge temperatureTr = Room temperatureTe = Evaporating temperatureAHU = Air Handling UnitDDC = Digital Display Controller

* EKEQMCB (for ’multi’ application)

In order to maximise installation flexibility, 3 types of control systems are offered:

Control possibilities for air handling applications

OPTION KIT FEATURES

Possibility x

EKEQFCB

Field supplied DDC controller is requiredTemperature control using air suction or air discharge temperature

Possibility y Using fixed evaporating temperature, no set point can be set using remote controller

Possibility zEKEQDCB

EKFQMCB*Using Daikin wired remote controller BRC1D52 or BRC1E51ATemperature control using air suction temperature

GC_pre2_lowres.pdf 231 30/11/2011 12:31:38

Page 234: DAIKIN General Catalogue 2012

› Connectable to VRV® heat recovery and heat pump › VRV® is among the fi rst DX systems suitable for connection to air curtains › A payback period of less then 1.5 years compared

to installing an electric air curtain › Provides virtually free air curtain heating via recovered

heat from indoor units in cooling mode1

› Easy and quick to install at reduced costs since no additional water systems, boilers and gas connections are required

› All year round comfort ensured by the constant discharge velocity and adjustable jet airfl ow width (European patent)

› Maximum energy effi ciency stemming from almost zero down fl ow turbulence, optimised air fl ow and the application of advanced discharge rectifi er technology

› Around 85% air separation effi ciency, greatly reducing both heat loss and required indoor unit heating capacity

Biddle comfort air curtain

1 in case of connection to a VRV® heat recovery outdoor unitF: Freehanging model, C: Cassette model, R: Recessed model

Contact your local dealer for availability

BIDDLE COMFORT AIR CURTAIN (CA)

NETWORK SOLUTION VRV®

Small Medium

Indoor units CAVS100DK80*BC/*SC CAVS150DK80*BC/*SC CAVS200DK100*BC/*SC CAVS250DK140*BC/*SC CAVM100DK80*BC/*SC CAVM150DK80*BC/*SC CAVM200DK100*BC/*SC CAVM250DK140*BC/*SC

Heating capacity Speed 3 kW

Speed 4 kW

Power input Fan only Nom. kW

Heating Nom. kW

Delta T Speed 3 K

Speed 4 K

Casing Colour BC:RAL9010 / SC:RAL 9006

Dimensions Height Unit F/C/R mm

Width Unit F/C/R mm

Depth Unit F/C/R mm

Required ceiling void > mm

Door height Favorable/Normal/ Unfavorable conditions

m

Door width Max. m

Weight Unit Unit F/C/R kg

Fan-Air fl ow rate Heating Speed 3 m³/h

Heating Speed 4 m³/h

Sound pressure level Heating Speed 3 dBA

Heating Speed 4 dBA

Refrigerant Type R-410A

Piping connections Liquid (OD) / Gas mm

Required accessories (should be ordered separately) Daikin wired remote control (BRC1E51A or BRC1D52)

Power supply Voltage V 230

Large XLarge

Indoor units CAVL100DK125*BC/*SC CAVL150DK200*BC/*SC CAVL200DK250*BC/*SC CAVL250DK250*BC/*SC CAVXL100DK125*BC/*SC CAVXL150DK200*BC/*SC CAVXL200DK250*BC/*SC CAVXL250DK250*BC/*SC

Heating capacity Speed 3 kW

Speed 4 kW

Power input Fan only Nom. kW

Heating Nom. kW

Delta T Speed 3 K

Speed 4 K

Casing Colour BC:RAL9010 / SC:RAL 9006

Dimensions Height Unit F/C/R mm

Width Unit F/C/R mm

Depth Unit F/C/R mm

Required ceiling void > mm

Door height Favorable/Normal/ Unfavorable conditions

m

Door width Max. m

Weight Unit Unit F/C/R kg

Fan-Air fl ow rate Heating Speed 3 m³/h

Heating Speed 4 m³/h

Sound pressure level Heating Speed 3 dBA

Heating Speed 4 dBA

Refrigerant Type R-410A

Piping connections Liquid (OD) / Gas mm

Required accessories (should be ordered separately) Daikin wired remote control (BRC1E51A or BRC1D52)

Power supply Phase / Frequency / Voltage Hz / V 230

4.8 6.1 7.9 10.9 6.1 7.5 9.7 13.4

6.0 7.5 9.7 13.3 7.7 9.4 12.1 16.8

0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70

0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70

22 19 18 20 20 17 16 18

20 17 16 18 15 14 16

270 / 270 / 270

1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548

590 / 821 / 561

420

2.4 / 2.2/ - 2.8 / 2.5 / 2.2

1.0 1.5 2.0 2.5 1.0 1.5 2.0 2.5

61 / 59 / 61 73 / 83 / 88 89 / 102 / 108 101 / 129 / 137 66 / 68 / 66 79 / 88 / 93 97 / 111 / 117 119 / 136 / 144

670 1,000 1,340 1,670 750 / 890 1,120 / 1,330 1,490 / 1,770 1,870 / 2,215

880 1,310 1,750 2,190 890 / 1,230 1,330 / 1,840 1,770 / 2,450 2,220 / 3,060

36 38 39 40 32 / 37 34 / 39 35 / 40 36 / 41

42 44 45 46 37 / 45 39 / 47 40 / 48 4 / 49

9.52 / 16.0 9.52 / 19.0 9.52 / 16.0 9.52 / 19.0

10.6 15.9 20.3 22.1 12.3 18.6 23.6 25.4

12.5 18.8 24.0 25.8 14.7 22.0 27.8 29.6

0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50

0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50

18 15 17 16 14

17 16 14 15 12

370 / 370 / 370

1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548

774 / 1,105 / 745

520

3.3 / 3.0 / 2.5 3.8 / 3.5 / 3.0

1.0 1.5 2.0 2.5 1.0 1.5 2.0 2.5

83 / 81 / 83 108 / 118 / 141 137 / 151 / 155 166 / 190 / 196 69 / 84 / 86 102 / 123 / 146 130 / 160 / 164 162 / 198 / 204

1,330 / 1,730 2,000 / 2,600 2,670 / 3,470 3,330 / 4,340 1,610 / 2,160 2,420 / 3,250 3,230 / 4,330 4,030 / 5,410

1,730 / 2,210 2,600 / 3,320 3,470 / 4,430 4,340 / 5,530 2,160 / 2,800 3,250 / 4,190 4,330 / 5,590 5,410 / 6,990

40 / 46 42 / 48 43 / 49 44 / 50 46 / 52 48 / 53 49 / 55 50 / 56

45 / 51 47 / 53 48 / 54 49 / 55 51 / 56 53 / 58 54 / 59 55 / 60

9.52 / 16.0 9.52 / 19.0 9.52 / 22.0 9.52 / 16.0 9.52 / 19.0 9.52 / 22.0

CAVS/M/L/XL-DK-F/C/R

CAVM150DK80FSC

232

GC_pre2_lowres.pdf 232 30/11/2011 12:31:39

Page 235: DAIKIN General Catalogue 2012

Biddle standard air curtain

ERQ

SEPARATE SYSTEM FOR HEATING OR COOLING

BIDDLE STANDARD AIR CURTAIN (CY)

F: Freehanging model, C: Cassette model, R: Recessed model

(1) Favourable condition | (2) Normal condition | (3) Unfavourable condition

› Connectable to ERQ heat pump › ERQ is among the first DX system suitable for connection to air curtains › Free-hanging model (F): easy wall mounted installation › A payback period of less then 1.5 years compared

to installing an electric air curtain › Easy and quick to install at reduced costs since no additional

water sytems, boilers and gas connections are required › Maximum energy efficiency stemming from almost

zero down flow turbulence, optimised air flow and the application of advanced discharge rectifier technology

› Around 85% air separation efficiency, greatly reducing both heat loss and required indoor unit heating capacity

LargeBiddle standard air curtain for connection to ERQ

Power input Fan only Nom. kW

Heating Nom. kW

Delta T Inlet= room temperature K

Casing Colour BN: RAL9010 / SN: RAL9006

Dimensions Height Unit F/C/R mm

Width Unit F/C/R mm

Depth Unit F/C/R mm

Required ceiling void > mm

Door height Max. m

Door width Max. m

Weight Unit kg

Fan-Air flow rate Heating m³/h

Sound pressure level Heating dBA

Refrigerant Type R-410A

Piping connections Liquid (OD) / Gas

Required accessories (should be ordered separately) Daikin wired remote control (BRC1E51A or BRC1D52)

Power supply Voltage V

Small MediumBiddle standard air curtain for connection to ERQ

Power input Fan only Nom. kW

Heating Nom. kW

Delta T Inlet= room temperature K

Casing Colour BN: RAL9010 / SN: RAL9006 BN: RAL9010 / SN: RAL9006

Dimensions Height Unit F/C/R mm

Width Unit F/C/R mm

Depth Unit F/C/R mm

Required ceiling void > mm

Door height Max. m

Door width Max. m

Weight Unit kg

Fan-Air flow rate Heating m³/h

Sound pressure level Heating dBA

Refrigerant Type R-410A R-410A

Piping connections Liquid (OD) / Gas

Required accessories (should be ordered separately) Daikin wired remote control (BRC1E51A or BRC1D52) Daikin wired remote control (BRC1E51A or BRC1D52)

Power supply Voltage V

CYQL100DK125F*BN / *SN CYQL150DK200F*BN / *SN CYQL200DK250F*BN / *SN CYQL250DK250F*BN / *SN

0.75 1.13 1.50 1.88

0.75 1.13 1.50 1.88

15 14 12

370 / 370 / 370

1,000 / 1,000 / 1,048 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548

745 / 745 / 745

520

3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3)

1.0 1.5 2.0 2.5

76 100 126 157

3,100 4,650 6,200 7,750

53 54 56 57

9.52 / 16.0 9.52 / 16.0 9.52 / 22.0

230

CYQS150DK80F*BN / *SN CYQS200DK100F*BN / *SN CYQS250DK140F*BN / *SN CYQM100DK80F*BN / *SN CYQM150DK80F*BN / *SN CYQM200DK100F*BN / *SN CYQM250DK140F*BN / *SN

0.35 0.46 0.58 0.37 0.56 0.75 0.94

0.35 0.46 0.58 0.37 0.56 0.75 0.94

15 16 17 14 13 15

270 / 270 / 270 270 / 270 / 270

1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 1,000 / 1,000 / 1,048 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548

290 / 821 / 561 290 / 821 / 561

420 420

2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3)

1.5 2.0 2.5 1.0 1.5 2.0 2.5

66 83 107 57 73 94 108

1,746 2,328 2,910 1,605 2,408 3,210 4,013

49 50 51 50 51 53 54

9.52 / 16.0 9.52 / 19.0 9.52 / 16.0 9.52 / 19.0

230 230

233

CYQS/M/L-DK-F/C/R

CYQM150DK80FSN

GC_pre2_lowres.pdf 233 30/11/2011 12:31:39

Page 236: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 234 30/11/2011 12:31:39

Page 237: DAIKIN General Catalogue 2012

The marine branch office of Daikin Europe N.V., named Daikin Europe N.V. Hamburg Marine

Office is located in the heart of one of the biggest harbour towns in the entire Europe.

Through this decision, Daikin Europe N.V. aims to establish a firm basis to further increase

its presence in the European Marine A/C market. The portfolio of products are focused on

Marine application, such as Daikin - Packaged Marine Air conditioners, Chillers and DX- units

in accordance to most of the well known classification societies for which Daikin Europe

Hamburg Marine Office is your competent partner.

* ,.���234�5USDP*GC / USDN*HA 236

USP~HR1 / USP~H 236

USF*J(A) 237

RHSD~A / RKS~FR 237

235

GC_pre2_lowres.pdf 235 30/11/2011 12:31:40

Page 238: DAIKIN General Catalogue 2012

Daikin marine type deck units

Daikin Marine Type Packaged Series

› Energy saving › Compact design › Refrigerants R-404A - R-407C › Economical maintenance › Easy installation › Hermetic scroll compressor › Minimum piping and field work required › High performance reliability › Lesser refrigerant volum with leak proof hermetic structure › High static pressure fan facilitates the use of long ducts › Quiet, less vibration operation makes it suitable for installation in accomodation areas

Optional customized modifications: › Remote controls › Electrical heater › Data bus interfaces › Air plenum or duct connection › Higher external static pressure › Cooling water regulating valve › Higher air volume

Optional customized modifications: › Remote controls › Electrical heater › Data bus interfaces › Air plenum or duct connection › Higher external static pressure › Cooling water regulating valve › Higher air volume

For more information, visit http://www.daikin.eu/product/industrial/marine

› Excellent durability › Hermetic scroll compressor › Light weight design › Refrigerants: R-404A - R-407C › Resilient structure specially designed for marine applications › Abundant modification parts assures various applications › Wide operation range › Easy transportation and installation › Energy-saving › Complete set of spare parts provided for certain models

USDP*GC / USDN*HA

USP~HR1 / USP~H

236

GC_pre2_lowres.pdf 236 30/11/2011 12:31:40

Page 239: DAIKIN General Catalogue 2012

Daikin Marine Type Galley Series

Daikin Marine Type Small Size Condensing Unit

› Respond to a wide temperature range › High efficient operation › Outstanding durable design › Easy transportation and installation › Excellent performance reliability › Spare parts are provided as standard accessories › Hermetic scroll compressor › High static pressure system › R-404A

Optional customized modifications: › Remote controls › Electrical heater › Data bus interfaces › Air plenum or duct connection › Higher external static pressure › Cooling water regulating valve › Higher air volume

For more information, visit http://www.daikin.eu/product/industrial/marine

RHSD-A (R-134a): › A semi-hermetic reciprocating compressor with proven reliability › Saved maintenance work around compressor (without V belts & shaft seal)

RKS-FR (R-404A): › An open type reciprocating compressor of optimum design for R-404A › Equal installation & maintenance as R-22

USF*J(A)

RHSD~A / RKS~FR

237

GC_pre2_lowres.pdf 237 30/11/2011 12:31:40

Page 240: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 238 30/11/2011 12:31:40

Page 241: DAIKIN General Catalogue 2012

239

APPLIED SYSTEMSCHILLERS 240

Air cooled chiller (Cooling only) 244

EWAQ-ACV3 244

EWAQ-ACW1 245

EUWAC-FBZW1 246

EUWA(N-P-B)-KBZW1 247

EWAQ-BAWN/BAWP 248

EWAQ-DAYN 249

EWAD-E- 250

EWAD-D- 252

EWAD-BZ 260

EWAD-C- 262

EWAD-CZ 268

EWAD-CF 270

Air cooled chiller (Heat pump) 272

EWYQ-ACV3 272

EWYQ-ACW1 273

EUWY(N-P-B)-KBZW1 274

EWYQ-BAWN/BAWP 275

EWYQ-DAYN 276

EWYD-BZ 277

Air cooled condensing unit 279

ERAD-E- 279

Water cooled chiller 281

EWWQ-B- 281

EWWP-KBW1N 283

EWWD-J- 285

EWWD-G- 286

EWWD-I- 288

EWWD-H- 290

Condenserless chiller 291

EWLP-KBW1N 291

EWLD-J- 292

EWLD-G- 293

EWLD-I- 294

Water cooled centrifugal chiller 295

EWWD-FZXS 295

DWSC, DWDC 296

Accessories 298

DICN (Daikin Integrated Chiller Network) 298

EHMC, EKBT (Hydraulic Module, Buff er tank) 299

FAN COIL UNITS 301

FWC-BT/BF 303

FWF-BT/BF 304

FWC-AT/AF 305

FWF-CT 306

FWB-BT 307

FWB-JT/JF 308

FWT-BT/BF 309

FWL-DT/DF 310

FWM-DT/DF 311

FWD-AT/AF 312

FWV-DT/DF 313

AIR HANDLING UNITS 314

D-AHU Professional 314

D-AHU Easy 316

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

For more information on Options & Accessories, please refer to page 358 of this catalogue.

GC_pre2_lowres.pdf 239 30/11/2011 12:31:41

Page 242: DAIKIN General Catalogue 2012

240

��������

Refrigeran

t

Inverter

Free cooling Compressor Effi ciency version Sound version

Swing

Scro

ll

Screw

Cen

trifu

gal

Stan

dard

High

Prem

ium

High am

bient

Stan

dard

Low

Redu

ced

Extra

low

Air cooled chillers (Cooling only)

EWAQ005-007ACV3 R-410A � � � �

EWAQ009-011ACV3 R-410A � � � �

EWAQ-ACW1 R-410A � � � �

EUWAC-FBZW1 R-407C � � �

EUWA*-KBZW1 R-407C � � �

EWAQ-BAWN/BAWP R-410A � � � �

EWAQ-DAYN R-410A � � �

EWAD-E- R-134a � � � �

EWAD-D- R-134a � � � � � � � �

EWAD-BZ R-134a � � � � � � �

EWAD-C- R-134a � � � � � � �

EWAD-CZ R-134a � � � � � �

EWAD-CF R-134a � � � � � �Air cooled chillers (Heat pump)

EWYQ005-007ACV3 R-410A � � � �

EWYQ009-011ACV3 R-410A � � � �

EWYQ-ACW1 R-410A � � � �

EUWY*-KBZW1 R-407C � � �

EWYQ-BAWN/BAWP R-410A � � � �

EWYQ-DAYN R-410A � � �

EWYD-BZ R-134a � � � � �Air cooled condensing unit

ERAD-E- R-134a � � � �

General chiller overviewPortfolio Air cooled units

GC_pre2_lowres.pdf 240 30/11/2011 12:31:41

Page 243: DAIKIN General Catalogue 2012

241241

Capacity classes (kW)

0 17.5 200 500 1,000 2,000

0 17.5 200 500 1,000 2,000

0 17.5 200 500 1,000 2,000

5.2~7.1

5.2~7.1

8.5~11.0

8.5~11.0

9~13.2

9.0~13.2

11.6~23.8

11.3~55.3

9.1~50.0

16.8~63.0

16.8~63

80~254

77~252

97.9~413

177~622

329~515

116~488

248~583

619~2,008

635~1,802

602~1,555

270~615

88.7~281

16.8~63

11.9~54.0

11~14

10.0~13.0

5.65~7.75

GC_pre2_lowres.pdf 241 30/11/2011 16:04:45

Page 244: DAIKIN General Catalogue 2012

242

��������

Refrigeran

t

Inverter

Free cooling Compressor Effi ciency version Sound version

Swing

Scro

ll

Screw

Cen

trifu

gal

Stan

dard

High

Prem

ium

High am

bient

Stan

dard

Low

Redu

ced

Extra

low

Water cooled chillers (Cooling only & Heating only)

EWWP-KBW1N R-407C � � �

EWWD-J- R-134a � � �

EWWD-G- R-134a � � � �

EWWD-I- R-134a � � � �

EWWD-H- R-134a � � �Water cooled chillers (Cooling only)

EWWQ-B- R-410A � � � �Condenserless chillers

EWLP-KBW1N R-407C � � �

EWLD-J- R-134a � � �

EWLD-G- R-134a � � �

EWLD-I- R-134a � � �Water cooled centrifugal chillers

EWWD-FZXS R-134a � � � �DWSC

DWDCR-134a � � � �

Portfolio Water cooled and condenserless units

GC_pre2_lowres.pdf 242 30/11/2011 12:31:42

Page 245: DAIKIN General Catalogue 2012

243243

Capacity classes (kW)

0 17.5 200 500 1,000 2,000 9,000

0 17.5 200 500 1,000 2,000 9,000

0 17.5 200 500 1,000 2,000 9,000

0 17.5 200 500 1,000 2,000 9,000

13.0~195

120~570

166~604

333~1,510

369~1,215

300~4,500

16.6~248

142~681

204~712

388.4~1,790

419~1,356

600~9,000

380~2,152

12.1~62.4

110~530

161~526

328~1,422

114~1,048

GC_pre2_lowres.pdf 243 30/11/2011 12:31:42

Page 246: DAIKIN General Catalogue 2012

244

Air cooled mini chiller inverter

› Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.57), significant reduction of starting currents, precise temperature control (evaporator leaving water)

› Low operating sound level › Easy ‘plug and play’ installation › Daikin swing (sizes 005-006-007) or scroll compressor (sizes 009-010-011) › Integrated hydronics › Available options: evaporator heater type (OP10)

and high ESP pump up to 90 kPa (OPHP) › Single phase power supply and main switch included › Wide operating range

Cooling onlyCapacity class 005 006 007 009 010 011

Cooling capacity Nom. kWPower input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow

Cooling l/min

Air heat exchanger Type Tube type Hi-XSSPump Nominal ESP unit Cooling kPaHydraulic components Expansion vessel Volume l

Fan Air flow rate Cooling Nom. m³/minFan motor Speed Cooling Nom. rpm

StepsSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBANight quiet mode Cooling dBA

Compressor Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Water circuit Piping connections diameter inch G 5/4" (female)Piping inch

Piping

connectionsWater heat exchanger inlet / outletWater heat exchanger drain Hose nipple 1/2" FBSP

Power supply Phase / Frequency / Voltage Hz / V

Digital controller

244

5.2 6.0 7.1 8.5 9.5 11.0

1.89 2.35 2.95 2.74 3.19 3.82

2.75 2.55 2.41 3.11 2.98 2.88

3.75 3.83 3.87 4.57 4.52 4.46

805x1,190x360 1,435x1,418x382100 180

- 1.01

14.9 17.2 20.4 24.4 27.2 31.5

49.4 45.1 38.3 58.0 54.6 49.16 10- 96 100 97- 780- 8

62 63 64

48 50 51

- 45

5~20 5~2210~43 10~46

1.7 2.95

1

-

- 5/4"

1" MBSP -

-

1~ / 50 / 230

244

EWAQ-ACV3

EWAQ005-011ACV3

GC_pre2_lowres.pdf 244 30/11/2011 12:31:42

Page 247: DAIKIN General Catalogue 2012

245

Cooling onlyCapacity class 009 011 013Cooling capacity Nom. kWPower input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow Cooling l/minAir heat exchanger Type Hi-XSSPump Nominal ESP unit Cooling kPaHydraulic components Expansion vessel Volume l

Fan motor Speed Cooling Nom. rpmSteps

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBANight quiet mode Cooling dBA

Compressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Water circuit Piping connections diameter inch G 5/4" (female)Piping inch

Power supply Phase / Frequency / Voltage Hz / V

Air cooled mini chiller inverter

› Excellent part load efficiency (ESEER up to 4.68) › Low operating sound level › Easy ‘plug and play’ installation › Daikin scroll compressor › Integrated hydronics › Available options: evaporator heater type (OP10)

and high ESP pump up to 90 kPa (OPHP) › Three phase power supply and main switch included › Wide operating range

Digital controller

245

9.0 11.0 13.22.96 3.82 5.10

3.04 2.88 2.59

4.68 4.63 4.521,435x1,418x382

180

1.01

25.8 31.5 37.8

56.4 49.1 40.9107808

64 66

51 5245 46

5~2210~46

2.95

1

5/4"

3N~ / 50 / 400

245

EWAQ-ACW1

EWAQ009-013ACW1

GC_pre2_lowres.pdf 245 30/11/2011 12:31:42

Page 248: DAIKIN General Catalogue 2012

246

Cooling onlyCapacity class 5 8 10Cooling capacity Nom. kWCapacity steps %

Power input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Brazed plate, one per circuitMinimum water volume in the system l

Water flow rate Nom. l/minNominal water pressure drop

Cooling Heat exchanger

kPa

Model Type AC70-24 AC70-34 AC70-40Quantity

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsFan Air flow rate Nom. m³/minSound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-407C

Control Thermostatic expansion valveCircuits Quantity

Refrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet FBSP 1"

Evaporator water drain Field installationPower supply Phase / Frequency / Voltage Hz / V

› Optimised for use with R-407C › Daikin scroll compressor › Electronic DDC controller › Standard phase sequence controller › Maximum external static pressure (ESP): 150Pa › Pressure gauges › Standard operation range down to -10°C › Regulating switch › Water inlet or outlet temperature control › Input contacts/available outputs › Input: on/off (per circuit), pump/flow switch › Outputs: compressor operation, summary alarm, pump relay contact › Compatible with hydraulic module

› μC² SE controller

Air cooled chiller with centrifugal fan

246

11.6 18.4 23.8100-0

5.2 7.66 9.672.23 2.40 2.46

1,345x856x630 1,290x1,180x630 1,395x1,330x630164 224 261

166 228 266

101 153 21233 53 68

26 42 48

1

70.2 109.8 126

63 66 69

-10 (OPZL) ~ 21

-10 ~ 43

1

2.1 3.9 4.7

3N~ / 50 / 400

246

EUWAC8FBZW1

EUWAC-FBZW1

μC² SE

GC_pre2_lowres.pdf 246 30/11/2011 12:31:43

Page 249: DAIKIN General Catalogue 2012

247

Cooling onlyCapacity class N5 P5 B5 N8 P8 B8 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24

Cooling capacity Nom. kWCapacity steps %

Power input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow Cooling l/minNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsHydraulic components Expansion vessel Volume l

Fan group Air flow rate Cooling Nom. m³/min 160 (per 2 fans) 170 (per 2 fans)Fan group 2 Air flow rate Cooling Nom. m³/min - 170 (per 2 fans)Sound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-407C

Control Thermostatic expansion valveCircuits Quantity

Refrigerant circuit Charge kgRefrigerant circuit 2 Charge kgWater circuit Piping connections diameter inch G 1"1/4 (male)

Piping inchPower supply Phase / Frequency / Voltage Hz / V

› Optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to integrated pump and;or buffer tank › Possibility for a 200l buffer tank › Low operating sound level › Easy maintenance › Main switch › Water flow switch › 3 different design options available:

- EUWAN chiller without integrated hydraulic module ; - EUWAP chiller with integrated hydraulic module (pump,

expansion vessel, hydraulic components) ; - EUWAB chiller with integrated hydraulic module (buffer

tank, pump, expansion vessel, hydraulic components)

› μC² SE controller

Air cooled chiller

247

11.3 19.7 22.5 26.5 34.6 46.6 55.3

0-100 0-50-1004.48 7.27 8.64 11.50 14.70 17.90 23.802.53 2.46 2.60 2.30 2.35 2.60 2.32

1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734

150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526

152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592

1.14 1.615 1.9 2.375 2.964 3.9 4.524

32 51 64 76 99 134 158

24 38 43 37 22

- 12 - 12 - 12 - 12 - 12 - 12 - 12

67 76 78 79 81

-10 (OPZL) ~ 25-15 ~ 43

1 23.9 4.6 5.9 6.0 4.6 5.9 6.0

- 4.6 5.9 6.02" male

1-1/4" 2"

3N~ / 50 / 400

247

EUWA*16KBZW1

EUWA(N-P-B)-KBZW1

μC² SE

GC_pre2_lowres.pdf 247 30/11/2011 12:31:43

Page 250: DAIKIN General Catalogue 2012

248

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Inverter controlled

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow

Cooling l/minHeating l/min

Nominal water pressure drop Cooling Total kPaAir heat exchanger Type Hi-XSSFan Air flow rate Cooling Nom. m³/minSound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Water circuit Piping inchPower supply Phase/Frequency/Voltage Hz/V

› High efficiency chiller with leader-of-class ESEER (up to 4.75) › Minimal starting currents and short payback times › No buffertank required for standard applications › Naked or with factory mounted (standard/high-ESP) pump › Low sound thanks to inverter compressor / fans › EWAQ-BAWN: Naked › EWAQ-BAWP: With pump

Air cooled inverter chiller

248

016 021 025 032 040 050 064

16.8 21.0 25.2 31.5 42.0 50.4 63.0

255.57 7.25 9.25 12.9 14.9 19.0 26.73.01 2.90 2.72 2.44 2.82 2.65 2.36

4.75 4.65 4.45 4.00 4.60 4.40 3.951,684x1,371x774 1,684x1,684x774 1,684x2,358x780 1,684x2,980x780

264 317 397 571 730267 320 401 577 738

1 2 3 548 60 72 90 120 144 181

48 60 72 90 120 144 181

20 30 42 30 42 30

171 185 233 370 466.078 80 81 83

5~20-5~43

7.6 9.6 15.2 19.2

1

1-1/4” 1-1/2"

3N~/50/400

248

EWAQ-BA*

BRC21A52

EWAQ-BAWN/BAWP

GC_pre2_lowres.pdf 248 30/11/2011 12:31:43

Page 251: DAIKIN General Catalogue 2012

249

Cooling onlyCapacity class 080 100 130 150 180 210 240 260Cooling capacity Nom. kWCapacity steps %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plateNominal water flow Cooling l/minNominal water pressure drop

Cooling Total kPa

Air heat exchanger Type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsFan Air flow rate Nom. m³/min

Speed rpmSound power level Cooling Nom. dBACompressor Type Scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Piping

connectionsWater heat exchanger inlet / outletWater heat exchanger drain

Power supply Phase / Frequency / Voltage Hz / V

Air cooled chiller, multiple scroll

› Optimised for use with R-410A refrigerant › Multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › Low operating sound level › Easy 'plug and play' installation › Fans protected against abnormal operation

(4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from 3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent refrigerant

circuits (EWAQ130-260DAYN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin Pcaso controller with user friendly and powerful LCD interface

249

80 105 131 152 182 209 236 254

0-50-100 0-25-50-75-10021/29-

43/50/57-

71/79-1000-25-50-75-100

22/28-

40/50/56-

72/78-1000-25-50-75-100

26.4 36.2 46.6 56.3 64.5 74.6 82.8 94.03.03 2.90 2.81 2.70 2.82 2.80 2.85 2.704.12 4.00 4.34 4.22 4.36 4.32 4.20 4.002,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850

1,350 1,400 1,500 1,550 1,800 1,850 3,150 3,2501,365 1,415 1,517 1,569 1,825 1,877 3,189 3,292

229 301 377 436 522 599 677 728

59 58 52 49 52 53 51 47

780 800 860 1,290 1,600880 900 970 90086 88 89 90 91

-10 (OPZL) ~ 25-15 ~ 43

33 19 25 29 28 39

1 23" OD 3"

1/2"G

3~ / 50 / 400

249

EWAQ-DAYN

PCASO

EWAQ130-150DAYN

GC_pre2_lowres.pdf 249 30/11/2011 12:31:43

Page 252: DAIKIN General Catalogue 2012

250

Cooling only Standard soundCapacity class 100 120 140 160 180 210 260 310 360 410Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Plate to plateWater volume l

Nominal water flow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

Air cooled chiller, standard efficiency

› Wide capacity range: 10 sizes to cover a range from 101 to 413 kW (SS), 97.9 to 398kW (SL)

› One refrigerant circuit with single screw compressor › Compact design with brazed plate heat exchanger › Large operation range (ambient temperature down to -18°C) › Low operating sound level (SL) › Water supply down to -15°C › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication

250

101 121 138 163 183 214 256 307 360 413

2538.7 46.9 53.4 60.3 68.5 71.7 86.7 111 133 146

2.61 2.57 2.58 2.70 2.67 2.98 2.95 2.77 2.71 2.84

2.93 2.75 2.93 2.81 3.02 3.18 3.05 3.23 3.34

2,273x1,292x2,165 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,0701,684 1,861 2,086 2,9191,699 1,881 2,116 2,963

12 15 17 20 24 30 25 30 36 44

4.83 5.76 6.58 7.77 8.74 10.22 12.22 14.65 17.21 19.74

24 25 24 22 21 48 45

10,922 10,575 16,383 15,863 21,844 21,150 32,767 31,725920

91.5 92.3 93.0 94.2 94.5 95.273.5 73.7 73.9 75.1 75.0 75.3 76.0

-15~15-18~48

18 21 23 28 30 33 46 56 601

3"

3~ / 50 / 400

250

EWAD-E-SS

EWAD130,140,160E-

MicroTech III

GC_pre2_lowres.pdf 250 30/11/2011 12:31:44

Page 253: DAIKIN General Catalogue 2012

251

Cooling only Low soundCapacity class 100 120 130 160 180 210 250 300 350 400Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Plate to plateWater volume l

Nominal water fl ow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

251

97.9 116 134 157 177 209 249 296 345 398

2538.8 47.9 53.0 60.6 67.8 72.1 84.5 110 134 1502.52 2.42 2.53 2.60 2.61 2.89 2.95 2.69 2.58 2.653.01 2.97 2.85 3.00 3.07 3.32 3.55 3.41 3.34 3.452,273x1,292x2,165 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070

1,784 1,961 2,186 3,0291,799 1,981 2,216 3,073

12 15 17 20 24 30 25 30 36 44

4.68 5.54 6.40 7.51 8.47 9.97 11.90 14.15 16.50 19.01

23 21 20 46 45 44 42

8,372 8,144 12,558 12,217 16,744 16,289 25,117 24,433715

89.0 89.8 90.5 91.7 92.0 92.771.0 71.2 71.4 72.6 72.5 72.8 73.5

-15~15-18~48

18 21 23 28 30 33 46 56 601

3"

3~ / 50 / 400

251

EWAD-E-SL

GC_pre2_lowres.pdf 251 30/11/2011 12:31:44

Page 254: DAIKIN General Catalogue 2012

252

Cooling only Standard soundCapacity class 390 440 470 510 530 560 580Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› Standard efficiency level › Standard sound level configuration: condenser fan rotating

at 920 rpm, rubber antivibration under compressor (SS) › Low sound level configuration: condenser fan rotating at 715/900 rpm,

rubber antivibration under compressor, compressor sound enclosure (SL) › Stepless single-screw compressor › Optimised for use with R-134a › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication › Large operation range (ambient temperature down to -18°C)

Air cooled chiller, standard efficiency

252

389 436 466 502 532 556 578

12.5152 164 167 184 194 205 1972.56 2.66 2.79 2.73 2.74 2.72 2.933.36 3.54 3.55 3.52 3.56 3.39

2,223x2,234x3,139 2,223x2,234x4,0402,960 4,030 4,220 4,230 4,2353,090 4,195 4,395

130 165 175 165 160

18.60 20.80 22.20 24.00 25.40 26.50 27.60

45.6 37.9 66.5 47.1 52.1 57.4 51.2

32,772 43,694 43,455 43,694 42,300920

95.8 96.7 96 96.7 98.2 98.7

76.5 77.0 78.5 79.0

-15~15-18~48

256 60 70 76 82 87 92

139.7mm

3~ / 50 / 400

252

EWAD-D-SS

EWAD390D-

MicroTech III

GC_pre2_lowres.pdf 252 30/11/2011 12:31:44

Page 255: DAIKIN General Catalogue 2012

253

Cooling only Low soundCapacity class 180 200 230 250 260 280 300 320 370 400 440 480 510 530

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Plate to plate Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz/V

