Catalogo BC35

download Catalogo BC35

of 16

Transcript of Catalogo BC35

  • 7/28/2019 Catalogo BC35

    1/16

    BC35EDO

  • 7/28/2019 Catalogo BC35

    2/16

    BC35

    www.blbhydraulic.com2

    LENGTH

    PRESSURE

    VACUUM

    FLOW

    FORCE

    MASS

    TIME

    VOLUME

    TEMPERATURE

    TORQUE

    POWER

    SHAFT SPEED

    FREQUENCY

    DISPLACEMENT

    VELOCITY

    1 inch = 25.4 millimetre (mm)

    1 pound per square inch (PSI) = 0.069 bar (gage)

    1 inch of mercury (in Hg) = 0.034 bar (a value less

    than 1.0 at 60 degrees Fahrenheit 1(F)

    1 gallon per minute (GPM) = 3.785 litres per minute

    (l/min)

    1 gallon per minute (GPM) = 3785 cubic

    centimetres per minute (cc/min)

    1 poundf(Ibf) = 4.44 Newton (N)

    1 poundm (Ibm) = 0.455 kilogram (Kg)

    second (s)

    1 US gallon (gal) = 3.785 litre (l)

    1 US gallon (gal) = 3785 cubic centimetres (cc)

    F = (1.8 C) + 32

    1 poundfinch (Ibf - in.) = 0.1136 Newton metre (N

    m) or joule

    1 horsepower (HP) = 0.746 kilowatt (kW)

    revolutions per minute (RPM)

    1 cycle per second (cps) = 1 Hertz (Hz)

    1 cubic inch per revolution (cu. in./rev.) = 16.4

    cubic centimetres per revolution (cc/rev)

    1 foot per second (fps) = 0.305 metre per second

    (m/s)

    1 millimetre (mm) = 0.0394 inch

    1 bar (gage) = 14.493 pounds per square inch (PSI)

    0.1 bar (a value less than 1.0) = 2.94 inches of

    mercury (in Hg) at 15.6 degrees Celsius (C)

    1 litre per minute (l/min) = 0.264 gallons per minute

    (GPM)

    1 cubic centimetre per minute (cc/min) = 0.000264

    gallons per minute (GPM)

    1 Newton (N) = 0.225 poundf(Ibf)

    1 kilogram (kg) = 2.20 poundm (Ibm)

    second (s)

    1 litre (l) = 0.264 US gallon (gal)

    1 cubic centimetre (cc) = 0.000264 US gallons (gal)

    C = 0.556 (F - 32)

    1 Newton metre (N m) or joule = 8.8 poundfinches

    (Ibf - in.)

    1 kilowatt (kW) = 1.34 horsepower (HP)

    revolutions per minute (rev/min)

    1 Hertz (Hz) = 1 cycle per second (cps)

    1 cubic centimetre per revolution (cc/rev) = 0.061

    cubic inches per revolution (cu. in./rev.)

    1 metre per second (m/s) = 3.28 feet per second (fps)

    NOTE: 1 cubic (cc) = 1 millilitre (ml) = 0.001 litre (l)

    UNIT CONVERSION TABLE

  • 7/28/2019 Catalogo BC35

    3/16www.blbhydraulic.com 3

    GENERAL INDICATIONS

    TECHNICAL CHARACTERISTICS

    DESIGNATION SAMPLE

    TE INLETS

    S EDO - V EDO STANDARD ELEMENTS

    CF EDO - CFV EDO FLOW CONTROL ELEMENTS

    RFS - RFSO FLOW CONTROL SECTIONS

    RFP - RFPO FLOW CONTROL SECTIONS

    P EDO - PV EDO PRIORITY ELEMENTS

    R EDO - RV EDO RECUPERATION ELEMENTS

    TU OUTLETS

    ELECTRIC JOYSTICKS

    ACCESSORIES

    INDEX BC35

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

  • 7/28/2019 Catalogo BC35

    4/16www.blbhydraulic.com4

    This booklet is meant to be a technical deepening on the BC35 directional control valve. Choice, use, maintenance and warrantyconditions of all BLB products are described in the BLB General Catalogue.

