Fm Spaf140c en Cda

download Fm Spaf140c en Cda

of 56

Transcript of Fm Spaf140c en Cda

  • 8/3/2019 Fm Spaf140c en Cda

    1/56

    SPCF 1D15

    TRIP

    RESET

    STEP

    0024C

    PROGRAM

    IRFfU

    f

    df

    dt

    SGR

    SGB

    SGF

    [ ]nf

    U /100 M, 500 Vdc

    Electromagnetic Compatibility Tests *)

    High-frequency (1 MHz) burst disturbance testIEC 60255-22-1- common mode 2.5 kV - differential mode 1.0 kV Electrostatic discharge test IEC 60255-22-2 andIEC 61000-4-2- contact discharge 6 kV - air discharge 8 kV Fast transient disturbance test IEC 60255-22-4and IEC 61000-4-4- power supply 4 kV

    - I/O ports 2 kV

    Mechanical environmental tests

    Vibration test, IEC 60255-21-1 class 2Chock/bump test, IEC 60255-21-2 class 2Seismic test, IEC 60255-21-3 class 2

    Environmental conditions

    Service temperature range -10... +55CTransport and storage temperature range -40...+70CTemperature influence 0.05/frequency measurement

    in the range -10C+55C

  • 8/3/2019 Fm Spaf140c en Cda

    9/56

    9

    Example of

    application

    Example:Frequency relaySPAF 140 C usedfor generator andturbine protection

    Normally, the frequency of the generator is de-termined by the external network. If power con-sumption exceeds the power generated, therewill be a power deficiency and, as a result, a fre-quency decline. As the frequency drops, theregulator tries to boost the capacity of the gen-erator prime mover, causing the frequency toreturn to normal. Correspondingly, if powerconsumption is smaller than power generation,the frequency of the network increases.

    Unless it is possible to increase the capacity ofthe prime mover so that it correspond to theload, the power deficiency remains permanentand the network frequency starts declining.Under normal conditions, the rate of the fre-quency drop automatically slows down, and mayeven stop, because power consumption gener-ally decreases as the frequency falls (compare

    pump and squirrel-cage motor). Sometimes, forinstance in island operation, the network fre-quency can drop to a level that is hazardous tothe turbine of the generator. Mechanical vibra-tion of the turbine blades due to underfrequencymay break the blades.

    A moderate level of overfrequency does notdamage the generator but, for instance, a sud-den load disconnection may cause the systemto accelerate so fast that the speed regulationdoes not respond fast enough, and the genera-tor and the prime mover reach dangerous rota-tional speeds.

    The frequency relay SPAF 140 C can be usedto protect the generator and the turbine againstboth overfrequency and underfrequency.

    IRFSS1TS1SS2TS2SS3TS3SS4

    TS4I/OBS1BS2BS3BS4BS5

    U1

    4

    f

    4

    df/dt

    48 47 46 45 23 22 11 10

    BS4 BS3 BS2 BS1

    X0 63 13 14 1662 61

    Uaux

    + -

    =

    ~_

    + (~)

    - (~)

    70 71 72 68 69 85 86 87 88

    IRF SS1 TS1 TS2SERIALPORT(SPA)

    + + +

    SPA-ZC_

    Rx Tx

    U3

    +

    U2

    100V

    Not

    Used

    a

    n

    d

    N

    A

    +

    01

    -

    -

    +

    0

    +

    1

    Alarm Alarm

    Fig. 4. Frequency relay SPAF 140 C used for the protection of a generator and a turbine.

  • 8/3/2019 Fm Spaf140c en Cda

    10/56

    10

    Four protection stages, two signalling and twotripping, are used in the example described.Stage 2 produces an alarm signal, if the fre-quency exceeds the rated frequency, and stage3, correspondingly, if the frequency falls belowthe rated frequency. The selected alarm limitsallow the generator and the turbine to operatefor a long time with the concerned frequency,without any risk of being damaged.

    Should the frequency decrease or increase to adangerous level, the relay provides a trip signal.The protection also includes a blocking inputwhich can be used for blocking the relay opera-tion, for instance, during the start of the gen-erator.

    The start values and operate times of the pro-tection stages and the timers controlling the in-dividual circuit breakers are shown in Fig. 5.The designations used in Fig. 5 refer to Fig. 4.

