HST data sheets p.pdf

download HST data sheets p.pdf

of 122

Transcript of HST data sheets p.pdf

  • 8/14/2019 HST data sheets p.pdf

    1/122

    I21st CENTURY AERATION TECHNOLOGY

    HST INTEGRAL AERATION COMPRESSORS

    S2500 series

    S6000 series

    S9000 series

  • 8/14/2019 HST data sheets p.pdf

    2/122

  • 8/14/2019 HST data sheets p.pdf

    3/122

    HIGH

    SPEEDTECH

    HST INTEGRALS2500-1-L -4/5/6

  • 8/14/2019 HST data sheets p.pdf

    4/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    5/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 112 A / 69 kW

    Power supply 500 V / 50/60 Hz / 90 A / 69 kW

    Power supply 690 V / 50/60 Hz / 65 A / 69 kWAuxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speedelectrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, RL < 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, RL < 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 200

    Process air outlet DN 125

    *The outlet must have a back pressure valve minimum DN200

    Cooling air inlet 160 mm

    Cooling air outlet (cabinet) 160 mm

    C li i tl t ( t ) 160

  • 8/14/2019 HST data sheets p.pdf

    6/122

    Air QualityChemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3Chemical vapours according to IEC 721-3-3

    standardAve. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVELNoise pressure level (Lp,mean,1 m) ISO 9614-2 < 81 dB (A)

    THERMAL POWERThermal power 10...13% of input power

    WEIGHTTotal weight 750 kg

  • 8/14/2019 HST data sheets p.pdf

    7/122

    I S2500 -1-L Tol. (mm)

    H1 1273 10

    H2 1030 10

    H3 1890 5

    H4 510 5

    H5 1625 10

    L1 1420 10

    L2 550 10

    L3 485 2

    L4 280 10

    L5 190 10

    L6 382 5

    L7 395 10

    W1 830 5

    W2 245 10

    W3 208 5

    W4 200

    5

  • 8/14/2019 HST data sheets p.pdf

    8/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tion

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,nmeasurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault alarm reset

    Measure of inlet- and out ut

    ressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Zma n.

    K1-3 5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    9/122

    500115, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-L

    -10C, 101.13 kPa, RH 50 %

    20

    30

    40

    50

    60

    70

    80

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    970 1444 1933 2415

    Inlet Flow [m/h]

    2899 3370 3870

    40 kPa

    50 kPa60 kPa

  • 8/14/2019 HST data sheets p.pdf

    10/122

    500115, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-L

    0C, 101.13 kPa, RH 50 %

    20

    30

    40

    50

    60

    70

    80

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1000 1500 2007 2511

    Inlet Flow [m/h]

    3022 3518 4015

    40 kPa

    50 kPa60 kPa

  • 8/14/2019 HST data sheets p.pdf

    11/122

    500115, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-L

    +10C, 101.13 kPa, RH 50 %

    20

    30

    40

    50

    60

    70

    80

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1037 1556 2081 2607

    Inlet Flow [m/h]

    3125 3648 4163

    40 kPa

    50 kPa60 kPa

  • 8/14/2019 HST data sheets p.pdf

    12/122

    500115, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-L

    +20C, 101.13 kPa, RH 50 %

    20

    30

    40

    50

    60

    70

    80

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1067 1615 2163 2704

    Inlet Flow [m/h]

    3245 3778 4311

    40 kPa

    50 kPa60 kPa

  • 8/14/2019 HST data sheets p.pdf

    13/122

  • 8/14/2019 HST data sheets p.pdf

    14/122

    500115, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-L

    +40C, 101.13 kPa, RH 50 %

    20

    30

    40

    50

    60

    70

    80

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1141 1741 2326 2926

    Inlet Flow [m/h]

    3490 4080 4667

    40 kPa

    50 kPa60 kPa

  • 8/14/2019 HST data sheets p.pdf

    15/122

    HIGH

    SPEEDTECH

    HST INTEGRALS2500-1-H-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    16/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    17/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 135 A / 83 kW

    Power supply 500 V / 50/60 Hz / 108 A/ 83 kW

    Power supply 690 V / 50/60 Hz / 78 A/ 83 kWAuxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speedelectrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, RL < 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, RL < 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 200