    The BC35 sectional valve has been designed for the remote electric actuation of systems with x displacement pumps.

    However, the installation of an auxiliary electro-valve (LSK) allows the utilization of the BC35 valve in systems with variable displa-

    cement pumps (LS).

    GENERAL INDICATIONSBC35

    12345678

    76

    140

    110 31

    120

    A

    B

    A

    B

    A

    B

    TP

    45 35 4635

    I

    83

    130

    125

    161L

    279

    Without relief valve Open center Close center

    High pressure carry over (power beyond)

    COT2 CCP

    VLA

    VLB

    RVP

    RVP

    VLRVP

    T T

    PP

    P2 P2

    T T T

    141

  • 7/28/2019 Catalogo BC35

    5/16www.blbhydraulic.com 5

    BC35TECHNICAL CHARACTERISTICS

    4-WAY / 3-POSITION SPOOL. Provides control of double-acting cylinders or bi-directional

    hydraulic motors. In position 0 work ports are blocked.

    3-WAY / 3-POSITION SPOOL. Provides control of single-acting cylinders or start and stop

    of uni-directional hydraulic motors. In position 0 work port is blocked. B port is plugged.

    4-WAY / 3-POSITION SPOOL, OPEN CENTER (MOTOR SPOOL). Provides control of dou-

    ble acting cylinders or bi-directional hydraulic motors. Allows a cylinder to oat or a motor

    to wheel free when the spool is in position 0. Work ports are open to the tank port when the

    spool is in position 0.

    DE

    BE

    AE

    SPOOL TYPES

    0 5

    (1,3)

    20

    (5,2)

    30

    (7,9)

    (PSI) bar

    (218) 15

    (145) 10

    (73) 5

    P T

    1

    P T

    10

    (2,6)

    15

    (3,9)

    25

    (6,5)

    2

    3

    5

    4

    6

    NOMINAL FLOW

    MAX FLOW

    NOMINAL PRESSURE

    MAX PRESSURE ON PORTS

    MAX PRESSURE ON TANK-LINE

    30 l/min

    35 l/min

    200 bar

    250 bar

    15 bar

    8 GPM

    9,2 GPM

    2900 PSI

    3600 PSI

    220 PSI

    TECHNICAL CHARACTERISTICS

    From A B to T

    Pressure

    Oil temperature

    Oil viscosity

    4 8 cc/min

    100 bar

    40 C

    32 mm/s

    INTERNAL OIL LEAKAGE

    TESTING CONDITIONS

    G (BSP)

    F (UNF)

    A - B

    3/8

    3/4-16

    P

    3/8

    3/4-16

    T

    3/8

    3/4-16

    P2

    3/8

    3/4-16

    T2

    3/8

    3/4-16

    STANDARD THREADSBC35/1

    BC35/2

    BC35/3

    BC35/4

    ...

    NUMBEROF SECTIONS

    91

    126

    161

    196

    ...

    (mm)

    55

    90

    125

    160

    ...

    3,58

    4,96

    6,33

    7,71

    ...

    2,16

    3,54

    4,92

    6,29

    ...

    L

    (inch) (mm) (inch)

    I

    ACTUATORS

    MO...EDOCombined push-pull and manual actuator

    PP A/B

    0 5

    (1,3)

    20

    (5,2)

    30

    (7,9)

    (PSI) bar

    (218) 15

    (145) 10

    (73) 5

    1

    10

    (2,6)

    15

    (3,9)

    25

    (6,5)

    23

    54

    6(290) 20

    TA/B

    numberofworkingsections

    l/min

    (GPM)

    T

    0 5

    (1,3)

    20

    (5,2)

    30

    (7,9)

    (PSI) bar

    (218) 15

    (145) 10

    (73) 5

    1

    10

    (2,6)

    15

    (3,9)

    25

    (6,5)

    2

    3

    54

    6

    The BC35 sectional valve has the following features:

    Possibility to have auxiliary valves on ports

    Check valves on each section; Priority ow control sections (RFS, RFP);

    Elements with integrated pressure compensated ow control (CF, CFV).

