5-AG_SS02_E2 ZXMSG 5200 (V3.1) System Structure(Ppt) 73p

Post on 10-Nov-2014

78 views 27 download

description

description

Transcript of 5-AG_SS02_E2 ZXMSG 5200 (V3.1) System Structure(Ppt) 73p

ZXMSG 5200(V3.1) SystemStructure

ZTE University

1

Course Object

nnn Understand interfaces and functions of IPMSAN

nnn Master network and service of IP MSAN

nnn Master system structure of IP MSAN

nnn Master boards of IP MSAN

2

System Overview

nnn Network Evolutionnnn Functionsnnn Interfacesnnn Technical specifications

3

Network Evolution--MSAN

4

Network Evolution--MSAG

5

Functionsl Support H.248, MGCP or SIP.

l Support real time transport protocol RTP/RTCP.

l Support code and encode arithmetic G.711,G.729, G.723.1.

l Support broadband interfaces likeADSL/ADSL2+, VDSL2, SHDSL, GPON andEthernet.

l Support PSTN service, ISDN service, FAX ser-vice, V5 interface, xDSL service, CES serviceand GPON service.

6

InterfacesØØØ Subscriber-side Interface

l POTS analog subscriber interface

l ISDN 2B+D/30B+D subscriber interface

l xDSL subscriber interface

l FE/GE Ethernet interface

l GPON interface

l E1 interface

7

InterfacesØØØ Network-side Interface

l FE/GE/10GE Ethernet/Optical interface

l E1 interface

l ATM interface

l Maintenance serial port

l Maintenance network port

l Environment&powermonitor port

8

Technical Specificationsl Capacity:

à 1856 analog subscribers

à 1856 ADSL2+ subscribers

à 928 VDSL2 subscribers

à Minimum 240 VOIP ports

l BHCA: 20 K

l Codec:

à G.711

à G.729a

à G.723.1

9

Network and Service

nnn Network Typennn Hair-pinnnn Self-switch

10

Network Type 1--IP MSAN in NGN

11

Network Type 2--MSAN Upgrade to MSAG

12

Hair-pin

13

Self-switch

14

System Structure

nnn Cabinetsnnn Shelvesnnn Working Principlennn Control and Switch Cardsnnn Packet Processing and Resource Cardsnnn Uplink cardsnnn Ethernet cardsnnn Narrowband Subscriber cardsnnn Broadband Subscriber Cardsnnn Power Cardnnn Other Cards

15

CabinetsCabinet Dimension

(mm)(H×W×D)

Weight(kg)

PowerConsump-tion (W)

Type User Num-ber(nar-rowband)

User Num-ber(broad-band)

19D06H20 2000×600×600

250 1750 indoor 1856 1856

OUT60 1600×1500×780

620 1050 outdoor 1088 1152

16

IP MSAN Shelf Type

17

IP MSAN Shelf Type

18

19D06H20 Shelf Structure

19

OUT60 Shelf Structure

20

Working Principle

21

Working Principlel Narrowband service

After entering the TDM switch of the GIS, suchnarrowband service as POTS transfers voice intoIP packet by the voice compression function of theMPRB. The service switches to the CNIC throughan Ethernet switching chip for Network AddressTranslation (NAT), and then enters the IP networkfrom the uplink interface by Ethernet switching.

l Broadband service

Direct forward to Ethernet switching and uplink tometro Ethernet network

22

Control and Switching CardsCard Full Name Port & DescriptionGIS Giga ethernet integrated

control and switching card4 K VLANs,two GE plustwo FE uplink ports,GE starcascading between shelves

GISX Giga ethernet integratedcontrol and switchingcard typeX

10 GE uplink ports,1:1 vlan

23

Packet Processing and Resource CardsCard Full Name FunctionMPRB Packet processing and

resource card type BVOIP and resource card forvoice call,240 channels

24

Uplink CardsCard Full Name Function Port & DescriptionSUPI Slave shelf uplink

interface cardUplink, cascade One GE or one FE

uplink port (only validin the slave shelf)

EUX Ethernet uplinkinterface card

Uplink, cascade Two uplink FEelectrical ports, fourFE cascading portsfor control unit andbroadband services