253

184 198 225 245 261 275 298 321 370 404 440 477 505 533

12.581.4 79.7 84.5 93.4 101 108 119 123 133 169 170 186 203 1952.26 2.48 2.66 2.62 2.58 2.54 2.50 2.60 2.78 2.39 2.59 2.57 2.49 2.733.00 3.12 3.31 3.21 3.26 3.23 3.20 3.24 3.41 3.65 3.67 3.57 3.67 3.77

2,355x2,234x2,239 2,355x2,234x3,139 2,223x2,234x3,139 2,223x2,234x4,0402,475 2,470 2,860 2,960 4,029 4,224 4,229 4,234

2,500 2,960 3,090 4,194 4,394

25 30 100 130 165 170 165 160

8.80 9.40 10.70 11.70 12.50 13.10 14.20 15.30 17.70 19.30 21.00 22.80 24.10 25.40

28.9 21.8 57.8 49.0 53.9 58.9 59.5 55.2 67.4 47.5 62.1 54.0 48.4 43.4

15,300 14,900 22,900 22,600 22,300 24,428 33,489 32,572900 715

93.7 94.3 94.7 97.2 94.2 95.7 96.2

75.0 77.5 74.5 76.0 76.5

-15~15-18~48

236 42 48 50 54 58 66 70 76 82 84 86

88.9 114.3 139.7

3~ / 50 / 400

253

EWAD-D-SL

GC_pre2_lowres.pdf 253 30/11/2011 12:31:44

Page 256: DAIKIN General Catalogue 2012

254

Cooling only Reduced soundCapacity class 180 190 220 240 250 270 280 310 370 400 440 480 510 530

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Plate to plate Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› Standard efficiency level › Reduced sound level configuration: condenser fan rotating

at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure (SR)

› Extra low sound level configuration: condenser fan rotating at 500 rpm, rubber antivibration under compressor, compressor and evaporator sound enclosure (SX)

› Stepless single-screw compressor › Optimised for use with R-134a › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication › Large operation range (ambient temperature down to -18°C)

Air cooled chiller, standard efficiency

254

177 190 219 238 252 265 278 312 366 404 440 477 505 533

12.584.0 82.7 85.2 94.7 103 111 122 125 138 169 170 186 203 1952.11 2.30 2.57 2.51 2.44 2.38 2.28 2.49 2.65 2.39 2.59 2.57 2.49 2.732.89 3.00 3.34 3.21 3.23 3.16 3.13 3.25 3.42 3.65 3.67 3.57 3.67 3.77

2,355x2,234x2,239 2,355x2,234x3,139 2,223x2,234x3,139 2,223x2,234x4,0402,620 2,890 3,110 4,040 4,2402,650 3,100 3,240 4,342 4,542

25 30 100 130 165 170 165 160

8.50 9.10 10.40 11.30 12.00 12.60 13.30 14.90 17.40 19.30 21.00 22.80 24.10 25.40

26.9 20.1 55.1 46.6 50.8 55.2 52.7 65.1 47.5 62.1 54.0 48.4 43.4

15,300 14,900 22,900 22,600 22,300 24,428 33,489 32,572680 715

88.7 89.3 89.7 92.2 90.7 92.2 92.7

70.0 72.5 71.0 72.5 73.0

-15~15-18~48

36 42 48 50 54 58 66 70 76 82 84 86

2

88.9 114.3 139.7

3~ / 50 / 400

254

EWAD-D-SR

EWAD370D-

MicroTech III

GC_pre2_lowres.pdf 254 30/11/2011 12:31:45

Page 257: DAIKIN General Catalogue 2012

255

Cooling only Extra low soundCapacity class 210 230 250 270 290 300 310 370 410 450 490

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

255

203 231 253 271 286 299 309 370 413 451 492

12.579.9 85.2 93.5 104 114 126 136 148 169 173 187

2.54 2.71 2.70 2.59 2.50 2.37 2.27 2.49 2.44 2.60 2.63

3.39 3.63 3.52 3.55 3.44 3.39 3.25 3.24 3.49 3.61 3.582,420x2,234x3,139 2,420x2,234x4,040 2,420x2,234x4,940

3,110 3,475 3,425 3,430 3,560 4,302 4,506 4,581

3,200 3,590 3,735 4,472 4,676 4,746

90 115 165 160 175 170 165

9.70 11.00 12.10 12.90 13.70 14.30 14.70 17.70 19.70 21.50 23.50

44.7 33.8 38 38.3 34.9 37.7 40.5 44.5 43.9 50 44.8

12,900 17,900 17,200 26,495 25,933 28,625 33,116

50084.3 84.7 85.7 86.2

65.0 65.5 66.0

-15~15-18~48

256 60 65 70 76 82

114.3 139.7

3~ / 50 / 400

255

EWAD-D-SX

GC_pre2_lowres.pdf 255 30/11/2011 12:31:45

Page 258: DAIKIN General Catalogue 2012

256

Cooling only Standard soundCapacity class 250 280 300 330 350 380 400 470 520 580 620

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› High efficiency

› Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor (XS)

› Reduced sound level configuration: condenser fan rotating at 680/715 rpm, rubber antivibration under compressor, compressor sound enclosure (XR)

› Stepless single-screw compressor › Optimised for use with R-134a › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication › Large operation range (ambient temperature down to -18°C)

Air cooled chiller, high efficiency

256

247 275 302 327 351 376 401 469 524 575 622

12.579.1 87.1 94.1 104 113 120 127 150 166 181 194

3.12 3.16 3.20 3.15 3.12 3.14 3.16 3.12 3.15 3.18 3.20

3.56 3.60 3.62 3.85 3.67 3.58 3.59 3.84 4.00 4.01 3.882,355x2,234x3,138 2,355x2,234x4,040 2,223x2,234x4,040 2,223x2,234x4,940

2,905 3,285 3,235 3,240 3,510 4,670 4,6853,000 3,400 3,780 4,940

95 115 165 160 270 255

11.80 13.10 14.40 15.60 16.70 17.90 19.10 22.40 25.00 27.40 29.70

48.1 44.9 48.8 46.1 50.8 57.6 63.5 47.4 62.9 56.2 37.9

22,300 30,600 29,700 44,000 43,000 43,695 54,616

900 92096.8 97.2 98.7 99.2

77.5 79.0

-15~15-18~48

258 66 76 73 76 86 100

114.3 168.3

3~ / 50 / 400

256

EWAD-D-XS

EWAD370D-

MicroTech III

GC_pre2_lowres.pdf 256 30/11/2011 12:31:45

Page 259: DAIKIN General Catalogue 2012

257

Cooling only Reduced soundCapacity class 240 270 300 320 350 370 390 460 510 560 600

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz/V

257

243 272 296 322 345 370 394 455 512 561 600

12.580.6 87.0 95.1 106 115 119 127 152 167 183 198

3.01 3.12 3.11 3.05 2.99 3.12 3.10 2.99 3.07 3.03

3.63 3.70 3.69 3.82 3.71 4.01 3.82 3.89 4.11 3.932,355x2,234x3,138 2,355x2,234x4,040 2,223x2,234x4,040 2,223x2,234x4,940

3,005 3,385 3,335 3,340 3,610 4,770 4,7853,100 3,500 3,880 5,040

95 115 165 160 270 255

11.60 13.00 14.10 15.40 16.40 17.70 18.80 21.70 24.40 26.80 28.60

46.7 44.0 47.5 44.7 49.2 56.2 55.6 44.8 60.4 53.7 36.1

12,500 33,488 41,861 41,864

680 71591.8 92.2 93.2 93.7

72.5 73.5

-15~15-18~48

260 68 80 104

114.3 168.3

3~ / 50 / 400

257

EWAD-D-XR

GC_pre2_lowres.pdf 257 30/11/2011 12:31:45

Page 260: DAIKIN General Catalogue 2012

258

Cooling only Standard soundCapacity class 200 210 230 260 270 290 310 340 380 420 450 480 510 550 590

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Plate to plate Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/sFan motor Speed Cooling Nom. rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› High ambient

› Standard sound level configuration: condenser fan rotating at 900/920 rpm, rubber antivibration under compressor

› Stepless single-screw compressor › Optimised for use with R-134a › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications › Large operation range (ambient temperature down to -18°C)

Air cooled chiller, high ambient

258

195 208 234 256 274 289 306 336 381 415 448 478 514 547 587

12.577.2 75.5 83.0 91.0 97.7 104 112 120 127 141 150 162 175 182 191

2.52 2.76 2.81 2.80 2.78 2.73 2.80 3.00 2.94 2.98 2.95 2.94 3.00 3.07

3.11 3.26 3.34 3.21 3.30 3.28 3.27 3.25 3.57 3.61 3.68 3.66 3.71 3.792,223x2,234x2,239 2,223x2,234x3,339 2,223x2,234x4,040 2,223x2,234x4,9402,475 2,470 2,865 2,870 3,185 3,277 3,942 4,356 4,361 4,366

2,500 2,960 3,300 3,447 4,112 4,526

25 30 95 90 115 170 165 160

9.30 9.90 11.10 12.20 13.10 13.80 14.60 16.00 18.20 19.80 21.40 22.80 24.50 26.10 28.00

31.5 23.7 46.1 52.1 53.7 59.3 64.4 58.3 69.9 45.8 52.5 58.0 50.9 55.7 52.6

23,900 22,800 35,900 35,000 34,100 47,900 43,694 42,300 54,616

900 92095.7 96.3 96.7 98.7 96.7 97.7 99.2 99.7

77.0 79.0 77.0 77.5 79.0 79.5

-15~15-18~48

236 42 44 55 56 58 66 70 90 95 100

88.9 114.3 139.7

3~ / 50 / 400

258

EWAD-D-HS

EWAD380D-HS

MicroTech III

GC_pre2_lowres.pdf 258 30/11/2011 12:31:46

Page 261: DAIKIN General Catalogue 2012

259

GC_pre2_lowres.pdf 259 30/11/2011 12:31:46

Page 262: DAIKIN General Catalogue 2012

260

Standard efficiency

Cooling only Standard/low soundCapacity class 330 360 400 420 460 490 520Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight (SS) Unit kg

Operation weight kgWeight (SL) Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level (SS) Cooling Nom. dBASound power level (SL) Cooling Nom. dBASound pressure level (SS) Cooling Nom. dBASound pressure level (SL) Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet 168.3mmPower supply Phase / Frequency / Voltage Hz / V

› ESEER up to 4.70 (SS/SL) › High seasonal efficiency (ESEER up to 5.01) (XS/XL/XR) › All models are PED pressure vessel approved › Inverter stepless single-screw compressor › Optimised for use with R-134a › Cooling range: 329-515kW › 2 truly independent refrigerant circuits › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › The ability to vary the output power in direct relation to

the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up

› Standard electronic expansion valve › Partial and total heat recovery option available › Power factor over 0.95 › Standard operation range down to -10°C

Air cooled inverter chiller

260

329 358 395 423 459 488 515

13.5120.0 136 147 159 168 181 1932.74 2.63 2.69 2.66 2.73 2.70 2.674.59 4.60 4.55 4.59 4.57 4.70 4.602,355x2,234x4,381 2,355x2,234x5,281 2,355x2,234x6,181

4,190 4,590 4,9904,440 4,840 5,2404,340 4,740 5,1404,590 4,990 5,390

271 264 256 24815.72 17.10 18.87 20.21 21.93 23.32 24.61

60 61 72 67 78 69 76

32,667 40,833 49,000700

102.8 103.2 103.696.9 97.3 98.2

83.0 83.577.0 77.5

-9.5~15-10~45

73 99 105 114 118 121

2

3~ / 50 / 400

260

EWAD330,360BZ

PCO2

EWAD-BZSS/SL

GC_pre2_lowres.pdf 260 30/11/2011 12:31:47

Page 263: DAIKIN General Catalogue 2012

261

High efficiency

Cooling only Standard/low/reduced sound Capacity class 330 360 400 420 460 490 520Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight (XS) Unit kg

Operation weight kgWeight (XL) Unit kg

Operation weight kgWeight (XR) Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water fl ow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level (XS) Cooling Nom. dBASound pressure level (XS)

Cooling Nom. dBA

Sound power level (XL) Cooling Nom. dBASound pressure

level (XL)Cooling Nom. dBA

Sound power level (XR) Cooling Nom. dBASound pressure

level (XR)Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

261

329 358 395 423 459 488 515

13118.0 135 145 157 165 178 190

2.79 2.65 2.72 2.69 2.78 2.74 2.71

4.79 4.82 4.78 4.84 4.81 5.01 4.84

2,355x2,234x4,381 2,355x2,234x5,281 2,355x2,234x6,181

4,190 4,590 4,9904,440 4,840 5,2404,340 4,740 5,1404,590 4,990 5,3904,390 4,790 5,1904,640 5,040 5,440

271 264 256 24815.72 17.10 18.87 20.21 21.93 23.32 24.61

60 61 72 67 78 69 76

32,667 40,833 49,000700

102.8 103.2 103.6

83.0 83.5

96.9 97.3 98.2

77.0 77.5

92.9 93.3 94.2

73.0 73.5

-9.5~15-10~45

73 99 105 114 118 121

2168.3

3~ / 50 / 400

261

EWAD-BZXS/XL/XR

GC_pre2_lowres.pdf 261 30/11/2011 12:31:47

Page 264: DAIKIN General Catalogue 2012

262

650 740 830 910 970 C11 C12 C13 H14 C15 C16 C17 C18 C19 C20647 744 832 912 967 1,064 1,152 1,319 1,418 1,538 1,622 1,714 1,802 1,875 1,922

12.5 7221 262 299 318 351 378 402 441 474 551 580 618 665 682 714

2.93 2.84 2.78 2.87 2.76 2.82 2.86 2.99 2.79 2.8 2.77 2.71 2.75 2.69

3.95 3.87 3.89 3.84 3.8 3.88 3.84 4.08 4.07 3.9 3.87 3.78 3.79 3.81 3.77

2,540x2,285x6,1852,540x2,285

x7,0852,540x2,285

x7,985 2,540x2,285x8,885 2,540x2,285x11,085 2,540x2,285x11,985

5,630 5,740 5,760 6,280 6,560 7,010 7,280 7,900 10,320 10,710 10,770 11,240 11,6005,910 5,990 6,010 6,530 6,810 7,250 7,520 8,280 10,730 11,110 11,260 12,110 12,4805,920 6,030 6,050 6,570 6,850 7,300 7,570 8,190 10,770 11,150 11,210 11,680 12,0406,200 6,280 6,300 6,820 7,100 7,540 7,810 8,570 11,170 11,550 11,700 12,560 12,920

266 251 243 386 408 474 85030.9 35.56 39.74 43.6 46.21 50.85 55.04 62.9 67.7 73.5 77.51 81.89 86.00 89.50 91.7073 59 52 61 68 63 72 54 58 59 65 73 36 39 40

53,444 64,133 74,822 85,510 96,199 106,888 117,577 128,266

92099.5 100.0 100.9 101.1 101.5 101.7 101.9 103.0 103.2 103.3 103.5 103.779.0 79.5 80.4 80.6 80.7 81.1 81.2 81.5 81.996.0 96.1 97.5 97.1 97.6 98.1 98.2 99.1 99.5 99.9 101

75.5 75.6 76.5 76.6 76.8 76.9 77 77.2 77.3 77.4 77.9 78

-8~15-18~46

128 146 144 162 178 196 260 261 275 3052 3

168.3 219.13~/50/400

262

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight (SS) Unit kgOperation weight kg

Weight (SL) Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop Cooling Heat exchanger kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level (SS) Cooling Nom. dBASound pressure level (SS) Cooling Nom. dBASound power level (SL) Cooling Nom. dBASound pressure level (SL) Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/V

› Wide capacity range: 15 sizes to cover a range from 647 to 1,922 kW (SS/SL), 16 sizes from 619 to 1,833 kW (SR)

› Stepless single-screw compressor › Large operation range (ambient temperature

down to -18°C and up to 46°C) › Reduced sound version (SR) › All models are PED pressure vessel approved › Optimised for use with R-134a › 2-3 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Partial and total heat recovery option available › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Air cooled chiller, standard efficiency

Standard/low sound

262

EWAD-C15C-

EWAD-C-SS/SL

MicroTech III

GC_pre2_lowres.pdf 262 30/11/2011 12:31:47

Page 265: DAIKIN General Catalogue 2012

263

Cooling onlyCapacity class 620 720 790 880 920 C10 C11 C12 H14 C13 C14 C15 C14 C17 C18 C19Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water fl ow

Cooling l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

Reduced sound

263

619 715 789 876 922 1,020 1,112 1,270 1,321 1,367 1,471 1,556 1,623 1,714 1,795 1,833

12.5 7223 272 315 331 369 395 417 457 495 517 576 603 647 702 718 757

2.77 2.62 2.51 2.65 2.5 2.59 2.67 2.78 2.67 2.64 2.55 2.58 2.51 2.44 2.50 2.42

4.08 3.96 3.98 3.99 4 3.96 4.12 4.00 3.9 3.87 3.9 3.83 3.79 3.82 3.77

2,540x2,285x6,1852,540x2,285

x7,0852,540x2,285

x7,9852,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 2,540x2,285x11,985

5,920 6,030 6,050 6,750 6,850 7,300 7,570 8,190 10,750 10,770 11,150 11,210 11,680 12,0406,200 6,280 6,300 6,820 7,100 7,540 7,810 8,570 11,170 11,550 11,700 12,560 12,920

266 251 243 386 421 408 474 850

29.57 34.15 37.71 41.83 44.05 48.75 53.11 60.67 63.11 65.32 70.28 74.32 77.57 81.80 85.60 87.50

67 55 47 57 62 58 68 50 54 44 54 60 66 33 36 37

41,006 49,207 57,408 65,610 73,811 82,012 90,213 90,216 98,417715

91.5 92.0 92.5 93.0 93.5 93.8 94 94.8 94.9 95.1 95.2 95.5 95.9

71.0 71.5 72 72.5 72.6 72.7 72.9 73.0 73.1 73.4 73.7 74

-8 ~ 15-18 ~ 46

128 144 162 178 196 260 261 275 3052 3

168.3mm 219.1mm 273mm

3~ / 50 / 400

263

EWAD-C-SR

GC_pre2_lowres.pdf 263 30/11/2011 12:31:47

Page 266: DAIKIN General Catalogue 2012

264

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight (XS) Unit kgOperation weight kg

Weight (XL) Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop Cooling Heat exchanger kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/sFan motor Speed Cooling Nom. rpmSound power level (XS) Cooling Nom. dBASound pressure level (XS) Cooling Nom. dBASound power level (XL) Cooling Nom. dBASound pressure level (XL) Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/V

› Wide capacity range: 17 sizes to cover a range from 756 to 2,008 kW (XS/XL), from 736 to 1,959 kW (XR)

› Stepless single-screw compressor › Large operation range (ambient temperature

down to -18°C and up to 50°C) › All models are PED pressure vessel approved › Optimised for use with R-134a › 2-3 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Partial and total heat recovery option available › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Air cooled chiller, high efficiency

Standard/low sound

264

760 830 890 990 C10 C11 C12 C13 H14 H15 C16 C17 C18 C19 C20 C21 C22756 830 889 1,001 1,074 1,196 1,280 1,349 1,415 1,525 1,596 1,685 1,768 1,858 1,901 1,953 2,008

12.5 7233 253 278 307 338 364 400 411 444 475 504 533 561 590 615 642 672

3.25 3.28 3.2 3.26 3.18 3.29 3.2 3.29 3.19 3.21 3.17 3.16 3.15 3.09 3.04 2.99

4.02 4.11 4.02 4.11 4.05 4.14 4.02 4.28 4.31 4.35 4.17 4.16 4.13 4.12 4.03 4.01

2,540x2,285 x6,185

2,540x2,285 x7,085

2,540x2,285 x7,985 2,540x2,285x9,785 2,540x2,285

x11,9852,540x2,285 x12,885

2,540x2,285 x13,785 2,540x2,285x14,685

5,990 6,340 6,360 7,190 7,470 8,220 8,240 8,900 11,570 11,900 12,260 12,6006,240 6,580 6,600 7,600 7,870 8,610 8,630 9,890 12,430 12,760 13,140 13,4706,280 6,630 6,650 7,480 7,760 8,510 8,530 9,190 12,010 12,350 12,700 13,0406,520 6,870 6,890 7,880 8,160 8,900 8,920 10,180 12,870 13,200 13,580 13,910

251 243 403 386 979 850 871 85036.1 39.67 42.49 47.82 51.32 57.13 61.18 64.45 67.50 72.86 76.24 80.48 84.47 88.79 90.77 93.2 95.880 56 64 61 69 45 51 71 77 84 62 68 64 37 39 41 43

64,133 74,822 85,510 106,888 128,266 138,954 149,643 160,332920

100.2 100.5 101.4 101.9 102.4 102.5 103.2 103.5 103.7 103.979.7 80.2 80.7 80.3 80.4 80.9 80.8 81

96.8 97.4 98 98.2 98.8 98.9 99.6 100 100.2 100.476.3 76.5 76.9 77.1 76.7 76.8 77.3 77.4 77 77.5

-8~15-18~50

146 162 182 214 225 248 297 312 328 343 3432 3

168.3 219.1 2733~/50/400

264

EWAD-C11-C13C-

EWAD-C-XS/XL

MicroTech III

GC_pre2_lowres.pdf 264 30/11/2011 12:31:48

Page 267: DAIKIN General Catalogue 2012

265

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water fl ow Cooling l/sNominal water pressure drop Cooling Heat exchanger kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/V

Reduced sound

265

740 810 870 970 C10 C11 C12 C13 H14 H15 C16 C17 C18 C19 C20 C21 C22736 811 866 974 1,041 1,168 1,247 1,302 1,367 1,468 1,550 1,639 1,722 1,813 1,854 1,902 1,959

12.5 7235 254 281 309 343 365 404 415 454 491 513 541 567 595 624 658 692

3.14 3.2 3.08 3.15 3.03 3.2 3.08 3.14 3.01 2.99 3.03 3.04 2.97 2.89 2.83

4.29 4.36 4.23 4.34 4.24 4.38 4.25 4.33 4.38 4.43 4.26 4.2 4.21 4.2 4.1 4.08

2,540x2,285 x6,185

2,540x2,285 x7,085

2,540x2,285 x7,985 2,540x2,285x9,785 2,540x2,285

x11,9852,540x2,285 x12,885

2,540x2,285 x13,785 2,540x2,285x14,685

6,280 6,630 6,650 7,480 7,760 8,510 8,530 9,190 12,010 12,350 12,700 13,0406,520 6,870 6,890 7,880 8,160 8,900 8,920 10,180 12,870 13,200 13,580 13,910

251 243 403 386 979 850 871 85035.17 38.74 41.36 46.54 49.76 55.78 59.56 62.21 65.20 70.00 74.07 78.32 82.3 86.61 88.5 90.7 93.576 54 61 58 65 43 49 67 73 79 59 65 61 35 37 39 41

49,207 57,408 65,610 82,012 82,014 98,414 106,616 114,817 123,018 123,021

71592 92.3 93.5 93.7 94.3 94.5 94.4 94.6 95.3 95.6 95.7 95.9 96.2 96.6

71.5 72.3 72.5 72.2 72.3 72.5 72.9 73 73.3 73.7

-8~15-18~50

146 162 182 214 225 248 297 312 328 343 3432 3

168.3 219.1 2733~/50/400

265

EWAD-C-XR

GC_pre2_lowres.pdf 265 30/11/2011 12:31:48

Page 268: DAIKIN General Catalogue 2012

266

› Premium efficiency version (PS/PL) › Premium efficiency and reduced sound version (PR) › Wide capacity range: 9 sizes to cover a range from 821 to 1,562 kW (PS/PL),

from 809 to 1,521 kW (PR) › Stepless single-screw compressor › Large operation range (ambient temperature

down to -18°C and up to 52°C) › All models are PED pressure vessel approved › Optimised for use with R-134a › 2 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Partial and total heat recovery option available › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Air cooled chiller, premium efficiency

Cooling onlyCapacity class 820 890 980 C11 C12 C13 C14 C15 C16

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight (PS) Unit kgOperation weight kg

Weight (PL) Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level (PS) Cooling Nom. dBASound pressure

level (PS)Cooling Nom. dBA

Sound power level (PL) Cooling Nom. dBASound pressure

level (PL)Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase / Frequency / Voltage Hz / V

Standard/low sound

266

821 890 975 1,074 1,158 1,279 1,390 1,474 1,562

12.5225 249 274 301 330 363 396 424 453

3.64 3.58 3.56 3.51 3.52 3.51 3.48 3.45

4.44 4.5 4.41 4.53 4.39 4.44 4.31 4.33 4.32

2,540x2,285x8,885 2,540x2,285x9,7852,540x2,285

x11,0852,540x2,285x11,985

7,530 7,660 8,290 8,550 9,390 9,7308,130 8,700 9,330 9,590 10,380 10,7207,820 7,950 8,580 8,840 10,380 10,7208,420 8,990 9,620 9,880 10,670 11,010

599 1,043 1,027 995 97939.22 42.53 46.6 51.3 55.31 61.12 66.41 70.30 74.50

57 65 30 61 69 60 73 81 89

96,199 106,888 117,577 128,266 128,266

920101 101.8 102.3 102.6 102.9 103.2 103.5

79.5 80 80.5 80.4 80.5 80.8 81.1

98.4 98.8 99.9 99.3 99.6 99.9 100.2

76.9 77 77.1 77.2 77.5 77.8

-8 ~ 15-18 ~ 52

204 202 204 220 252 254

2219.1 273

3~ / 50 / 400

266

EWAD-C-

EWAD-C-PS/PL

MicroTech III

GC_pre2_lowres.pdf 266 30/11/2011 12:31:48

Page 269: DAIKIN General Catalogue 2012

267

Cooling onlyCapacity class 810 880 960 C10 C11 C13 C14 C15 C16

Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water fl ow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet mm

Power supply Phase / Frequency / Voltage Hz / V

Reduced sound

267

809 875 956 1,053 1,132 1,251 1,359 1,439 1,521

12.5219 244 272 299 330 364 396 425 457

3.7 3.58 3.51 3.52 3.43 3.44 3.43 3.39 3.33

4.63 4.59 4.54 4.59 4.5 4.53 4.51 4.50 4.45

2,540x2,285x8,885 2,540x2,285x9,7852,540x2,285x11,085

2,540x2,285x11,985

7,820 7,950 8,580 8,840 10,380 10,7208,420 8,990 9,620 9,880 10,670 11,010

599 1,043 1,027 995 97938.65 41.81 45.69 50.3 54.11 59.76 64.95 68.7 72.6

56 63 29 59 66 58 70 77 84

73,811 82,012 90,213 98,414 98,417715

92.7 93.4 93.8 94.1 94.4 94.7 9571.2 71.7 72.0 72.3 72.6

-8 ~ 15-18 ~ 52

204 202 204 220 252 254

2

219.1 273

3~ / 50 / 400

267

EWAD-C-PR

GC_pre2_lowres.pdf 267 30/11/2011 12:31:49

Page 270: DAIKIN General Catalogue 2012

268

Cooling onlyCapacity class

Cooling capacity Nom. kW

Capacity control Method Stepless

Minimum capacity %Power input Cooling Nom. kW

EER

ESEER

Dimensions Unit HeightxWidthxDepth mm

Weight (XS) Unit kg

Operation weight kg

Weight (XL) Unit kg

Operation weight kg

Water heat exchanger

Type Single pass shell & tube

Water volume l

Nominal water flow Cooling l/s

Nominal water pressure drop Cooling Heat exchanger kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcooler

Fan Air flow rate Nom. l/s

Fan motor Speed Cooling Nom. rpm

Sound power level (XS) Cooling Nom. dBA

Sound pressure level (XS) Cooling Nom. dBA

Sound power level (XL) Cooling Nom. dBA

Sound pressure level (XL) Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressor

Operation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDB

Refrigerant Type R-134a

Circuits Quantity

Refrigerant circuit Charge kg

Piping connections Evaporator water inlet/outlet mm

Power supply Phase/Frequency/Voltage Hz/V

› ESEER up to 5.76 (XS/XL), 5.79 (XR) › Inverter stepless single-screw compressor › High efficiency, standard and low sound levels › Optimised for use with R-134a › Wide operating range › Extensive option list (heat recovery option available) › Low starting current › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Air cooled inverter chiller,

high efficiency

Standard/low sound

268

670 740 830 900 C10 C11 C12 C13 C14 C15 C16 C17 C18

672 738 832 902 1,037 1,095 1,236 1,308 1,450 1,545 1,622 1,709 1,802

20 13

245 235 266 305 339 375 400 442 488 531 558 611

2.74 3.14 3.13 2.96 3.06 2.92 3.09 2.96 2.97 2.91 2.90 2.95

5.07 5.13 5.20 5.22 5.24 5.03 4.93 4.74 5.02 5.17 5.03 5.76 4.85

2,540x2,285x6,725 2,540x2,285x7,625 2,540x2,285x8,5252,540x2,285

x10,3252,540x2,285

x11,6252,540x2,285

x12,5252,540x2,285

x13,4252,540x2,285

x14,325

5,880 6,000 6,620 6,870 7,440 8,570 8,970 9,600 9,940 11,370 12,190 12,920

6,140 6,250 6,860 7,110 7,880 8,960 9,360 9,980 10,320 12,220 13,040 13,790

6,170 6,280 6,900 7,150 7,720 8,850 9,250 9,880 10,220 11,790 12,610 13,340

6,430 6,530 7,140 7,390 8,160 9,240 9,640 10,260 10,600 12,640 13,460 14,210

263 248 241 441 383 374 850 871

32.00 35.20 39.70 43.00 49.50 52.30 59.00 62.40 69.20 73.70 77.40 81.50 86.00

80 75 55 64 63 69 46 51 61 71 62 68 64

54,188 65,025 75,863 86,700 108,376 119,213 130,051 129,454 140,143 151,129

900

102.1 102.2 102.5 102.9 103.5 104.1 105.8 106.0 106.2

81.0 81.1 81.2 82.8 82.9

98.6 99.2 99.5 99.9 100.5 101.1 102.8 103.0 103.2

77.5 78.0 78.1 78.2 79.8 79.9

-8~15

-18~50

2 3

141 161 178 200 235 275 320 327 343 361

168.3 219.1 273

3~/50/400

268

EWAD-CZ

EWAD-CZXS/XL

MicroTech III

GC_pre2_lowres.pdf 268 30/11/2011 12:31:49

Page 271: DAIKIN General Catalogue 2012

269

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop Cooling Heat exchanger kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/sFan motor Speed Cooling Nom. rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Circuits QuantityRefrigerant circuit Charge kgPiping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/V

Reduced sound

269

640 700 790 850 980 C10 C11 C12 C13 C14 C15 C16 C17635 700 789 852 976 1,031 1,170 1,235 1,332 1,443 1,545 1,631 1,712

20 13260 242 271 314 347 388 408 455 524 589 580 610 631

2.44 2.89 2.91 2.71 2.81 2.65 2.86 2.71 2.55 2.45 2.66 2.67 2.71

5.52 5.71 5.76 5.79 5.49 5.41 5.05 5.45 5.60 5.51 5.33 5.19

2,540x2,285x6,725 2,540x2,285x7,625 2,540x2,285x8,5252,540x2,285

x10,3252,540x2,285 x11,625

2,540x2,285 x12,525

2,540x2,285 x13,425

2,540x2,285 x14,325

6,170 6,470 7,100 7,360 7,950 9,120 9,530 10,180 10,530 12,150 12,990 13,7406,430 6,720 7,340 7,600 8,390 9,500 9,920 10,550 10,910 13,000 13,840 14,610

263 248 241 441 383 374 850 871

30.30 33.40 37.60 40.70 46.60 49.20 55.80 58.9 63.60 68.80 73.70 77.80 81.7073 69 51 58 57 63 43 47 53 59 57 62 59

41,536 49,843 58,151 66,458 83,072 99,687 107,994 116,301

70094.6 95.2 95.5 95.9 96.5 97.1 98.8 99.0 99.273.5 74.0 74.1 74.2 75.8 75.9

-8~15-18~50

2 3141 161 178 200 235 275 320 327 343 361

168.3 219.1 2733~/50/400

269

EWAD-CZXR

GC_pre2_lowres.pdf 269 30/11/2011 12:31:49

Page 272: DAIKIN General Catalogue 2012

Cooling onlyCapacity classCooling capacity Nom. kW

Mechanical capacity kW

Capacity control Method SteplessMinimum capacity %

Power input Cooling Nom. kW

EER

ESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Asymm single screwOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/VAir temperature for free cooling 100% °C

(1) Cooling: evaporator 16/10°C, ambient 35°C, unit at full load operation; standard: ISO 3744 (2) Data is calculated at ambient air temperature 5°C, inlet water temperature 16°C.

› Free cooling chiller › High efficiency, standard/low (XS/XL) & reduced (XR) sound levels › Greater energy savings and reduced CO

2 emissions during cold season

› Wide capacity range: 11 sizes between 602 and 1,476 kW (XR), 640 and 1,555 kW (XS/XL)

› Wide operating range › MicroTech III controller

Air cooled free cooling chiller, high efficiency

Reduced sound600 740 820 870 980 C10 C11 C12 C13 C14 C15

602 (1) / 270 (2)

739 (1) / 334 (2)

821 (1) / 379 (2)

866 (1) / 409 (2)

981 (1) / 459 (2)

1,034 (1) / 492 (2)

1,229 (1) / 562 (2)

1,302 (1) / 598 (2)

1,374 (1) / 619 (2)

1,424 (1) / 640 (2)

1,476 (1) / 668 (2)

332 (2) 405 (2) 442 (2) 457 (2) 523 (2) 542 (2) 667 (2) 704 (2) 756 (2) 784 (2) 809 (2)

12.5263 (1) / 70.3 (2)

278 (1) / 84.3 (2)

299 (1) / 88.4 (2)

334 (1) / 95.9 (2)

368 (1) / 106 (2)

412 (1) / 112 (2)

403 (1) / 127 (2)

450 (1) / 141 (2)

466 (1) / 146 (2)

511 (1) / 154 (2)

556 (1) / 161 (2)

2.29 (1) / 8.56 (2)

2.66 (1) / 8.77 (2)

2.75 (1) / 9.29 (2)

2.59 (1) / 9.03 (2)

2.67 (1) / 9.27 (2)

2.51 (1) / 9.21 (2)

3.05 (1) / 9.67 (2)

2.90 (1) / 9.22 (2)

2.95 (1) / 9.4 (2)

2.79 (1) / 9.26 (2)

2.66 (1) / 9.15 (2)

3.59 3.66 3.89 3.62 3.83 3.63 4.13 3.89 4.09 4.02 3.922,565x2,480

x6,1852,565x2,480

x7,085 2,565x2,480x7,985 2,565x2,480x8,885 2,565x2,480x10,685

8,050 8,620 9,190 10,450 10,710 12,190 12,830 12,910 12,9608,320 8,870 9,430 10,850 11,110 12,580 13,820 13,900 13,950

266 251 243 403 386 97926.2 32.1 35.7 37.6 42.6 44.9 53.4 56.6 59.7 61.9 64.1

76 / 115 (2) 97 / 159 (2) 84 / 167 (2) 93 / 184 (2) 102 / 225 (2)

113 / 248 (2) 92 / 219 (2) 103 / 243

(2)128 / 282

(2)137 / 301

(2)146 / 321

(2)

38,934 46,721 54,508 62,294 73,010715

91.5 92.0 92.3 93.5 93.7 94.3 94.5 94.671.0 (1) 71.5 (1) 72.3 (1) 72.5 (1) 72.2 (1) 72.3 (1) 72.5 (1)

-8~15-20~45

128 146 162 182 214 225 2482

168.3 219.1 2733~/50/400

-2.3 -1.9 -0.6 -1.5 -0.9 -1.7 0.7 -0.2 -1.1 -1.6 -2.3

270

EWAD-CF

MicroTech III

EWAD-CFXR

GC_pre2_lowres.pdf 270 30/11/2011 12:31:50

Page 273: DAIKIN General Catalogue 2012

Cooling onlyCapacity classCooling capacity Nom. kW

Mechanical capacity kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kW

EER

ESEERDimensions Unit HeightxWidthxDepth mm

Weight (XS) Unit kgOperation weight kg

Weight (XS) Unit kgOperation weight kg

Water heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow Cooling l/sNominal water pressure drop

Cooling Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Nom. l/s

Speed rpmSound power level (XS) Cooling Nom. dBASound pressure level (XS) Cooling Nom. dBASound power level (XL) Cooling Nom. dBASound pressure level (XL) Cooling Nom. dBACompressor Type Asymm single screwOperation range Water side Cooling Min.~Max. °CDB

Air side Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping connections Evaporator water inlet/outlet mmPower supply Phase/Frequency/Voltage Hz/VAir temperature for free cooling 100% °C

(1) Cooling: evaporator 16/10°C, ambient 35°C, unit at full load operation; standard: ISO 3744 (2) Data is calculated at ambient air temperature 5°C, inlet water temperature 16°C.