    Thanks to its high versatility and modular structure, the BC35 valve can be used in simple and complex hydraulic systems, fullling

    the most advanced requirements of the modern mobile machines.

  • 7/28/2019 Catalogo BC35

    6/16www.blbhydraulic.com6

    DESIGNATION SAMPLEBC35

    TYPE

    OF VALVE

    NUMBER

    OF ELEMENTS

    VOLTAGE

    12 volt DC

    24 volt DC

    OUTLET OPTIONS

    CO Carry over

    CCP Close center plug

    TYPE OF ELEMENT

    S Standard element

    VElement accepting valves on ports

    P Priority element

    PVPriority element accepting valves on portsR Recuperation element

    RVRecuperation element accepting valves on ports

    CF Element with compensated priority ow control

    CFV Element with compensated priority ow control

    accepting valves on ports

    TYPE OF ACTUATOR

    EDO Push-pull electric actuator

    SPOOL TYPE

    AE Double acting

    BE Single acting

    DE Motor spoolTYPE OF INLET RELIEF VALVE

    U 90250 bar

    K150300 bar

    TYPE OF ELEMENT

    S Standard element

    VElement accepting valves on ports

    P Priority element

    PVPriority element accepting valves on portsR Recuperation element

    RVRecuperation element accepting valves on ports

    CF Element with compensated priority ow control

    CFV Element with compensated priority ow control

    accepting valves on ports

    TYPE OF ACTUATOR

    EDO Push-pull

    electric actuator

    SPOOL TYPE

    AE Double actingBE Single acting

    DE Motor spool

    AUXILIARY VALVES ON PORTS

    VL Main relief valve

    VC Anticavitation

    VLC Combined anticavitation

    - Antishock valve

    PRIORITY FLOW

    CONTROL SECTION

    RFS Exceeding ow

    to the tank

    RFP Exceeding ow

    recuperated

    INLET TYPE

    DVDump valve

    RFPE DVproportionally

    controlled ow regulator

    RVP Relief valve plug

    TYPE OF THREADS

    G British standard parallel

    F American standard UNF

    APort

    B Port

    P Pump connection

    P2 Pump connection

    RVP Relief valve plug

    DVDump valve

    DVP Dump valve plug

    EDO Push-pull electric actuator

    MO Manual actuator

    VL Main relief valve

    VLABAntishock valves

    VLC Antishock and anticavitation valve

    VC Anticavitation valve

    T Tank connection

    T2 Tank connection

    CCP Close center plug

    CO Carry over

    MANDATORY FIELD

    OPTIONAL FIELD

    LEGEND

    T

    T

    VLA

    VLB

    P

    P2

    T

    VL

    BC35/3 12 DV GK /S MO AE EDO/RFS/V MO AE EDO VLAB/CO

    TYPE OF

    ACTUATOR

    MO Manual

    actuator

    TYPE OF

    ACTUATOR

    MO Manual

    actuator

  • 7/28/2019 Catalogo BC35

    7/16www.blbhydraulic.com 7

    BC35TE RFPE DV GU 12

    BC35TE RFPE DV GU 24

    BC35TE RFPE DV GK 12

    BC35TE RFPE DV GK 24

    BC35TE RFEP DV FU 12

    BC35TE RFEP DV FU 24

    BC35TE RFEP DV FK 12

    BC35TE RFEP DV FK 24

    805135

    805193

    805194

    805195

    805196

    805197

    805198

    805199

    TE INLETS BC35

    BC35TE DV GU12

    BC35TE DV GU24

    BC35TE DV GK12BC35TE DV GK24

    BC35TE DV FU12

    BC35TE DV FU24

    BC35TE DV FK12

    BC35TE DV FK24

    805186

    805139

    805187805188

    805189

    805190

    805191

    805192

    TE DV

    2,5 kg

    P

    P2

    T

    VL

    TE RFPE DV

    3,1 kg

    BC35TE GU

    BC35TE GK

    BC35TE FU

    BC35TE FK

    805027

    805057

    805024

    805032

    TE

    0,9 kg

    P

    P2

    T

    VL

    DV dump valve prevents the unwanted or accidental use of the directional control valve, con-

    necting the pump ow to the tank.