GEI 1000 M ethernetcascade interfacecard

Uplink, cascade Two uplink FEelectrical ports, twouplink GE optical ports

25

Ethernet CardsCard Full Name Function Port & DescriptionGETC 1000 M ethernet

interface cardEthernet layer 2switching function

One or two GE opticalinterface

GETI 100 M ethernetinterface card

Ethernet layer 2switching function

Four FE ethernetinterface

GATI ATM optical interfacecard

Conversion of signalsbetween ATM andethernet

One ATM opticalinterface

26

Narrowband Subscriber CardsCard Full Name Function Port & DescriptionALC Analog line card POTS access 32 analogsubscriber

portsRALC Reverse analog line

cardPOTS access andreversed polarity

32 analogsubscriberports

FLC Far-end analog linecard

POTS access,reversed polarity, 12KC/16 KC meteringpulse and longdistance functions

16 analog subscriberports

DLCE Digital subscriber card Basic rate interface forISDN. Transceiving of2B+D data and formatconversion

2B+D channel andU interface functionof the ISDN physicallayer

27

Broadband Service CardsCard Full Name Function Port & DescriptionGADL 16-port ADSL

subscriber cardADSL/ADSL2/ADSL2+ subscriber access

16 ADSL/ADSL2/AD-SL2+ ports

GAGL 32-port ADSLsubscriber card

ADSL/ADSL2/ADSL2+ subscriber access

32 ADSL/ADSL2/AD-SL2+ ports

GVDL 16-port VDSL2subscriber card

Conversion fromVDSL to ethernet port;receiving eight VDSLsignals; VLAN andmulticast functions

16 VDSL2 ports

GSDL 16-port SHDSLsubscriber card

SHDSL subscriberaccess

16 SHDSL ports

GSDLB 16-port SHDSL.bissubscriber card

SHDSL.bis subscriberaccess, high-rate,high-centralizationand low powerconsumption

16 SHDSL.bis ports

28

Power CardCard Full Name Function Port & DescriptionPOWER K Power Card Secondary power and

ringing currentPower connector onthe backplane

29

OthersCard Full Name Function Port & DescriptionODTI Octal digital interface

cardConversion of signalsbetween two 8 MbpsHW and eight E1s

8 E1 ports

CEE 16–port E1 interfacecircuit emulation card

Realizing TDMoIPthrough circuitemulation mode

16 E1/T1 ports

GPOI 4–port GPONsubscriber card

Conversion betweenGEM frame andethernet frame

4 GPON ports

GILCA Giga Integrated LineCard

Functions of ALC cardand GADL card

16 integratedADSL/POTS ports

GELC Giga High-densityIntegrated Line Card

Functions of ALC cardand GADL card

32 integratedADSL/POTS ports

EPC Environment powercontrol card

Collections ofenvironment alarmand power data;reporting localalarm and real-timemonitoring data at thesame time

-

30

Board Principle

nnn Board Functionnnn Board Panelnnn Board Indicatorsnnn Board Interfaces

31

GIS/GISXl Performs management functions and circuit sta-

tus scanning of downlink subscriber line cards.

l System control and H.248 managements.

l One card has 4 E1s interfaces.

l Performs TDM switching (2K*2K),Ethernetswitching and network functions.

l Supports active/standby working modes.

l Provides two RS-232 ports. One is connected toenvironment power monitoring module; other isconnected to NMS computer.

l GISX provides two 10 G optical ports for uplink.

32

GIS/GISX Panel

33

GIS/GISX Panel

34

GIS/GISX PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.M/S Green ON Card is active.NACT Green Flashing Narrowband service is normal.BACT Green Flashing Broadband service is normal.DT Green ON 2 Mbps trunk is running normally.GE1 Green Flashing Uplink port 1 is running normally.GE2 Green Flashing Uplink port 2 is running normally.

35

MPRBl TONE

l DTMF

l CID

l Conference call

l 240 channels for VoIP processing resources

36

MPRB Panel

37

MPRB PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.DSP1 Green Flashing DSP1 is working normally.DSP2 Green Flashing DSP2 is working normally.

