09131A Addcomm bestek - Sheet - 52-01A - … · kolom Let op: onderstempelen vloer niet nodig...

1
1 2 3 4 5 A B C D E F G H I J K L M K1 K2 K3 K4 K5 K6 K7 3000 5600 5600 3000 2600 5600 5600 5800 5800 5800 5800 5800 3600 3600 3600 3600 3600 3600 HE400B HE550B IPE300 doorgaand HE550B HE550B K250x150x8 in vloer K250x150x8 in vloer K250x150x8 in vloer +10700 250 K160x8 50mm onder vloer K160x8 50mm onder vloer K160x8 50mm onder vloer K160x8 50mm onder vloer HE140B HE140B K140x6 HE140B K140x6 HE140B K140x6 HE140B HE140B HE320B HE320B niet dragend HE320B HE320B HE320B HE320B K300x12.5 K300x12.5 K300x12.5 Bordes +..... IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand IPE400 doorgaand HE140A HE140A HE140A HE140A HE140A doorgaand K80x4 K80x4 K80x4 K80x4 K80x4 K120x5 K120x5 K120x5 K120x5 K120x5 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 K80x4 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 L80x8 Afschot richting 16mm/m1 Afschot richting 16mm/m1 Afschot richting 16mm/m1 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 HE240B HE240B HE240B HE240B HE320A Onderslag doorgaand 60000 HE320A onderslag doorgaand K250x150x8 in vloer HE140B HE200A HE240B * * * * * * * * * * * * * * * * * Zeeg 60mm Zeeg 60mm Zeeg 60mm Zeeg 60mm 5400 5400 5400 5400 UNP 180 K60x4 K60x4 K60x4 K60x4 HE180B HE180B HE180B HE180B HE180B K60x4 K60x4 UNP 180 UNP 180 HE180A UNP 180 HE180A UNP 180 HE180A UNP 180 HE180A K100x4 K100x4 K100x4 Houten balklaag 46x121mm hoh 600mm Gearceerde deel sneeuwophoping. mv mv mv mv mv mv HE180B HE180B HE180B HE180B HE180B HE180B HE140B HE140B Wa Ì36 Wa Ì36 mv 60x6 60x6 60x6 60x6 Houten balklaag 59x156mm hoh 600mm Houten balklaag 59x156mm hoh 600mm IPE180 K80x4 IPE180 K80x4 IPE180 K80x4 IPE180 mv mv mv S-22 1 4 7 10 13 15 A A C C F F H H J J L L N N P P R R T T K1 K4 K7 K10 K13 K16 K19 K22 Gaffelverbinding. Staalprofiel Staalprofiel Kolom op de vloer. Kolom onder de vloer. h. 30 b. Aanzicht rechte overlaat. = rechte overlaat ...x100 (bxh) in mm bk dakbedekking 30 Aanzicht ronde steekafvoer. = ronde steekafvoer Ì.... in mm bk dakbedekking Overspanningsrichting Stalen dakplaten, h=106mm. Stalen dakplaten fungeren als kipsteun. Stalen dakplaten in verband leggen. Tpv sneeuwophoping dubbele stalen dakplaten toepassen Windverbanden in gevel / wand, 2x Willems anker Ì24 (Wa Ì24) tenzij anders vermeld. * Hamerkop sparing. Overspanningsrichting kanaalplaatvloer d=200mm met 50mm gewapende druklaag min. wapening druklaag: ▄8-150. Veranderlijke belasting: 3 kN/m2. mv Moment vaste verbinding tussen hoofdliggers / profielen. Alle aansluitingen van kokers met hoofdliggers uitvoeren als gaffelverbinding. (zie detail) Afschot 16mm/m1, LET OP zegen zijn exclusief afschot. Staalverbindingen dienen door derden berekend te worden. Trappen, bordessen en balustaden door derden. Belasting uit trappen, installaties en niet dragende wanden op vloer rekenen. Oplegmateriaal kanaalplaatvloer volgens opgave leverancier kanaalplaat. Hulpstaal tbv installaties en uitvoering / montage door derden. 1x Demu 3010-M16x750 + moer per sleufsparing in kanaalplaatvloer kolom kolom ligger 100 1x Æ12 lang 1500mm per sleufsparing in kanaalplaatvloer 1 sleufsparing per kanaalplaatelement Principe randdetail sleufsparing Principe middendetail sleufsparing geintregeerde ligger 1 sleufsparing per kanaalplaatelement voldoende stortsparingen aanbrengen Schotje 100x100 t=10 hoh 1200. niet tpv sleufsparingen. kolom Let op: onderstempelen vloer niet nodig indien de kanaalplaten om- en om worden gelegd. 1x Demu 4010-M16 + moer per hamerkopsparing kolom kolom ligger hamerkopsparing in ka.pl.vloer aantal en positie n.t.b. Principe randdetail hamerkopsparing 2 Æ12 lang 500 2e kanaal 600 JVZ Raadgevend Ingenieursburo bv E-mail [email protected] Website www.jvz.nl Nijmegen St. Annastraat 283 Postbus 31180, 6503 CD Nijmegen T 024-3734222 F 024-3734899 Deventer Hanzeweg 19057 Postbus 26, 7400 AA Deventer T 0570-629100 F 0570-625252 tekeningnummer: projectnummer: schaal: constructeur: tekenaar: afmeting: aannemer architect principaal onderdeel project datum omschrijving wijzigingen gezien a b c d e f g projectleider: - initialen paraaf gecontroleerd initialen paraaf getekend initialen paraaf 09 131A NIEUWBOUW BEDRIJFSPAND TE AMERSFOORT A. Strobos E. Gorkink M. Wesseling A0 Smink Beheer B.V. Nijkerk 033 2458486 Ebbens architecten Epe 0578 613007 Dijkham bouw 52-01A 1:100 STAALCONSTRUCTIE 1e VERDIEPING KANTOOR, STAALCONSTRUCTIE DAK HAL DEEL A 29-01-2010 BESTEK afmeting en positie zie tekening Ebbens afmeting en positie zie tekening Ebbens - RENVOOI STAALCONSTRUCTIE - Staalkwaliteit walsprofielen S235 JR Staalkwaliteit kokerprofielen S275 JOH Staalkwaliteit buisprofielen S235 JRH Boutkwaliteit 8.8 Ankerkwaliteit 4.6 Lassen a min.= 4mm of halve plaatdikte Lassen waar nodig voorbewerken als 1/2v-las Staalkwaliteit draadstangen S355 JR (tenzij anders op tekening aangegeven) Hout soort Sterkteklasse Klimaatklasse Europees of Scandinavisch vuren (binnen, normaal) (buiten, onder dak) RENVOOI GEZAAG D HOUT C 18 Brandveiligheid: - Hal (rechts van as E t/m as T): geen eisen aan brandwerendheid mbt bezwijken ivm toepassing sprinklerinstallatie, eea volgens rapport Sprinkler advies dd. 07-12-2009. - Kantoor (tussen as A en E vanaf begane grondvloer t/m dak): brandwerendheidseis van 60min mbt bezwijken, eea volgens rapport Sprinkler advies dd. 07-12-2009. Derhalve gehele staalconstructie kantoor ivm deze eis 60min brandwerend bekleden / behandelen, inclusief stabiliteitsvoorzieningen. Uitzonderingen: staal tbv glazenwas balkons en luifels. uitkraging bij as K1. Kolommen K100x4 bij as B en E.

