Catalogo BC35
-
Upload
darko-miladinovic -
Category
Documents
-
view
217 -
download
0
Transcript of Catalogo BC35
-
7/28/2019 Catalogo BC35
1/16
BC35EDO
-
7/28/2019 Catalogo BC35
2/16
BC35
www.blbhydraulic.com2
LENGTH
PRESSURE
VACUUM
FLOW
FORCE
MASS
TIME
VOLUME
TEMPERATURE
TORQUE
POWER
SHAFT SPEED
FREQUENCY
DISPLACEMENT
VELOCITY
1 inch = 25.4 millimetre (mm)
1 pound per square inch (PSI) = 0.069 bar (gage)
1 inch of mercury (in Hg) = 0.034 bar (a value less
than 1.0 at 60 degrees Fahrenheit 1(F)
1 gallon per minute (GPM) = 3.785 litres per minute
(l/min)
1 gallon per minute (GPM) = 3785 cubic
centimetres per minute (cc/min)
1 poundf(Ibf) = 4.44 Newton (N)
1 poundm (Ibm) = 0.455 kilogram (Kg)
second (s)
1 US gallon (gal) = 3.785 litre (l)
1 US gallon (gal) = 3785 cubic centimetres (cc)
F = (1.8 C) + 32
1 poundfinch (Ibf - in.) = 0.1136 Newton metre (N
m) or joule
1 horsepower (HP) = 0.746 kilowatt (kW)
revolutions per minute (RPM)
1 cycle per second (cps) = 1 Hertz (Hz)
1 cubic inch per revolution (cu. in./rev.) = 16.4
cubic centimetres per revolution (cc/rev)
1 foot per second (fps) = 0.305 metre per second
(m/s)
1 millimetre (mm) = 0.0394 inch
1 bar (gage) = 14.493 pounds per square inch (PSI)
0.1 bar (a value less than 1.0) = 2.94 inches of
mercury (in Hg) at 15.6 degrees Celsius (C)
1 litre per minute (l/min) = 0.264 gallons per minute
(GPM)
1 cubic centimetre per minute (cc/min) = 0.000264
gallons per minute (GPM)
1 Newton (N) = 0.225 poundf(Ibf)
1 kilogram (kg) = 2.20 poundm (Ibm)
second (s)
1 litre (l) = 0.264 US gallon (gal)
1 cubic centimetre (cc) = 0.000264 US gallons (gal)
C = 0.556 (F - 32)
1 Newton metre (N m) or joule = 8.8 poundfinches
(Ibf - in.)
1 kilowatt (kW) = 1.34 horsepower (HP)
revolutions per minute (rev/min)
1 Hertz (Hz) = 1 cycle per second (cps)
1 cubic centimetre per revolution (cc/rev) = 0.061
cubic inches per revolution (cu. in./rev.)
1 metre per second (m/s) = 3.28 feet per second (fps)
NOTE: 1 cubic (cc) = 1 millilitre (ml) = 0.001 litre (l)
UNIT CONVERSION TABLE
-
7/28/2019 Catalogo BC35
3/16www.blbhydraulic.com 3
GENERAL INDICATIONS
TECHNICAL CHARACTERISTICS
DESIGNATION SAMPLE
TE INLETS
S EDO - V EDO STANDARD ELEMENTS
CF EDO - CFV EDO FLOW CONTROL ELEMENTS
RFS - RFSO FLOW CONTROL SECTIONS
RFP - RFPO FLOW CONTROL SECTIONS
P EDO - PV EDO PRIORITY ELEMENTS
R EDO - RV EDO RECUPERATION ELEMENTS
TU OUTLETS
ELECTRIC JOYSTICKS
ACCESSORIES
INDEX BC35
4
5
6
7
8
9
10
11
12
13
14
15
16
-
7/28/2019 Catalogo BC35
4/16www.blbhydraulic.com4
This booklet is meant to be a technical deepening on the BC35 directional control valve. Choice, use, maintenance and warrantyconditions of all BLB products are described in the BLB General Catalogue.
The BC35 sectional valve has been designed for the remote electric actuation of systems with x displacement pumps.
However, the installation of an auxiliary electro-valve (LSK) allows the utilization of the BC35 valve in systems with variable displa-
cement pumps (LS).
