8/18/2019 FM200i HW Install
1/17
FlexiPacket FirstMile 200i
R2.0EP2
IDU HW Install
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
Nokia Siemens Networks is continually str iving to reduce the adverse environmental effects of
its products and services. We would like to encourage you as our customers and users to join
us in working towards a cleaner, safer environment. Please recycle product packaging and
follow the recommendations for power use and proper disposal of our products and their
components.
If you should have questions regarding our Environmental Policy or any of the environmental
services we offer, please contact us at Nokia Siemens Networks for any additional information.
8/18/2019 FM200i HW Install
2/17
2 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW Install
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-
TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT
LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2013. All rights reserved.
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the “Legal, Safety
and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,
Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-
satzes.
8/18/2019 FM200i HW Install
3/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
3
IDU HW Install
Table of ContentsThis document has 17 pages.
1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Structure of this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 History of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 Symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 Waste electrical and electronic equipment (WEEE) . . . . . . . . . . . . . . . . 9
1.6 RoHS compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.7 CE compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.8 MEF compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Mechanical Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1.1 Shape and Dimension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1.2 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 Install FPFM200i into Flexi Multiradio 10 BTS. . . . . . . . . . . . . . . . . . . . 12
4 Connect FPFM200i to Flexi Multiradio 10 BTS cabling . . . . . . . . . . . . . 17
8/18/2019 FM200i HW Install
4/17
4 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW Install
List of FiguresFigure 1 WEEE label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3 MEF certified compliant logo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 4 FPFM200i front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 5 Removing dummy unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 6 Removing rubber plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 7 Inserting connection card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 8 Installing transmission sub-module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 9 Fixing transmission sub-module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 10 Connect FPFM200i cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8/18/2019 FM200i HW Install
5/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
5
IDU HW Install
List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 2 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 3 List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 4 FPFM200i dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8/18/2019 FM200i HW Install
6/17
6 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW Install
8/18/2019 FM200i HW Install
7/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
7
IDU HW Install Preface
1 PrefaceThis document provides the information on how to install FlexiPacket FirstMile 200i
(later referred as FPFM200i).
1.1 Intended audience
This document is intended for the installer who is responsible for installing FPFM200i.
1.2 Structure of this document
The document is divided into the following main chapters:
1.3 History of changes
1.4 Symbols and conventions
The following symbols and mark-up conventions are used in this document:
Chapter Title Subject
Chapter 1 Preface Provides an introduction to thedocument
Chapter 2 Overview Provides an overview of FPFM200i
Chapter 3 Install FPFM200i into Flexi
Multiradio 10 BTS
Provides the information of how to install
FPFM200i into Flexi Multiradio 10 BTS
Chapter 4 Connect FPFM200i to Flexi
Multiradio 10 BTS cabling
Provides the information of cabling
when connect FPFM200i into Flexi Mul-
tiradio 10 BTS
Table 1 Structure of this document
Issue Issue date Remarks
1.0 April 2013 1st version
Table 2 History of changes
8/18/2019 FM200i HW Install
8/17
8 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW InstallPreface
Representation Meaning
fDANGER!
fWARNING!
fCAUTION!
A safety message indicates a dangerous situation where
personal injury is possible.
The keywords denote hazard levels with the following meaning:
DANGER! - Indicates a hazardous situation which, if not
avoided, will result in death or serious (irreversible) personal
injury.
WARNING! - Indicates a hazardous situation which, if not
avoided, could result in death or serious (irreversible) personal
injury.
CAUTION! - Indicates a hazardous situation which, if not
avoided, may result in minor or moderate (reversible) personal
injury.
wNOTICE: A property damage message indicates a hazard that may resultin equipment damage, data loss, traffic interruption, and so on.
g A note provides important information related to the topic, forexample, not obvious exceptions to a rule or side effects.
t A tip provides additional information related to the topic which isnot essential in the context, but given for convenience.