Transcript of 09131A Addcomm bestek - Sheet - 52-01A - … · kolom Let op: onderstempelen vloer niet nodig...

Page 1: 09131A Addcomm bestek - Sheet - 52-01A - … · kolom Let op: onderstempelen vloer niet nodig indien de kanaalplaten om- en om worden gelegd. 1x Demu 4010-M16 + moer per hamerkopsparing

1

2

3

4

5

A B C D E F G H I J K L M

K1

K2

K3

K4

K5

K6

K7

3000 5600 5600 3000 2600 5600 5600 5800 5800 5800 5800 5800

3600

3600

3600

3600

3600

3600

HE400B

HE550B

IPE3

00 d

oorg

aand

HE550B

HE550B

K250

x150

x8 in

vlo

erK2

50x1

50x8

in v

loer

K250

x150

x8 in

vlo

er

+10700 250

K160

x8 5

0mm

ond

er v

loer

K160

x8 5

0mm

ond

er v

loer

K160

x8 5

0mm

ond

er v

loer

K160

x8 5

0mm

ond

er v

loer

HE140B HE140B

K140x6HE140B

K140x6HE140B

K140x6HE140B

HE140B

HE320B

HE320Bniet dragend

HE320B

HE320B

HE320B

HE320B K300x12.5

K300x12.5

K300x12.5

Bord

es+.