    Process air outlet DN 125

    *The outlet must have a back pressure valve minimum DN200

    Cooling air inlet 160 mm

    Cooling air outlet (cabinet) 160 mm

    C li i l ( ) 160

  • 8/14/2019 HST data sheets p.pdf

    18/122

    Air QualityChemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3

    standardAve. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVELNoise pressure level (Lp,mean,1 m) ISO 9614-2 < 81 dB (A)

    THERMAL POWERThermal power 10...13% of input power

    WEIGHTTotal weight 750 kg

  • 8/14/2019 HST data sheets p.pdf

    19/122

    I S2500 -1-H Tol. (mm)

    H1 1273 10

    H2 1030 10

    H3 1890 5

    H4 510 5

    H5 1625 10

    L1 1420 10

    L2 550 10

    L3 485 2

    L4 280 10

    L5 190 10

    L6 382 5L7 395 10

    W1 830 5

    W2 245 10

    W3 208 5

    W4 200 5

  • 8/14/2019 HST data sheets p.pdf

    20/122

  • 8/14/2019 HST data sheets p.pdf

    21/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    -10C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    970 1444 1933 2415

    Inlet Flow [m/h]

    2899 3370 3870

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    22/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    0C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1000 1500 2007 2511

    Inlet Flow [m/h]

    3022 3518 4015

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    23/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    +10C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1037 1556 2081 2607

    Inlet Flow [m/h]

    3125 3648 4163

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    24/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    +20C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPowe

    r[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1067 1615 2163 2704

    Inlet Flow [m/h]

    3245 3778 4311

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    25/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    +30C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1119 1674 2244 2794

    Inlet Flow [m/h]

    3363 3935 4489

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    26/122

    500116, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-1-H

    +40C, 101.13 kPa, RH 50 %

    30

    40

    50

    60

    70

    80

    90

    1000 1500 2000 2500 3000 3500 4000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1141 1741 2326 2926

    Inlet Flow [m/h]

    3490 4080 4667

    60 kPa70 kPa80 kPa

  • 8/14/2019 HST data sheets p.pdf

    27/122

    HIGH

    SPEED

    TECH

    HST INTEGRALS2500-2-L -4/5

  • 8/14/2019 HST data sheets p.pdf

    28/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, typesS2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

  • 8/14/2019 HST data sheets p.pdf

    29/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONS

    Power supply 400 V / 50/60 Hz / 157 A/ 97 kW

    Power supply 500 V / 50/60 Hz / 126 A/ 97 kW

    Auxiliary supply As above / 10 A/ 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed electrical

    power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, R L< 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, R L< 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONS

    Process air inlet DN 200

    Process air outlet DN 125

    *The outlet must have a back pressure valve minimum DN200

    Cooling air inlet 160 mm

    Cooling air outlet (cabinet) 160 mm

  • 8/14/2019 HST data sheets p.pdf

    30/122

    Air Quality

    Chemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3Chemical vapours according to IEC 721-3-3

    standard

    Ave. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03Ammonia 1,0 / 3,0

    Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVEL

    Noise pressure level (Lp,mean,1 m

    ) ISO 9614-2 < 85 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHT

    Total weight 900 kg

  • 8/14/2019 HST data sheets p.pdf

    31/122

    I S2500 -2-L Tol.(mm)

    H1 1350 10

    H2 1016 10

    H3 1890 5

    H4 510 5

    H5 1602 10

    L1 1469

    10L2 549 10

    L3 535 2

    L4 324 10

    L5 190 10

    L6 432 5

    L7 395 10W1 830 5

    W2 245 10

    W3 200 5

    W4 200 5

    W5 930 5

  • 8/14/2019 HST data sheets p.pdf

    32/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tion

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X Y Z nmeasurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault, alarm,reset

    Measure of inlet-and out ut

    ressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X Y Zma n.