Standard/low sound640 770 850 900 C10 C11 C12 C13 C14 C15 C16

640 (1) / 295 (2)

772 (1) / 365 (2)

852 (1) / 413 (2)

902 (1) / 434 (2)

1,027 (1) / 502 (2)

1,089 (1) / 524 (2)

1,269 (1) / 594 (2)

1,349 (1) / 652 (2)

1,435 (1) / 663 (2)

1,493 (1) / 659 (2)

1,555 (1) / 722 (2)

345 (2) 407 (2) 439 (2) 468 (2) 524 (2) 565 (2) 675 (2) 697 (2) 772 (2) 834 (2)

12.5257 (1) / 74.3 (2)

272 (1) / 87.9 (2)

293 (1) / 90.7 (2)

324 (1) / 99.8 (2)

360 (1) / 109 (2)

399 (1) / 118 (2)

397 (1) / 131 (2)

439 (1) / 143 (2)

454 (1) / 152 (2)

492 (1) / 160 (2)

530 (1) / 170 (2)

2.49 (1) / 8.62 (2)

2.84 (1) / 8.78 (2)

2.90 (1) / 9.4 (2)

2.78 (1) / 9.04 (2)

2.85 (1) / 9.43 (2)

2.73 (1) / 9.19 (2)

3.19 (1) / 9.67 (2)

3.08 (1) / 9.45 (2)

3.16 (1) / 9.42 (2)

3.04 (1) / 9.33 (2)

2.93 (1) / 9.16 (2)

3.44 3.52 3.78 3.50 3.74 3.54 3.88 3.78 4.01 3.95 3.852,565x2,480

x6,1852,565x2,480

x7,0852,565x2,480x7,985 2,565x2,480x8,885 2,565x2,480x10,685

7,760 8,340 8,900 10,160 10,420 11,900 12,540 12,620 12,6708,040 8,580 9,140 10,560 10,820 12,290 13,530 13,610 13,6608,050 8,620 9,190 10,450 10,710 12,190 12,830 12,910 12,9608,320 8,870 9,430 10,850 11,110 12,580 13,820 13,900 13,950

266 251 243 403 386 97927.8 33.5 37.0 39.2 44.6 47.3 55.1 58.6 62.4 64.9 67.6

85 / 128 (2)105 / 172

(2)90 / 178 (2)

101 / 198

(2)111 / 245

(2)124 / 272

(2)98 / 232 (2)

110 / 259

(2)139 / 305

(2)150 / 328

(2)162 / 354

(2)

50,367 60,440 70,513 80,587 95,253920

99.5 100.2 100.5 101.4 101.9 102.4 102.579.0 (1) 79.7 (1) 80.2 (1) 80.7 (1) 80.3 (1) 80.4 (1)96.0 96.8 97.4 98.0 98.2 98.8 98.9

75.5 (1) 76.3 (1) 76.5 (1) 76.9 (1) 77.1 (1) 76.7 (1) 76.8 (1)

-8~15-20~45

128 146 162 182 214 225 2482

168.3 219.1 2733~/50/400

-0.8 -0.1 1.2 0.4 0.9 0.1 2.9 2.1 1.3 0.7 0.1

271

EWAD-CFXS/XL

GC_pre2_lowres.pdf 271 30/11/2011 12:31:50

Page 274: DAIKIN General Catalogue 2012

272

Air cooled mini chiller inverter

› Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.57), significant reduction of starting currents ; precise temperature control (evaporator leaving water)

› Low operating sound level › Easy ‘plug and play’ installation › Daikin swing (sizes 005-006-007) or scroll compressor (sizes 009-010-011) › Integrated hydronics › Available options: evaporator heater type (OP10)

and high ESP pump up to 90 kPa (OPHP) › Single phase power supply and main switch included › Wide operating range

Heating & CoolingCapacity class 005 006 007 009 010 011

Cooling capacity Nom. kWHeating capacity Nom. kWPower input Cooling Nom. kW

Heating Nom. kWEERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow

Cooling l/minHeating l/min

Air heat exchanger Type Tube type Hi-XSS

Pump Nominal ESP unit Cooling kPaHydraulic components Expansion vessel Volume l

Fan Air flow rate Cooling Nom. m³/minHeating Nom. m³/min

Fan motor Speed Cooling Nom. rpmHeating Nom. rpmSteps

Sound power level Cooling Nom. dBAHeating Nom. dBA

Sound pressure

level

Cooling Nom. dBAHeating Nom. dBANight quiet mode

Cooling dBAHeating dBA

Compressor Type Hermetically sealed swing compressor Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Water circuit Piping connections diameter inch G 5/4" (female)Piping inch

Piping

connectionsWater heat exchanger inlet / outletWater heat exchanger drain Hose nipple 1/2" FBSP

Power supply Phase / Frequency / Voltage Hz / V

Digital controller

272

5.2 6.0 7.1 8.5 9.5 11.0

5.65 6.35 7.75 10.0 11.5 13.01.89 2.35 2.95 2.74 3.19 3.821.97 2.24 2.83 2.91 3.38 3.86

2.75 2.55 2.41 4.37 2.98 2.882.87 2.83 2.74 3.44 3.40 3.37

- 4.57 4.52 4.46

805x1,190x360 1,435x1,418x382100 180104 -

- 1.01

14.9 17.2 20.4 24.4 27.2 31.5

17.5 19.5 23.5 28.7 33.0 37.3

49.4 45.1 38.3 58.0 54.6 49.16 10- 96 100 97- 90- 780- 760- 8

62 63 64

- 64

48 50 51

48 49 51

- 45- 42

5~20 5~2225~50 25~50

10~43 10~46

-15~25 -15~35

1.7 2.95

1

-

- 5/4"

1" MBSP -

-

1~ / 50 / 230

272

EWYQ-ACV3

EWYQ005-011ACV3

GC_pre2_lowres.pdf 272 30/11/2011 12:31:50

Page 275: DAIKIN General Catalogue 2012

273

Heating & CoolingCapacity class 009 011 013Cooling capacity Nom. kWHeating capacity Nom. kWPower input Cooling Nom. kW

Heating Nom. kWEERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow

Cooling l/minHeating l/min

Air heat exchanger Type Hi-XSSPump Nominal ESP unit Cooling kPaHydraulic components Expansion vessel Volume l

Fan motor Speed Cooling Nom. rpmHeating Nom. rpmSteps

Sound power level Cooling Nom. dBAHeating Nom. dBA

Sound pressure

level

Cooling Nom. dBAHeating Nom. dBANight quiet mode

Cooling dBAHeating dBA

Compressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valveCircuits Quantity

Water circuit Piping connections diameter inch G 5/4" (female)Piping inch

Power supply Phase / Frequency / Voltage Hz / V

Air cooled mini chiller inverter

› Inverter technology ensures: continuous match of requested load, excellent part load efficiency (ESEER up to 4.68), significant reduction of starting currents, precise temperature control (evaporator leaving water)

› Low operating sound level › Easy ‘plug and play’ installation › Daikin scroll compressor › Integrated hydronics › Three phase power supply and main switch included › Wide operating range

Digital controller

273

9.0 11.0 13.211.0 12.5 14.02.96 3.82 5.10

3.23 3.70 4.19

3.04 2.88 2.59

3.41 3.38 3.34

4.68 4.63 4.521,435x1,418x382

180

1.01

25.8 31.5 37.8

31.5 35.8 40.1

56.4 49.1 40.9107807608

64 66

64

51 52

51

45 46

42 43

5~2225~50

10~46

-15~35

2.95

1

5/4"

3N~ / 50 / 400

273

EWYQ-ACW1

EWYQ009ACW1

GC_pre2_lowres.pdf 273 30/11/2011 12:31:50

Page 276: DAIKIN General Catalogue 2012

274

Heating & CoolingCapacity class N5 P5 B5 N8 P8 B8 N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24

Cooling capacity Nom. kWHeating capacity Nom. kWCapacity steps %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plateWater volume l

Nominal water flow

Cooling l/minHeating l/min

Nominal water pressure drop

Cooling Filter kPaHeating Filter kPa

Air heat exchanger Type Cross fin coil/Hi-X tubes and PE coated waffle louvre finsHydraulic components Expansion vessel Volume l

Fan group Air flow rate Cooling Nom. m³/min 160 (per 2 fans) 170 (per 2 fans)Fan group 2 Air flow rate Cooling Nom. m³/min 170 (per 2 fans)Sound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDBRefrigerant Type R-407C

Control Thermostatic expansion valveCircuits Quantity

Refrigerant circuit Charge kgRefrigerant circuit 2 Charge kgWater circuit Piping connections diameter inch G 1"1/4 (male) 2" male

Piping inchPower supply Phase / Frequency / Voltage Hz / V

› Optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to integrated pump and/or buffer tank › Possibility for a 200l buffer tank › Low operating sound level › Easy maintenance › Main switch › Water flow switch › 3 different design options available:

- EUWYN chiller without integrated hydraulic module;- EUWYP chiller with integrated hydraulic module (pump,

expansion vessel, hydraulic components); - EUWYB chiller with integrated hydraulic module (buffer

tank, pump, expansion vessel, hydraulic components)

› μC² SE controller

Air cooled chiller

274

9.1 17.1 21.0 25.0 34.2 40 50.011.9 18.5 24.0 27.0 37.0 46 54.0

0-100 0-50-1003.77 7.38 8.49 11.3 14.8 16.2 22.64.56 7.01 8.98 10.7 14.10 17.3 21.42.41 2.32 2.47 2.21 2.3 2.5 2.22.61 2.64 2.67 2.52 2.62 2.66 2.52

1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734

163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546

165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612

1.140 1.615 1.900 2.375 2.964 3.900 4.524

26 49 60 72 98 115 14334 53 69 77 106 132 15510 25 24 33 12 1917 29 31 38 14 16 22

- 12 - 12 - 12 - 12 - 12 - 12 - 12

-

67 76 78 79 81

-10(OPZL) ~ 2035 ~ 50-15 ~ 43 -10 ~ 21

1 24.6 4.7 5.4 5.1 5.4 5.6

- 5.1 5.4 5.6

1-1/4" 2"

3N~ / 50 / 400

274

EUWY*16KBZW1

EUWY(N-P-B)-KBZW1

μC² SE

GC_pre2_lowres.pdf 274 30/11/2011 12:31:51

Page 277: DAIKIN General Catalogue 2012

275

Heating & CoolingCapacity class

Cooling capacity Nom. kW

Heating capacity Nom. kW

Capacity control Method Inverter controlled

Minimum capacity %Power input Cooling Nom. kW

Heating Nom. kW

EER

ESEER

COP

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation weight kg

Water heat

exchanger

Type Brazed plate

Water volume l

Nominal water

flow

Cooling l/min

Heating l/min

Nominal water pressure drop Cooling Total kPa

Air heat exchanger Type Hi-XSS

Fan Air flow rate Cooling Nom. m³/min

Heating Nom. m³/min

Sound power level Cooling Nom. dBA

Compressor Type Hermetically sealed scroll compressor

Operation range Water side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDB

Air side Cooling Min.~Max. °CDB

Heating Min.~Max. °CDB

Refrigerant Type R-410A

Charge kg

Control Electronic expansion valve

Circuits Quantity

Water circuit Piping inch

Power supply Phase/Frequency/Voltage Hz/V

Air cooled heat pump inverter chiller

› High efficiency chiller with leader-of-class ESEER (up to 4.75) › Minimal starting currents and short payback times › No buffertank required for standard applications › Naked or with factory mounted (standard/high-ESP) pump › Low sound thanks to inverter compressor / fans › EWYQ-BAWN: Naked › EWYQ-BAWP: With pump

275

016 021 025 032 040 050 064

16.8 21.0 25.2 31.5 42.0 50.4 63.0

16.8 21.0 25.2 31.5 42.0 50.4 63.0

25

5.57 7.25 9.25 12.9 14.9 19.0 26.7

5.51 7.09 8.87 10.5 14.2 17.8 21.0

3.01 2.90 2.72 2.44 2.82 2.65 2.36

4.75 4.65 4.45 4.00 4.60 4.40 3.95

3.05 2.96 2.84 3.00 2.96 2.83 3.00

1,684x1,371x774 1,684x1,684x774 1,684x2,358x780 1,684x2,980x780

264 317 397 571 730

267 320 401 577 738

1 2 3 5

48 60 72 90 120 144 181

48 60 72 90 120 144 181

20 30 42 30 42 30

171 185 233 370 466.0

171 185 233 370 466

78 80 81 83

5~20

25~50

-5~43

-15~35

7.6 9.6 15.2 19.2

1

1-1/4” 1-1/2"3N~/50/400

275

EWYQ-BA*

EWYQ-BAWN/BAWP

BRC21A52

GC_pre2_lowres.pdf 275 30/11/2011 12:31:51

Page 278: DAIKIN General Catalogue 2012

276

Heating & CoolingCapacity class 080 100 130 150 180 210 230 250Cooling capacity Nom. kWHeating capacity Nom. kWCapacity steps %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Brazed plate, one per unitNominal water flow

Cooling l/minHeating l/min

Nominal water pressure drop

Cooling Total kPaHeating Total kPa

Air heat exchanger Type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsFan Air flow rate Nom. m³/min

Speed rpmSound power level Cooling Nom. dBACompressor Type Scroll compressorOperation range Water side Cooling Min.~Max. °CDB

Water side Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDBAir side Heating Min.~Max. °CDB

Refrigerant Type R-410AControl Electronic expansion valveCircuits Quantity

Refrigerant circuit Charge kgRefrigerant circuit 2 Charge kgPiping

connectionsWater heat exchanger inlet / outletWater heat exchanger drain

Power supply Phase / Frequency / Voltage Hz / V

Air cooled chiller, multiple scroll

› Optimised for use with R-410A refrigerant › Multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › Low operating sound level › Easy 'plug and play' installation › Fans protected against abnormal operation (4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from 3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent refrigerant circuits (EWYQ130-250DAYN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin Pcaso controller with user friendly and powerful LCD interface

276

77 100 136 145 183 211 231 25287.7 114 149 165 199 225.00 258 281

0-50-100 0-25-50-75-10021/29-

43/50/57-

71/79-1000-25-50-75-100

22/28-

44/50/56-

72/78-1000-25-50-75-100

26.5 36.2 47.6 55.7 63.8 75.3 82.2 93.530.0 38.1 49.6 58.8 68.0 77.0 84.2 96.62.91 2.76 2.86 2.60 2.87 2.80 2.81 2.702.92 2.99 3.00 2.81 2.93 2.92 3.06 2.91

4.00 3.81 4.31 4.07 4.33 4.23 4.20 4.002,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850

1,400 1,450 1,550 1,600 1,850 1,900 3,200 3,3001,415 1,465 1,567 1,619 1,875 1,927 3,239 3,342

221 287 390 416 525 605 662 722251 327 427 473 570 645 740 806

36 43 38 41 44 39 3847 46 51 49 48 50 48 46

780 800 860 1,290 1,600880 900 970 90086 88 89 90 91

-10 (OPZL) ~ 2525 ~ 50-15 ~ 43-10 ~ 21

1 233 37 22 32 39

- 22 32 393" OD 3"

1/2"G

3~ / 50 / 400

276

EWYQ-DAYN

EWYQ130-150DAYN

PCASO

GC_pre2_lowres.pdf 276 30/11/2011 12:31:51

Page 279: DAIKIN General Catalogue 2012

277

Heating & CoolingCapacity class 250 270 290 320 340 370 380 410 440 460 510 520 580Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water fl ow

Cooling l/sHeating l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Heating Heat exchanger

kPa

Air heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/s

Speed rpmSound power level Cooling Nom. dBA

Heating Nom. dBASound pressure level Cooling Nom. dBA

Heating Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Water side Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDBAir side Heating Min.~Max. °CDB

Refrigerant Type R-134aCharge kgCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

› Optimised for use with R-134a › Cooling range: 254-583kW › Heating range: 270-615kW › EER range up to 2.83 › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Low starting current › No gas boiler required › Optimised defrost cycles › Optimum ESEER values › Partial and total heat recovery option available › PID microprocessor control › Power factor up to 0.95 › 2-3 truly independent refrigerant circuits › Standard operation range down to -10°C

Air cooled heat pump inverter chiller, standard efficiency, standard sound

277

254 273 292 324 339 365 382 413 436 457 505 522 583270 297 324 333 349 379 410 443 463 475 530 558 615

13 990.3 100 109 116 124 134 142 152 163 161 178 186 21590.4 99 107 117 124 132 141 155 165 164 176 184 2052.81 2.74 2.69 2.79 2.74 2.73 2.68 2.72 2.68 2.83 2.83 2.81 2.71

2.98 2.99 3.03 2.84 2.80 2.87 2.90 2.85 2.81 2.90 3.02 3.04 3.004.05 4.04 4.01 4.07 4.01 4.02 3.94 4.03 4.01 4.31 4.13 4.05

2,335x2,254x3,547 2,335x2,254x4,381 2,335x2,254x5,281 2,335x2,254x6,5833,410 3,455 3,500 3,870 3,940 4,010 4,390 5,015 5,495 5,7353,550 3,595 3,640 4,010 4,068 4,138 4,518 5,255 5,724 5,964 5,953

138 133 128 240 229 21812.12 13.03 13.94 15.46 16.21 17.42 18.25 19.72 20.81 21.83 24.11 24.92 27.8712.89 14.18 15.49 15.89 16.66 18.11 19.57 21.15 22.14 22.68 25.33 26.65 29.39

37 42 48 53 58 53 57 46 51 61 50 53 65

42 49 58 55 60 57 65 52 57 66 55 60 71

31,728 42,304 52,880 63,456

920100.5 101.2 101.8 103.6100.5 101.2 101.8 103.682.1 82.3 82.5 83.7

82.1 82.3 82.5 83.7

-8~1535~55-10~45-10~20

88 94 100 118 121 124 148 177 183 186

2 3139.7 219.1mm

3~ / 50 / 400

277

EWYD250BZSS

EWYD-BZSS

PCO2

GC_pre2_lowres.pdf 277 30/11/2011 12:31:52

Page 280: DAIKIN General Catalogue 2012

278

Heating & CoolingCapacity class 250 270 290 320 330 360 370 400 430 450 490 510 570Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger

Type Single pass shell & tubeWater volume l

Nominal water flow

Cooling l/sHeating l/s

Nominal water pressure drop

Cooling Heat exchanger

kPa

Heating Heat exchanger

kPa

Air heat exchanger Type High efficiency fin and tube type with integral subcoolerFan Air flow rate Cooling Nom. l/s

Heating Nom. l/sFan motor Speed Cooling Nom. rpm

Heating Nom. rpmSound power level Cooling Nom. dBA

Heating Nom. dBASound pressure

level

Cooling Nom. dBAHeating Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Water side Cooling Min.~Max. °CDB

Water side Heating Min.~Max. °CDBAir side Cooling Min.~Max. °CDBAir side Heating Min.~Max. °CDB

Refrigerant Type R-134aCharge kgCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

› Optimised for use with R-134a › Cooling range: 248-567kW › Heating range: 270-615kW › EER range up to 2.87 › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Low operating sound level › Low starting current › No gas boiler required › Optimised defrost cycles › Optimum ESEER values › Partial and total heat recovery option available › PID microprocessor control › Power factor up to 0.95 › 2-3 truly independent refrigerant circuits › Standard operation range down to -10°C

Air cooled heat pump inverter chiller, standard efficiency, low sound

278

248 266 291 316 331 355 372 403 425 448 493 510 567

270 297 324 333 349 379 410 443 463 475 530 558 615

13 988.5 98 109 113 122 132 142 149 161 156 174 183 214

90.4 99 107 117 124 132 141 155 165 164 176 184 205

2.80 2.70 2.66 2.79 2.72 2.68 2.62 2.71 2.64 2.87 2.83 2.79 2.65

2.98 2.99 3.03 2.84 2.80 2.87 2.90 2.85 2.81 2.90 3.02 3.04 3.004.18 4.16 4.11 4.29 4.18 4.16 4.13 4.19 4.14 4.31 4.29 4.23 4.10

2,335x2,254x3,547 2,335x2,254x4,381 2,335x2,254x5,281 2,335x2,254x6,5833,750 3,795 3,840 4,210 4,280 4,350 4,730 5,525 6,005 6,2453,888 3,933 3,978 4,343 4,408 4,478 4,858 5,765 6,234 6,474 6,463

138 133 128 240 229 21811.83 12.70 13.89 15.12 15.83 16.98 17.77 19.28 20.30 21.39 23.56 24.34 27.11

12.89 14.18 15.49 15.89 16.66 18.11 19.57 21.15 22.14 22.68 25.33 26.65 29.39

36 40 48 51 55 50 55 44 48 59 48 51 62

42 49 58 55 60 57 65 52 57 66 55 60 71

24,432 32,576 40,720 48,864

31,728 42,304 52,880 63,456

715920

94.0 94.7 95.3 97.094.9 96.1 96.7 98.475.6 75.8 76.0 77.276.5 77.2 77.4 78.6

-8~1535~55-10~45 -10~20

88 94 100 118 121 124 148 177 183 186

2 3139.7 219.1mm

3 ~/ 50 / 400

278

EWYD250BZSL

EWYD-BZSL

PCO2

GC_pre2_lowres.pdf 278 30/11/2011 12:31:52

Page 281: DAIKIN General Catalogue 2012

279

Cooling onlyCapacity class 120 140 170 200 220 250 310 370 440 490Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgAir heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/sFan motor Speed Cooling Nom. rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Saturated suction temp. Min-Max °C

Condenser Min-Max °CRefrigerant Type R-134a

Charge kgCircuits Quantity

Power supply Phase / Frequency / Voltage Hz / V

Air cooled condensing unit,standard efficiency, standard sound

› Wide capacity range (121 kW - 488 kW) › Single refrigerant circuit with single screw compressor › Compact design › Large operation range

(ambient temperature down to -18°C)

279

121 144 165 196 219 252 306 370 435 488

2541.8 51.0 57.4 65.2 73.7 76.6 92.8 122.0 147.2 160.8

2.90 2.83 2.87 3.00 2.97 3.28 3.30 3.04 2.96 3.03

2,273x1,292x2,165 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,0701,584 1,741 1,936 2,6791,617 1,781 1,981 2,756

10,922 10,575 16,383 15,863 21,844 21,150 32,767 31,725920

91.5 92.3 93.0 94.2 94.5 95.2

73.5 73.7 73.9 75.1 75.0 75.3 76.0

-9~12-18~48

17 20 22 27 29 32 45 54 581

3~ / 50 / 400

279

ERAD-E-SS

ERAD170,200E-SS

MicroTech III

GC_pre2_lowres.pdf 279 30/11/2011 12:31:52

Page 282: DAIKIN General Catalogue 2012

280

Cooling onlyCapacity class 120 140 160 190 210 240 300 350 410 460Cooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgAir heat exchanger Type High effi ciency fi n and tube type with integral subcoolerFan Air fl ow rate Nom. l/sFan motor Speed Cooling Nom. rpmSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Saturated suction temp. Min-Max °C

Condenser Min-Max °CRefrigerant Type R-134a

Charge kgCircuits Quantity

Power supply Phase / Frequency / Voltage Hz / V

Air cooled condensing unit,standard efficiency, low sound

› Low operating sound level › Wide capacity range (116 kW - 462 kW) › Single refrigerant circuit with single screw compressor › Compact design › Large operation range

(ambient temperature down to -18°C)

280

116 137 159 187 209 243 295 352 409 462

2542.3 52.5 57.6 66.3 73.9 78.2 91.5 122 150 167

2.74 2.61 2.75 2.82 2.83 3.11 3.23 2.88 2.73 2.76

2,273x1,292x2,165 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,0701,684 1,841 2,036 2,7891,717 1,881 2,081 2,886

8,372 8,144 12,558 12,217 16,744 16,289 25,117 24,433715

89.0 89.8 90.5 91.7 92.0 92.7

71.0 71.2 71.4 72.6 72.5 72.8 73.5

-9~12-18~48

17 20 22 27 29 32 45 54 581

3~ / 50 / 400

280

ERAD-E-SL

ERAD160,190E-SL

MicroTech III

GC_pre2_lowres.pdf 280 30/11/2011 12:31:53

Page 283: DAIKIN General Catalogue 2012

281

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger - evaporator

Type Shell and tubeWater volume l

Nominal water pressure drop Cooling Heat exchanger kPaWater heat exchanger - condenser

Type Shell and tubeWater flow rate Nom. l/sNominal water pressure drop Cooling kPaNominal water pressure drop 2 Cooling kPa

Sound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-410A

Control

Circuits QuantityRefrigerant circuit Charge kgRefrigerant circuit 2 Charge kgPiping

connectionsEvaporator water inlet/outlet mmCondenser water inlet/outlet inch

Power supply Phase/Frequency/Voltage Hz/V

› All models are PED pressure vessel approved › 1 or 2 stepless single-screw compressors › 1 or 2 truly independent refrigerant circuits › Shell and tube heat exchanger › Optimised for use with R-410A › Standard electronic expansion valve › Compact design › Partial heat recovery available › MicroTech III controller

Water cooled chiller, standard efficiency, standard sound

281

380 460 560 640 730 800 860 870 960 C10 C11 C12 C13 C14 C15 C17 C19 C20380 464 562 637 727 796 862 872 960 1,007 1,055 1,185 1,255 1,325 1,460 1,748 1,888 2,050

25 12.585.6 104 128 144 166 172 202 190 209 240 232 256 274 290 333 401 432 466

4.44 4.46 4.40 4.41 4.37 4.64 4.26 4.59 4.60 4.19 4.55 4.62 4.59 4.56 4.38 4.36 4.37 4.40

5.16 5.21 5.22 4.95 5.64 4.83 5.63 5.59 4.76 5.6 5.61 5.62 5.55 5.18 5.06 5.11 5.07

1,849x1,140 x3,373

2,001x1,276 x3,454

1,848x1,314 x3,535

2,158x1,350 x5,020

1,848x1,314 x2,001

2,158x1,350 x5,020

1,848x1,314 x2,001

2,378x1,350 x4,894

2,455x1,350x5,070 2,495x1,350 x4,892

2,495x1,350 x4,865

1,933 1,967 2,283 2,332 2,407 3,921 2,427 3,949 3,988 2,457 4,344 4,529 4,536 4,607 4,988 5,053 5,204 5,2892,135 2,169 2,543 2,628 2,777 4,422 2,795 4,463 4,496 2,812 4,780 5,186 5,200 5,280 5,602 5,670 5,881 5,970

124 118 176 170 274 344 266 344 325 251 325 538 505 495 539 52747 63 43 46 53 52 48 62 57 55 67 43 48 53 58 86 95 119

22.2 27.2 32.9 37.3 42.7 23.1 50.9 23.4 27.9 59.6 27.6 34.3 33.4 38.4 42.6 51 50.8 59.858 62 66 63 15 62 19 62 65 25 65 70 67 16 14

- 62 - 65 - 67 70 67 16 14

100.2 101.2 102.3 101.5 104.7 102.3 104.7 105.1 103.2 104.7 105.2 106.5 105.8 106.6 107.1 107.582.2 83.0 83.9 83.2 84 84.9 85.2 85 85.6 86 86.5 86.9 86.2 87.0 87.5 87.9

-4~1025~45

-

1 2 1 280 90 80 90 85 100 95 100 130

- 80 - 90 85 100 95 100 130152.4 203.25 6 5

3~/50/400

281

EWWQ-B-

EWWQ-B-SS

MicroTech III

GC_pre2_lowres.pdf 281 30/11/2011 12:31:53

Page 284: DAIKIN General Catalogue 2012

282

Cooling onlyCapacity classCooling capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWEERESEERDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger - evaporator

Type Shell and tubeWater volume l

Nominal water pressure drop Cooling Heat exchanger kPaWater heat exchanger - condenser

Type Shell and tubeWater flow rate Nom. l/sNominal water pressure drop Cooling kPaNominal water pressure drop 2 Cooling kPa

Sound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-410A

Control

Circuits QuantityRefrigerant circuit Charge kgRefrigerant circuit 2 Charge kgPiping

connectionsEvaporator water inlet/outlet mmCondenser water inlet/outlet inch

Power supply Phase/Frequency/Voltage Hz/V

› High efficiency

› All models are PED pressure vessel approved › 1 or 2 stepless single-screw compressors › 1 or 2 truly independent refrigerant circuits › Shell and tube heat exchanger › Optimised for use with R-410A › Standard electronic expansion valve › Compact design › Partial heat recovery available › MicroTech III controller

Water cooled chiller, high efficiency, standard sound

282

420 520 640 730 800 970 C10 C11 C12 C13 C14 C15 C16 C17 C19 C20 C21

422 516 639 725 801 973 1,037 1,116 1,158 1,270 1,369 1,449 1,573 1,733 1,863 2,020 2,152

25 12.5 25 12.584.9 102 126 143 159 193 205 227 228 252 269 286 315 349 382 417 451

4.97 5.03 5.09 5.07 5.05 5.06 4.91 5.07 5.04 5.08 5.07 4.99 4.96 4.87 4.84 4.77

5.86 5.88 5.97 5.95 5.89 5.66 6.18 5.54 6.13 6.28 6.23 5.92 6 5.73 5.78 5.64

2,001x1,276x3,863 2,001x1,268 x3,878

2,003x1,314 x3,878

2,003x1,446 x3,919

2,454x1,350 x5,219

2,003x1,446 x3,919 2,454x1,350x5,219 2,495x1,350x4,829 2,495x1,350

x4,865

2,322 2,403 2,464 2,738 2,407 2,427 4,775 2,457 4,831 4,873 4,919 4,969 5,117 5,388 5,408 5,414

2,594 2,685 2,745 3,158 2,815 3,056 5,431 3,086 5,479 5,512 5,546 5,606 5,794 5,843 6,110 6,118 6,124

220 213 200 334 325 538 587 538 575 563 551 495 484 535 52757 70 73 65 58 55 70 65 56 68 76 71 91 93 115 129

24.2 29.5 36.5 41.4 45.8 55.7 29.5 64.2 29.6 36.3 36.7 41.2 44.9 44.6 53.3 53.2 61.950 40 41 46 60 64 39 84 35 48 49 46 43 60 52 78

- 39 - 48 46 43 62 60 79 78100.9 101.7 102.6 102.7 102.0 102.9 105.2 103.8 105.6 106.1 106.5 105.8 106.2 106.6 107.1 107.582.2 83.0 83.9 83.2 84.0 85.6 84.9 86.0 86.5 86.9 86.2 86.6 87.0 87.5 87.9

-4~1025~45

-

1 2 1 295 110 130 120 130 120 130

- 120 - 120 130152.2 203.2 254 203.2 254 203.2 254

8 6 5 6 5 6 83~/50/400

282

EWWQ-B-

EWWQ-B-XS

MicroTech III

GC_pre2_lowres.pdf 282 30/11/2011 12:31:53

Page 285: DAIKIN General Catalogue 2012

283

Heating only & Cooling onlyCapacity class 014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 195Cooling capacity Nom. kWHeating capacity Nom. kWCapacity steps numberPower input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater heat exchanger - evaporator

Type Brazed plateMinimum water volume in the system l

Water fl ow rate Min. l/minNom. l/minMax. l/min

Water heat exchanger - condenser

Type Brazed plateWater fl ow rate Min. l/min

Nom. l/minMax. l/min

Sound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-407C

Control Thermostatic expansion valveCircuits Quantity

Refrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet FBSP 25mm FBSP 40mm 2 x 2 x FBSP 38mm 3 x 2 x FBSP 38mmEvaporator water drain Field installationCondenser water inlet/outlet FBSP 25mm FBSP 40mm 2 x 2 x FBSP 38mm 3 x 2 x FBSP 38mmCondenser water drain Field installation

Power supply Phase / Frequency / Voltage Hz / V

› Standard integrated: main switch, water fi lter, fl ow switch, air purge, pressure ports

› Daikin scroll compressor › Optimised for use with R-407C › Low operating sound level › Low energy consumption › Extension possible up to 195kW › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Remote cooling or heating selection › Water/water heat pump, with water reversibility › Compatible with hydraulic module EHMC › μC² SE controller › pCO3 controller for assembly of 2 or 3 modules

Water cooled chiller

283

13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 195

16.6 27.3 35.4 41.2 54.8 71.4 82.7 110 126 143 154 165 181 198 214 226 237 2481 2 4 6

3.61 5.79 7.48 8.75 11.80 15.50 17.60 23.6 27.3 31.0 33.1 35.2 39.1 42.8 46.5 48.6 50.7 52.83.60 3.71 3.74 3.71 3.64 3.61 3.69 3.64 3.63 3.61 3.66 3.69 3.63 3.62 3.61 3.64 3.67 3.69