    The BC35TE RFPE DV inlet features a dump valve that prevents the unwanted or accidental use of the directional control valve,

    connecting the pump ow to the tank.

    It also features a logic valve (ELP/30) and a proportionally controlled ow regulator (PSS/30).The combination of these two elements allows the proportional regulation of the ow going to following elements, connecting to the

    tank the exceeding ow not needed.

    ELP/30

    P

    P2

    T

    VL

    PSS/30

  • 7/28/2019 Catalogo BC35

    8/16www.blbhydraulic.com8

    BC35

    STANDARD ELEMENT STANDARD ELEMENT

    ACCEPTING

    VALVES

    ON PORTS

    BC35S 12 G /MO AE EDO/

    BC35S 24 G /MO AE EDO/

    BC35S 12 F /MO AE EDO/

    BC35S 24 F /MO AE EDO/

    807638

    807640

    807650

    807888

    BC35V 12 G /MO AE EDO RVPAB/

    BC35V 24 G /MO AE EDO RVPAB/

    BC35V 12 F /MO AE EDO RVPAB/

    BC35V 24 F /MO AE EDO RVPAB/

    807644

    807897

    807898

    807899

    BC35S 12 G /MO BE EDO/

    BC35S 24 G /MO BE EDO/

    BC35S 12 F /MO BE EDO/BC35S 24 F /MO BE EDO/

    807889

    807890

    807891807892

    BC35V 12 G /MO BE EDO RVPAB/

    BC35V 24 G /MO BE EDO RVPAB/

    BC35V 12 F /MO BE EDO RVPAB/

    BC35V 24 F /MO BE EDO RVPAB/

    807904

    807905

    807906807907

    BC35S 12 G /MO DE EDO/

    BC35S 24 G /MO DE EDO/

    BC35S 12 F /MO DE EDO/

    BC35S 24 F /MO DE EDO/

    807893

    807894

    807895

    807896

    BC35V 12 G /MO DE EDO RVPAB/

    BC35V 24 G /MO DE EDO RVPAB/

    BC35V 12 F /MO DE EDO RVPAB/

    BC35V 24 F /MO DE EDO RVPAB/

    807912

    807913

    807914

    807915

    BC35V 12 G /MO AE EDO VLAB/

    BC35V 24 G /MO AE EDO VLAB/

    BC35V 12 F /MO AE EDO VLAB/

    BC35V 24 F /MO AE EDO VLAB/

    807900

    807901

    807902

    807903

    BC35V 12 G /MO BE EDO VLAB/

    BC35V 24 G /MO BE EDO VLAB/

    BC35V 12 F /MO BE EDO VLAB/

    BC35V 24 F /MO BE EDO VLAB/

    807908

    807909

    807910

    807911

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    BC35V 12 G /MO DE EDO VLAB/

    BC35V 24 G /MO DE EDO VLAB/

    BC35V 12 F /MO DE EDO VLAB/

    BC35V 24 F /MO DE EDO VLAB/

    807916

    807917

    807918

    807919

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    Double acting Double acting