    K1-3,5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    33/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    -10C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    970 1444 1933 2415

    Inlet Flow [m/h]

    100 kPa90 kPa 80 kPa

    2899

  • 8/14/2019 HST data sheets p.pdf

    34/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    0C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1000 1500 2007 2511

    Inlet Flow [m/h]

    100 kPa 90 kPa 80 kPa

    3012

  • 8/14/2019 HST data sheets p.pdf

    35/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    +10C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1037 1556 2081 2607

    Inlet Flow [m/h]

    100 kPa90 kPa 80 kPa

    3125

  • 8/14/2019 HST data sheets p.pdf

    36/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    +20C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1067 1615 2163 2704

    Inlet Flow [m/h]

    100 kPa90 kPa 80 kPa

    3245

  • 8/14/2019 HST data sheets p.pdf

    37/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    +30C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1119 1674 2244 2794

    Inlet Flow [m/h]

    100 kPa90 kPa 80 kPa

    3357

  • 8/14/2019 HST data sheets p.pdf

    38/122

    500171, rev C All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-L

    +40C, 101.13 kPa, RH 50 %

    20

    40

    60

    80

    100

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1141 1741 2326 2911

    Inlet Flow [m/h]

    100 kPa90 kPa 80 kPa

    3485

  • 8/14/2019 HST data sheets p.pdf

    39/122

    HIGH

    SPEED

    TECH

    HST INTEGRALS2500-2-H -4/5

  • 8/14/2019 HST data sheets p.pdf

    40/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, typesS2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

  • 8/14/2019 HST data sheets p.pdf

    41/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONS

    Power supply 400 V / 50/60 Hz / 179 A/ 110 kW

    Power supply 500 V / 50/60 Hz / 143 A/ 110 kW

    Auxiliary supply As above / 10 A/ 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed electrical

    power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, R L< 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, R L< 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONS

    Process air inlet DN 200

    Process air outlet DN 125

    *The outlet must have a back pressure valve minimum DN200

    Cooling air inlet 160 mm

    Cooling air outlet (cabinet) 160 mm

    Cooling air outlet (motor) 160 mm

  • 8/14/2019 HST data sheets p.pdf

    42/122

    Air Quality

    Chemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3Chemical vapours according to IEC 721-3-3

    standard

    Ave. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03Ammonia 1,0 / 3,0

    Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVEL

    Noise pressure level (Lp,mean,1 m) ISO 9614-2 < 85 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHT

    Total weight 900 kg

  • 8/14/2019 HST data sheets p.pdf

    43/122

    I S2500 -2-H Tol.(mm)

    H1 1350 10

    H2 1016 10

    H3 1890 5

    H4 510 5

    H5 1602 10

    L1 1469 10

    L2 549 10

    L3 535 2

    L4 324 10

    L5 190 10

    L6 432 5

    L7 395 10W1 830 5

    W2 245 10

    W3 200 5

    W4 200 5

    W5 930 5

  • 8/14/2019 HST data sheets p.pdf

    44/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tionBoard

    VACON

    Basic

    Control

    Board

    MB

    controller

    X Y Z n

    measurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault, alarm,reset

    Measure of inlet-and out ut

    ressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X Y Z

    ma n.

    K1-3,5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    45/122

    500158, rev B All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-H

    -10C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    970 1444 1933 2415

    Inlet Flow [m/h]

    120 kPa110 kPa

    100 kPa

    2899

  • 8/14/2019 HST data sheets p.pdf

    46/122

    500158, rev B All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-H

    0C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1000 1500 2007 2511

    Inlet Flow [m/h]

    120 kPa 110 kPa100 kPa

    3012

  • 8/14/2019 HST data sheets p.pdf

    47/122

    500158, rev B All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-H

    +10C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1037 1556 2081 2607

    Inlet Flow [m/h]

    120 kPa110 kPa100 kPa

    3125

  • 8/14/2019 HST data sheets p.pdf

    48/122

  • 8/14/2019 HST data sheets p.pdf

    49/122

    500158, rev B All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-H

    +30C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1119 1674 2244 2794

    Inlet Flow [m/h]

    120 kPa110 kPa100 kPa

    3357

  • 8/14/2019 HST data sheets p.pdf

    50/122

    500158, rev B All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S2500-2-H

    +40C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    1000 1500 2000 2500 3000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    1141 1741 2326 2911

    Inlet Flow [m/h]