GENERAL INDICATIONSBC35
12345678
76
140
110 31
120
A
B
A
B
A
B
TP
45 35 4635
I
83
130
125
161L
279
Without relief valve Open center Close center
High pressure carry over (power beyond)
COT2 CCP
VLA
VLB
RVP
RVP
VLRVP
T T
PP
P2 P2
T T T
141
-
7/28/2019 Catalogo BC35
5/16www.blbhydraulic.com 5
BC35TECHNICAL CHARACTERISTICS
4-WAY / 3-POSITION SPOOL. Provides control of double-acting cylinders or bi-directional
hydraulic motors. In position 0 work ports are blocked.
3-WAY / 3-POSITION SPOOL. Provides control of single-acting cylinders or start and stop
of uni-directional hydraulic motors. In position 0 work port is blocked. B port is plugged.
4-WAY / 3-POSITION SPOOL, OPEN CENTER (MOTOR SPOOL). Provides control of dou-
ble acting cylinders or bi-directional hydraulic motors. Allows a cylinder to oat or a motor
to wheel free when the spool is in position 0. Work ports are open to the tank port when the
spool is in position 0.
DE
BE
AE
SPOOL TYPES
0 5
(1,3)
20
(5,2)
30
(7,9)
(PSI) bar
(218) 15
(145) 10
(73) 5
P T
1
P T
10
(2,6)
15
(3,9)
25
(6,5)
2
3
5
4
6
NOMINAL FLOW
MAX FLOW
NOMINAL PRESSURE
MAX PRESSURE ON PORTS
MAX PRESSURE ON TANK-LINE
30 l/min
35 l/min
200 bar
250 bar
15 bar
8 GPM
9,2 GPM
2900 PSI
3600 PSI
220 PSI
TECHNICAL CHARACTERISTICS
From A B to T
Pressure
Oil temperature
Oil viscosity
4 8 cc/min
100 bar
40 C
32 mm/s
INTERNAL OIL LEAKAGE
TESTING CONDITIONS
G (BSP)
F (UNF)
A - B
3/8
3/4-16
P
3/8
3/4-16
T
3/8
3/4-16
P2
3/8
3/4-16
T2
3/8
3/4-16
STANDARD THREADSBC35/1
BC35/2
BC35/3
BC35/4
...
NUMBEROF SECTIONS
91
126
161
196
...
(mm)
55
90
125
160
...
3,58
4,96
6,33
7,71
...
2,16
3,54
4,92
6,29
...
L
(inch) (mm) (inch)
I
ACTUATORS
MO...EDOCombined push-pull and manual actuator
PP A/B
0 5
(1,3)
20
(5,2)
30
(7,9)
(PSI) bar
(218) 15
(145) 10
(73) 5
1
10
(2,6)
15
(3,9)
25
(6,5)
23
54
6(290) 20
TA/B
numberofworkingsections
l/min
(GPM)
T
0 5
(1,3)
20
(5,2)
30
(7,9)
(PSI) bar
(218) 15
(145) 10
(73) 5
1
10
(2,6)
15
(3,9)
25
(6,5)
2
3
54
6
The BC35 sectional valve has the following features:
Possibility to have auxiliary valves on ports
Check valves on each section; Priority ow control sections (RFS, RFP);
Elements with integrated pressure compensated ow control (CF, CFV).
Thanks to its high versatility and modular structure, the BC35 valve can be used in simple and complex hydraulic systems, fullling
the most advanced requirements of the modern mobile machines.
