ROOMS - Engineering...
Transcript of ROOMS - Engineering...
GF-
LVA
U-0
3
GF-EVAU-02
GF-LV
AU
-04
GF-LVAU-05
GF-EV
AU
-03
MZF2-H
W-14
1.5 TR
MZF2-HW-131.5 TR
MZF2-HW-151.5 TR
MZF2-H
W-17
1.5 TR
MZF2-HW-161.5 TR
MZF2-HW-181.5 TR
DP
DP
DP
DP DP
MZF
1-A
CC
U-0
81.
5 TR
MZF
1-A
CC
U-0
71.
5 TR
MZF
1-A
CC
U-0
91.
5 TR
MZF1-ACCU-101.5 TR
MZF1-ACCU-111.5 TR
MZF1-ACCU-121.5 TR
300MM DEPTH CONCRETE PEDESTAL
300MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
300MM DEPTH CONCRETE PEDESTAL
300M
M D
EPTH
C
ON
CR
ETE
PED
ESTA
L
150MM DEPTH CONCRETE PEDESTAL
Duct @300mm fromfloor level
Duct @300mm fromfloor level
Ref. piping to above
DP
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
ROOMS
DRAIN PIPE
REF. PIPE
TYPICAL SIDE VIEW FOR HI-WALL UNIT
TYPICAL FRONT ELEVATION FORHIGHWALL MOUNTED INDOOR UNIT
SLAB
REF. PIPES &
WALL CONCEALED
(LL & SL)
CONNECTED IN
A FLOOR TRAP
ROOMS
SLAB
DRAIN PIPE
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR202&203 SHOP @ SECOND MEZZANINE FLOOR
GF-LVAU-04
GF-EVAU-02
GF-LVAU-05
GF-EVAU-03
GF-LVAU-03
GF-LVAU-06
DP
GF-HW-011.5 TR
GF-HW-021.5 TR
GF-ACCU-021.5 TR
GF-ACCU-011.5 TR
DP
150MM DEPTH CONCRETE PEDESTAL
Drains are droppingvertically and runningfloor concealed
@ 2.4 M FFL
@ 2.4 M FFLBOD-3.0M
GF-LVAU-04
GF-EVAU-02
GF-LVAU-05
GF-EVAU-03
DP
GF-HW-011.5 TR
GF-HW-021.5 TR
GF-ACCU-021.5 TR
GF-ACCU-011.5 TR
DP
150MM DEPTH CONCRETE PEDESTAL
Drains are droppingvertically and runningfloor concealed
@ 2.4 M FFL
@ 2.4 M FFLBOD-3.0M
GF-LVAU-03
GF-LVAU-06
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
THREADED ROD
DUCT
M.S SPIRAL DUCT
HOLDING CLAMP
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR202 SHOP @ GROUND FLOOR
MZF1-H
W-08
1.5 TR
MZF1-HW-071.5 TR
MZF1-HW-091.5 TR
DP DP
1.5 TR
MZF1-HW-101.5 TR
MZF1-HW-121.5 TR
DP DP
MZF1-H
W-11
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
ROOMS
DRAIN PIPE
REF. PIPE
TYPICAL SIDE VIEW FOR HI-WALL UNIT
TYPICAL FRONT ELEVATION FORHIGHWALL MOUNTED INDOOR UNIT
SLAB
REF. PIPES &
WALL CONCEALED
(LL & SL)
CONNECTED IN
A FLOOR TRAP
ROOMS
SLAB
DRAIN PIPE
1.5 TR
MZF1-HW-101.5 TR
MZF1-HW-121.5 TR
DP DP
MZF1-H
W-11
MZF1-H
W-08
1.5 TR
MZF1-HW-071.5 TR
MZF1-HW-091.5 TR
DP DP
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR202 SHOP @ FIRST MEZZANINE FLOOR
GF-LVAU-06
GF-LVAU-07
GF-LVAU-08
GF-LVAU-07
GF-LVAU-09
DP
GF-HW-031.5 TR
GF-A
CC
U-03
1.5 TRG
F-AC
CU
-042.0 TR
PLENU
M:
1250x700x550 mm
GF-D
SU-08:
1600x700x 500 mm
DP
PLENUM:1250x700x400 mm
GF-DSU-07:1600x700x500 mm
SD / RD: # 4SIZE: 525 x 525 mmCAP: 750 CFM EACH
850x
350
T75
0x25
0
SD / RD: # 6SIZE: 525 x 525 mm
CAP: 560 CFM EACH
GF-HW-062.0 TR
GF-A
CC
U-06
2.0TR
DP DP
GF-A
CC
U-05
2.0TR
PLENUM:1100x500x500 mm
FACE GRILL:1000x400 mm
GF-DSU-03:1220x700x 500 mm
GF-O
DU
-04
CP
GF-O
DU
-08
DP
CPPLEN
UM
:1100x500x500 m
m
FAC
E GR
ILL:1000x400 m
m
GF-D
SU-04:
1220x700x 500 mm
PLENUM:1100x500x500 mm
FACE GRILL:1000x400 mm