    120 kPa110 kPa100 kPa

    3485

  • 8/14/2019 HST data sheets p.pdf

    51/122

    HIGH

    SPEEDTECH

    HST INTEGRALS6000-1-L-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    52/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    53/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 260 A / 160 kWPower supply 500 V / 50/60 Hz / 208 A / 160 kWPower supply 690 V / 50/60 Hz / 151 A / 160 kW

    Auxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed

    electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, R L< 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, R L< 500Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 250

    Process air outlet DN 200

    *The outlet must have a back pressure valve minimum DN250

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

    Cooling air outlet (motor) 200 mm3

  • 8/14/2019 HST data sheets p.pdf

    54/122

    Air QualityChemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3standard

    Ave. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVELNoise pressure level (Lp,mean,1 m) ISO 9614-2 < 81 dB (A)

    THERMAL POWERThermal power 10...13% of input power

    WEIGHTTotal weight 1350 kg

  • 8/14/2019 HST data sheets p.pdf

    55/122

    I S6000-1-L Tol. (mm)

    H12065 10

    H2 1720 10

    H3 1365 10

    H4 310 5

    H5 1890 5

    L1 1780 5

    L2 830 10

    L3 594 2

    L4 484 5

    L5 375 10

    L6 250 10

    L7 1749 5

    W1 1210 2

    W2 370 10

  • 8/14/2019 HST data sheets p.pdf

    56/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tionBoard

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault alarm reset

    Measure of inlet- and out utressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    ma n.

    K1-3 5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    57/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    -10C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    2889 3867 4844 5778

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    77196726

  • 8/14/2019 HST data sheets p.pdf

    58/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    0C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3022 4015 5037 6015

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    80257022

  • 8/14/2019 HST data sheets p.pdf

    59/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    +10C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3111 4163 5215 6237

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    83197289

  • 8/14/2019 HST data sheets p.pdf

    60/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    +20C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3215 4311 5422 6489

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    86307556

  • 8/14/2019 HST data sheets p.pdf

    61/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    +30C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3363 4667 5615 6711

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    89637852

  • 8/14/2019 HST data sheets p.pdf

    62/122

    500117, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-L

    +40C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    3000 4000 5000 6000 7000 8000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPow

    er[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3481 4667 5852 6981

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    93338148

  • 8/14/2019 HST data sheets p.pdf

    63/122

    HIGH

    SPEED

    TECH

    HST INTEGRALS6000-1-H-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    64/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    65/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 310 A / 190 kW

    Power supply 500 V / 50/60 Hz / 247 A / 190 kW

    Power supply 690 V / 50/60 Hz / 179 A / 190 kW

    Auxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed

    electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, RL < 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, RL < 500Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 250

    Process air outlet DN 200

    *The outlet must have a back pressure valve minimum DN250

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

  • 8/14/2019 HST data sheets p.pdf

    66/122

    Air QualityChemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3standard

    Ave. / Max.[mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVELNoise pressure level (Lp,mean,1 m) ISO 9614-2 < 81 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHTTotal weight 1350 kg

  • 8/14/2019 HST data sheets p.pdf

    67/122

    I S6000 -1-H Tol. (mm)

    H1 2070 10

    H2 1730 10

    H3 1370 5

    H4 310 5

    H5 1890 10

    L1 1780 10L2 830 10

    L3 834 2

    L4 724 10

    L5 375 10

    L6 250 10

    L7 1989 5

    W1 1210 5

    W2 370 10

    W3 300 5

    W4 250 2

  • 8/14/2019 HST data sheets p.pdf

    68/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tionBoard

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault alarm reset

    Measure of inlet- and out utressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    ma n.