-
7/28/2019 Catalogo BC35
6/16www.blbhydraulic.com6
DESIGNATION SAMPLEBC35
TYPE
OF VALVE
NUMBER
OF ELEMENTS
VOLTAGE
12 volt DC
24 volt DC
OUTLET OPTIONS
CO Carry over
CCP Close center plug
TYPE OF ELEMENT
S Standard element
VElement accepting valves on ports
P Priority element
PVPriority element accepting valves on portsR Recuperation element
RVRecuperation element accepting valves on ports
CF Element with compensated priority ow control
CFV Element with compensated priority ow control
accepting valves on ports
TYPE OF ACTUATOR
EDO Push-pull electric actuator
SPOOL TYPE
AE Double acting
BE Single acting
DE Motor spoolTYPE OF INLET RELIEF VALVE
U 90250 bar
K150300 bar
TYPE OF ELEMENT
S Standard element
VElement accepting valves on ports
P Priority element
PVPriority element accepting valves on portsR Recuperation element
RVRecuperation element accepting valves on ports
CF Element with compensated priority ow control
CFV Element with compensated priority ow control
accepting valves on ports
TYPE OF ACTUATOR
EDO Push-pull
electric actuator
SPOOL TYPE
AE Double actingBE Single acting
DE Motor spool
AUXILIARY VALVES ON PORTS
VL Main relief valve
VC Anticavitation
VLC Combined anticavitation
- Antishock valve
PRIORITY FLOW
CONTROL SECTION
RFS Exceeding ow
to the tank
RFP Exceeding ow
recuperated
INLET TYPE
DVDump valve
RFPE DVproportionally
controlled ow regulator
RVP Relief valve plug
TYPE OF THREADS
G British standard parallel
F American standard UNF
APort
B Port
P Pump connection
P2 Pump connection
RVP Relief valve plug
DVDump valve
DVP Dump valve plug
EDO Push-pull electric actuator
MO Manual actuator
VL Main relief valve
VLABAntishock valves
VLC Antishock and anticavitation valve
VC Anticavitation valve
T Tank connection
T2 Tank connection
CCP Close center plug
CO Carry over
MANDATORY FIELD
OPTIONAL FIELD
LEGEND
T
T
VLA
VLB
P
P2
T
VL
BC35/3 12 DV GK /S MO AE EDO/RFS/V MO AE EDO VLAB/CO
TYPE OF
ACTUATOR
MO Manual
actuator
TYPE OF
ACTUATOR
MO Manual
actuator
-
7/28/2019 Catalogo BC35
7/16www.blbhydraulic.com 7
BC35TE RFPE DV GU 12
BC35TE RFPE DV GU 24
BC35TE RFPE DV GK 12
BC35TE RFPE DV GK 24
BC35TE RFEP DV FU 12
BC35TE RFEP DV FU 24
BC35TE RFEP DV FK 12
BC35TE RFEP DV FK 24
805135
805193
805194
805195
805196
805197
805198
805199
TE INLETS BC35
BC35TE DV GU12
BC35TE DV GU24
BC35TE DV GK12BC35TE DV GK24
BC35TE DV FU12
BC35TE DV FU24
BC35TE DV FK12
BC35TE DV FK24
805186
805139
805187805188
805189
805190
805191
805192
TE DV
2,5 kg
P
P2
T
VL
TE RFPE DV
3,1 kg
BC35TE GU
BC35TE GK
BC35TE FU
BC35TE FK
805027
805057
805024
805032
TE
0,9 kg
P
P2
T
VL
DV dump valve prevents the unwanted or accidental use of the directional control valve, con-
necting the pump ow to the tank.
The BC35TE RFPE DV inlet features a dump valve that prevents the unwanted or accidental use of the directional control valve,
connecting the pump ow to the tank.
It also features a logic valve (ELP/30) and a proportionally controlled ow regulator (PSS/30).The combination of these two elements allows the proportional regulation of the ow going to following elements, connecting to the
tank the exceeding ow not needed.
ELP/30
P
P2
T
VL
PSS/30
-
7/28/2019 Catalogo BC35
8/16www.blbhydraulic.com8
BC35
STANDARD ELEMENT STANDARD ELEMENT
ACCEPTING
VALVES
ON PORTS
BC35S 12 G /MO AE EDO/
BC35S 24 G /MO AE EDO/
BC35S 12 F /MO AE EDO/
BC35S 24 F /MO AE EDO/
807638
807640
807650
807888
BC35V 12 G /MO AE EDO RVPAB/
BC35V 24 G /MO AE EDO RVPAB/
BC35V 12 F /MO AE EDO RVPAB/
BC35V 24 F /MO AE EDO RVPAB/
807644
807897
807898
807899
BC35S 12 G /MO BE EDO/
BC35S 24 G /MO BE EDO/
BC35S 12 F /MO BE EDO/BC35S 24 F /MO BE EDO/
807889
807890
807891807892
BC35V 12 G /MO BE EDO RVPAB/
BC35V 24 G /MO BE EDO RVPAB/
BC35V 12 F /MO BE EDO RVPAB/
BC35V 24 F /MO BE EDO RVPAB/
807904
807905
807906807907
BC35S 12 G /MO DE EDO/
BC35S 24 G /MO DE EDO/
BC35S 12 F /MO DE EDO/
BC35S 24 F /MO DE EDO/
807893
807894
807895
807896
BC35V 12 G /MO DE EDO RVPAB/
BC35V 24 G /MO DE EDO RVPAB/
BC35V 12 F /MO DE EDO RVPAB/
BC35V 24 F /MO DE EDO RVPAB/
807912
807913
807914
807915
BC35V 12 G /MO AE EDO VLAB/
BC35V 24 G /MO AE EDO VLAB/
BC35V 12 F /MO AE EDO VLAB/
BC35V 24 F /MO AE EDO VLAB/
807900
807901
807902
807903
BC35V 12 G /MO BE EDO VLAB/
BC35V 24 G /MO BE EDO VLAB/
BC35V 12 F /MO BE EDO VLAB/
BC35V 24 F /MO BE EDO VLAB/
807908
807909
807910
807911
VL valves on ports A and B are type U.