Bold • All names of graphical user interface (GUI) objects, such as
windows, field names, buttons, and so on.
Example: Select the Full Screen check box and press OK.
• Terms and abbreviations which are linked to an entry in theglossary and list of abbreviations respectively
• Important key words
Italic • Files, folders, and file system paths.
Example: /usr/etc/sbin/ftpd.exe
• Emphasized words
typewriter • Input to be typed in a command line or a GUI field.
Examples:
ping -t 192.168.0.1
Enter World in the Domain field.
• Output from a command, error messages, content of a statusline, and so on
• File content, such as program sources, scripts, logs, and
settings
Placeholders, for example as part of a file name or field value.
Examples:
.png or :
Table 3 List of symbols and conventions
8/18/2019 FM200i HW Install
9/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
9
IDU HW Install Preface
Screenshots of the graphical user interface are examples only to illustrate principles.
This especially applies to a software version number visible in a screenshot.
1.5 Waste electrical and electronic equipment (WEEE)
All waste electrical and electronic products must be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the government
or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.
Figure 1 WEEE label
The correct disposal and separate collection of waste equipment will help prevent poten-
tial negative consequences for the environment and human health. It is a precondition
for reuse and recycling of used electrical and electronic equipment.
For more detailed information about disposal of such equipment, please contact Nokia
Siemens Networks.
The above statements are fully valid only for equipment installed in the countries of the
European Union and is covered by the directive 2002/96/EC. Countries outside the
[square brackets] A key to be pressed on a PC keyboard, for example [F11].
Keys to be pressed simultaneously are concatenated with a “+”
sign, for example [CTRL]+[ALT]+[DEL].
Keys to be pressed one after another are concatenated with
spaces, for example [ESC] [SPACE] [M].
> The greater than symbol “>” is used to concatenate a series of
GUI items in order to depict a GUI path. This is an abridged pre-
sentation of a procedure to be carried out in order to perform an
action or display a window or dialog box.
Examples:
A simple menu path: File > Save as ...
A more complex GUI path:SURPASS TransNet window > Tools menu >
3R-Matrix Report command > 3R-Matrix Report dialog box
x
(in card names)
For convenience, card names are sometimes listed with a lower
case x variable, in order to concisely represent multiple cards.
Example:
I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)
Representation Meaning
Table 3 List of symbols and conventions (Cont.)
8/18/2019 FM200i HW Install
10/17
10 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW InstallPreface
European Union may have other regulations regarding the disposal of electrical and
electronic equipment.
1.6 RoHS complianceFPFM200i complies with the European Union RoHS Directive 2002/95/EC on the
restriction of use of certain hazardous substances in electrical and electronic equipment.
The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-
brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical
and electronic equipment put on the market after 1 July 2006.
Materials usage information on Nokia Siemens Networks Electronic Information
Products imported or sold in the People’s Republic of China
FPFM200i complies with the Chinese standard SJ/T 11364-2006 on the restriction of the
use of certain hazardous substances in electrical and electronic equipment. The
standard applies to the use of lead, mercury, cadmium, hexavalent chromium, polybro-minated biphenyls (PBB), and polybrominated divinely ethers (PBDE) in electrical and
electronic equipment put on the market after 1 March 2007.
1.7 CE compliance
FPFM200i is in compliance with the essential requirements and other relevant provi-
sions of Directive: 2006/95/EC, 2004/108/EC, and 1999/5/EC.
Figure 2 CE marking
1.8 MEF compliance
FPFM200i operating at the NNI delivers EPL, EVPL and E-LAN service complies with
the Metro Ethernet Forum MEF14 technical specification. FPFM200i operating at the
UNI delivers EPL, EVPL and E-LAN service complies with the Metro Ethernet Forum
MEF9 technical specification.