    K1-3 5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    69/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    -10C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    2889 3867 4844 5778

    Inlet Flow [m/h]

    60 kPa

    50 kPa

    40 kPa

    6726

  • 8/14/2019 HST data sheets p.pdf

    70/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    0C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3022 4015 5037 6015

    Inlet Flow [m/h]

    60 kPa50 kPa

    40 kPa

    7022

  • 8/14/2019 HST data sheets p.pdf

    71/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    +10C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3111 4163 5215 6237

    Inlet Flow [m/h]

    60 kPa50 kPa

    40 kPa

    7289

  • 8/14/2019 HST data sheets p.pdf

    72/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    +20C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3215 4311 5422 6489

    Inlet Flow [m/h]

    60 kPa 50 kPa

    40 kPa

    7556

  • 8/14/2019 HST data sheets p.pdf

    73/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    +30C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3363 4489 5615 6711

    Inlet Flow [m/h]

    60 kPa 50 kPa

    40 kPa

    7852

  • 8/14/2019 HST data sheets p.pdf

    74/122

    500118, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-1-H

    +40C, 101.13 kPa, RH 50 %

    40

    60

    80

    100

    120

    140

    160

    180

    200

    3000 4000 5000 6000 7000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3481 4667 5852 6981

    Inlet Flow [m/h]

    60 kPa 50 kPa

    40 kPa

    8148

  • 8/14/2019 HST data sheets p.pdf

    75/122

    HIGH

    SPEED

    TECH

    HST INTEGRALS6000-2-L-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    76/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    77/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 390 A / 240 kW

    Power supply 500 V / 50/60 Hz / 312 A / 240 kW

    Power supply 690 V / 50/60 Hz / 226 A / 240 kWAuxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed

    electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, RL < 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, RL < 500Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 250

    Process air outlet DN 200

    *The outlet must have a back pressure valve minimum DN250

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

    Cooling air outlet (motor) 200 mm

  • 8/14/2019 HST data sheets p.pdf

    78/122

  • 8/14/2019 HST data sheets p.pdf

    79/122

    I S6000 2-L Tol. (mm)

    H1 2070 10

    H2 1730 10

    H3 1370 5

    H4 310 5

    H5 1890 10

    L1 1780

    10L2 830 10

    L3 834 2

    L4 724 10

    L5 375 10

    L6 250 10

    L7 1989 5

    W1 1210 5

    W2 370 10

    W3 300 5

    W4 250 2

  • 8/14/2019 HST data sheets p.pdf

    80/122

    Block Diagram

    Processair

    outlet

    Processair nlet

    O tion

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka e alarm

    AMB fault alarm reset

    Measure of inlet- and out utressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    ma n.

    K1-3 5-6

    Hi gh SpeedUnit

  • 8/14/2019 HST data sheets p.pdf

    81/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    -10C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    2889 3867 4844 5807

    Inlet Flow [m/h]

    100 kPa

    90 kPa

    80 kPa

    6726

  • 8/14/2019 HST data sheets p.pdf

    82/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    0C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3022 4015 5037 6015

    Inlet Flow [m/h]

    100 kPa

    90 kPa

    80 kPa

    7022

  • 8/14/2019 HST data sheets p.pdf

    83/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    +10C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3111 4163 5215 6237

    Inlet Flow [m/h]

    100 kPa

    90 kPa

    80 kPa

    7289

  • 8/14/2019 HST data sheets p.pdf

    84/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    +20C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3215 4311 5422 6489

    Inlet Flow [m/h]

    100 kPa90 kPa

    80 kPa

    7556

  • 8/14/2019 HST data sheets p.pdf

    85/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    +30C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3363 4489 5615 6711

    Inlet Flow [m/h]

    100 kPa90 kPa

    80 kPa

    7852

  • 8/14/2019 HST data sheets p.pdf

    86/122

    500119, rev D All rights reserved

    High Speed Tech Oy Ltd

    HST INTEGRAL S6000-2-L

    +40C, 101.13 kPa, RH 50 %

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputPo

    wer[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3481 4667 5852 6981

    Inlet Flow [m/h]

    100 kPa90 kPa

    80 kPa

    8148

  • 8/14/2019 HST data sheets p.pdf

    87/122

    HIGH

    SPEED

    TECH

    HST INTEGRALS6000-2-H-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    88/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU Machinery Directive (Directive 89/392/EU)

    EU Low-Voltage Equipment Directive (73/23/EU)

    EU Directitive on Electromagnetic Compatibility (89/336/EU)

  • 8/14/2019 HST data sheets p.pdf

    89/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 390 A / 240 kWPower supply 500 V / 50/60 Hz / 312 A / 240 kW