Standard setting 140 bar.
BC35V 12 G /MO DE EDO VLAB/
BC35V 24 G /MO DE EDO VLAB/
BC35V 12 F /MO DE EDO VLAB/
BC35V 24 F /MO DE EDO VLAB/
807916
807917
807918
807919
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
Double acting Double acting
Single acting Single acting
Motor spool Motor spool
S EDO - V EDO STANDARD ELEMENTS
S V2,2 kg 2,7 kg
P
0
2
1
B
A
A
P
0
2
1
B
A
A
RVP
RVP
P
0
2
1
B
A
B A
P
0
2
1
B
A
B A
RVP
RVP
B
P
0
2
1
B
A
A
P
0
2
1
B
A
B A
RVP
RVP
-
7/28/2019 Catalogo BC35
9/16www.blbhydraulic.com 9
CF EDO - CFV EDO FLOW CONTROL ELEMENTS
BC35CF 12 G /MO AE EDO/
BC35CF 24 G /MO AE EDO/
BC35CF 12 F /MO AE EDO/
BC35CF 24 F /MO AE EDO/
807920
807921
807922
807923
BC35CFV 12 G /MO AE EDO RVPAB/
BC35CFV 24 G /MO AE EDO RVPAB/
BC35CFV 12 F /MO AE EDO RVPAB/
BC35CFV 24 F /MO AE EDO RVPAB/
BC35CFV 12 G /MO AE EDO VLAB/
BC35CFV 24 G /MO AE EDO VLAB/
BC35CFV 12 F /MO AE EDO VLAB/
BC35CFV 24 F /MO AE EDO VLAB/
807932
807933
807934
807935
807936
807937
807938
807939
BC35CF 12 G /MO BE EDO/
BC35CF 24 G /MO BE EDO/
BC35CF 12 F /MO BE EDO/
BC35CF 24 F /MO BE EDO/
807924
807925
807926
807927
BC35CF 12 G /MO DE EDO/
BC35CF 24 G /MO DE EDO/
BC35CF 12 F /MO DE EDO/
BC35CF 24 F /MO DE EDO/
807928
807929
807930
807931
BC35CFV 12 G /MO BE EDO RVPAB/
BC35CFV 24 G /MO BE EDO RVPAB/
BC35CFV 12 F /MO BE EDO RVPAB/
BC35CFV 24 F /MO BE EDO RVPAB/
BC35CFV 12 G /MO BE EDO VLAB/
BC35CFV 24 G /MO BE EDO VLAB/
BC35CFV 12 F /MO BE EDO VLAB/
BC35CFV 24 F /MO BE EDO VLAB/
807940
807941
807942
807943
807944
807945
807946
807947
BC35CFV 12 G /MO DE EDO RVPAB/
BC35CFV 24 G /MO DE EDO RVPAB/
BC35CFV 12 F /MO DE EDO RVPAB/
BC35CFV 24 F /MO DE EDO RVPAB/
BC35CFV 12 G /MO DE EDO VLAB/
BC35CFV 24 G /MO DE EDO VLAB/
BC35CFV 12 F /MO DE EDO VLAB/
BC35CFV 24 F /MO DE EDO VLAB/
807948
807949
807950
807951
807952
807953
807954
807955
CF
FLOW CONTROL
ELEMENT
ACCEPTING
VALVES
ON PORTS
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.NOTE: After a CF or CFV the
frst element must be a R type
CFV
Double acting
Single acting
Motor spool Motor spool
Single acting
Double acting
FLOW CONTROL ELEMENT
CF and CFV elements integrate
a pressure compensated ow
control that allows the external
regulation of the ow inside theelements themselves and recu-
perates the exceeding ow (EF)
for the following elements.
