GE Energy Steam Turbine First Printed April 2001 GEK 107568 a These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes the matter should be referred to the GE Company. © 2001 GENERAL ELECTRIC COMPANY General Specifications Removable Blanket Insulation for Steam Turbines Revised November 2004 

Transcript of GEK 107568a

Page 1: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 1/25

GE EnergSteam Turbin

First Printed April 20GEK 10756

General Specifications

Removable Blanket Insulation for Steam Turbines

Revised November 200

Page 2: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 2/25

GEK 10756 8a  General Specifications 

I. INTRODUCTION 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

II. HIGH TEMPERATURE BLANKET 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A. Heat Retention Filler - High Temperature 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B. Thickness Of Blanket Insulation (Maximum Allowed) 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

C. Materials - High Temperature 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D. Envelope - High Temperature 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E. Low Temperature Blankets 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

F. Heat Retention Filler - Low Temperature 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

G. Materials - Low Temperature 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H. Envelope - Low Temperature 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

J. Tufting and Securements 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

III. STEAM TURBINE INSTALLATION INSTRUCTIONS - FIT OF BLANKETS 6. . . . . . . . . . . .

IV. INSTALLATION DRAWINGS FOR TURBINE 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 3/25

General Specifications GEK 10756

I. INTRODUCTION

This specification applies to turbine shell blankets supplied by the Power Systems Sourcing Operation

PSSO. They will be Tailor-Made removable insulation and be of such quality as to have long life, provid

reasonable care is used in handling. The maximum weight of a blanket pad is to be approximately 80 lb

Use of material other than specified must be approved by the Schenectady Turbine-Generator Factory PSS

All materials shall be ASBESTOS-FREE.

II. HIGH TEMPERATURE BLANKETS

The high temperature blankets are for use as the first layer next to the turbine shell where the mettemperature will be 650°F or above.

A. HEAT RETENTION FILLER - HIGH TEMPERATURE

The high temperature blanket pads are to contain a filler composed of one or more layers of a spu

refractory fiber of approximately 8 lbs/ft3 density made in blanket form. The blanket is to be of su

thickness that the temperature between the high and low temperature pads is below 650°F.

The heat retention material drawings will give the hot surface temperature of the areas to be insulateThe thickness in Section II. B. are used in design to provide sufficient clearance around power pla

equipment and turbine metal lagging.

B. THICKNESS OF BLANKET WITH 80°F AMBIENT TEMPERATURE

Page 4: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 4/25

GEK 107568a General Specifications 

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

Á  Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

METAL TEMPERATURE

Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

Á  Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

MAX COLD SURFACE

Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

Á  Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

*BLANKET

THICKNESS

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

1050-1000 Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140 Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

5.0″ DL

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

999-950Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

4.5″ DL

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

949-900Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

4.0″ DL

Á Á Á Á Á Á Á Á Á Á Á  

899-800Á Á Á Á Á Á Á Á Á Á  

140Á Á Á Á Á Á Á Á  

4.0″ DLÁ Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

799-650Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

3.5″ DLÁ Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

649-500 Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140 Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

3.0″ DL

Á Á Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á Á  

499 and belowÁ Á Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á Á Á  

140Á Á Á Á Á Á Á Á  

Á Á Á Á Á Á Á Á  

2.5″ 

DL*DL = Double Layer - Blanket system must be manufactured with a high temperature

blanket and a low temperature blanket.

Thickness based on the following criteria:

1. 80°F ambient

2. 2 mph wind

3. .80 emissivity

Ceramic Fiber #8

1. 300F-.282 (BTU *in\hr* ft {degree F}

Page 5: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 5/25

General Specifications GEK 10756

D. ENVELOPE - HIGH TEMPERATURE

The heat retention filler is to be enclosed in an envelope of inconel knitted wire mesh. The envelope sh

consist of knitted wire mesh on both sides. The envelope will be sewn together with fiberglass coat

stainless steel thread or with flange seams stapled together with stainless steel staples. Approved knitt

wire mesh is .011 diameter wire, 5 to 7 courses per inch.

E. LOW TEMPERATURE BLANKETS

The low temperature blankets are for use where the temperature is below 500°F.

F. HEAT RETENTION FILLER -LOW TEMPERATURE

The low temperature blankets are to contain a filler composed of one or more layers in blanket form

The material is to be approximately 9 lbs/ft3 density. The blanket is to be of a thickness that will gi

a cold surface temperature of 140°F MAXIMUM WITH AN 80°F AMBIENT. UNLESS OTHERWIS

SPECIFIED ON ORDERING DRAWING.

NOTE

Use only one type filler material throughout the temperature range.

G. MATERIALS - LOW TEMPERATURE

H. ENVELOPE - LOW TEMPERATURE

The heat retention material filler is to be enclosed in an envelope. Lagging fabric is required on the h

Page 6: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 6/25

III. STEAM TURBINE GENERAL INSTALLATION INSTRUCTIONS - FIT OF BLANKETS

A. ObjectiveThe purpose of this document is to assist the contractor through the installation process. Extreme care

and supervision is recommended to ensure proper application and coverage of the materials.

B. Inventory of Materials

All materials are to be stored in a dry environment. Check the materials received in accordance with

the packing list provided by the Supplier. Contractor shall identify the number of cartons\skids

supplied compared to the packing list. Contact the Supplier immediately if any discrepancies occur.