    Power supply 690 V / 50/60 Hz / 226 A / 240 kW

    Auxiliary supply As above / 10 A / 1 kW

    Product has been designed and manufactured to be connected to industrial network in

    accordance with EN61800-3 standard. (EMC product standard for adjustable speed

    electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, RL < 500Binary inputs 24 Vdc

    Analogue output 4-20 mA, RL < 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONS

    Process air inlet DN 250

    Process air outlet DN 200

    *The outlet must have a back pressure valve minimum DN250

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

    Cooling air outlet (motor) 200 mm

  • 8/14/2019 HST data sheets p.pdf

    90/122

    Air Quality

    Chemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3standard

    Ave. / Max.[mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0

    Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVEL

    Noise pressure level (Lp,mean,1 m) ISO 9614-2 < 83 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHTTotal weight 1500 kg

  • 8/14/2019 HST data sheets p.pdf

    91/122

    I S6000 2-H Tol. (mm)

    H1 2070 10H2 1730 10

    H3 1370 5

    H4 310 5

    H5 1890 10

    L1 1780 10

    L2 830 10

    L3 834 2

    L4 724 10

    L5 375 10

    L6 250 10

    L7 1989 5

    W1 1210 5

    W2 370 10

    W3 300 5

    W4 250 2

  • 8/14/2019 HST data sheets p.pdf

    92/122

    Block Diagram

    Processair

    outlet

    Processair inlet

    O tion

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customerserial

    comm.

    Customer

    terminals

    Coolin air filter locka ealarm

    AMB fault alarm reset

    Measure of inlet- and out utressure

    Blowoff valve control

    Pt-100tem erature

    measurementmotor

    windin and inlet air

    Control panel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    ma n.

    K1-3 5-6

    H igh SpeedUni t

  • 8/14/2019 HST data sheets p.pdf

    93/122

    HST INTEGRAL S6000-2-H

    -10C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    Inpu

    tPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    2889 3867 4844 5807

    Inlet Flow [m/h]

  • 8/14/2019 HST data sheets p.pdf

    94/122

    HST INTEGRAL S6000-2-H

    0C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    3022 4015 5037 6015

    Inlet Flow [m/h]

    120 kPa

  • 8/14/2019 HST data sheets p.pdf

    95/122

    HST INTEGRAL S6000-2-H

    +10C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressu

    3111 4163 5215 6237

    Inlet Flow [m/h]

    120 kPa 110

  • 8/14/2019 HST data sheets p.pdf

    96/122

    HST INTEGRAL S6000-2-H

    +20C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    Input

    Power[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure R

    3215 4311 5422 6489

    Inlet Flow [m/h]

    120 kPa 110 kPa

  • 8/14/2019 HST data sheets p.pdf

    97/122

    HST INTEGRAL S6000-2-H

    +30C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    Inpu

    tPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3363 4489 5615 6711

    Inlet Flow [m/h]

    120 kPa 110 kPa 100 kPa

  • 8/14/2019 HST data sheets p.pdf

    98/122

    HST INTEGRAL S6000-2-H

    +40C, 101.13 kPa, RH 50 %

    100

    120

    140

    160

    180

    200

    220

    240

    260

    InputPower[kW]

    Compressor tests according to ISO 5389

    Scale accuracy 3%

    Pressure Rise

    3481 4667 5852 6981

    Inlet Flow [m/h]

    120 kPa 110 kPa 100 kPa

  • 8/14/2019 HST data sheets p.pdf

    99/122

    HIGH

    SPEEDTECH

    HST INTEGRAL

    S9000-1-L- 4/5/6

  • 8/14/2019 HST data sheets p.pdf

    100/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU M hi Di ti (Di ti 89/392/EU)

  • 8/14/2019 HST data sheets p.pdf

    101/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 310 A / 190 kW

    Power supply 500 V / 50/60 Hz / 247 A / 190 kW

    Power supply 690 V / 50/60 Hz / 179 A / 190 kW

    Auxiliary supply As above / 10 A / 1 kW

    Product has been designed to be connected to industrial network in accordance with EN61800-3

    standard. (EMC product standard for adjustable speed electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, R L< 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, R L< 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONS

    Process air inlet DN 400

    Process air outlet DN 300

    *The outlet must have a back pressure valve minimum DN400

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

    Cooling air outlet (motor) 250 mm

  • 8/14/2019 HST data sheets p.pdf

    102/122

    Air Quality

    Chemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3

    standard

    Ave. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVEL

    Noise pressure level (Lp,mean,1 m) ISO 9614-2 < 83 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHT

    Total weight 1700 kg

  • 8/14/2019 HST data sheets p.pdf

    103/122

    I S9000 -1 Tol.