2,6 kg 3,2 kg
P0
2
1
B
A
B A B A
P
0
2
1
B
A
RVP
RVP
A
P
0
2
1
A
RVP
RVP
P
0
2
1
A
A
B A
P
0
2
1
B
A
RVP
RVP
P
0
2
1
B
A
B A
BC35
-
7/28/2019 Catalogo BC35
10/16www.blbhydraulic.com10
The pressure compensated ow control section RFS, divides the
ow in two channels: the priority ow (PF) channel, adjustable
with the external knob, and the exceeding ow (EF) channel that
goes to tank. Elements preceding RFS sections receive the fullpump ow whereas the elements following RFS sections receive
just the ow requested and settled. In order to prevent undesired
heating in the system, the RFS section works only when one ormore of the following sections are operated. The RFS section
can be combined with all standard elements.
BC35 RFS
BC35 RFSO
835078
835081
HORIZONTALVERTICAL
EXAMPLE The motor (A) is fed by the whole ow of the pump. The cylinders (C, D) downstream the ow control element (RFS) are fed only by the priority ow (PF)
which is adjustable through the ow control knob on the element. The excess ow goes to tank.
RFS - RFSO FLOW CONTROL SECTIONSBC35
1,2 kg1,2 kg
T2
T
T
VL
P2
P
TE S RFS S S TU
Priority ow
Excessfow
-
7/28/2019 Catalogo BC35
11/16www.blbhydraulic.com 11
RFP - RFPO FLOW CONTROL SECTIONS BC35
BC35 RFP
BC35 RFPO
835079
835122
The pressure compensated ow control section RFP, divides
the ow in two channels: the rst channel receives the priority
ow (PF) (adjustable with the external knob) and feeds one or
more Priority elements (P, PV); the second channel receives
the exceeding ow (EF) and feeds one ore more Recuperationelements (R, RV) which follow the priority ones. RFP sections,
have to be followed by one or more priority elements (P, PV);Priority elements have to be followed by one or more Recupe-
ration elements (R, RV). In order to prevent undesired heating
in the system the RFP section works only when one or more of
the Priority sections are operated. The installation of an RFPsection, allows the contemporaneous operation of one Priority
element and one Recuperation element which will work at diffe-
rent ows and pressures without interfering one with the other.
When no Priority section is operated, the Recuperation elements
get the full pump ow.
HORIZONTALVERTICAL
EXAMPLEThe motors (A, B) are fed by the priority ow (PF) which is adjustable through the ow control knob on the element. The cylinders (C, D) are fed by the whole owof the pump when singly actuated. When a cylinder and a motor are simultaneously actuated, the motor is fed by the priority ow (PF) and the cylinder by the exceeding ow
(EF). If a cylinder is actuated while a motor is in work, this last will not vary its rotation speed.