    Single acting Single acting

    Motor spool Motor spool

    S EDO - V EDO STANDARD ELEMENTS

    S V2,2 kg 2,7 kg

    P

    0

    2

    1

    B

    A

    A

    P

    0

    2

    1

    B

    A

    A

    RVP

    RVP

    P

    0

    2

    1

    B

    A

    B A

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

    B

    P

    0

    2

    1

    B

    A

    A

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

  • 7/28/2019 Catalogo BC35

    9/16www.blbhydraulic.com 9

    CF EDO - CFV EDO FLOW CONTROL ELEMENTS

    BC35CF 12 G /MO AE EDO/

    BC35CF 24 G /MO AE EDO/

    BC35CF 12 F /MO AE EDO/

    BC35CF 24 F /MO AE EDO/

    807920

    807921

    807922

    807923

    BC35CFV 12 G /MO AE EDO RVPAB/

    BC35CFV 24 G /MO AE EDO RVPAB/

    BC35CFV 12 F /MO AE EDO RVPAB/

    BC35CFV 24 F /MO AE EDO RVPAB/

    BC35CFV 12 G /MO AE EDO VLAB/

    BC35CFV 24 G /MO AE EDO VLAB/

    BC35CFV 12 F /MO AE EDO VLAB/

    BC35CFV 24 F /MO AE EDO VLAB/

    807932

    807933

    807934

    807935

    807936

    807937

    807938

    807939

    BC35CF 12 G /MO BE EDO/

    BC35CF 24 G /MO BE EDO/

    BC35CF 12 F /MO BE EDO/

    BC35CF 24 F /MO BE EDO/

    807924

    807925

    807926

    807927

    BC35CF 12 G /MO DE EDO/

    BC35CF 24 G /MO DE EDO/

    BC35CF 12 F /MO DE EDO/

    BC35CF 24 F /MO DE EDO/

    807928

    807929

    807930

    807931

    BC35CFV 12 G /MO BE EDO RVPAB/

    BC35CFV 24 G /MO BE EDO RVPAB/

    BC35CFV 12 F /MO BE EDO RVPAB/

    BC35CFV 24 F /MO BE EDO RVPAB/

    BC35CFV 12 G /MO BE EDO VLAB/

    BC35CFV 24 G /MO BE EDO VLAB/

    BC35CFV 12 F /MO BE EDO VLAB/

    BC35CFV 24 F /MO BE EDO VLAB/

    807940

    807941

    807942

    807943

    807944

    807945

    807946

    807947

    BC35CFV 12 G /MO DE EDO RVPAB/

    BC35CFV 24 G /MO DE EDO RVPAB/

    BC35CFV 12 F /MO DE EDO RVPAB/

    BC35CFV 24 F /MO DE EDO RVPAB/

    BC35CFV 12 G /MO DE EDO VLAB/

    BC35CFV 24 G /MO DE EDO VLAB/

    BC35CFV 12 F /MO DE EDO VLAB/

    BC35CFV 24 F /MO DE EDO VLAB/

    807948

    807949

    807950

    807951

    807952

    807953

    807954

    807955

    CF

    FLOW CONTROL

    ELEMENT

    ACCEPTING

    VALVES

    ON PORTS

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.NOTE: After a CF or CFV the

    frst element must be a R type

    CFV

    Double acting

    Single acting

    Motor spool Motor spool

    Single acting

    Double acting

    FLOW CONTROL ELEMENT

    CF and CFV elements integrate

    a pressure compensated ow

    control that allows the external

    regulation of the ow inside theelements themselves and recu-

    perates the exceeding ow (EF)

    for the following elements.

    2,6 kg 3,2 kg

    P0

    2

    1

    B

    A

    B A B A

    P

    0

    2

    1

    B

    A

    RVP

    RVP

    A

    P

    0

    2

    1

    A

    RVP

    RVP

    P

    0

    2

    1

    A

    A

    B A

    P

    0

    2

    1

    B

    A

    RVP

    RVP

    P

    0

    2

    1

    B

    A

    B A

    BC35

  • 7/28/2019 Catalogo BC35

    10/16www.blbhydraulic.com10

    The pressure compensated ow control section RFS, divides the

    ow in two channels: the priority ow (PF) channel, adjustable

    with the external knob, and the exceeding ow (EF) channel that

    goes to tank. Elements preceding RFS sections receive the fullpump ow whereas the elements following RFS sections receive

    just the ow requested and settled. In order to prevent undesired

    heating in the system, the RFS section works only when one ormore of the following sections are operated. The RFS section

    can be combined with all standard elements.

    BC35 RFS

    BC35 RFSO

    835078

    835081

    HORIZONTALVERTICAL

    EXAMPLE The motor (A) is fed by the whole ow of the pump. The cylinders (C, D) downstream the ow control element (RFS) are fed only by the priority ow (PF)

    which is adjustable through the ow control knob on the element. The excess ow goes to tank.