    (mm)

    H1 2252 10

    H2 1857 10

    H3 1443 10

    H4 310 5

    H5 2000 5

    L1 1780 5L2 830 10

    L3 890 2

    L4 747 5

    L5 375 10

    L6 250 10

    L7 2045 10

    W1 1210 2

    W2 370 10

    W3 310 5

    W4 320 5

    W5 400 5

  • 8/14/2019 HST data sheets p.pdf

    104/122

    Block Diagram

    Process air

    outlet

    Process air inlet

    Option

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customer serial

    comm.

    Customer

    terminals

    Cooling air filter blockage alarm

    AMB fault, alarm,reset

    Measure of inlet- and output

    pressure

    Blow off valve control

    Pt-100 temperature

    measurement motor

    winding and inlet air

    Controlanel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    magn.

    K1-3,5-6

    High Speed Unit

  • 8/14/2019 HST data sheets p.pdf

    105/122

    HST INTEGRAL S9000-1-L

    -10C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    Pressure Rise

    3863 4829 5794 6760 7726 8691 9657

    Inlet Flow [m/h]

    60 kPa50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    106/122

    HST INTEGRAL S9000-1-L

    0C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    Pressure Rise

    4012 5015 6018 7022 8025 9037 10031

    Inlet Flow [m/h]

    60 kPa 50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    107/122

    HST INTEGRAL S9000-1-L

    +10C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4164 5205 6246 7287 8328 9369 10410

    Inlet Flow [m/h]

    Pressure Rise60 kPa 50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    108/122

    HST INTEGRAL S9000-1-L

    +20C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4320 5400 6480 7560 8640 9720 10800

    Inlet Flow [m/h]

    Pressure Rise60 kPa 50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    109/122

    HST INTEGRAL S9000-1-L

    +30C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4483 5604 6725 7846 8967 10088 11209

    Inlet Flow [m/h]

    Pressure Rise60 kPa 50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    110/122

    HST INTEGRAL S9000-1-L

    +40C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4659 5824 6988 8153 9318 10482 11647

    Inlet Flow [m/h]

    Pressure Rise60 kPa 50 kPa 40 kPa

  • 8/14/2019 HST data sheets p.pdf

    111/122

    HIGH

    SPEED

    TECH

    HST INTEGRAL

    S9000-1-H-4/5/6

  • 8/14/2019 HST data sheets p.pdf

    112/122

    EC DECLARATION OF CONFORMITY

    We

    Manufacturer: High Speed Tech Oy Ltd

    Address: Teollisuuskatu 9

    53600 Lappeenranta

    FINLAND

    Herewith declares that

    HST Integral turbocompressors, types

    S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,

    S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,

    S9000 -1-L, S9000 -1-H

    is in conformity with the provisions of

    EU M hi Di ti (Di ti 89/392/EU)

  • 8/14/2019 HST data sheets p.pdf

    113/122

    TECHNICAL SPECIFICATIONS

    MAINS CONNECTIONSPower supply 400 V / 50/60 Hz / 390 A / 240 kW

    Power supply 500 V / 50/60 Hz / 312 A / 240 kW

    Power supply 690 V / 50/60 Hz / 226 A / 240 kW

    Auxiliary supply As above / 10 A / 1 kW

    Product has been designed to be connected to industrial network in accordance with EN61800-3

    standard. (EMC product standard for adjustable speed electrical power drive system.)