1,2 kg1,2 kg
TE RFP P
T
T
T
VL
P2
P
P R S TU
Priority ow
Excess ow
-
7/28/2019 Catalogo BC35
12/16www.blbhydraulic.com12
BC35PV 12 G /MO BE EDO RVPAB/
BC35PV 24 G /MO BE EDO RVPAB/
BC35PV 12 F /MO BE EDO RVPAB/BC35PV 24 F /MO BE EDO RVPAB/
807976
807977
807978807979
BC35PV 12 G /MO DE EDO RVPAB/
BC35PV 24 G /MO DE EDO RVPAB/
BC35PV 12 F /MO DE EDO RVPAB/
BC35PV 24 F /MO DE EDO RVPAB/
807984
807985
807986
807987
BC35P 12 G /MO AE EDO/
BC35P 24 G /MO AE EDO/
BC35P 12 F /MO AE EDO/
BC35P 24 F /MO AE EDO/
807956
807957
807958
807959
BC35P 12 G /MO BE EDO/
BC35P 24 G /MO BE EDO/
BC35P 12 F /MO BE EDO/BC35P 24 F /MO BE EDO/
807960
807961
807962807963
BC35P 12 G /MO DE EDO/
BC35P 24 G /MO DE EDO/
BC35P 12 F /MO DE EDO/
BC35P 24 F /MO DE EDO/
807964
807965
807966
807967
807968
807969
807970
807971
BC35PV 12 G /MO AE EDO RVPAB/
BC35PV 24 G /MO AE EDO RVPAB/
BC35PV 12 F /MO AE EDO RVPAB/
BC35PV 24 F /MO AE EDO RVPAB/
PRIORITY ELEMENT PRIORITY
ELEMENT
ACCEPTING
VALVES ON
PORTS
807972
807973
807974
807975
BC35PV 12 G /MO AE EDO VLAB/
BC35PV 24 G /MO AE EDO VLAB/
BC35PV 12 F /MO AE EDO VLAB/
BC35PV 24 F /MO AE EDO VLAB/
807980
807981
807982
807983
BC35PV 12 G /MO BE EDO VLAB/
BC35PV 24 G /MO BE EDO VLAB/
BC35PV 12 F /MO BE EDO VLAB/
BC35PV 24 F /MO BE EDO VLAB/
807988
807989
807990
807991
BC35PV 12 G /MO DE EDO VLAB/
BC35PV 24 G /MO DE EDO VLAB/
BC35PV 12 F /MO DE EDO VLAB/
BC35PV 24 F /MO DE EDO VLAB/
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
Double acting
Single acting
Motor spool
Double acting
Single acting
Motor spool
P PV
P EDO - PV EDO PRIORITY ELEMENTSBC35
P elements use the priority ow regulated by
the RFP sections. They have to be installed
after an RFP section.
2,2 kg 2,7 kg
P
0
2
1
B
A
B A
RVP
RVP
P
0
2
1
B
A
A
RVP
RVP
P
0
2
1
B
A
A
B
P
0
2
1
B
A
A
P
0
2
1
B
A
B A
P
0
2
1
B
A
B A
RVP
RVP
-
7/28/2019 Catalogo BC35
13/16www.blbhydraulic.com 13
R EDO - RV EDO RECUPERATION ELEMENTS BC35
BC35R 12 G /MO AE EDO/
BC35R 24 G /MO AE EDO/
BC35R 12 F /MO AE EDO/
BC35R 24 F /MO AE EDO/
807992
807993
807994
807995
BC35R 12 G /MO BE EDO/
BC35R 24 G /MO BE EDO/
BC35R 12 F /MO BE EDO/BC35R 24 F /MO BE EDO/
807996
807997
807998807999
BC35R 12 G /MO DE EDO/
BC35R 24 G /MO DE EDO/
BC35R 12 F /MO DE EDO/
BC35R 24 F /MO DE EDO/
808001
808002
808003
808004
BC35RV 12 G /MO DE EDO RVPAB/
BC35RV 24 G /MO DE EDO RVPAB/
BC35RV 12 F /MO DE EDO RVPAB/
BC35RV 24 F /MO DE EDO RVPAB/
808021
808022
808023
808024
BC35RV 12 G /MO BE EDO RVPAB/
BC35RV 24 G /MO BE EDO RVPAB/
BC35RV 12 F /MO BE EDO RVPAB/BC35RV 24 F /MO BE EDO RVPAB/
808013
808014
808015808016
BC35RV 12 G /MO AE EDO RVPAB/
BC35RV 24 G /MO AE EDO RVPAB/
BC35RV 12 F /MO AE EDO RVPAB/
BC35RV 24 F /MO AE EDO RVPAB/
808005
808006
808007
808008
BC35RV 12 G /MO AE EDO VLAB/
BC35RV 24 G /MO AE EDO VLAB/
BC35RV 12 F /MO AE EDO VLAB/
BC35RV 24 F /MO AE EDO VLAB/
808009
808010
808011
808012
BC35RV 12 G /MO BE EDO VLAB/
BC35RV 24 G /MO BE EDO VLAB/
BC35RV 12 F /MO BE EDO VLAB/
BC35RV 24 F /MO BE EDO VLAB/
808017
808018
808019
808020
BC35RV 12 G /MO DE EDO VLAB/
BC35RV 24 G /MO DE EDO VLAB/
BC35RV 12 F /MO DE EDO VLAB/
BC35RV 24 F /MO DE EDO VLAB/
808025
808026
808027
808028
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
VL valves on ports A and B are type U.