600x600x600 600x600x1,200 1,200x600x1,200 1,800x600x1,200118 155 165 172 300 320 334 600 620 640 654 668 920 940 960 974 988 1.002

62 103 134 155 205 268 311 205 268 311 205 268 311

19 31 40 47 62 80 93 123 142 161 173 186 204 222 241 254 267 28037 62 80 93 123 161 186 247 284 321 347 373 407 444 482 507 533 55975 123 161 186 247 321 373 493 568 642 694 745 814 889 963 1,015 1,066 1,118

24 39 51 59 79 102 118 157 181 205 221 237 260 283 307 323 339 35548 78 102 118 157 205 237 314 362 410 442 474 519 567 614 647 679 711

95 157 203 237 314 410 474 629 724 819 883 948 1,038 1,133 1,229 1,293 1,357 1,42264 71 67 74 71 75 77 73 76 78 79

-10 (OPZL) ~ 2520 ~ 55

1 2 4 6

1.2 2 2.5 3.1 4.6 5.6 9.2 10.2 11.2 13.8 14.8 15.8 16.8

3N~ / 50 / 400

283

EWWP014-035KBW1N

EWWP-KBW1N

μC² SE

GC_pre2_lowres.pdf 283 30/11/2011 12:31:54

Page 286: DAIKIN General Catalogue 2012

SELECTION TABLE 1 MODULE (KB-SERIES) 2 MODULES (KB-SERIES) 3 MODULES (KB-SERIES)

Capacity index

Cooling capacity (kW)

Heating capacity (kW)

UNIT

+

CONTROL

(Factory mounted)

EWWP014KBW1NEWWP022KBW1NEWWP028KBW1NEWWP035KBW1NEWWP045KBW1NEWWP055KBW1NEWWP065KBW1N

MODULAR UNITS(Controller available as accessory)

EWWP045KBW1MEWWP055KBW1M

EWWP065KBW1M

CONTROL

(kit)ECB2MUWECB3MUW

For example: for a 121 kW HP system, select : EWWP055KBW1N + EWWP065KBW1N

Water cooled chiller

014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 195

13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 195

16.6 27.3 35.4 41.2 54.8 71.4 82.7 110 126 143 154 165 181 198 214 226 237 248

1 - - - - - - - - - - - - - - - - -

- 1 - - - - - - - - - - - - - - - -

- - 1 - - - - - - - - - - - - - - -

- - - 1 - - - - - - - - - - - - - -

- - - - 1 - - - - - - - - - - - - -

- - - - - 1 - - - - - - - - - - - -

- - - - - - 1 - - - - - - - - - - -

- - - - - - - 2 1 - - - 2 1 - - - -

- - - - - - - - 1 2 1 - 1 2 3 2 1 -

- - - - - - - - - - 1 2 - - - 1 2 3- - - - - - - 1 1 1 1 1 - - - - - -

- - - - - - - - - - - - 1 1 1 1 1 1

EWWP014-035KBW1N

EWWP090-130KBW1N

EWWP145-195KBW1N

284

EWWP-KBW1N

GC_pre2_lowres.pdf 284 30/11/2011 12:31:54

Page 287: DAIKIN General Catalogue 2012

285

Heating only & Cooling onlyCapacity classCooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERESEERCOPDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger Type Brazed plate, one per circuitWater heat exchanger - evaporator

Water volume l

Nominal water pressure drop Cooling Heat exchanger kPaWater heat exchanger - condenser

Type Double pass shell and tubeWater flow rate Nom. l/sNominal water pressure drop Cooling kPa

Sound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet mmCondenser water inlet/outlet inch

Power supply Phase/Frequency/Voltage Hz/V

› Compact design to allow easy indoor installation or retrofit operations › Daikin semi-hermetic single screw stepless compressor › High efficiency at full and partial load › Chilled water temperatures down to -10°C on standard unit › Optimised for use with R-134a › MicroTech III controller

Water cooled chiller, standard efficiency, standard sound

285

120 140 150 180 210 250 280 310 330 360 380 400 450 500 530 560120 146 155 178 208 256 285 310 334 357 386 416 464 513 541 570

142 172 188 216 249 305 340 377 405 432 466 499 554 610 645 681

25 12.527.3 33.3 38.5 44.2 49.3 58.7 68.3 77 82.7 88.4 98.6 108 117 127 137

32.9 40.1 46.4 53.5 59.57 71.68 80.75 92.88 99.9 107 113 119 131 143 152 162

4.40 4.38 4.03 4.22 4.37 4.18 4.03 4.04 3.91 4.22 4.30 4.38 4.26 4.16

5.01 4.67 4.66 4.75 5.20 4.46 4.80 4.84 5.00 4.79 5.17 5.27 5.37 5.25 4.81

4.32 4.29 4.05 4.04 4.18 4.26 4.21 4.06 4.05 4.04 4.12 4.19 4.22 4.26 4.23 4.22

1,020x913x2,684 2,000x913x2,684

1,177 1,233 1,334 1,366 1,416 1,600 1,607 2,668 2,700 2,732 2,782 2,832 3,016 3,200 3,207 3,2151,211 1,276 1,378 1,415 1,473 1,663 1,675 2,755 2,792 2,830 2,888 2,946 3,136 3,327 3,338 3,350

14 18 14 17 20 26 29 31 33 37 41 46 5215 13 40 38 36 28 33 40 38 36 28 33

7.04 8.57 9.25 10.62 12.30 15.06 16.89 18.49 19.91 21.28 23.15 24.59 27.33 30.10 31.92 33.7820 12 11 16 26 11 16 26

88.6 87.2 92.4 91.8 91.0

71.4 70.0 74.4 73.8 73.0

-10~1523~60

18 20 33 34 36 38 66 67 68 70 72 74 76

1 276.2

2.5 4

3~/50/400

285

EWWD-J-

EWWD-J-SS

MicroTech III

GC_pre2_lowres.pdf 285 30/11/2011 12:31:54

Page 288: DAIKIN General Catalogue 2012

286

Heating only & Cooling onlyCapacity class 170 210 260 300 320 380 420 460 500 600Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Single pass shell and tubeWater volume l

Nominal water pressure drop

Cooling Total kPa

Water heat exchanger - condenser

Type Single pass shell and tubeWater flow rate Nom. l/sNominal water pressure drop

Cooling kPa

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgControl Electronic expansion valveCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet 88.9mm 114.3mm 139.7mmCondenser water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› High efficiency (XS) › All models are PED pressure vessel approved › Stepless single-screw compressor › Optimised for use with R-134a › EER range up to 4 (SS) , 4.73 (XS) › 1-2 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return › Partial and total heat recovery option available › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Water cooled chiller

Standard efficiency

Standard sound

286

166 201 253 280 334 372 403 448 494 556

204 247 310 343 410 456 494 552 610 674

25 12.542.2 50.6 64.9 75.3 84.3 93 101 115 129 150

52.7 63.5 80.8 89.2 106 117 127 144 161 177

3.93 3.97 3.90 3.72 3.96 4.00 3.97 3.89 3.83 3.70

3.87 3.89 3.84 3.88 3.91 3.89 3.84 3.79 3.81

5.00 5.04 4.95 4.72 5.28 5.33 5.29 5.19 5.1 4.931,860x920x3,435 1,880x860x4,305

1,393 1,410 1,503 2,687 2,697 2,702 2,757 2,7621,470 1,480 1,650 2,840 2,850 2,860 2,970

60 56 123 118 113 173 168

48 69 43 53 64 63 72 54 68

9.95 12.02 15.19 16.98 19.99 22.22 24.08 26.90 29.77 33.73

39 41 63 77 40 41 57 60 75

87.7 90.2

69.7 71.7

-8~1520~55

50 55 110 50 55 110

1 2

5"

3~ / 50 / 400

286

EWWD-G-

EWWD-G-SS

MicroTech III

GC_pre2_lowres.pdf 286 30/11/2011 12:31:55

Page 289: DAIKIN General Catalogue 2012

287

Heating only & Cooling onlyCapacity class 190 230 280 320 380 400 460 500 550 650Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Single pass shell and tubeWater volume l

Nominal water pressure drop

Cooling Total kPa

Water heat exchanger - condenser

Type Single pass shell and tubeWater fl ow rate Nom. l/sNominal water pressure drop

Cooling kPa

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgControl Electronic expansion valveCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet 114.3mm 139.7mm 168.3mmCondenser water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

High efficiencyStandard sound

287

186 223 277 307 366 408 444 496 541 604

220 264 326 354 434 482 524 585 638 712

25 12.539.6 48.1 59.4 71.4 79.2 87.2 95.1 105 115 13750.1 60.6 74.5 83.7 99.9 110 120 132 144 162

4.70 4.64 4.66 4.30 4.62 4.68 4.67 4.73 4.72 4.39

4.38 4.35 4.38 4.23 4.34 4.38 4.42 4.43 4.40

5.97 5.9 5.92 5.46 6.15 6.24 6.23 6.31 6.30 5.851,860x920x3,435 1,880x860x4,305

1,650 1,665 1,680 2,800 2,945 2,955 2,975 2,9901,800 1,810 1,820 3,020 3,280 3,290 3,315 3,340

125 120 110 170 285 280

25 35 44 30 24 28 39 46 57

10.78 12.95 16.07 18.08 21.27 23.66 25.76 28.71 31.34 35.40

17 20 25 28 17 16 15 19

88.2 90.9

69.7 71.7

-8~1520~55

55 110 105 100

1 2

5"

3~ / 50 / 400

287

EWWD-G-XS

GC_pre2_lowres.pdf 287 30/11/2011 12:31:55

Page 290: DAIKIN General Catalogue 2012

288

Heating only & Cooling onlyCapacity class 340 400 460 550 650 700 800 850 900 950 C10 C12 C13 C14 C15 C16 C17 C18Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Single pass shell and tubeWater volume l

Nominal water pressure drop

Cooling Heat exchanger

kPa

Water heat exchanger - condenser

Type Single pass shell and tubeWater flow rate Nom. l/sNominal water pressure drop

Cooling kPa

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Control Electronic expansion valveCircuits Quantity

Refrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet 168.3mm 219.1mmCondenser water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

› High efficiency (XS) › All models are PED pressure vessel approved › Stepless single-screw compressor › Optimised for use with R-134a › Cooling range: 333–1,510kW (SS) , 362-1.134kW (XS) › EER range: 4.28 to 4.66 (SS) , 4.73 to 5.10 (XS) › 1-2-3 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side to minimize pressure drops › Partial and total heat recovery option available › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Water cooled chiller

288

333 394 460 538 640 705 782 844 910 986 1,027 1,155 1,204 1,274 1,346 1,401 1,455 1,510

388.4 460 538 630 757 832 919 993 1,072 1,161 1,217 1,363 1,427 1,507 1,227 1,661 1,730 1,790

25 12.5 8.371.5 85.8 101 120 141 156 171 186 200 218 237 254 268 282 298 317 335 353

87.4 104 122 143 174 191 208 225 243 262 282 309 326 344 363 383 401 420

4.66 4.59 4.56 4.47 4.53 4.52 4.57 4.55 4.51 4.33 4.54 4.50 4.51 4.43 4.35 4.28

4.44 4.42 4.41 4.35 4.36 4.42 4.41 4.43 4.32 4.41 4.38 3.38 4.34 4.31 4.26

5.06 4.96 4.93 4.86 5.54 5.75 5.56 5.7 5.47 5.61 5.36 5.51 5.56 5.54 5.55 5.45 5.271,821x1,430x3,398 2,113x1,350x4,361 2,323x2,135x4,426

2,150 2,160 2,179 2,224 3,909 3,927 3,945 3,971 3,996 4,080 4,092 6,079 6,097 6,136 6,174 6,192 6,210 6,2282,380 2,396 2,410 2,457 4,217 4,228 4,243 4,262 4,288 4,369 4,386 6,628 6,646 6,670 6,699 6,717 6,735 6,761

193 183 172 271 263 256 248 241 233 472 504 489 472

37 50 54 62 55 44 58 53 66 51 62 56 47 58 62 66 71

19.33 22.92 26.80 31.44 37.31 41.14 45.53 49.21 53.03 57.52 60.39 67.32 70.33 74.34 78.55 82.08 85.52 89.01

26 28 30 26 25 28 26 23 24 25 24 23

93.7 96.6 96.7 96.9 97.3 97.8 98.9 99.8 100.4 100.8 101.2 103.0

75.2 76.2 78.2 77.8 78.2 78.7 79.8 80.7 80.4 80.8 81.2 83.0

-8~1520~55

1 2 354 52 51 50 108 106 104 100 156 155 154 153 152 151 150

5"

3~ / 50 / 400

288

EWWD-I-

EWWD-I-SS

MicroTech III

Standard efficiency

Standard sound

GC_pre2_lowres.pdf 288 30/11/2011 12:31:55

Page 291: DAIKIN General Catalogue 2012

289

Heating only & Cooling onlyCapacity class 360 440 500 600 750 800 850 950 C10 C11 C12Cooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERCOPESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Single pass shell and tubeWater volume l

Nominal water pressure drop

Cooling Heat exchanger

kPa

Water heat exchanger - condenser

Type Single pass shell and tubeWater fl ow rate Nom. l/sWater fl ow

rate 2Nom. l/min

Nominal water pressure drop

Cooling kPa

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Control Electronic expansion valveCircuits Quantity

Refrigerant circuit Charge kgPiping

connectionsEvaporator water inlet/outlet 168.3mm 219.1mmCondenser water inlet/outlet

Power supply Phase / Frequency / Voltage Hz / V

High efficiencyStandard sound

289

362 433 506 573 720 795 866 933 976 1,038 1,134

410.9 493 577 660 823 908 990 1,069 1,126 1,203 1,313

25 12.571 85.4 100 121 141 156 170 185 199 219 240

85.9 103 121 143 172 189 206 223 240 263 285

5.10 5.07 5.06 4.75 5.09 5.10 5.08 5.05 4.9 4.73

4.78 4.79 4.77 4.62 4.78 4.80 4.81 4.79 4.69 4.57 4.61

5.34 5.27 5.22 5.11 6.13 6.31 6.01 6.14 5.9 6.05 5.671,883x1,430x4,081 2,245x1,350x4,769

2,594 2,667 2,704 4,964 4,997 5,049 5,073 5,097 5,1322,998 3,078 3,116 5,582 5,615 5,671 5,695 5,729 5,741

326 317 308 539 528 504

64 48 54 68 48 47 50 72 46 52

20.69 24.77 28.95 33.16 20.58 20.44 24.75 23.31 28.07 27.10 32.82

- 20.58 24.98 24.75 28 28.07 33 32.82

48 47 51 66 48 47 50 65

93.7 96.6 96.7 96.9 97.3 97.8 98.9 99.8

75.20 76.2 78.2 77.8 78.2 78.7 79.8 80.7

-8~1520~55

1 290 87 85 180 177 174 172 170

5"

3~ / 50 / 400

289

EWWD-I-XS

GC_pre2_lowres.pdf 289 30/11/2011 12:31:55

Page 292: DAIKIN General Catalogue 2012

290

Heating only & Cooling onlyCapacity classCooling capacity Nom. kWHeating capacity Nom. kWCapacity control Method Stepless

Minimum capacity %

Power input Cooling Nom. kWHeating Nom. kW

EERESEERCOPDimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Water heat exchanger - evaporator

Type Flooded shell and tubeWater volume l

Nominal water pressure drop Cooling Heat exchanger kPaWater heat exchanger - condenser

Type Flooded Shell & TubeWater fl ow rate Nom. l/sNominal water pressure drop Cooling kPa

Sound power level Cooling Nom. dBASound pressure level Cooling Nom. dBACompressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet mmCondenser water inlet/outlet inch

Power supply Phase/Frequency/Voltage Hz/V

› Cooling range: 369-1,215 kW › Condenser leaving water temperatures (CLWT) up to 65°C (optional) › Heat pump version available › Flooded type heat exchangers › MicroTech III controller

Water cooled chiller, high efficiency, standard sound

290

370 450 530 610 750 830 930 980 C10 C11 C12369 445 521 608 748 827 932 978 1,050 1,133 1,215

419 505 589 687 837 924 1,036 1,093 1,173 1,265 1,356

25 12.562.8 75.4 87.0 101 125 138 151 163 174 188 201

84.5 101 117 136 159 175 192 206 221 238 255

5.88 5.90 5.99 6.02 5.98 5.99 6.17 6.00 6.03 6.04

6.44 6.47 6.56 6.57 7.16 7.23 7.32 7.37 7.40 7.43 7.424.96 4.98 5.03 5.06 5.28 5.27 5.40 5.30 5.31 5.32 5.31

2,121x1,353x3,3412,121x1,353

x3,4192,048x1,384

x3,417 2,048x1,689x3,609 2,048x1,711x3,609 2,161x1,711x3,509

3,089 3,370 3,603 3,781 5,289 5,375 5,654 5,707 6,066 6,105 6,156

3,250 3,588 3,870 4,163 5,694 5,835 6,174 6,262 6,709 6,773 6,859

78 107 134 160 172 201 261 272 295 310 32748 40 38 42 48 40 38 35.0 37.0 40

20.63 24.86 29.05 33.87 41.71 46.11 51.74 54.52 58.48 63.12 67.6535 30 32 28 34 30 37 35.0 33.0 3596.7 97.7 98.7 99.1 100.2 100.7 101.2 101.7 102.2 102.778.0 79.0 80.0 81.0 81.5 82.0 82.5 83.0 83.5

-8~1518~65

210 190 180 210 220 250 300 3301

168.3 219.16 8

3~/50/400

290

EWWD-H-

EWWD-H-XS

MicroTech III

GC_pre2_lowres.pdf 290 30/11/2011 12:31:56

Page 293: DAIKIN General Catalogue 2012

291

Cooling onlyCapacity class 012 020 026 030 040 055 065Cooling capacity Nom. kWPower input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater heat exchanger - evaporator

Minimum water volume in the

systeml

Water flow rate Min. l/minNom. l/minMax. l/min

Model QuantityType Brazed plate

Sound power level Cooling Nom. dBACompressor Type Hermetically sealed scroll compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-407C

Control Thermostatic expansion valveCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet FBSP 25mm FBSP 40mmEvaporator water drain Field installation

Power supply Phase / Frequency / Voltage Hz / V

Condenserless chiller

› Daikin scroll compressor › Optimised for use with R-407C › Low operating sound level › Low energy consumption › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Compatible with hydraulic module › Main switch, pressure ports, flow switch, filter, shut-

off valves and air purge are standard included

› μC² SE controller

291

12.1 20.0 26.8 31.2 40.0 53.7 62.4

4.2 6.6 8.5 10.1 13.4 17.8 20.3

2.88 3.03 3.15 3.09 2.99 3.02 3.07600x600x600 600x600x1,200

108 141 147 151 252 265 274

62 103 134 155 205 268 311

17 29 38 45 57 77 8935 57 77 89 115 154 17969 115 153 179 229 307 358

1

64 71 67 74

-10~2025~60

1 2

3N~ / 50 / 400

291

EWLP-KBW1N

EWLP012-030KBW1N

μC² SE

GC_pre2_lowres.pdf 291 30/11/2011 12:31:56

Page 294: DAIKIN General Catalogue 2012

292

Cooling onlyCapacity class

Cooling capacity Nom. kW

Capacity control Method/Minimum capacity % Stepless/25 Stepless/12.5

Power input Cooling Nom. kW

EER

Dimensions Unit HeightxWidthxDepth mm

Weight Unit kg

Operation weight kg

Water heat exchanger - evaporator

Nominal water pressure drop Cooling Total kPa

Type Brazed plate, one per circuit

Sound power level Cooling Nom. dBA

Sound pressure level Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressor

Operation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDB

Refrigerant Type R-134a

Circuits Quantity

Piping connections Evaporator water inlet/outlet mm

Power supply Phase/Frequency/Voltage Hz/V

› Compact design to allow easy indoor installation or retrofi t operations › Daikin semi-hermetic single screw stepless compressor › High effi ciency at full and partial load › Chilled water temperatures down to -10°C on standard unit › Optimised for use with R-134a › MicroTech III controller

Condenserless chiller

standard efficiency, standard sound

292

110 130 145 165 195 235 265 290 310 330 360 390 430 470 500 530

110 128 143 164 192 237 265 286 307 328 356 383 429 474 502 530

30.9 38.0 43.3 49.8 55.3 65.2 74.5 86.5 93.0 99.5 105 111 121 130 140 149

3.55 3.36 3.31 3.30 3.47 3.63 3.56 3.31 3.30 3.39 3.47 3.56 3.63 3.59 3.56

1,020x913x2,684 2,000x913x2,684

1,124 1,141 1,237 1,263 1,305 1,489 2,474 2,500 2,526 2,568 2,611 2,795 2,979

1,138 1,159 1,253 1,281 1,327 1,518 2,505 2,533 2,562 2,608 2,655 2,845 3,036

14 12 36 34 32 25 31 36 34 32 25 31

88.6 87.2 92.4 91.8 91.0

71.4 70.0 74.4 73.8 73.0

-10~15

25~60

1 2

3"3~/50/400

292

EWLD-J-

EWLD-J-SS

MicroTech III

GC_pre2_lowres.pdf 292 30/11/2011 12:31:56

Page 295: DAIKIN General Catalogue 2012

Cooling onlyCapacity class 160 190 240 280 320 360 380 420 480 550Cooling capacity Nom. kWCapacity steps % stepless 25 - 100 stepless 12.5 - 100Power input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Minimum water volume in the system

l

Water fl ow rate Min. l/minNom. l/minMax. l/min

Nominal water pressure drop

Cooling Heat exchanger

kPa

Model QuantityType EV19270055 EV27270066 EV27270077 EV27270088 EV32270088 EV32270099

Type Shell and tube - direct expansionSound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgControl Electronic expansion valveCircuits Quantity

Piping connections Evaporator water inlet/outletPower supply Phase / Frequency / Voltage Hz / V

› Cooling range: 161-526kW › EER range: 3.48 to 3.70 › Stepless single-screw compressor › Optimised for use with R-134a › 1 or 2 truly independent refrigerant circuits › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return › All models are PED pressure vessel approved › MicroTech III controller

Condenserless chillerstandard efficiency, standard sound

161 189 244 270 316 352 381 428 476 526

45.4 54.3 65.9 74.6 90.6 99.7 108.6 120 131.5 148

3.54 3.48 3.70 3.62 3.48 3.53 3.51 3.57 3.62 3.551,860x1,000x3,700 1,942x1,100x4,400

1,280 1,398 2,442 2,446 2,501 2,506

1,337 1,516 2,560 2,670

1,151 1,354 1,749 1,938 1,130 1,262 1,365 1,535 1,704 1,884

230.20 270.90 349.74 387.58 452.22 504.83 546.25 613.90 681.84 753.80460.39 541.81 699.47 775.16 904.44 1,009.65 1,092.50 1,227.81 1,363.69 1,507.60649.15 763.95 986.26 1,092.97 1,275.27 1,423.61 1,540.42 1,731.21 1,922.80 2,125.71

48 69 43 53 64 63 72 54 68

1

88 90.5

69.7 71.7

-8~1525~60

5 10

1 288.9 114.3 139.7

3~ / 50 / 400

293

EWLD-G-SS

MicroTech III

EWLD-G-SS

GC_pre2_lowres.pdf 293 30/11/2011 12:31:57

Page 296: DAIKIN General Catalogue 2012

294

› Cooling range: 328–1,422kW › EER range: 3.51 to 3.91 › Stepless single-screw compressor › Optimised for use with R-134a › Standard electronic expansion valve › DX shell and tube evaporator – one pass refrigerant

side for easy oil circulation and return › All models are PED pressure vessel approved › MicroTech III controller for superior control logic and an easy interface

with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications

Condenserless chillerstandard efficiency, standard sound

Cooling onlyCapacity class 320 400 420 500 600 650 750 800 850 900 950 C10 C11 C12 C13 C14 C15 C16 C17Cooling capacity Nom. kWCapacity control Method % Stepless

Minimum capacityPower input Cooling Nom. kWEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Water fl ow rate Nom. l/minNominal water pressure drop

Cooling Total kPa

Type Single pass shell and tubeSound power level Cooling Nom. dBASound pressure level

Cooling Nom. dBA

Compressor Type Semi-hermetic single screw compressorOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDB 25~60Refrigerant Type R-134a

Charge kgControl Electronic expansion valveCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet

168.3mm 219.1mm

Power supply Phase / Frequency / Voltage Hz / V

294

328 391 428 504 596 657 730 788 850 919 966 1,033 1,078 1,125 1,188 1,267 1,319 1,370 1,422

25 12.5 8.383.8 100 116 137 165 181 198 214 231 252 271 279 296 312 329 347 366 386 405

3.91 3.9 3.7 3.67 3.61 3.63 3.69 3.67 3.65 3.56 3.59 3.64 3.60 3.61 3.65 3.60 3.55 3.51

1,899x1,464x3,114 2,325x1,464x4,391 2,415x2,135x4,426

1,861 1,869 1,884 3,331 3,339 3,347 3,356 3,364 3,412 5,146 5,167 5,188 5,2082,054 2,052 2,056 3,602 3,603 3,604 3,605 3,645 5,667 5,671 5,677 5,680

940.2 1,120.8 1,227.0 1,444.8 1,708.8 1,883.4 2,092.8 2,259.0 2,436.6 2,634.6 2,769.0 2,961.0 3,090.0 3,225.0 3,405.6 3,631.8 3,781.2 3,927.6 4,076.4

34 47 54 49 39 52 47 45 52 46 49 41 51 55 59 63

93.7 96.6 96.7 96.9 97.3 97.8 98.9 99.8 100.4 100.8 101.2 103 100.4 100.8 101.2 103

75.2 76.2 78.2 77.8 78.2 78.7 79.8 80.7 80.4 80.8 81.2 83 80.4 80.8 81.2 83

-8~15

5

1 2 3

3~ / 50 / 400

294

EWLD-I-SS

MicroTech III

EWLD-I-SS

GC_pre2_lowres.pdf 294 30/11/2011 12:31:57

Page 297: DAIKIN General Catalogue 2012

295

Cooling onlyCapacity class 320 430 520 640 860 C10Cooling capacity Min. kW

Max. kWCapacity control Method Variable speed centrifugal compressorPower input Cooling Min. kW

Cooling Max. kWEERESEERDimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater heat exchanger - evaporator

Type Flooded shell and tube (2 passes)Nominal water pressure drop

Cooling Heat exchanger

kPa

Water heat exchanger - condenser

Type Flooded shell and tube (2 passes)Water flow rate Nom. l/sNominal water pressure drop

Cooling kPa

Sound power level Cooling Nom. dBASound pressure

level

Cooling Nom. dBA

Compressor Type Oil free centrifugal compressor with magnetic bearingsOperation range Evaporator Cooling Min.~Max. °CDB

Condenser Cooling Min.~Max. °CDBRefrigerant Type R-134a

Charge kgControl Electronic expansion valveCircuits Quantity

Piping

connectionsEvaporator water inlet/outlet mmCondenser water inlet/outlet mm

Power supply Phase / Frequency / Voltage Hz / V

› Wide capacity range from 114 to 1,048 kW › An inverter driven compressor allows the capacity to be adjusted

precisely to match variations in room and outside temperatures › Top seasonal efficiency (ESEER up to 9.60) › Onboard digital electronics provide smart controls

Water cooled chiller with centrifugal compressor high efficiency, standard sound

295

114 128 172 114 128 172317 429 521 635 856 1,048

21.6 27.7 33.1 21.6 27.7 33.165.9 85.7 104 132 171 206

5.40 6.00 5.40 5.50 5.908.60 9.40 8.80 8.60 9.60

1,823x1,276x3,254 1,823x1,276x3,419 1,755x1,790x3,441 1,748x1,853x3,289 1,794x1,904x3,401

2,360 2,416 2,546 3,709 4,095 4,7652,520 2,634 2,812 4,074 4,548 5,330

30 31 23 18 21 11

18.3 24.6 29.9 36.7 49.1 59.9

24 25 28 24 25 29

89.0 90.1 91.2 92.4 93.6 94.6

70.9 72.0 73.0 73.8 75.1 75.9

2~1518~46

210 190 180 220 300

1

168.3 219.1 273168.3 219.1

3~ / 50 / 400

295

EWWD640-C10FZXS

EWWD-FZXS

pCO2

GC_pre2_lowres.pdf 295 30/11/2011 12:31:57

Page 298: DAIKIN General Catalogue 2012

296

› Single compressor unit up to 4.5MW › Dual compressor unit on single circuit up to 9MW › Optional variable speed drives (VFD) for superior partload performance › Compressor unloading down to 5% for dual compressor units and 10% for single

compressor units without hot gas bypass › Control flexibility for easy integration into BMS

WIDE CHOICE OF CAPACITIES AND EFFICIENCIES

Single compressor

› DWSC: 300 kW - 4,500 kW - Approximately 1.1 million possible chiller offerings with

combination options of motors, impellers, gears and vessels

Dual compressor

› DWDC: 600 kW - 9,000 kW - Approximately 0.75 million possible chiller offerings with

combination options of motors, impellers, gears and vessels

VARIABLE FREQUENCY DRIVE OPTION (VFD)

› Inverter technology greatly improving part load efficiency › Reducing annual energy costs

HIGH EFFICIENCY

› COP up to 7 at full load › COP up to 12 at partial load (when coupled with inverter VFD)

POWER LOSS DAMAGE PROTECTION

Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The

compressors are equipped with a lubricant reservoir and a

piston with a compressed spring that provides pressurized

lubricant to the bearings during the coast-down period. Also, the compressors decelerate quickly due to the low

inertia.

Piston

Lubricant reservoir

REFRIGERANT STORAGE CAPABILITY

The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate

this charge. This feature eliminates the need for separate storage vessels in most applications.

DWSC / DWDC Water cooled chiller with centrifugal compressor

GC_pre2_lowres.pdf 296 30/11/2011 12:31:58

Page 299: DAIKIN General Catalogue 2012

297

D D D D

UNMATCHED UNLOADING

Unloading to 10% of full load for a DWSC single compressor chiller and 5% for a DWDC dual

compressor unit, without using inefficient hot gas bypass. This unloading capability provides

improved stability of the chilled water temperature and less harmful cycling of compressors.Movable discharge diffuser increases stability and reduces vibrations.

Moveable diffuser closing off impeller discharge area

LOW OPERATIONAL SOUND LEVEL

Liquid Injection

A small amount of liquid refrigerant is taken from the condenser and injected into the

compressor discharge area. The liquid droplets absorb sound energy and reduce the

compressor's overall operational sound level. The droplets evaporate and reduce discharge

superheat.

Quieter as chiller unloads

Daikin’s design results in a reduction in sound levels at lower loads, where most chillers

spend most of their operating hours.

ONE DWDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR

CHILLERS

› Lower equipment costs than two separate chillers › Lower installation cost than two separate chillers › Lower annual operating cost than either one large or two small chillers › Less equipment room space required than for two separate chillers

(smaller footprint) › Capacity reduction to 5% of design value › Standby redundancy for most of the cooling season options of motors, impellers, gears

and vessels

EXCELLENT PART LOAD EFFICIENCY

When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on

a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs

to the dual compressor chiller produces a very high ARI certified Integrated Part Load Value (IPLV).

PARTIAL LOADS EFFICIENCY FOR 2,000 kW CENTRIFUGAL UNIT

DWSC: single compressorDWDC: double compressorVFD: compressor inverterSpecific selections can vary up or down from this example.

10.0

9.0

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.07.0 7.4 9.7 10.0

GC_pre2_lowres.pdf 297 30/11/2011 12:31:58

Page 300: DAIKIN General Catalogue 2012

Daikin Integrated Chiller Network

APPLICABLE SERIES:

› EWAQ080-260DAYN (R-410A) › EWYQ080-250DAYN (R-410A)

Daikin chillers can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a

single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is

also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable

operation of the chiller plant.

This function enables a Daikin chiller plant to be operated via a single controller.

Please note that DICN is only possible within the same series.

298

D.I.C.N.

GC_pre2_lowres.pdf 298 30/11/2011 12:31:58

Page 301: DAIKIN General Catalogue 2012

Hydraulic Module / Buffer Tank

› 3 models available › 100 l tank for all sizes › freeze up protection › high static pump (option) › standard drain kit (for indoor use) › standard dual pressure ports (before & behind the pump)

HYDRAULIC MODULEEHMC-AV

Nominal flow l/minNominal ESP mH

2O

Nominal input WDimensions (HxWxD) mmMachine weight kgSound power dBASound pressure dBAPower supply V1 1~/230V/50HzOperation range Water side °C

Air side °CDBPiping connections Water inlet/outlet

Drain connection

BUFFER TANK

Water flow

mH2O

55

50

45

40

35

30

25

20

15

10

5

00 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min)

LEGENDS

Pump characteristics1. EHMC30AV10802. EHMC10AV1080 &

EHMC15AV10803. EHMC30AV10104. EHMC10AV1010 &

EHMC15AV1010

Hydraulic module

+ filter pressures losses5. EHMC15/30AV1010 &

EHMC15/30AV10806. EHMC10AV1010 &

EHMC10AV1080

MODEL Description Volume Dimensions Unit weight

EKBT Buffer tank with cabinet 200l 1,284x637x754 86.5

EKBT500C Buffer tank with cabinet 500l 1,200x1,200x1,950 160

EKBTC10C Buffer tank with cabinet 1,000l 1,200x1,450x1,950 185

EKBT500N Buffer tank 500l 710x1,670 70

EKBTC10N Buffer tank 1,000l 860x2,020 100

The Daikin EKBT is a hydraulic kit for in or outdoor installation. It is designed to be installed with EUWA/Y-KBZW1 series, in closed systems, and can be used for water and glycol applications.

10 15 30

1010 1080 1010 1080 1010 1080

62 88 18717 34 15 27 10 27

630 1,050 650 1,070 1,070 2,0901,284x635x688 1,284x635x688 1,284x635x688

99 101 102 104 105 111

63 63 6352 52 52

-10°C ~ 55°C-10°C ~ 43°C

1" BSPF 2" BSPF 2-1/2" BSPF

1/2"

299

EHMC/EKBT

EHMC10-15-30AV1010

GC_pre2_lowres.pdf 299 30/11/2011 12:31:58

Page 302: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 300 30/11/2011 12:31:58

Page 303: DAIKIN General Catalogue 2012

301

) ���6.7�8�.25Cassette units 303

FWC-BT/BF 303FWF-BT/BF 304

FWC-AT/AF 305FWF-CT 306

Concealed ceiling units 307

FWB-BT 307FWB-JT/JF 308

Wall mounted unit 309

FWT-BT 309

Flexi type units 310

FWL-DT/DF 310FWM-DT/DF 311

FWD-AT/AF 312

Floor standing unit 313

FWV-DT/DF 313

For more information on Options & Accessories, please refer to page 362 of this catalogue.