    RFS - RFSO FLOW CONTROL SECTIONSBC35

    1,2 kg1,2 kg

    T2

    T

    T

    VL

    P2

    P

    TE S RFS S S TU

    Priority ow

    Excessfow

  • 7/28/2019 Catalogo BC35

    11/16www.blbhydraulic.com 11

    RFP - RFPO FLOW CONTROL SECTIONS BC35

    BC35 RFP

    BC35 RFPO

    835079

    835122

    The pressure compensated ow control section RFP, divides

    the ow in two channels: the rst channel receives the priority

    ow (PF) (adjustable with the external knob) and feeds one or

    more Priority elements (P, PV); the second channel receives

    the exceeding ow (EF) and feeds one ore more Recuperationelements (R, RV) which follow the priority ones. RFP sections,

    have to be followed by one or more priority elements (P, PV);Priority elements have to be followed by one or more Recupe-

    ration elements (R, RV). In order to prevent undesired heating

    in the system the RFP section works only when one or more of

    the Priority sections are operated. The installation of an RFPsection, allows the contemporaneous operation of one Priority

    element and one Recuperation element which will work at diffe-

    rent ows and pressures without interfering one with the other.

    When no Priority section is operated, the Recuperation elements

    get the full pump ow.

    HORIZONTALVERTICAL

    EXAMPLEThe motors (A, B) are fed by the priority ow (PF) which is adjustable through the ow control knob on the element. The cylinders (C, D) are fed by the whole owof the pump when singly actuated. When a cylinder and a motor are simultaneously actuated, the motor is fed by the priority ow (PF) and the cylinder by the exceeding ow

    (EF). If a cylinder is actuated while a motor is in work, this last will not vary its rotation speed.

    1,2 kg1,2 kg

    TE RFP P

    T

    T

    T

    VL

    P2

    P

    P R S TU

    Priority ow

    Excess ow

  • 7/28/2019 Catalogo BC35

    12/16www.blbhydraulic.com12

    BC35PV 12 G /MO BE EDO RVPAB/

    BC35PV 24 G /MO BE EDO RVPAB/

    BC35PV 12 F /MO BE EDO RVPAB/BC35PV 24 F /MO BE EDO RVPAB/

    807976

    807977

    807978807979

    BC35PV 12 G /MO DE EDO RVPAB/

    BC35PV 24 G /MO DE EDO RVPAB/

    BC35PV 12 F /MO DE EDO RVPAB/

    BC35PV 24 F /MO DE EDO RVPAB/

    807984

    807985

    807986

    807987

    BC35P 12 G /MO AE EDO/

    BC35P 24 G /MO AE EDO/

    BC35P 12 F /MO AE EDO/

    BC35P 24 F /MO AE EDO/

    807956

    807957

    807958

    807959

    BC35P 12 G /MO BE EDO/

    BC35P 24 G /MO BE EDO/

    BC35P 12 F /MO BE EDO/BC35P 24 F /MO BE EDO/

    807960

    807961

    807962807963

    BC35P 12 G /MO DE EDO/

    BC35P 24 G /MO DE EDO/

    BC35P 12 F /MO DE EDO/

    BC35P 24 F /MO DE EDO/

    807964

    807965

    807966

    807967

    807968

    807969

    807970

    807971

    BC35PV 12 G /MO AE EDO RVPAB/

    BC35PV 24 G /MO AE EDO RVPAB/

    BC35PV 12 F /MO AE EDO RVPAB/

    BC35PV 24 F /MO AE EDO RVPAB/

    PRIORITY ELEMENT PRIORITY

    ELEMENT

    ACCEPTING

    VALVES ON

    PORTS

    807972

    807973

    807974

    807975

    BC35PV 12 G /MO AE EDO VLAB/

    BC35PV 24 G /MO AE EDO VLAB/

    BC35PV 12 F /MO AE EDO VLAB/

    BC35PV 24 F /MO AE EDO VLAB/

    807980

    807981

    807982

    807983

    BC35PV 12 G /MO BE EDO VLAB/

    BC35PV 24 G /MO BE EDO VLAB/

    BC35PV 12 F /MO BE EDO VLAB/

    BC35PV 24 F /MO BE EDO VLAB/

    807988

    807989

    807990

    807991

    BC35PV 12 G /MO DE EDO VLAB/

    BC35PV 24 G /MO DE EDO VLAB/

    BC35PV 12 F /MO DE EDO VLAB/

    BC35PV 24 F /MO DE EDO VLAB/

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    Double acting

    Single acting

    Motor spool

    Double acting

    Single acting

    Motor spool

    P PV

    P EDO - PV EDO PRIORITY ELEMENTSBC35

    P elements use the priority ow regulated by

    the RFP sections. They have to be installed

    after an RFP section.