38

ALCl Provides 32 analog subscriber lines

l Subscriber supply voltage: -48 V

l Subscriber supply current: 0.02 A

l Ringing current voltage: 75

l Card power consumption: 40 W

39

ALC Panel

40

ALC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.HOOK Green ON One or more subscribers hook-off.

41

DLCEl Provides 2B+D interface and performs U inter-

face function of ISDN physical layer.

l Provides self loop detection and over voltageprotection.

l Performs link layer processing for D channel sep-aration based on I440/I441 protocol.

l Sends the processed signaling to GIS, and pro-vides communication with ISDN network layer.

l Allocates time slots for two B channels based onGIS instruction.

l Provides test ports for user test cards.

42

DLCEl Provides remote power supply via U interface,

when local system fails to provide power supplyto Network Terminal1 (NT1).

43

DLCE Panel

44

DLCE PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.U1~U8 Green ON The corresponding U interface is activated.

45

GADLl GADL card is connected to other Ethernet

switching devices through Ethernet interface.

l Communicates with main control card throughHDB protocol to implement related NM functions.

l Provides 16-channel ADSL interface to imple-ment ATM cell access.

l Follows G.dmt and G.Lite standards.

l Contains a built-in 16-channel splitter.

46

GADL Panel

47

GADL PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.ACT Green ON Link is UP.

48

GAGLl GAGL card is connected to other Ethernet

switching devices through Ethernet interface.

l Communicates with control and switching cardvia HDLC to implement NM functions.

l Provides 32-channel ADSL interface to imple-ment ATM cell access.

l Follows G.dmt and G.Lite standards.

l Works with PAUN (32-channel ADSL splittercard).

49

GAGL Panel

50

GAGL PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.ACT Green ON Link is up.

51

PAUNPANU card is 32-channel splitter card with 3 U height.It is plugged-in the slot under GAGL card.

52

PAUN

53

EUX Panel

54

EUX Panell X5, X6 are used for Ethernet uplink.

l X4 is used for cascading.

55

IEBA Panel

56

IEBA PanelInterface Description1 68-core socket, E1 cable interface2 RJ-9 interface for debugging cable3 RJ-9 interface for monitoring cable connected

to EPC or EPM card

57

IEBC Panel

58

IEBC PanelInterface Description1 Uplink interface (GE optical interface or FE

electrical interface)2 Uplink interface (GE optical interface or FE

electrical interface)3 DB-50 cascade socket, which supports 3

slave frames

59

POWER Kl Supplies secondary power and ringing current

for subscriber layer.

l Supplies four types of voltages: +5 V, -5 V, -48 Vand 75 V AC ringing current.

60

POWER K Panel

61

POWER K PanelLED Color Status DescriptionALM Red ON Card is faulty.-48V Green ON -48 V supply is normal.Ring Green Flashing Card is running normally.+5V Green ON +5 V supply is normal.+5VJ Green ON +5VJ supply is normal.-5V Green ON -5 V supply is normal.

62

PEB

63

PEBInterface Description1 Three-core power socket2 POWER K control interface; This interface can

be connected to EPC or EPM card.3 POWER K detection interface; It is connected

to EPC or EPM card.4 Interconnection test interface5 Interconnection test interface

64

EPCl EPC card provides environment monitoring pa-

rameters such as temperature, humidity, smoke,dust, fog and moist.

l EPC is mainly used to collect environment andpower data from external interface.

l EPC card also detects equipment related to out-put control, and reports the local alarm data andreal-time data simultaneously. This card is usedin standard shelf.

65

EPC Panel

66

EPC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.OTH Red ON Card is faulty.SMK Red ON Smoke is detected.HUM Red ON Humidity exceeds the threshold limits.FLOW Red ON Water level is above the limit.DOOR Red ON Door is open.TEMP Red ON Temperature exceeds the threshold limits.POWR Red ON Power supply is abnormal.

67

EPEB PanelEPEB is the extension card for EPC card. It isplugged-in the slot under EPC card. The front panelhas the interface to connect the monitoring cable.

68

EPEB Panel

69

TSLCl Loop line testing

l Internal line test

l Subscriber telephone function test

70

TSLC Panel

71

TSLC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.Test Green Flashing Test is ON.

72

73