C. Identification of Materials

Contractor shall identify where all materials are to be installed using the following guidelines:

• Removable blankets on turbine shells, (check blanket items comparing them to the packing list)

• Removable stainless steel covers\removable insulation blankets on valve heads and crossover

flanges

• Accessory items (studs with nails and washers, welding pins, etc.)

• Modification kit and tools (includes insulation, fabric, mesh, etc.)

D. Fit of Materials

GEK 107568a General Specifications 

Page 7: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 7/25

IV. INSTALLATION DRAWINGS FOR TURBINE

Drawings include the tag numbers, location, application details, and installation methods.

Drawings include proper size and thickness for steam pipes, valve body, crossover pipe, and gland steam

condenser.

V. INSTALLATION OF REMOVABLE BLANKETS ON STEAM TURBINE

A. Inner Layer Lower Half Blankets

1. Prepare scaffolding for the lower half and the horizontal joint.

2. Layout all lower half blankets along the grating or floor of left and right sides of the machine. Follow

drawing layout legend for tagging information.

3. Install 1/2″  x 9″  threaded stud with nail into the threaded nut on the turbine casing. See detail

drawing for removable blankets.

4. Install studs in order to prevent air gaps or sagging of blankets. Quantity shall be at the discretionof the installing contractor.

5. Install loose cerawool insulation between and behind joint bolts. See photos 1 and 2.

6. Install 1/2″  to 1″ cerawool around the horizontal joint bolts. See photos 3 and 4.

General Specifications GEK 107568a 

Page 8: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 8/25

GEK 107568a General Specificatio

7. Inner layer of the blanket system shall be installed in accordance with the assembly sequence

installation drawing. Install washer onto each nail temporarily, on each blanket. When all of th

blankets line up properly, secure washers firmly and snug the Blankets to the casing. See photos

and 6.

8. If small gaps occur, stuff them with scrap ceramic wool and secure with 16 gauge stainless steel

wire.

9. Using the same studs on the outer layer, install the second layer of blankets the same way as on t

first layer.

B. Inner Layer Upper Half Blankets

1. Layout all upper half blankets along the grating or floor of left and right sides of the machine. Follo

drawing layout legend for tagging information.

2. Install 1/2″  x 9″  threaded stud with nail into the threaded nut on the turbine casing. See deta

drawing for removable blankets.

3. Install loose cerawool insulation between and behind joint bolts. See photo 2.

4. Install 1″ cerawool around the horizontal joint bolts. See photos 3 and 4.

5. Inner layer of the blanket system shall be installed in accordance with the assembly sequence

detail drawing. Install washer onto each nail temporarily, on each blanket. When all of the blanke

line up properly, secure washers firmly and snug the blankets to the casing.

Page 9: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 9/25

General Specifications GEK 107568a 

D. Outer Layer Of Lower Half Blankets

1. Outer layer of the blanket system shall be installed in accordance with the assembly sequence on

installation drawing. Install washer onto each nail temporarily, on each blanket. When all of the

blankets line up properly, secure washers firmly and snug the insulation to the inner layer.

2. If small gaps occur, stuff them with scrap ceramic wool and secure with 16 gauge stainless steel tie

wire.

3. Make sure all blankets are installed without any gaps and secured firmly next to the turbine casing

or inner layer.

E. Outer Layer Of Upper Half Blankets

1. Outer layer of the blanket system shall be install in accordance with the assembly sequence on detail

drawing. Install washer onto the nail temporarily on each blanket. When all of the blankets line up

properly, secure washers firmly and snug the insulation to the casing.

2. If small gaps occur, stuff them with scrap ceramic wool and secure with 16 gauge stainless steel tie

wire.

3. Make sure all blankets are installed without any gaps and secured firmly next to the inner layer.

4. See photos 10 and 11.

F. Outer Layer Of Horizontal Joint Blankets

Page 10: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 10/25

GEK 107568a General Specificatio

4. Layout all blankets along the floor to the left and right sides of the hood. Follow drawing layo

legend for tagging information.

5. Weld pins to the exhaust hood, not less than four per blanket.

6. Blankets shall be installed in accordance with the assembly sequence on the installation drawing

Install a washer onto each pin temporarily, on each blanket. When all of the blankets line up proper

secure washers firmly and lace with 16 gauge stainless steel wire.

Page 11: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 11/25

General Specifications GEK 107568a 

VI. PHOTOS

Page 12: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 12/25

GEK 107568a General Specificatio

Page 13: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 13/25

General Specifications GEK 107568a 

Page 14: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 14/25

Page 15: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 15/25

General Specifications GEK 107568a 

Page 16: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 16/25

GEK 107568a General Specificatio

Page 17: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 17/25

General Specifications GEK 107568a 

Page 18: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 18/25

GEK 107568a General Specificatio

Page 19: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 19/25

General Specifications GEK 107568a 

Page 20: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 20/25

GEK 107568a General Specificatio

Page 21: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 21/25

General Specifications GEK 107568a 

Page 22: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 22/25

GEK 107568a General Specification

Page 23: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 23/25

General Specifications GEK 107568a 

Page 24: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 24/25

Page 25: GEK 107568a

8/4/2019 GEK 107568a

http://slidepdf.com/reader/full/gek-107568a 25/25