    2,2 kg 2,7 kg

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

    P

    0

    2

    1

    B

    A

    A

    RVP

    RVP

    P

    0

    2

    1

    B

    A

    A

    B

    P

    0

    2

    1

    B

    A

    A

    P

    0

    2

    1

    B

    A

    B A

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

  • 7/28/2019 Catalogo BC35

    13/16www.blbhydraulic.com 13

    R EDO - RV EDO RECUPERATION ELEMENTS BC35

    BC35R 12 G /MO AE EDO/

    BC35R 24 G /MO AE EDO/

    BC35R 12 F /MO AE EDO/

    BC35R 24 F /MO AE EDO/

    807992

    807993

    807994

    807995

    BC35R 12 G /MO BE EDO/

    BC35R 24 G /MO BE EDO/

    BC35R 12 F /MO BE EDO/BC35R 24 F /MO BE EDO/

    807996

    807997

    807998807999

    BC35R 12 G /MO DE EDO/

    BC35R 24 G /MO DE EDO/

    BC35R 12 F /MO DE EDO/

    BC35R 24 F /MO DE EDO/

    808001

    808002

    808003

    808004

    BC35RV 12 G /MO DE EDO RVPAB/

    BC35RV 24 G /MO DE EDO RVPAB/

    BC35RV 12 F /MO DE EDO RVPAB/

    BC35RV 24 F /MO DE EDO RVPAB/

    808021

    808022

    808023

    808024

    BC35RV 12 G /MO BE EDO RVPAB/

    BC35RV 24 G /MO BE EDO RVPAB/

    BC35RV 12 F /MO BE EDO RVPAB/BC35RV 24 F /MO BE EDO RVPAB/

    808013

    808014

    808015808016

    BC35RV 12 G /MO AE EDO RVPAB/

    BC35RV 24 G /MO AE EDO RVPAB/

    BC35RV 12 F /MO AE EDO RVPAB/

    BC35RV 24 F /MO AE EDO RVPAB/

    808005

    808006

    808007

    808008

    BC35RV 12 G /MO AE EDO VLAB/

    BC35RV 24 G /MO AE EDO VLAB/

    BC35RV 12 F /MO AE EDO VLAB/

    BC35RV 24 F /MO AE EDO VLAB/

    808009

    808010

    808011

    808012

    BC35RV 12 G /MO BE EDO VLAB/

    BC35RV 24 G /MO BE EDO VLAB/

    BC35RV 12 F /MO BE EDO VLAB/

    BC35RV 24 F /MO BE EDO VLAB/

    808017

    808018

    808019

    808020

    BC35RV 12 G /MO DE EDO VLAB/

    BC35RV 24 G /MO DE EDO VLAB/

    BC35RV 12 F /MO DE EDO VLAB/

    BC35RV 24 F /MO DE EDO VLAB/

    808025

    808026

    808027

    808028

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    VL valves on ports A and B are type U.

    Standard setting 140 bar.

    Double acting

    Single acting

    Motor spool

    Double acting

    Single acting

    Motor spool

    RECUPERATION ELEMENT RECUPERATION

    ELEMENT

    ACCEPTING

    VALVES ON

    PORTS

    R RV

    R elements use the exceeding ow coming

    from an RFP section. They have to be in-

    stalled only after one or more P elements.