Standard setting 140 bar.
Double acting
Single acting
Motor spool
Double acting
Single acting
Motor spool
RECUPERATION ELEMENT RECUPERATION
ELEMENT
ACCEPTING
VALVES ON
PORTS
R RV
R elements use the exceeding ow coming
from an RFP section. They have to be in-
stalled only after one or more P elements.
2,2 kg 2,7 kg
P
0
2
1
B
A
B A
RVP
RVP
B
P
0
2
1
B
A
A
P
0
2
1
B
A
A
P
0
2
1
B
A
A
RVP
RVP
P
0
2
1
B
A
B A
P
0
2
1
B
A
B A
RVP
RVP
-
7/28/2019 Catalogo BC35
14/16www.blbhydraulic.com14
TU OUTLETSBC35
TU
TU
OUTLET
OUTLET
0,8 kg
1,9 kg
T
T
TB
P
0
2
1
B
A
A
T
T
BC35TU 12 KEO G
BC35TU 24 KEO G
BC35TU 12 KEO F
BC35TU 24 KEO F
805134
805184
805185
805186
BC35TU G
BC35TU F
805028
805025
BC35TE KEO outlet features an electric 3 ways valve. Connected to a special element, thisvalve, when operated, connects A and B ports to tank, allowing a cylinder or a motor to oat.
-
7/28/2019 Catalogo BC35
15/16www.blbhydraulic.com 15
ELECTRIC JOYSTICKS
ELECTRIC JOYSTICKS
POWER CONNECTOR
CONNECTION WIRES
JME 2S
JME 4S
JME 6S
JME 8S
JME 10S
023065
023066
023067
023068
023069
JSE 2S
JSE 4S
JSE 6S
JSE 8S
JSE 10S
023062
023063
023061
023060
023064
VC CONNECTOR
ELECTRIC JOYSTICK WITH 1 AXIS AND MICROSWITCHES1 axis version for the control of one element in the BC35 valve. On re-
quest, extra microswitches will be available for the operation of furtherelements (up to 10 switches).
ELECTRIC JOYSTICK WITH 2 AXIS AND MICROSWITCHES2 axes version for the control of two elements in the BC35 valve. On re-
quest, extra microswitches will be available for the operation of further
elements (up to 10 switches).
VCC CONNECTION WIRESElectric wires to connect the joystick to the valve. Standard length 4.50
meters.
VCC E2S
VCC E4S
VCC E6S
VCC E8S
VCC E10S
025105
025106
025107
025108
025109
PC POWER CONNECTORConnects the joystick to the power source. Standard length 4.50 me-ters.
PC 025110
VC CONNECTORValve connector that allows kinds of wiring different from the usual.
VC 025045
ELECTRIC PROPORTIONAL JOYSTICK WITH 1 AXISElectric proportional joystick complete with electronic card. 1 axis ver-sion for the control of the TE RFPE DV Inlet. On request, extra micro-
switches will be available for the operation of further elements (up to
10 switches).
JMP 2SJMP 4S
JMP 6S
JMP 8S
JMP 10S
023110023111
023112
023113
023114
BC35
-
7/28/2019 Catalogo BC35
16/16
BRACKETS
BRACKETS KIT
560893
TIE RODS KIT FOR STANDARD TE
560067
560207560208
560209
560210
560062
560063560064
560065
560066
BC35/6
BC35/7BC35/8
BC35/9
BC35/10
BC35/1
BC35/2BC35/3
BC35/4
BC35/5
TIE RODS KIT FOR TE DV - TE RFPE DV
560965
560966
560967
560968
560969
560960
560961
560962
560963
560964
BC35/6
BC35/7
BC35/8
BC35/9
BC35/10
BC35/1
BC35/2
BC35/3
BC35/4
BC35/5
CO CARRY OVERAllows the installation of another valve downstream from the rst. To be assem-bled on T2 port of the valve.
CO G
CO F
832019
832032
CCP CLOSE CENTER PLUG Turns an open center circuit into a close center one.
CCP G
CCP F
832017
832033
RVP RELIEF VALVE PLUG Replaces the relief valve in close center systems where the relief valveis not required.
832018
P T
RVP
PB RELIEF VALVE LOCK KIT Prevents users from altering the factory relief valve setting.
560926PB
ACCESSORIESBC35