    Stage Operate Delay Timer Relay output Functionvalue (Hz)

    1 53.0 0.30 t1 TS1 Tripping2 51.5 1.00 t2 SS1 Overfrequency alarm3 48.5 1.00 t3 TS2 * Underfrequency alarm4 47.0 0.30 t4 TS1 Tripping

    *)The trip contact TS2 is used for underfrequency alarm, because only one trip contact isrequired for the protection.

    Fig. 5. Setting of the protection stages of frequency relay SPAF 140 C used for the protection of agenerator and a turbine.

    In the case described in the example the switches of the frequency relay SPAF 140 C can be set asfollows:

    Setting of t, relay module SPCF 1D15

    Switch- Serial comm. Checksum Operationgroup parameter

    SGF1 S84 1 Only frequency functionSGF2 S85 1 Only frequency functionSGF3 S86 1 Only frequency functionSGF4 S87 1 Only frequency functionSGF5 S88 255 Outputs continuously operatedSGF6 S89 2 TS1 connected to LED indicator TRIPSGF7 S90 0 Un = 100 V

    SGB1 S91 15 Blocking via external control signal BS1SGB2 S92 0 External control signal BS2 not in useSGB3 S93 0 External control signal BS3 not in useSGB4 S94 0 External control signal BS4 not in useSGB5 S95 0 External control signal BS5 not in useSGB6 S96 15 Undervoltage blocking to all stages

    SGR1 S97 2 Overfrequency trip signal to trip contact TS1SGR2 S98 0 Not in useSGR3 S99 1 Underfrequency alarm signal to signal contact SS1SGR4 S100 0 Not in useSGR5 S101 8 Underfrequency alarm signal to trip contact TS2SGR6 S102 0 Not in useSGR7 S103 2 Underfrequency trip signal to trip contact TS1SGR8 S104 0 Not in useSGR9 S105 0 No recovery function

  • 8/3/2019 Fm Spaf140c en Cda

    11/56

    11

    Testing The relay should be subjected to regular tests inaccordance with national regulations and in-structions. The manufacturer recommends aninterval of five years between the tests.

    The test should be carried out as a primary test,which includes the entire protection arrange-ment, from the instrument transformers to thecircuit breakers.

    The test can also be carried out as a secondaryinjection test. Then the relay has to be discon-nected during the test procedure. However, it isrecommended to check the function of the sig-nal and trip circuits as well.

    Note!Make sure that the secondary circuits of thecurrent transformers under no condition openor are open, when the relay is disconnected andduring the test procedure.

    The test is recommended to be carried out us-ing the normal setting values of the relay andthe energizing inputs used. When required, thetest can be extended to include more settingvalues.

    As the settings of the relay modules affect theoperation of the relay (overfrequency/under-frequency relay) and thus also the test proce-dure, these instructions describe the general fea-tures of the test procedure. The test procedurepresented here applies to the underfrequency re-lay. A voltage supply unit allowing voltage andfrequency to be regulated is recommended tobe used. In addition, instruments for measur-ing voltage, frequency and time are required.

    During the test procedure the relay records fre-quencies, rates of change of frequency, voltagesand relay operations. If the recorded data is usedfor the collection of information for longer timeperiods (for example, AR counters), these re-gisters should be read before the test procedureis started. After the test the registers are resetand, if required, the readings of the AR counterscan be restored.

    The relay settings may have to be changed dur-

    ing testing. A PC program is recommended tobe used to read the relay settings before the testis started.

    Testing of thecombined frequencyand rate of change offrequency relaymodule SPCF 1D15

    General

    The protection stages are tested with respect to:- start value- trip time- trip indication, output relay operation

    Start value Test the start value by gradually dropping thefrequency, starting from the rated value, untilthe relay starts. Record the frequency requiredfor starting. The value should be within the per-mitted tolerances.

    If the resetting value is to be tested as well, dropthe frequency, until the relay starts, and then in-crease the frequency again, until the relay resets.

    When multi-stage protection relays are tested,the operation of the higher-set stages may cause

    problems to the testing of lower-set stages. Thenit is generally necessary to delay the operationof the higher-set stages by changing the settingvalues, or totally block the operation of thehigher stages by reconfiguring the SGR switches.In such a case it is recommended to start thetest from the lowest stage and then proceed tohigher-set stages. The advantage of this methodis that the original settings of the stages really

    are restored, because otherwise the test cannotbe carried out successfully.

