Erik's Ridge Perc Letter

15
10/28/2015 Craig C. Kazanjian Kaz Brothers, L.C. 14660 Rothgeb Drive, Suite 201 Rockville, MD 20850 Re: Erik’s Ridge Subdivision: 13505 Danielle Cir, Brandywine, MD 20613 (Lot 1) 13501 Danielle Cir, Brandywine, MD 20613 (Lot 2) 13400 Danielle Cir, Brandywine, MD 20613 (Lot 6) 13301 Alyssa Ct, Brandywine, MD 20613 (Lot 16) Dear Mr. Kazanjian, In response to your request, a review has been conducted of the above referenced properties. The information gathered was taken from percolation test reports as well as from the site plan used in the approval of the subdivision “record linen.” Copies of the percolation test reports for the lots in question are enclosed. The reports can be used to design the septic systems as per the “Prince George’s County Septic System Design Manual.” The following is trench length requirements for residential living capacities of 4 and 5 bedroom houses on these properties. Also provided within the listing below is the “BAT” unit capacity required for a 4 and 5 bedroom home. Lot: Number of Bedrooms: Trench Length Requirement: BAT Capacity: 1 4 130 ft. (min. deep trench design) 600 gpd 1 5 142 ft. (min. deep trench design) 1000 gpd 2 4 150 ft. (min. deep trench design) 600gpd 2 5 212.5 (ft.) (min. deep trench design) 1000gpd 6 4 130 ft. (min. deep trench design) 600gpd 6 5 130 ft. (min deep trench design) 1000gpd 16 4 130 ft. (min. deep trench design) 600gpd 16 5 130 ft. (min deep trench design) 1000gpd *(Please note “15002000 gallon pump chambers” may be required in addition to the items listed above. If you have any questions, please contact me at (301)8837634. Sincerely, Jerod Briscoe, LEHS Health Review Section 9400 Peppercorn Place, 2nd Floor, Largo, MD 20774 Office 3018837621, Fax 3018833852, TTY/STS Dial 711

Transcript of Erik's Ridge Perc Letter

 

 

10/28/2015 

Craig C. Kazanjian                          

Kaz Brothers, L.C.                                              

14660 Rothgeb Drive, Suite 201                                                                                  

Rockville, MD 20850                                                             

Re:  Erik’s Ridge Subdivision: 

 

13505 Danielle Cir, Brandywine, MD 20613 (Lot 1) 

13501 Danielle Cir, Brandywine, MD 20613 (Lot 2) 

13400 Danielle Cir, Brandywine, MD 20613 (Lot 6) 

13301 Alyssa Ct, Brandywine, MD 20613 (Lot 16) 

 

Dear Mr. Kazanjian, In response to your request, a review has been conducted of the above referenced properties.  The information gathered was taken from 

percolation test reports as well as from the site plan used in the approval of the subdivision “record linen.”  Copies of the percolation test 

reports for the lots in question are enclosed.  The reports can be used to design the septic systems as per the “Prince George’s County 

Septic System Design Manual.” 

 

The following is trench length requirements for residential living capacities of 4 and 5 bedroom houses on these properties.  Also provided within the listing below is the “BAT” unit capacity required for a 4 and 5 bedroom home.  Lot:                                Number of Bedrooms:                                  Trench Length Requirement:                                         BAT Capacity: 

1                                                          4                                                          130 ft. (min. deep trench design)                              600 gpd 

1                                                          5                                                          142 ft. (min. deep trench design)                              1000 gpd 

 

2                                                          4                                                          150 ft. (min. deep trench design)                              600gpd 

2                                                          5                                                          212.5 (ft.) (min. deep trench design)                        1000gpd 

 

6                                                          4                                                          130 ft. (min. deep trench design)                              600gpd 

6                                                          5                                                          130 ft. (min deep trench design)                               1000gpd 

 

16                                                       4                                                          130 ft. (min. deep trench design)                               600gpd 

16                                                       5                                                          130 ft. (min deep trench design)                                1000gpd  

 

 

*(Please note “1500‐2000 gallon pump chambers” may be required in addition to the items listed above.  If you have any questions, please 

contact me at (301)‐883‐7634. 

 

Sincerely,  

 

 

Jerod Briscoe, LEHS 

Health Review Section 

9400 Peppercorn Place, 2nd Floor, Largo, MD 20774 

Office 301‐883‐7621, Fax 301‐883‐3852, TTY/STS Dial 711