GC_pre2_lowres.pdf 301 30/11/2011 12:31:59

Page 304: DAIKIN General Catalogue 2012

Portfolio Fan coil units

1 2 3 4 5 6 7 8 9 10 11 12 16 18 20 22kWReference

FWC

-BT/B

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FW

F-B

T/B

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FWC

-AT/A

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FW

F-C

T

2-pipe

cooling

heating

FWB

-JT/J

F 2-pipe

cooling

heating

4-pipe

cooling

heating

(4-pipe)

FW

T-B

T

2-pipe

cooling

heating

FW

V-D

T/D

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FWB

-BT

2-pipe

cooling

heating

4-pipe

cooling

heating

FWD

-AT/A

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FWM

-DT/D

F 2-pipe

cooling

heating

4-pipe

cooling

heating

FW

L-D

T/D

F 2-pipe

cooling

heating

4-pipe

cooling

heating

302

02 03 04

02 03 04

02 03 05

02 03 04 05 06

04 06

04

04

04 06 08 10 12 16 18

08 10 12 16 18

08 10 12 1816

1218

1608

100604

06

06

07

07

07

06

06

06

02

02

03

03

03

04

04

04

05

05

05

08

08

09

09

09

10

10

10

0607

050910

0802

0403

02 08

06

06

07

07

08

08

09

09

06 07 08

06 07 08 09

09

03 04

02 03 04

02

05

05

02 0304 05

03 0402 05

02 03 06 08 10

01 02 03 04 06 08 10

02 03 06 08 10

02 03 0406 08

04

04

10

01

01

01

02

02 03 04 06 07 08

05 06 07 08 09 1110

02 03 04 06 10

03 04 05 06 08 09 10 11

07 08

02 07

10

0304

02 03 06 08 10

01 02

02

03

03

03

04

04

0604

06

06

08

08

08 10

10

04

1002

01

01

01

03

03

03

04

02

02

03

01

02

04

04

0604

06

06

06

08

08

08

08

10

10

10

10

0202

01

01

01

07

02 04 05 06

08 10 11 12

02 0304

07 08 10 11 12

03

0506

04

GC_pre2_lowres.pdf 302 30/11/2011 12:31:59

Page 305: DAIKIN General Catalogue 2012

303

Indoor units 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater pressure

dropCooling kPaHeating kPa

Fan Type Turbo fan Turbo fanAir flow rate High m³/h

Sound power level High dBASound pressure level High dBAPower supply Phase/Frequency/Voltage Hz/V

› 360° air discharge ensures uniform air flow and temperature distribution › Modern style decoration panel in white › Fresh air intake for healthy living › Comfortable horizontal air discharge ensures draughtfree

operation and prevents ceiling soiling › Possibility to shut 1 or 2 flaps for easy installation in corners › Standard drain pump with 850mm lift

Round flow cassette

303

FWC06BT FWC07BT FWC08BT FWC09BT FWC06BF FWC07BF FWC08BF FWC09BF

5.0 5.6 6.3 7.2 4.9 5.6 6.3 7.2

3.4 4.0 4.5 5.3 3.4 3.9 4.4 5.2

6.3 7.1 8.3 9.5 -

- 6.2 6.8 7.8 8.8

40 46 58 76 41 47 59 77288x840x840 288x840x840

26 2915 19 26 34 15 19 25 3215 19 26 34 24 30 38 47

1,062 1,236 1,518 1,776 1,032 1,200 1,476 1,746

36 39 44 49 36 39 44 4924 28 32 37 24 28 32 37

1~/50/220-240 1~/50/220-240

303

FWC-BT/BF

FWC-BT/BF

BRC315D7 BRC7E532F

GC_pre2_lowres.pdf 303 30/11/2011 12:31:59

Page 306: DAIKIN General Catalogue 2012

304

Indoor units 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WDimensions Unit HeightxWidthxDepth mmWeight Unit kgWater pressure

dropCooling kPaHeating kPa

Fan Type Turbo fan Turbo fanAir flow rate High m³/h

Sound power level High dBASound pressure level High dBAPower supply Phase/Frequency/Voltage Hz/V

› Modern style decoration panel in white › Compact casing (570mm in width and depth) enables

unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

› Comfortable horizontal auto swing ensures draughtfree operation and prevents ceiling soiling

› Fresh air intake for healthy living › Possibility to shut 1 or 2 flaps for easy installation in corners › Standard drain pump with 750mm lift

4-way blow ceiling mounted cassette

304

FWF02BT FWF03BT FWF04BT FWF05BT FWF02BF FWF03BF FWF04BF FWF05BF

1.7 2.8 3.3 4.0 1.7 2.3 2.8 3.5

1.3 1.7 2.1 2.7 1.3 1.7 2.3

2.6 3.4 4.1 5.3 -

- 3.1 3.3 3.9 4.8

67 70 89 67 62 74 93285x575x575 285x575x575

19 19 206 19 31 42 6 13 21 336 19 31 42 12 6 9 13

468 660 876 468 438 618 82240 44 49 40 42 46 51

27 33 39 27 29 35 41

1~/50/220-440 1~/50/220-440

304

FWF-BT/BF

FWF-BT/BF

BRC315D7 BRC7E532F

GC_pre2_lowres.pdf 304 30/11/2011 12:31:59

Page 307: DAIKIN General Catalogue 2012

305

Indoor units 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgHeat exchanger Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Direct drive turbo fan Direct drive turbo fanAir flow rate High m³/h

Sound power level High dBASound pressure level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase/Frequency/Voltage Hz/V

› Wide operating range › Easy installation and maintenance › Flexibility (2-pipe or 4-pipe) › 3-speed fan motor › Double-intake centrifugal fans › Air suction from underneath › High power air flow › Removable washable air filter (self-extinguishing class 1) › Built-in high pressure drain pump with 700mm lift › Infrared remote control as standard with decoration panel kit

4-way blow ceiling mounted cassette

305

FWC07AT FWC08AT FWC10AT FWC11AT FWC12AT FWC02AF FWC03AF FWC04AF FWC05AF FWC06AF

6.63 7.50 8.80 9.95 10.80 3.81 3.96 4.63 5.01 5.16

4.90 5.40 6.40 7.10 7.70 3.40 3.52 4.07 4.40 4.54

8.40 9.50 11.00 12.00 12.90 -

- 10.55 10.99 12.51 13.48 13.77

127 151 164 192 253 122 138 153 184 2320.52 0.64 0.68 0.79 1.06 0.53 0.61 0.67 0.80 1.02

335x820x821 335x820x821

31.0 32.0 35.0 38.0 40.0 31.0 32.0 35.0 38.0 40.034.0 35.0 38.0 41.0 43.0 34.0 35.0 38.0 41.0 43.0

2.69 2.691,140 1,290 1,514 1,711 1,858 655 681 796 862 8881,140 1,290 1,514 1,711 1,858 907 945 1,076 1,159 1,184

24.8 30.8 41.6 52.2 69.3 3.56 3.78 4.94 5.70 5.96

21.4 26.8 35.3 45.2 64.1 4.8 5.5 7.2 8.6 8.9

1,310 1,380 1,560 1,740 1,840 1,310 1,380 1,560 1,740 1,84052 55 60 61 64 52 55 60 61 64

42 45 49 51 53 42 45 49 51 5319.05 19.053/4 3/4

1~/50/220-240 1~/50/220-240

305

FWC-AT/AF

FWC-AT/AF

SRC-COA/HPA WRC-COB/HPB

GC_pre2_lowres.pdf 305 30/11/2011 12:32:00

Page 308: DAIKIN General Catalogue 2012

306

Indoor units 2-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgWater pressure

dropCooling kPaHeating kPa

Fan Type Direct drive turbo fanAir flow rate High m³/h

Sound power level High dBASound pressure level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase/Frequency/Voltage Hz/V

› 4 way air discharge and air swing › Compact casing (570mm in width and depth) enables

unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

› Wide operating range › Air suction from underneath › Easy installation and maintenance › Built-in high pressure drain pump with 700mm lift › Double-intake centrifugal fans › High power air flow › 3-speed fan motor › Infrared remote control as standard with decoration panel kit

4-way blow ceiling mounted cassette

306

FWF02CT FWF03CT FWF04CT

2.49 4.10 4.54

1.91 2.93 3.37

3.52 4.69 5.28

-

63 64 790.27 0.28 0.34

250x570x57022 2322 23

19.00 27.00 29.0017.00 24.00 27.00

646 680 74852 54 56

42 45 4819.053/4

1~/50/220-440

306

FWF-CT MERCA WRC-COB/HPB

FWF-CT

SRC-COA/HPA

GC_pre2_lowres.pdf 306 30/11/2011 12:32:00

Page 309: DAIKIN General Catalogue 2012

Concealed ceiling unit

› Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor

› Compact dimensions, can easily be mounted in a narrow ceiling void › 3, 4 or 6 stage row cooling coil › Drain pan to collect the condensate from: heat exchanger

and regulating valves › 7-speed electrical motors (with thermal protection on windings) › All 7 speeds pre-wired in the factory in the terminal block of the switch box › The air filter can easily be removed for cleaning

Indoor units 2-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe* High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgHeat exchanger Water volume l

Additional heat exchanger

Water volume l

Water flow Cooling l/hHeating l/hAdditional heat exchanger l/h

Water pressure

dropCooling kPaHeating kPaAdditional heat exchanger kPa

Fan Type Centrifugal - forward blades - directly coupled on fan motorAir flow rate High m³/hAvailable pressure High Pa

Sound power level High dBASound pressure level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inch

Add. heat exchanger inchPower supply Phase / Frequency / Voltage Hz / V

*4-pipe = 2-pipe + option additional heat exchanger

FWB02BT FWB03BT FWB04BT FWB05BT FWB06BT FWB07BT FWB08BT FWB09BT FWB10BT

2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.34

1.88 2.16 2.34 3.6 3.87 4.4 5.23 5.96 6.95.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78

3.14 5.99 12.879 154 294

0.36 0.73 1.28239x1,039x609 239x1,389x609 239x1,739x609

23 24 26 31 33 35 43 45 4824 26 28 33 35 38 45 48 521.1 1.5 2.2 1.6 2.1 3.2 2.1 2.8 4.2

0.4 0.6 1.7

448 539 598 873 936 1,111 1,299 1,488 1,774

480 527 567 904 999 1,077 1,319 1,479 1,647275 526 1,123

8 14 11 15 8 14 21 26

7 10 8 12 7 10 16 15 183 5 8

400 800 1,20071 65 5956 59 69

44.5 47.5 57.516

3/43/4 1

1~ / 50 / 230

307

FWB-BT

FWEC1, 2, 3AFWB04BT

GC_pre2_lowres.pdf 307 30/11/2011 12:32:00

Page 310: DAIKIN General Catalogue 2012

Concealed ceiling unit

› Wide operating range › Quiet operation via enlarged fan wheels › Easy maintenance: filter can be removed from both sides

and beneath (maximum filter size is 400mm) › Flexibility (2-pipe or 4-pipe) › 4-speed fan motor › Direct driven centrifugal fans › Flexibility via interchangeable water connection side › High power air flow › Available static pressure of 30 Pa › Extended drain pan as standard › Standard Filter › Insulated with self-extinguishing class 1 heat insulation › Electronic room thermostat

Indoor units 2-PIPE 4-PIPE

FWB02JT FWB03JT FWB04JT FWB05JT FWB06JT FWB07JT FWB08JT FWB09JT FWB10JT FWB11JT FWB02JF FWB03JF FWB04JF FWB06JF FWB07JF FWB08JF FWB10JF

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mm

Weight Unit kgOperation weight kg

Heat exchanger Water volume l

Water flow Cooling l/hHeating l/hAdditional heat exchanger l/h

Water pressure drop

Cooling kPaHeating kPaAdditional heat exchanger kPa

Fan Type Direct driven centrifugal fan (forward-curved blades)hot-galvanised steel

Air flow rate High m³/hAvailable pressure High Pa

Sound power level High dBASound pressure level High dBAWater connections Std. heat exchanger inchPower supply Phase / Frequency / Voltage Hz / V

1.64 2.67 2.99 3.34 4.81 5.31 6.16 7.26 8.49 8.99 1.67 2.67 3.03 4.88 5.33 6.53 8.21

0.94 1.88 1.95 2.07 3.40 4.15 4.39 5.06 6.37 6.41 0.97 1.83 1.93 3.41 4.01 4.91 6.282.16 3.62 3.97 4.11 6.30 7.47 8.09 9.64 11.57 11.71 2.12 3.69 3.87 6.40 7.52 9.01 11.09

- 2.49 3.92 4.43 6.70 8.16 9.56 11.6834 53 57 54 86 121 117 134 164 166 34 51 54 84 117 137 1630.15 0.24 0.26 0.25 0.39 0.55 0.53 0.61 0.75 0.15 0.23 0.25 0.38 0.53 0.62 0.74

251x814

x590251x984

x590251x1,114x590

251x1,314

x590251x1,564x590

251x1,664

x590251x1,924x590

251x814

x590251x984

x590251x1,114

x590251x1,314

x590251x1,564

x590251x1,664

x590251x1,924

x59020.0 23.0 28.0 31.0 33.0 44.0 48.0 52.0 50.0 56.0 22.0 27.0 31.0 36.0 48.0 52.0 56.020.7 24.0 29.1 32.5 34.4 45.8 50.4 54.6 52.4 59.1 22.9 28.3 32.5 37.9 50.4 54.6 59.10.69 0.95 1.14 1.52 1.44 1.82 2.42 2.62 2.36 3.14 0.92 1.26 1.52 1.92 2.42 2.62 3.14

386 549 739 803 1,022 1,109 1,383 1,523 1,764 1,910 386 530 724 986 1,138 1,296 1,660386 549 738 802 1,020 1,107 1,336 1,524 1,764 1,911 387 530 725 985 1,139 1,299 1,660

- 269 391 493 663 820 924 1,14210.91 8.34 15.64 11.22 31.31 12.56 7.62 9.83 21.71 16.81 10.95 8.24 15.67 29.95 9.24 12.49 19.388.86 6.76 12.84 9.21 25.87 11.13 6.57 8.60 18.56 14.46 8.94 6.64 12.84 24.16 7.89 9.67 16.50

- 10.66 24.73 41.72 81.63 25.31 31.33 50.03

262 428 431 428 757 945 950 1,066 1,463 1,341 220 424 437 747 898 1,112 1,38530 30

47.5 52 49 50 52 55 55.5 56 47 52 50 52 55 56

35.5 40 37 38 40 39.5 43 43.5 44 35 40 38 40 39.5 43 44

3/4 3/41~ / 50 / 220-240 1~ / 50 / 220-240

308

FWB-JT/JF

FWB02JT/JF FWEC1, 2, 3A

GC_pre2_lowres.pdf 308 30/11/2011 12:32:00

Page 311: DAIKIN General Catalogue 2012

Wall mounted unit

› Wide operating range › Easy installation and maintenance › 3-speed fan motor › Double-intake centrifugal fans › Excellent air flow and air distribution › Flexibility via interchangeable water connection side › High power air flow › Insulated with self-extinguishing class 1 heat insulation › Removable washable air filter

(self-extinguishing class 1) › Slim and compact aesthetic design › Wireless remote control up to 9m distance, availability

of a wired or simplified controller › LED indicator gives an indication on the (normal

or wrong) operation of the unit

Indoor units 2-PIPE

FWT02BT FWT03BT FWT04BT FWT05BT FWT06BT

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kWPower input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kg

Operation weight kgHeat exchanger Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Direct drive cross flow fanAir flow rate High m³/h

Sound power level High dBASound pressure level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase / Frequency / Voltage Hz / V

2.34 2.78 3.22 4.54 5.281.74 2.03 2.35 3.65 4.333.02 3.75 4.10 6.01 6.74

24 25 29 66 690.11 0.13 0.29 0.30

260x799x198 260x899x198 304x1,062x22210 12 16

10 13 170.49 0.57 0.85402 478 554 781 908402 478 554 781 90848.3 64.7 69.3 50.3 69.342 58.6 60.6 50.6 70.6

467 510 586 1,070 1,121

53 55 61 64

40 39 42 49 5016 20

1/21~ / 50 / 220-240

309

FWT-BT

MERCAFWT05, 06BT SRC-COA/HPA WRC-COB/HPB

GC_pre2_lowres.pdf 309 30/11/2011 12:32:01

Page 312: DAIKIN General Catalogue 2012

310

Indoor units 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suctionAir flow rate High m³/h

Sound power level High dBAWater connections Std. heat exchanger inchPower supply Phase/Frequency/Voltage Hz/V

› Quick fixing system for wall or ceiling mounted installation › Pre-assembled 3-way/4-port on/off valves are available › Valve packages are insulated, no extra drain pan required › Valve packages contain balancing valves and sensor pocket › Fast-on connections for electrical options: no tools needed › The air filter can easily be removed for cleaning › Electric heater: no relay up to 2kW capacity › Electric heater: equipped with two overheat cut-out thermostats

Flexi type unit

310

FWL01DT FWL02DT FWL03DT FWL04DT FWL06DT FWL08DT FWL10DT FWL01DF FWL02DF FWL03DF FWL04DF FWL06DF FWL08DF FWL10DF

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88

1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85

2.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30

37 53 56 98 137 175 37 53 56 98 137 1750.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76

564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x251

20 21 27 32 33 44 21 22 28 34 35 46

0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,36245 50 47 52 56 58 64 45 50 47 52 56 58 64

1/2 3/4 1/2 3/41~/50/230 1~/50/230

310

FWL-DT/DF FWL-DT/DF

FWL-DT/DF

ECFWMB6FWEC1, 2, 3A

GC_pre2_lowres.pdf 310 30/11/2011 12:32:01

Page 313: DAIKIN General Catalogue 2012

311

Indoor units 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suctionAir flow rate High m³/h

Sound power level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase/Frequency/Voltage Hz/V

› Quick fixing system for wall or ceiling mounted installation › Pre-assembled 3-way/4-port on/off valves are available › Valve packages are insulated, no extra drain pan required › Valve packages contain balancing valves and sensor pocket › Fast-on connections for electrical options: no tools needed › The air filter can easily be removed for cleaning › Electric heater: no relay up to 2kW capacity › Electric heater: equipped with two overheat cut-out thermostats

Flexi type unit

311

FWM01DT FWM02DT FWM03DT FWM04DT FWM06DT FWM08DT FWM10DT FWM01DF FWM02DF FWM03DF FWM04DF FWM06DF FWM08DF FWM10DF

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88

1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85

2.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30

37 53 56 98 137 175 37 53 56 98 137 1750.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76

535x584x224 535x794x224 535x1,004x224 535x1,214x249 535x584x224 535x794x224 535x1,004x224 535x1,214x24914 15 19 23 32 15 16 20 25 34

0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,36245 50 47 52 56 58 64 45 50 47 52 56 58 64

17 171/2 3/4 1/2 3/4

1~/50/230 1~/50/230

311

FWM-DT/DF FWM-DT/DF

FWM-DT/DF

FWEC1, 2, 3A

GC_pre2_lowres.pdf 311 30/11/2011 12:32:01

Page 314: DAIKIN General Catalogue 2012

Flexi type unit

› Quick fixing system for wall or ceiling mounted installation › Straight duct connector is mounted to discharge side › Electronic controller with water probe, available in

standard, advanced and advanced plus version › The air filter can easily be removed for cleaning

Indoor units 2-PIPE 4-PIPE

FWD04AT FWD06AT FWD08AT FWD10AT FWD12AT FWD16AT FWD18AT FWD04AF FWD06AF FWD08AF FWD10AF FWD12AF FWD16AF FWD18AF

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Water volume l

Additional heat exchanger

Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suctionAir flow rate High m³/hAvailable pressure High Pa

Sound power level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase / Frequency / Voltage Hz / V

3.90 6.20 7.80 8.82 11.90 16.40 18.30 3.90 6.20 7.80 8.82 11.90 16.40 18.303.08 4.65 6.52 7.16 9.36 12.80 14.10 3.08 4.65 6.52 7.16 9.36 12.80 14.104.05 7.71 9.43 10.79 14.45 19.81 21.92 -

- 4.49 6.62 9.21 15.86 21.15234 349 443 714 1,197 234 349 443 714 1,1970.95 1.58 1.97 3.21 5.37 0.95 1.58 1.97 3.21 5.37

280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x718 280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x71833 41 47 49 65 77 80 35 43 50 52 71 83 86

1.06 1.42 1.79 2.38 2.5 4.02 5.03 1.06 1.42 1.79 2.38 2.50 4.02 5.03

- 0.35 0.47 0.59 1.42 1.72

674 1,064 1,339 1,514 2,056 2,833 3,140 674 1,064 1,339 1,514 2,056 2,833 3,140674 1,064 1,339 1,514 2,056 2,833 3,140 349 581 808 1,392 1,856

17 24 16 26 34 45 17 24 16 26 34 4514 20 13 21 28 37 9 15 13 12 16

800 1,250 1,600 2,200 3,000 800 1,250 1,600 2,200 3,00066 58 68 64 97 145 134 63 53 63 59 92 138 12866 69 72 74 78 66 69 72 74 78

16 16

3/4 1 3/4 1

1~ / 50 / 230 1~ / 50 / 230

312

FWD-AT/AF

FWD04AT/AFFWD04AT/AF FWEC1,2,3A

GC_pre2_lowres.pdf 312 30/11/2011 12:32:01

Page 315: DAIKIN General Catalogue 2012

313

Indoor unit 2-PIPE 4-PIPE

Cooling capacity Total capacity High kWSensible capacity High kW

Heating capacity 2-Pipe High kW4-Pipe High kW

Power input High WCurrent input High ADimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Water volume l

Water flow Cooling l/hHeating l/h

Water pressure

dropCooling kPaHeating kPa

Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suctionAir flow rate High m³/h

Sound power level High dBAPiping connections Drain OD mmWater connections Std. heat exchanger inchPower supply Phase/Frequency/Voltage Hz/V

› Quick fixing system for wall mounted installation › Pre-assembled 3-way/4-port on/off valves are available › Valve packages are insulated, no extra drain pan required › Valve packages contain balancing valves and sensor pocket › Fast-on connections for electrical options: no tools needed › The air filter can easily be removed for cleaning › Electric heater: no relay up to 2kW capacity › Electric heater: equipped with two overheat cut-out thermostats

Floor standing unit

313

FWV01DT FWV02DT FWV03DT FWV04DT FWV06DT FWV08DT FWV10DT FWV01DF FWV02DF FWV03DF FWV04DF FWV06DF FWV08DF FWV10DF

1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88

1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85

2.14 2.57 3.81 5.63 6.36 7.83 10.03 -

- 1.90 2.10 3.08 5.05 5.30 7.91 9.30

37 53 56 98 137 175 37 53 56 98 137 1750.17 0.24 0.25 0.44 0.43 0.60 0.76 0.17 0.24 0.25 0.44 0.43 0.60 0.76

564x774x226 564x984x226 564x1,194x226 564x1,404x251 564x774x226 564x984x226 564x1,194x226 564x1,404x251

19 20 25 30 31 41 20 21 26 32 33 44

0.5 0.7 1 1.4 2.1 0.5 0.7 1 1.4 2.1265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816

13 11 12 14 12 19 13 11 12 14 12 199 11 9 10 9 16 7 8 5 10 8 9

319 344 442 706 785 1,011 1,393 307 327 431 690 763 998 1,36245 50 47 52 56 58 64 45 50 47 52 56 58 64

16 16

1/2 3/4 1/2 3/41~/50/230 1~/50/230

313

FWV-DT/DF

FWV-DT/DF

ECFWMB6FWEC1, 2, 3A

GC_pre2_lowres.pdf 313 30/11/2011 12:32:01

Page 316: DAIKIN General Catalogue 2012

314

174

The D-AHU Professional is based on a completely modular design, capable of adapting to the needs of a variety of installation types. A wide standard range covers air fl ow rates from 1,100m³/h up to 124,000m³/h while paying special attention to energy effi ciency.

System highlights

› Custom modular design with variable dimensioning › Rigid 40mm and 60mm extruded aluminium profile structure › Double wall 25mm and 50mm foam or rockwool filled panels › Component flexibility for total air treatment: Heat Recovery &

Humidification › Air flow rates from 1,100 up to 124,000m3/h

Robust thermal-break construction

The air handling unit is constructed of aluminium, using anodised aluminium profi les and double-walled panels. The profi les have a section of 40x40mm or 60x60mm. The 60x60mm profi les are also available in a thermal-break version.

The following insulation material is used between the sheets: › Polyurethane foam (40-50 kg/m3) › Mineral wool, glued to the panel (90 kg/m3)

The panels are available as fl at panels or as step panels,which permit to obtain a fl at surface inside the unit.The inner and outer sheet of the panel can be made with the following materials:

› Plastisol › Galvanised steel › Aluminium › Stainless steel › Pre-painted

D-AHU Professional

D-AHU Professional 01-09

Air flow rate (m3/h) x 1,000

Mo

de

l siz

e

Speed 2.0 m/s

Speed 3.0 m/s

Speed 2.5 m/s

Speed 3.5 m/s

D-AHU Professional 10-18

Mo

de

l siz

e

Air flow rate (m3/h) x 1,000

D-AHU Professional 19-27

Air flow rate (m3/h) x 1,000

Speed 2.0 m/s

Speed 3.0 m/s

Speed 2.5 m/s

Speed 3.5 m/s

Speed 2.0 m/s

Speed 3.0 m/s

Speed 2.5 m/s

Speed 3.5 m/s

Daikin Air handling units

Aluminium profile with thermal break

Mo

de

l siz

e

GC_pre2_lowres.pdf 314 30/11/2011 12:32:02

Page 317: DAIKIN General Catalogue 2012

315

1 1,105 850 550

2 1,550 900 600

3 1,980 950 650

4 2,570 1,000 780

5 3,170 1,150 780

6 3,550 1,150 800

7 4,000 1,250 800

8 4,800 1,300 850

9 5,560 1,350 900

10 6,600 1,550 900

11 7,950 1,550 1,100

12 9,320 1,650 1,100

13 10,050 1,650 1,150

14 13,200 1,850 1,400

15 19,200 2,100 1,500

16 25,300 2,650 1,500

17 31,500 2,750 1,750

18 37,000 3,220 1,800

19 43,400 3,090 2,100

20 51,300 3,340 2,250

21 58,000 3,820 2,250

22 67,500 4,040 2,400

23 78,000 4,490 2,450

24 84,700 4,490 2,700

25 98 000 4,890 2,850

26 111,000 5,490 2,850

27 124,000 5,990 3,000

Daikin Air handling units

Damper

Heat recovery wheel

Humidifiers

› Surface evaporation humidifier › Water spray humidifier › Steam humidifier (on network with

generator) › Atomized water spray humidifier

Heat recovery

› Heat wheel ( efficiency 70 - 75%) › Plate heat exchanger (efficiency 50

- 60%) › Twincoil heat exchanger (efficiency

50 - 60%)

Filters

› Pre-filters: - Pleated filter (G3,G4) - Flat filter (G1,G2) › Medium efficiency filter:

- Bag filters (rigid or soft) (F5 - F9) › High efficiency filters (up to H13) › Active carbon filters

- Adsorption filters - Deodorizing filters

Heat exchangers

› Material: - Cu/Al - Cu/Al prepaint - Cu/Cu- galvanised Fe- RVS304- RVS316

› Water coil › Steam coil › Direct expansion coil › Superheated water coil › Electric coils

Centrifugal fans

› Forward bladed fans › Backward bladed fans › Centrifugal fan › Belt or direct drive

Other

› Damper › Mixed section › Empty section › Gas burner section › Drip tray

COMPONENTS OF THE D-AHU PROFESSIONAL

« Offer ing a comp lete range: f rom standard mode l s izes to customised so lu t ions. »

BASIC SPECIFICATIONS

Model sizeAir fl ow rate at

2.5m/sLength Height

GC_pre2_lowres.pdf 315 30/11/2011 12:32:02

Page 318: DAIKIN General Catalogue 2012

316316316

0

1

2

3

4

5

6

7

8

0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5

1.105 (m3/h)

1.550

1.980

2.600

3.170

3.550

4.000

4.800

4

9

10

11

12

13

14

15

6 8 10 12 14 16 18 20 22 24 26 28 30 32 34

5.560 (m3/h)

6.600

7.950

9.320

10.050

13.200

19.200

1,105 550 850

1,550 600 900

1,980 650 950

2,600 780 1,100

3,170 780 1,150

3,550 800 1,150

4,000 800 1,250

4,800 850 1,300

5,560 900 1,350

6,600 900 1,550

7,950 1,100 1,550

9,320 1,100 1,650

10,050 1,150 1,650

13,200 1,400 1,850

19,200 1,500 2,100

15,0001.500 2.100 1.95

1.500x1.700 1.500 1.700 2.48

RANGE

The range covers an area of air fl ow rates from 500 m3/h up to 30.000 m3/h*, with the possibility to choose the more appropriate face velocity, depending on the treatment required.

Pre defined sizes

Fifteen fi xed sizes optimized to reach the best compromise b.etween competitiveness and manufacturing standardization

Variable DimensioningTM

Designed to overcome installation constraints where space requirements of the section “height x width” must be adapted to the available space. The system gives the possibility to tailor the unit sizes through increments of 5 cm average.

Pre defined sizes - Overall dimension

D-AHU Easy

Daikin Air handling units

*Air Flow limits of 500 m3/h and 30.000 m3/h are calculated using non standard sizes (max dimensions 2.150x2.150) and considering 2,5 m/s coil face velocity

D-AHU Easy 1-8

D-AHU Easy 9-15

Flexible sizing for AHU optimization

• 5 cm increment for width & height dimensions

• No additional cost for non-standard unit size

• No additional lead time

Infinitely variable sizes

Example

Air flow rate (m3/h) x 1,000Air flow rate (m3/h) x 1,000

Mo

de

l siz

e

Mo

de

l siz

e

(Speed 2.5 m/s)(Speed 2.5 m/s)

Speed 2.0 m/s

Speed 3.0 m/s

Speed 2.5 m/s

Speed 2.0 m/s

Speed 3.0 m/s

Speed 2.5 m/s

SizeAir Flow (m3/h)Speed 2.5 m/s

Height - mm Width - mm

Std 1

Std 2

Std 3

Std 4

Std 5

Std 6

Std 7

Std 8

Std 9

Std 10

Std 11

Std 12

Std 13

Std 14

Std 15

Air Flow (m3/h)

Unit Size Height - mm Width - mmFace Velocity

m/s

STD 15

GC_pre2_lowres.pdf 316 30/11/2011 12:32:02

Page 319: DAIKIN General Catalogue 2012

317317317

Daikin Air handling unitsDaikin Air handling units

UNIT FEATURES

Panels

Hot injected Polyurethane panels to achieve excellent performance in terms of thermal insulation.

Optimized air face velocity

Automatic dimensioning of section in order to guarantee an optimal air face velocity on coils and optimized unit cost.

Construction

The exclusive fi xing method used for panels and profi les will ensure an uniform pressure on the whole profi le length. That feature will improve signifi cantly the air leakage rate.

Internal surface

Completely smooth internal surface.

Special gaskets

Utilization of special gasket will ensure internal insulation of the profi les and will help to improve the thermal bridging factor.

Unit competitiveness

Through Variable DimensioningTM exclusive design our clients are sure to invest only for the most optimized panel surface needed to match their requirements.

D-AHU EASY

GC_pre2_lowres.pdf 317 30/11/2011 12:32:02

Page 320: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 318 30/11/2011 12:32:02

Page 321: DAIKIN General Catalogue 2012

319

Daikin offers a wide range of condensing units for medium and low temperature refrigeration

applications. Daikin refrigeration units combine efficiency and reliability with easy installation

and maintenance.

,�),.9�, 2.6�Conveni-pack 320ZEAS condensing units 324

Commercial condensing units 326

Large variable capacity condensing unit 327

GC_pre2_lowres.pdf 319 30/11/2011 12:32:03

Page 322: DAIKIN General Catalogue 2012

320

CONVENIPACK IS A COMPACT, LOW NOISE SYSTEM

WHICH INTEGRATES HIGH AND LOW TEMPERATURE

REFRIGERATION AND AIR CONDITIONING

INCLUDING HEATING INTO ONE SYSTEM.

Helping retailers save energy and

the environmentRetailers are faced with a growing need for fresh goods,

prepared meals and chilled drinks. At the same time,

environmental and zoning requirements are stricter than ever,

and energy costs must be kept under control. Conveni-pack

minimises total energy demand due to its unique, integrated

approach to refrigeration and air conditioning.

A total solutionfor small applicationsConveni-pack is unique in combining refrigeration and air

conditioning equipment in one total solution using the

latest controls and inverter technology in order to maximize

energy effi ciency. The system can be connected to basically

all refrigeration applications and is supplied with a wide

range of air conditioning indoor units to respond to all shop

requirements. An optional booster unit is available for low

temperature refrigeration.

Conveni-pack

GC_pre2_lowres.pdf 320 30/11/2011 12:32:03

Page 323: DAIKIN General Catalogue 2012

321

› Inverter driven outdoor units match

system output to actual demand in

order to reach optimum effi ciency

under all conditions

› Conveni-pack supports a wide variety

of refrigeration and cooling units

› By recovering the heat extracted

from the connected refrigeration

appliances and by using sophisticated

controls energy savings of up to 50%

or more can be reached.

› Small footprint, reduced piping, quiet

operation: ideal for densely populated

urban areas

Heat RecoveryThe heat extracted from the refrigeration showcases or

evaporators can be re-used for comfort heating of the shop…

at no extra cost!

Reduced footprintThe Conveni-pack outdoor unit is compact when compared

to conventional systems. Its footprint is 60% smaller, allowing

it to be used in applications where space is restricted.

Heat

Recovery

LT1 refrigeration HT2 refrigeration Air conditioning

5.621m2

2.20m2

GC_pre2_lowres.pdf 321 30/11/2011 12:32:04

Page 324: DAIKIN General Catalogue 2012

322

A flexible system

for larger applicationsConveni-pack’s modular design allows it to be used

for smaller as well as larger shops. One or more

outdoor units can be installed throughout the building,

inside or outside.

Capacity rangeTwo types of outdoor units are available with different

refrigeration and heat recovery capacity. By combining

Conveni-pack and ZEAS condensing units the optimum

total solution for heating, AC and refrigeration can be

provided for virtually any shop concept.