    Trip time Apply a voltage of rated frequency to the relay.Then drop the frequency of the voltage to a valuebelow the setting value. The frequency of thesupply voltage should be such that the differ-ence between the trip level and the frequencyof the supply voltage is about twice the differ-ence between the rated frequency and the trip

    level. However, the absolute value of the rate ofchange of frequency must not exceed 70 Hz/s,because the relay perceives such a situation as a

    disturbance and delays tripping by two cycles.The operate time is the time from the momentthe frequency starts changing, until the relayoperates. The accuracy of the operate timesshould be within the permitted tolerances.

    The resetting time is the time measured from

    the moment the current switch is opened, untilthe relay resets.

  • 8/3/2019 Fm Spaf140c en Cda

    12/56

    12

    Maintenance

    and repairs

    When the protection relay is used under theconditions specified in "Technical data", it re-quires practically no maintenance. The relayincludes no parts or components that are sensi-tive to physical or electrical wear under normaloperating conditions.

    Should the temperature and humidity at theoperating site differ from the values specified,or the atmosphere contain chemically activegases or dust, the relay should be visually in-spected in association with the secondary test-ing of the relay. This visual inspection shouldfocus on:

    - Signs of mechanical damage to relay case andterminals

    - Collection of dust inside the relay case; removewith compressed air

    - Signs of corrosion on terminals, case or insidethe relay

    If the relay malfunctions or the operating val-ues differ from those specified, the relay shouldbe overhauled. Minor measures can be takenby the customer but any major repair involvingthe electronics has to be carried out by themanufacturer. Please contact the manufactureror his nearest representative for further infor-mation about checking, overhaul and recalibra-tion of the relay.

    The protection relay contains circuits that aresensitive to electrostatic discharge. If you haveto withdraw a relay module, ensure that you areat the same potential as the module, for instance,by touching the case.

    Note!Protection relays are measuring instruments andshould be handled with care and protectedagainst moisture and mechanical stress, espe-cially during transport.

    Spare parts Combined frequency and rate of change of frequency relay module SPCF 1D15Combined power supply and I/O module- U = 80...265 V ac/dc (operative range) SPTU 240R4- U = 18...80 V dc (operative range) SPTU 48R4Case (including connection module) SPTK 1E18Bus connection module SPA-ZC 17_

    SPA-ZC 21_

    Order numbers(modified 98-03)

    Frequency relay SPAF 140 C without test adapter: RS 452 001-AA, CA

    Frequency relay SPAF 140 C with test adapter RTXP 18: RS 452 201-AA, CA

    The letter combinations of the order number indicate the auxiliary voltage Uaux of the protectionrelay. The rated frequency is selected in the software.

    AA: Uaux = 80...265 V ac/dcCA: Uaux = 18...80 V dc

  • 8/3/2019 Fm Spaf140c en Cda

    13/56

    13

    Dimension

    drawings and

    mounting

    The basic model of the protection relay case isdesigned for flush-mounting. When required,raising frames can be used for reducing themounting depth of the case: type SPA-ZX 111reduces the depth by 40 mm, type SPA-ZX 112by 80 mm and type SPA-ZX 113 by 120 mm.

    A relay case type SPA-ZX 110 is available forsurface mounting.

    Fig. 12. Dimension and mounting drawings for frequency relay SPAF 140 C.

    The relay case is made of profile aluminium andpainted grey.

    The rubber gasket fitted to the mounting collarprovides an IP 54 degree of protection by en-closure between the relay case and the mount-ing base.

    The hinged cover of the case is made of trans-parent, UV-stabilized polycarbonate polymerand provided with two sealable locking screws.The rubber gasket of the cover provides an IP54 degree of protection between the case andthe cover.

    The required input and output circuits are con-nected to the screw terminals on the rear panel.

    Each terminal screw is dimensioned for one wireof maximum 6 mm2 or two wires of maximum2.5 mm2. Some of the control inputs are situ-ated in the detachable 6-pole connector.

    The 9-pole D-type connector is intended forserial communication.