Figure 3 MEF certified compliant logo
The product is marked with the CE marking
8/18/2019 FM200i HW Install
11/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
11
IDU HW Install Overview
2 Overview
2.1 Mechanical Structure
2.1.1 Shape and Dimension
The FlexiPacket FirstMile 200i (Later referred as FPFM200i in short) indoor unit (IDU)
has been made into a card that can be inserted into and works with the Flexi Multiradio
10 BTS, which is a standard sub-rack that is compatible with standard 19-inch rack and
ETSI N3 rack.
Table 4 shows the dimensions of FPFM200i:
2.1.2 Front Panel
The following is the front panel of FPFM200i.
Figure 4 FPFM200i front panel
2.2 System Types
For FPFM200i release 2.0EP2, all system types that can be configured are as follows:
1. N x (1+0), N = 1...4
2. N x (1+1), N = 1…2
3. N x (2+0), N = 1…2
g The system types can be mixed configured on one equipment.
Height 37.5 mm
Width 245 mm
Depth 321.9 mm
Table 4 FPFM200i dimensions
8/18/2019 FM200i HW Install
12/17
12 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW InstallInstall FPFM200i into Flexi Multiradio 10 BTS
3 Install FPFM200i into Flexi Multiradio 10 BTSBefore you start
The System Module has to be powered off before installing or replacing the transmissionsub-module.If cable entries are installed, remove them.
Steps
Remove the FPFM200i dummy unit as follows:
a Undo the screws holding the FSMx core in place.
b Pull out the core.
c Remove the four screws holding the FPFM200i dummy unit in place.
g Leave the other dummy units in place if you are not installing any other optional sub-modules.
8/18/2019 FM200i HW Install
13/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
13
IDU HW Install Install FPFM200i into Flexi Multiradio 10 BTS
Figure 5 Removing dummy unit
2 Remove the rubber plugs on the core and the transmission sub-module.
8/18/2019 FM200i HW Install
14/17
14 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW InstallInstall FPFM200i into Flexi Multiradio 10 BTS
Figure 6 Removing rubber plugs
3 Insert the connection card into the slot on the FSMx core.
g The transmission sub-module connection card looks identical with the connectioncard for the FPFD. Make sure you are inserting the correct card.
Figure 7 Inserting connection card
4 Align the transmission sub-module with the guide pin on the FSMx core and push
the sub-module in place.
8/18/2019 FM200i HW Install
15/17
A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
15
IDU HW Install Install FPFM200i into Flexi Multiradio 10 BTS
Figure 8 Installing transmission sub-module
5 Fix the transmission sub-module with 4 x M5x25 screws (included in the accessory
bag) and tighten to 4.0 Nm.
g Do not reuse dummy unit screws.
8/18/2019 FM200i HW Install
16/17
16 A25000-A1700-A031-01-76P1
Issue: 1 Issue date: April 2013
IDU HW InstallInstall FPFM200i into Flexi Multiradio 10 BTS
Figure 9 Fixing transmission sub-module
6 Re-insert the module core and fix the screws.
8/18/2019 FM200i HW Install
17/17
A25000-A1700-A031-01-76P1 17
IDU HW Install Connect FPFM200i to Flexi Multiradio 10 BTS cabling
4 Connect FPFM200i to Flexi Multiradio 10 BTS
cabling
g Incorrect cables and seals may not provide secured weather protection. In outdoorinstallations, including the outdoor cabinet, use only tested IP65 class outdoor cables
with seals provided by Nokia Siemens Networks. This is also recommended for indoor
installations.
Summary
Figure 10 Connect FPFM200i cabling
Steps
Remove IP seals from the relevant transmission sub-module ports.Store the seals for later use.
2 Route a transmission cable through the cable entry.
3 Pull back the connector seal covering the transmission cable connector.
4 Connect the cable to the transmission sub-module.
5 Push the cable connector seal firmly in place.
6 Coil up the excess cable and fix it on the module casing with cable ties.
7 Repeat steps 2-6 for all the transmission cables required for your configuration.
8
Make sure that all the connector seals are properly installed.