Conveni-pack

GC_pre2_lowres.pdf 322 30/11/2011 12:32:04

Page 325: DAIKIN General Catalogue 2012

323

Low and medium temperature refrigerationIndoor units LRYEQ16AY1

Casing Colour Ivory white (Munsell code: 5Y7.5/1)Dimensions Unit HeightxWidthx

Depthmm

Weight Unit kgHeat exchanger Type Cross fin coilFan Type Propeller fan

QuantityAir flow rate Cooling Nom. m³/min

Fan motor Output WDrive Direct drive

Compressor N° of compressors 3Type Hermetically sealed scroll compressorPiston displacement m³/hSpeed rpmOutput WStarting method Direct on line (inverter driven)Frequency ON/OFF Less than 6 times/hour

Operation range Evaporator Cooling Min.~Max. °CDBRefrigerant Type R-410A

Charge kgControl Electronic expansion valve

Refrigerant oil Type Daphne FVC68DCharged volume l

Power supply Phase / Frequency / Voltage Hz / VVoltage range Min. %

Max. %

› Integrates high and low temperature refrigeration and air conditioning (including heating) into one system

› By using heat recovery, optimised controls and state of the art compressor technology, Conveni-pack can reduce annual energy consumption up to 50%, compared to conventional systems

› Lower associated CO2 emissions thanks to the heat pump technology

› Conveni-pack’s modular design allows it to be used for smaller as well as larger shops

› The modularity of the Conveni-pack system maximises installation flexibility. Outdoor units can be grouped into blocks or rows, or distributed around the building, to meet individual installation constraints

› The heat extracted from the refrigeration showcases or evaporators can be re-used for comfort heating of the shop at no extra cost

› Low sound level including "night mode" operation

Conveni-pack

(1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit

323

1,680x1,240x765

370

2230750

13.34 / 10.53 / 10.536,300 / 2,900 / 2,9002,500 / 3,600 / 4,500

-20 @ 0~10

11.5

1.7 (1) 2.1 (2) 2.1 (3) 4.0 (4)

3~ / 50 / 380-415-1010

323

LRYEQ16AY1

LRYEQ-AY1

GC_pre2_lowres.pdf 323 30/11/2011 12:32:04

Page 326: DAIKIN General Catalogue 2012

Medium temperature refrigerationIndoor units LRMEQ5AY1 LRMEQ6AY1 LRMEQ8AY1 LRMEQ10AY1 LRMEQ12AY1 LRMEQ15AY1 LRMEQ20AY1

Cooling capacity Nom. kWCasing Colour Ivory white (Munsell code: 5Y7.5/1)Dimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Type Cross fin coilFan Type Propeller fan

QuantityAir flow rate Cooling Nom. m³/min

Fan motor (1/2) Output WDrive Direct drive

Compressor N° of compressorsType Hermetically sealed scroll compressorPiston displacement m³/hSpeed rpmOutput WStarting method Direct on line (inverter driven)

Operation range Evaporator Cooling Min.~Max. °CDBAmbient temperature

Min. °CMax. °C

Refrigerant Type R-410ACharge kgControl Electronic expansion valve

Refrigerant oil Type Daphne FVC68DCharged volume l

Piping

connectionsLiquid 50m or less ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection)

50~130m ø 12.7 C1220T (Brazing connection) ø 15.9 C1220T (Brazing connection)Gas 50m or less ø 19.1 C1220T (Brazing connection) ø 25.4 C1220T (Brazing connection) ø 31.8 C1220T (Brazing connection)

50~130m ø 22.2 C1220T (Brazing connection) ø 28.6 C1220T (Brazing connection) ø 34.9 C1220T (Brazing connection)Power supply Phase / Frequency / Voltage Hz / VVoltage range Min.~Max. %

Current Nominal running

current (RLA) - 50HzComp 1 / Comp 2 / Comp 3

Cooling A

Current - 50Hz Starting current (MSC) AMinimum Ssc value kVaMinimum circuit amps (MCA) AMaximum fuse amps (MFA) ATotal overcurrent amps (TOCA) AFull load amps (FLA) Fan motor (1/2) A

› Medium temperature applications from -20°C to 10°C saturated suction temperature (LRMEQ-AY1)

› Low temperature applications from -40°C to -20°C saturated section temperature (LRLEQ-AY1)

› Perfect solution for applications with variable load conditions and high energy efficiency requirements such as supermarkets, cold storage, blast coolers and freezers etc.

› DC inverter scroll compressor with economiser function results in high energy efficiency and reliable performance

› Reduced CO2 emissions thanks to the use of R-410A

refrigerant and low energy consumption › Factory tested and pre-programmed for quick and

easy installation and commissioning › VRV® (Varable Refrigerant Volume) technology for flexible application range › Increased installation flexibility thanks to limited dimensions › Low sound level including "night mode" operation

ZEAS condensing units

12.2 14.4 18.6 21.8 24.4 32.2 37.0

1,680x635x765 1,680x930x765 1,680x1.240x765170 255 355

1 295 102 171 179 191 230 240

350.00 / - 750.00 / - 750.00 / 750.00

1 2 2

10.04 13.85 19.68 / 19.68 23.36 / 23.36 25.27 / 25.27 30 / 30 / 30 35.8 / 35.8 / 35.84,740 6,540 4,320 / 2,900 6,060 / 2,900 6,960 / 2,900 5,640 / 2,900 / 2,900 6,960 / 2,900 / 2,9002,300 3,200 2,100 / 3,600 3,000 / 3,600 3,400 / 3,600 2,800 / 3,600 / 3,600 3,400 / 3,600 / 3,600

-20~10-1543

5.2 7.9 11.5

1.7 (1) / 2.5 (4) 1.7 (1) / 2.5 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) / 2.1 (3) / 4.0 (4)

1.7 (1) / 2.1 (2) 2.1 (3) / 4.0 (4)

3~ / 50 / 380-415-10~10

7.0 / - / - 8.9 / - / - 5.2 / 6.8 / - 7.5 / 6.9 / - 9.5 / 7.7 / - 7.4 / 7.1 / 7.1 10.2 / 7.8 / 7.8

- 74 75 84

- 652 896 1,093 757 941

12.7 13.6 19.2 21.9 23.9 31.2 34.815 25 40

15.6 31.5 48.30.4 / - 0.9 / - 0.7 / 0.7

324

LR(M/L)EQ-AY1

LRMEQ-AY1

GC_pre2_lowres.pdf 324 30/11/2011 12:32:05

Page 327: DAIKIN General Catalogue 2012

Low temperature refrigerationIndoor units LRLEQ5AY1 LRLEQ6AY1 LRLEQ8AY1 LRLEQ10AY1 LRLEQ12AY1 LRLEQ15AY1 LRLEQ20AY1

Cooling capacity Nom. kWCasing Colour Ivory white (Munsell code: 5Y7.5/1)Dimensions Unit HeightxWidthxDepth mmWeight Unit kgHeat exchanger Type Cross fi n coilFan Type Propeller fan

QuantityAir fl ow rate Cooling Nom. m³/min

Fan motor (1/2) Output WDrive Direct drive

Compressor N° of compressorsType Hermetically sealed scroll compressorPiston displacement m³/hSpeed rpmOutput WStarting method Direct on line (inverter driven)

Operation range Evaporator Cooling Min.~Max. °CDBAmbient temperature

Min. °CMax. °C

Refrigerant Type R-410ACharge kgControl Electronic expansion valve

Refrigerant oil Type Daphne FVC68DCharged volume l

Piping

connectionsLiquid 50m or less ø 9.5 C1220T (Brazing connection) ø 12.7 C1220T (Brazing connection)

50~70m ø 12.7 C1220T (Brazing connection) ø 15.9 C1220T (Brazing connection)Gas 25m or less ø 19.1 C1220T (Brazing connection) ø 25.4 C1220T (Brazing connection) ø 31.8 C1220T (Brazing connection)

25~70m ø 22.2 C1220T (Brazing connection) ø 28.6 C1220T (Brazing connection) ø 34.9 C1220T (Brazing connection)Power supply Phase / Frequency / Voltage Hz / VVoltage range Min. %

Max. %

Current Nominal running current (RLA) - 50Hz

Comp 1/ Comp 2/ Comp 3

Cooling A

Current - 50Hz Starting current (MSC) AMinimum Ssc value kVaMinimum circuit amps (MCA) AMaximum fuse amps (MFA) ATotal overcurrent amps (TOCA) AFull load amps (FLA) Fan motor (1/2) A

(1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit

5.4 6.3 8.0 9.4 10.3 13.6 15.1

1,680x635x765 1,680x930x765 1,680x1.240x765170 255 355

1 295 102 171 179 191 230 240

350.00 750.00 750.00 / 750.00

1 2 3

10.04 13.85 19.68 / 19.68 23.36 / 23.36 25.27 / 25.27 30 / 30 35.8 / 35.84,740 6,540 4,320 / 2,900 6,060 / 2,900 6,960 / 2,900 5,640 / 2,900 / 2,900 6,960 / 2,900 / 2,9002,300 3,200 2,100 / 3,600 3,000 / 3,600 3,400 / 3,600 2,800 / 3,600 / 3,600 3,400 / 3,600 / 3,600

-45~-20-1543

5.2 7.9 11.5

1.7 (1) / 2.5 (4) 1.7 (1) / 2.5 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) /

3.0 (4)1.7 (1) / 2.1 (2) / 2.1 (3) / 4.0 (4)

1.7 (1) / 2.1 (2) / 2.1 (3) / 4.0 (4)

3~ / 50 / 380-415-1010

6.4 / - / - 8.0 / - / - 4.6 / 6.1 / - 6.9 / 6.4 / - 7.7 / 6.3 / - 6.2 / 6.2 / 6.2 8.0 / 6.2 / 6.2

- 74 75 84

- 652 896 1,093 757 941

12.7 13.6 19.2 21.9 23.9 31.2 34.815 25 40

15.6 31.5 48.30.4 / - 0.9 / - 0.7 / 0.7

325

LRLEQ-AY1

GC_pre2_lowres.pdf 325 30/11/2011 12:32:05

Page 328: DAIKIN General Catalogue 2012

Model

Se

rie

s

HP Capacity** Electrical Data Condenser Dimensions Weight Sound

pressure

R-404A

-10/+32°C

R-134a

-10/+32°CPower Input

Nominal

Current

(A)

Airfl ow

(m3/h)Width (mm)

Depth

(mm)

Height

(mm)(kg)

dBA at

10m*

Med

ium

Tem

perat

ures

Low

Tem

perat

ures

* Sound pressure level measured following ISO 3744. ** Rated conditions of the refrigeration equipment: SH = 10 K; SC = 0 K

Designed for outdoor use, the condensing units are a perfect commercial refrigeration solution for cold stores or freezer rooms, small food retails, restaurants, petrol station shops, etc in low and medium temperature applications.

Main benefits › Low operation sound level › Easy to install - fully equipped - packaged › Energy efficiency and performance › Robust and reliable design

Installer benefits › Small, compact and robust for easy handling and installation in limited

space › Fully factory tested and pre-wired electrical box for quick and easy

installation and commissioning › Easy service thanks to very accessible components behind removable

robust panels › Parts and support available in the complete Daikin network

End-user benefits › Very quiet operation › Strong anti-corrosion housing for long life, even in harsh

environmental conditions › Dependable units, with proven component reliability and fully

qualified for the most demanding applications › Reduced energy consumption, thanks to efficient compressors and

condenser fan speed control (except series 1) › Fully packaged unit at a competitive price

Commercial condensing units

a Refer to condition: Outside ambient temperature= 32°C, Evaporation temperature = -10°C

(R-404A); +5°C (R-134a)

b MFA = Maximum Fuse Amps

c Sound pressure level measured according ISO 3744d refer to condensing unit charge with R-404A

e refer to condensing unit charge with R-134a

Model Series

Compressor Electrical Data Condenser Connection Receiver

Weight

(kg)

Sound

pressure

dBA at 10m

Type Swept volume

m³/h

Oil

Charge

(L)

Power Input Nominal

Current (A)Starting

Current (A)

Airflow

(m³/h)

Suction

(inch)

Liquid

(inch)

Volume

(Liter)

R-404A R-134a

JEHSCU0200M1 2 ZB15KQE-PFJ 5.9 1.24 230V/1~/50Hz 7.7 5.2 58 2,620 3/4 3/8 4.6 87.5 30.1

JEHSCU0200M3 2 ZB15KQE-TFD 5.9 1.24 400V/3~/50Hz 3.1 2.51 26 2,620 3/4 3/8 4.6 87.5 30.1

JEHSCU0250M1 2 ZB19KQE-PFJ 6.8 1.30 230V/1~/50Hz 9.6 6.24 61 2,620 3/4 3/8 4.6 89.5 31.2

JEHSCU0250M3 2 ZB19KQE-TFD 6.8 1.36 400V/3~/50Hz 4.3 2.98 32 2,620 3/4 3/8 4.6 89.5 31.2

JEHSCU0300M1 2 ZB21KQE-PFJ 8.6 1.45 230V/1~/50Hz 12.6 7.65 82 2,620 3/4 3/8 4.6 91.5 34.4

JEHSCU0300M3 2 ZB21KQE-TFD 8.6 1.45 400V/3~/50Hz 4.5 3.46 40 2,620 3/4 3/8 4.6 91.5 34.4

JEHSCU0350M3 3 ZB26KQE-TFD 9.9 1.48 400V/3~/50Hz 5.5 3.70 46 6,050 7/8 1/2 7.6 114 35.4

JEHSCU0400M3 3 ZB29KQE-TFD 11.4 1.36 400V/3~/50Hz 7.0 4.36 50 6,050 7/8 1/2 7.6 121 33.5

JEHSCU0500M3 3 ZB38KQE-TFD 14.4 2.07 400V/3~/50Hz 6.8 5.63 65.5 6,050 7/8 1/2 7.6 126 34.9

JEHSCU0600M3 3 ZB45KQE-TFD 17.1 1.89 400V/3~/50Hz 9.7 5.67 74 5,180 7/8 1/2 7.6 128 39.5

JEHSCU0680M3 3 ZB48KQE-TFD 18.8 1.80 400V/3~/50Hz 9.9 6.45 101 5,180 7/8 1/2 7.6 129 39.4

JEHCCU0050M1 1 0.5 871 - 1~/230V/50Hz 3.95 1,910 865 345 485 46 29

JEHCCU0088M1 1 0.88 1,478 - 1~/230V/50Hz 4.70 1,910 865 345 485 46 29

JEHCCU0150M1 2 1.5 2,062 1,229 1~/230V/50Hz 6.6 3,040 1,109 478 649 82 37

JEHCCU0150M3 2 1.5 2,062 1,229 3~/400V/50Hz 2.7 3,040 1,109 478 649 82 37

JEHCCU0225M1 2 2.25 3,451 1,958 1~/230V/50Hz 10.9 2,620 1,109 478 649 89 36

JEHCCU0225M3 2 2.25 3,451 1,958 3~/400V/50Hz 4.0 2,620 1,109 478 649 89 36

JEHCCU0300M1 2 3 4,506 2,948 1~/230V/50Hz 15.0 2,620 1,109 478 649 89 37

JEHCCU0300M3 2 3 4,506 2,948 3~/400V/50Hz 4.9 2,620 1,109 478 649 89 37

JEHCCU0400M3 3 4 6,527 3,925 3~/400V/50Hz 6.4 6,130 1,334 530 883 120 36

JEHCCU0500M3 3 5 8,021 4,823 3~/400V/50Hz 8.2 6,130 1,334 530 883 120 40

JEHCCU0600M3 3 6 8,897 5,860 3~/400V/50Hz 8.5 5,160 1,334 530 883 126 40

JEHCCU0675M3 3 6.75 9,756 6,153 3~/400V/50Hz 10.0 5,160 1,334 530 883 126 42

JEHCCU0825M3 4 8.25 11,010 7,083 3~/400V/50Hz 12.0 10,830 1,244 510 1,431 204 42

JEHCCU1000M3 4 10 13,528 8,667 3~/400V/50Hz 13.5 10,830 1,244 510 1,431 205 42

-30/+32°C

JEHCCU0075L1 1 0.75 562 1~/230V/50Hz 4.28 1,910 865 345 485 46 30

JEHCCU0175L1 2 1.75 1,277 1~/230V/50Hz 4.4 3,040 1,109 478 649 86 35

JEHCCU0175L3 2 1.75 1,277 3~/400V/50Hz 2.1 3,040 1,109 478 649 86 35

JEHCCU0225L1 2 2.25 2,044 1~/230V/50Hz 9.2 2,620 1,109 478 649 92 38

JEHCCU0225L3 2 2.25 2,044 3~/400V/50Hz 3.4 2,620 1,109 478 649 92 38

JEHCCU0350L3 3 3.5 2,567 3~/400V/50Hz 3.3 6,130 1,334 530 883 125 38

JEHCCU0400L3 3 4 3,757 3~/400V/50Hz 6.1 6,130 1,334 530 883 125 38

JEHCCU0725L3 4 7.25 5,549 3~/400V/50Hz 7.5 10,830 1,244 510 1,431 203 41

JEHCCU0825L3 4 8.25 7,514 3~/400V/50Hz 9.7 10,830 1,244 510 1,431 203 40

326

JEHCCU-M/L / JEHSCU-M

GC_pre2_lowres.pdf 326 30/11/2011 12:32:05

Page 329: DAIKIN General Catalogue 2012

Large variable capacity condensing unit

Length (A) Width (B) Height (C) Weight

mm mm mm kg

FromTo

A comprehensive product range with 1 or 2 compressors and 4 to 10 condenser fans › Chilled application: 113 - 417 kW

(at T0 = -10°C / Tamb = +32°C / R-404A) › Frozen application: 37 - 159 kW

(at T0 = -35°C / Tamb = +32°C / R-404A)

Designed for outdoor use, the large condensing units are a perfect medium to high capacity refrigeration solution for cold stores, distribution platforms, supermarkets, food processing, etc in low and medium temperature applications

These industrial condensing units are real workhorses designed for maximum performance in minimum space. › High energy efficiency: inverter controlled compressor,

economizer, high performance condenser › Possibility of having a stand-by compressor › Very quiet › Easy installation, ready to connect evaporators › Integrated starter and control panel with electronic controller › Approved according to EN 378-2008 (safety,

pressure, EMC and voltage directive) › Refrigerants: R-404A, R-134a, R-407C, R-507A

2,240 2,235 2,340 2,405

4,940 2,235 2,340 4,496

327

GC_pre2_lowres.pdf 327 30/11/2011 12:32:05

Page 330: DAIKIN General Catalogue 2012

GC_pre2_lowres.pdf 328 30/11/2011 12:32:05

Page 331: DAIKIN General Catalogue 2012

��

CONTROL SYSTEMS, OPTIONS & ACCESSORIES

CONTROL SYSTEMS

Remote monitoring and maintenance 330

ACNSS (Air Conditioning Network Service System) 330

Individual control systems 333

Wired remote control 333Infrared remote control 333Simplifi ed built-in remote control for hotel applications 333Simplifi ed remote control 333Online controller 334

Universal control - RTD-10, RTD-HO 336

Centralised control systems 337

Centralised remote control 337Unifi ed on/off control 337Schedule timer 337

Daikin control systems 338

338

339

340

Stadard protocol interfaces 341

Modbus interface - RTD-net 341

KNX Interface 341

342 342

OPTIONS & ACCESSORIES 343

Wireless room temperature sensor 343Wired room temperature sensor 343Other intergration devices 344

OPTION LISTS

Split 346

Sky Air 348VRV outdoor 352VRV indoor 354

Ventilation 356

Chillers 358Fan coil units 362

NEW

NEW

NEW

NEW

NEW

NEW

NEW

GC_pre2_lowres.pdf 329 30/11/2011 12:32:06

Page 332: DAIKIN General Catalogue 2012

ACNSS

AIR CONDITIONING

NETWORK SERVICE SYSTEM (ACNSS)

The challenge of your technical management is safeguarding

in the long term optimal operation of your air conditioning

system without incurring huge costs along the way. Daikin's

Air Conditioning Network Service System improves the

effectiveness of your management.

The network service system is a link via the internet, between

the air conditioning system and Daikin's Remote Monitoring

Centre. In so doing, expert service engineers monitor the

operating status of the entire system nonstop all through the

year. The 'ACNSS monitoring service' prevents troubles and

prolongs the life of your equipment.

Thanks to the prediction of malfunctions and the technical

advise following from data analysis, you not only maximise

equipment availability, but also control cost without

sacrificing comfort levels.

Daikin's ACNSS is also supported by the optional 'ACNSS

energy saving service' as energy use is one of the largest

operating expenses of any business. This service enables you

to optimise on power consumption without failing to keep

the customer's amenity.

Data

WWW.

330

GC_pre2_lowres.pdf 330 30/11/2011 12:32:06

Page 333: DAIKIN General Catalogue 2012

1 Data transmission

Air conditioners's running information and other

necessary data are collected and compiled, and

sent to the centre. Advance failure forecasts

and monitoring data for accidental problems are

transmitted.

3 data analysis

& system monitoring

Reporting data is reviewed and system is monitored

24/7 for any occurances.

Energy-saving Report

Maintenance Report

Malfunction and prediction call

Weather information

2 Daikin Remote Monitoring Centre

Daikin's control implemented

Information to customers,

service company

* A contract with Daikin is necessary for applying Energy-saving Air conditioning Network Service System. If you would like an estimation, please contact us.

energy-saving control

determination

Operating information is analyzed,

and the optimum energy-saving con-

trol settings are calculated according

to weather data for the region.

ACNSS ENERGY SAVING SERVICE

ACNSS MONITORINGSERVICE

COMFORT MAINTAINED

OPTION:

331

GC_pre2_lowres.pdf 331 30/11/2011 12:32:06

Page 334: DAIKIN General Catalogue 2012

Graphical display of indicative

electricity consumption

BRC1E52A User friendly remote control with contemporary design

A series of energy saving functions that can be individually selected › Temperature range limit › Setback function › Presence & fl oor sensor connection

(available on new round fl ow cassette) › kWh indication › Set temperature auto reset › Off timer

Temperature range limit avoids excessive heating or coolingSave energy by constraining the lower temperature limit in cooling and upper temperature limit in heating mode.

note : Also available in auto cooling/heating change over mode.

kWh indication keepstrack of your consumptionThe kWh indication shows an indicative electricity consumption of the last day/month/year.

Other functions › Up to 3 independent schedules can be set, so the user

can easily change the schedule himself throughout the year (e.g. Summer, winter, mid-season)

› Possibility to individually restrict menu functions

› Easy to use: all main functions directly accessible › Easy setup: clear graphical user interface

for advanced menu settings › Real time clock with auto update to daylight saving time › Supports multiple languages (English, German,

Dutch, Spanish, Italian, Portuguese, French, Greek, Russian, Turkish, Polish (NEW))

› Built-in backup power: when a power failure occurs all settings remain stored up to 48 hours

What’s new? Energy saving functions

NEW

IMPROVED

332

GC_pre2_lowres.pdf 332 30/11/2011 12:32:06

Page 335: DAIKIN General Catalogue 2012

Individual control systems

BRC944B2*/BRC1D52Wired remote control

› Schedule timer:• Five day actions can be set as follows:

- set point: unit is switched ON and normal operation is maintained - OFF: unit is switched OFF1

- limits: unit is switched ON and min./max. control (cf. limit operation for more details)

› Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF

› User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed

› Constantly monitoring of the system for malfunctions in a total of 80 components

› Immediate display of fault location and condition › Reduction of maintenance time and costs

Display › Operating mode1

› Heat Recovery Ventilation (HRV) in operation › Cool / heat changeover control › Centralised control indication › Group control indication › Set temperature1

› Air flow direction1

› Programmed time › Inspection test / operation › Fan speed1

› Clean air filter › Defrost / hot start › Malfunction

ARC4*/BRC4*/BRC7*Infrared remote control

Operation buttons: ON / OFF, timer mode start / stop, timer mode on / off, programme time, temperature setting, air flow direction,

operating mode, fan speed control, filter sign

reset , inspection / test indication Display: Operating mode, battery change, set temperature, air flow direction , programmed time, fan speed, inspection / test operation

1. Not applicable for FXDQ, FXSQ, FXNQ, FBDQ, FDXS, FBQ

2. For FX** units only

3. For all features of the remote control, refer to the operation manual

BRC3A61Simplified built-in remote control for hotel

applications

Compact, user friendly unit, ideal for use in hotel bedrooms

Operation buttons: ON/OFF, fan speed control, temperature setting

Display: Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode,

centralised control indication, fan speed, defrost/hot start, malfunction

BRC2C51Simplified remote control

Simple, compact and easy to operate unit, suitable for use in hotel bedrooms

Operation buttons: ON/OFF, operating mode

selection, fan speed control, temperature setting

Display: Cool/heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction adjustment, operating mode

selection, fan speed control, filter sign reset, inspection test/operation

1 Only functions marked with ‘1’ are available on BRC944B2

333

BRC3A61BRC2C51BRC4*/BRC7*ARC466A1BRC1D52 BRC944B2

GC_pre2_lowres.pdf 333 30/11/2011 12:32:07

Page 336: DAIKIN General Catalogue 2012

334

no matter where you are

Always in control, Daikin provides a new control solution to monitor and control

the main functions of the residential indoor units. The system is

working in an end-user friendly way and can be used from any

location via your smartphone, laptop, PC, tablet, app

or wired remote controller.

Residential use:Optimal home comfort / holiday home surveillance

› Create a comfortable home climate

at any time and at any place

› Remote detection of failures

Light commercial use:Flexible offi ce solution

› Dynamic group control in open space

› Fault manager / event logger

› Easily create a yearly schedule (iPlanner)

› Back-up confi guration of air conditioning

Residential* Light commercial ** Extended light commercial **

Possibility to control indoor unit via internet � � �

Possibility to control multiple indoor units via internet (up to 9 KKRP01s) � � �

Possibility to control multiple indoor units via internet (over 9 KKRP01s) � �

Filtering data OK / ERR � �

Advanced fi ltering (OK / ANY ERR / COMM ERR / AC / ERR) �

Sorting by all columns from data-grid � �

History of alerts �

History of temperatures �

History of commands �

Graphic single controller with weather forecast � � �

Text group controller � � �

Weekly planner �

I-planner (yearly schedule) � �

Receive via e-mail an alert report � � �

Autonomous periodical connectivity check �

Exceeded room temperature limits e-mail report �

Available software packages

* standard programmed on KKRP01A** Additional software to be purchased online

PC

Smartphone

Wired controller

Individual control systems Online controller

334

1

2

3

GC_pre2_lowres.pdf 334 30/11/2011 12:32:07

Page 337: DAIKIN General Catalogue 2012

Individual control systems

335

Possible indoor units:

Standard

› FTXR28-50E

› FTXG25-50J › FTXG25-35E › CTXG50J › CTXG50E › FTXS20-71G

› FTK/XS20-50D

› FTXS50-71F › FTXS20-50J › FTXL20-35G › FTX50-71GV › FTYN50-60F › FVXS25-50F

› FVXG25-50K › FLK/XS25-60C/E › ATXS20-50E

› ATXS20-50G › ATXG25-35E

Specifications

COMMUNICATION INTERFACES

Ethernet LAN 10/100 Mbit/s for connection intro LAN network

MODBUS for connection of accessories

serial S21 cable 1,3m for connection with A/C indoor unit

Power supply directly from IU - 5 V DC for Online Controller, 12 V DC for accessories

Power consumption 120 mA, 0,6 W

IP code IP10 / IP44 - inside A/C unit

OTHERS

Mounting inside of A/C IU or intro External Mounteing Kit

Weight 50g

Dimensions (W X h X d) 64 X67 X 17 mm (without cable)

Options

Online controller KKRP01A

MATERIAL NAME DESCRIPTION EXPLANATION

KKRPM01A External mounting kitTo install online controller outside the indoor unit or to extend

the length of the cable between indoor unit and KKRP01A. It can easily be mounted on the wall of hidden in false ceilings.

KKRPW01A Wifi Cable PackTo enable wireless internet connection. Wifi module to be

purchased locally.

KBRCS01A Easy wall controller Wired controller to be installed on the wall. Designed to easily

control one indoor unit or a group of indoor units.KBRC01A Touch LCD wall controller

Online controller

AppIt will be possible to control your air conditioning via an app. This app will become available for download.

335

GC_pre2_lowres.pdf 335 30/11/2011 12:32:07

Page 338: DAIKIN General Catalogue 2012

Monitor and control up to 16 VRV or Sky Air indoor units via a third party control or BMS system

RTD-10Advanced integration into BMS system of VRV,

Sky Air, VAM and VKM through either:

› Modbus

› Voltage (0-10V)

› Resistance

RTD-NETModbus interface for monitoring and control of

VRV, Sky Air, VAM and VKM

RTD-HOIntelligent hotel room controller

Energy management gateways

MAIN FUNCTIONS RTD-10 RTD-NET RTD-HO

Dimensions H x W x D mm 100 x100 x 22

Key card + window contact �Set back function �Prohibit or restrict remote control functions (setpoint limitation, ...) � � �Modbus (RS485) � � �0 - 10 V control �Resistance control �IT application �Heating interlock �Output signal (on/defrost, error) � �

CONTROL FUNCTIONS RTD-10 RTD-NET RTD-HO

On/Off M,V,R M M*

Set point M,V,R M M*

Mode M,V,R M M*

fan M,V,R M M*

Louver M,V,R M M*

HRV Damper control M,V,R M

Prohibit/Restrict functions M,V,R M M*

MONITORING FUNCTIONS RTD-10 RTD-NET RTD-HO

On/Off M M M

Set point M M M

Mode M M M

fan M M M

Louver M M M

RC temperature M M M

RC mode M M M

nbr units M M M

Fault M M M

Fault code M M M

Return air temperature (Average /Min/Max) M M M

Filter alarm M M M

Termo on M M M

Defrost M M M

Coil In/Out temperature M M M

Overview functions

Individual control systems

M: Modbus, V: Voltage, R: Resistance, *: only when the room is occupied

Universal control - RTD

336

GC_pre2_lowres.pdf 336 30/11/2011 12:32:07

Page 339: DAIKIN General Catalogue 2012

Centralised control of the VRV system can be achieved via 3 user friendly compact controls: centralised remote control, unified on/off control and schedule timer. These controls may be used independently or in combination where 1 group = several (up to 16) indoor units in combination and 1 zone = several groups in combination.A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation, enabling indoor units to be classified in groups per tenant (zoning). The schedule timer programmes the schedule and operation conditions for each tenant and the control can easily be reset according to varying requirements.

DCS302C51Centralised remote control

Providing individual control of 64 groups (zones) of indoor units.

• a maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled

• a maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate

locations• zone control

• group control• malfunction code display• maximum wiring length of 1,000m (total:

2,000m)• air flow direction and air flow rate of HRV can

be controlled• expanded timer function

DCS301B51Unified ON/OFF control

Providing simultaneous and individual control of 16 groups of indoor units.

• a maximum of 16 groups (128 indoor units) can be controlled

• 2 remote controls in separate locations can be

used

• operating status indication (normal operation, alarm)

• centralised control indication• maximum wiring length of 1,000m (total:

2,000m)

DST301B51Schedule timer

Enabling 64 groups to be programmed.

• a maximum of 128 indoor units can be

controlled• 8 types of weekly schedule • a maximum of 48 hours back up power supply• a maximum wiring length of 1,000m (total:

2,000m)

Centralised control systems

337

DST301B51DCS301B51DCS302C51

GC_pre2_lowres.pdf 337 30/11/2011 12:32:07

Page 340: DAIKIN General Catalogue 2012

Daikin control systems

FUNCTIONS

1. Monitoring FunctionsYou can monitor your air conditioning units by simply sending a text message with your mobile phone with the word “Report”: › Start/stop › Operation mode (fan/cool/heat) › Temperature setting › Error code

2 . Control FunctionsYou can control your air conditioning units by simply sending a text message via your mobile phone: › Start/stop › Operation mode (fan/cool/heat) › Temperature setting

3. Error NotificationWhen an error occurs, a text message will be sent automatically to your mobile phone (error notification).

4. Stand alone operation › Rotation function › Backup operation function.

Basic solution for control of

Sky Air and VRV

› monitoring function › control function › error notification

Mobile phone(field supply)

Up to 4 units / 1 adapter

GSM modem(field supply)

RS232C

DS-NET adapter

Daikin recommends the use of a Wavecom Fastrack modem

BRC1D52

338

GC_pre2_lowres.pdf 338 30/11/2011 12:32:08

Page 341: DAIKIN General Catalogue 2012

Daikin control systems

LANGUAGES

› English › French › German › Italian › Spanish › Dutch › Portuguese

SYSTEM LAYOUT

› Up to 2 x 64 indoor units can be controlled › Onboard Ethernet port (web

browser + e-mail) › Digital i/o contacts (option) › Touch panel (full colour

LCD via icon display)

MANAGEMENT

› Web application & internet compatibility- Monitoring & control according to user

- Remote monitoring & control of more than

one building- Remote monitoring & control of more than

one building via internet › Power Proportional Distribution:

PPD (option) › PPD data is available on the internet › Easy management of

electricity consumption › Enhanced history function

CONTROL

› Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units)

› Set back shedule › Enhanced scheduling function

(8 schedules, 17 patterns) › Flexible grouping in zones › Yearly schedule › Fire emergency stop control › Interlocking control › Increased HRV monitoring

and control function › Automatic cooling / heating change-over › Heating optimization › Temperature limit › Password security: 3 levels (general,

administration & service) › Quick selection and full control › Simple navigation

MONITORING

› Visualisation via Graphical User Interface (GUI)

› Icon colour display change function › Indoor units operation mode › Error messages via e-mail &

mobile phone (option) › Indication fi lter replacement › Multi PC

COST PERFORMANCE

› Free cooling function › Labour saving › Easy installation › Compact design: limited installation space › Overall energy saving

OPEN INTERFACE

› Communication to any third party controller (domotics, BMS, etc.) is possible via open interface

› Http option

CONNECTABLE TO

› VRV › HRV › Sky Air (via interface adapter) › Split (via interface adapter)

Detailed & easy monitoring and operation of

VRV systems

(max. 2 X 64 groups/indoor units).

Malfunction

Remote monitoring/control via internet, e-mail

PPD data is available on the internet

Onboard

Ethernet port

Links to the wattmeter when using the PPD

(option) function

Pi-port

Public line

Air conditioning Network

Service System

CSV output of PPD (option)

result

third party controller (domotics,

BMS, etc.)

Ethernet Fire alarm

DIII-NET

DIO unit

DI unit

Controls drain

pump lighting etc.