    Raising frame

    SPA-ZX 111SPA-ZX 112SPA-ZX 113

    17613696

    74114154

    a b

    a b

    Panel cut-out

    129 1

    139

    1

    142

    162

    136

    30

    34

    250

    186

    216

    Ordering

    information

    Example1. Number and type designation 10 SPAF 140 C units2. Order number RS 454 001 -AA 3. Auxiliary voltage Uaux = 110 V dc

    4. Accessories 10 bus connection modules SPA-ZC 17 MM2A 6. Special requirements

  • 8/3/2019 Fm Spaf140c en Cda

    14/56

  • 8/3/2019 Fm Spaf140c en Cda

    15/56

    SPCF 1D15

    TRIP

    RESET

    STEP

    0024C

    PROGRAM

    IRFfU

    f

    df

    dt

    SGR

    SGB

    SGF

    [ ]nf

    U /

    (fn+fr)of an overcurrent relay module. The initial value

    a)Press push button STEP repeatedly until theLED close to the I> symbol is lit and the currentstart value appears on the display.

    b)Enter the submenu to get the main setting valueby pressing the PROGRAM push button morethan one second and then releasing it. The reddisplay digit now shows a flashing number 1,indicating the first submenu position and thegreen digits show the set value.

    c)Enter the setting mode by pressing the PRO-

    GRAM push button for five seconds until thedisplay starts flashing.

    d)Press the PROGRAM push button once againfor one second to get the rightmost digit flash-ing.

    e)

    Now the flashing digit can be altered. Use theSTEP push button to set the digit to the desiredvalue.

    f)Press the PROGRAM push button to make themiddle one of the green digits flash.

    g)Set the middle digit with of the STEP pushbutton.

    h)Press the PROGRAM push button to make theleftmost green digit flash.

    for the main setting is 0.80 x In and for thesecond setting 1.00 x In. The desired main startvalue is 1.05 x In.

    5 x 1 s

    1 s

    5 s

    1 s

    5 x

    1 s

    2 x

    1 s

    0. 8 0

    1 0. 8 0

    1 0. 8 0

    1 0. 8 0

    1 0. 8 5

    1 0. 8 5

    1 0. 0 5

    1 0. 0 5

    RESET

    STEP

    PROGRAM

    PROGRAM

    PROGRAM

    RESET

    STEP

    RESET

    STEP

    PROGRAM

    PROGRAM

  • 8/3/2019 Fm Spaf140c en Cda

    48/56

    8

    1 s

    0 x

    1 s

    0 x

    1 s

    5 s

    1 1. 0 5

    1 1. 0 5

    1 1. 0 5

    1 1. 0 5

    1 - - -

    1 1. 0 5

    2 1. 0 0

    i)Set the digit with the STEP push button.

    j)Press the PROGRAM push button to make thedecimal point flash.

    k)If needed, move the decimal point with theSTEP push button.

    l)Press the PROGRAM push button to make the

    whole display flash. In this position, corre-sponding to position c) above, one can see thenew value before it is recorded. If the valueneeds changing, use the PROGRAM push but-ton to alter the value.

    m)When the new value has been corrected, recordit in the memory of the relay module by pressingthe PROGRAM and STEP push buttons simul-taneously. At the moment the information en-

    ters the memory, the green dashes flash once inthe display, i.e. 1 - - -.

    n)Recording of the new value automatically initi-ates a return from the setting mode to thenormal submenu. Without recording one canleave the setting mode any time by pressing thePROGRAM push button for about five sec-onds, until the green display digits stop flashing.

    o)If the second setting is to be altered, entersubmenu position 2 of the setting I> by pressingthe STEP push button for approx. one second.The flashing position indicator 1 will then bereplaced by a flashing number 2 which indicatesthat the setting shown on the display is thesecond setting for I>.

    Enter the setting mode as in step c) and proceedin the same way. After recording of the re-quested values return to the main menu is

    obtained by pressing the STEP push button

    RESET

    STEP

    PROGRAM

    RESET

    STEP

    PROGRAM

    RESET

    STEP

    PROGRAM

    PROGRAM

    RESET

    STEP

    until the first digit is switched off. The LED stillshows that one is in the I> position and thedisplay shows the new setting value currently in

    use by the relay module.