....

IPE400 doorgaandIPE400 doorgaand

IPE400 doorgaandIPE400 doorgaand

IPE400 doorgaandIPE400 doorgaand

IPE400 doorgaandIPE400 doorgaand

HE1

40A

HE1

40A

HE1

40A

HE1

40A

HE140A doorgaand

K80x

4K8

0x4

K80x

4K8

0x4

K80x

4

K120

x5K1

20x5

K120

x5K1

20x5

K120

x5

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4K8

0x4

K80x

4K8

0x4

K80x

4

K80x

4K8

0x4

K80x

4

K80x

4K8

0x4

K80x

4

K80x

4

K80x

4

K80x

4

K80x

4

L80x8

L80x8

L80x

8

L80x

8

L80x8

L80x8

L80x

8L8

0x8

L80x8

L80x8

L80x8

L80x

8

L80x

8

L80x

8

L80x

8

L80x

8

L80x8

L80x8

Afschot richting 16mm/m1Afschot richting 16mm/m1Afschot richting 16mm/m1

IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330 IPE330

IPE330

IPE330

IPE330

IPE330

HE240B

HE240BHE240B

HE240B

HE3

20A

Ond

ersl

ag d

oorg

aand

60000

HE3

20A

onde

rsla

g do

orga

and

K250

x150

x8 in

vlo

er

HE140B

HE200A

HE2

40B

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

Zeeg 60mm

Zeeg 60mm

Zeeg 60mm

Zeeg 60mm

5400

5400

5400

5400

UNP 180

K60x4 K60x4 K60x4 K60x4

HE1

80B

HE1

80B

HE1

80B

HE1

80B

HE1

80B

K60x4 K60x4

UN

P 18

0U

NP

180

HE1

80A

UN

P 18

0H

E180

AU

NP

180

HE1

80A

UN

P 18

0H

E180

A

K100x4

K100x4

K100x4

Houten balklaag46x121mm hoh 600mm

Gearceerde deelsneeuwophoping.

mvmvmvmvmvmv

HE180B HE180B HE180B HE180B HE180B HE180B

HE140B HE140B

Wa Ì36Wa Ì36mv

▀ 60x6

▀ 60x6

▀ 60x6

▀ 60x6Houten balklaag59x156mmhoh 600mm

Houten balklaag59x156mmhoh 600mm

IPE180

K80x4

IPE180

K80x4

IPE180

K80x4

IPE180

mv

mv

mv

S-22

1

4

7

10

13

15

A

A

C

C

F

F

H

H

J

J

L

L

N

N

P

P

R

R

T

T

K1

K4

K7

K10

K13

K16

K19

K22

Gaffelverbinding.

StaalprofielStaalprofiel

Kolom op de vloer.Kolom onder de vloer.

h.30

b.

Aanzicht rechte overlaat.

= rechte overlaat ...x100 (bxh) in mm

bkdakbedekking

30

Aanzicht ronde steekafvoer.

= ronde steekafvoer Ì.... in mm

bkdakbedekking

Overspanningsrichting Stalen dakplaten, h=106mm. Stalen dakplaten fungerenals kipsteun. Stalen dakplaten in verband leggen. Tpv sneeuwophoping dubbele stalen dakplaten toepassen

Windverbanden in gevel / wand, 2x Willems anker Ì24 (Wa Ì24) tenzijanders vermeld.

* Hamerkop sparing.

Overspanningsrichting kanaalplaatvloer d=200mm met 50mm gewapende druklaagmin. wapening druklaag: ▄8-150. Veranderlijke belasting: 3 kN/m2.

mvMoment vaste verbinding tussen hoofdliggers / profielen.