GF-DSU-05:1220x700x 500 mm
GF-O
DU
-05
DPCP
GF-HW-052.0 TR
750x350
450x
350
GF-O
DU
-07:
DPCP
GF-O
DU
-06:
CP
GF-O
DU
-03G
F-OD
U-02
DPCP
PLENUM:1100x500x500 mm
FACE GRILL:1000x400 mm
GF-DSU-02:1220x700x 500 mm
CP
PLENU
M:
1250x700x400 mm
GF-D
SU-06:
1600x700x500 mm
DP
700x250
700x250
SD / RD: # 6SIZE: 525 x 525 mm
CAP: 560 CFM EACH
300MM DEPTH CONCRETE PEDESTAL
300 MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
300 MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
300MM DEPTH CONCRETE PEDESTAL
Ref. piping at ceiling level
Ref. piping at low level150 OR 300 mm FFL
Ref. piping at low level150 OR 300 mm FFL
Ref. piping at low level150 OR 300 mm FFL
Ref. piping at ceiling level
BOD-3.7 m
Ref. piping at low level150 OR 300 mm FFL
Ref. piping at ceiling level
Ref. piping at ceiling level
Ref. piping at low level150 OR 300 mm FFL
BOD-3.65M
250x
350
ROOM NO. 043 THE AC UNITS ARE CHANGE i.e DSU to HI-WALL due to the interference of crane
Refer Option - I
STATED DUCTDIMENSION
SOFFIT SLAB LEVEL;
DIM
ENSI
ON
STA
TED
DUC
T
25MM/50MM GI ANGLE BRACKETLOCK NUTS & WASHERS
MINIMUM 10mm DIA DROP ROD
DUCT WALL
EXPANDING BOLTS
SLAB
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
THREADED ROD
DUCT
M.S SPIRAL DUCT
HOLDING CLAMP
DP
CP
CPCP
150MM DEPTH CONCRETE PEDESTAL
GF-HW-071.5 TR
GF-HW-081.5 TR
GF-HW-121.5 TR
GF-HW-111.5 TR
GF-H
W-09
1.5 TRG
F-HW
-101.5 TR
GF-A
CC
U-08
1.5 TRG
F-AC
CU
-071.5 TR
GF-A
CC
U-09
1.5 TRG
F-AC
CU
-101.5 TR
GF-A
CC
U-11
1.5 TRG
F-AC
CU
-121.5 TR
DP
DPRef. piping at low level150 OR 300 mm FFL
DP
OPTION - I
Ref. piping at low level150 OR 300 mm FFL
Ref. piping at low level150 OR 300 mm FFL
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR202 SHOP @ GROUND FLOOR
PLEN
UM
:12
50x7
00x4
00 m
m
MZF
1-D
SU-0
116
00x7
00x5
00 m
m
750x350T450x350
SD / RD: # 4SIZE: 525 x 525 mm
CAP: 750 CFM EACH
PLENUM:2050x850x600 mm
MZF1-DSU-021220x700x 500 mm
MZF1-DSU-031220x700x 500 mm
1050
x350
600x
350
SD / RD: # 6SIZE: 525 x 525 mmEACH:735 CFM
DP
DP
CP
CP
DP
CP
PROPELLER FAN- #3EACH 500 CFM
PROPELLER FAN- #1EACH 560 CFM
PROPELLER FAN- #2EACH 500 CFM
PROPELLER FAN- #1EACH 500 CFM
PROPELLER FAN- #1EACH 500 CFM
PROPELLER FAN- #1EACH 500 CFM
PROPELLER FAN- #8EACH 560 CFM
PROPELLER FAN- #2EACH 500 CFM
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BOPF-3.0 M
BO
D-3
.2M
Ref. piping at ceiling level
BOD-3.275M
THREADED ROD
DUCT
M.S SPIRAL DUCT
HOLDING CLAMP
STATED DUCTDIMENSION
SOFFIT SLAB LEVEL;
DIM
ENSI
ON
STA
TED
DUC
T
25MM/50MM GI ANGLE BRACKETLOCK NUTS & WASHERS
MINIMUM 10mm DIA DROP ROD
DUCT WALL
EXPANDING BOLTS
SLAB
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
Adjustable Diffuser
Blade
Brush Strip Seal
Adjustable Vanes
I
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR203 SHOP @ FIRST MEZZANINE FLOOR
GF-LVAU-01
GF-EVAU-01
GF-LVAU-02
PLEN
UM
:12
50x7
00x4
00 m
m
GF-
DSU
-01:
1600
x700
x500
mm 750x350 T 450x350