  • 8/3/2019 Fm Spaf140c en Cda

    49/56

    9

    Example 2

    5 s

    1 x

    1 s

    1 x

    1 s

    Operation in the setting mode. Manual settingof the main setting of the checksum for theswitchgroup SGF1 of a relay module. The initialvalue for the checksum is 000 and the switches

    SGF1/1and SGF1/3 are to be set in position 1.This means that a checksum of 005 should bethe final result.

    n x 1 s

    1 s

    a)Press push button STEP until the LED close tothe SGF symbol is lit and the checksum appearson the display.

    b)Enter the submenu to get the main checksum ofSGF1 by pressing the PROGRAM push buttonfor more than one second and then releasing it.The red display now shows a flashing number 1indicating the first submenu position and thegreen digits show the checksum.

    c)Enter the setting mode by pressing the PRO-

    GRAM push button for five seconds until thedisplay starts flashing.

    d)Press the PROGRAM push button once againto get the first switch position. The first digit ofthe display now shows the switch number. Theposition of the switch is shown by the rightmostdigit.

    e)The switch position can now be toggled be-tween 1 and 0 by means of the STEP pushbutton and it is left in the requested position 1.

    f) When switch number 1 is in the requestedposition, switch number 2 is called up by press-ing the PROGRAM push button for one sec-ond. As in step e), the switch position can be

    altered by using the STEP push button. As thedesired setting for SGF1/2 is 0 the switch is leftin the 0 position.

    g)Switch SGF1/3 is called up as in step f) bypressing the PROGRAM push button for aboutone second.

    0 0 0

    1 0 0 0

    1 0 0 0

    1 1 0

    1 1 1

    1 2 0

    1 3 0

    RESET

    STEP

    PROGRAM

    PROGRAM

    PROGRAM

    RESET

    STEP

    PROGRAM

    PROGRAM

  • 8/3/2019 Fm Spaf140c en Cda

    50/56

    10

    1 x

    n x 1 s

    5 s

    5 x 1 s

    1 0 0 5

    1 - - -

    1 0 0 5

    0 0 5

    1 3 1h)The switch position is altered to the desiredposition 1 by pressing the STEP push buttononce.

    i)Using the same procedure the switches SGF 1/4...8 are called up and, according to the exam-ple, left in position 0.

    j)In the final setting mode position, correspond-ing to step c), the checksum based on the setswitch positions is shown.

    k)If the correct checksum has been obtained, it isrecorded in the memory by pressing the pushbuttons PROGRAM and STEP simultaneously. At the moment the information enters thememory, the green dashes flash in the display,i.e.1 - - -. If the checksum is incorrect, thesetting of the separate switches is repeated usingthe PROGRAM and STEP push buttons start-ing from step d).

    l)Recording the new value automatically initiatesa return from the setting mode to the normalmenu. Without recording one can leave thesetting mode any time by pressing the PRO-GRAM push button for about five seconds,until the green display digits stop flashing.

    m)After recording the desired values return to themain menu is obtained by pressing the STEPpush button until the first digit is turned off.

    The LED indicator SGF still shows that one isin the SGF position and that the display showsthe new checksum for SGF1 currently in use bythe relay module.

    RESET

    STEP

    PROGRAM

    RESET

    STEP

    PROGRAM

    PROGRAM

    RESET

    STEP

  • 8/3/2019 Fm Spaf140c en Cda

    51/56

    11

    Recorded

    information

    The parameter values measured at the momentwhen a fault occurs or at the trip instant arerecorded in the registers. The recorded data,except for some parameters, are set to zero bypressing the push buttons STEP and PRO-GRAM simultaneously. The data in normalregisters are erased if the auxiliary voltage supplyto the relay is interrupted, only the set values andcertain other essential parameters are maintainedin non-volatile registers during a voltage failure.

    The number of registers varies with differentrelay module types. The functions of the regis-ters are illustrated in the descriptions of thedifferent relay modules. Additionally, the sys-tem front panel of the relay contains a simplifiedlist of the data recorded by the various relaymodules of the protection relay.

    All D type relay modules are provided with twogeneral registers: register 0 and register A.

    Register 0 contains, in coded form, the informa-tion about e.g. external blocking signals, statusinformation and other signals. The codes areexplained in the manuals of the different relaymodules.

    Register A contains the address code of the relaymodul which is reqiured by the serial communi-cation system.

    Submenu 1 of register A contains the data trans-fer rate value, expressed in kilobaud, of the serial

    communication.

    Submenu 2 of register A contains a bus commu-nication monitor for the SPAbus. If the protec-tion relay, which contains the relay module, islinked to a system including a contol datacommunicatoe, for instance SRIO 1000M andthe data communication system is operating,the counter reading of the monitor will be zero.Otherwise the digits 1...255 are continuouslyscrolling in the monitor.

    Submenu 3 contains the password required forchanging the remote settings. The address code,the data transfer rate of the serial communica-tion and the password can be set manually or viathe serial communication bus. For manual set-ting see example 1.