Alle aansluitingen van kokers met hoofdliggers uitvoeren als gaffelverbinding. (zie detail)

Afschot 16mm/m1, LET OP zegen zijn exclusief afschot.

Staalverbindingen dienen door derden berekend te worden.

Trappen, bordessen en balustaden door derden.Belasting uit trappen, installaties en niet dragende wanden op vloer rekenen.

Oplegmateriaal kanaalplaatvloer volgens opgave leverancier kanaalplaat.

Hulpstaal tbv installaties en uitvoering / montage door derden.

1x Demu 3010-M16x750 + moerper sleufsparing in kanaalplaatvloer

kolom

kolom

ligger

100

1x Æ12 lang 1500mmper sleufsparing in kanaalplaatvloer

1 sleufsparing per kanaalplaatelement

Principe randdetail sleufsparing

Principe middendetail sleufsparing geintregeerde ligger

1 sleufsparing per kanaalplaatelement

voldoende stortsparingen aanbrengen

Schotje 100x100 t=10 hoh 1200.niet tpv sleufsparingen.

kolom

Let op: onderstempelen vloer niet nodig indiende kanaalplaten om- en om worden gelegd.

1x Demu 4010-M16 + moerper hamerkopsparing

kolom

kolom

ligger

hamerkopsparing in ka.pl.vloeraantal en positie n.t.b.

Principe randdetail hamerkopsparing

2 Æ12 lang 500

2e k

anaa

l60

0

JVZ Raadgevend Ingenieursburo bv E-mail [email protected] Website www.jvz.nl

Nijmegen St. Annastraat 283 Postbus 31180, 6503 CD Nijmegen T 024-3734222 F 024-3734899

Deventer Hanzeweg 19057 Postbus 26, 7400 AA Deventer T 0570-629100 F 0570-625252

tekeningnummer:

projectnummer:

schaal:

constructeur:

tekenaar:

afmeting:

aannem

er

arch

itec

tprinci

paa

londer

dee

lpro

ject

datum omschrijving wijzigingen gezien

a

b

c

d

e

f

g

projectleider:

-

initialen paraaf

gecontroleerd

initialen paraaf

getekend

initialen paraaf

09 131A

NIEUWBOUW BEDRIJFSPAND TE AMERSFOORT

A. Strobos

E. Gorkink

M. Wesseling

A0

Smink Beheer B.V.

Nijkerk

033 2458486

Ebbens architecten

Epe

0578 613007

Dijkham bouw

52-01A

1:100

STAALCONSTRUCTIE 1e VERDIEPING KANTOOR,STAALCONSTRUCTIE DAK HAL DEEL A

29-01-2010

BESTEK

afmeting en positie zie tekening Ebbens

afmeting en positie zie tekening Ebbens

- RENVOOI STAALCONSTRUCTIE -

Staalkwaliteit walsprofielen S235 JRStaalkwaliteit kokerprofielen S275 JOHStaalkwaliteit buisprofielen S235 JRH

Boutkwaliteit 8.8Ankerkwaliteit 4.6Lassen a min.= 4mm of halve plaatdikteLassen waar nodig voorbewerken als 1/2v-las

Staalkwaliteit draadstangen S355 JR

(tenzij anders op tekening aangegeven)

Hout soortSterkteklasseKlimaatklasse

Europees of Scandinavisch vuren

(binnen, normaal)(buiten, onder dak)

RENVOOI GEZAAG D HOUT

C 18

Brandveiligheid:- Hal (rechts van as E t/m as T): geen eisen aan brandwerendheid mbt bezwijken ivm toepassing sprinklerinstallatie, eea volgens rapport Sprinkler advies dd. 07-12-2009.- Kantoor (tussen as A en E vanaf begane grondvloer t/m dak): brandwerendheidseis van 60min mbt bezwijken, eea volgens rapport Sprinkler advies dd. 07-12-2009. Derhalve gehele staalconstructie kantoor ivm deze eis 60min brandwerend bekleden / behandelen, inclusief stabiliteitsvoorzieningen. Uitzonderingen: staal tbv glazenwas balkons en luifels.