Monitoring of

room enter/

exit sign

DIII-NET Allows monitoring/control of up to

64 units (groups) of A/Cs and equipment

DIII-NET PLUS

adapter

Forced OFF contact input

HRV

HRV

Indoor units

Indoor units

RS-232C

Onboard

modem

PCMCIA

fl ash

memory

339

GC_pre2_lowres.pdf 339 30/11/2011 12:32:08

Page 342: DAIKIN General Catalogue 2012

Daikin control systems

LANGUAGES

› English › French › German › Italian › Spanish › Dutch › Portuguese

SYSTEM LAYOUT

› Up to 1,024 indoor units can be controlled (by 4 iPUs)

› Ethernet TCPIP / 10 base / T communication › Integrated digital contacts on the

Intelligent Processing Unit (iPU) - 20 general input ports - 2 digital outputs

› Stand alone operation of the iPU for minimum 48 hours

› Compatible with UPS shutdown software

MANAGEMENT

› Web access (option) › Power Proportional Distribution (option) › Operational history management (start/

stop, malfunction, operation hours) › Generation of reports (graphics &

tables) (daily, weekly, monthly) › Peak load shedding › Advanced tenant management › Sliding temperature › Eco mode (option) › Pre-cooling and -heating function

CONTROL

› Individual control (setpoint, start/stop, fan speed) (max. 1,024 indoor units)

› Group control (100 groups) › Schedule control (128 programs) › Fire emergency stop control (32 programs) › Interlocking control › Setpoint limitation › Automatic cooling/heating change-over › Power failure/release control › Temperature limit (automatic start) › Timer extension

MONITORING

› Visualisation via a Graphical User Interface (GUI) featuring free layout

› Operation mode of indoor units › Fault indication › Indication filter replacement › Setpoint indication › Operation time monitoring › Multi PC › On-line help

COST PERFORMANCE

› Labour saving › Easy installation › Compact design: limited installation space › Overall energy saving

CONNECTABLE TO

› VRV › HRV › Sky Air (via interface adapter) › Split (via interface adapter)

Full control and management of VRV systems

(Maximum 200 groups)

DIII-NET

DIII-NET

DIII-NET

Web Access

Sub PC

ET

HERN

ET

Intranet/InternetWeb Access

Malfunction report by

E-Mail

Dio unit

· Elevator· Pump· Lighting,...

Power supply facility

Ai unit

Daikin Central

Air Conditioning SystemVRV System

Local monitoring & control

Air Conditioning

Network Service System

(Optional Maintenance Service)

HRV

Electricity

MeasurementFire alarm

(Via Internet)

DAM602B51/52

DIII-N

ET

DMS502A51(monitoring only)

Windows Vista Compatible

340

~

~

GC_pre2_lowres.pdf 340 30/11/2011 12:32:08

Page 343: DAIKIN General Catalogue 2012

KLIC-DD Size 90x60x35mm KLIC-DI Size 45x45x15mm

Split Sky Air VRV

BASIC CONTROL

ON/OFF � � �Mode Auto, heat, dry, fan, cool Auto, heat, dry, fan, cool Auto, heat, dry, fan, cool

Temperature � � �Fan speed levels 3 or 5 + auto 2 or 3 2 or 3

Swing Stop or movement Stop or movement Swing or fixed positions (5)

ADVANCED FUNCTIONALITIES

Error management Communication errors, Daikin unit errors

Scenes � � �Auto switch off � � �Temperature limitation � � �Initial configuration � � �Master and slave configuration � �

Modbus interface for monitoring

and control of up to 16 VRV,

Sky Air, VAM or VKM indoor units

Standard protocol interfaces Universal control - RTD-net

Standard protocol interfaces KNX interface

Integration of Split, Sky Air and VRV

in HA/BMS systems

Domotica

Controller

shutter control

house

Co

nce

pt

Co

nce

pt

Domotica

Controller

Connect split indoor units to KNX interface for Home Automation system

Connect Sky Air / VRV indoor units to KNX interface for BMS integration

KNX interface line-upThe integration of Daikin indoor units through the KNX interface allows monitoring and control of several devices, such as lights and

shutters, from one central controller. One particularly important feature is the ability to programme a ‘scenario’ - such as “Home leave” - in

which the end-user selects a range of commands to be executed simultaneously once the scenario is selected. For instance in “Home leave” ,

the air conditioner is off, the lights are turned off, the shutters are closed and the alarm is on.

light

light

shutter control

shop

KNX interface for

To indoor unit

power supply

To indoor unit

via P1/P2

To BMS system

(modbus)

341

tv

tv

Interface Daikin protocol/ KNX

Interface Daikin protocol/ KNX

GC_pre2_lowres.pdf 341 30/11/2011 12:32:08

Page 344: DAIKIN General Catalogue 2012

Standard protocol interfaces

Open network integration of VRV monitoring and

control functions into LonWorks networks › Interface for Lon connection

to LonWorks networks › Communication via Lon

protocol (twisted pair wire) › 64 units connectable per DMS-IF › Unlimited sitesize › Quick and easy installation

LON BMS

Fire alarm

System

Security

BUILDING

CONTROL

NETWORK

adapter

LonTalk

LonTalk

LonPoint LonPoint

ET

HERN

ET

(TCP/

IP)

adapter

DMS504B51

Local Control

DIII- NET

VRV

Outdoor unit

HRV

Remote Control

DAIKIN A/C INFRASTRUCTURE

Standard protocol interfaces

› PPDdata is available on BMS system › Interface for BMS system › Communication via BACnet protocol

(connection via Ethernet) › 256 units connectable per

BACnet gateway › Unlimited sitesize › Easy and fast installation

BACN

ET

/ E

TH

ERN

ET

Fire alarm Security

Local Control

DIII- NET

VRV

Outdoor unit

Remote Control

DAIKIN A/C INFRASTRUCTURE

Power supply facility

Pump Lighting Elevator

HRV

DAM602B51/52

Integrated control system for seamless connection

between VRV and BMS systems

BUILDING

CONTROL

NETWORK

342

BACnet Interface

LonWorks Interface

GC_pre2_lowres.pdf 342 30/11/2011 12:32:09

Page 345: DAIKIN General Catalogue 2012

Wireless room temperature sensor

Flexible and easy installation

› Accurate temperature measurement thanks to fl exible placement of the sensor

› No need for wiring

› No need to drill holes

› Ideal for refurbishment

Connection diagram Daikin indoor unit PCB (FXSQ-P example)

Power supply – X35, X13

Air sensor – X16A, X19

RF SENDERRF RECEIVER

› Room temperature is sent to the indoor unit every 90 seconds or if the temperature diff erence is 0.2°C or larger.

WIRELESS ROOM TEMPERATURE SENSOR KIT (K.RSS)

WIRELESS ROOM TEMPERATURE RECEIVER WIRELESS ROOM TEMPERATURE SENSOR

Dimensions mm 50 x 50 ø 75

Weight g 40 60

Power supply 16VDC, max. 20 mA N/A

Battery life N/A +/- 3 years

Battery type N/A 3 Volt Lithium battery

Maximum range m 10

Operation range °C 0~50

CommunicationType RF

Frequency MHz 868.3

Specifications

KRCS01-1BKRCS01-4B

Wired room temperature sensor

› Accurate temperature measurement,

thanks to fl exible placement of the sensor

Dimensions (HxW) mm 60 x 50

Weight g 300

Length of branch wiring m 12

Specifications

343

K.RSS

GC_pre2_lowres.pdf 343 30/11/2011 12:32:09

Page 346: DAIKIN General Catalogue 2012

Adapter PCB’s – Simple solutions for unique requirementsOther integration devices

(E)KRP1B*

adapter for wiring

• Facilitates integration of auxiliary heating apparatus, humidifiers, fans, damper• Powered by and installed at the indoor unit

KRP2A*/KRP4A*

Wiring adapter for electrical appendices

• Remotely start and stop up to 16 indoor units (1 group) (KRP4A* via P1 P2)• Remotely start and stop up to 128 indoor units (64 groups) (KRP2A* via F1 F2) • Alarm indication/ fire shut down• Remote temperature setpoint adjustment

DTA104A*

Outdoor Unit External Control Adapter

• Individual or simultaneous control of VRV system operating mode• Demand control of individual or multiple systems• Low noise option for individual or multiple systems

Daikin’s adapter PCB’s provide simple solutions for unique requirements. They are a low cost option to satisfy simple control requirements

and can be used on single or multiple units.

Concept and benefits › Low cost option to satisfy simple control requirements

› Deployed on single or multiple units

GC_pre2_lowres.pdf 344 30/11/2011 12:32:09

Page 347: DAIKIN General Catalogue 2012

���

OPTION LISTS

Split 346

Sky Air 348VRV outdoor 352VRV indoor 354

Ventilation 356

Chillers 358Fan coil units 362

GC_pre2_lowres.pdf 345 30/11/2011 12:32:10

Page 348: DAIKIN General Catalogue 2012

INDOOR UNITS FTXR28E FTXR42E FTXR50E CTXU25G CTXU35G CTXU42G CTXU50G

Air purification and deodorising filter set without frame KAF974B42S

Air supply filter with frame KAF963A43

Suction grille

Titanium apatite photocatalytic air-purification filter without frame KAF970A47 (1)

Photocatalytic deodorising filter, with frame

Photocatalytic deodorising filter, without frame

Air purification filter, with frame

Air purification filter, without frame

Notes

(1) Standard accessory

INDOOR UNITS - CONTROL SYSTEMS FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GV *FTXS20K/CTXS15K

Wired remote control BRC944B2 BRC944B2 BRC944B2

Wiring adapter for time clock Normal open contact KRP413AA1S KRP413AB1S

Remote control Normal open pulse contact KRP413AA1S KRP413AB1S

Centralised control board Up to 5 rooms KRC72A KRC72A

Anti-theft protection for remote control KKF910A4

Cord for remote control assy3m BRCW901A03

8m BRCW901A08

Interface adapter for wired remote control KRP980B1

Central remote control DCS302CA61 DCS302CA51

Unified on/off control DCS301BA61 DCS301BA51

Schedule timer DST301BA61 DST301BA51

Interface adapter KRP980A1 (3) KRP928BA2S KRP928BB2S (3)

Notes

(1) Wiring adapter supplied by Daikin. Time clock and other devices: to be purchased locally. / (2) Wiring adapter is also required for each indoor unit. / (3) For DIII-net adapter

INDOOR UNITS FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GV *FTXS20K/CTXS15K

Anti-theft protection for remote control KKF936A4 KKF917AA4

Suction grille -

Titanium apatite photocatalytic air-purification filter without frame KAF971A42 (1) KAF952B42 KAF970A46 (1)

Cord for remote control assy (3m) BRCW901A03 BRCW901A03

Cord for remote control assy (8m) BRCW901A08 BRCW901A08

Installation leg

Notes

(1) Standard accessory

OUTDOOR UNITS RXR28E RXR42E RXR50E RX20J RX25J RX35J RX50GV RX60GV

Air direction adjustment grille KPW937A4 KPW937B4 KRP945A(A)4

Drain plug (1) KKP937A4 KKP937A4 KKP937A4

Refrigerant branch piping for twin

Extension hose set for humidification (2m) KPMH942A402

Relay joint for humidification (10pcs.) KPMJ942A4

L-shape cuffs for humidification (10pcs) KPMH950A4L

Hose for humidification (10m)(l) KPMH942A42

Hose for humidification (15m)(l)

Branch provider (2 rooms)

Branch provider (3 rooms)

Notes

(1) Standard accessory

OUTDOOR UNITS *RXS20K *RXS25K *RXLG25K *RXLG35K *RXL20J *RXL25J

Air direction adjustment grille KPW937AA4 KPW937AA4 KPW937AA4

Drain plug (1) KKP937A4 KKP937A4 KKP937A4

Refrigerant branch piping for twin

Extension hose set for humidification (2m)

Relay joint for humidification (10pcs.)

L-shape cuffs for humidification (10pcs)

Hose for humidification (10m)(l)

Hose for humidification (15m)(l)

Branch provider (2 rooms)

Branch provider (3 rooms)

Notes

(1) Standard accessory

Options & accessories - Split

INDOOR UNITS - CONTROL SYSTEMS FTXR28E FTXR42E FTXR50E CTXU25G CTXU35G CTXU42G CTXU50G

Wired remote control

Wiring adapter for time clock Normal open contact KRP413AA1S (1) KRP413AA1S (1)

Remote control Normal open pulse contact KRP413AA1S (1) KRP413AA1S (1)

Centralised control board Up to 5 rooms KRC72A (2) KRC72A (2)

Anti-theft protection for remote control KKF936A4 KKF910A4

Central remote control DCS302C51 DCS302C51

Unified on/off control DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51

Interface adapter KRP928BA2S (3) KRP928BA2S (3)

Notes

(1) Wiring adapter supplied by daikin. Time clock and other devices: to be purchased locally. / (2) Wiring adapter is also required for each indoor unit. / (3) For DIII-net adapter

346

GC_pre2_lowres.pdf 346 30/11/2011 12:32:10

Page 349: DAIKIN General Catalogue 2012

FTXG25J FTXG35J FTXG50J FDXS25E FDXS35E FDXS50C FDXS60C FVXS25F FVXS35F FVXS50F FLXS25B FLXS35B FLXS50B FLXS60B

KDGF19A45 KDGF19A45

KAF968A42 (1)

KAZ917B41

KAZ917B42

KAF925B41

KAF925B42

*FTXS25K/CTXS35K FTXS20J FTXS25J FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G FVXG25K FVXG35K FVXG50K

BRC944B2 BRC944B2 BRC944B2

KRP413AB1S KRP413AA1S (1)

KRP413AB1S KRP413AA1S (1)

KRC72A KRC72A (2) KRC72A

KKF910A4 KKF910A4

BRCW901A03

BRCW901A08

KRP980B1

DCS302CA51 DCS302CA51 DCS302CA51

DCS301BA51 DCS301BA51 DCS301BA51

DST301BA51 DST301BA51 DST301BA51

KRP928BB2S (3) KRP928BA2S (3) KRP928BB2S (3)

*FTXS25K/CTXS35K FTXS20J FTXS25J FTXS35J FTXS42J FTXS50J FTXS60G FTXS71G FVXG25K FVXG35K FVXG50K

KKF910A4w

KAF970A46 (1) KAF968A42 (1) KAF970A46 KAF970A46

BRCW901A03

BRCW901A08

BKS028

RX71GV RXS20J RXS25J RXS35J RXS42J RXS50J RXS60F RXS71F RXG25K RXG35K RXK50K 2MXU-G

KRP945A(A)4 KPW937AA4 KPW945AA4 KPW945AA4 KPW937AA4 KPW945AA4 KKPW945AA4

KKP945A4 KKP937A4 KKP937A4 KKP937A4 KKP937A4

KPMH996A10S

KPMH996A11S

*RXL35J 2MXS40H 2MXS50H *3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E

KPW937AA4 KPW945AA4 KPW945AA4 KPW945AA4

KKP937A4 KKP937A4 KKP937A4 KKP937A4

BPMKS9672B2 BPMKS9672B2

BPMKS9672B3 BPMKS9672B3

FTXG25J FTXG35J FTXG50J FDXS25E FDXS35E FDXS50C FDXS60C FVXS25F FVXS35F FVXS50F FLXS25B FLXS35B FLXS50B FLXS60B

BRC944B2 BRC944B2 BRC944B2

KRP413A1S (1) KRP413AB1S KRP413AA1S (1) KRP413AA1S (1) KRP413AA1S (1) KRP413AA1S (1)

KRP413AA1S (1) KRP413AB1S KRP413AA1S (1) KRP413AA1S (1) KRP413AA1S (1) KRP413AA1S (1)

KRC72A (2) KRC72A (2) KRC72A (2) KRC72A (2) KRC72A (2)

KKF910A4 KKF917AA4 K(K)F917AA4 KKF936A4

DCS302C51 DCS302C51 DCS302C51 DCS302C61 DCS302C51

DCS301B51 DCS301B51 DCS301B51 DCS301B61 DCS301B51

DST301B51 DST301B51 DST301B5 DST301B61 DST301B51

KRP928BA2S (3) KRP928BB2S KRP928BA2S (3) KRP928BA2S (3) KRP928BA2S (3) KRP928BA2S (3)

*Note: grey cells contain preliminary data

347

GC_pre2_lowres.pdf 347 30/11/2011 12:32:10

Page 350: DAIKIN General Catalogue 2012

Options & accessories -

INDOOR UNITS *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F *FCQG35F *FCQG50F *FCQG60F *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Replacement long-life filter KAFP551K160 KAFP551K160

Drain-up kit

L-type piping kit (upward direction)

Sealing member of air discharge outlet KDBHQ55C140 (4) KDBHQ55C140 (4)

Decoration panel for air discharge

Vertical flap kit

Decoration panel BYCQ140CW1 + BYCQ140CW1W(1) + BYCQ140CGW1 (2)(3) BYCQ140CW1 + BYCQ140CW1W (1) + BYCQ140CGW1 (2)(3)

Decoration panel option

Noise filter

Fresh air intake kit (min. 20% fresh air) KDDQ55C140 (4) KDDQ55C140 (4)

Fresh air intake kit (direct installation type)

Panel spacer

Noise filter (for electromagnetic interface only)

Notes(1) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration panel in environments exposed to concen(2) To be able to control the BYCQ140CGW1, the controller BRC1E* is needed(3) The BYCQ140CGW1 is not compatible with mini-VRV, multi and split non inverter outdoor units(4) Option not available in combination with BYCQ140CGW1(5) Decoration panel option EKBYBSD is required for direct mounting of the decoration panel of the unit.

INDOOR UNITS - CONTROL SYSTEMS *FCQHG71F *FCQHG100F *FCQHG125F *FCQHG140F *FCQG35F *FCQG50F *FCQG60F *FCQG71F *FCQG100F *FCQG125F *FCQG140F

Wired remote control BRC1E52A (4) BRC1E52A (4)

I-touch controller

Infrared remote control (heat pump) BRC7F532F (5) BRC7F532F (5)

Simplified remote control

Remote control for hotel use

Centralised remote control DCS302C51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51

Adapter for wiring

Adapter for external ON/OFF and monitoring/for electrical appendices KRP1BA57/KRP4AA53 (1)(5) KRP1BA57/KRP4AA53 (1)(5)

Interface adapter for Sky Air

Installation box for adapter PCB KRP1H98 (5) KRP1H98 (5)

Remote sensor KRCS01-4 KRCS01-4

Remote ON/OFF, forced OFF EKRORO2 EKRORO2

Electrical box with earth terminal (3 blocks)

Electrical box with earth terminal (2 blocks) KJB212AA KJB212AA

Set back time clock

Intelligent touch controller

Remote control for 2 remote control systems

Adapter for wiring (hour meter) EKRP1C11 (1)(5) EKRP1C11 (1)(5)

Options PCB for external electrical heater, humidifier and/or hour meter

External adapter for outdoor unit (installation on indoor unit)

Mounting plate for adapter PCB

Notes

(1) Installation box for adapter PCB is necessary

(2) Interface adapter for Sky Air series (DTA112BA51) is necessary

(3) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

(4) Included all the languages:English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish, Purtuguese

(5) Option not available in combination with BYCQ140CGW1

(6) When using decoration panel BYCQ140CGW1, wiring adapter (hour meter) KRP1C12 must be used

(7) When using decoration panel BYCQ140CGW, installation box for adapter PCB KRP1J98 must be used

(8) Installation box for adapter PCB(KRP4A95) is necessary

(9) Installation box for adapter PCB (KRP1BA101) is necessary

(10) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.

(11) Mounting plate KRP4A96 is required fpr these options. Maximum 2 options PCBs can be mounted.

(12) Included all the languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish. Portuguese

(13) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is requiredw

348

GC_pre2_lowres.pdf 348 30/11/2011 12:32:10

Page 351: DAIKIN General Catalogue 2012

*FFQ25B9V *FFQ35B9V *FFQ50B9V *FFQ60B9V *FBQ35C8 *FBQ50C8 *FBQ60C8 *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8 FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8

KAFQ441BA60 KAFP551K160

KDBHQ44BA60 KDBHQ55C140 (4)

BYFQ60B BYBS45D BYBS71D BYBS125D BYCQ140CW1 + BYCQ140CW1W (1) + BYCQ140CGW1 (2)(3)

EKBYBSD

KDAJ25K56A KDAJ25KA71A KDAJ25KA140A KDDQ55C140 (4)

KDDQ44XA60

KDBQ44BA60

ntrations of dirt.

*Note: grey cells contain preliminary data

*FFQ25B9V *FFQ35B9V *FFQ50B9V *FFQ60B9V *FBQ35C8 *FBQ50C8 *FBQ60C8 *FBQ71C8 *FBQ100C8 *FBQ125C8 *FBQ140C8 FMCQ50A8 FMCQ60A8 FMCQ71A8 FMCQ100A8 FMCQ125A8

BRC1E52A (12) BRC1D52/BRC1E52A (12) BRC1E52A/BRC1D52 (4)

BRC7E530W BRC4C65 BRC7F532F (5)

DCS302C51 DCS302C51 DCS302C51

DCS301B51 DCS301B51 DCS301B51

DST301B51 DST301B51 DST301B51

KRP1BA57 (9) KRP1C64 (11)

KRP4AA53 (9) KRP4A51 (11) KRP2A526/KRP4AA53 (1)(5)

DTA112BA51

KRP1BA101

KRCS01-1 KRCS01-4B KRP1H98 (5)/KRP1598 (7)

EKROROA EKRORO3 KRCS01-4

EKRP1B2A

EKRP1B2A (10)(11) KJB212AA

KRP4A96 EKRP1C11 (1)(5)/KRP1C12 (1)(6)

349

GC_pre2_lowres.pdf 349 30/11/2011 12:32:10

Page 352: DAIKIN General Catalogue 2012

Options & accessories -

OUTDOOR UNITS *RZQ(S)G71LV1 *RZQ(S)G100LV1/LY1 *RZQ(S)G125LV1/LY1 *RZQ(S)G140LV1/LY1

Air direction adjustment grille

Central drain plug

Refrigerant branch piping

For twin

For triple

For double twin

Demand adapter kit

Notes

(1) For RZQ100-140B9W1 in combination FCQH71D8, use the refrigerant branch piping mentioned between brackets.

INDOOR UNITS - CONTROL SYSTEMS FDQ125C FDQ200B FDQ250B *FAQ71C *FAQ100C *FAQ125C *FHQG35C *FHQG50C *FHQG60C *FHQG71C *FHQG100C *FHQG125C

Wired remote control BRC1D52/BRC1E52A(12) BRC1E52A / BRC1E71 / BRC1D52 BRC1E52A (4)

I-touch controller DCS601CS1

Infrared remote control (heat pump) BRC7EB518 BRC7EA63W

Simplified remote control

Remote control for hotel use

Centralised remote control DCS302C51 DCS302CA51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301BA51 DCS301B51

Schedule timer DST301B51 DST301BA51 DST301B51

Adapter for wiring KRP1BA54 KRP4AA51 KRP1BA54

Adapter for external ON/OFF and monitoring/for electrical appendices KRP4AA51 KRP4AA52(1)

Interface adapter for Sky Air (2) DTA112BA51 DTA112BA51

Installation box for adapter PCB KRP4AA93 KRP1CA93

Remote sensor KRCS01-1A KRCS01-1A

Remote ON/OFF, forced OFF EKRORO KJB311AA EKROROA

Electrical box with earth terminal (3 blocks) KJB312AA KJB311AA

Electrical box with earth terminal (2 blocks) KJB212AA

Set back time clock

Intelligent touch controller DCS601C51

Remote control for 2 remote control systems

Adapter for wiring (hour meter) (3)

Options PCB for external electrical heater, humidifier and/or hour meter EKRP1B2A

External adapter for outdoor unit (installation on indoor unit)

Mounting plate for adapter PCB

Notes

(1) Installation box for adapter PCB is necessary

(2) Interface adapter for Sky Air series (DTA112BA51) is necessary

(3) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment.

(4) Included all the languages:English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish, Purtuguese

(5) Option not available in combination with BYCQ140CGW1

(6) When using decoration panel BYCQ140CGW1, wiring adapter (hour meter) KRP1C12 must be used

(7) When using decoration panel BYCQ140CGW, installation box for adapter PCB KRP1J98 must be used

(8) Installation box for adapter PCB(KRP4A95) is necessary

(9) Installation box for adapter PCB (KRP1BA101) is necessary

(10) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.

(11) Mounting plate KRP4A96 is required fpr these options. Maximum 2 options PCBs can be mounted.

(12) Included all the languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish. Portuguese

(13) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required

INDOOR UNITS FDQ125C FDQ200B FDQ250B *FAQ71C *FAQ100C *FAQ125C *FHQG35C *FHQG50C *FHQG60C *FHQG71C *FHQG100C *FHQG125C

Replacement long-life filter KAF501DA56 KAF501DA80 KAF501DA80 KAF501DA112 KAF501DA160

Drain-up kit K-KDU572EVE KDU50N60VE KDU50N125VE

L-type piping kit (upward direction) KHFP5MA35 KHFP5MA63 KHFP5MA160

Sealing member of air discharge outlet

Decoration panel for air discharge

Vertical flap kit

Decoration panel BYBSK5D

Decoration panel option EKBYBSD

Noise filter KEK26-1A

Fresh air intake kit (min. 20% fresh air) KDAJ25K140A

Fresh air intake kit (direct installation type)

Panel spacer

Noise filter (for electromagnetic interface only)

Notes(1) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration

panel in environments exposed to concentrations of dirt.

(2) To be able to control the BYCQ140CGW1, the controller BRC1E* is needed

(3) The BYCQ140CGW1 is not compatible with mini-VRV, multi and split non inverter outdoor units

(4) Option not available in combination with BYCQ140CGW1

(5) Decoration panel option EKBYBSD is required for direct mounting of the decoration panel of the unit.

350

GC_pre2_lowres.pdf 350 30/11/2011 12:32:10

Page 353: DAIKIN General Catalogue 2012

AZQS71AV1/AW1 AZQS100AV1/AW1 AZQS125AV1/AW1 AZQS140AV1/AW1 RZQ200C RZQ250C CMSQ200A CMSQ250A

EKDK04 KWC26B280 KWC26B160 KWC26B280

KHRQ22M20TA KHRQ22M29H

KHRQ250H7 KHRQ22M20T

KHRQ22M20TA(x3)

KRP58M51 KRP58M51

*Note: grey cells contain preliminary data

FHQ35B FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B FUQ71B FUQ100B FUQ125B *FVQ71C *FVQ100C *FVQ125C *FVQ140C *FMDQ50B *FMDQ60B *FMDQ71B *FMDQ100B *FMDQ125B

BRC1E52A/BRC1D52 (4) BRC1E52A (4) BRC1E52A / BRC1E71 / BRC1D52 BRC1D52/BRC1E52A (12)

DCS301BAS1

BRC7EA63W BRC7CA528W BRC4C65

BRC2C51

BRC3A61

DCS302C51 DCS302CA51 DCS302CA51 DCS302C51

DCS301B51 DCS301BA51 DCS301BA51 DCS301B51

DST301B51 DST301BA51 DST301BA51 DST301B51

KRP1BA54 KRP4AA52

KRP4AA52(1) KRP4AA53(1) KRP2A51 (10) (11) (13) /KRP4A51 (11) (13)

DTA112BA51 DTA112BA51

KRP1CA93 KRP1BA97 KRP4AA95

KRCS01-1A KRCS01-1A KRCS01-4B

EKROROA EKROROA

KJB311AA KJB311AA KJB311A

KJB212AA KJB212AA KJB212A

DCS601C51

EKRP1B2A (10) (11) (13)

DTA104A61 (11)

KRP4A96

FHQ35B FHQ50B FHQ60B FHQ71B FHQ100B FHQ125B FUQ71B FUQ100B FUQ125B *FVQ71C *FVQ100C *FVQ125C *FVQ140C *FMDQ50B *FMDQ60B *FMDQ71B *FMDQ100B *FMDQ125B

KAF501DA56 KAF501DA80KAF501DA80 KAF501DA112 KAF501DA160 KAF495FA140 KAFJ95L160

KDU50N60VE KDU50N125VE

KHFP5MA35 KHFP5MA63 KHFP5MA160 KHFP49MA140

KDBH49FA80 KDBH49FA140

KDBT49FA80 KDBT49FA140

KDGJ49FA80 KDGJ49FA140

BYBS45D (5) BYBS71D (5) BYBS125D (5)

EKBYBSD

KDAJ25K56A KDAJ25K71A KDAJ25K140A

351

GC_pre2_lowres.pdf 351 30/11/2011 12:32:10

Page 354: DAIKIN General Catalogue 2012

Options & accessories - outdoor

VRV OUTDOOR UNITS

VRV air cooled outdoor systems

VRVIII heat recovery (high COP and small footprint combination) VRVIII heat recovery, with connection to heating only hydrobox

VRV-Q heat recovery replacement VRV

VRVIII heat pump optimised for heating

REYQ8P9 REYQ12P9 REMQ8P9 REMQ14-16P8 REYQ18-48P8/P9 RQ(C)EQ-P RTSYQ14P

REYQ10P8 REYQ14-16P8 REMQ10P8 REMQ12P9 REMHQ12P9 REYHQ16-24P REYAQ10P REYAQ12P REYAQ14P REYAQ16P RTSYQ10P RTSYQ16P RTSYQ20P

Cool/heat selector

Fixing box KJB111A

REFNET header

KHRQ23M29H KHRQ23M29H KHRQ(M)22M29H KHRQ22M29H 8

KHRQ23M64H KHRQ23M64H KHRQ(M)22M64H KHRQ22M64H

KHRQ23M75H KHRQ(M)23M29H

REFNET joint

KHRQ23M20T KHRQ(M)23M64H KHRQ22M20T

KHRQ23M29T9 KHRQ(M)22M75H KHRQ22M29T9

KHRQ23M64T KHRQ23M64T KHRQ(M)22M20T KHRQ22M64T

KHRQ23M75T KHRQ(M)22M29T9Outdoor unit multi piping con-

nection kit

For 2 outdoor units BHFQ23P907 KHRQ(M)22M64T BHFP26P36C BHFQ22P1007

For 3 outdoor units BHFQ23P1357 KHRQ(M)22M75T BHFP26P63C

For 4 outdoor units KHRQ(M)23M75H BHFP26P84C

Central drain pan kit KWC25C450 2 KWC26C280 2 KWC2@6C450 2 10 KHRQ(M)23M20T

Drain pan heater kit BEH22A10Y1L/N/U / BEH22A18Y1L/N/U

Digital pressure gauge kit BHGP26A13 KHRQ(M)23M29T9Increase height difference

between indoor & outdoor to 90mKHRQ(M)23M64T

BS Box for H/R BSVQ100P, BSVQ160P, BSVQ250P KHRQ(M)23M75T

Central BS Box for H/R BSV4Q100PV

Sound reduction kit for BSVQ Box EKBSVQLNP 4

BP Box for connection to stylish

indoor units KWC25C450

Wind

cover 11

Full set KPS25C450 5 KPS26C280 5 KPS26C504 5 10 BHGP26A1

Top/discharge KPS25C450T 5 KPS26C280T 5 KPS26C504T 5 10

Rear/suction KPS25C450B 5 KPS26C280B 5 KPS26C504B 5 10 BSVQ100P8V1B, BSVQ160P8V1B, BSVQ250P8V1B2

Left/suction KPS26C504L5 BSV4Q100PV1, BSV6Q100PV1 2

Right/suction KPS26C504R 5 EKBSVQLNP 4

Snowbreak

hood 11

Kit (inlet + outlet) KPS26C280 9 KPS26C504 9 KPS26C280X2 9

Air outlet KPS26C280T 9 KPS26C504T 9 KPS26C280TX2 9

Left side air inlet KPS26C504L9 KPS26C504LX2 9

Right side air inlet KPS26C504R 9 KPS26C504RX2 9

Back side air inlet KPS26C280B 9 KPS26C504B 9 KPS26C280BX2 9

VRV OUTDOOR UNITS VRV-WIII standard series - heat recovery

RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P

Cool/heat selector

Fixing box KJB111A

REFNET header

KHRQ23M29H

KHRQ23M64H

KHRQ23M75H

REFNET joint

KHRQ23M20T/KHRQ23M29T

KHRQ23M64T

KHRQ23M75T

Outdoor unit multi piping connec-tion kit

For 2 outdoor units BHFP26MA56

For 3 outdoor units BHFP26MA84

Strainer kitBWU26A15

BWU26A20

External control adapter for outdoor unit DTA104A62

BS Box for H/R BSVQ100P8, BSVQ160P8, BSVQ250P8

Central BS Box for H/R BSV4Q100PV, BSV6Q100PV

Notes

(1) All options are kits

(2) Central drain pan kit shall be combined based on the outdoor multi connection table

(3) Only 1 option per installation is needed

(4) Only available for standard BSVQ boxes (not possible for central BSVQ). Allows to reduce operating sound of BSVQ box (requires 1 sound kit per BSVQ box)

(5) Only required for technical cooling (outdoor temperature <5°C). For more information contact your local dealer

(6) 1 Option per module is required

(7) The option should be installed inside the outdoor unit, only needed in case outdoor unit is installed above indoor

(8) Ø 25.4 Gas pipe in KHRQ22M29H is not available for DENV refnet. This is only required for the 10HP model using size uo AND with an indoor connection ratio of less than 80%

(9) Snowbreak hoods are field supply. For technical drawings and more information contact your local Daikin dealer. Snowbreak hoods are advised to be installed when regular snowfall occurs.

(10) To be combined based on the outdoor multi table.