    The default value is 001 for the address code, 9.6kilobaud for the data transfer rate and 001 forthe password.

    In order to secure the setting values, all settings

    are recorded in two separate memory bankswithin the non-volatile memory. Each bank iscomplete with its own checksum test to verifythe condition of the memory contents. If, forsome reason, the contents of one bank isdisturbed, all settings are taken from the otherbank and the contents from here is transferred tothe faulty memory region, all while the relay isin full operation condition. If both memorybanks are simultaneously damaged the relay willbe be set out of operation, and an alarm signalwill be given over the serial port and the IRF

    output relay

  • 8/3/2019 Fm Spaf140c en Cda

    52/56

    12

    Trip test function Register 0 also provides access to a trip testfunction, which allows the output signals of therelay module to be activated one by one. If theauxiliary relay module of the protection assem-bly is in place, the auxiliary relays then willoperate one by one during the testing.

    When pressing the PROGRAM push buttonfor about five seconds, the green digits to theright start flashing indicating that the relaymodule is in the test position. The indicators ofthe settings indicate by flashing which outputsignal can be activated. The required outputfunction is selected by pressing the PROGRAMpush button for about one second.

    The indicators of the setting quantities refer tothe following output signals:

    Setting I> Starting of stage I>Setting t> Tripping of stage I>Setting I>> Starting of stage I>>

    Setting t>> Tripping of stage I>>etc.No indication Self-supervision IRF

    The selected starting or tripping is activated bysimultaneous pressing of the push buttonsSTEP and PROGRAM. The signal remainsactivated as long as the two push butttons arepressed. The effect on the output relays dependson the configuration of the output relay matrixswitches.

    The self-supervision output is activated by press-ing the STEP push button 1 second when nosetting indicator is flashing. The IRF output isactivated in about 1 second after pressing of theSTEP push button.

    The signals are selected in the order illustrated inFig. 4.

    REGISTER 0I> START I> TRIP I START I TRIP Io> START Io> TRIP IoSTART Io TRIP

    PROGRAM

    5 sPROGRAM

    1 sPROGRAM

    1 sPROGRAM

    1 sPROGRAM

    1 sPROGRAM

    1 s

    PROGRAM

    1 s

    PROGRAM

    1 sPROGRAM

    1 s

    STEP &

    PROGRAM

    STEP &

    PROGRAM

    STEP &

    PROGRAM

    STEP &

    PROGRAMSTEP &

    PROGRAM

    STEP &

    PROGRAM

    STEP &

    PROGRAM

    STEP &

    PROGRAM

    It

    I>t>

    Io> to>Io

    to

    IRF

    STEP

    PROGRAM

    1 s

    Fig. 5.Sequence order for the selection of output signals in the Trip test mode

    If, for instance, the indicator of the setting t> isflashing, and the push buttons STEP and PRO-GRAM are being pressed, the trip signal fromthe low-set overcurrent stage is activated. Re-turn to the main menu is possible at any stage ofthe trip test sequence scheme, by pressing thePROGRAM push button for about five sec-onds.

    Note!The effect on the output relays then depends onthe configuration of the output relay matrixswitchgroups SGR 1...3.

  • 8/3/2019 Fm Spaf140c en Cda

    53/56

    13

    SGR

    SGB

    SGF

    SPCJ 4D29

    TRIP

    PROGRAM

    RESET

    STEP

    L 1 L 2 L 3 o IRF

    3 >I

    IIII

    > nI I/

    k

    s>t [ ]

    n>>I I/

    s>>[ ]t

    so >

    ko

    [ ]t

    no >I I/

    s>>ot [ ]

    n>>o I/I

    879B

    I

    Example 3

    n x 1 s

    0 0 0 0

    5 s

    0 0 0 0

    Trip test function. Forced activation of theoutputs.

    a)Step forward on the display to register 0.

    b)Press the PROGRAM push button for aboutfive seconds until the three green digits to theright.

    c)Hold down the STEP push button. After onesecond the red IRF indicator is lit and the IRFoutput is activated. When the step push buttonis released the IRF indicator is switched off andthe IRF output resets.

    d)Press the PROGRAM push button for onesecond and the indicator of the topmost settingstart flashing.

    e)If a start of the first stage is required, now pressthe push-buttons PROGRAM and STEP simul-taneously. The stage output will be activated andthe output relays will operate according to theactual programming of the relay output

    switchgroups SGR.