SD / RD: # 4SIZE: 525 x 525 mm
CAP: 750 CFM EACH
GF-
OD
U-0
1:14
00x6
00(D
)x90
0(H
) mm
CP
DUCT IS RUNNING AT 6.85M LVL
CONCRETEPEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
Plenum size: 1600(L)X1950(W)X2000(H)
DUCT IS RUNNING AT 3.85M LVL
Plenum size:850(L)X850(W)X750(H)
cutouts in wall/slab
DP
BOD-3.38M
STATED DUCTDIMENSION
SOFFIT SLAB LEVEL;D
IMEN
SIO
N
STA
TED
DUC
T
25MM/50MM GI ANGLE BRACKETLOCK NUTS & WASHERS
MINIMUM 10mm DIA DROP ROD
DUCT WALL
EXPANDING BOLTS
SLAB
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
I
THREADED ROD
DUCT
M.S SPIRAL DUCT
HOLDING CLAMP
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR209 SHOP @ GROUND FLOOR
1000x600
GF-LVAU-02
MZF1-ACCU-011.5 TR
MZF
1-A
CC
U-0
41.
5 TR
MZF1-ACCU-021.5 TR
MZF1-ACCU-031.5 TR
MZF
1-A
CC
U-0
51.
5 TR
MZF
1-A
CC
U-0
61.
5 TR
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
Ref. piping at low level150 OR 300 mm FFL
TYP.
Ref. piping at low level150 OR 300 mm FFL
TYP.
Plenum size:1000(L)X1150(W)X1150(H)
Typical detail & flashing by contractor
Plenum size:1500(L)X3000(W)X1500(H)
Plenum size:1500(L)X3000(W)X1500(H)
AHU DRAIN POINT
AHU DRAIN POINT
AHU DRAIN POINT Plenum size:1500(L)X3000(W)X1500(H)
Plenum size:1500(L)X3000(W)X1500(H)
AHU DRAIN POINT
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
23800
18381 8605
WELDED OR BOLTED
TO PURLIN
THREADED ROD
HOLDING CLAMP
ISMC SUPPORT MEMBER
BETWEEN PURLINS BY OTHER.
WITH LOCKNUT
DUCT
LOAD DESIGNED
BY MAX 75 KG/Sqmt.
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FOR209 SHOP @ SECOND MEZZANINE FLOOR
ROOM NO. 043 THE AC UNITS ARE CHANGE i.e DSU to HI-WALL due to the interference of crane
Refer Option - I
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER EQUIPMENT SCHEDULELAYOUT
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER EQUIPMENT SCHEDULELAYOUT
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER EQUIPMENT SCHEDULELAYOUT
MZF1-LVAU-10
MZF1-LVAU-11
GF-LVAU-06
MZF1-ODU-01
MZF1-ODU-03
MZF1-ODU-02
MZF
2-A
CC
U-1
61.
5 TR
MZF
2-A
CC
U-1
71.
5 TR
MZF
2-A
CC
U-1
81.
5 TR
MZF
2-A
CC
U-1
31.
5 TR
MZF
2-A
CC
U-1
41.
5 TR
MZF
2-A
CC
U-1
51.
5 TR
650X300
750X450
150MM DEPTH CONCRETE PEDESTAL
300MM DEPTH SLEEPER BEAM
150MM DEPTH CONCRETE PEDESTAL
300MM DEPTH CONCRETE PEDESTAL
300MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
150MM DEPTH CONCRETE PEDESTAL
BOD-4.565M FROM FFL
BOD-4.565M FROM FFL
BOD-4.565M FROM FFL
Ref. pipes atfloor level
LVAU - Local ventilation unitEVAU - Emergency ventilation unitEAD - Exhaust Air DuctSAD - Supply Air DuctSD - Supply DiffuserRD - Return DiffuserDSU - Duct Suspended UnitHW -Hiwall unit
LEGEND:
MZF
1-O
DU
-02
TYPICAL SIDE VIEW FOR
ODU OF HI-WALL UNIT
Architects & Consulting Engineers
'' Conjeevaram House'' 2nd Floor6-1-276, Padmaraonagar..
S e c u n d e r a b a d - 500 025Ph:27508968,Fax:040-27507733
Email: [email protected]
ACMV OVERHAUL HANGER LAYOUT FORTERRACE FLOOR