10/28/2015
Craig C. Kazanjian
Kaz Brothers, L.C.
14660 Rothgeb Drive, Suite 201
Rockville, MD 20850
Re: Erik’s Ridge Subdivision:
13505 Danielle Cir, Brandywine, MD 20613 (Lot 1)
13501 Danielle Cir, Brandywine, MD 20613 (Lot 2)
13400 Danielle Cir, Brandywine, MD 20613 (Lot 6)
13301 Alyssa Ct, Brandywine, MD 20613 (Lot 16)
Dear Mr. Kazanjian, In response to your request, a review has been conducted of the above referenced properties. The information gathered was taken from
percolation test reports as well as from the site plan used in the approval of the subdivision “record linen.” Copies of the percolation test
reports for the lots in question are enclosed. The reports can be used to design the septic systems as per the “Prince George’s County
Septic System Design Manual.”
The following is trench length requirements for residential living capacities of 4 and 5 bedroom houses on these properties. Also provided within the listing below is the “BAT” unit capacity required for a 4 and 5 bedroom home. Lot: Number of Bedrooms: Trench Length Requirement: BAT Capacity:
1 4 130 ft. (min. deep trench design) 600 gpd
1 5 142 ft. (min. deep trench design) 1000 gpd
2 4 150 ft. (min. deep trench design) 600gpd
2 5 212.5 (ft.) (min. deep trench design) 1000gpd
6 4 130 ft. (min. deep trench design) 600gpd
6 5 130 ft. (min deep trench design) 1000gpd
16 4 130 ft. (min. deep trench design) 600gpd
16 5 130 ft. (min deep trench design) 1000gpd
*(Please note “1500‐2000 gallon pump chambers” may be required in addition to the items listed above. If you have any questions, please
contact me at (301)‐883‐7634.