    2,2 kg 2,7 kg

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

    B

    P

    0

    2

    1

    B

    A

    A

    P

    0

    2

    1

    B

    A

    A

    P

    0

    2

    1

    B

    A

    A

    RVP

    RVP

    P

    0

    2

    1

    B

    A

    B A

    P

    0

    2

    1

    B

    A

    B A

    RVP

    RVP

  • 7/28/2019 Catalogo BC35

    14/16www.blbhydraulic.com14

    TU OUTLETSBC35

    TU

    TU

    OUTLET

    OUTLET

    0,8 kg

    1,9 kg

    T

    T

    TB

    P

    0

    2

    1

    B

    A

    A

    T

    T

    BC35TU 12 KEO G

    BC35TU 24 KEO G

    BC35TU 12 KEO F

    BC35TU 24 KEO F

    805134

    805184

    805185

    805186

    BC35TU G

    BC35TU F

    805028

    805025

    BC35TE KEO outlet features an electric 3 ways valve. Connected to a special element, thisvalve, when operated, connects A and B ports to tank, allowing a cylinder or a motor to oat.

  • 7/28/2019 Catalogo BC35

    15/16www.blbhydraulic.com 15

    ELECTRIC JOYSTICKS

    ELECTRIC JOYSTICKS

    POWER CONNECTOR

    CONNECTION WIRES

    JME 2S

    JME 4S

    JME 6S

    JME 8S

    JME 10S

    023065

    023066

    023067

    023068

    023069

    JSE 2S

    JSE 4S

    JSE 6S

    JSE 8S

    JSE 10S

    023062

    023063

    023061

    023060

    023064

    VC CONNECTOR

    ELECTRIC JOYSTICK WITH 1 AXIS AND MICROSWITCHES1 axis version for the control of one element in the BC35 valve. On re-

    quest, extra microswitches will be available for the operation of furtherelements (up to 10 switches).

    ELECTRIC JOYSTICK WITH 2 AXIS AND MICROSWITCHES2 axes version for the control of two elements in the BC35 valve. On re-

    quest, extra microswitches will be available for the operation of further

    elements (up to 10 switches).

    VCC CONNECTION WIRESElectric wires to connect the joystick to the valve. Standard length 4.50

    meters.

    VCC E2S

    VCC E4S

    VCC E6S

    VCC E8S

    VCC E10S

    025105

    025106

    025107

    025108

    025109

    PC POWER CONNECTORConnects the joystick to the power source. Standard length 4.50 me-ters.

    PC 025110

    VC CONNECTORValve connector that allows kinds of wiring different from the usual.

    VC 025045

    ELECTRIC PROPORTIONAL JOYSTICK WITH 1 AXISElectric proportional joystick complete with electronic card. 1 axis ver-sion for the control of the TE RFPE DV Inlet. On request, extra micro-

    switches will be available for the operation of further elements (up to

    10 switches).

    JMP 2SJMP 4S

    JMP 6S

    JMP 8S

    JMP 10S

    023110023111

    023112

    023113

    023114

    BC35

  • 7/28/2019 Catalogo BC35

    16/16

    BRACKETS

    BRACKETS KIT

    560893

    TIE RODS KIT FOR STANDARD TE

    560067

    560207560208

    560209

    560210

    560062

    560063560064

    560065

    560066

    BC35/6

    BC35/7BC35/8

    BC35/9

    BC35/10

    BC35/1

    BC35/2BC35/3

    BC35/4

    BC35/5

    TIE RODS KIT FOR TE DV - TE RFPE DV

    560965

    560966

    560967

    560968

    560969

    560960

    560961

    560962

    560963

    560964

    BC35/6

    BC35/7

    BC35/8

    BC35/9

    BC35/10

    BC35/1

    BC35/2

    BC35/3

    BC35/4

    BC35/5

    CO CARRY OVERAllows the installation of another valve downstream from the rst. To be assem-bled on T2 port of the valve.

    CO G

    CO F

    832019

    832032

    CCP CLOSE CENTER PLUG Turns an open center circuit into a close center one.

    CCP G

    CCP F

    832017

    832033

    RVP RELIEF VALVE PLUG Replaces the relief valve in close center systems where the relief valveis not required.

    832018

    P T

    RVP

    PB RELIEF VALVE LOCK KIT Prevents users from altering the factory relief valve setting.

    560926PB

    ACCESSORIESBC35