    0 0 0 0

    RESET

    STEP

    PROGRAM

    RESET

    STEP

    PROGRAM

    SGR

    SGB

    SGF

    SPCJ 4D29

    TRIP

    PROGRAM

    RESET

    STEP

    L 1 L 2 L 3 o IRF

    3 >I

    IIII

    > nI I/

    k

    s>t [ ]

    n>>I I/

    s>>[ ]t

    so >

    ko

    [ ]t

    no >I I/

    s>>ot [ ]

    n>>o I/I

    879B

    I

  • 8/3/2019 Fm Spaf140c en Cda

    54/56

    14

    SGR

    SGB

    SGF

    SPCJ 4D29

    TRIP

    PROGRAM

    RESET

    STEP

    L 1 L 2 L 3 o IRF

    3 >I

    IIII

    > nI I/

    k

    s>t [ ]

    n>>I I/

    s>>[ ]t

    so >

    ko

    [ ]t

    no >I I/

    s>>ot [ ]

    n>>o I/I

    8

    79B

    I

    SGR

    SGB

    SGF

    SPCJ 4D29

    TRIP

    PROGRAM

    RESET

    STEP

    L 1 L 2 L 3 o IRF

    3 >I

    IIII

    > nI I/

    k

    s>t [ ]

    n>>I I/

    s>>[ ]t

    so >

    ko

    [ ]t

    no >I I/

    s>>ot [ ]

    n>>o I/I

    879B

    I

    0 0 0 0

    0 0 0 0

    f)To proceed to the next position press the PRO-GRAM push button for about 1 second untilthe indicator of the second setting starts flash-ing.

    g)Press the push buttons PROGRAM and STEPsimultaneously to activate tripping of stage 1(e.g. the I> stage of the overcurrent moduleSPCJ 4D29). The output relays will operateaccording to the actual programming of therelay switchgroups SGR. If the main trip relayis operated the trip indicator of the measuringmodule is lit.

    h)The starting and tripping of the remainingstages are activated in the same way as the firststage above. The indicator of the correspondingsetting starts flashing to indicate that the con-

    cerned stage can be activated by pressing theSTEP and PROGRAM buttons simultaneously.For any forced stage operation, the outputrelays will respond according to the setting ofthe relay output switchgroups SGR. Any timea certain stage is selected that is not wanted tooperate, pressing the PROGRAM button oncemore will pass by this position and move to thenext one without carrying out any operation ofthe selected stage.

    It is possible to leave the trip test mode at anystep of the sequence scheme by pressing thePROGRAM push button for about five secondsuntil the three digits to the right stop flashing.

    PROGRAM

    1 s

    RESET

    STEP

    PROGRAM

  • 8/3/2019 Fm Spaf140c en Cda

    55/56

    15

    Operation

    indication

    Fault codes

    A relay module is provided with a multiple ofseparate operation stages, each with its ownoperation indicator shown on the display and acommon trip indicator on the lower part of thefront plate of the relay module.

    The starting of a relay stage is indicated with onenumber which changes to another number whenthe stage operates. The indicator remains glow-ing although the operation stage resets. The

    In addition to the protection functions the relaymodule is provided with a self-supervision sys-tem which continuously supervises the functionof the microprocessor, its program executionand the electronics.

    Shortly after the self-supervision system detectsa permanent fault in the relay module, the redIRF indicator on the front panel is lit . At thesame time the module puts forward a control

    signal to the output relay of the self-supervisionsystem of the protection relay.

    In most fault situations a fault code, indicatingthe nature of the fault, appears on the display of

    the module. The fault code, which consists of ared figure "1" and a three digit green codenumber, cannot be removed from the display byresetting. When a fault occurs, the fault codeshould be recorded and stated when service isordered. When in a fault mode, the normalrelay menus are operative, i.e. all setting valuesand measured values can be accessed althoughthe relay operation is inhibited. The serial com-munication is also operative making it possible

    to access the relay information also from aremote site. The internal relay fault code shownon the display remains active until the internalfault possibly disappears and can also be re-motely read out as variable V 169.

    indicator is reset by means of the RESET pushbutton of the relay module. An unreset opera-tion indicator does not affect the function of theprotection relay module.

    In certain cases the function of the operationindicators may deviate from the above princi-ples. This is described in detail in the descrip-tions of the separate modules.

  • 8/3/2019 Fm Spaf140c en Cda

    56/56

    1MRS750135-MUM

    EN

    ABB Oy