(11) Field supply only

352

GC_pre2_lowres.pdf 352 30/11/2011 12:32:10

Page 355: DAIKIN General Catalogue 2012

VRV air cooled outdoor systems

VRVIII heat pump (high COP and small footprint combination) / VRVIII heating only VRVIII heat pump with connection to stylish indoor units VRVIII-S heat pump VRV-Q heat pump

replacement VRVRXYQ8P9RXHQ8P

RXYQ20-54P9RXHQ20-54P

RXYQ5P9 RXYQ10P9RXHQ10P

RXYQ12P9RXHQ12P RXYHQ12P9 RXYQ14-18P9

RXHQ14-18P RXYHQ16-36P9 RXYRQ8-10P RXYRQ12P RXYRQ14-18P RXYSQ4P8V1/RXYSQ4P8Y1

RXYSQ5P8V1/RXYSQ5P8Y1

RXYSQ6P8V1/RXYSQ6P8Y1 RQYQ-P

KRC19-26A6 KRC19-26A6 KRC19-26A6 KRC19-26A6

KJB111A KJB111A KJB111A KJB111A

KHRQ22M29H KHRQ22M29H KHRQ22M29H

KHRQ22M64H KHRQ22M64H

KHRQ22M75H

KHRQ22M20T KHRQ22M20T KHRQ22M20T

KHRQ22M29T9 KHRQ22M29T9

KHRQ22M64T KHRQ22M64T

KHRQ22M75T

BHFQ22P1007 BHFQ22P1007

BHFQ22P1517

KWC26B160 KWC26B280 KWC26B450 2 KWC26B280 KWC26B450 KKPJ5F180

BHGP26A1 3 BHGP26A1

EKLD90P12 EKLD90P18 6/7

BPMKS967B2

BPMKS967B3

VRV water cooled outdoor systems

VRV-WIII standard series - heat pump VRV-WIII geothermal series - heat recovery

VRV-WIII geothermal series - heat pump

RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P RWEYQ8PR RWEYQ10PR RWEYQ8PR RWEYQ10PR

KRC19-26A5 KRC19-26A

KJB111A KJB111A KJB111A

KHRQ22M29H KHRQ23M29H KHRQ22M29H

KHRQ22M64H

KHRQ22M75H

KHRQ22M20T/KHRQ22M29T KHRQ23M20T KHRQ22M20T

KHRQ22M64T KHRQ23M29T9 KHRQ22M29T

KHRQ22M75T

BHFP22MA56

BHFP22MA84

BWU26A15 BWU26A15 BWU26A16

BWU26A20 BWU26A20 BWU26A21

DTA104A62 DTA104A62

BSVQ100P8, BSVQ160P8, BSVQ250P8

BSV4Q100PV, BSV6Q100PV

*Note: grey cells contain preliminary data

353

GC_pre2_lowres.pdf 353 30/11/2011 12:32:11

Page 356: DAIKIN General Catalogue 2012

Options & accessories - indoor

Notes:

(1) Filter chamber is required when installing a high efficiency filter (2) To be able to control the BYCQ140CGW1, wired remote control BRC1E52A is needed

(3) The BYCQ140CW1W has white insulations. Be informed that information of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140CW1W decoration panel in environments exposed to

concentrations of dirt. (4) Option not available in combination with BYCQ140CGW1

Notes:

(1) Installation box is required (2) Fixing box is KRP1A90 (3) Mounting plate KRP4A96 is required. Maximum 2 option PCB can be mounted

(4) Up to 2 adapters can be fixed per installation box (5) Only 1 installation box can be installed per indoor unit (6) For output 4 signals: Hour meter, fan, auxiliary electric heater, humidifier(7) For output 2 signals: Hour meter, fan (8) Option not available in combination with BYCQ140CGW1 (9) This kit contains parts to connect with 10 multi tenant indoor units(10) Included languages are English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian & Turkish (11) Both options needed

OTHERS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Wiring adapter 6 KRP1B57 1 KRP1B61 KRP1B61

Wiring adapter 7 EKRP1C11 1/8 EKRP1B2 EKRP1B2

Wiring adapter for control and monitoring of F1 F2 KRP2A526 1/8 KRP2A52 1 KRP2A51 1 KRP2A61 KRP2A51

Wiring adapter for control and monitoring of P1 P2 KRP4A53 1/8 KRP4A53 1 KRP4A51 1 KRP4A51 KRP4A51

Remote sensor KRCS01-4 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1

Installation box / mounting plate for adapter PCB KRP1H98 8 KRP1BA101 KRP1B96 4/5

Electrical box with earth terminal (3 blocks) KJB311A KJB311A KJB311A KJB311A

Electrical box with earth terminal (2 blocks) KJB212A KJB212A KJB212A KJB212A KJB212A

External control adapter (for C/H zone, input LNO & Demand) DTA104A52 DTA104A51 1 DTA104A61 DTA104A61

Interface adapter to connect indoor to F1 F2

Connector for forced on/forced off

Multi tenant option DTA114A61 3/8 EKMTAC 9 EKMTAC 9

INDIVIDUAL CONTROL SYSTEMS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Wired remote control BRC1E52A 10 / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A 10/ BRC1D52 BRC1E52A 10 / BRC1D52 BRC1E52A 10 / BRC1D52

Infrared remote control Heat pump BRC7F532F 8 BRC7E530 BRC7C62 BRC4C61 BRC4C62

Simplified remote control BRC2C51

Simplified remote control for hotel use BRC3A61

CENTRALISED CONTROL SYSTEMS FXFQ FXZQ FXCQ FXKQ FXDQ-M9

Centralised remote control DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51 DST301B51 DST301B51 DST301B51

FXFQ20-63P9 FXFQ80-125P9 FXZQ20-50M9 FXCQ20-32M8 FXCQ40-50M8 FXCQ63M8

Decoration panel BYCQ140CW1 / BYCQ140CW1W 3/ BYCQ140CGW1 2 BYFQ60B BYBC32G BYBC50G BYBC63G

Decoration panel option

Replacement long life filter (non-woven type) KAFP551K160

Fresh air intake kit (20% fresh air intake)(chamber type) KDDQ55C140-1 4/ KDDQ55C140-2 4

Fresh air intake kit (direct installation type) KDDQ44XA60

Sealing member of air discharge outlet KDBHQ55C140 4 KDBH44BA60

Panel spacer KDBQ44B60

Replacement long life filter

High efficiency filter 65%

High efficiency filter 90%

Filter chamber for bottom suction

Air discharge grille

Air discharge blind panel

Flexible duct (with shutter)

Insulation kit for high humidity

Air discharge adapter for round duct

FXMQ20-25-32P7 FXMQ40P7 FXMQ50-63P7 FXMQ80P7 FXMQ100-125P7 FXMQ200-250MA FXAQ15-63P FXHQ32MA

Decoration panel BYBS32D BYBS45D BYBS71D BYBS71D BYBS125D

Decoration panel option EKBYBSD

Rear decoration panel

Sealing member of air discharge outlet

Replacement long life filter KAFJ371L280

High efficiency filter 65%

High efficiency filter 90%

Filter chamber

Air discharge adapter for round duct KDAJ25K36A KDAJ25K56 KDAJ25K71 KDAJ25K140

Drain pump kit K-DU572EVE KDU50M60VE

Replacement long life filter (resin net)

L-type piping kit (for upward direction)

Air discharge decoration panel

Vertical flap kit

354

GC_pre2_lowres.pdf 354 30/11/2011 12:32:11

Page 357: DAIKIN General Catalogue 2012

FXDQ-P7 FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

KRP1B56 KRP1C64 KRP1C64 3 KRP1B61 KRP4A53 KRP1B3 KRP1B61 KRP1B61

EKRP1B2A 3 EKRP1B2A 3

KRP2A53 KRP2A51 KRP2A51 3 KRP2A61 KRP2A51 1 KRP2A62 1 KRP2A51 KRP2A51

KRP4A54 KRP4A51 KRP4A51 3 KRP4A51 KRP4A51 1 KRP4A52 1 KRP4A51 KRP4A51

KRCS01-1 KRCS01-4B KRCS01-4 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1 KRCS01-1

KRP1BA101 KRP4A96 4 /5 KRP4A96 4/5 KRP4A93 4/5 KRP1B97 KRP1C93 4

KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A KJB311A

KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A KJB212A

DTA104A53 DTA104A61 DTA104A61 DTA104A61 DTA104A61 DTA104A62 DTA104A61 DTA104A61

DTA102A52

EKRORO

EKMTAC 9 DTA104A61 3 DTA114A61 DTA114A61 EKMTAC 9 EKMTAC 9

FXDQ-P7 FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

BRC1E52A 10 / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52

BRC4C65 BRC4C65 BRC4C66 BRC4C65 BRC7E618 BRC7C528 BRC7E63 BRC4C65 BRC4C65

BRC2C51 BRC2C51 BRC2C51 BRC2C51 BRC2C(A)51 BRC2C51

BRC3A61 BRC3A61 BRC3A61 BRC3A61 BRC3A61 BRC3A61

FXDQ-P7 FXSQ FXMQ-P7 FXMQ-MA FXAQ FXUQ FXHQ FXLQ FXNQ

DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51 DCS302C51

DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51 DCS301B51

DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51 DST301B51

FXCQ80-125M8 FXKQ25-40MA FXKQ63MA FXDQ20-25M9 FXDQ20-32P7 FXDQ40-50P7 FXDQ63P7 FXSQ20-32P FXSQ40-50P FXSQ63-80P FXSQ100-140P

BYBC125G BYK45F BYK71F BYBS32D BYBS45D BYBS71D BYBS125D

EKBYBSD

KDT25N32 KDT25N50 KDT25N63

KDAJ25KA36A KDAJ25KA56 KDAJ25KA71 KDAJ25KA140

FXHQ63MA FXHQ100MA FXUQ71MA FXUQ100MA FXUQ125MA FXLQ20-25P FXLQ32-40P FXLQ50-63P FXNQ20P FXNQ25P FXNQ32P FXNQ40P FXNQ50P FXNQ63P

EKRDP25A EKRDP40A EKRDP63A

KDBHJ49F140

KDU50M125VE KDU50M125VE

355

GC_pre2_lowres.pdf 355 30/11/2011 12:32:11

Page 358: DAIKIN General Catalogue 2012

Options & accessories - ventilation

OTHERS VAM-FA VKM-GA(M)

Wiring adapter for electrical appendices (control and monitoring F1 F2) KRP2A61 KRP2A61

Wiring adapter for electrical appendices (control and monitoring P1 P2)

Adapter for humidifier (running ON signal output) KRP50-2 KRP50-2

Adapter for heater control kit BRP4A50 BRP4A50

Remote sensor

Notes

(1) Cool/heat selector required for operation

(2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface…).

OTHERS VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA

High efficiency filter -65%

-90%

Replacement long life filter

Filter chamber 1

SilencerNom. piping diameter

Duct adapterNom. piping diameter

Drain pump kit

Adapter for wiring

Central drain pan

Central drain plug

Cool/heat selector

Fixing box

Notes

(1) Filter chamber has a suction-type flange. (Main unit does not).

Some options may not be usable due to the equipment installations conditions. Please conrfirm prior to ordering.

Some options may not be used in combination.

Operating sound may increase somewhat depending on the options used.

INDIVIDUAL CONTROL SYSTEMS VAM-FA VKM-GA(M)

Wired remote control BRC1E52A / BRC1D52 BRC1E52A / BRC1D52

VAM wired remote control BRC301B61

CENTRALISED CONTROL SYSTEMS VAM-FA VKM-GA(M)

Centralised remote control DCS302C51 DCS302C51

Unified ON/OFF control DCS301B51 DCS301B51

Schedule timer DST301B51 DST301B51

356

GC_pre2_lowres.pdf 356 30/11/2011 12:32:11

Page 359: DAIKIN General Catalogue 2012

FXMQ-MF EKEQFCB 2 EKEQDCB 2 EKEQMCB 2

KRP2A61

KRP4A51 KRP4A51

KRCS01-1

VAM1000FA VAM1500FA VAM2000FA VKM50GA(M) VKM80-100GA(M) FXMQ125MF FXMQ200-250MF ERQ100-125AV1 ERW140AV1 ERQ125AW1 ERQ200-250AW1

KAFJ371L140 KAFJ371L280

KDJ3705L280

KDDM24B100

ø250mm

KRP1B61

KWC26B160 KWC26B280

KKPJ5F180 KKPJ5F180

KRC19-26A6

KJB111A

FXMQ-MF EKEQFCB 2 EKEQDCB 2 EKEQMCB 2

BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 BRC1E52A / BRC1D52 1 BRC1E52A / BRC1D52 1

FXMQ-MF EKEQFCB 2 EKEQDCB 2 EKEQMCB 2

DCS302C51

DCS301B51

DST301B51

357

GC_pre2_lowres.pdf 357 30/11/2011 12:32:11

Page 360: DAIKIN General Catalogue 2012

Options - chillers

Description codeEWAQ~BAEWYQ~BA

EWAD-BZEWYD-BZ

EWAD~CZ EWAD~CF EWWQ~B- EWAD~D- EWAD~E- ERAD~E-EWWD~G-XSEWWD~G-SS

EWLD~G-SSEWWD~I-XSEWWD~I-SS

EWLD~I-SS EWWD~FZXS EWAD~C-EWWD-J-SSEWLD-J-SS

EWWD~H-

Total heat recovery 01 Option Option Option (1) Option Option Option Option (9) OptionTotal heat recovery 1 circuit 02 Option Option (1)Partial heat recovery 03 Option Option Option Option (1) Option Option Option Option Option OptionDirect on line starter 04

Wye delta starter (y - d) 05 STD STD STD STD STD STD STD STD STD STD STD STDSoft starter 06 Option Option Option Option Option Option Option Option Option Option CF OptionHeat pump version 07 Option Option Option OptionBrine version 08 Option Option Option Option Option Option Option Option Option Option Option Option Option OptionDouble set point 10 STD STD STD STD STD STD STD STD STD STD STD STD STD STDCompressor thermal relays 11 STD Option Option Option Option Option Option Option Option Option OptionFans circuit breakers with thermal overload relays 12 STD STD STD STD STDPhase monitor 13 STD STD STD STD STD STD STD STD STD STD STD STD STD STDInverter compressor starter 14 STD STD STD CF

Under / overvoltage control 15 Option Option Option Option Option Option Option Option Option Option Option Option Option OptionEnergy meter 16 Option Option Option Option Option Option Option Option Option Option Option Option Option Option OptionCapacitors cosfi 0.9 17 Option Option Option Option Option Option Option Option Option Option Option OptionCurrent limit - display 19 Option Option Option Option Option Option Option Option Option Option Option STD Option Option OptionEvaporator victaulic kit 20 STD STD STD STD (2) STD STD STD STD STD STD STD STDEvaporator flange kit 21 Option STD Option (2) Option OptionEvaporator Marine WaterBox VICTAULIC (1 Pass) 22a OptionEvaporator marine waterbox victaulic (2 step) 22 OptionEvaporator marine waterbox victaulic (3 step) 23 OptionEvaporator Marine WaterBox FLANGED (1 Pass) 24a Option OptionEvaporator marine waterbox flanged (2 step) 24 Option OptionEvaporator marine waterbox flanged (3 step) 25 Option OptionCondenser double flanges kit 26 Option Option Option Option OptionEvaporator water side design pressure 10 bar 27 STD STD STD STD STD STD STD STDEvaporator water side design pressure 25 bar 28 Option Option Option20 mm evaporator insulation 29 Option STD STD Option Option (2) Option Option Option Option Option STD STD STD STDAxial fans 100 pa lift 30 CF

Axial fans 250 pa lift 32 CF

20mm condenser insulation 33 Option Option Option Option Option Option OptionFan silent mode 34 STD (14) OptionFans speed control device (phase cut on fan) 35 STD (15) CF

Condenser victaulic kit 36 Option Option Option Option STD STD (17) STDCondenser flange kit 37 OptionCondenser Marine WaterBox VICTAULIC (1 Pass) 38a Option OptionCondenser Marine WaterBox VICTAULIC (2 Passes) 38 Option OptionCondenser Marine WaterBox VICTAULIC (3 Passes) 39 Option OptionCondenser Marine WaterBox FLANGED (1 Pass) 40a Option OptionCondenser Marine WaterBox FLANGED (2 Passes) 40 Option OptionCondenser Marine WaterBox FLANGED (3 Passes) 41 Option OptionSpeedtrol

(fan speed control device - on/off - up to -18°c)42 Option Option

Option

(3)Option Option Option

Condenser coil guards 43 Option Option Option Option Option Option OptionEvaporator area guards 44 Option Option Option CF

Cu-cu condenser coil 45 Option Option Option Option Option Option OptionCu-cu sn condenser coil 46 Option Option Option Option Option Option OptionCondenser water side design 16 bar 47 STD STD STD STD STD (1) STDCondenser water side design 21 bar 48 OptionAlucoat fins coil 49 Option Option Option Option Option Option OptionCu-ni 90-10 condenser tubes 50 Option Option Option Option Option

1. Heat exchangers are placed in series2. Please note the following option availability: - Group 1: EWAD180-200D-SL; EWAD180-190D-SR; EWAD210D-SX; EWAD200-210D-HS - Group 2: all other models Group 1 Group 2 Option 20 N/A STD Option 21 N/A Option Option 29 STD Option3. Option 42 is ‘N/A’ for EWAD-D-SX version

Nomenclature for air-cooled B and C series:

E W A D 4 6 0 B Z X S1 2 3 4 5 6 7 8 9 10 11

9 Inverter

-: non-inverter

Z: inverter

10 Efficiency level

S: Standard

X: High

P: Premium

11 Sound level

S: Standard

L: Low

R: Reduced

(s) OP12 & OP03 need to be added to meet Swedish national law 1992: 16

(1) Impossible option combination: OPZH+OPZL

(2) Not available with option OPLN

4. Option 56 is ‘STD’ for EWAD180-200D-SL; EWAD180-190D-SR; EWAD200-210D-HS5. One ‘High pressure side manometer’ per circuit6. * Low lift 8m – high lift 12m (nominal condition) * Option 80/81 is ‘N/A’ for EWAD180-190D-SR; 78/79/80/81 is ‘N/A’ for EWAD-D-SX version7. Option 99 is ‘STD’ for EWAD-D-SX version8. Not available for 2 smallest models9. Not available for high efficiency range

10. Tank delivered separately

11. Not available for standard efficiency range13. Only available for EWAD~BZ range14. Fan silent mode is an option for EWYD~BZSS15. Only for EWYD~BZSL, option for EWYD~BZSS16. Not available for EWYD~BZ17. Not available for condenserless range18. Only available for condenserless range* Option 76 is standard available for the versions with reduced / extra low sound level

Type Compr. Refr Mode Reference Products

Integrated Hydronics

Single pump contact

Twin pump contact Single pump Twin pump High ESP pump

OPSC OPTC OPSP OPTP OPHP

Air Coo

led

SWING R-410AEWAQ-ACV3 005-006-007 STDEWYQ-ACV3 005-006-007 STD

SCROLL

R-410A

EWAQ-ACV3 009-010-011 STDEWAQ-ACW1 009-011-013 STDEWYQ-ACV3 009-010-011 STDEWYQ-ACW1 009-011-013 STD

R-407C

EUWAC-FBZW1 5-8-10EUWAN-KBZW1 5-8-10-12-16-20-24

EUWAP-KBZW1 5-8-10-12-16-20-24 •

EUWAB-KBZW1 5-8-10-12-16-20-24 •

EUWYN-KBZW1 5-8-10-12-16-20-24

EUWYP-KBZW1 5-8-10-12-16-20-24 •

EUWYB-KBZW1 5-8-10-12-16-20-24 •

R-410AEWAQ-DAYNN 080-100-130-150-180-210-240-260 • • • • •

EWYQ-DAYNN 080-100-130-150-180-210-240-260 • • • • •

Water

Coo

led

SCROLL R-407C EWWP-KBW1N 014-022-028-035-045-055-065

Cond

en-

serle

ss

chiller

SCROLL R-407C EWLP-KBW1N 012-020-026-030-040-055-065

358

GC_pre2_lowres.pdf 358 30/11/2011 12:32:11

Page 361: DAIKIN General Catalogue 2012

Noise & Head Pressure Control LWE Electrical Refrigerant Condenser

Buffer tank Low noise Inverter fans High ESP fans High Glycol Low GlycolEvaporator heater tape

Main switch A / V meter Dual pressure

relief valveSuction stop

valve Coil guards

OPBT OPLN OPIF OPHF OPZH OPZL OP10 OP52 OP57 OP03 OP12 OPCG

STDSTDSTDSTDSTDSTD

• •

• • • •

• • • •

STD • • • •

• • • •

• • • •

STD • • • •

• • •(2) • • STD • • •(s) •

• • •(2) • • STD • • •(s) •

• •

• •

Description codeEWAQ~BAEWYQ~BA

EWAD-BZEWYD-BZ

EWAD~CZ EWAD~CF EWWQ~B- EWAD~D- EWAD~E- ERAD~E-EWWD~G-XSEWWD~G-SS

EWLD~G-SSEWWD~I-XSEWWD~I-SS

EWLD~I-SS EWWD~FZXS EWAD~C-EWWD-J-SSEWLD-J-SS

EWWD~H-

Condenser 1 pass (dt 4-8 °c) 51 STD (9) Option OptionCondenser 2 passes (dt 4-8 °c) 52 STD (11) STD (17) STDCondenser 2 passes (dt 9-15 °c) 53 Option (9) STDCondenser 3 passes 53b Option OptionCondenser 4 passes 54 OptionWater pressure differential switch on condenser 55 Option STDWater pressure differential switch on evaporator 56 Option (4) Option Option STD OptionEvaporator electric heater 57 Option STD STD Option STD STD STDEvaporator flow switch 58 Option Option Option Option Option Option Option Option Option Option Option Option STD OptionCondenser flow switch 59 Option Option Option OptionElectronic expansion device 60 STD STD STD STD STD STD STD STD STD STD STD STD STD STDDischarge line shut off valve 61 STD STD STD Option STD STD STD Option Option STD STD STDSuction line shut off valve 62 STD Option Option Option STD STD STD STD STD Option Option Option STD OptionHigh pressure side manometers 63 Option Option Option STD Option (5) Option Option STD (9) STD STD STD STD Option STD OptionLow pressure side manometers 64 STD Option STD STD Option OptionAdditional capacity reduction steps 65Ambient outside temperature sensor and set-point reset

67 STD STD Option STD STD STD

Hour run meter 68 STD STD STD STD STD STD STD STD (11) STD STD STD STD STD STD STDGeneral fault contactor 69 STD STD STD STD STD STD STD STD STD STD STD STD STD STD STDContainer kit 71 Option Option Option Option Option Option Option Option Option OptionFork-lift kit 72 Option Option OptionWooden box packing 74

Rubber anti vibration mount 75 Option Option Option Option Option Option Option Option Option Option Option Option Option Option OptionSound proof system* 76 Option Option Option Option Option Option Option OptionSpring anti vibration mount 77 Option Option Option Option Option Option OptionOne centrifugal pump (low lift) 78 Option Option Option Option Option OptionOne centrifugal pump (high lift) 79 Option Option Option OptionTwo centrifugal pumps (low lift) 80 Option Option Option Option (6) Option (8) OptionTwo centrifugal pumps (high lift) 81 Option Option (6) Option (8)Witness test 82 CF CF CF CF CF CF CF CF CF CF OptionExternal tank without cabinet (500 l) 83 Option Option OptionExternal tank without cabinet (1000 l) 84 Option Option OptionExternal tank (500 l) with cabinet RAL7032 87 Option Option OptionExternal tank (1000 l) with cabinet RAL7032 88 Option Option OptionAcoustic test 89 CF CF CF CF CF CF CF CF CF CF

Set-point reset, demand limit and alarm from external device

90 Option STD STD STD Option STD STD STD STD STD STD STD STD Option STD

Double pressure relief valve with diverter 91 Option Option Option STD Option Option Option Option Option Option Option STD Option Option OptionLow ambient kit for 1 circuit 93Low ambient kit for 2 circuits 94

Compressor circuit breakers 95 Option Option Option Option Option Option Option OptionFans circuit breakers 96 STD STD STD STD STDMain switch interlock 97 STD (16) STD STD STD STD STD STD STDEmergency stop 98 Option STD STD STD STDFan speed regulation 99 STD (16) Option Option Option (7) OptionRefrigerant recovery tank 100 Option OptionEvaporator right water connection 101 Option Option OptionGround fault relay 102 Option Option Option CF OptionEvaporator 1pass 103 STD STD OptionEvaporator 2 passes 103a Option STDEvaporator 3 passes 103b STD OptionEvaporator Double Flange Kit 104 OptionLiquid receiver 105 Option Option OptionRapid restart 110 Option OptionHigh temperature kit 111 OptionTransport kit 112 Option Option Option Option Option Option Option Option Option Option Option Option Option Option Option OptionGlycol function .. OptionOptimized free cooling .. Option

359

GC_pre2_lowres.pdf 359 30/11/2011 12:32:11

Page 362: DAIKIN General Catalogue 2012

Accessories - chillers

Air cooled chillers

EWA/YQ009-011ACV3EWA/YQ009-013ACW1

EUWAC-FBZW1 EUWA/Y*-KBZW1 EWA/YQ~BA* EWA/YQ-DAYN EWAD~D- EWA(Y)D~BZ EWAD~C-

Panels

EKDSSPEKDSSP-S*** • •EKDDSP •EKPWPROEKPWPROMSerial Cards & Comm. Modules

EKAC10C • •EKACPG •EKAC200AEKAC200J •EKACBAC •EKACLON •EKACLONPEKACRS232EKACWEBEKACBACMSTPEKACBACCERT

EKCM200J • •EKCMLON • •EKCMBACMSTP • •EKCMBACIP • •LON Gateway

EKLONPG •Other Systems & Accessories

EKCLWSEKCON •EKCONUSB •EKMODEM •EKGSMOD •EKRP1HB •

EKRUPCJ •EKRUPCK

EKRUPCS • •EKPV2J •EKPWPROEXT

EKGWWEBEKGWMODEMEKBNPG •EKBMSBNAEKBMSMBAEKRUMCA •EKRUPCEKRUPG •EHMC*AV1010 •EHMC*AV1080 •EKRP1AHTA •DTA104A62 •EKRUAHTB •Gauges

EKGAU5/8KA • (5-8)EKGAU10/12KA • (10-12)EKGAU16KA • (16)EKGAU20/24KA • (20-24)BHGP26A1 •Soft starter

EKSS •Buffer tank

EKBT •Waterpipe kit

EKGN210 • (080-210)

EKGN260 • (EWAQ240-260DAYN& EWYQ230-250DAYN)

* To install EKRUMCA => EKAC10C needs to be installed on the unit. * EKAC10C allows direct connection to MODBUS BMS system * To install EKLONPG & EKBNPG => EKACPG needs to be installed on the unit.

360

GC_pre2_lowres.pdf 360 30/11/2011 12:32:12

Page 363: DAIKIN General Catalogue 2012

Water cooled chillers Centrifugals

EWAD~CZ EWAD-CF EWWP-KBW1N EWLP-KBW1N EWW(L)D~G- EWW(L)D~I- EWWD~H- EWWQ~B- EWW(L)D~J- EWWD~FZXS DWSC & DWDC

•• • • • • • • •• • • • • • • • •

• •• •

• •

• •• •• •

•• •• •• •• •

• • • • • • •• • • • • • •• • • • • • •• • • • • • •

• •• •• •• •

•• • • • • • •

• •• •• •

• •

••

• (014-045) • (012-030)

361

GC_pre2_lowres.pdf 361 30/11/2011 12:32:12

Page 364: DAIKIN General Catalogue 2012

Options - fan coil units

Type: FWM-DT/DF, FWL-DT/DF, FWV-DT/DF1 2 3 4 6 8 10 FWV FWL FWM

Description

Additional single row heat exchanger ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6 x x xElectric heater EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6 x x x2-pipe 3-way valve E2MV03A6 E2MV06A6 E2MV10A6 x x x4-pipe 3-way valve E4MV03A6 E4MV06A6 E4MV10A6 x x xFan stop thermostat YFSTA6 x x xAir intake & discharge grille EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6 - - xSupporting feet ESFV06A6 ESFV10A6 x - xSupporting feet + grille ESFVG2A6 ESFVG3A6 ESFVG6A6 ESFVG10A6 x - -

Fresh air intake EFA2A6 EFA3A6 EFA6A6 EFA10A6 x - -

Rear panel ERPV2A6 ERPV3A6 ERPV6A6 ERPV10A6 x x -

Control electromechanical ECFWMB6 x x xElectronic controller FWEC1A, FWEC2A, FWEC3A x x xMaster slave option EPIMSB6 x x xVertical drainpan EDPVA6 x x xHorizontal drainpan EDPHA6 - x xTemperature sensor kit FWTSKA x x xRelative humidity sensor kit FWHSKA x x xOn board FCU controller installation kit FWECKA x x -

1. Requires electronic controller

2. For FWD 12,16,18AT/AF only motor valve (piping not included)3. Water probe included

4. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall.

5. Requires electrical installation box with earth terminal KJB311A.

6. Requires electrical installation box KJB411A.

7. Requires installation box KRP1H98. (FWC)8. Requires installation box KRP1BA101 (FWF)

9. Requires electrical installation box with earth terminal KJB212A, if built in the wall.

10. Requires valve control PCB EKRP1C1111. I-touch:

• Not allowed to use the i-touch for an installation with both fan coils and VRV units.

• Can not be used in combination with fan coil units, that use MOD bus communication.

• No Airnet or telephone connection possible.

12. Only 1 of these 4 options can be installed on 1 indoor unit.13. Max. 1 KRP1H98 box can be mounted on the unit. Max. 2 PCB’s can be mounted in 1 KRP1H98 box. (FWC)

14. Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1PCB can be mounted in 1 KRP1BA101 box. (FWF)

Type: FWD-AT/AF4 6 8 10 12 16 18

Description

Electric heater: small(1)

EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6

Electric heater: big EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6

2-pipe 3-way valve(2)

ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6

4-pipe 3-way valve ED4MV04A6 ED4MV10A6 2xED2MV12A6 2 x ED2MV18A6

Vertical Drainpan EDDPV10A6 EDDPV18A6

Horizontal Drainpan EDDPH10A6 EDDPH18A6

Fan stop thermostat YFSTA6

Fresh air intake EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6

Electronic controller (3) FWEC1A, FWEC2A, FWEC3APower interface EPIB6

Master slave interface EPIMSA6

Temperature sensor kit FWTSKARelative humidity sensor kit FWHSKA

Type: FWB-BT2-4 5-7 8-10

DescriptionAdditional heat exchanger EAH04A6 EAH07A6 EAH10A6

3-way valve add. h/e E2MV307A6 E2MV310A6

3-way valve cooling h/e Factory mounted2-way valve add. h/e E2MV207A6 E2MV210A6

2-way valve cooling h/e Factory mountedElectric Heater Factory mountedFan stop thermostat YFSTA6

Power interface - - EPIB6

Master slave interface EPIMSB6

Electronic controller FWEC1A, FWEC2A, FWEC2ATemperature sensor kit FWTSKARelative humidity sensor kit FWHSKAOn board installation kit FWECKA

Type: FWB-JT/JF02 - 11

Description

2-pipe 3-way valve MCWCN

4-pipe 3-way valve MCWHN

362

GC_pre2_lowres.pdf 362 30/11/2011 12:32:12

Page 365: DAIKIN General Catalogue 2012

TYPEFWC-BT/BF FWF-BT/BF

Description

Decoration Panel (RAL 9010 - grey sealings) 4-way blow - BYFQ60BDecoration Panel - Standard (RAL 9010 - grey sealings) Round flow BYCQ140CW1

Decoration Panel - White (RAL 9010 - white sealings) Round flow BYCQ140CW1WSealing member of air discharge outlet KDBHQ55C140 KDBH44BA60Panel spacer - KDBQ44B60Long-life filter KAFP551K160 KAFQ441BA60Fresh air intake kit - Direct installation type - KDDQ44XA60Fresh air intake kit (20% fresh air) - Direct installation type KDDQ55C140-1 (*20) / KDDQ55C140-2 (*20) -

Remote controller - Wireless - H/P BRC7F532F (*18) BRC7E530 (*18)Remote controller - Wireless - C/O BRC7F533F (*18) BRC7E531 (*18)Remote controller - Wired BRC315D7 (*4)Central remote controller DCS302CA51 (*5)Electrical box with earth terminal (3 blocks) KJB311AUnified on/off controller DCS301BA51 (*9)Electrical box with earth terminal (2 blocks) KJB212ASchedule timer DST301BA51 (*6)(*9) DST301BA51 (*6)(*9)Wiring adapter for electrical appendices (1) KRP2A52 (*7) (*12) KRP2A52 (*9) (*12)Wiring adapter for electrical appendices (2) KRP4AA53 (*7) (*12) KRP4AA53 (*9) (*12)Installation box for adapter PCB KRP1H98 (*13) KRP1BA101 (*14)Remote sensor KRCS01-4 KRCS01-1

Intelligent touch controller DCS601C51C(*6) (*11) DCS601C51C (*6) (*11)Electrical installation box KJB411AOptional PCB for MOD-bus connection EKFCMBCB7 (*8) (*12) EKFCMBCB7 (*8) (*12)2-way valve - On/Off EKMV2C09B7 (*8) (*10) (*15) EKMV2C09B7 (*8) (*10) (*16)3-way valve - On/Off EKMV3C09B7 (*8) (*10) (*15) EKMV3C09B7 (*8) (*10) (*16)Valve control PCB EKRP1C11

Remote “On/Off” and “forced off” kit EKROROA (*17)

Description material FWT-BT FWF-CT FWC-AT FWC-AF

Standard wired remote controller with LCD MERCA x x x xSimplified wired remote controller (cooling only) SRC-COA x x x -

Simplified wired remote controller (heat pump) SRC-HPA x x x xWireless controller for cooling only WRC-COB x x x -

Wireless controller for heat pump WRC-HPB x x x xDecoration panel (600x600) including wireless controller H/P 2pipes DCP600TB - x - -

Decoration panel (900x900 / 2-pipe) including wireless controller H/P 2pipes DCP900TB - - x -

Decoration panel (900x900 / 4-pipe) including wireless controller H/P 4pipes DCP900FB - - - x

15. 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 +

1 x valve control PCB EKRP1C11

4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 +

1 x valve control PCB EKRP1C 11 (FWC)

16. 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 +

1 x valve control PCB EKRP1C11

4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 +

1 x valve control PCB EKRP1C11 (FWF)»

17. This option is needed to create T1 T2 wire.

18. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the

“auto airflow” setting.

Dry operation can be selected with this remote control, but this function is not available on the FWC model.

19. All options are supplied as kit.

20. Both parts of the fresh air intake are needed for each unit.

363

GC_pre2_lowres.pdf 363 30/11/2011 12:32:12

Page 366: DAIKIN General Catalogue 2012

AIR CONDITIONING1) nominal cooling capacities are based on:

Indoor temperature 27°CDB/19°CWBOutdoor temperature 35°CDBRefrigerant piping length 7.5m - 8/5m VRVLevel difference 0m2) nominal heating capacities are based on:

Indoor temperature 20°CDBOutdoor temperature 7°CDB/6°CWBRefrigerant piping length 7.5m - 8/5m VRVLevel difference 0m

APPLIED SYSTEMSAir cooled Cooling only Evaporator: 12°C/7°C Ambient: 35°CDB

Heat pump Evaporator: 12°C/7°C Ambient: 35°CCondenser: 40°C/45°C Ambient: 7°CDB/6°CWB

Water cooled Cooling only Evaporator: 12°C/7°CCondenser: 30°C/35°C

Heating only Evaporator: 12°C/7°CCondenser: 40°C/45°C

Condenserless chiller Evaporator: 12°C/7°CCondensing temperature: 45°C / liquid temperature: 40°C

Fan coil units Cooling Room temperature: 27°C/19°CEntering water temperature: 7°C/12°C

Heating Room temperature: 20°CWater inlet temperature: 50°C (2-pipe)/70°C (4-pipe)

POWER SUPPLY

T1 = 3~, 220V, 50Hz

V1 = 1~, 220-240V, 50Hz

VE = 1~, 220-240V/220V, 50Hz/60Hz*

V3 = 1~, 230V, 50Hz

VM = 1~, 220~240V/220~230V, 50Hz/60Hz

W1 = 3N~, 400V, 50Hz

Y1 = 3~, 400V, 50Hz

MEASURING CONDITIONS

* For VE power supply only 1~, 220-240V, 50Hz data is displayed in this catalogue.

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates.For more detailed information please consult our technical databooks.

364

GC_pre2_lowres.pdf 364 30/11/2011 12:32:12