    CONTROL CONNECTIONS

    Analogue inputs 4-20mA, R L< 500

    Binary inputs 24 Vdc

    Analogue output 4-20 mA, R L< 500

    Binary outputs 48 Vac / dc / 2 A

    PIPING CONNECTIONSProcess air inlet DN 400

    Process air outlet DN 300

    *The outlet must have a back pressure valve minimum DN400

    Cooling air inlet 250 mm

    Cooling air outlet (cabinet) 250 mm

    Cooling air outlet (motor) 250 mm

  • 8/14/2019 HST data sheets p.pdf

    114/122

    Air Quality

    Chemical vapours IEC 721-3-3

    Mechanical particles IEC 721-3-3

    Chemical vapours according to IEC 721-3-3

    standard

    Ave. / Max.

    [mg/m]

    Sulphur dioxide 0,3 / 1,0

    Hydrogen sulphide 0,1 / 0,5

    Chlorine 0,1 / 0,3

    Hydrogen chloride 0,1 / 0,5

    Hydrogen fluoride 0,01 / 0,03

    Ammonia 1,0 / 3,0Ozone 0,05 / 0,1

    Nitrogen oxides 0,5 / 1,0

    NOISE LEVEL

    Noise pressure level (Lp,mean,1 m) ISO 9614-2 < 83 dB (A)

    THERMAL POWER

    Thermal power 10...13% of input power

    WEIGHT

    Total weight 1700 kg

  • 8/14/2019 HST data sheets p.pdf

    115/122

    I S9000 -1 Tol.

    (mm)

    H1 2252 10H2 1857 10

    H3 1443 10

    H4 310 5

    H5 2000 5

    L1 1780 5

    L2 830 10

    L3 890 2

    L4 747 5

    L5 375 10

    L6 250 10

    L7 2045 10

    W1 1210 2

    W2 370 10

    W3 310 5

    W4 320 5

    W5 400 5

    W6 1350 2

  • 8/14/2019 HST data sheets p.pdf

    116/122

    Block Diagram

    Process air

    outlet

    Process air inlet

    Option

    Board

    VACON

    Basic

    Control

    Board

    MB

    controller

    X,Y,Z,n

    measurement

    Customer serial

    comm.

    Customer

    terminals

    Cooling air filter blockage alarm

    AMB fault, alarm,reset

    Measure of inlet- and output

    pressure

    Blow off valve control

    Pt-100 temperature

    measurement motor

    winding and inlet air

    Control anel

    Control cabinet

    220Vac

    F5-6

    F3-4

    5

    2

    K4

    U1

    L11

    1

    X,Y,Z

    magn.

    K1-3,5-6

    High Speed Unit

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    117/122

    HST INTEGRAL S9000-1-H

    -10C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    Pressure Rise

    3863 4829 5794 6760 7726 8691 9657

    Inlet Flow [m/h]

    80 kPa 70 kPa 60 kPa

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    118/122

    HST INTEGRAL S9000-1-H

    0C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    Pressure Rise

    4012 5015 6018 7022 8025 9037 10031

    Inlet Flow [m/h]

    80 kPa 70 kPa 60 kPa

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    119/122

    HST INTEGRAL S9000-1-H

    +10C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4164 5205 6246 7287 8328 9369 10410

    Inlet Flow [m/h]

    Pressure Rise80 kPa 70 kPa 60 kPa

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    120/122

    HST INTEGRAL S9000-1-H

    +20C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4320 5400 6480 7560 8640 9720 10800

    Inlet Flow [m/h]

    Pressure Rise80 kPa 70 kPa 60 kPa

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    121/122

    HST INTEGRAL S9000-1-H

    +30C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Calculated data

    Scale accuracy 3%

    4483 5604 6725 7846 8967 10088 11209

    Inlet Flow [m/h]

    Pressure Rise80 kPa 70 kPa 60 kPa

    Calculated data

  • 8/14/2019 HST data sheets p.pdf

    122/122

    HST INTEGRAL S9000-1-H

    +40C, 101.13 kPa, RH 50 %

    60

    80

    100

    120

    140

    160

    180

    200

    220

    240

    260

    4000 5000 6000 7000 8000 9000 10000 11000

    Inlet Flow [Nm/h]

    0C, 101.32kPa, RH 0%

    InputP

    ower[kW]

    Scale accuracy 3%

    4659 5824 6988 8153 9318 10482 11647

    Inlet Flow [m/h]

    Pressure Rise80 kPa 70 kPa 60 kPa